4-Arch Bid Drawing 657-20-101JB (14 Pages) 5 28 2021 .pdf

PDF 5 MB Posted

Attached to
Z2DA--657-20-101JB FCA-Renovate Space for Whole Health Clinic
Solicitation number
36C25522R0058
Issued by

About this file

This document package includes architectural drawings and specifications for the renovation of space for a whole health clinic at the Jefferson Barracks VA Medical Center in St. Louis, Missouri. The project involves renovating space on the second floor, including demolition of existing walls, doors, ceilings and fixtures; construction of new walls, doors, ceilings and fixtures; and installation of new flooring. Key areas of renovation include a reception area, exam rooms, offices, classrooms, waiting rooms, and corridors. Mechanical, electrical and plumbing systems will be updated as indicated on supporting engineering drawings. The project is funded under Solicitation 36C25522R0058 and will be performed according to the terms and conditions therein.

The architectural drawings provide details of the existing conditions and scope of demolition and construction work. Sheets include plans depicting wall layouts, door and fixture schedules, sections and elevations detailing wall, door and ceiling assemblies, and construction details. Specifications are also included outlining materials, finishes and technical requirements. The package provides all necessary information for contractors to prepare bids to complete the renovation for the Whole Health Clinic space at the Jefferson Barracks VA Medical Center in St. Louis, Missouri.

View the file

Other files

Show all 21

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

AFF ABOVE FINISHED FLOOR

ACP/APC ACOUSTIC CEILING PANEL/

ACOUSTIC PANEL CEILING

ACT ACOUSTIC(AL) TILE

ADJ ADJUSTABLE

ADT'L ADDITIONAL

AGG AGGREGATE

ALT ALTERNATE

AL ALUMINUM

APPROX APPROXIMATE(LY)

ASPH ASPHALT

AUTO AUTOMATIC

B/O BOTTOM OF

BD BOARD

BLDG BUILDING

BLKG BLOCKING

BOT BOTTOM

BRG BEARING

CENTERLINE

C/C CENTER TO CENTER

CJ CONTROL JOINT

CLL CONTRACT LIMIT LINE

CEM CEMENT(ITIOUS)

CMU CONCRETE MASONRY UNIT

CLG CEILING

CLR CLEAR

COL COLUMN

CONC CONCRETE

CONST CONSTRUCTION

CONT CONTINUOUS

CPT CARPET

CT CERAMIC TILE

CTR CENTER(ED)

DF DRINKING FOUNTAIN

DS DOWNSPOUT

DBL DOUBLE

DEG DEGREE

DEMO DEMOLITION

DET/DTL DETAIL

DIA DIAMETER

DIM DIMENSION

DN DOWN

DWG(S) DRAWING(S)

E EAST

EC ELECTRICAL CONTRACTOR

EHO ELECTRICAL HOLD OPEN

EJ EXPANSION JOINT

EW EACH WAY

EA EACH

EIFS EXTERIOR INSULATION

FINISH SYSTEM

EL ELEVATION

ELEC ELECTRIC(AL)

ELEV ELEVATOR

EMER EMERGENCY

EQ EQUAL

EQUIP EQUIPMENT

EXIST EXISTING

EXT EXTERIOR

EWC ELECTRIC WATER COOLER

FD FLOOR DRAIN

FE FIRE EXTINGUISHER

FFE FINISH FLOOR ELEVATION

FV FIELD VERIFY

FEC FIRE EXTINGUISHER CABINET

FDN FOUNDATION

FIN FINISH

FLSHG FLASHING

FLR FLOOR

FRMG FRAMING

FT FOOT/FEET

FTG FOOTING

GC GENERAL CONTRACTOR

GA GAUGE

GALV GALVANIZED

GEN GENERAL

GYP GYPSUM

HM HOLLOW METAL

HDWR HARDWARE

HOL HOLLOW

HOR HORIZONTAL

HT HEIGHT

HVAC HEATING/VENTILATION/AIR

CONDITIONING

IDPH ILLINOIS DEPARTMENT OF

PUBLIC HEALTH

ID INSIDE DIAMETER

IN INCH

INCL INCLUDING

INSUL INSULATION

INT INTERIOR

JAN JANITOR

JT JOINT

LAV LAVATORY

LB(S) POUND(S)

L/S LANDSCAPE

LT LIGHT

MO MASONRY OPENING

MAS MASONRY

MAT'L MATERIAL

MAX MAXIMUM

MECH MECHANICAL

MFR MANUFACTURER

MIN MINIMUM

MISC MISCELLANEOUS

MTD MOUNTED

MTL METAL

N NORTH

NIC NOT IN CONTRACT

NTS NOT TO SCALE

NOM NOMINAL

OC ON CENTER

OD OUTSIDE DIAMETER

O TO O OUT TO OUT

OPNG OPENING

OPP OPPOSITE

OVHD OVERHEAD

PEB PRE-ENGINEERED BUILDING

PJF PREFORMED JOINT FILLER

PT PRESSURE TREATED

PERIM PERIMETER

PL PLATE

PLAM PLASTIC LAMINATE

PLBG PLUMBING

PLYWD PLYWOOD

PNT PAINT

PR PAIR

PTD PAINTED

PWR POWER

RB RUBBER BASE

RD ROOF DRAIN

RO ROUGH OPENING

RAD RADIUS

REC RECESSED

REINF REINFORCED

REQ'D REQUIRED

REV REVISED (REVISION)

RM ROOM

S SOUTH

SB SPLASH BLOCK

SF SQUARE FEET

SS STAINLESS STEEL

SIM SIMILAR

SPEC SPECIFICATIONS

SQ SQUARE

STD STANDARD

STL STEEL

STOR STORAGE

STRUCT STRUCTURAL

SUSP SUSPENDED

T&G TONGUE AND GROOVE

T/O TOP OF

TELE TELEPHONE

TRTD TREATED

TS TUBE STEEL

TYP TYPICAL

UNFIN UNFINISHED

UNO UNLESS NOTED OTHERWISE

VCT VINYL COMPOSITION TILE

VIF VERIFY IN FIELD

VERT VERTICAL

W WEST

W/ WITH

W/O WITHOUT

WC WATER CLOSET

WWF WELDED WIRE FABRIC

WD WOOD

WH WATER HEATER

WT WEIGHT

CL

DEMOLITION KEYNOTE

WINDOW TYPE

ROOF PITCH SYMBOL

DOOR NUMBER

TYPICAL KEYNOTE CEILING/ SOFFIT

HEIGHT

MATL

1'-0"

-1

GENERAL NOTES

1. INDICATIONS OF PROJECT LIMITS OR LINES OF DEMARCATION ARE SHOWN FOR GENERAL SCOPE DEFINITION AND REFLECT THE UNDERSTANDING OF THE DESIGNER AS TO THE LIMITATIONS OF THE WORK AREA IN AN OCCUPIED AREA. ACTUAL CONTRACT LIMITS ARE TO BE DETERMINED BY AGREEMENT BETWEEN THE COR AND

CONTRACTOR BEFORE THE START OF THE WORK.

2. DRAWINGS ARE PREPARED USING DIMENSIONS AND PRODUCT DRAWINGS ARE PREPARED USING DIMENSIONS AND PRODUCT AND DETAILS FOR SPECIFIC PRODUCTS MAY CHANGE BEFORE THEY ARE AND DETAILS FOR SPECIFIC PRODUCTS MAY CHANGE BEFORE THEY ARE ACTUALLY INCORPORATED INTO THE WORK, AND PRODUCTS BY OTHER MANUFACTURERS ARE ALSO ACCEPTABLE. THEREFORE, ACTUAL INSTALLATION DETAILS AND DIMENSIONS MAY DIFFER FROM THOSE SHOWN. CONTRACTOR SHALL VERIFY INSTALLATION REQUIREMENTS FOR ALL PRODUCTS TO BE INCORPORATED IN THE WORK (INCLUDING THICKNESS FOR RECESSED OR SEMI-RECESSED PRODUCTS) AND IS RESPONSIBLE FOR ACCOMMODATING AND COORDINATING CHANGES TO OTHER MATERIALS OR PRODUCTS THAT ARE NECESSARY BECAUSE OF THESE DIFFERENCES.

3. THE DRAWINGS AND SPECIFICATIONS ARE SEPARATED INTO DISCIPLINES FOR CONVENIENCE. THE SEPARATIONS USED ARE USED ONLY FOR THE PURPOSES OF CONVENIENCE AND REFERENCE AND IN NO WAY DO THEY DEFINE OR LIMIT THE SCOPE OR INTENT OF ANY PART OF THE DRAWINGS, OR OF THE DRAWINGS AND SPECIFICATIONS AS A WHOLE. THE FACT THAT THE DRAWINGS ARE SEPARATED IN NO WAY SUGGESTS THAT THE WORK IS NOT TO BE CONSTRUCTED AS A COMPLETE, INTEGRATED AND UNIFIED WHOLE.

4. THE DRAWINGS AND SPECIFICATIONS, INCLUDING DRAWINGS PREPARED BY SPECIFIC ENGINEERING DISCIPLINES ARE COMPLEMENTARY; ITEMS SHOWN IN ANY ONE LOCATION IN THE DRAWINGS SHALL BE CONSIDERED TO BE REQUIREMENTS OF THE CONTRACT FOR CONSTRUCTION. IN THE EVENT OF AN INCONSISTENCY BETWEEN THE DRAWINGS AND SPECIFICATIONS, OR WITHIN EITHER DOCUMENT, THE CONTRACTOR SHALL SEEK CLARIFICATION OR INTERPRETATION FROM THE COR PRIOR TO BIDDING. WHERE INCONSISTENCIES ARE NOT CLARIFIED PRIOR TO BIDDING, AND WHERE THE ACTUAL SOLUTION OR INTENT CANNOT BE REASONABLY INFERRED, THE CONTRACTOR SHALL PROVIDE THE BETTER QUALITY OR GREATER

QUANTITY OF WORK.

5. USE OF THE WORD "VERIFY" POINTS OUT A SITUATION WHICH MUST BE CONFIRMED PRIOR TO PROCEEDING WITH THE WORK, FABRICATION OF EQUIPMENT, OR ORDERING MATERIAL. NOTIFY THE COR OF ANY

DISCREPANCY DISCOVERED.

6. THE CONTRACTOR IS RESPONSIBLE FOR CHECKING ALL FIELD CONDITIONS AND DIMENSIONS AS THEY RELATE TO THIS PROJECT. SHOULD DISCREPANCIES EXIST BETWEEN THE WORK INDICATED AND ACTUAL FIELD

CONDITIONS NOTIFY THE COR PRIOR TO PROCEEDING WITH THE WORK.

7. DO NOT SCALE THE DRAWINGS. DRAWING SCALES AS INDICATED ARE FOR REFERENCE ONLY AND ARE NOT INTENDED TO ACCURATELY DEPICT ACTUAL OR DESIGNATED CONDITIONS. WRITTEN DIMENSIONS SHALL

GOVERN.

8. COORDINATE WORK OF ALL TRADES PRIOR TO STARTING CONSTRUCTION.

9. THE CONTRACTOR AND SUBCONTRACTORS INVOLVED IN THIS PROJECT SHALL BE RESPONSIBLE FOR DESIGNING AND INSTALLING THEIR RESPECTIVE WORK AND SYSTEMS TO MEET ALL APPLICABLE FEDERAL, STATE, AND LOCAL CODES, LAWS, SAFETY REGULATIONS, HAZARDOUS WASTE LAWS, ETC. THE CONTRACTOR

SHALL FURNISH ALL NECESSARY LICENSES AND/OR PERMITS.

10. THE CONTRACTOR SHALL REVIEW THE DRAWINGS AND UNDERSTAND THE SCOPE OF THE DRAWINGS TO BE THE FOLLOWING: THESE CONSTRUCTION DOCUMENTS (DRAWINGS, SPECIFICATIONS, ADDENDA, ETC.)

