3B.D(2024.11.13)USBR__Breakdown_of_space-3CA1541.xlsx

XLSX spreadsheet 34 KB Posted

Attached to
General Services Administration (GSA) seeks to lease office space in the Sacramento Metro Area
Solicitation number
3CA1541
Issued by

About this file

This document is a detailed breakdown of the required spaces and specifications for a federal office space lease opportunity in the Sacramento Metro Area. The General Services Administration (GSA) is seeking to lease approximately 32,046 usable square feet of office space to house the Central Valley Operations (CVO) facility, with a heavy focus on specialized technical spaces like a data center, communications tower room, control center, and secure information systems rooms. The space requirements include a variety of conference rooms, training rooms, hoteling/touchdown spaces, storage areas, and a full staff support area with break room, lockers, and showers. Key features include raised flooring, heavy load capacity, redundant power and HVAC systems, controlled access, and acoustic sound isolation for sensitive operations. The solicitation number is 3CA1541 and the opportunity is currently in the presolicitation phase.

View the file

Other files

File Type Posted
3F.6(2025.12.15)RLP Amend #6-3CA1541.pdf PDF
3F.5(2025.10.24)RLP Amend #5-3CA1541 (1).pdf PDF
3F.4(2025.09.12)RLP Amend #4-3CA1541.pdf PDF
3F.3-3B.Q(2025.05.30)Dual Agency Disclosure Form-3CA1541.pdf PDF
3F.3-3B.G(2025.05.30)3516 Solicitation Provisions (Feb. 2025)-3CA1541.pdf PDF
3F.3(2025.05.30)RLP Amendment #3-3CA1541.pdf PDF
3F.3-3B.H(2025.05.30)3517B General Clauses (Feb. 2025)-3CA1541.pdf PDF
3F.2(2025.04.03)RLP Amendment #2-3CA1541.pdf PDF
3F.1-3B.P(2025.02.21)ForOwnership&Fin. Rep. for High Sec. Leased Space-3CA1541.pdf PDF
3F.1(2025.02.21)RLP Amendment #1-3CA1541.pdf PDF
2A(2025.01.10)Rev Ad-3CA1541.pdf PDF
3B.L(2024.11.20)Seismic Forms (A-D) with Insturctions-3CA1541.pdf PDF
3B.I(2024.11.20)GSA Form 1364 (Jan. 2023) Open with Adobe Only-3CA1541.pdf PDF
3B.K(2024.11.20)FPLS Prelease Evaluation Form 12000-3CA1541.pdf PDF
3B.N(2024.11.20)NHPA Section106_Checklist-3CA1541.pdf PDF
3B.D(2024.11.20)USBR_Breakdown_of_space-3CA1541.pdf PDF
3B.J(2024.11.20)GSA From 1217 Lessor's Annual Cost Statement-3CA1541.pdf PDF
3B.B(2024.11.20)NOAA POR (11-06-2024)-3CA1541.pdf PDF
3B.M(2024.11.20)FAR 52.204-24 Representation (Nov. 2021)-3CA1541.pdf PDF
3B(2024.11.20)RLP-3CA1541.pdf PDF
3B.E(2024.11.20)Security Requirements (FSL Level III)MODIFIED-3CA1541.pdf PDF
3D(2024.11.20)Procurement Summary-3CA1541.pdf PDF
3B.F(2024.11.20)Security Requirements (FSL Level II)-3CA1541.pdf PDF
3B.C(2024.11.20)USBR_-_POR_24OCT11(FINAL)-3CA1541.pdf PDF
3B.H(2024.11.20)3517B General Clauses (Dec. 2023)-3CA1541.pdf PDF
3B.G(2024.11.20)Form 3516 Solicitation Provisions (Dec. 2023)-3CA1541.pdf PDF
3B.A(2024.11.20)Draft Lease-3CA1541.pdf PDF
2A(2024.09.19)4th SAM Presolicitation Notice-3CA1541.pdf PDF
2A(2024.07.18)3rd SAM Presolicitation Notice-3CA1541.pdf PDF
2A(2024.04.18)2nd SAM Presolicitation Notice-3CA1541.pdf PDF
3CA1541-SAM Presolicitation Notice-2024-00-01.pdf PDF
Show all 31

