099600 - High-Performance Coatings.pdf

PDF 43 KB Posted

Attached to
Construction Contract for the Customs and Border Protection Seized Cargo Facility Federal contract opportunity
Solicitation number
47PF0020R0040
Issued by
General Services Administration Public Buildings Service Region 5

About this file

This document provides details for a federal construction contract opportunity with the General Services Administration for the Customs and Border Protection Seized Cargo Facility project in Detroit, Michigan. The contract is set aside for 8(a) businesses and will be awarded using best value source selection procedures. The construction budget is between $1 million to $5 million. Services required include renovation of existing office spaces, construction of a new annex and high security vault, and site improvements. The selected contractor will be responsible for precast concrete structures, construction logistics on a constrained site, selective demolition, tenant improvements, security and IT infrastructure, exterior fencing, and HVAC modifications. The NAICS code is 236220. The solicitation will be available on July 14, 2020 on SAM.gov and a pre-proposal conference is scheduled for July 22, 2020. Proposals are due on August 25, 2020 and award is anticipated in January 2021. The contract will be a firm-fixed price awarded by the General Services Administration Public Buildings Service Region 5.

View the file

Other files for this federal contract opportunity

Other files attached to Construction Contract for the Customs and Border Protection Seized Cargo Facility, newest first.
File Type Posted
47PF0020R0040 - Amendment 08.pdf PDF
47PF0020R0040 - Amendment 07.pdf PDF
CBP Vault Solicitation RFIs 09-01-2020.pdf PDF
47PF0020R0040 - Amendment 06.pdf PDF
47PF0020R0040 - Amendment 05.pdf PDF
018111 Sustainable Design Requirements FY15 Update Oct. 1 2014.pdf PDF
CBP Vault Solicitation RFIs 8.25.2020.pdf PDF
47PF0020R0040 - Amendment 04.pdf PDF
GC Reps and Certs Aug 2020 r1 8-19-2020.pdf PDF
CBP Vault Amendment 04 - Language.pdf PDF
CBP Site Visit Attendance.pdf PDF
CBP Vault Solicitation RFIs 8.19.2020.pdf PDF
47PF0020R0040 - Amendment 03.pdf PDF
CBP Vault Solicitation RFIs - Amendment 03.pdf PDF
CBP Pre-proposal Agenda - Final.pdf PDF
David Bacon Wage Rates MI20190101 7.24.2020.pdf PDF
Pre. Prop. Attendance Sheet.pdf PDF
KSP Construction Product Tracking Form.pdf PDF
47PF0020R0040 - Amendment 02 PDF.pdf PDF
CBP 47PF0020R0040 RFI List from PreProposal Conf.pdf PDF
BrokerSCV-Walk-thru-20200722-FINAL.pdf PDF
CIO_P_21001I__CHGE_1_GSA_Information_Technology_IT_Security_Policy__Signed_on_10-20-2015.pdf PDF
47PF0020R0040 - Amendment 01.pdf PDF
CBP Vault Supplemental Pricing Form - SF1442 Attachment R1.pdf PDF
Site Visit Request Form - CBP Cargo Facility.pdf PDF
GC Reps and Certs 07-14-2020.pdf PDF
Past Performance Reference Questionnaire.pdf PDF
SBSA GC Solicitation 07-14-20.pdf PDF
CBP Cargo Facility Pre-Proposal RSVP Form.pdf PDF
SF24-16d.pdf PDF
CBP Vault Supplemental Pricing Form - SF1442 Attachment.pdf PDF
SBSA GC Agreement 07-14-20.pdf PDF
SF1442-14b - CBP Vault.pdf PDF
GSA527-15e (1).pdf PDF
Show all 34

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

CBP Seized Cargo Vault GSA PBS Region 5 Broker Building - Detroit, MI PCN # N1813678 Amendment Release

HIGH-PERFORMANCE COATINGS 099600 - 1

PROPERTY OF THE UNITED STATES GOVERNMENT

FOR OFFICIAL USE ONLY

Do not remove this notice Properly destroy documents when no longer needed

SECTION 099600 - HIGH-PERFORMANCE COATINGS

PART 1 - GENERAL

1.1 RELATED DOCUMENTS

A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply to this Section.

1.2 SUMMARY

A. Section includes surface preparation and the application of high-performance coating systems on the following substrates:

1. Interior Substrates:

a. Concrete, vertical surfaces.

b. Gypsum board.

B. Related Requirements:

1. Section 099123 "Interior Painting" for general field painting.

1.3 DEFINITIONS

A. MPI Gloss Level 5: 35 to 70 units at 60 degrees, according to ASTM D523.

B. MPI Gloss Level 6: 70 to 85 units at 60 degrees, according to ASTM D523.

C. MPI Gloss Level 7: More than 85 units at 60 degrees, according to ASTM D523.

1.4 ACTION SUBMITTALS

A. Product Data: For each type of product. Include preparation requirements and application instructions.

1. Include printout of current "MPI Approved Products List" for each product category specified, with the proposed product highlighted.