INDICATE THE GENERAL SCOPE OF THE PROJECT IN TERMS OF ARCHITECTURAL DESIGN CONCEPTS, THE DIMENSIONS OF THE BUILDING, THE MAJOR ARCHITECTURAL ELEMENTS, AND THE MAJOR STRUCTURAL, MECHANICAL, ELECTRICAL, AND DATA SYSTEMS. THE DOCUMENTS DO NOT AND ARE NOT INTENDED TO INDICATE OR DESCRIBE IN DETAIL ALL THE NECESSARY WORK REQUIRED FOR FULL PERFORMANCE OF, AND COMPLETION OF THE REQUIREMENTS OF THE CONTRACT. ON THE BASIS OF THE GENERAL SCOPE INDICATED IN THESE DOCUMENTS, THE TRADE CONTRACTORS SHALL FURNISH ALL ITEMS REQUIRED FOR THE PROPER EXECUTION AND COMPLETION OF THEIR WORK. ALL WORK SHALL BE COMPLETE IN EVERY DETAIL AND THE CONTRACTORS SHALL PROVIDE A ONE YEAR WARRANTY FOR THEIR WORK UNLESS A LONGER WARRANTY IS

INDICATED IN THE SPECIFICATIONS.

11. CONTRACTORS SHALL FOLLOW AND OBEY ALL FEDERAL, STATE AND LOCAL CODES, LAWS, SAFETY

REGULATIONS AND HAZARDOUS WASTE LAWS, ETC.

DEMOLITION NOTES

1. KEY NOTES AND DRAWINGS ARE INTENDED TO GRAPHICALLY REPRESENT GENERAL WORK AND DO NOT

PORTRAY FULL SCOPE OF THE PROJECT. SEE SPECIFICATIONS FOR DETAILED REQUIREMENTS.

2. REMOVE EXISTING CONSTRUCTION AS DESIGNATED HEREIN AND CLEAR AREA OF DEBRIS PRIOR TO

PROCEEDING WITH NEW CONSTRUCTION.

3. EXISTING EQUIPMENT REMOVED SHALL BE PROPERLY DISPOSED OFF MEDICAL CENTER GROUNDS.

4. PATCH WALL OPENING SHALL MATCH THE INTEGRITY OF ADJACENT CONSTRUCTION UNLESS INDICATED

OTHERWISE.

5. NOTIFY COR OF ANY DEMOLITION REQUIRED AND NOT INDICATED FOR INSTALLATION OF ELECTRICAL OR DATA ITEMS. AFTER SUCH DEMOLITION AND INSTALLATION, PATCH OR REPLACE MATERIALS AND FINISHES TO MATCH

EXISTING.

6. THE INFORMATION CONTAINED IN THESE DEMOLITION DOCUMENTS DEFINES GENERAL SCOPE ONLY AND DOES NOT RELIEVE THE CONTRACTOR OF THE RESPONSIBILITY OF PROVIDING ALL DEMOLITION REQUIRED FOR THE

COMPLETION OF THE PROJECT.

7. REFER TO THE ELECTRICAL DRAWINGS FOR FURTHER INFORMATION REGARDING DEMOLITION OF ELECTRICAL

SYSTEMS.

8. BEFORE THE START OF WORK, IDENTIFY ANY REQUIRED DEMOLITION BEYOND THE IDENTIFIED PROJECT SCOPE WHETHER ABOVE, BELOW OR OUTSIDE PROJECT AREA. NOTIFY AND COORDINATE WITH THE COR, PROVIDE DEMOLITION OF THESE AREAS AND PATCH THE SAME AS A PART OF THE SCOPE OF THE PROJECT.

9. ALL DEMOLITION WORK SHALL BE PERFORMED WITH DUE CARE AND DILIGENCE IN ORDER TO PREVENT ARBITRARY DAMAGE OR INTERRUPTION OF SERVICE OR CONCEALED UTILITIES INTENDED TO REMAIN IN SERVICE. DISCOVERY OF UTILITIES OR CONDITIONS LOCATED DIFFERENTLY FROM THAT INDICATED OR THAT

ARE NOT IDENTIFIED SHALL BE REPORTED TO THE CONTRACTING OFFICER REPRESENTATIVE.

10. ALL HAZARDOUS MATERIAL ABATEMENT TO BE DONE AS INDICATED IN SPECIFICATIONS AND COORDINATED

WITH LICENSED ABATEMENT CONTRACTOR.

CORE TYPES

C. CAST IN PLACE CONCRETE

G. CONCRETE MASONRY UNIT (GROUTED

SOLID)

H. CONCRETE MASONRY UNIT (HOLLOW)

M. METAL STUD FRAMING / METAL FURRING

MM. METAL STUD FRAMING (2 ROWS,

PARALLEL WITH PRESCRIBED AIR GAP

BETWEEN

S. METAL SHAFT WALL CH STUD

T. TILT-UP CONCRETE PANEL

W. WOOD STUD FRAMING / FURRING

SUBSTRATE

CONFIGURATION

a. 5/8" GWB (1 LAYER)

b. 5/8" GWB (2 LAYER)

c. 5/8" GWB (3 LAYER)

d. 5/8" GWB (4 LAYER)

e. 1/2" GWB (1 LAYER)

f. 1/2" GWB (2 LAYER)

g. 1/2" PLWD (1 LAYER)

h. 1/2" PLWD, 1/2" GWB (1 LAYER)

j. 1/2" PLWD, 5/8" GWB (1 LAYER)

m. 5/8" CMT (1 LAYER)

n. 1/2" CMT (1 LAYER)

s. 1" SHAFT LINER

(NONE) CORE ONLY

INSULATION TYPES

A. ACOUSTIC INSULATION

T. THERMAL INSULATION

Xxx##

# X

INSULATION TYPE

CORE SIZE

SUBSTRATE

CORE TYPE

FIRE RATING

PARTITION TAG

TYPE MARK

HOLD SUBSTRATE 1/2" OFF

FINISH FLOOR TYPICAL, NO

EXCEPTIONS

ONE LAYER 5/8" GYPSUM

WALL BOARD EACH SIDE

ON METAL STUDS

TAG STUD SIZE OVERALL THICK UL ASSEMB STC*

Maa1

Maa2

Maa3

Maa4

Maa6

Maa8

REFER TO

PARTITION TAG

FOR

INSULATION

INFORMATION

(SHOWN HERE

FOR

REFERENCE

ONLY - MAY NOT

EXIST), AND

FIRE RATING

1-5/8"

2-1/2"

3-5/8"

4"

6"

8"

2-7/8"

3-3/4"

4-7/8"

5-1/4"

7-1/4"

9-1/4"

STRUCTURAL DECK ABOVE

SILL

PLAN

HEAD

HOLD SUBSTRATE 1/2" OFF

FINISH FLOOR TYPICAL, NO

EXCEPTIONS

ONE LAYER 5/8" GYPSUM

WALL BOARD ON METAL

STUDS

TAG STUD SIZE OVERALL THICK UL ASSEMB STC*

Ma0

Ma1

Ma2

Ma3

Ma4

Ma6

Ma8

REFER TO

PARTITION TAG

FOR

INSULATION

INFORMATION

(SHOWN HERE

FOR

REFERENCE

ONLY - MAY NOT

EXIST), AND

FIRE RATING

7/8"

1-5/8"

2-1/2"

3-5/8"

4"

6"

8"

1-1/2"

2-1/4"

3-1/8"

4-1/4"

4-5/8"

6-5/8"

8-5/8"

STRUCTURAL DECK ABOVE

SILL

PLAN

HEAD

FIRE SEALANT

FIRE RATED GYP WALL BD (5/8")

SHAFTWALL LINER PANEL (1")

UNDERSIDE OF STRUCTURE

*FIRESTOP ALL

PENETRATIONS

Sas2 (1-HR) RATING

Sbs2 (2-HR) RATING

SEALANT SYSTEM COMPLIANT

WITH UL# HW-D-0372

BASE AS SCHEDULED

TAG STUD SIZE OVERALL THICK UL ASSEMB STC*

Sas0

Sbs2

REFER TO

PARTITION TAG

FOR

INSULATION

INFORMATION

(SHOWN HERE

FOR

REFERENCE

ONLY - MAY NOT

EXIST), AND

FIRE RATING

2 1/2" UL-415 423-1/8"

2 1/2" UL-415 423-3/4"

Sas4 4" UL-415 424-5/8"

Sbs4 4" UL-415 425-1/4"

SILL

PLAN

HEAD

1151 Kildaire Farm Rd.

Suite 120 Raleigh, NC 27511 www.acg-pa.com (919)858-7420

108 Benton Lodge Road Suite B Summerville, SC 29485 www.cemsengineering.com (843)875-3637Project Mgr: Alex Kramer (APOGEE)

Joint Venture An Alliance for Success

Revisions: Date

Drawing Title

Approved: Project Director

Project Title

Location

VA PROJECT NUMBER

Building Number

Drawing Number

Dwg of

VA FORM 08-6231

Office of Construction and Facilities Management

CONSULTANTS: PROJECT MANAGER

Date Checked Drawn

FULLY SPRINKLERED

ACG Project Number

U.S. Department of Veterans Affairs# © COPYRIGHT Apogee - CEMS JV, LLC

JOHN A. JURGIEL & ASSOCIATES, INC.

123 N. Main Street (636)757-3060 St. Charles, MO. 63301 Jurgiel.com

JURGIEL

JOHN A. JURGIEL & ASSOCIATES, INC.

/2

/2

:1

:1

P

M

A-001

ARCHITECTURAL SYMBOLS, PARTITION

TYPES, ABBREVIATIONS AND NOTES

1 14RR

RENOVATE SPACE FOR

WHOLE HEALTH

1 JEFFERSON BARRACKS DR.,

ST LOUIS, MO 63125

MAY 28, 2021

BID DOCUMENTS

657-20-101JB19-335

TJS

ABBREVIATIONS

ARCHITECTURAL SYMBOL LEGENDPARTITION TYPE KEY

PARTITION TYPE - Maa PARTITION TYPE - Ma_ PARTITION TYPE - Sas_ AND Sbs_

DocuSign Envelope ID: 16222EA7-D798-4CC7-9C06-921DD28D6352

5/26/2021

TESTIN

G

TENT

SCREENING

STATION

SCREENING

STATION

V A

N V

A N

V A

N

BUILDING SCHEDULE

1 OUTPATIENT CLINICS - VOS - LOGISTICS

1G EMERGENCY GENERATOR FOR BUILDING 1

1CC CONNECTING CORRIDORS

2 CEOSH

3 DOMICILIARY

3T DOMICILIARY OFFICES (MODULAR BLDG)

18 ADMINISTRATION

23 PROSTHETICS

24 CANTEEN - LIBRARY - AUDITORIUM

25 NATIONAL CANTEEN SERVICE (OUTLEASED)

32 FLAGPOLE

35 STORAGE

44 CONCRETE PLATFORM

45 CONCRETE PLATFORM

51 INPATIENT PSYCHIATRIC

51T NEURO PSYCHIATRIC (MODULAR BLDG)

52 LONG TERM SCI

52G EMERGENCY GENERATOR FOR BUILDING 52

52SG TRANSFER SWITCH BUILDING

53 MEDICAL REHABILITION

53G EMERGENCY GENERATOR FOR BUILDING 53

53T MEDICAL REHAB (MODULAR BLDG)

54 REHAB BUILDING (UNDER CONSTRUCTION)

55 CLINIC BUILDING (UNDER ACTIVATION)

55G EMERGENCY GENERATOR FOR BUILDING 55

56 TENANT BUILDING

56G EMERGENCY GENERATOR FOR BUILDING 56

57 ENGINEERING - WAREHOUSE

58 MENTAL HEALTH CLINIC

59 FISHER HOUSE

60 MAIN KITCHEN

60G EMERGENCY GENERATOR FOR BUILDING 60

60T FOOD - NUTRITION - DIETETICS

61 RECREATION - AUDITORIUM

63 GYM - POOL

75 UTILITY PLANT - GENERATOR BLDG & SUBSTATION

81 BUS STOP

89 SECURITY STATION

93 HAZARDOUS WASTE STORAGE

101T MAJOR PROJECTS CFM (MODULAR BLDG)

102T MAJOR PROJECTS (MODULAR BLDG)

104T RECORDS (MODULAR BLDG)

JE

FFERSO

N D

RIV

E

JEFFERSON BARRACKS

NATIONAL CEMETERY

PHASE 1 TRANSFER

SO

U

TH

G

ATE E

N

TR

AN

C E D

R

IV

E

JEFFERSON BARRACKS

NATIONAL CEMETERY

PHASE 2 TRANSFER

FUTURE PROPERTY LINE

TO INTERSTATE 255

N O

R T H

G A T E E

N T R

A N

C E D

R

IV

E

KOCH ROAD

KOCH ROAD

GRAVEL

PARKING

AREA

MISSISSIPPI RIVER

JEFFERSON

BARRACKS

NATIONAL

CEMETERY

CONSTRUCTION ZONE

CONSTRUCTION ZONE

CONST. ZONE

CONST. ZONE

"255 LOT"

CONST.