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Room Specification

IdentificationDescriptionMaterials / OpeningsBuilding SystemsFurniture/Equipment
Room TypeRoom CodeSpace NumberAssignable SF Area (Per)QuantityTotal SF AreaDate RevisedFunctionAdjacenciesOccupancy LoadMin. CLG. HT.Access / ServiceHours of OperationFloorBaseWallsCeilingDoors/FramesSpecial OpeningsWindowsLightingHVACPlumbingElectricalFire ProtectionSecurityCommunicationsAcousticsBuilt-In FeaturesFixed EquipmentA/V EquipmentMoveableSpecial RequirementsComments
Battery Room20012001/1/23CVO needs 200 sf, minimum storage for UPS batteries and to facilitate maintenance and ensure safety (10ft by 20ft room)UPS RoomWill require heavy loading for weight of batteries and racksAccess to this room shall be controlled by card reader linked to the CVO PACS with key bypass24/7Concrete, with acid resistant floor coatingPerimeter walls must be solid and true slab-to-slab. STC Rating of 45 required.Single header 16 gauge hollow steel doors and frame with a minimum opening of 64”.Recessed24/7 properly exchange air to exterior of building or meets building code requirements. Will require ventilation equipment, eye wash station, and floor installed liquid containment section. (Isolated HVAC)Requires circuit breaker panel. One duplex 110v receptacle needed for trickle charging spare batteries. Requires two Cat6 cables to Data Center.As allowed per codePotable water eye wash station with drain.Battery type to be specified during design phase
Calming Room14011401/1/23To facilitate lactation and relaxation activities.None. Optional -- May be included within the confines of the Staff Support Area.STC Rating of 45 required.Doors lockable from the inside.Dimmable lighting.Room shall have separate temperature controls.Dedicated circuit for small refrigerator with freezer. Dedicated circuit for microwave. Outlet located near wall mounted 43-inch monitor minimum. Floor mounted Cat6 (or better), visual (for wall-mounted monitor), and power outlets in the center floor of the room. Other outlets along perimeter wall per code.As allowed per codeAt least two network drops in the calming room.A single bowl stainless steel sink shall have hot and cold running water with high neck faucet and handle and separate taps to control water temperature. Room shall have a undercounter refrigerator and a wall mounted 1,100 watt (minimum) microwave. Upper and lower cabinets similar in style to the kitchen area with a minimum of six feet of counterspace. Wall for television should be reinforced to support the weight of the television.This room will have a wall-mounted monitor.
Communications Tower11/1/23Height dependent upon location.Communications Tower Data Room.As allowed per codegrounding, seismic considerations requiring special equip, zone consideration,Considerations: Line of site to Folsom Dam tower, tower or roof top antennas, OCIO directives 2009-008, motorola standards, EIA/TIA, ANSI and NFPA. Must be able to support Dish-style antennas.
Communications Tower Data Room12011201/1/23Dedicated external CVO room adjacent to the communications tower to facilitate communications. Concrete building.Communications towerRequire heavy loading designation. 250 lb/ft2 Floor LoadPhysical Key. Must have back boxes and conduit for potential PACS implementation at a future date.Ceiling mounted cable ladder racks (design approved by the government). Should be able to support at least two server racks. 300 pound live load.Independent HVAC needed to maintain humidity and temperature (68 to 72 degrees).UPS (3KVA) and non-UPS (7KVA) power sources.As allowed per codeAccess will be monitored by CVO’s PACS. Power and back boxes needed for cameras.Conduits to tower. A minimum of two (2) three-inch secured conduit runs to the Data Center and 0ne (1) three-inch secured conduit run to the Telecom Room for low-voltage communications. Radio Frequency shielding may be necessary. 2-inch conduit for power and two three-inch conduits for low-voltage to the base of the Communications Tower.
Data Center70017001/1/23Data Center for Central Valley Control Center.Critical Security Room. Control Center, ICSD Operations Room, Telecom Room, UPS RoomRequire heavy loading designation. 250 lb/ft2 Floor Load. See: https://www.gsa.gov/node/8243411ft minimumAccess to this room shall be controlled by card reader linked to the CVO PACS with key bypass24/7 continuous operationRaised floor with non-static vinyl composition tile (VCT) with cable management. Ceiling mounted cable ladder racks (design approved by the government).ResilientPainted gypsum board. STC Rating of 50 required. Perimeter walls must be solid and true slab-to-slab.Suspending acoustical ceiling, with recessed lightingDouble security door entry with a minimum opening of 64”. If this room does not share a ingress with the Control Center, then a double-door “sally port” will be required at the primary entrance into the room. This room must share a doorway with the ICSD Operations Room.Size and number of cable conduits reserved for future use between rooms shall be determined during Design Intent Drawings development. The size and number of conduit is directly dependent upon room location and layout. weather-proof head/roof access to satellite time receiver antenna, and UPS Room.NONERecessed, indirect, emergency lighting requiredRedundant, independent closed system, environmental controls for sensitive electronic equipment, conditioned air supplied under raised floor to equipment racks, fully redundant, designed for 24/7 continuous operation. Independent HVAC system is required to keep this room between 65 and 72 degrees Fahrenheit. Chilling equipment should be located directly outside of the data center so maintenance personnel do not need to access the data center space.Generator Backup Required. (UPS and PDU are part of a matched system), power cables and receptacles distributed under raised floor to equipment racks. This room will need to support 10 server racks with growth for an additional 4 racks (14 racks total). Each of the 10 racks shall have a minimum 7.2kW source from the CVO UPS and a minimum 7.2kW source from non-UPS (i.e., house) power. Power panel located inside the room to support house power requirements. The 4 racks for growth shall have sufficient conduit to the UPS room to allow for potential future power pull.NFPA 75 Standard for Protection of IT Equipment, FM 200, fire sprinklersCVO restricted access via HSPD-12 compliant access card key system, intrusion detection, CVO security camera. Power and back boxes needed for cameras at all access points.Communications cables and interconnecting cables under raised floor between equipment racks in CVO Data Center, ICSD Operations Room, Telecom Room, and Control Center, telephone jacks (12) to computer workstations/tables, signal cable from satellite time receiver antennaHeavy acoustic sound reductionDesign of environmental controls and emergency power must incorporate “no disruption of mission critical equipment or systems” criteria.
Conference Room Large1100111001/1/23CVO Conference Room / Staff Training Room (Customer Meetings are held here). Must have viewing capability into the Control Center. Sufficient for 65 personnel.Access to this room shall be controlled by card reader linked to the CVO PACS with key bypassLow profile carpetedWalls shall be rated with an STC of 45 for all Meeting Rooms.Floor or ceiling must accommodate necessary future electrical and AV cabling reconfiguration at minimum cost. Acoustical Ceiling tilesRequires 48” minimum width door. Multiple egress doors.Recessed, indirect, dimmingLarge duct runs with dedicated thermostat control to accommodate 60-80 attendees. Dedicated Zone.Room requires multiple floor mounted data and power receptacles at locations to be approved by the government.