2. Indicate VOC content.

HIGH-PERFORMANCE COATINGS 099600 - 2

FOR OFFICIAL USE ONLY

Do not remove this notice Properly destroy documents when no longer needed

B. Samples for Verification: For each type of coating system and each color and gloss of topcoat indicated.

1. Submit Samples on rigid backing, 8 inches square.

2. Apply coats on Samples in steps to show each coat required for system.

3. Label each coat of each Sample.

4. Label each Sample for location and application area.

C. Product List: Cross-reference to coating system and locations of application areas. Use same designations indicated on Drawings and in schedules. Include color designations.

1.5 MAINTENANCE MATERIAL SUBMITTALS

A. Furnish extra materials, from the same product run, that match products installed and that are packaged with protective covering for storage and identified with labels describing contents.

1. Coatings: 5 percent, but not less than 1 gal. of each material and color applied.

1.6 QUALITY ASSURANCE

A. Mockups: Apply mockups of each coating system indicated to verify preliminary selections made under Sample submittals and to demonstrate aesthetic effects and set quality standards for materials and execution.

1. Architect will select one surface to represent surfaces and conditions for application of each coating system.

a. Wall and Ceiling Surfaces: Provide samples of at least 100 sq. ft.

b. Other Items: Architect will designate items or areas required.

2. Final approval of color selections will be based on mockups.

a. If preliminary color selections are not approved, apply additional mockups of additional colors selected by Architect at no added cost to Owner.

3. Approval of mockups does not constitute approval of deviations from the Contract Documents contained in mockups unless Architect specifically approves such deviations in writing.

4. Subject to compliance with requirements, approved mockups may become part of the completed Work if undisturbed at time of Substantial Completion.

HIGH-PERFORMANCE COATINGS 099600 - 3

FOR OFFICIAL USE ONLY

Do not remove this notice Properly destroy documents when no longer needed

1.7 DELIVERY, STORAGE, AND HANDLING

A. Store materials not in use in tightly covered containers in well-ventilated areas with ambient temperatures continuously maintained at not less than 45 deg F.

1. Maintain containers in clean condition, free of foreign materials and residue.

2. Remove rags and waste from storage areas daily.

1.8 FIELD CONDITIONS

A. Apply coatings only when temperature of surfaces to be coated and ambient air temperatures are between 50 and 95 deg F.

B. Do not apply coatings when relative humidity exceeds 85 percent; at temperatures less than 5 deg F above the dew point; or to damp or wet surfaces.

C. Do not apply exterior coatings in snow, rain, fog, or mist.

PART 2 - PRODUCTS

2.1 MANUFACTURERS

A. Manufacturers: Subject to compliance with requirements, available manufacturers offering products that may be incorporated into the Work include, but are not limited to the following:

1. Benjamin Moore & Co.

2. PPG Paints.

3. Sherwin-Williams Company (The).

B. Products: Subject to compliance with requirements, available products that may be incorporated into the Work include, but are not limited to products listed in the Interior High-Performance Coating Schedule for the coating category indicated.

2.2 HIGH-PERFORMANCE COATINGS, GENERAL

A. MPI Standards: Products shall comply with MPI standards indicated and shall be listed in its "MPI Approved Products Lists."

B. Material Compatibility:

HIGH-PERFORMANCE COATINGS 099600 - 4

FOR OFFICIAL USE ONLY

Do not remove this notice Properly destroy documents when no longer needed

1. Materials for use within each paint system shall be compatible with one another and substrates indicated, under conditions of service and application as demonstrated by manufacturer, based on testing and field experience.

2. For each coat in a paint system, products shall be recommended in writing by topcoat manufacturers for use in paint system and on substrate indicated.

3. Products shall be of same manufacturer for each coat in a coating system.

C. VOC Content: Products shall comply with VOC limits of authorities having jurisdiction and, for interior paints and coatings applied at Project site, the following VOC limits, exclusive of colorants added to a tint base, when calculated according Par SCAQMD 2004 (EPA Method 24):

1. All VOC containing materials, regardless of products specified, shall comply with

SCAQMD Rule 1113 for l< 50 grams per liter (g/L) post-tint..

D. Colors: As selected by Architect from manufacturer's full range unless where indicated in color schedule.

PART 3 - EXECUTION

3.1 EXAMINATION

A. Examine substrates and conditions, with Applicator present, for compliance with requirements for maximum moisture content and other conditions affecting performance of the Work.

B. Maximum Moisture Content of Substrates: When measured with an electronic moisture meter as follows:

1. Concrete: 12 percent.

2. Fiber-Cement Board: 12 percent.

3. Masonry (Clay and CMUs): 12 percent.

4. Gypsum Board: 12 percent.

C. Gypsum Board Substrates: Verify that finishing compound is sanded smooth.

D. Verify suitability of substrates, including surface conditions and compatibility, with existing finishes and primers.

E. Proceed with coating application only after unsatisfactory conditions have been corrected.

1. Application of coating indicates acceptance of surfaces and conditions.

HIGH-PERFORMANCE COATINGS 099600 - 5

FOR OFFICIAL USE ONLY

Do not remove this notice Properly destroy documents when no longer needed

3.2 PREPARATION

A. Comply with manufacturer's written instructions and recommendations in "MPI Architectural Painting Specification Manual" applicable to substrates and coating systems indicated.