ZONE

CONST.

ZONE

CONST.

ZONE

60T 55 51T

1G

1CC

104T

101T

1CC

1CC

1CC

3T

55G

52G

53G

60G

52SG

1CC

56G

1CC

53T

102T

D UST CO LLEC TO R

4 160 VO LTS

L

IQ

UE

FIED

PETR

O

LEUM

G

AS

F

LAM

M

A

BLE G

AS 2

T RAS H CO M PAC TO R

P S

IL

VER

B

UILD

ING

1 23

B UIL DING 23

V A PO LICE

E LE CT RIC A CCE SS

T RAN SFO R M ER

T RAN SFO R M ER

T RAN SFO R M ER

E LE CTR IC PAN EL

H VA C U NIT

H VA C U NIT

S &C PA D M O U NTED G EAR

C ATAL O G # 55152 -C3DG IG 2P1 V M O D EL# P M H-9E E13 299 SG -52

1 3278

T RAN SFO R M ER

4 5

LOGISTICS PLAN LEGEND

BUILDING IN CONTRACT

EXISTING BUILDINGS

CONTRACTOR STORAGE CONTAINER

CONTRACTOR VICINITY PARKING

DUMPSTER

PORTA-JONS

DIRECTION FOR SITE ACCESS

BUILDING ACCESS

SITE ACCSESS ROUTE

1151 Kildaire Farm Rd.

Suite 120 Raleigh, NC 27511 www.acg-pa.com (919)858-7420

108 Benton Lodge Road Suite B Summerville, SC 29485 www.cemsengineering.com (843)875-3637Project Mgr: Alex Kramer (APOGEE)

Joint Venture An Alliance for Success

# KEY NOTES:

Revisions: Date

Drawing Title

Approved: Project Director

Project Title

Location

VA PROJECT NUMBER

Building Number

Drawing Number

Dwg of

VA FORM 08-6231

Office of Construction and Facilities Management

CONSULTANTS: PROJECT MANAGER

SHEET NOTES:

Date Checked Drawn

FULLY SPRINKLERED

ACG Project Number

U.S. Department of Veterans Affairs# © COPYRIGHT Apogee - CEMS JV, LLC

JOHN A. JURGIEL & ASSOCIATES, INC.

123 N. Main Street (636)757-3060 St. Charles, MO. 63301 Jurgiel.com

JURGIEL

JOHN A. JURGIEL & ASSOCIATES, INC.

/2

/2

:1

:1

P

M

A-002

LOGISTICS SITE PLAN

2 14RER

RENOVATE SPACE FOR

WHOLE HEALTH

1 JEFFERSON BARRACKS DR.,

ST LOUIS, MO 63125

MAY 28, 2021

BID DOCUMENTS

657-20-101JB19-335

TJS

PROJECT DUMPSTER TO BE LOCATED NEAR PARKING

LOT BEHIND BUILDING. COORDINATE FINAL LOCATION

WITH COR.

CONTRACTOR PARKING ON SITE ADJACENT TO

BUILDING IS LIMITED. COORDINATE ADDITIONAL

PARKING IN REMOTE LOTS WITH COR.

NO CONEX STORAGE UNITS ADJACENT TO BUILDING.

COORDINATE LOCATION IN REMOTE PARKING LOT

WITH COR.

PORTABLE TOILET UNITS LOCATED NEAR PARKING

LOT BEHIND BUILDING.

CONTRACTOR USE OF ELEVATOR AND INTERIOR

ACCESS PATH LOCATED ON SHEET LS101.

CONTRACTOR TO KEEP NOISE AND DISTURBANCE TO

A MINIMUM INSIDE OF FACILITY.

GENERAL CONTRACTOR AND ALL SUBCONTRACTORS

REQUIRED TO UNDERGO COVID SCREENING

PROCEDURES PRIOR TO ENTERING THE SITE.

DEPENDING ON RESTRICTIONS IN PLACE, BUILDING

ENTRY MAY FLUXUATE. COORDINATE WITH COR

WEEKLY FOR UPDATES.

1 CONTRACTOR SITE ACCESS AND

VEHICULAR PATH

2 LOCATION OF CONTRACTOR VACINITY

PARKING

3 LOCATION OF DUMPSTER

4 LOCATION OF PORTA-JONS

5 LOCATION OF CONTRACTOR BUILDING

ACCESS

6 CONTRACTOR CONEX STORAGE

CONTAINER

7 BUILDING TO BE RENOVATED, BUILDING 1,

2ND FLOOR

8 LOCATION OF CONTRACTOR BULK

MATERIAL ACCESS, OFF PEAK HOURS

ONLY

N

AREA OF WORK

KEY PLAN

SCALE: NO SCALE

NORTH

0 8 16 32

Scale: 1" = 100'-0"

LOGISTICS SITE PLAN

A

A.3 B C C.1 D.1

D.2

E F G H J K M N O P Q

R

R

R.2 S T U V V.3

V.3U.1T.2T.1R.3

LL

C.2B.2B.1A.4

10.1

/1 AD102

/2 AD102/2 AD102

/1 AD102

10'-8" 10'-10 1/2"

3'-1 1/2"

11'-6 1/2" 10'-9"

3'-1 1/2"

10'-10 1/2" 10'-8 1/2"

8'-3 1/2" 7'-0" 7'-0" 7'-0" 8'-3 1/2"8'-3 1/2" 7'-0" 7'-0" 7'-0" 8'-3 1/2"

/4

/4

/4

/2

/4

/2

/4

/2

/4

/2

/4

4'-9 1/2" 13'-8 1/2" 18'-6" 18'-6" 19'-1 1/2" 18'-6" 19'-1 1/2" 18'-6" 18'-6" 13'-8 1/2" 4'-9 1/2"

EXAM

2E25A

EXAM

2E25

OFFICE

2E23

WAITING

ROOM

2E26

OFFICE

2E27

OFFICE

2E22

TOILET

2E22A

TOILET

2E28

EXAM

2E29

TOILET

2E25B TOILET

2E24

EXAM

2E21

OFFICE

2E20

CHASE

CH-E-1

OFFICE

2CO5

STORAGE

2CO6

ELEVATOR

NO. 2

E2

OFFICE

2CO8

OFFICE

2CO9

CONFERENCE

ROOM

2CO7

OFFICE

2CO3

THERAPY

2CO2

OFFICE

2CO4

CORRIDOR

H210

STAIR

S201

HAC

2E01

ROOF BELOW

ROOF BELOW

1'-0 1/2" 1'-1"

EXAM

2C11

PHONE CLO.

2C11A

OPTICAL

SHOP

2C12

NURSE

STATION

2C13

EXAM

2C14

EXAM

2C15

MEN'S

TOILET

2C16

KITCHEN

2C17

MECH.

2C18

LAB

2C19

WAITING

ROOM

2C20

OFFICE

2C22

ALCOVE

2C21

TOILET

2C24

OFFICE

2C23

EXAM

2C25

TOILET

2C27

HSKP

2C28

STAIR

S202

OFFICE

2C29

WAITING

ALCOVE

H205A

WAITING

2C01

RECEPTION

2C01A

EXAM

2C01B

CORR.

H205A

CORR.

H205A

CORR.

H206

STAIR

S203

HSKP

2W36 TOILET

2W34

OFFICE

2W35

OFFICE

2W33

EXAM

2W32

EXAM

2W30

VEST.

2W29E

TOILET

2W29F

EXAM

2W29D

STOR.

2W29C

OFFICE

2W29B

STOR.

2W29A

OFFICE

2W29

EXAM

2W28C

EXAM

2W28B

EXAM

2W28A

EXAM

2W28

EXAM

2W27

OFFICE

2W26

MECH.

2W25

EXAM

2W24

UNISEX

TOILET

2W23

EXAM

2W22C

PHARM.

OFF.

2W22A

OXYGEN

STO.

2W22B

MED. RM.

2W22

CORR.

H208

OFFICE

2W21

UNISEX

TOILET

2W20

WAITING

2W19

OFFICE

2W18

TLT.

2W14

EXAM

2W16

EXAM

2W15

TOILET

2W14

OFFICE

2W13

OFFICE

2W12

TOILET

2W11

EXAM

2W10

EXAM

2W09

TLT.

2W08

EXAM

2W07

BREAKROOM

2W06

STORAGE

2W05

MED

PREP

2W04

TOILET

2W03

FAX

2W02

RECEPTION

2W01

CORR.

H209

IRM

2C10A

4'-0 1/2"

4" 3'-10"

7'-8"

15'-10"15'-10"

OIT

2C10

10'-8"

A. SEE SHEET A-001 FOR GENERAL NOTES.

B. DEMOLITION THAT REQUIRES SYSTEM SHUT

DOWNS FOR PART OF, OR ALL OF THE

FLOOR OR BUILDING IS TO BE COORDINATED

WITH THE COR AND TAKE PLACE AFTER

NORMAL BUSINESS HOURS IF DIRECTED BY

THE COR. SEE ENGINEERING DRAWINGS

FOR LOCATIONS AND SCOPE.

C. DEMOLITION THAT GENERATES SIGNIFICANT

NOISE OR VIBRATION (CUTTING, DRILLING,

CORING, ETC.) TO BE COORDINATED WITH

COR PRIOR TO START OF DEMOLITION. SEE

ENGINEERING DRAWINGS FOR LOCATIONS

AND SCOPE.

D. WHERE REMOVING CMU, CONCRETE, OR

CLAY TILE WALLS, ALL VOIDS AND HOLES

CREATED IN FLOOR SLAB TO BE FILLED IN

WITH SELF-LEVELING COMPOUND FLUSH

WITH EXISTING FLOOR SLAB LEVEL (TYP.).

E. WALL REMOVED THIS FLOOR ARE CLAY TILE

OR CLAY TILE WITH FURRING.

SCOPE OF CONSTRUCTION

EXISTING WALL

DEMOLITION WALL

1151 Kildaire Farm Rd.

Suite 120 Raleigh, NC 27511 www.acg-pa.com (919)858-7420

108 Benton Lodge Road Suite B Summerville, SC 29485 www.cemsengineering.com (843)875-3637Project Mgr: Alex Kramer (APOGEE)

Joint Venture An Alliance for Success

Revisions: Date

Drawing Title

Approved: Project Director

Project Title

Location

VA PROJECT NUMBER

Building Number

Drawing Number

Dwg of

VA FORM 08-6231

Office of Construction and Facilities Management

CONSULTANTS: PROJECT MANAGER

SHEET NOTES:

WALL RATING LEGEND

1 HR - FIRE SEPARATION

2 HR - FIRE SEPARATION

SMOKE RATED

Date Checked Drawn

FULLY SPRINKLERED

ACG Project Number

U.S. Department of Veterans Affairs#

S S S S

© COPYRIGHT Apogee - CEMS JV, LLC

JOHN A. JURGIEL & ASSOCIATES, INC.

123 N. Main Street (636)757-3060 St. Charles, MO. 63301 Jurgiel.com

JURGIEL

JOHN A. JURGIEL & ASSOCIATES, INC.

/2

/2

:1

:2

P

M

AD101

OVERALL SECOND FLOOR DEMOLITION

PLAN

3 14RR

RENOVATE SPACE FOR

WHOLE HEALTH

1 JEFFERSON BARRACKS DR.,

ST LOUIS, MO 63125

MAY 28, 2021

BID DOCUMENTS

657-20-101JB19-335

TJS

NORTH

0 8 16 32

N

AREA OF WORK

KEY PLAN

SCALE: NO SCALE

Scale: 3/32" = 1'-0"

OVERALL SECOND FLOOR DEMOLITION PLAN

SCOPE OF WORK LEGEND

WALL LEGEND

S SS

P R

R

R.2 T V V.3

V.3U.1T.2T.1R.3

/2 AD102/2 AD102

MATCH LINE MATCH LINE

8'-3 1/2" 7'-0" 7'-0" 7'-0" 8'-3 1/2" 9"9"

20'-7 1/2"

1'-0 1/2"

13'-10 1/2" 21'-7" 1'-1"

/4

/4

K M N O P Q

R R.2 S T U V V.3

10.1

8.1

/1 AD102/1 AD102

MATCH LINE MATCH LINE

EXAM

2E25A

EXAM

2E25

OFFICE

2E23

WAITING

ROOM

2E26

OFFICE

2E27

OFFICE

2E22

TOILET

2E22A

TOILET

2E28

EXAM

2E29

TOILET

2E25B

TOILET

2E24

EXAM

2E21

OFFICE

2E20

CHASE

CH-E-1

OFFICE

2CO5

STORAGE

2CO6

ELEVATOR

NO. 2

E2

OFFICE

2CO8

OFFICE

2CO9

CONFERENCE

ROOM

2CO7

OFFICE

2CO3

THERAPY

2CO2

OFFICE

2CO4

CORRIDOR

H210

STAIR

S201

HAC

2E01

3 4 5 7

3 4 7

3 4 73 4 73 4 7

3 4 7 3 4 73 4 7

3 4 7

3 4 7

3 4 7

3 4 7 3 4 7

3 42

3 42

3 42

3 4

3 4 3 4

3 4 5 7

3 4

1'-0 1/2" 10'-9"

3'-1 1/2"

10'-10 1/2" 10'-8 1/2" 1'-1"

ELEV

LOBBY

H206

V.I.F.