Lessor shall supply and install one tilting/swiveling flat screen monitor mount capable of supporting a 100lb monitor in each room section. Height and location for all monitor related items to be approved by the government. Lessor shall install government supplied monitors.

One floor mounted audio-visual cable and one Cat6 cable (minimum) shall run to the location of flat screen monitor mount from the center of each respective room section. Type of cable and location to be approved by the government. Each room section shall have at least two Cat-6A cables to the ISCD Telecom Room. Monitor mount location requires a duplex outlet.As allowed per codeIntent of this room is to facilitate teleconferencing capabilities. Design and location of data and power recepticles should be condusive to the intent of this room. Design considerations should also account for the government's ability to readily replace audio-visual cables as needed due to technology changes.Heavy acoustical sound reductionWhite boards as determined by government.Powered projection screen approximately 60” high and 96” wide (installation location subject to government approval).Designed to accommodate various AV devices for slide, power point, tv, and other presentations. Wall mounted television.Ability to access electrical and AV conductors and cables with minimum disturbance to floor, walls, or ceiling.This room should be designed to be segmented into 3 separate small conference rooms by utilizing sliding partitions. The partitions should be heavy duty soundproof and capable of being hidden in wall cabinets.
Conference Room Medium60016001/1/23Video Conference RoomPrefer to be adjacent to the Control Center.Access to this room shall be controlled by card reader linked to the CVO PACS with key bypass.Low profile carpetedWalls shall be rated with an STC of 45 for all Meeting Rooms.Requires dropped ceiling to accommodate necessary electrical and AV cablingWill require double-door entry with minimum opening of 64” to accommodate installation of conference table and AV equipmentSolid pane viewing areas into adjacent Control Center. Windows shall be approximately 3ft high and 8 ft long at a height to be approved by the Government. Glass shall be no less than 5/16” and laminated security glass (meeting ASTM F1233 Forced Entry Test, Class 2).Recessed, indirect, dimmingLarge duct runs to account for numerous attendeesRoom requires multiple floor mounted data and power at locations to be approved by the government during the design phase. Room requires ceiling mounted duplex receptacle and data for wireless access point.

Lessor shall supply and install one tilting/swiveling flat screen monitor mount capable of supporting a 100lb monitor. Height and location for all monitor related items to be approved by the government. Lessor shall install government-supplied monitor.

One floor mounted audio-visual cable and one CAT-6A cable shall run to the location of flat screen monitor mount. Type of audio visual cable and location to be approved by the government. Monitor mount location requires a duplex outlet.As allowed per codeIntent of this room is to facilitate teleconferencing capabilities. Design and location of data and power recepticles should be condusive to the intent of this room. Design considerations should also account for the government's ability to readily replace audio-visual cables as needed due to technology changes.Heavy acoustical sound reductionWhite board, drop screenShall be equipped with a flush ceiling mounted, powered projection screen approximately 60” high and 96” wide (to be installed at a location approved by the government).Ability to access within room audio-visual cables to monitor with minimum disturbance to floor, walls, or ceilingConference table and chairs to accommodate 30 CVO attendees.
Emergency Operations Conference Room w/Restroom1200112001/1/23Video Conference RoomOff of the Reception Area. Requires included non-gender-specific restroom.Access to this room shall be controlled by card reader linked to the CVO PACS with key bypass.Emergency 24/7, normally 7:00 AM-5:00 PMLow profile carpetedWalls shall be rated with an STC of 45 for all Meeting Rooms.Requires dropped ceiling to accommodate necessary electrical and AV cablingWill require double-door entry off of Reception Area with minimum opening of 64” to accommodate installation of conference table and AV equipmentRecessed, indirect, dimmingLarge duct runs to account for numerous attendeesRoom requires multiple floor mounted data and power at locations to be approved by the government during the design phase. Room requires ceiling mounted duplex receptacle and data to the ICSD Telecom Room for wireless access point.

Lessor shall supply and install three tilting/swiveling flat screen monitor mounts capable of supporting a 100lb monitor each. Height and location for all monitor related items to be approved by the government. Lessor shall install government-supplied monitors.