B. Remove hardware, covers, plates, and similar items already in place that are removable and are not to be painted. If removal is impractical or impossible because of size or weight of item, provide surface-applied protection before surface preparation and painting.

1. After completing painting operations, use workers skilled in the trades involved to reinstall items that were removed. Remove surface-applied protection if any.

C. Clean substrates of substances that could impair bond of coatings, including dust, dirt, oil, grease, and incompatible paints and encapsulants.

1. Remove incompatible primers and reprime substrate with compatible primers or apply tie coat as required to produce coating systems indicated.

D. Concrete Substrates: Remove release agents, curing compounds, efflorescence, and chalk. Do not coat surfaces if moisture content or alkalinity of surfaces to be coated exceeds that permitted in manufacturer's written instructions.

1. Clean surfaces with pressurized water.

E. Masonry Substrates: Remove efflorescence and chalk. Do not coat surfaces if moisture content, alkalinity of surfaces, or alkalinity of mortar joints exceeds that permitted in manufacturer's written instructions.

1. Clean surfaces with pressurized water.

F. Steel Substrates: Remove rust, loose mill scale, and shop primer if any. Clean using methods recommended in writing by paint manufacturer.

G. Shop-Primed Steel Substrates: Clean field welds, bolted connections, and areas where shop paint is abraded. Paint exposed areas with the same material as used for shop priming to comply with SSPC-PA 1 for touching up shop-primed surfaces.

3.3 APPLICATION

A. Apply high-performance coatings according to manufacturer's written instructions and recommendations in "MPI Architectural Painting Specification Manual."

1. Use applicators and techniques suited for coating and substrate indicated.

HIGH-PERFORMANCE COATINGS 099600 - 6

FOR OFFICIAL USE ONLY

Do not remove this notice Properly destroy documents when no longer needed

2. Coat surfaces behind movable equipment and furniture same as similar exposed surfaces. Before final installation, coat surfaces behind permanently fixed equipment or furniture with prime coat only.

3. Coat backsides of access panels, removable or hinged covers, and similar hinged items to match exposed surfaces.

4. Do not apply coatings over labels of independent testing agencies or equipment name, identification, performance rating, or nomenclature plates.

B. Tint each undercoat a lighter shade to facilitate identification of each coat if multiple coats of the same material are to be applied. Tint undercoats to match color of finish coat, but provide sufficient difference in shade of undercoats to distinguish each separate coat.

C. If undercoats or other conditions show through final coat, apply additional coats until cured film has a uniform coating finish, color, and appearance.

D. Apply coatings to produce surface films without cloudiness, spotting, holidays, laps, brush marks, runs, sags, ropiness, or other surface imperfections. Produce sharp glass lines and color breaks.

3.4 CLEANING AND PROTECTION

A. At end of each workday, remove rubbish, empty cans, rags, and other discarded materials from Project site.

B. After completing coating application, clean spattered surfaces. Remove spattered coatings by washing, scraping, or other methods. Do not scratch or damage adjacent finished surfaces.

C. Protect work of other trades against damage from coating operation. Correct damage to work of other trades by cleaning, repairing, replacing, and recoating, as approved by Architect, and leave in an undamaged condition.

D. At completion of construction activities of other trades, touch up and restore damaged or defaced coated surfaces.

3.5 INTERIOR HIGH-PERFORMANCE COATING SCHEDULE

A. Concrete Substrates, Vertical Surfaces:

1. Epoxy-Modified Latex System MPI INT 3.1G:

a. Prime Coat: Epoxy-modified latex, matching topcoat.

b. Intermediate Coat: Epoxy-modified latex, matching topcoat.

c. Topcoat: Epoxy-modified latex, semi-gloss (MPI Gloss Level 5), MPI #215.

HIGH-PERFORMANCE COATINGS 099600 - 7

FOR OFFICIAL USE ONLY

Do not remove this notice Properly destroy documents when no longer needed

B. Cement Board Substrates:

1. Epoxy-Modified Latex System MPI INT 3.3D:

a. Prime Coat: Epoxy-modified latex, matching topcoat.

b. Intermediate Coat: Epoxy-modified latex, matching topcoat.

c. Topcoat: Epoxy-modified latex, semi-gloss (MPI Gloss Level 5), MPI #215.

C. Steel Substrates:

1. Epoxy-Modified Latex System MPI INT 5.1K:

a. Prime Coat: Primer, rust inhibitive, water based, MPI #107.

b. Intermediate Coat: Epoxy-modified latex, interior, matching topcoat.

c. Topcoat: Epoxy-modified latex, semi-gloss (MPI Gloss Level 5), MPI #215.

D. Gypsum Board Substrates:

1. Epoxy-Modified Latex System MPI INT 9.2F:

a. Prime Coat: Primer sealer, latex, interior, MPI #50.

b. Intermediate Coat: Epoxy-modified latex, matching topcoat.

c. Topcoat: Epoxy-modified latex, semi-gloss (MPI Gloss Level 5), MPI #215.

END OF SECTION 099600