9'-10"

V .I

.F

/8

V .I

.F

/8

V.I.F.

1'-10"

EXAM

2C11

PHONE CLO.

2C11A

EXAM

2C01B

OFFICE

2C10

IRM

2C10A

4'-0 1/2" 7'-8"

4" 3'-10"

19'-1 1/2" 18'-6" 18'-6" 13'-8 1/2" 4'-9 1/2" 15'-10"

/4

/4

/4

/2

/4

/2

/8

/8

/4

20'-7 1/2"

1'-0 1/2"

13'-10 1/2" 21'-7" 1 7/8"11 1/8"1'-1"

WAITING

2C01

RECEPTION

2C01A

11'-6"

2 HOUR FIRE SEPARATION

1 HOUR FIRE SEPARATION

SMOKE RATED

A. SEE SHEET A-001 FOR GENERAL NOTES.

B. DEMOLITION THAT REQUIRES SYSTEM SHUT

DOWNS FOR PART OF, OR ALL OF THE

FLOOR OR BUILDING IS TO BE COORDINATED

WITH THE COR AND TAKE PLACE AFTER

NORMAL BUSINESS HOURS IF DIRECTED BY

THE COR. SEE ENGINEERING DRAWINGS

FOR LOCATIONS AND SCOPE.

C. DEMOLITION THAT GENERATES SIGNIFICANT

NOISE OR VIBRATION (CUTTING, DRILLING,

CORING, ETC.) TO BE COORDINATED WITH

COR PRIOR TO START OF DEMOLITION. SEE

ENGINEERING DRAWINGS FOR LOCATIONS

AND SCOPE.

D. WHERE REMOVING CMU, CONCRETE, OR

CLAY TILE WALLS, ALL VOIDS AND HOLES

CREATED IN FLOOR SLAB TO BE FILLED IN

WITH SELF-LEVELING COMPOUND FLUSH

WITH EXISTING FLOOR SLAB LEVEL (TYP.).

E. WALL REMOVED THIS FLOOR ARE CLAY TILE

OR CLAY TILE WITH FURRING.

ICRA BARRIER LEGEND

LINE REPRESENTS DIAGRAMMED

LOCATION OF ICRA BARRIERS

SCOPE OF CONSTRUCTION

EXISTING WALL

DEMOLITION WALL

1151 Kildaire Farm Rd.

Suite 120 Raleigh, NC 27511 www.acg-pa.com (919)858-7420

108 Benton Lodge Road Suite B Summerville, SC 29485 www.cemsengineering.com (843)875-3637Project Mgr: Alex Kramer (APOGEE)

Joint Venture An Alliance for Success

# KEY NOTES:

Revisions: Date

Drawing Title

Approved: Project Director

Project Title

Location

VA PROJECT NUMBER

Building Number

Drawing Number

Dwg of

VA FORM 08-6231

Office of Construction and Facilities Management

CONSULTANTS: PROJECT MANAGER

SHEET NOTES:

Date Checked Drawn

FULLY SPRINKLERED

ACG Project Number

U.S. Department of Veterans Affairs# © COPYRIGHT Apogee - CEMS JV, LLC

JOHN A. JURGIEL & ASSOCIATES, INC.

123 N. Main Street (636)757-3060 St. Charles, MO. 63301 Jurgiel.com

JURGIEL

JOHN A. JURGIEL & ASSOCIATES, INC.

/2

/2

:1

:3

P

M

AD102

ENLARGED SECOND FLOOR

DEMOLITION PLAN

4 14RR

RENOVATE SPACE FOR

WHOLE HEALTH

1 JEFFERSON BARRACKS DR.,

ST LOUIS, MO 63125

MAY 28, 2021

BID DOCUMENTS

657-20-101JB19-335

TJS

N

AREA OF WORK

KEY PLAN

SCALE: NO SCALE

Scale: 1/8" = 1'-0"

ENLARGED SECOND FLOOR DEMOLITION PLAN - SOUTH

NORTH

0 4 8 16

Scale: 1/8" = 1'-0"

ENLARGED SECOND FLOOR DEMOLITION PLAN - NORTH

NORTH

0 4 8 16

1. REMOVE DOOR, FRAME, HARDWARE AND

ACCESSORIES.

2. REMOVE PLUMBING FIXTURES AND ALL ASSOCIATED

ACCESSORIES.

3. REMOVE FLOOR FINISHES.

4. REMOVE CEILING FINISHES, HARDWARE AND

ACCESSORIES.

5. REMOVE BUILT-IN CABINETS, STORAGE AND

CONTAINERS.

6. REMOVE CHASE. RELOCATE UTILITIES INSIDE PER

MEP DRAWINGS.

7. REMOVE CEILING TILES. GRID AND HARDWARE TO

REMAIN.

8. REMOVE SHOWER PAN AND WATERPROOFING

MEMBRANE. FLOOR TO BE SMOOTH AND LEVEL FOR

NEW FLOOR FINISH.

9. PROTECT DOOR FRAME AND HARDWARE

THROUGHOUT CONSTRUCTION. REPAIR ANY DAMAGE

TO DOOR OR FRAME AS PART OF PREPARATION FOR

NEW PAINTED FINISH.

10. ALL WALLS, FLOORS, AND CEILING FIXTURES ARE TO

BE REMOVED. SALVAGE MEP EQUIPMENT PER

ENGINEERING DRAWINGS.

11. INFECTION CONTROL BARRIER WALL TYPE "A".

12. INFECTION CONTROL BARRIER WALL TYPE "B".

13. INFECTION CONTROL BARRIER WALL TYPE "D".

14. REMOVE EXISTING DOOR, FRAME AND CONTROL

PANEL FOR DUMBWAITER. INFILL WITH NEW 2 HOUR

RATED SHAFTWALL ASSEMBLY.

WALL RATING LEGEND

SCOPE OF WORK LEGEND

WALL LEGEND

P R

R

R.2 T V V.1 V.2 V.3

V.3U.1T.2T.1R.3

7'-0" 7'-0" 7'-0"

HAC

2E01

/1 AC112

MATCH LINE

/1 AC112

MATCH LINE

/2

/8

20'-7 1/2" 7 1/2"

14'-3 1/2" 21'-7" 6 1/2"

3 1/4" 3 1/4"

9"

/4

/4

8'-3 1/2" 8'-3 1/2" 9"9"

1 2

OFFICE

2CO4

K M N O P Q

R R.1 R.2 S T U V V.1 V.2 V.3

10.1

8.1

13'-8 1/2" 4'-9 1/2"

3" 9 1/2" 10'-9" 3'-1 1/2" 10'-10 1/2" 10'-8 1/2"

6 1/2" 3 1/4"

3 1/4"

/2

/4

/2

/4

EXAM

2E25A

EXAM

2E25

OFFICE

2E23

WAITING

ROOM

2E26

OFFICE

2E27

OFFICE

2E22

TOILET

2E22A

TOILET

2E28

EXAM

2E29

TOILET

2E25B

TOILET

2E24

EXAM

2E21

OFFICE

2E20

CHASE

CH-E-1

OFFICE

2CO5

STORAGE

2CO6

OFFICE

2CO8

OFFICE

2CO9

CONFERENCE

ROOM

2CO7

THERAPY

2CO2

CORRIDOR

H210

HAC

2E01

3 3

3 3 3

ELEVATOR

NO. 2

E2

STAIR

S201

/1 AC112/1 AC112

MATCH LINE MATCH LINE

EXAM

2C11

PHONE CLO.

2C11A

WAITING

2C01

RECEPTION

2C01A

EXAM

2C01B

IRM

2C10A

/4

/4

/4

/2

/4

20'-7 1/2" 7 1/2"

14'-3 1/2" 21'-7" 6 1/2"

3 1/4" 3 1/4"

9"

19'-1 1/2" 18'-6" 18'-6" 15'-10"

1 2

1 2

1 2

1 2

OIT

2C10

OFFICE

2CO3

OFFICE

2CO4

2'x4' ACOUSTICAL TILE TO BE

DEMOLISHED

DEMOLITION CEILING LEGEND

GYPSUM BOARD CEILING TO

BE DEMOLISHED

DOWNLIGHT TO BE DEMOLISHED

EXIT SIGN TO BE REMOVED

2'x4' LAY-IN LIGHT FIXTURE TO

BE DEMOLISHED

SCOPE OF CONSTRUCTION

NOTE: SUB CEILING AND ALL ASSOCIATED

HARDWARE IS TO BE REMOVED. ANY FINISHES ON

THE UNDERSIDE OF THE STRUCTURE OR

STRUCTURAL SLAB ABOVE SUB CEILING IS TO BE

REMOVED. SUB CEILINGS EXISTS THROUGH ENTIRE

SPACE WITHIN SCOPE. COORDINATE WITH

ABATEMENT DRAWINGS.

EXISTING WALL

DEMOLITION WALL

1151 Kildaire Farm Rd.

Suite 120 Raleigh, NC 27511 www.acg-pa.com (919)858-7420

108 Benton Lodge Road Suite B Summerville, SC 29485 www.cemsengineering.com (843)875-3637Project Mgr: Alex Kramer (APOGEE)

Joint Venture An Alliance for Success

# KEY NOTES:

Revisions: Date

Drawing Title

Approved: Project Director

Project Title

Location

VA PROJECT NUMBER

Building Number

Drawing Number

Dwg of

VA FORM 08-6231

Office of Construction and Facilities Management

CONSULTANTS: PROJECT MANAGER

SHEET NOTES:

WALL RATING LEGEND

1 HR - FIRE SEPARATION

2 HR - FIRE SEPARATION

SMOKE RATED

Date Checked Drawn

FULLY SPRINKLERED

ACG Project Number

U.S. Department of Veterans Affairs#

S S S S

© COPYRIGHT Apogee - CEMS JV, LLC

JOHN A. JURGIEL & ASSOCIATES, INC.

123 N. Main Street (636)757-3060 St. Charles, MO. 63301 Jurgiel.com

JURGIEL

JOHN A. JURGIEL & ASSOCIATES, INC.

/2

/2

:1

:4

P

M

ADC112

ENLARGED SECOND FLOOR

REFLECTED CEILING DEMOLITION

PLAN

5 14RER

RENOVATE SPACE FOR

WHOLE HEALTH

1 JEFFERSON BARRACKS DR.,

ST LOUIS, MO 63125

MAY 28, 2021

BID DOCUMENTS

657-20-101JB19-335

TJS

N

AREA OF WORK

KEY PLAN

SCALE: NO SCALE

NORTH

0 4 8 16

NORTH

0 4 8 16

Scale: 1/8" = 1'-0"

ENLARGED REFLECTED CEILING DEMOLITION PLAN - SOUTH

Scale: 1/8" = 1'-0"

ENLARGED REFLECTED CEILING DEMOLITION PLAN - NORTH

1 CEILING THIS SPACE TO BE REMOVED. SALVAGE

GRID FOR REUSE. SALVAGE CEILING TILES AND

TURN OVER TO VA.

2 SEE MECHANICAL AND ELECTRICAL FOR

EQUIPMENT AND FIXTURES TO BE SALVAGED FOR

REUSE.

3 REMOVE CEILING AND ALL ASSOCIATED

HARDWARE, FIXTURES, AND EQUIPMENT. SEE

MECHANICAL, ELECTRICAL AND FIRE PROTECTION

FOR ANY ITEMS TO BE SALVAGED FOR REUSE.