Floor mounted audio-visual cables and one CAT-6A cables shall run to the locations of flat screen monitor mounts. Type of audio visual cables and locations to be approved by the government. Monitor mount locations require a duplex outlet. Lessor shall install one co-axial cable and one CAT-6A (MINIMUM) jack to the ICSD Operations Room.As allowed per codeIntent of this room is to facilitate teleconferencing capabilities adn to function as an emergency management room when needed. Design and location of data and power recepticles should be condusive to the intent of this room. Design considerations should also account for the government's ability to readily replace audio-visual cables as needed due to technology changes.Heavy acoustical sound reductionWhite board, drop screen. Requires approximately 10 linear feet of counter space with storage cabinets above and below. Cabinet and countertop materials and design to be approved by the Government. One double bowl stainless steel sink (approximately 21” x 33”), with hot/cold water to be installed in countertop). 4 GFCI protected duplex receptacals above countertop for small appliance use.Ability to access electrical and AV conductors and cables with minimum disturbance to floor, walls, or ceilingHigher than normal electricity requirements.
Conference Room Small12033601/1/23Small conference rooms spread throughout the CVO office workspace, are needed to provide quiet rooms for client meetings, reviews, confidential discussions and conference calls.Normally 7:00 AM- 5:00 PMLow profile carpetedWalls shall be rated with an STC of 45 for all Meeting Rooms.Minimum 36” doors with key locks to accommodate installation of small conference tables.Recessed, indirectRoom requires floor mounted data and power at locations to be approved by the government during the design phase (typically in the center of the room). Room requires ceiling mounted duplex receptacle and data for wireless access point.

Lessor shall supply and install one tilting/swiveling flat screen monitor mount capable of supporting a 100lb monitor. Height and location for all monitor related items to be approved by the government. Lessor shall install government-supplied monitor.