SCOPE OF WORK LEGEND

WALL LEGEND

DNUP

A

A.3 B C C.1 D.1

D.1D.2

E F G H J K M N O P Q

R

R.2 S T U V

V.3U.1T.2T.1R.3

LL

C.2B.2B.1A.4

10.1

2E28

CLASSROOM

2E23

COPY AREA

2E24

OFFICE

2E21

WAITING

2E22

RECEPTION

2E11

MEDITATION

2E12

MASSAGE

2E13

EXAM

2E14

MEDS

CHIRO

EXAM

2E15

CHIRO

EXAM

2E16

2E17

CONSULT

2E10

ACUPUNCTURE

2E09

ACUPUNCTURE

CLEAN

UTILITY

2E08

2E07

SOILED

CHIRO

EXAM

2E06

CHIRO

EXAM

2E05

2E04

CONSULT

2E03

PAT TLT

2E02

PAT TLT

2E01

HAC

2E18

CONSULT

2E19

CONSULT

2E20

CONSULT

2C06

OFFICE

2C05

PROVIDER

OFFICE

2C02B

OFFICE

2C09

OPEN OFFICE

2C08

OPEN OFFICE

2C07B

WOMEN'S

RESTROOM

2C07A

MEN'S

RESTROOM

2E27

CLASSROOM

GROUP

ROOM 2A

2E25A

GROUP

ROOM 1A

2E26A

2C02A

OFFICE

2C03

OFFICE

2C04A

OFFICE

2C04B

OFFICE

H201

CORRIDOR

H203

CORRIDOR

H205

CORRIDOR

H207

CORRIDOR

2E26C

STORAGE

STORAGE

2E25C

4'-9 1/2" 13'-8 1/2" 18'-6" 18'-6" 19'-1 1/2" 18'-6" 19'-1 1/2" 18'-6" 18'-6" 13'-8 1/2" 4'-9 1/2"

/4

/4

/4

/2

/4

/2

/4

/2

/4

/2

/4

8'-3 1/2" 7'-0" 7'-0" 7'-0" 8'-3 1/2"

2E28

E

E

A

E

B

E

C

H204

E

C

E

B

E

A

H203

E

C

2C052C07B2C07A2C082C09

C

A

C

B

C

B

C

A

E

E

E

E

E

E

E

E

E

E

H201

E

E

E

E

E

E

E

E

E

STAIR S201

ELEV_

/1 A-102

/2 A-102

/1 A-102

/2 A-102

8'-3 1/2" 7'-0" 7'-0" 7'-0" 8'-3 1/2"

10'-8" 10'-10 1/2"

3'-1 1/2"

11'-6 1/2"

10'-9" 3'-1 1/2"

10'-10 1/2" 10'-8 1/2"

GROUP

ROOM 1B

2E26B

GROUP

ROOM 2B

2E25B

H204

CORRIDOR

H206

ELEV LOBBY

MATCH LINE MATCH LINE

2C03

A-501

A-502

A-502

AC113

EXAM

2C11

PHONE CLO.

2C11A

OPTICAL

SHOP

2C12

NURSE

STATION

2C13

EXAM

2C14

EXAM

2C15

MEN'S

TOILET

2C16

KITCHEN

2C17

MECH.

2C18

LAB

2C19

WAITING

ROOM

2C20

OFFICE

2C22

ALCOVE

2C21

TOILET

2C24

OFFICE

2C23

EXAM

2C25

TOILET

2C27

HSKP

2C28

STAIR

S202

OFFICE

2C29

WAITING

ALCOVE

H205A

WAITING

2C01

RECEPTION

2C01A

CORR.

H205A

CORR.

H205A

CORR.

H206

STAIR

S203

HSKP

2W36 TOILET

2W34

OFFICE

2W35

OFFICE

2W33

EXAM

2W32

EXAM

2W30

VEST.

2W29E

TOILET

2W29F

EXAM

2W29D

STOR.

2W29C

OFFICE

2W29B

STOR.

2W29A

OFFICE

2W29

EXAM

2W28C

EXAM

2W28B

EXAM

2W28A

EXAM

2W28

EXAM

2W27

OFFICE

2W26

MECH.

2W25

EXAM

2W24

UNISEX

TOILET

2W23

EXAM

2W22C

PHARM.

OFF.

2W22A

OXYGEN

STO.

2W22B

MED. RM.

2W22

CORR.

H208

OFFICE

2W21

UNISEX

TOILET

2W20

WAITING

2W19

OFFICE

2W18

TLT.

2W14

EXAM

2W16

EXAM

2W15

TOILET

2W14

OFFICE

2W13

OFFICE

2W12

TOILET

2W11

EXAM

2W10

EXAM

2W09

TLT.

2W08

EXAM

2W07

BREAKROOM

2W06

STORAGE

2W05

MED

PREP

2W04

TOILET

2W03

FAX

2W02

RECEPTION

2W01

CORR.

H207

CORR.

H209

IRM

2C10A

A-502

A-502

A-502

A-502

12 _____ A-502

A-501

SIM.

A-501

A-501

A-501

SIM.

SIM.

FAC

H210

EXAM

2C01B

OIT

2C10

2 HOUR FIRE SEPARATION

1 HOUR FIRE SEPARATION

SMOKE RATED

1. VERIFY EQUIPMENT, FURNITURE, AND

SYSTEMS FURNITURE ON EQUIPMENT PLANS.

2. SOME WORK TO BE CONDUCTED AFTER

HOURS AND ON WEEKENDS WHEN FACILITY IS

OFF PEAK OPERATING HOURS. COORDINATE

WITH COR FOR TIME AND DAYS. SEE

ENGINEERING DRAWINGS FOR LOCATIONS

AND SCOPE.

3. WORK CONDUCTED OUTSIDE MAIN SCOPE OF

CONSTRUCTION (IT, DATA, TELECOM) TO BE

DONE ON NIGHTS AND WEEKENDS WHEN

FACILITY IS OFF PEAK OPERATING HOURS.

COORDINATE WITH COR FOR TIMES AND

DAYS. SEE ENGINEERING DRAWINGS FOR

LOCATIONS AND SCOPE.

4. ALL MEANS OF EGRESS TO BE MAINTAINED AT

ALL TIMES DURING CONSTRUCTION. MINIMUM

CLEAR CORRIDOR WIDTH TO BE OBSERVED

DURING ALL CONSTRUCTION PHASES.

5. SEE PLANS FOR PARTITION TYPES AND

DIMENSIONS.

SCOPE OF CONSTRUCTION

NEW WALL, SEE

WALL TYPES

NEW DOOR, SEE

DOOR SCHEDULE

NEW TOILET NEW SINK

EXISTING

WALL

EXISTING

DOOR

1151 Kildaire Farm Rd.

Suite 120 Raleigh, NC 27511 www.acg-pa.com (919)858-7420

108 Benton Lodge Road Suite B Summerville, SC 29485 www.cemsengineering.com (843)875-3637Project Mgr: Alex Kramer (APOGEE)

Joint Venture An Alliance for Success

Revisions: Date

Drawing Title

Approved: Project Director

Project Title

Location

VA PROJECT NUMBER

Building Number

Drawing Number

Dwg of

VA FORM 08-6231

Office of Construction and Facilities Management

CONSULTANTS: PROJECT MANAGER

SHEET NOTES:

Date Checked Drawn

FULLY SPRINKLERED

ACG Project Number

U.S. Department of Veterans Affairs# © COPYRIGHT Apogee - CEMS JV, LLC

JOHN A. JURGIEL & ASSOCIATES, INC.

123 N. Main Street (636)757-3060 St. Charles, MO. 63301 Jurgiel.com

JURGIEL

JOHN A. JURGIEL & ASSOCIATES, INC.

/2

/2

:1

:2

P

M

A-101

OVERALL SECOND FLOOR PLAN

6 14RR

RENOVATE SPACE FOR

WHOLE HEALTH

1 JEFFERSON BARRACKS DR.,

ST LOUIS, MO 63125

MAY 28, 2021

BID DOCUMENTS

657-20-101JB19-335

TJS

N

AREA OF WORK

KEY PLAN

SCALE: NO SCALE

Scale: 3/32" = 1'-0"

OVERALL SECOND FLOOR PLAN

NORTH

0 8 16 32

WALL RATING LEGEND

SCOPE OF WORK LEGEND

CONSTRUCTION LEGEND

P

P R

R.2 T V

V.3U.1T.2T.1R.3

CONSULT

2E20

HAC

2E01

PAT TLT

2E02

PAT TLT

2E03

CONSULT

2E19

CONSULT

2E18

CONSULT

2E17

CONSULT

2E04

CHIRO

EXAM

2E05

CHIRO

EXAM

2E06

CHIRO

EXAM

2E16

CHIRO

EXAM

2E15

MEDS

2E14

SOILED

2E07

CLEAN

UTILITY

2E08

EXAM

2E13

ACUPUNCTURE

2E09

ACUPUNCTURE

2E10

MASSAGE

2E12

MEDITATION

2E11

OFFICE

2C04B

/4

E

E

E

E

E

E

E

E

E

H201

E

E

E

E

E

E

E

E

E

/2 A-102/2 A-102

MATCH LINE MATCH LINE

8'-3 1/2" 7'-0" 7'-0" 7'-0" 8'-3 1/2"

7'-5 3/8" 12'-7 3/8"

/8

/4

/8

/4

/2

7'-5"

/4

/4

/8

/8

/2

/4

/4

Maa4

A

Maa3

A Maa3

1 A

Maa3

1 A

Maa3

A

Maa3

A

Ma2

Maa3

A

Maa3

1 A

Maa3

A

Ma4

A

Ma3

A

Maa3

A

Maa3

A Maa3

A

Maa3

A

Maa4

A

Maa4

A

FEC

FEC

Maa4

A

Maa3

A

Maa3

1 A Maa4

A

Maa3

A

Maa3

A

Maa3

1 A

Maa3

A

Maa3

1 A

CORRIDOR

H201

Maa4

A

/2

/8

/8

/8

/8 " 5

/4

Ma4

A

Ma3

A

A-501

A-501

A-502

A-502

A-502

A-501

AC113

_____FHC

20'-7 1/2"

K M N O P Q

R R.2 S T U V V.3

10.1

DN

UP

GROUP

ROOM 2A

2E25A

COPY

AREA

2E23

OFFICE

2E24

RECEPTION

2E22

CHECK

IN KIOSK

2E21A

WAITING

2E21

CONSULT

2E20

HAC

2E01

OFFICE

2C02B

OPEN

OFFICE

2C08

MEN'S

RESTROOM

2C07A

WOMEN'S

RESTROOM

2C07B

OFFICE

2C06

CLASSROOM

2E28

CLASSROOM

2E27

GROUP

ROOM 1A

2E26A

STORAGE

2E26C

OFFICE

2C02A

OFFICE

2C04A

OFFICE

2C04B

13'-8 1/2" 4'-9 1/2"19'-1 1/2" 18'-6" 18'-6"

/4

/4

/4

/4

/2

/8

/8

/4

E

E

STORAGE

2E25C

OPEN

OFFICE

2C09

OFFICE

2C03

STAIR S201

PROVIDER

OFFICE

2C05

ELEV_

CORRIDOR

H205

2C09

C

A

C

B

C

A

C

B

2C08

2C07A 2C07B

2C05

C

E

H203

E

A

E

B

E

C

H204

E

C

E

A

E

B

2E28

E

1'-0 1/2"

10'-9"

3'-1 1/2"

10'-10 1/2" 10'-8 1/2"

1'-1"

/2

/1 A-102/1 A-102

MATCH LINE MATCH LINE

Maa3

A

Maa3

A

Maa3

A

Maa3

A Maa3

A

Ma2

Ma2

Maa3

A Maa3

A Maa3

A

Ma2

Ma2

Ma2

Ma0

Maa3

A

Maa3

A

Maa4

A

Maa3

A

Maa3

A

Ma2

Maa3

A

Maa4

A

Maa3

1 A

Maa4

A

Maa3

A

Maa3

A Ma0

Maa3

A

Maa3

A

Maa3

A

Maa4

A

Maa3

A

Maa3

A

Ma3

A

/2

/4

21'-2 3/4"

7'-4 3/8"

1'-0 3/4"

/4

/4

3'-9 1/2"

GROUP

ROOM 1B

2E26B

GROUP

ROOM 2B

2E25B

E Q

E Q

/2

/8

Ma3

A

1'-1"

16'-2"

11 1/2"

4'-2 1/4" 22'-9 3/4"

/8

/8

3'-9 1/2"

1'-2 3/4"

/8

/8

/2

7"

5'-2 3/8"

9'-2 1/4"

1'-2 3/8"

/2

/2

/2

7'-8 7/8"

145'-4 5/8" RADIUS

33333

FEC

Maa3

A

2C03

5 11

6 Maa4

A

Ma0

Maa3

A

CORRIDOR

H207 ELEV

LOBBY

H206

CORRIDOR

H203

CORRIDOR

H204

/4

FEC

A-401

A-401

A-501

A-501

A-501

A-501

A-501

A-501

A-501

A-501

A-501

A-501

A-501

A-501

3'-0" 7'-1 7/8" 5'-0"

AC113

AC113

AC113

Ma3

A

Ma3

A Ma3

A

WAITING

2C01

RECEPTION

2C01A

IRM

2C10A

Ma2

Ma3

A9 3'-0"

/4

R

/8

R=6'-1 0 1

/2

15'-10"

A-502

A-502

A-502

A-502

A-501

A-501

SIM.

SIM.

A-501

A-502

A-502

A-502

SIM.

FAC

H210

2E21

8'-4 1/4"

EXAM

2C01B

OIT

2C10

11'-6"

/4

2 HOUR FIRE SEPARATION

1 HOUR FIRE SEPARATION

SMOKE RATED

NEW WALL, SEE

WALL TYPES

NEW DOOR, SEE

DOOR SCHEDULE

NEW TOILET NEW SINK

EXISTING

WALL

EXISTING

DOOR

SCOPE OF CONSTRUCTION

ICRA BARRIER LEGEND

LINE REPRESENTS DIAGRAMMED

LOCATION OF ICRA BARRIERS

1. VERIFY EQUIPMENT, FURNITURE, AND

SYSTEMS FURNITURE ON EQUIPMENT PLANS.

2. SOME WORK TO BE CONDUCTED AFTER

HOURS AND ON WEEKENDS WHEN FACILITY IS

OFF PEAK OPERATING HOURS. COORDINATE

WITH COR FOR TIME AND DAYS. SEE

ENGINEERING DRAWINGS FOR LOCATIONS

AND SCOPE.

3. WORK CONDUCTED OUTSIDE MAIN SCOPE OF

CONSTRUCTION (IT, DATA, TELECOM) TO BE

DONE ON NIGHTS AND WEEKENDS WHEN

FACILITY IS OFF PEAK OPERATING HOURS.

COORDINATE WITH COR FOR TIMES AND

DAYS. SEE ENGINEERING DRAWINGS FOR

LOCATIONS AND SCOPE.

4. ALL MEANS OF EGRESS TO BE MAINTAINED AT

ALL TIMES DURING CONSTRUCTION. MINIMUM

CLEAR CORRIDOR WIDTH TO BE OBSERVED

DURING ALL CONSTRUCTION PHASES.

5. SEE PLANS FOR PARTITION TYPES AND

DIMENSIONS.

1151 Kildaire Farm Rd.

Suite 120 Raleigh, NC 27511 www.acg-pa.com (919)858-7420

108 Benton Lodge Road Suite B Summerville, SC 29485 www.cemsengineering.com (843)875-3637Project Mgr: Alex Kramer (APOGEE)

Joint Venture An Alliance for Success

# KEY NOTES:

Revisions: Date

Drawing Title

Approved: Project Director

Project Title

Location

VA PROJECT NUMBER

Building Number

Drawing Number

Dwg of

VA FORM 08-6231

Office of Construction and Facilities Management

CONSULTANTS: PROJECT MANAGER

SHEET NOTES:

Date Checked Drawn

FULLY SPRINKLERED

ACG Project Number

U.S. Department of Veterans Affairs# © COPYRIGHT Apogee - CEMS JV, LLC

JOHN A. JURGIEL & ASSOCIATES, INC.

123 N. Main Street (636)757-3060 St. Charles, MO. 63301 Jurgiel.com

JURGIEL

JOHN A. JURGIEL & ASSOCIATES, INC.

/2

/2

:1

:2

P

M

A-102

ENLARGED SECOND FLOOR PLAN

7 14RR

RENOVATE SPACE FOR

WHOLE HEALTH

1 JEFFERSON BARRACKS DR.,

ST LOUIS, MO 63125

MAY 28, 2021

BID DOCUMENTS

657-20-101JB19-335

TJS

N

AREA OF WORK

KEY PLAN

SCALE: NO SCALE

Scale: 1/8" = 1'-0"

ENLARGED SECOND FLOOR PLAN - SOUTH

NORTH

0 4 8 16

Scale: 1/8" = 1'-0"

ENLARGED SECOND FLOOR PLAN - NORTH

NORTH

0 4 8 16

WALL RATING LEGEND

SCOPE OF WORK LEGEND

CONSTRUCTION LEGEND

1 ALIGN NEW FINISHES TO EXISTING.

2 EXISTING SHAFT TO REMAIN.

3 NEW RADIATOR AND COVER.

4 OPERABLE PARTITIONS WITH 4'-0"H CENTERED

MARKERBOARD ON BOTH SIDES

5 INFECTION CONTROL BARRIER WALL TYPE "A".

6 PORTION OF FINISH WORK OUTSIDE OF INFECTION

CONTROL BARRIER TO BE DONE AFTER PEAK

OPERATING HOURS. PROVIDE TEMPORARY TYPE D

INFECTION CONTROL BARRIER OVER DOOR DURING

THIS PORTION OF CONSTRUCTION. THIS PORTION

OF CORRIDOR TO REMAIN OPERATIONAL AT ALL

OTHER TIMES.

7 PATCH AND REPAIR ABANDONED FLOOR

PENETRATIONS FOR SMOOTH SURFACE TO

RECEIVE NEW FLOOR FINISH.

8 INFILL DUMBWAITER OPENING WITH NEW 2 HOUR

RATED SHAFT WALL. FIRE CAULK AND SEAL ALL

JOINTS PRIOR TO NEW FURRING INSTALLATION.

9 NEW WATER COOLER WITH BOTTLE FILLING

STATION.

10 INFECTION CONTROL BARRIER WALL TYPE "B".

11 INFECTION CONTROL BARRIER WALL TYPE "D".

OS OS OS OS OS OS

OS

OS

OS

OS

OS

OS

OS

OS

OS

OS

OPEN

OFFICE

2C09

OPEN

OFFICE

2C08

MEN'S

RESTROOM

2C07A

WOMEN'S

RESTROOM

2C07B

OFFICE

2C02A

OFFICE

2C02B

OFFICE

2C03

OFFICE

2C04A

OFFICE

2C04B

CORRIDOR

H207

ELEV

LOBBY

H206

PROVIDER

OFFICE

2C05

OFFICE

2C06

WAITING

2E21

COPY

AREA

2E23

OFFICE

2E24

GROUP

ROOM 2A

2E25A

GROUP

ROOM 1A

2E26A

CORRIDOR

H205

CLASSROOM

2E27

CLASSROOM

2E28

CORRIDOR

H202

CONSULT

2E20

HAC

2E01

PAT TLT

2E02 CONSULT

2E19

CONSULT

2E18

PAT TLT

2E03

CONSULT

2E04

CONSULT

2E17

CHIRO

EXAM

2E16

CHIRO

EXAM

2E05

CHIRO

EXAM

2E06 CHIRO

EXAM

2E15

MEDS

2E14

SOILED

2E07

CLEAN

UTILITY

2E08

EXAM

2E13

ACUPUNCTURE

2E09

ACUPUNCTURE

2E10

MEDITATION

2E11

MASSAGE

2E12

CORRIDOR

H201

/2 AC112

/1 AC112

/2 AC112

/1 AC112

GROUP

ROOM 1B

2E26B

GROUP

ROOM 2B

2E25B

CORRIDOR

H204

STAIR

S201

H208

OPERABLE

PARTITION

OPERABLE

PARTITION

OPTICAL

SHOP

2C12

NURSE

STATION

2C13

MEN'S

TOILET

2C16

KITCHEN

2C17

MECH.

2C18

LAB

2C19

WAITING

ROOM

2C20

OFFICE

2C22

ALCOVE

2C21

TOILET

2C24

OFFICE

2C23

EXAM

2C25

TOILET

2C27

HSKP

2C28

STAIR

S202

OFFICE

2C29

WAITING

ALCOVE

H205A

WAITING

2C01

RECEPTION

2C01A

CORR.

H205A

CORR.

H205A

CORR.

H206

STAIR

S203

HSKP

2W36 TOILET

2W34

OFFICE

2W35

OFFICE

2W33

EXAM

2W32

EXAM

2W30

VEST.

2W29E

TOILET

2W29F

EXAM

2W29D

STOR.

2W29C

OFFICE

2W29B

STOR.

2W29A

OFFICE

2W29

EXAM

2W28C

EXAM

2W28B

EXAM

2W28A

EXAM

2W28

EXAM

2W27

OFFICE

2W26

MECH.

2W25

EXAM

2W24

UNISEX

TOILET

2W23

EXAM

2W22C

PHARM.

OFF.

2W22A

OXYGEN

STO.

2W22B

MED. RM.

2W22

CORR.

H208

OFFICE

2W21

UNISEX

TOILET

2W20

WAITING

2W19

OFFICE

2W18

TLT.

2W14

EXAM

2W16

EXAM

2W15

TOILET

2W14

OFFICE

2W13

OFFICE

2W12

TOILET

2W11

EXAM

2W10

EXAM

2W09

TLT.

2W08

EXAM

2W07

BREAKROOM

2W06

STORAGE

2W05

MED

PREP

2W04

TOILET

2W03

FAX

2W02

RECEPTION

2W01

CORR.

H209

EXAM

2C11

PHONE CLO.

2C11A

IRM

2C10A

F2225

F2225

F2225

F2225

F2225

EXAM

2C01B

OIT

2C10

REFLECTED CEILING PLAN

LEGEND

CURTAIN TRACK

2'x2' LAY-IN LED

SUPPLY DIFFUSER

RETURN GRILL

DOWN LIGHT

FIXTURE

EXIT SIGN (SHADED

AREA INDICATES

DIRECTION OF

EGRESS)

DENOTES GWB

SOFFIT/CEILING

E Q

B

EQ. A

SPRINKLER HEAD

ATC

8'-0"

CEILING HEIGHT

DESIGNATION

(WHEN HEIGHT

VARIES FROM

TYPICAL)

CONTRACTOR TO MEASURE EACH CEILING AREA AND

ESTABLISH A CEILING LAYOUT TO BALANCE BORDER

WIDTHS AT OPPOSITE EDGES OF EACH ROOM. TILES

LESS THAN 6" ON ANY EDGE ARE NOT ACCEPTABLE.

2'x4' LAY-IN LED

EXHAUST DIFFUSER

PENDANT LIGHT

SCOPE OF CONSTRUCTION

A. SEE SHEET AC112 FOR ENLARGED PLAN AND

DETAIL REFERENCES.

1151 Kildaire Farm Rd.

Suite 120 Raleigh, NC 27511 www.acg-pa.com (919)858-7420

108 Benton Lodge Road Suite B Summerville, SC 29485 www.cemsengineering.com (843)875-3637Project Mgr: Alex Kramer (APOGEE)

Joint Venture An Alliance for Success

Revisions: Date

Drawing Title

Approved: Project Director

Project Title

Location

VA PROJECT NUMBER

Building Number

Drawing Number

Dwg of

VA FORM 08-6231

Office of Construction and Facilities Management

CONSULTANTS: PROJECT MANAGER

SHEET NOTES:

WALL RATING LEGEND

1 HR - FIRE SEPARATION

2 HR - FIRE SEPARATION

SMOKE RATED

Date Checked Drawn

FULLY SPRINKLERED

ACG Project Number

U.S. Department of Veterans Affairs#

S S S S

© COPYRIGHT Apogee - CEMS JV, LLC

JOHN A. JURGIEL & ASSOCIATES, INC.

123 N. Main Street (636)757-3060 St. Charles, MO. 63301 Jurgiel.com

JURGIEL

JOHN A. JURGIEL & ASSOCIATES, INC.