One floor mounted audio-visual cable and one CAT-6A cable shall run to the location of monitor mount. Type of audio visual cable and location to be approved by the government. Monitor mount location requires a duplex outlet.As allowed per codeIntent of this room is to facilitate teleconferencing capabilities. Design and location of data and power recepticles should be condusive to the intent of this room. Design considerations should also account for the government's ability to readily replace audio-visual cables as needed due to technology changes.Heavy noise reduction acoustics for privacyOne wall mounted VESA mount for a 60 pound (minimum) monitor next to the wall mounted CAT-6A, HDMI back box, and power outlet.Wall mounted television.
Control Center2,400124001/1/23CVO Hydro System Control Center.Critical Security Room. Should be near the Staff Support Area. Office HSC Lead should be directly attached to this room. Should be near the Data Center.Heavy loading of 250lb/sf. Raised floor with cable management.14 ftAccess to this room shall be controlled by card reader linked to the CVO PACS with key bypass24/7 continuous operationRaised floor with non-static, acoustic tile, surfaceResilientPainted Gypsum Board. STC Rating of 50 required. Perimeter walls must be solid and true slab-to-slab.Raised ceiling to accommodate tall monitoring equipmentDouble door entry. 16 gauge hollow steel doors and frame with a minimum opening of 64”. "Sally Port" door entry system.Size and number of cable conduits reserved for future use between rooms shall be determined during Design Intent Drawings development. The size and number of conduit is directly dependent upon room location and layout. Weather-proof head/roof access for satellite phone antenna cable.Suspended indirect with Recessed direct, Individual Controller Console task lighting, emergency lighting24/7 Redundant CapabilityOutlets providing power for Government-identified critical equipment shall be connected to redundant UPS system. Other systems shall be powered by conditioned non-UPS source. Power cables and receptacles distributed under raised floor to controller consoles. Adequate Floor box spacing and quantity to allow for future changes (all above to be determined during design).FM 200, fire sprinklersCritical Security Room. CVO restricted access via HSPD-12 compliant access card key system. In addition, slab-to-slab partition shall have 3/8” fire-resistant plywood affixed to studs with #10 self tapping screws every 12” on the secure side of this room. Power and back boxes needed for cameras at all access points.Communications cables and interconnecting cables in conduit under raised floor between 4 controller workareas, central control display panels, Data Center, Telecom Room, Telephone jacks to controller consoles and fax machine, Cable TV to central control display panels, CVO closed circuit camera system, signal cables to CVO Satellite phone antenna, VHF radio. Eight CAT-6A (MINIMUM) data outlets per desk. Display wall requirements need to support several large monitors.Heavy acoustic sound reductionMust include a kitchenet area (Full size refridgerator, undercabinet microwave). Sufficient power to also handle a coffee maker and toaster. Must include a sink with a garbage disposal and 10 feet of counterspace with upper and lower cabinets.Display wall minimally consists of 3 60in monitors and 4 45in monitors and a single 36in monitor and a time clock. Need video and data conduits between desks and each monitor. Other monitors may be added as needed. Power to all monitor locations. Display wall is offset from the room's perimeter wall by two feet to allow mounting, replacement, and maintenance of equipment and cabling.See Fixed EquipmentFour large controller workareas, facing a large control display panel. Must adhere to WECC and NERC standards for control Center design and function.
Control Center Training Room45014501/1/23CVO Hydro System Controller’s Training Room.Outside of the Critical Security Room area. but near Control Center.11 ftAccess to this room shall be controlled by card reader linked to the CVO PACS with key bypass.Low profile carpeted raised floor with built in cable management.Suspended acoustical ceilingDouble door entry. 16 gauge hollow steel doors and frame with a minimum opening of 64”. "Sally Port" door entry system.Recessed LightingNeeds separate controls for HVAC settingsDimming lights, power cables and surge-protected power strips to training workstations. Power and a duplex CAT-6A (MINIMUM) outlet to be installed by lessor in the ceiling (to facilitate wireless access point installation by Government).As allowed per codeCommunications cables and interconnecting cables between ten computer workstations classroom type setup, LCD projector and instructor workstation, and Data Center, Telecom Room, Telephone. 6 power outlets (2 isolated ground for computers), two CAT-6A (MINIMUM) cables and one telephone cable per workstation.White board, powered drop screenSix to ten training workstations, computer training design, classroom type setup. Two separate network cables for each workstation.LCD projector, ceiling mount. Power and duplex CAT-6A (MINIMUM) outlet to be installed by lessor at the location of the projector
Copy and Plotter Room20012001/1/23Independent. For copy and reproduction services. Space requirements for: Copy machine, shredder, plotter, work table, digital sending machine, white paper recycle bins, etc.Near Workstation AreaLow profile carpetedPainted gypsum board. (Walls shall be rated with an STC of 45)Minimum of Two 115 volt/20 amp dedicated power outlets for copy machines are required. Four 115 volt, 15 amp power outlets.As allowed per codeNetworks drops for business LAN use. Five duplex CAT-6A (MINIMUM) outlets are required for copier/fax function. The telephone lines shall be single dedicated dial up lines.Approximately 12 linear feet of storage cabinets with laminated work top shall be installed. Counter height shall not exceed 34”.Millwork required to provide for mail sorting area.
Hoteling Workspace30013001/1/23Space to house 6 hoteling workspacesNear Workstation AreaLow profile carpeted6 two duplex power recepticles spaces under desks with two adjacent data outlets per desk.As allowed per code
ICSD Operations Room1800118001/1/23Information system development and testing laboratory.Critical Security Room. Directly off the Data Center.Heavy loading capability to support large equipment. 250 lb/ft Floor Load11 ftAll access points to this room shall be controlled by card reader linked to the CVO PACS with key bypass24/7Raised floor, reinforced for loading & static resistant surface. Cable management within floor and dropped from ceiling. Ceiling mounted cable ladder racks (design approved by the government).Perimeter walls must be solid and true slab-to-slab. STC Rating of 45 required.Double door entry. 16 gauge hollow steel doors and frame with a minimum opening of 64”.Antenna cabling access, weather head/roof accessRecessed, emergency lightingNeeds separate controls for HVAC settings.Eight four-plex 120 volt, 20-amp power outlets shall be connected to redundant UPS system (this room will have some critical equipment). 12 four-plex 120 volt, 20-amp conditioned house powered outlets. Power cables and receptacles distributed under raised floor to controller consoles. Adequate Floor box spacing and quantity to allow for future changes (all above to be determined during design). This room will have 6 server racks distributed strategically throughout the room with 6KVA per rack power provided by a non-UPS source.NFPA 75 Standard for Protection of IT Equipment, FM 200, fire sprinklersCritical Security Room. Power and back boxes needed for cameras at all access points.Size and number of cable conduits reserved for future use between rooms shall be determined during Design Intent Drawings development. The size and number of conduit is directly dependent upon room location and layout.Heavy acoustic sound reductionInformation Technology/Server racks will be required. Rack-mounted UPSs will be used.
ICSD Maintenance Garage (Technical Area with Vehicle Storage)80018001/1/23Maintenance of Mission Critical Electronic Equipment and Systems. One vehicle bay with roll-up door.Some heavy equipment may require heavy floor load capability of 250lb/sf12 ft MinimumAccess to this room shall be controlled by card reader linked to the CVO PACS with key bypass. Minimum 12' wide x 10' high roll-up door shall be physical keyed.Concrete floor.Painted gypsum board. STC rating of 50 required. Perimeter walls must be solid and true slab-to-slabSuspended acoustic tileOne (1) access point shall be16 gauge hollow steel doors to the interior of the building and roll-up door to the exterior of the building secured by CVO PACS.Dual access required for occupancySeparate controls for HVAC settings. Standard HVAC. External exhaust ventilation hood with fan required for soldering.Clean-up area, with deep sink and hot/cold water. Center floor drain. Requires approximately 10 linear feet of counter space with storage cabinets above and below. Cabinet and countertop materials and design to be approved by the Government. One single bowl stainless steel sink (approximately 21” x 33”), with hot/cold water and garbage disposal, to be installed in countertop)One 50-amp, 240 V receptacle. Multiple 120 V receptacles every six (6) ft., Earth-bonded ground for electrostatic discharge workbenches.As allowed per codeTelephone, VHF radio, interconnecting cables for computer workstation. 4 CAT-6A (MINIMUM) outlets.Noise IsolationEye wash stationOne Electronics ESD-rated work bench with built-in power and lighting. Two (2) equipment storage racks 10 ft long by 3 ft deep by 8ft high to be installed by the Government.
ICSD Telecom Room15011501/1/23CVO Dedicated Telecommunications Room for mission critical telecommunication equipment. Demarcation room.Critical Security Room. Near Data Center10 ft MinimumAccess to this room shall be controlled by card reader linked to the CVO PACS with key bypass24/7Sealed concrete, static free environment. Ceiling mounted cable ladder racks (design approved by the government).ResilientPainted gypsum board. One ¾ inch thick, wall mounted 8ft x 4ft fire rated plywood boards is required. Location of boards to be determined during DID development. Perimeter walls must be solid and true slab-to-slab. STC Rating of 45 required.Exposed structureMinimum 36” steel door and frame.Cable conduits between CVO Telecom Room, ICSD Operations Room, Data Center, Control Center.NONESuspendedRequired, for sensitive electronic equipment. Independent closed system, environmental controls for sensitive electronic equipment, conditioned air supplied, designed for 24/7 continuous operation. Independent HVAC system is required to keep this room between 65 and 72 degrees Fahrenheit. The HVAC can be tied to Data Center HVAC if adjacent. (Should run on a 24/7 basis)Shall have two equipment racks each powered by UPS and non-UPS power (3KVA UPS and 6KVA non-UPS per rack).NFPA 75 Standard for Protection of IT Equipment, FM 200, fire sprinklersCritical Security Room. Power and back boxes needed for cameras at all access points.Size and number of cable conduits reserved for future use between rooms shall be determined during Design Intent Drawings development. The size and number of conduit is directly dependent upon room location and layout.Requires approximately (change length as needed) 6 linear feet of counter space with storage cabinets above and below. Cabinet and countertop materials and design to be approved by the Government.Large equipment racks will be required.This room is separate from the shared main telecom facility entrance room (if exists). Three (minimum) 3-inch rigid conduit runs between the shared telecom facility entrance room and the Government’s Telecom room.
Loading Area (Delivery Receipt Area)20012001/1/23Receipt of goods.10 ft minimumMinimum 10' wide x 10' high roll-up door.As allowed per code
Office HSC Lead12011201/1/23Critical Security Room. Directly off the Control Center.Access to this room shall be controlled by physical key.Low profile carpetedTextured Sheetrock

STC rating of 50 is required for all Private Offices. Floor to Ceiling wall acceptable.

At least one wall shall have a window facing the Control Center's display wall.Duplex outlets within six feet of any wall location (12’ separation). One additional in the floor (under desk).As allowed per codeCritical Security Room.Four CAT-6A (MINIMUM) outlets.
Office Manager15057501/1/23Manager OfficesAccess to this room shall be controlled by physical key.Low profile carpetedTextured Sheetrock

STC rating of 50 is required for all Private Offices. One window preferred. Floor to Ceiling wall acceptable.

One designated wall will support a monitor (monitor mount, A/V cable, and power).Duplex outlets within six feet of any wall location (12’ separation). Lessor shall supply and install one tilting/swiveling flat screen monitor mount capable of supporting a 100lb monitor. Height and location for all monitor related items to be approved by the government. Lessor shall install government-supplied monitor. One floor mounted audio-visual cable and one CAT-6A cable shall run to the location of monitor mount. Type of audio visual cable and location to be approved by the government. Monitor mount location requires a duplex outlet.As allowed per codeFour CAT-6A (MINIMUM) outlets.40 inch wall mounted monitor with power. Video and data cabling to desk area.
Office Supervisor12067201/1/23Supervisor Offices located strategically throughout spaceAccess to this room shall be controlled by physical key.Low profile carpetedTextured Sheetrock

STC rating of 50 is required for all Private Offices. Floor to Ceiling wall acceptable.

One window perferred. One designated wall will support a monitor (monitor mount, A/V cable, and power).Duplex outlets within six feet of any wall location (12’ separation). One additional in the floor (under desk location). Lessor shall supply and install one tilting/swiveling flat screen monitor mount capable of supporting a 100lb monitor. Height and location for all monitor related items to be approved by the government. Lessor shall install government-supplied monitor. One floor mounted audio-visual cable and one CAT-6A cable shall run to the location of monitor mount. Type of audio visual cable and location to be approved by the government. Monitor mount location requires a duplex outlet.As allowed per codeFour CAT-6A (MINIMUM) outlets.
Secured Reception Area30013001/1/23The Reception Area room is a controlled access room for visitors and shall be divided into a general reception area and a secure staff work section. Access to the staff work section shall be provided from the interior Government space only not including the Reception Area space.Access to the government reception area space shall be controlled using a CVO PACS to unlock the double door leading into the space government. Lessor shall install Visitor Access Control (VAC) ‘buzzer buttons’ located within the staff work area giving government staff the ability to remotely unlock the external-facing perimeter door and the door leading into other government internal spaces from the Reception Area, including the Emergency Operations Conference Room w/Restroom. The doorway to the government interior space from the Reception Area shall also be controlled by CVO PACS.Floor covering shall be stone, stone tile, porcelain tile or other solid surface to be approved by the government.Walls between the general reception area and the secure staff work section and the rest of the interior government space shall be slab-to-slab using standard building wall partition materials. In addition, slab-to-slab partition shall have 3/8” fire-resistant plywood affixed to studs with #10 self tapping screws every 12” on the secure side of secure staff work section.All double doors.Shall have four duplex 120 volt, 15 amp power outlets and Six CAT-6A (MINIMUM) duplex data outlets. Lessor shall supply and install one tilting/swiveling flat screen monitor mount capable of supporting a 100lb monitor. Height and location for all monitor related items to be approved by the government. Lessor shall install government-supplied monitor. Monitor mount location wil require duplex power receptacle. Monitor mount location will require a data cable ran to ICSD Telecom Room and one coax cable ran to the ICSD Operations room. Monitor mount location requires a duplex outlet.As allowed per codePower and back boxes needed for cameras at all access points.One wall between the General Reception Area and secure staff work area shall house a Reception Counter, consisting of clear glass and a transaction counter. The glass shall be no less than 5/16” laminated security glass (meeting ASTM F1233 Forced Entry Test, Class 2) with a sliding lockable glass door design. Minimum opening for the sliding glass door area is 18” wide. The total glass area shall be a minimum of 60” wide and 42” high. Glass shall be mounted in a stainless steel frame with a granite transaction counter along the full length of the window area. Counter width shall be between 15” and 24”. Millwork allowing up to two staff to work within the interior Government space shall be installed by the Lessor as part of the Reception Counter design. Design and materials shall be approved by the government.Location of doors, buzzers, reception window, etc., to be determined by the government during Design Intent Drawings development.
Staff Support Area1400114001/1/23Dedicated to CVO personnel. Includes spaces for a full kitchen/break-room area, male and female restrooms, male and female locker rooms, janitorial water closet, male and female shower rooms..Outside of but near Control Center.
24/7Accessible doors where required.24/7Ceramic tile shower room area. Resilient tile with anti-microbial agent in other areas.Perimeter walls must be solid and true slab-to-slab. STC Rating of 45 required.Outside venting for stove/oven hood.Sufficient power for two full-sized refrigerators, two microwave ovens, two coffee makers, one electric range/oven (with ventilation hood), and other small appliances. A soap dispenser, paper towel dispenser, and instant hot water shall be provided. The kitchen area shall include a countertop area that includes a stainless steel double-bowl sink with a garbage disposal, soap dispenser, paper towel dispenser, and hot and cold running water. Instant hot water shall be provided. CVO will install a 60 inch television in the kitchen area, which will require data, coax, and electrical.As allowed per codeNetworks drops available in the break room area. Televsion-cable coax cable installed to Information Technology Development and Test Lab area.Millwork - Kitchen area requires approximately 15 linear feet of counter space with storage cabinets above and below. Cabinet and countertop materials and design to be approved by the Government. Automatic paper towel dispenser. Janitorial closet shall include a map basin sink with hot and cold water and room for storage of janitorial supplies. Wall for 60" television should be reinforced to support the weight of the television.Wall mounted television.
Storage Room Admin Division30013001/1/23CVO Equipment Storage Room (Equipment rotates every 3 years)Requires additional floor loading capacity to accommodate heavy items, densely packed. 250 lb/ft floor load?Minimum 10 ftAccess to this room shall be controlled by card reader linked to the CVO PACS with key bypassSealed concreteResilientPainted gypsum board.Exposed structureDouble door entry. 16 gauge hollow steel doors and frame with a minimum opening of 64”.NoneRecessed, where practical, emergency lightingStandard (sensitive electronic equipment stored in this room)Standard 120VAC outlets every 8 ft on wallsAs allowed per codePhone. Two CAT-6A (MINIMUM) data outlets for future use.Will require heavy duty loading racks or shelving, specifications to be provided at a later time.
Storage Room ICSD60016001/1/23CVO Equipment Storage Room (Equipment rotates every 3 years)Requires additional floor loading capacity to accommodate heavy items, densely packed. 250 lb/ft floor load?Minimum 10 ftAccess to this room shall be controlled by card reader linked to the CVO PACS with key bypassSealed concreteResilientPainted gypsum board.Exposed structureDouble door entry. 16 gauge hollow steel doors and frame with a minimum opening of 64”.NoneRecessed, where practical, emergency lightingStandard (sensitive electronic equipment stored in this room)Standard 120VAC outlets every 8 ft on wallsAs allowed per codePhone. Two CAT-6A (MINIMUM) data outlets for future use.Will require heavy duty loading racks or shelving, specifications to be provided at a later time.
Storage Room Power Division20012001/1/23CVO Equipment Storage Room (Equipment rotates every 3 years)Requires additional floor loading capacity to accommodate heavy items, densely packed. 250 lb/ft floor load?Minimum 10 ftAccess to this room shall be controlled by card reader linked to the CVO PACS with key bypassSealed concreteResilientPainted gypsum board.Exposed structureDouble door entry. 16 gauge hollow steel doors and frame with a minimum opening of 64”.NoneRecessed, where practical, emergency lightingStandard (sensitive electronic equipment stored in this room)Standard 120VAC outlets every 8 ft on wallsAs allowed per codePhone. Two CAT-6A (MINIMUM) data outlets for future use.Will require heavy duty loading racks or shelving, specifications to be provided at a later time.
Supply Room15011501/1/23General Supplies. Access to this room shall be controlled by card reader linked to the CVO PACS with key bypass.Access to this room shall be controlled by physical key.Resilient tile, 250 live load minimumResilientPainted gypsum boardExposed structureMinimum 36” double-door entry with keyed lock. Double doors to allow access for pallets.SuspendedAs allowed per codeStandard 36” wide Shelving.
Technical Library and High Density File Room60016001/1/23Technical Library for CVO Project Files, Reference Materials, and Compliance Documentation.Will require heavy loading capability to accommodate large condensed moveable file cabinets. 250 lb/ft floor load minimumRequires dropped ceiling to accommodate electrical for moveable filesAccess to this room shall be controlled by physical key.Normally 7:00 AM-5:00 PMResilient tileResilientRequires 36” Security Door.Recessed lighting preferredAs allowed per codeMay require network drops w/adjacent power receptacle to be used for IP-based cameras to monitor all ingress and egress points. Four CAT-6A (MINIMUM) data outlets for future use.Will require a section to house very heavy, fireproof cabinets, with security locks, for storage of Restricted/Official Use Only documents.File cabinets will move mechanically to conserve space. (Herman Miller 2X Cabinets, Rolling Files)
UPS Room12011201/1/23Uninterrupted Power Supply Room to house UPS.Critical Security Room. Adjacent to Battery Room. Near Data Center, Telecom Room, and Control Center.Access to this room shall be controlled by card reader linked to the CVO PACS with key bypass24/7Concrete or equivalent, with non-skid & non-static surfacePerimeter walls must be solid and true slab-to-slab. STC Rating of 45 required.Double door entry. 16 gauge hollow steel doors and frame with a minimum opening of 64”.Recessed, emergency lighting requiredIndependent closed system, environmental controls for sensitive electronic equipment, conditioned air supplied, designed for 24/7 continuous operation. Independent HVAC system is required to keep this room between 65 and 72 degrees Fahrenheit.Requires power panel & breakerNFPA 75 Standard for Protection of IT Equipment, FM 200, fire sprinklersCritical Security Room. Power and back boxes needed for cameras at all access points.Communications cables and interconnecting cables to Data Center equipment monitoring UPS Room environmental condition, telephone.
Workstation Area648655043/8/23General cubicles (current FTE plus vacancies =83 (subtracting control room personnel 15)=71; (11 FTE for future reorgs?; 4 FTE for EMP staff)Low profile carpeted.Standard duplex outlet plus one UPS. Two data outlets minimum per workstation.

Perimeter Walls around Workstations:

Two duplex 120 volt, 20 amp power outlet shall be installed along perimeter walls every 12 linear feet.

The Lessor shall provide as part of the TIs separate CAT-6A (MINIMUM) In all open work areas data, telephone, and electric junction boxes for the base feed connections to Government provided modular or systems furniture, when such feeds are supplied via wall outlets or floor penetrations. Raceways shall be provided throughout the furniture panels to distribute the electrical, telephone, and data cable. The Lessor shall provide all electrical service wiring and connections to the furniture at designated junction points. Each electrical junction shall contain an 8 wire feed consisting of 3 general purpose 120 V circuits with 1 neutral and 1 ground wire, and a 120 V isolated ground circuit with 1 neutral and 1 isolated ground wire. A 20 ampere circuit shall have no more than 8 general purpose receptacles or 4 isolated ground "computer" receptacles.As allowed per codeHeavy acoustical sound reduction
Outside Hazardous Storage12011203/29/24A potable water hose bib and an eye station must be located within 1 foot
of the storage unit’s foundation or attached directly to the storage unit.As allowed per code
Outdoor Break AreaOutdoor space to allow employees to take breaks outdoors, including eating lunch, maybe BBQ?
Total21604
Net Usable Square Footage (NSF)21,364Total less Tower Data Room and Outside Hazardous Storage (21348 -240)
Circulation Multiplier1.50
Usable Square Footage (USF)32,046NSF x CM
Circulation Area10,682USF - NSF
Circulation Factor33.3%Circulation Area / USF

Space

RoomSqFtHeavy LoadingGround FloorUpdated Raised Floor14' Ceiling Height11' Ceiling HeightDuring Workhours Recarpeting and Painting
Battery Room200200200
Calming Room140
Communications Tower0
Communications Tower Data Room120
Data Center700700700700700
Conference Room Large1100
Conference Room Medium600
Emergency Operations Conference Room w/Restroom1200
Conference Room Small360
Control Center2400240024002400
Control Center Training Room450450450
Copy and Plotter Room200
Hoteling Workspace300
ICSD Operations Room18001800180018001800
ICSD Maintenance Garage (Technical Area with Vehicle Storage)800800800
ICSD Telecom Room150150150
Loading Area (Delivery Receipt Area)200200
Office HSC Lead120
Office Manager750
Office Supervisor720
Secured Reception Area300
Staff Support Area1400
Storage Room Admin Division300300300
Storage Room ICSD600600600
Storage Room Power Division200200200
Supply Room150
Technical Library and High Density File Room600600600600
UPS Room120120120
Workstation Area5504
Outside Hazardous Storage120
Outdoor Break Area0
787027005350240029503570
Assigned USF (CM = 1.50)787040508025240029503570
No CMNo CMNo CM
Heavy Loading Ground Floor2500

File details come from the government source that posted it. Updated .