/2

/2

:1

:5

P

M

AC111

OVERALL SECOND FLOOR REFLECTED

CEILING PLAN

8 14RR

RENOVATE SPACE FOR

WHOLE HEALTH

1 JEFFERSON BARRACKS DR.,

ST LOUIS, MO 63125

MAY 28, 2021

BID DOCUMENTS

657-20-101JB19-335

TJS

N

AREA OF WORK

KEY PLAN

SCALE: NO SCALE

Scale: 3/32" = 1'-0"

OVERALL SECOND FLOOR REFLECTED CEILING PLAN

NORTH

0 8 16 32

SCOPE OF WORK LEGEND

OS

OS

OS OS OS OS OS OS

OS

OS

OS

OS

OS

OS

S SS

P

R

R.2 T V

V.3U.1T.2T.1R.3

CONSULT

2E20

HAC

2E01

PAT TLT

2E02

CONSULT

2E19

CONSULT

2E18

PAT TLT

2E03

CONSULT

2E04

CONSULT

2E17

CHIRO

EXAM

2E16

CHIRO

EXAM

2E05

CORRIDOR

H202

CHIRO

EXAM

2E15

CHIRO

EXAM

2E06

SOILED

2E07 MEDS

2E14

EXAM

2E13

CLEAN

UTILITY

2E08

ACUPUNCTURE

2E09

ACUPUNCTURE

2E10

CORRIDOR

H201

MASSAGE

2E12

MEDITATION

2E11

8' - 4"

ACT

2x2

8' - 4"

ACT

2x2

8' - 4"

ACT

2x2

8' - 4"

ACT

2x2

8' - 4"

ACT

2x2

8' - 4"

ACT

2x2

8' - 4"

ACT

2x2

8' - 4"

ACT

2x2

8' - 4"

ACT

2x2

8' - 4"

ACT

2x2

8' - 4"

ACT

2x2

8' - 4"

ACT

2x2

8' - 4"

ACT

2x2

8' - 4"

ACT

2x2

8' - 4"

ACT

2x2

8' - 4"

ACT

2x2

8'-3 1/2" 7'-0" 7'-0" 7'-0" 8'-3 1/2"

/2 AC112/2 AC112

MATCH LINE MATCH LINE

8' - 4"

ACT

2x2

8' - 4"

ACT

2x2

9' - 0"

GYP

9' - 0"

GYP

9' - 0"

GYP

9' - 0"

GYP

8' - 4"

ACT

2x2

8' - 4"

ACT

2x2

9' - 0"

GYP

9' - 0"

GYP

9' - 0"

GYP

9' - 0"

GYP

9' - 0"

GYP

9' - 0"

GYP

9' - 0"

GYP

9' - 0"

GYP

9' - 0"

GYP

AC113

K M N O P Q

R R.1 S T U V V.3

10.1

/4

/2

/4

/2

/4

/2

13'-8 1/2" 4'-9 1/2"

OPEN

OFFICE

2C08

MEN'S

RESTROOM

2C07A

WOMEN'S

RESTROOM

2C07B

CORRIDOR

H207

PROVIDER

OFFICE

2C05

OFFICE

2C06

CHECK

IN KIOSK

2E21A

ELEV

LOBBY

H206

WAITING

2E21

RECEPTION

2E22

CORRIDOR

H203

COPY

AREA

2E23

OFFICE

2E24

GROUP

ROOM 2A

2E25A

GROUP

ROOM 1A

2E26A

STORAGE

2E26C

STORAGE

2E25C

CORRIDOR

H205

CLASSROOM

2E27

CLASSROOM

2E28

OFFICE

2C02A

OFFICE

2C02B

OFFICE

2C03

CORRIDOR

H207

OFFICE

2C04A

OFFICE

2C04B

WAITING

2E21

CONSULT

2E20

HAC

2E01

8' - 4"

ACT

2x2

8' - 4"

ACT

2x2

/4

19'-1 1/2" 18'-6" 18'-6"

/1 AC112/1 AC112

MATCH LINE MATCH LINE

OPEN

OFFICE

2C09

8' - 4"

ACT

2x2

9' - 0"

GYP

9' - 0"

GYP

9' - 0"

GYP

8' - 4"

ACT

2x2

9' - 0"

GYP

8' - 4"

ACT

2x2

9' - 0"

GYP

GROUP

ROOM 1B

2E26B

9' - 0"

GYP

9' - 0"

GYP

8' - 4"

ACT

2x2 GROUP

ROOM 2B

2E25B

9' - 0"

GYP

8' - 4"

ACT

2x2

9' - 0"

GYP

8' - 4"

ACT

2x2

9' - 0"

GYP

9' - 0"

GYP

9' - 0"

GYP

9' - 0"

GYP

8' - 4"

ACT

2x2

9' - 0"

GYP

9' - 0"

GYP

9' - 0"

GYP

8' - 4"

ACT

2x2

9' - 0"

GYP

8' - 4"

ACT

2x2

9' - 0"

GYP

8' - 4"

ACT

2x2

8' - 4"

ACT

2x2

9' - 0"

GYP

8' - 4"

ACT

2x2

9' - 0"

GYP

9' - 0"

GYP

9' - 0"

GYP

8' - 3"

ACT

2x2

CORRIDOR

H204

8' - 0"

GYP

8' - 0"

GYP

8' - 4"

ACT

2x2

8' - 4"

ACT

2x2

9' - 0"

GYP

8' - 4"

ACT

2x2

8' - 4"

ACT

2x2

9' - 0"

GYP

9' - 0"

GYP

9' - 0"

GYP

9' - 0"

GYP

8' - 3"

ACT

2x2

8' - 3"

ACT

2x2

9' - 0"

GYP

9' - 0"

GYP

9' - 0"

GYP

8' - 4"

ACT

2x2

9' - 0"

GYP

9' - 0"

GYP

9' - 0"

GYP

9' - 0"

GYP

9' - 0"

GYP8' - 4"

ACT

2x2

8' - 4"

ACT

2x2

7' - 6"

GYP

8' - 3"

ACT

2x2

8' - 4"

ACT

2x2

9' - 0"

GYP

9' - 0"

GYP

8' - 4"

ACT

2x2

8' - 4"

ACT

2x2

9' - 0"

GYP

7' - 6"

GYP

8' - 2"

GYP

OPERABLE

PARTITION

OPERABLE

PARTITION

AC113

A-401

A-401

A-401

AC113

AC113

AC113

AC113

IRM

2C10A

EXAM

2C11

PHONE CLO.

2C11A

WAITING

2C01

RECEPTION

2C01A

F2225

F2225

F2225

F2225

F2225

F2225

A-401

A-401

SIM.

A-401

FAC

H210

EXAM

2C01B

OIT

2C10

NO CEILING THIS

SPACE

2 HOUR FIRE SEPARATION

1 HOUR FIRE SEPARATION

SMOKE RATED

REFLECTED CEILING PLAN

LEGEND

CURTAIN TRACK

2'x2' LAY-IN LED

SUPPLY DIFFUSER

RETURN GRILL

DOWN LIGHT

FIXTURE

EXIT SIGN (SHADED

AREA INDICATES

DIRECTION OF

EGRESS)

DENOTES GWB

SOFFIT/CEILING

E Q

B

EQ. A

SPRINKLER HEAD

ATC

8'-0"

CEILING HEIGHT

DESIGNATION

(WHEN HEIGHT

VARIES FROM

TYPICAL)

CONTRACTOR TO MEASURE EACH CEILING AREA AND

ESTABLISH A CEILING LAYOUT TO BALANCE BORDER

WIDTHS AT OPPOSITE EDGES OF EACH ROOM. TILES

LESS THAN 6" ON ANY EDGE ARE NOT ACCEPTABLE.

2'x4' LAY-IN LED

EXHAUST DIFFUSER

PENDANT LIGHT

SCOPE OF CONSTRUCTION

1151 Kildaire Farm Rd.

Suite 120 Raleigh, NC 27511 www.acg-pa.com (919)858-7420

108 Benton Lodge Road Suite B Summerville, SC 29485 www.cemsengineering.com (843)875-3637Project Mgr: Alex Kramer (APOGEE)

Joint Venture An Alliance for Success

Revisions: Date

Drawing Title

Approved: Project Director

Project Title

Location

VA PROJECT NUMBER

Building Number

Drawing Number

Dwg of

VA FORM 08-6231

Office of Construction and Facilities Management

CONSULTANTS: PROJECT MANAGER

Date Checked Drawn

FULLY SPRINKLERED

ACG Project Number

U.S. Department of Veterans Affairs# © COPYRIGHT Apogee - CEMS JV, LLC

JOHN A. JURGIEL & ASSOCIATES, INC.

123 N. Main Street (636)757-3060 St. Charles, MO. 63301 Jurgiel.com

JURGIEL

JOHN A. JURGIEL & ASSOCIATES, INC.

/2

/2

:1

:0

P

M

AC112

ENLARGED SECOND FLOOR

REFLECTED CEILING PLAN

9 14RR

RENOVATE SPACE FOR

WHOLE HEALTH

1 JEFFERSON BARRACKS DR.,

ST LOUIS, MO 63125

MAY 28, 2021

BID DOCUMENTS

657-20-101JB19-335

TJS

N

AREA OF WORK

KEY PLAN

SCALE: NO SCALE

NORTH

0 4 8 16

NORTH

0 4 8 16

Scale: 1/8" = 1'-0"

ENLARGED SECOND FLOOR REFLECTED CEILING PLAN - SOUTH

Scale: 1/8" = 1'-0"

ENLARGED SECOND FLOOR REFLECTED CEILING PLAN - NORTH

WALL RATING LEGEND

SCOPE OF WORK LEGEND

SOFFIT LIGHTING - SEE ELECTRICAL

EXISTING CONCRETE BEAM

5/8" GYP. BD. ON 3 5/8" MTL STUDS

5/8" GYP. BD. BOTH SIDES 3 5/8" MTL.

STUDS TO BOTTOM OF FLOORING

ABOVE. BRACE TO STRUCTURE.

ACT CEILING AND GRID - SEE

REFLECTED CEILING PLANS.

SOFFIT

8'-0"

SOFFIT EDGE

7'-6"

ACT CEILING

8'-4"

DOOR - SEE SCHED.

R R.2

ACT CEILING

5/8" GYP. BD. ON

3 5/8" MTL. STUD

SOFFIT

9'-0"

SOFFIT EDGE

8'-3"

EXISTING GLAZING

EXISTING CONCRETE BEAM

EDGE OF GYP. BD., BEYOND

V V.2 V.3

ACT CEILING

5/8" GYP. BD. ON

3 5/8" MTL. STUD

SOFFIT

9'-0"

SOFFIT EDGE

8'-3"

EXISTING GLAZING

EXISTING CONCRETE BEAM

1'-8 3/4"

3 5/8" MTL STUDS TO

BOTTOM OF STRUCTURE

5/8" GYP. BD. ON 3 5/8"

MTL. STUDS

ACT CEILING

8'-4"

SOFFIT

7'-6" 1'-0 1/2"

5/8" GYP. BD. ON 3 5/8"

MTL. STUDS

ACT CEILING

8'-4"

SOFFIT

7'-6"

3 5/8" MTL. STUD TO BOTTOM

OF STRUCTURE

5/8" GYP. BD.

4'-0"

DUCTWORK - SEE

MECHANICAL

EXISTING CONCRETE BEAM

5/8" GYP. BD. ON 3 5/8"

MTL. STUDS

ACT CEILING AND GRID - SEE

REFLECTED CEILING PLANS.

ACT CEILING

8'-4"

SOFFIT

7'-6"

ACT CEILING

8'-4"

PARTITION SOFFIT

8'-2"

OPERABLE PARTITION,

BEYOND

PARTITION GLIDING TRACK

STRUCTURAL STEEL T - SEE STRUCT.

STEEL L CHANNEL BRACING - SEE STRUCT.

3 5/8" MTL. STUD TO BOTTOM OF STRUCTURE

5/8" GYP. BD.

T Y

P

4'-4 3/4"

CEILING SYSTEM - REF

TO RCP FOR TYPE AND

HEIGHT

F.R.T. WOOD

BLOCKING

MTL. STUD BRACING

TO STRUCTURE ABOVE

AT SPLICES AND

WHERE

RECOMMENDED BY

MANUFACTURER

1151 Kildaire Farm Rd.

Suite 120 Raleigh, NC 27511 www.acg-pa.com (919)858-7420

108 Benton Lodge Road Suite B Summerville, SC 29485 www.cemsengineering.com (843)875-3637Project Mgr: Alex Kramer (APOGEE)

Joint Venture An Alliance for Success

Revisions: Date

Drawing Title

Approved: Project Director

Project Title

Location

VA PROJECT NUMBER

Building Number

Drawing Number

Dwg of

VA FORM 08-6231

Office of Construction and Facilities Management

CONSULTANTS: PROJECT MANAGER

Date Checked Drawn

FULLY SPRINKLERED

ACG Project Number

U.S. Department of Veterans Affairs# © COPYRIGHT Apogee - CEMS JV, LLC

JOHN A. JURGIEL & ASSOCIATES, INC.

123 N. Main Street (636)757-3060 St. Charles, MO. 63301 Jurgiel.com

JURGIEL

JOHN A. JURGIEL & ASSOCIATES, INC.

/2

/2

:1

:1

P

M

AC113

ENLARGED CEILING SECTIONS

10 14RR

RENOVATE SPACE FOR

WHOLE HEALTH

1 JEFFERSON BARRACKS DR.,

ST LOUIS, MO 63125

MAY 28, 2021

BID DOCUMENTS

657-20-101JB19-335

TJS

Scale: 3/4" = 1'-0"

SOFFIT SECTION @ CLASSROOM

Scale: 3/4" = 1'-0"

SOFFIT SECTION @ CORRIDOR WINDOW

Scale: 3/4" = 1'-0"

SOFFIT SECTION @ WINDOW

Scale: 3/4" = 1'-0"

SOFFIT SECTION (NARROW) @ RECEPTION

Scale: 3/4" = 1'-0"

SOFFIT SECTION (WIDE) @ RECEPTION

Scale: 3/4" = 1'-0"

SOFFIT SECTION @ KIOSK

Scale: 3/4" = 1'-0"

SECTION @ MOVABLE PARTITION

Scale: 1 1/2" = 1'-0"

CUBICLE CURTAIN

T

CHECK

IN KIOSK

2E21A

/2

/2

/2

CORRIDOR

H203

R=6'-10 1/2"

/8

8'-4 3/8"

Ma3

A

Ma3

A

Ma3

A

PATCH AND REPAIR

EXISTING GYP. BD. FINISH

TO REMAIN FOR LIKE NEW

SURFACE TO RECEIVE

NEW PAINTED FINISH, SEE

INTERIORS SHEET.

T

V V.1 V.2 V.3

COPY

AREA

2E23

OFFICE

2E24

RECEPTION

2E22

E

/2

12'-0"

7"

/4

5'-2 3/8"

7'-8 7/8"

CORRIDOR

H203

5'-10 7/8"

/8

10'-9"

/8

/4

/8

/4

Ma2

Maa4

A

Maa3

A Maa3

A

Maa3

A

Maa3

A

Ma2

Ma3

A

Maa3

A

PATCH AND REPAIR

EXISTING GYP. BD. FINISH

TO REMAIN FOR LIKE NEW

SURFACE TO RECEIVE

NEW PAINTED FINISH, SEE

INTERIORS SHEET.

T U V

T V V.1 V.2 V.3

AC113

AC113

AC113

SIM.

COPY

AREA

2E23

OFFICE

2E24

RECEPTION

2E22

CORRIDOR

H203

A.F.F.8' - 4"A.F.F.7' - 6"

A.F.F.8' - 4"

A.F.F.8' - 3"

A.F.F.8' - 4"

A.F.F.7' - 6"

A.F.F.7' - 6"

R

/2

R

/2

9'-9 1/4"

/4

4'-0"

/2

1'-7 3/4"

/4

16.7°

17.3°

19.5°

.1

2'-8 3/4"

/4

EQ. EQ.

T

T

AC113

A.F.F.7' - 6"

A.F.F.8' - 3"

CORRIDOR

H203

R=6'-10 1/2"

8'-4 3/8"

/8

CHECK

IN KIOSK

2E21A

T

T

AC113

A.F.F.8' - 0"

A.F.F.8' - 4"

CORRIDOR

H205

GROUP

ROOM 1B

2E26B

GROUP

ROOM 1A

2E26A

A.F.F.8' - 4"

A.F.F.8' - 4"

A.F.F.7' - 6"

3'-9 1/4"

/2

2'-3 3/4" 1'-1 7/8"

/4

REFLECTED CEILING PLAN

LEGEND

CURTAIN TRACK

2'x2' LAY-IN LED

SUPPLY DIFFUSER

RETURN GRILL

DOWN LIGHT

FIXTURE

EXIT SIGN (SHADED

AREA INDICATES

DIRECTION OF

EGRESS)

DENOTES GWB

SOFFIT/CEILING

E Q

B

EQ. A

SPRINKLER HEAD

ATC

8'-0"

CEILING HEIGHT

DESIGNATION

(WHEN HEIGHT

VARIES FROM

TYPICAL)

CONTRACTOR TO MEASURE EACH CEILING AREA AND

ESTABLISH A CEILING LAYOUT TO BALANCE BORDER

WIDTHS AT OPPOSITE EDGES OF EACH ROOM. TILES

LESS THAN 6" ON ANY EDGE ARE NOT ACCEPTABLE.

2'x4' LAY-IN LED

EXHAUST DIFFUSER

PENDANT LIGHT

A.F.F.8' - 3"

A.F.F.8' - 4"

A.F.F.9' - 0"

/8

8 7/8" 3'-3" 8 7/8"

/2

1151 Kildaire Farm Rd.

Suite 120 Raleigh, NC 27511 www.acg-pa.com (919)858-7420

108 Benton Lodge Road Suite B Summerville, SC 29485 www.cemsengineering.com (843)875-3637Project Mgr: Alex Kramer (APOGEE)

Joint Venture An Alliance for Success

Revisions: Date

Drawing Title

Approved: Project Director

Project Title

Location

VA PROJECT NUMBER

Building Number

Drawing Number

Dwg of

VA FORM 08-6231

Office of Construction and Facilities Management

CONSULTANTS: PROJECT MANAGER

Date Checked Drawn

FULLY SPRINKLERED

ACG Project Number

U.S. Department of Veterans Affairs# © COPYRIGHT Apogee - CEMS JV, LLC

JOHN A. JURGIEL & ASSOCIATES, INC.

123 N. Main Street (636)757-3060 St. Charles, MO. 63301 Jurgiel.com

JURGIEL

JOHN A. JURGIEL & ASSOCIATES, INC.

/2

/2

:1

:3

P

M

A-401

ENLARGED PLANS AND ENLARGED

CEILING PLANS

11 14RR

RENOVATE SPACE FOR

WHOLE HEALTH

1 JEFFERSON BARRACKS DR.,

ST LOUIS, MO 63125

MAY 28, 2021

BID DOCUMENTS

657-20-101JB19-335

TJS

Scale: 1/2" = 1'-0"

ENLARGED SECOND FLOOR PLAN - CHECK-IN KIOSK

Scale: 1/2" = 1'-0"

ENLARGED SECOND FLOOR PLAN - RECEPTION DESK

Scale: 1/2" = 1'-0"

ENLARGED CEILING PLAN @ RECEPTION AREA

Scale: 1/2" = 1'-0"

ENLARGED CEILING PLAN @ CHECK-IN KIOSK

Scale: 1/2" = 1'-0"

ENLARGED CEILING PLAN @ CLASSROOM

Scale: 1/2" = 1'-0"

ENLARGED CEILING PLAN @ LIGHT WELL

M

8.1

1'-6 1/2"

/4

EXISTING CONCRETE

COLUMN. SEE

STRUCTURAL

EXISTING PARTITION

CORNER GUARD, TYP.

5/8" GYP. BD. ON 2 1/2"

MTL. STUD

N

8.1

/4

EXISTING CONCRETE

COLUMN. SEE

STRUCTURAL

5/8" GYP. BD. ON 2 1/2"

MTL. STUD

ACOUSTICAL

SOUND BATTS

1'-9" 1'-2 3/4"

5/8" GYP. BD. ON 7/8"

MTL. STUD

10.1

/8

5/8" GYP. BD. ON

BOTH SIDES 4"

MTL. STUD

1/2" WHITE PLASTIC

REVEAL MOULDING,

PREP SURFACES

FOR SMOOTH GAP

FREE INSTALLATION,

BOTH SIDES OF

OPENING

5/8" GYP. BD. ON 2 1/2"

MTL. STUDS

EXISTING PARTITION

M

CORNER GUARD, TYP.

5/8" GYP. BD. ON 7/8"

HAT CHAN.

5/8" GYP. BD. ON 2 1/2"

MTL. STUD

EXISTING CONCRETE

COLUMN. SEE STRUCT.

P

5/8" GYP. BD. ON

2 1/2" MTL. STUDS

CORNER GUARD,

TYP.

EXISTING CONCRETE

COLUMN. SEE STRUCT.

T

1'-3 1/4"

5/8" GYP. BD.

BOTH SIDES OF

4" MTL. STUDS

5/8" GYP. BD. BOTH

SIDES OF 3 5/8" MTL.

STUDS

CORNER GUARD, TYP.

5/8" GYP. BD. ON 7/8"

HAT CHAN.

5/8" GYP. BD. BOTH

SIDES OF 3 5/8" MTL.

STUDS

V V.1

1'-1 3/4"

CORNER GUARD, TYP.

5/8" GYP. BD. ON

3 5/8" MTL. STUD

PIPING. SEE

PLUMBING

T

9 5/8" 11 1/2"

/8

/8

/4

/8

/8

EXISTING CONCRETE

COLUMN, SEE

STRUCT.

CORNER GUARD, TYP.

5/8" GYP. BD. BOTH

SIDES OF 3 5/8" MTL.

STUDS

5/8" GYP. BD. ON 2 1/2"

MTL. STUD

5/8" GYP. BD. BOTH SIDES

OF 3 5/8" MTL. STUDS

/2

V V.1

/4

/8

/2

/8

10" 1 1/2"

CORNER GUARD, TYP.

5/8" GYP. BD. ON 2 1/2"

MTL. STUDS

EXISTING CONCRETE

COLUMN. SEE STRUCT.

5/8" GYP. BD. ON BOTH

SIDES OF 3 5/8" MTL.

STUDS

6"

5/8" GYP. BD. BOTH

SIDES OF 3 5/8" MTL.

STUDS

EXISTING 2-HR.

SHAFT WALL TO

REMAIN

T

/8

/8

/4

11 1/8" 11" 6 1/4"

CORNER GUARD, TYP.

EXISTING CONCRETE

COLUMN. SEE STRUCT.

5/8" GYP. BD. ON 3 5/8"

MTL. STUDS

2 LAYERS 5/8" GYP.

BD. ON C-H STUDS

ON 1" GYP. BD.

5/8" GYP. BD. ON 3 5/8"

MTL. STUDS

/8

/8

U

EXISTING CONCRETE COLUMN.

SEE STRUCT.

CORNER GUARD, TYP.

5/8" GYP. BD. ON 2 1/2"

MTL. STUDS

/2

/8

/8

11 1/2" 11 1/2"

1151 Kildaire Farm Rd.

Suite 120 Raleigh, NC 27511 www.acg-pa.com (919)858-7420

108 Benton Lodge Road Suite B Summerville, SC 29485 www.cemsengineering.com (843)875-3637Project Mgr: Alex Kramer (APOGEE)

Joint Venture An Alliance for Success

Revisions: Date

Drawing Title

Approved: Project Director

Project Title

Location

VA PROJECT NUMBER

Building Number

Drawing Number

Dwg of

VA FORM 08-6231

Office of Construction and Facilities Management

CONSULTANTS: PROJECT MANAGER

Date Checked Drawn

FULLY SPRINKLERED

ACG Project Number

U.S. Department of Veterans Affairs# © COPYRIGHT Apogee - CEMS JV, LLC

JOHN A. JURGIEL & ASSOCIATES, INC.

123 N. Main Street (636)757-3060 St. Charles, MO. 63301 Jurgiel.com

JURGIEL

JOHN A. JURGIEL & ASSOCIATES, INC.

/2

/2

:1

:3

P

M

A-501

PLAN DETAILS

12 14RR

RENOVATE SPACE FOR

WHOLE HEALTH

1 JEFFERSON BARRACKS DR.,

ST LOUIS, MO 63125

MAY 28, 2021

BID DOCUMENTS

657-20-101JB19-335

TJS

Scale: 1 1/2" = 1'-0"

ENLARGED PLAN…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .