37-IFB-26-00287 Plans - SIGNALIZATION.pdf
PDF 9 MB Posted
- Solicitation number
- IFB-26-00287
- Issued by
- Hillsborough County, Florida
About this file
This is a signalization plans document prepared by Element Engineering Group, LLC for Hillsborough County Public Works Administration related to CIP Project 69600318, which involves intersection improvements at CR 584 (Waters Avenue) at Florida Mining Boulevard in Tampa, Florida. The project includes comprehensive signalization infrastructure, signing, and pavement marking improvements at this intersection. The plans encompass multiple components including traffic signal installation, pedestrian signals with countdown timers, vehicle detection systems using microwave radar technology, fiber optic communication lines, signal controller cabinets, mast arm assemblies, conduit and pull box systems, and associated electrical service infrastructure. The project requires installation of numerous sign assemblies, pavement markings including thermoplastic and painted applications, raised pavement markers, and guide signs. Specific quantities include 8 vehicular traffic signal assemblies with varying section configurations, 8 pedestrian signal assemblies with LED countdown displays, 2 steel mast arm assemblies, multiple signal poles and pedestrian signal pedestals, approximately 1,195 linear feet of conduit, 925 linear feet of fiber optic cable for underground installation, and various signing and pavement marking items across multiple plan sheets.
The plans are digitally signed and sealed by Vicken Serpekian, P.E., P.T.O.E. (License No. 82646) and prepared under Rule 61G15-23.004, F.A.C. The project is coordinated with Hillsborough County Traffic Operations and Engineering Sections, with specific contact requirements for notification prior to signal activation, loop cutting, and traffic management during construction. The plans incorporate microwave detection systems capable of detecting vehicle presence up to 140 feet with multi-beam radar technology suitable for multi-lane coverage. The signal timing plan utilizes a Signal Operation Plan (SOP) of 7 with specific movement configurations for the major street (CR 584 with movements 1, 2, 5, 6) and minor street (Florida Mining Boulevard with movements 4, 8, 8R). The project includes provisions for power outage emergency beacon operation with solar panel backup systems for emergency flasher operation. Contractor requirements include maintaining Florida electrical contractor's license, coordinating with utility companies for underground cable location and relocation, and compliance with Sunshine 811 statutes for utility identification.
View the file
Other files
Show all 44
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
N
12:06:46 PM P:\HCE1701\31-Waters at Florida Mining\CADD\69679026\signals\keyssg01.dgnvserpekian 8/28/2025
N .T .S
U .S
U .S
I-
S.R. 674
S.R. 60
S .R
U .S
I-
R a c e
Tr a c K
R d
Ehrlich Rd
D a le
M b r y
H w y
Hillsborough Ave.
S.R. 580
SHEET NO.
ENGINEER OF RECORD:
P.E. NO.:
CHANGED DUE TO REPRODUCTION.
NOTE: THE SCALE OF THESE PLANS MAY HAVE
SHEET DESCRIPTION
LOCATION OF PROJECT
82646
SIGNALIZATION PLANS
VICKEN SERPEKIAN, P.E., P.T.O.E
INDEX OF SIGNALIZATION PLANS
T
E
O F
F I
C I
A L
R
C O
D
T
I
S
E E
T
E C
T R
O N
C
G I
T A
L
Y
G N
A L
U
D
L E
G
A
C
COUNTY C.I.P. PROJECT MANAGER: MANUEL SANTOS, E.I.
69600318 26 T-1
CIP NO.
FISCAL
YEAR
SHEET
NO.
STATE OF
No 82646
R E
E
NI
G
NE LANOI
S S
E
F O
R P
ESNECI
L
A
DIROL
F
N
AI
KEPRES NEK
CI
V https://goo.gl/maps/BwKoVN3qfFSoocJV8
T-1 KEY SHEET
T-2 - T-3 TABULATION OF QUANTITIES
T-4 GENERAL NOTES
T-5 - T-8 SIGNING AND PAVEMENT MARKING PLAN
T-9 - T-10 SIGNALIZATION PLAN
T-11 SIGNAL COMMUNICATION PLAN
T-12 - T-13 GUIDE SIGN WORKSHEET
T-14 - T-17 SIGNALIZATION CROSS SECTION
T-18 - T-19 PEDESTRIAN SIGNAL DETAILS
T-20 MAST ARM TABULATION
T-21 MAST ARM SCHDUELE
T-22 - T-23 SPREAD FOOTER DETAILS
T-24 - T-27 SPLICING DETAIL
* ESD-1 ELECTRIC SERVICE DETAIL
CONTRACT PLANS
CIP # 69600318
CR 584 (WATERS AVENUE)
AT FLORIDA MINING BLVD. INTERSECTION IMPROVEMENTS
THE BOARD OF COUNTY COMMISSIONERS
PLANS PREPARED BY:
COMMISSIONERJOSHUA WOSTAL
COMMISSIONERHARRY COHEN
COMMISSIONERDONNA CAMERON CEPEDA
COMMISSIONERCHRIS BOLES
CHAPLAINGWENDOLYN "GWEN" MYERS
VICE-CHAIRCHRISTINE MILLER
CHAIRKEN HAGAN
HILLSBOROUGH COUNTY
PUBLIC WORKS ADMINISTRATION
(813) 386-2101
TAMPA, FL 33605
1713 E. 9th AVENUE
ELEMENT ENGINEERING GROUP, LLC
ON ANY ELECTRONIC COPIES.
SIGNATURE MUST BE VERIFIED
ON THE DATE ADJACENT TO THE SEAL
SIGNED AND SEALED BY:
THIS ITEM HAS BEEN DIGITALLY
The ESD-1 sheet is contained in a separate scanned document.
only to indicate that they are part of the Signalization Plans.
* These sheets are included in the Index of Signalization Plans
S C
A L https://goo.gl/maps/BwKoVN3qfFSoocJV8
8/28/2025vserpekian P:\HCE1701\31-Waters at Florida Mining\CADD\69679026\signals\TABQSG01.dgn12:06:53 PM
CIP NO. SHT. NO.
DESCRIPTION
REVISIONS
DATE DESCRIPTION
T
F I
C I
C O
E E
T
E C
T R
O N
G I
T A
L
G N
A L
D
L E
G
A
696003181713 E. 9th AVENUE
TAMPA, FL 33605
ELEMENT ENGINEERING GROUP, LLC
P.E. LICENSE NUMBER 82646
VICKEN SERPEKIAN, P.E., P.T.O.E.
T-2
TABULATION OF QUANTITIES
TABULATION OF SIGNING AND PAVEMENT MARKING QUANTITIES
NO.
ITEM
PAY
DESCRIPTION UNIT
SHEET NUMBERS
SHEET
THIS
TOTAL
TOTAL
GRAND
T-5 T-6 T-7 T-8
PLAN FINAL PLAN FINAL PLAN FINAL PLAN FINAL PLAN FINAL PLAN FINAL PLAN FINAL PLAN FINAL PLAN FINAL
700-1-111 SINGLE COLUMN GROUND SIGN ASSEMBLY, F&I GROUND MOUNT, LESS THAN 12 SF EA 2 3 5 5
700-1-112 SINGLE COLUMN GROUND SIGN ASSEMBLY, F&I GROUND MOUNT, 12.0-20.0 SF EA 3 3 3
700-1-113 SINGLE COLUMN GROUND SIGN ASSEMBLY, F&I GROUND MOUNT, 20.1-30.0 SF EA 1 1 1
700-1-500 SINGLE COLUMN GROUND SIGN ASSEMBLY, RELOCATE EA 1 2 3 3
700-1-600 SINGLE COLUMN GROUND SIGN ASSEMBLY, REMOVE EA 4 3 2 9 9
700-13-15 RETROREFLECTIVE SIGN STRIP- FURNISH AND INSTALL, 5' EA 1 1 1
704-1-4 TUBULAR MARKER, 36" YELLOW POST EA 6 6 6
705-10-1 OBJECT MARKER, TYPE 1 EA 2 2 2
706-1-3 RAISED PAVEMENT MARKER, TYPE B EA 181 181
(B/B) EA 1 1
(MD/Y) EA 21 38
(Y/Y) EA 34 4
(W/R) EA 7 69 6
710-11-290 PAINTED PAVEMENT MARKINGS, STANDARD, YELLOW, ISLAND NOSE SF 33 75 108 108
711-11-124 THERMOPLASTIC, STANDARD, WHITE, SOLID, 18" FOR DIAGONALS AND CHEVRONS LF 6 96 2 104 104
711-11-125 THERMOPLASTIC, STANDARD, WHITE, SOLID FOR STOP LINE, 24" LF 148 148 148
711-11-141 THERMOPLASTIC, STANDARD, WHITE, 2-4 DOTTED GUIDELINE/ 6-10 GAP EXTENSION, 6" GM 0.08 0.08
2-4 DOTTED GUIDELINE GM 0.06
6-10 GAP EXTENSION GM 0.02 0.01
711-11-170 THERMOPLASTIC, STANDARD, WHITE, ARROW EA 7 7
(LEFT) EA 1 5 1
711-11-224 THERMOPLASTIC, STANDARD, YELLOW, SOLID, 18" FOR DIAGONALS AND CHEVRONS LF 57 57 57
711-11-241 THERMOPLASTIC, STANDARD, YELLOW, 2-4 DOTTED GUIDELINE/ 6-10 GAP EXTENSION, 6" GM 0.04 0.04
2-4 DOTTED GUIDELINE GM 0.01 0.03
711-14-123 THERMOPLASTIC, PREFORMED, WHITE, SOLID, 12" FOR CROSSWALK LF 647 647 647
711-14-125 THERMOPLASTIC, PREFORMED, WHITE, SOLID, 24" FOR CROSSWALK LF 589 589 589
711-14-160 THERMOPLASTIC, PREFORMED, WHITE, MESSAGE (BIKE) EA 4 4 4
711-14-170 THERMOPLASTIC, PREFORMED, WHITE, ARROW (BIKE THRU) EA 4 4 4
711-16-101 THERMOPLASTIC, STANDARD-OTHER SURFACES, WHITE, SOLID, 6" GM 0.02 0.20 0.04 0.26 0.26
711-16-102 THERMOPLASTIC, STANDARD-OTHER SURFACES, WHITE, SOLID, 8" GM 0.01 0.02 0.01 0.04 0.04
711-16-131 THERMOPLASTIC, STANDARD-OTHER SURFACES, WHITE, SKIP, 6",10-30 GM 0.11 0.11 0.11
711-16-201 THERMOPLASTIC, STANDARD-OTHER SURFACES, YELLOW, SOLID, 6" GM 0.08 0.15 0.03 0.26 0.26
920-714-100 GREEN COLORED PAVEMENT MARKINGS, BIKE LANE SF 365 365 365
PUBLIC WORKS ADMINISTRATION
601 E. KENNEDY BLVD.
TAMPA, FLORIDA 33602
cr (waters ave) at florida mining blvd584
8/28/2025vserpekian P:\HCE1701\31-Waters at Florida Mining\CADD\69679026\signals\TABQSG01.dgn12:06:53 PM
REVISIONS
DATE DESCRIPTION
T
F I
C I
C O
E E
T
E C
T R
O N
G I
T A
L
G N
A L
D
L E
G
A
ELEMENT ENGINEERING GROUP, LLC
P.E. LICENSE NUMBER 82646
T-3
TABULATION OF QUANTITIES
TABULATION OF SIGNALIZATION QUANTITIES
NO.
ITEM
PAY
DESCRIPTION UNIT
SHEET NUMBERS
SHEET
THIS
TOTAL
TOTAL
GRAND
T-9 T-10 T-11
PLAN FINAL PLAN FINAL PLAN FINAL PLAN FINAL PLAN FINAL PLAN FINAL PLAN FINAL PLAN FINAL PLAN FINAL
611-1-1 ITSFM SUBSURFACE DOCUMENTATION- PROJECT LENGTH MI 0.10 0.10 0.10
611-2-1 ITSFM LOCATION DOCUMENTATION- INTERSECTION EA 1 1 1
630-2-11 CONDUIT (F&I) (OPEN TRENCH) LF 570 625 1195 1195
630-2-12 CONDUIT (F&I) (DIRECTIONAL BORE) LF 265 265 265
632-7-1 SIGNAL CABLE (NEW OR RECONSTRUCTED INTERSECTION) (F&I) PI 1 1 1
633-1-121 FIBER OPTIC CABLE (F&I) (UNDERGROUND) (2-12 FIBERS) LF 925 925 925
633-1-122 FIBER OPTIC CABLE (F&I) (UNDERGROUND) (12-48 FIBERS) LF 710 710 710
633-1-420 FIBER OPTIC CABLE (RELOCATE) (UNDERGROUND) LF 1815 1815 1815
633-2-31 FIBER OPTIC CONNECTION (INSTALL) (SPLICE) EA 64 64 64
633-2-32 FIBER OPTIC CONNECTION (INSTALL) (TERMINATION) EA 12 12 12
633-3-11 FIBER OPTIC CONNECTION HARDWARE (F&I) (SPLICE ENCLOSURE) EA 3 3 3
633-3-12 FIBER OPTIC CONNECTION HARDWARE (F&I) (SPLICE TRAY) EA 5 5 5
633-3-14 FIBER OPTIC CONNECTION HARDWARE (F&I) (BUFFER TUBE FAN OUT KIT) EA 1 1 1
633-3-16 FIBER OPTIC CONNECTION HARDWARE (F&I) (PATCH PANEL - FIELD TERMINATED) EA 1 1 1
633-3-17 FIBER OPTIC CONNECTION HARDWARE (F&I) (CONNECTOR PANEL) EA 1 1 1
633-4-1 SIGNALS COMMUNICATION CABLE (TWISTED PAIR CABLE) (F&I) LF 710 710 710
633-6 FIBER OPTIC CABLE LOCATOR DA 226 226 226
635-2-11 PULL & SPLICE BOX (F&I) (13" x 24" COVER SIZE) EA 3 3 3
635-2-12 PULL & SPLICE BOX (F&I) (24" x 36" COVER SIZE) EA 1 1 1
635-2-13 PULL & SPLICE BOX (F&I) (30" x 60" COVER SIZE) EA 1 1 1
635-2-14 PULL & SPLICE BOX (F&I) (17" x 30" COVER SIZE) EA 14 14 14
639-1-122
COMPANY)
ELECTRICAL POWER SERVICE (F&I) (UNDERGROUND, METER PURCHASED BY CONTRACTOR FROM POWER
AS 1 1 1
639-2-1 ELECTRICAL SERVICE WIRE (F&I) LF 245 245 245
639-3-11 ELECTRICAL SERVICE DISCONNECT, F&I, POLE MOUNT EA 1 1 1
641-2-12 PRESTRESSED CONCRETE POLE (F&I) (P-II SERVICE POLE) (12') EA 2 2 2
646-1-11 ALUMINUM SIGNALS POLE (PEDESTAL) EA 8 8 8
649-23-2 STEEL MAST ARM ASSEMBLY (INSTALL) (CONTRACTOR PROVIDED FOUNDATION) EA 2 2 2
650-1-11 VEHICULAR TRAFFIC SIGNAL (F&I ALUMINUM) (1 SECTION) (1 WAY) AS 8 8 8
650-1-14 VEHICULAR TRAFFIC SIGNAL (F&I ALUMINUM) (3 SECTION) (1 WAY) AS 12 12 12
650-1-16 VEHICULAR TRAFFIC SIGNAL (F&I ALUMINUM) (4 SECTION) (1 WAY) AS 2 2 2
653-1-11 PEDESTRIAN SIGNAL (F&I) (LED COUNTDOWN) (1 WAY) AS 8 8 8
660-3-11 VEHICLE DETECTION SYSTEM (MICROWAVE) (FURNISH & INSTALL) (CABINET EQUIPMENT) EA 1 1 1
660-3-12 VEHICLE DETECTION SYSTEM (MICROWAVE) (FURNISH & INSTALL) (ABOVE GROUND EQUIPMENT) EA 4 4 4
663-1-111 SIGNAL PRIORITY AND PREEMPTION SYSTEM (F&I) (OPTICAL) (CABINET ELECTRONICS) EA 1 1 1
663-1-112 SIGNAL PRIORITY AND PREEMPTION SYSTEM (F&I) (OPTICAL) (DETECTOR) EA 2 2 2
665-1-11 PEDESTRIAN DETECTOR (F&I) (STANDARD) EA 8 8 8
670-5-112 TRAFFIC CONTROLLER ASSEMBLY (F&I) (NEMA) (2 PREEMPTION) AS 1 1 1
676-1-132 32" H x 14" D)
TRAFFIC SIGNAL CONTROLLER CABINET (F&I W/OUT CONTROLLER) (NEMA UNWIRED SIZE 2) (20" W x
EA 1 1 1
682-1-143 ITS CCTV CAMERA, F&I, EXTERNAL POSITIONER PTZ- NON-PRESSURIZED, IP, HIGH DEFINITION EA 1 1 1
684-1-1 MANAGED FIELD ETHERNET SWITCH (F&I) EA 1 1 1
685-1-14 UNINTERRUPTIBLE POWER SUPPLY (F&I) (ONLINE/DOUBLE CONVERSION WITH CABINET) EA 1 1 1
700-3-201 SIGN PANEL (F&I) (OVERHEAD MOUNT) (UP TO 12 SF) EA 2 2 2
700-5-22 INTERNALLY ILLUMINATED SIGN (F&I) (OVERHEAD MOUNT) (12-18 SF) EA 4 4 4
PUBLIC WORKS ADMINISTRATION
601 E. KENNEDY BLVD.
8/28/2025vserpekian P:\HCE1701\31-Waters at Florida Mining\CADD\69679026\signals\GNNTSG01.dgn12:06:55 PM
REVISIONS
DATE DESCRIPTION
T
F I
C I
C O
E E
T
E C
T R
O N
G I
T A
L
G N
A L
D
L E
G
A
ELEMENT ENGINEERING GROUP, LLC
P.E. LICENSE NUMBER 82646
VICKEN SERPEKIAN, P.E., P.T.O.E.
GENERAL
OTHER SIGNING AND PAVEMENT MARKING NOTES
SIGNING AND PAVEMENT MARKING PLAN ABBREVIATIONS:
T-4
GENERAL NOTES
THE ROAD.
THE CONTROLLER CABINET BASE SHALL BE AT LEAST AS HIGH AS THE CROWN OF 1.
4-2", + 1-1" CONDUITS CONNECTED TO NEAREST PULLBOXES.
EACH MAST ARM OR STEEL STRAIN POLE FOUNDATION SHALL HAVE AT A MINIMUM OF5.
CONSTRUCTION.
ALL CONDUIT MUST BE INSTALLED PRIOR TO ROADWAY BASE OR SIDEWALK4.
ALL CONDUIT MUST BE 2 INCH MINIMUM UNLESS OTHERWISE SPECIFIED IN PLANS.3.
LEG OF THE INTERSECTION.
A MINIMUM OF FIVE CONDUITS MUST BE PROVIDED BETWEEN THE CORNERS OF EACH2.
BY BORING OR TRENCHING.
NOTE THAT NO TEST BORINGS WERE MADE WHERE CONDUIT RUNS ARE TO BE INSTALLED 1.
AND CABINET FOUNDATION.
BETWEEN PULLBOXES AND SPLICE VAULTS, AND BETWEEN PULLBOXES OR SPLICE VAULT
ITS /COMMUNICATION CONDUITS WILL BE MINIMUM 2-2” CONDUITS BETWEEN PULLBOXES,1.
HILLSBOROUGH COUNTY STANDARD SIGNALIZATION NOTES
HILLSBOROUGH COUNTY STANDARD CONTROLLER NOTES
HILLSBOROUGH COUNTY STANDARD SIGNALIZATION CONDUIT / PULL BOXES NOTES
HILLSBOROUGH COUNTY STANDARD INTERCONNECT CONDUIT TRUNK NOTES
HILLSBOROUGH COUNTY STANDARD PAY ITEM NOTES
CONTRAST BLOCK WITH BIKE SYMBOLS AND ARROWS.
5. REFER TO HILLSBOROUGH COUNTY INDEX GCB-001 FOR PLACEMENT OF GREEN COLORED
SPECIFICATION 710 FOR THE NUMBER OF APPLICATIONS REQUIRED.
(FINAL SURFACE). THE QUANTITIES SHOWN ARE FOR ONE APPLICATION; SEE
THERMOPLASTIC, INCLUDES THE COST FOR PAINTED PAVEMENT MARKINGS
ALL THERMOPLASTIC PAVEMENT MARKING PAY ITEMS, EXCEPT FOR THE PREFORMED4.
ADJACENT TO EXISTING FIRE HYDRANTS FOLLOWING STANDARD PLANS INDEX 706-001.
B/B RPM'S LOCATIONS SHOWN ARE APPROXIMATE. ALL B/B RPM'S SHALL BE PLACED 3.
UNLESS OTHERWISE NOTED.
ALL EXISTING SIGNS WITHIN THE LIMITS OF THE PROJECT ARE EXISTING TO REMAIN,2.
STANDARD PLANS INDEX. FDOT
PLACE ALL PAVEMENT MARKINGS AS SHOWN IN THE PLANS AND THE APPROPRIATE1.
HILLSBOROUGH COUNTY STANDARD SIGNING AND PAVEMENT MARKING NOTES
RECORD.
DIRECTION OF THE CONSTRUCTION PROJECT MANAGER AND/OR THE ENGINEER OF
SIGN LOCATIONS SHOWN ARE APPROXIMATE. ANY FIELD ADJUSTMENT MUST BE AT THE 4.
UNNECESSARY DAMAGE TO THE SIGNS. DAMAGED SIGNS MUST BE REPLACED.
CAUTION MUST BE EXERCISED WHILE RELOCATING EXISTING SIGNS TO PREVENT 3.
USE BY HILLSBOROUGH COUNTY PUBLIC WORKS TRAFFIC OPERATIONS.
ALL TRAFFIC SIGN POSTS MUST BE COMPATIBLE (MAKE, DESIGN) WITH POSTS NOW IN 2.
ALL EXISTING TRAFFIC SIGNS MUST BE MAINTAINED DURING CONSTRUCTION. 1.
PREFORMED THERMOPLASTICPFTP
MONO-DIRECTIONAL YELLOWMD/Y
BLUE/BLUEB/B
POWER SERVICE FROM THE UTILITY COMPANY SHOULD BE UNDERGROUND.16.
TYPE WITH HAND/MAN OVERLAY.
INCANDESCENT LOOK. THE PEDESTRIAN INDICATIONS MUST BE COUNTDOWN
THE ITE LED STANDARD. THE LED SIGNAL INDICATIONS MUST PROVIDE AN
ALL SIGNAL INDICATIONS AND PEDESTRIAN INDICATIONS MUST BE LED AND MEET15.
NOTE OMITTED.14.
FOUNDATION IS NOT INSTALLED PER PLANS.
APPROVAL MUST BE OBTAINED FROM THE ENGINEER OF RECORD IF THE POLE13.
NOTE OMITTED.12.
NOTE OMITTED.11.
THIS WORK MUST BE DIVIDED AMONG THE ITEM NUMBERS FOR SIGNALIZATION.
DISTANCE OR AS ORDERED BY THE ENGINEER. ALL EXPENSES INCURRED FOR
TREE TRIMMING AND REMOVAL MAY BE REQUIRED TO PROVIDE ADEQUATE SIGHT10.
THE CONTRACTOR MUST HAVE A STATE OF FLORIDA ELECTRICAL CONTRACTOR'S LICENSE.9.
BY THE HILLSBOROUGH COUNTY TRAFFIC OPERATIONS SECTION.
OFF-DUTY POLICE OFFICERS, TEMPORARY SIGNALS, OR BY OTHER MEANS APPROVED
TRAFFIC MUST BE MAINTAINED DURING ANY SPLICING ACTIVITY BY THE USE OF 8.
NOTE OMITTED.7.
PROVIDE SUFFICIENT TIME TO ESTABLISH SIGNAL TIMINGS.
AT LEAST TWO WEEKS IN ADVANCE OF ACTIVATING OF NEW TRAFFIC CONTROLLER TO
TRAFFIC OPERATIONS AND ENGINEERING SECTIONS ((813) 307-1798) MUST BE NOTIFIED
NOTIFIED AT LEAST 48 HOURS IN ADVANCE OF LOOP CUTTING . HILLSBOROUGH COUNTY
HILLSBOROUGH COUNTY TRAFFIC OPERATIONS SECTION AT (813) 612-7900 MUST BE6.
NOTE OMITTED.5.
NOTE OMITTED.4.
NOTE OMITTED.3.
POWER LINES.
CONTACT TECO FOR THEIR ASSISTANCE IN PERFORMING ALL NECESSARY WORK UNDER2.
CONSTRUCTION.
SITES MUST BE LOCATED AND IDENTIFIED BY PROPER AUTHORITIES AT TIME OF
COMPLY WITH THE SUNSHINE 811 RELATED FLORIDA STATUTES. UNDERGROUND CABLE1.
OTHER SIGNALIZATION PAY ITEM NOTES:
COMMUNICATION WIRE TO BE USED.
633-4-1: COORDINATE WITH HILLSBOROUGH COUNTY FOR THE TYPE OF COPPER 2.
LINE RELOCATIONS.
SIGNAL COMMUNICATION LINE ARE INCIDENTAL TO THE COST OF THE FIBER OPTIC
633-1-420: ALL COSTS AND EQUIPMENT REQUIRED FOR THE RELOCATION OF COPPER 1.
YELLOW/YELLOWY/Y
WHITE/REDW/R
REFER TO THE UTILITY ADJUSTMENT SHEETS FOR UTILITY INFORMATION.3.
TRAFFIC ENGINEERING, BOB CAMPBELL, AT (813) 235-5980.
ERIC TIDWELL, SIGN SHOP SUPERVISOR, AT (813) 440-7253 AND
TRAFFIC OPERATIONS, DARRYLE NORTON, SIGNAL SUPERVISOR AT (813) 399-2848 AND
CONTACT INFORMATION: 2.
HEREIN. THE PLAN SHEETS MUST BE SIGNED AND SEALED.
ELECTRIC CODE AND NATIONAL ELECTRICAL SAFETY CODE WILL APPLY TO ALL WORK
ENGINEERING MANUAL, MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES, NATIONAL
PUBLIC WORKS STANDARD SPECIFICATIONS FOR CONSTRUCTION, FDOT TRAFFIC
HILLSBOROUGH COUNTY TRANSPORTATION TECHNICAL MANUAL, HILLSBOROUGH COUNTY
TRAFFIC CONTROL DEVICES, HILLSBOROUGH COUNTY UTILITY ACCOMMODATION GUIDE,
ROADWAY AND TRAFFIC DESIGN STANDARDS, FDOT MINIMUM SPECIFICATIONS FOR
EDITION DIVISION II AND III WITH ALL APPLICABLE ADDENDUMS/CHANGES, FDOT
F.D.O.T. STANDARD SPECIFICATIONS FOR ROAD AND BRIDGE CONSTRUCTION, CURRENT1.
NOTE OMITTED.17.
NOTE OMITTED.16.
CONNECTION USED BY HILLSBOROUGH COUNTY TRAFFIC OPERATIONS.
OR ETHERNET PORT (RJ45) FOR LOCAL CONTROL VIA A LAPTOP OR REMOTE NETWORK
WITH THE CURRENT MAKE, MODEL AND PROVIDE A SERIAL DATA CONNECTION PORT AND
PRODUCT LIST. THE CONTRACTOR MUST ENSURE THE MAKE AND MODEL IS CONSISTENT
ASSEMBLY PAY ITEM. THE UPS ASSEMBLY MUST BE LISTED ON THE FOOT APPROVED
FOUNDATION MATERIAL AND LABOR MUST BE INCLUDED IN THE TRAFFIC CONTROLLER
DIRECTLY TO THE CONCRETE FOUNDATION PAYMENT FOR THE ADDITIONAL CONCRETE
ENOUGH TO PROVIDE A FOOT PRINT FOR THE UPS CABINET TO BE BOLTED
CONTROLLER EQUIPMENT. THE TRAFFIC SIGNAL CONCRETE BASE MUST BE LARGE
DESIGNED TO HOUSE THE UPS ASSEMBLY IN ADDITION TO THE TRAFFIC SIGNAL
A SEPARATE ENCLOSED CABINET OR IN A TRAFFIC SIGNAL CABINET WHICH IS
15. 685-1-14: THE UNINTERRUPTED POWER SUPPLY (UPS) UNIT MUST BE HOUSED IN
/POWER CORD.
DEVICE-LEVEL MANAGED FIELD ETHERNET SWITCH (MFES) WITH POWER SUPPLY
684-1-1: FOLLOW THE CURRENT FDOT STANDARD FURNISH AND INSTALL A HARDENED,14.
NOTE OMITTED.13.
PAN AND TILT ROTATION. SINGLE CAT5E/CAT6 WITH POE++ WITH 20 FOOT PIG TAIL.
WIDE DYNAMIC RANGE AND DEFOG MODES. ENG PAN/TILT MOTION. CONTINUOUS 360
DEFINITION 20X30 OPTICAL ZOOM LENS, HYDROPHILIC SELF CLEANING GLASS WINDOW.
12. 682-1-143: ITS CCTV CAMERA EXTERNAL POSITIONER PTZ-NON-PRESSURIZED IP HIGH
PRODUCT LIST.
THE CONTROLLER AND CONTROLLER CABINET MUST BE LISTED ON THE FDOT APPROVED
NECESSARY CONTROLS BASED ON THE DESIGN OF THE SIGNALIZED INTERSECTION.
MUST ENSURE THE CONTROLLER CABINET WILL FULLY FUNCTION AND PROVIDE
DESIGN OF THE INTERSECTION. THE DESIGNER, CONTRACTOR AND CABINET VENDOR
INTERFACE EQUIPMENT OR MODULES WITHIN THE CABINET WILL BE BASED ON THE PLAN
THE CONTROLLER CABINET MUST BE PROVIDED WITH AN ATC CONTROLLER. ADDITIONAL
HILLSBOROUGH COUNTY PUBLIC WORKS STANDARD SPECIFICATION FOR CONSTRUCTION.
THE CONTROLLER CABINET MUST MEET THE SPECIFICATIONS DOCUMENTED IN THE
MUST BE COMPATIBLE WITH THE HILLSBOROUGH COUNTY CENTRAL COMPUTER SYSTEM.
670-5-112, 670-5-400: ACTUATED SOLID STATE CONTROLLER ASSEMBLY: THE CONTROLLER11.
NOTE OMITTED.10.
MUST BE USED.
665-1-11: ADA PIEZO PUSHBUTTONS WITH RAISED ARROW AND AUDIBLE INDICATION9.
COORDINATE WITH HILLSBOROUGH COUNTY TRAFFIC FOR UNIT ACCEPTANCE.
OPTIMAL MOUNTING LOCATIONS FOR THE ABOVE GROUND DETECTION DEVICES.
RECORD MUST COORDINATE WITH THE MANUFACTURER DURING DESIGN TO DETERMINE
EQUIPMENT, CABINET, AND TRAFFIC SIGNAL COMPUTER SYSTEM. THE ENGINEER OF
THE MICROWAVE (RADAR) SYSTEM MUST BE COMPATIBLE WITH HILLSBOROUGH COUNTY'S
ANY ADDITIONAL EQUIPMENT REQUIRED TO MAKE A COMPLETE AND ACCEPTABLE SYSTEM.
DEVICES, PROCESSORS, INTERFACE UNITS, CABLE PLANTS, MOUNTING BRACKETS, AND
MEDIANS. THE DETECTION SYSTEM WILL INCLUDE MICROWAVE (RADAR) DETECTION
A DISTANCE UP TO 140 FEET, IN CURVED LANES, AND IN AREAS WITH ISLANDS AND
TO 10 LANES AND A RADAR CAPABLE OF DETECTING PRESENCE IN DIFFERENT LANES AT
RESOLUTION BANDWIDTH OF 245MHZ, A MULTI-BEAM RADAR CAPABLE OF COVERING UP
INSTALL A MICROWAVE (RADAR) VEHICLE DETECTION SYSTEM THAT UTILIZES
660-3-11 AND 660-3-12: MUST INCLUDE ALL LABOR AND MATERIALS TO FURNISH AND8.
NOTE OMITTED.7.
NOTE OMITTED.6.
DRILLED SHAFT AND SPECIAL FOUNDATIONS ARE INCLUDED IN THIS PAY ITEM.
COMPARTMENT HAND HOLE FOR ALL MAST ARMS. ALL COSTS ASSOCIATED WITH THE
649-23-2: MUST INCLUDE 7" MIN. - 8 1/2" MAX. BY 2' MIN. - 2'-6" MAX. TERMINAL5.
646-1-11: MUST INCLUDE BREAKAWAY SUPPORT (TRANSFORMER TYPE BASE).4.
MUST HAVE A MINIMUM DESIGN/TEST LOAD OF 22,500 (DESIGN)/33,750 (FEET) LBS.
MINIMUM DESIGN/TEST LOAD OF 15,000 (DESIGN)/22,500 (TEST) LBS. THE PULLBOX
635-2-11 AND 635-2-14: THE PULLBOX COVER/LID MUST BE HEAVY DUTY AND HAVE A3.
COMPONENTS WILL BE SC TYPE CONNECTORS
OF THE CONNECTOR TYPE. HILLSBOROUGH COUNTY MAINTAINED EQUIPMENT/
CONNECTOR PANELS FOLLOW THE FDOT CURRENT STANDARD WITH THE EXCEPTION
633-2-31, 633-2-32: ALL PATCH PANELS, PRE-TERMINATED PATCH PANELS, AND2.
632-7-1: WIRE EACH PHASE/MOVEMENT AS A SEPARATE PHASE/MOVEMENT. 1.
PUBLIC WORKS ADMINISTRATION
WATER
WATER
WATER
SD
STOP
ONLY
STOP
TO REMAIN
EXISTING SIGN
TO REMAIN
EXISTING SIGN
H
IG
H W
A Y
E N
T E
R
IN
G
T R
U C
K
2 EA*
HILLSBOROUGH COUNTY
RETURN SIGN ASSEMBLY TO
*CONTRACTOR SHALL
700-1-600
186 187
SD
E A S T
H
IL
L S
B O
R O
U G
H
C O
U N
T Y
H
IL
T O
N H
O T
E L S
B E
A U
T
IF
U L
T A
M P
A B
A Y
K E
E P
E N
F O
R C
E D
P H
O T
O
R
IG
H T T
U R
N
IN
C
L U
D E
S
GS-1
7'-6"x2'-6"
TO REMAIN
EXISTING SIGN
STA. 183+34
RELOCATE TO
STA. 180+71
W R
O N
G
W A
Y
TO REMAIN
EXISTING SIGN
42"x30"
W R
O N
G
W A
Y
R5-1A
STA. 180+42
700-13-15 1 EA
CANTILEVER)
(SINGLE POST
700-1-600
700-1-111
700-1-1121 EA 1 EA
1 EA
SD
SD
WATER
WATER
WATER
SD
WATER
STOP
D
O N
O T
B L
O C
K
D R
IV
E W
A Y
H
IL
T O
N H
O T
E L S
B E
A U
T
IF
U L
T A
M P
A B
A Y
K E
E P
H
IL
L S
B O
R O
U G
H
C O
U N
T Y
E A S T
M1-6
24"x24"
24"x12"
M3-2
TO REMAIN
EXISTING SIGN
TO REMAIN
EXISTING SIGN
STA. 183+34
STA. 181+86
STOP
L L
T O
TO REMAIN
EXISTING SIGN
TO REMAIN
EXISTING SIGN
36"x12"
R6-1R
D O N
O T
E N
T E
R
D O N
O T
E N
T E
R
TO REMAIN
EXISTING SIGN
ONE WAY
STA. 182+40
36"x36"
DO NOT
ENTER
R5-1
36"x36"
36"x36"
R5-1
R3-18L
STA. 181+63
STA. 180+24
RELOCATED FROM
700-1-600
700-1-111
700-1-112
700-1-112
700-1-500 1 EA
1 EA
1 EA
1 EA
1 EA
182 183 184
CR 584 (WATERS AVE)
N 10 40
Feet
M A
T C
H
L I N
E
S
T A
.0
R/W LINE
£ SURVEY
R/W LINE
R/W LINE
R/W LINE
240'
R/W LINE
R/W LINE
STA. 179+75.43
BEGIN CONSTRUCTION
R/W LINE
78'
RPM'S 20' OC
6" WHITE WITH W/R
6/10 SKIP
6" WHITE
6" YELLOW
+56
+73+86
+08+63 +83
+62+01
+43
+33
6" WHITE
6" YELLOW
6" YELLOW
18" WHITE 10' OC
6" YELLOW 2/4 SKIP
DIRECTIONAL ARROW
W/R RPM'S 10' OC
8" WHITE WITH
STA. 180+33.00
BEGIN PROJECT
R/W LINE
6" YELLOW
8" OC
PAINT WITH MD/Y RPM'S
REFLECTIVE YELLOW NOSE
8" OC
PAINT WITH MD/Y RPM'S
REFLECTIVE YELLOW NOSE
8/28/2025vserpekian P:\HCE1701\31-Waters at Florida Mining\CADD\69679026\signing\PLANSP01.dgn12:08:50 PM
REVISIONS
DATE DESCRIPTION
T
F I
C I
C O
E E
T
E C
T R
O N
G I
T A
L
G N
A L
D
L E
G
A
ELEMENT ENGINEERING GROUP, LLC
P.E. LICENSE NUMBER 82646
VICKEN SERPEKIAN, P.E., P.T.O.E.
T-5
SIGNING AND PAVEMENT
MARKING PLAN
PUBLIC WORKS ADMINISTRATION
8/28/2025vserpekian P:\HCE1701\31-Waters at Florida Mining\CADD\69679026\signing\PLANSP02.dgn12:08:59 PM
REVISIONS
DATE DESCRIPTION
T
F I
C I
C O
E E
T
E C
T R
O N
G I
T A
L
G N
A L
D
L E
G
A
ELEMENT ENGINEERING GROUP, LLC
P.E. LICENSE NUMBER 82646
VICKEN SERPEKIAN, P.E., P.T.O.E.
PUBLIC WORKS ADMINISTRATION
601 E. KENNEDY BLVD.
TAMPA, FLORIDA 33602
cr (waters ave) at florida mining blvd584
SAN
SAN
WATER
WATER
SAN
GAS
WATERWATER
WATER
GAS
SD
WATER
WATER
PS
SAN
SAN
COMM
WATER
WATER
EOI
TEL
7'
7'
7'
7'
7'
7'
9'
12'
H A
R T
B U
S S
T O
P
AVEWaters
B L
V D
F lo r id in g
AVE Waters
B L
V D
F lo r id g
A D E
N D
D E A D E
N D
FEDEX GROUND
BEAUTIFUL
TAMPA BAY
KEEP
STOP
S a v a re s e B lv d N
E X
T S
IG
N
A L
OUTLET
NO
36"x36"
W14-2
END
DEAD
TO REMAIN
EXISTING SIGN
R4-7
24"x30"
18"x18"
STA. 189+15
705-10-1 1 EA
OM1-3
R4-7
24"x30"
18"x18"
STA. 190+73
705-10-1 1 EA
OM1-3
STA. 189+19
STA. 11+53 � CONST.
STA. 11+03 � CONST.
700-1-600
700-1-600
700-1-600
700-1-111
700-1-111
700-1-111
700-1-500
700-1-500
1 EA
1 EA
1 EA
1 EA
1 EA
1 EA
1 EA
1 EA
187 188 189 190 191 192
R/W LINE
R/W LINE
R/W LINE
R/W LINER/W LINE
R/W LINE
CR 584 (WATERS AVE)
N 10 40
Feet
F L
O R I
N I
G
V D
£ SURVEY
M A
T C
H
L I N
E
S
T A
.0
M A
T C
H
L I N
E
S
T A
.0
STA. 10+00.00, ¡ CONST.
EQ: STA. 189+82.87, £ SURVEY =
W/R RPM'S 40' OC
6" WHITE 10/30 SKIP WITH
6" YELLOW
6" YELLOW
W/R RPM'S 40' OC
6" WHITE 10/30 SKIP WITH
45' RT
+94
56' RT
+88
56' RT
+52
45' RT
+46
62' RT
+70
+24
57' LT
+35
69' LT
+55
60' LT
+36
71' LT
+20
+52
RPM'S 20' OC
6" WHITE WITH W/R
W/R RPM'S 40' OC
6" WHITE 10/30 SKIP WITH
+70+63
6" WHITE
6" WHITE
6" WHITE
6" WHITE 2/4 SKIP
Y/Y RPM'S 40' OC
6" DOUBLE YELLOW WITH
24" WHITE
24" WHITE
+50
+61
+20
+70
10' WIDE (TYP.)
12" WHITE PFTP
24" WHITE
+18
+80
+68
+18
+18
+35
75' LT
+90
24" WHITE
6" WHITE
RPM'S 20' OC
6" WHITE WITH W/R
DIRECTIONAL ARROW (TYP.)
12' 12' 11'
¡ CONST.
PFTP (TYP.)
24" WHITE
6" YELLOW
STA. 192+50.00
END PROJECT
6" WHITE 6/10 SKIP
MARKINGS (TYP.)
MATCH EXISTING PAVEMENT
MARKINGS (TYP.)
MATCH EXISTING PAVEMENT
B/B RPM
8" OC (TYP.)
PAINT WITH MD/Y RPM'S
REFLECTIVE YELLOW NOSE
� CONST.
57' LT
+31
87' LT
+01
RPM'S 10' OC
8" WHITE WITH W/R
PAVEMENT MARKINGS (TYP.)
WITH GREEN COLORED
BIKE MESSAGE AND ARROW
MARKINGS (TYP.)
MATCH EXISTING PAVEMENT
MARKINGS (TYP.)
MATCH EXISTING PAVEMENT
6" YELLOW
RPM'S 20' OC
6" WHITE WITH W/R
RPM'S 40' OC
6" WHITE WITH W/R
6" WHITE
10' OC (TYP.)
18" WHITE
RPM'S 10' OC
8" WHITE WITH W/R
+45
+41
Y/Y RPM'S 5' OC
YELLOW WITH
6" DOUBLE
5' OC (TYP.)
18" YELLOW
5' OC (TYP.)
18" YELLOW
MARKER (TYP.)
YELLOW TUBULAR
PFTP (TYP.)
24" WHITE
Y/Y RPM'S 5' OC
YELLOW WITH
6" DOUBLE
+70
+89
2-4 SKIP
6" YELLOW,
2-4 SKIP
6" YELLOW,
'R
120'R
'R
46' LT
+89
4' RT
+63
RIGHT OF ENTRY LINE
2/4 SKIP
6" WHITE
OTHERWISE NOTED
SHEET ARE BASED ON £ SURVEY UNLESS
ALL STATIONS AND OFFSET LABELS ON THIS
NOTE:
SEE SHEET -
T-6
MATCH LINE STA. 11+60.00 ¡ CONST.
25'
1' 6' 6' 6' 1'
6" WHITE
PAVEMENT MARKINGS
GREEN COLORED
STOP LINE
24" WHITE
CONTRAST BLOCK
PLACEMENT OF GREEN COLORED
R
.2
R
.7
T-8
8/28/2025vserpekian P:\HCE1701\31-Waters at Florida Mining\CADD\69679026\signing\PLANSP03.dgn12:09:17 PM
REVISIONS
DATE DESCRIPTION
T
F I
C I
C O
E E
T
E C
T R
O N
G I
T A
L
G N
A L
D
L E
G
A
ELEMENT ENGINEERING GROUP, LLC
P.E. LICENSE NUMBER 82646
VICKEN SERPEKIAN, P.E., P.T.O.E.
PUBLIC WORKS ADMINISTRATION
601 E. KENNEDY BLVD.
TAMPA, FLORIDA 33602
cr (waters ave) at florida mining blvd584
WATER
H
IG
H W
A Y
E N
T E
R
IN
G
T R
U C
K
2 EA*
HILLSBOROUGH COUNTY
RETURN SIGN ASSEMBLY TO
*CONTRACTOR SHALL
700-1-600
WATER
WATER
WATER
WATER
WATER
WATER
WATER
WATER
WATERWATER
WATER
WATER
WATER
WATER
WATER WATER
WATER
WATER
1 AS
GS-2
7'-0"x4'-0"
STA. 199+00
CANTILEVER)
(SINGLE POST
700-1-113
196 197 198 199
N 10 40
Feet
M A
T C
H
L I N
E
S
T A
.0
CR 584 (WATERS AVE)
R/W LINE
STA. 199+00.00
END CONSTRUCTION
£ SURVEY
180'
CR 584 (WATERS AVE)
£ SURVEY
T-7
8/28/2025vserpekian P:\HCE1701\31-Waters at Florida Mining\CADD\69679026\signing\PLANSP04.dgn12:10:01 PM
REVISIONS
DATE DESCRIPTION
T
F I
C I
C O
E E
T
E C
T R
O N
G I
T A
L
G N
A L
D
L E
G
A
ELEMENT ENGINEERING GROUP, LLC
P.E. LICENSE NUMBER 82646
VICKEN SERPEKIAN, P.E., P.T.O.E.
PUBLIC WORKS ADMINISTRATION
601 E. KENNEDY BLVD.
TAMPA, FLORIDA 33602
cr (waters ave) at florida mining blvd584
S A
N
S A
N
W A T E R
W A T E R
W A T E R
S A
N
E L
E C
12 13 14
N
10 40
Feet
FLORIDA MINING BLVD
DIRECTIONAL ARROW
+27
ALL STATIONS AND OFFSET LABELS ON THIS SHEET ARE BASED ON � CONST.
NOTE:
MARKINGS (TYP.)
MATCH EXISTING PAVEMENT
Y/Y RPM' 40' OC
6" DOUBLE YELLOW WITH
RPM'S 20' OC
6" WHITE WITH W/R
6" WHITE
R/W LINE
¡ CONST.
R/W LINE
STA. 12+53.21 � CONST.
END CONSTRUCTION
B/B RPM
+47
BEGIN 6" WHITE
+83 END 8" WHITE
E
S
H E
E
T C
H
L I N
E
S
T A
.0
C
O N
S T
T-8
8/28/2025vserpekian P:\HCE1701\31-Waters at Florida Mining\CADD\69679026\signals\PLANSG01.DGN12:10:52 PM
REVISIONS
DATE DESCRIPTION
T
F I
C I
C O
E E
T
E C
T R
O N
G I
T A
L
G N
A L
D
L E
G
A
ELEMENT ENGINEERING GROUP, LLC
P.E. LICENSE NUMBER 82646
VICKEN SERPEKIAN, P.E., P.T.O.E.
PUBLIC WORKS ADMINISTRATION
SAN
SAN
WATER
WATER
WATER
WATER
GAS
WATERWATER
WATER
GAS
SD
WATER
WATER
PS
SAN
SAN
COMM
TEL
TEL
0.5'
.5
WATER
WATER
TEL
TEL
SAN
SAN
EOI
TEL
7'
7'
7'
7'
7'
7'
9'
12'
DZ-6
DZ-6
DZ-6
DZ-1
DZ-5
DZ-2
DZ-2
DZ-2
D Z -8
D Z -8
R
D Z -4
C
191190189188
R
R
R
R
SAN
SAN
ELEC
F L
O R I
N I
V D
CR 584 (WATERS AVE)
CRIT. EL. 27.3
CRIT. EL. 26.4
ARM 2
ARM 1
ARM 1
ARM 2
R/W LINE
R/W LINE
1 EA
1 AS
1 EA
1 EA
100 LF
1 EA (12')
MW 1
MW 2
MW 3
MW 4 1 EA
2 EA
1 EA
2 EA
T-9
SIGNALIZATION PLAN
CRIT. EL. 26.5
¡ CONST.
V
145 LF
1 AS
1 EA (12')
1 EA
1 EA
2 EA
POWER SOURCE
CRIT. EL. 27.1
F L
O R I
N I
V D
R/W LINE
R/W LINE
R/W LINE
R/W LINE
R/W LINE
R/W LINE
R/W LINE
1 EA
MATCH LINE STA. 11+80.00 ¡ CONST.
MATCH LINE STA. 11+80.00 ¡ CONST.
MAST ARM UPRIGHT
HEAD MOUNTED TO
SUPPLEMENTAL SIGNAL
CCTV
2 EA
**** 1 EA
1 EA
1 EA
1 EA
RIGHT OF ENTRY LINE
(3) HV AND (2) LV)
15 LF (5 RUNS,
(1) HV AND (1) LV)
25 LF (2 RUNS, (1) HV AND (1) LV)
35 LF (2 RUNS,
(1) HV AND (1) LV)
70 LF (2 RUNS,
(1) HV AND (1) LV)
90 LF (2 RUNS,
(1) HV AND (1) LV)
30 LF (2 RUNS,
(3) HV AND (3) LV)
15 LF (6 RUNS,
670-5-112
663-1-111
641-2-12
685-1-14
639-2-1
630-2-11
630-2-11
635-2-11
660-3-11
700-5-22
663-1-112
630-2-11
660-3-12630-2-11
635-2-14
630-2-12
649-23-2 630-2-11
630-2-11
635-2-14
630-2-11
630-2-12
641-2-12
639-2-1
630-2-11
635-2-11
639-1-122
630-2-12
630-2-11
635-2-11
663-1-112
630-2-11
660-3-12
649-23-2
630-2-11
635-2-14
639-3-11
635-2-14
630-2-11
700-5-22
682-1-143
81.3' LT.
STA. 189+54
POLE LOCATION=
EL. = 27.601
30" X 48" PEDESTRIAN LANDING (2% MAX)
EMERGENCY PREEMPTION DETECTOR
CCTV CAMERA
MICROWAVE DETECTOR
LEGEND
P4
P2
P2
P8
P4P8
665-1-11
646-1-11
632-7-11 PI
676-1-132*** 1 EA
P6
P6
4E44E4
2E
2E
6E
6E
8E88E8
£ SURVEY
¡ CONST.
X
W
Z
Y
N
0 30
Feet
3 EA
2 EA
665-1-11
646-1-11
1 EA
V
V
665-1-11
646-1-11
2 EA
2 EA
100 LF (1 RUN, POWER)
15 LF (1 RUN, POWER)
75 LF (1 RUN, POWER)
SPARE AND (1) FOC SPARE)
(1) FOC, (1) HV SPARE, (1) LV
145 LF (9 RUNS, (3) HV, (2) LV,
C
665-1-11
646-1-11
6 EA
2 EA
*2 EA
1 EA *
*2 EA
*2 EA
(1) HV SPARE, AND (1) LV SPARE)
85 LF (7 RUNS, (3) HV, (2) LV,
(1) HV SPARE, AND (1) LV SPARE)
65 LF (4 RUNS, (1) HV, (1) LV,
55 LF (2 RUNS, (1) POWER AND (1) SPARE)
3 EA
665-1-11
646-1-11
1 EA
1 EA *
51.0' RT.
STA. 190+11
POLE LOCATION=
EL. = 26.922
R
**** CCTV CAMERA TO BE MOUNTED TO THE MAST ARM UPRIGHT
OPERATION OF THE POWER OUTAGE EMERGENCY BEACONS ONLY.
TRAFFIC SIGNAL CONTROLLER CABINET. THIS ASSEMBLY IS FOR
RELAY, AND TERMINATION POINTS. RELAY MONITORS AC POWER IN
MAST ARM FOR MAXIMUM SUN EXPOSURE), SOLAR REGULATOR, FLASHER,
TWO 90-WATT (MIN.) SOLAR PANELS (INSTALLED AND POSITIONED ON
POLE MOUNTED CABINET PAY ITEM INCLUDES TWO 105 AH BATTERIES, ***
2-1" CONDUITS.
THE CONTROLLER CABINET FOUNDATION WILL HAVE 13-2" AND **
SEE SPREAD FOOTER DETAILS FOR FOUNDATION DESIGN.
TO A 30'X48" FLAT AREA.
ALL PEDESTRIAN SIGNAL PEDESTALS SHALL BE PLACED ADJACENT *
NOTES:
(4) HV, (5) LV)
** 15 LF (9 RUNS,
8/28/2025vserpekian P:\HCE1701\31-Waters at Florida Mining\CADD\69679026\signals\PLANSG02.DGN12:10:56 PM
REVISIONS
DATE DESCRIPTION
T
F I
C I
C O
E E
T
E C
T R
O N
G I
T A
L
G N
A L
D
L E
G
A
ELEMENT ENGINEERING GROUP, LLC
P.E. LICENSE NUMBER 82646
VICKEN SERPEKIAN, P.E., P.T.O.E.
SIGNAL HEAD DETAILS
ADJUSTING AS DIRECTED BY THE ENGINEER.
TIMINGS ARE INITIAL AND MAY REQUIRE FIELD
P2
P4
4-SECT., 1-WAY
2 AS
650-1-16
R
Y
G
FY
ADJUSTING AS DIRECTED BY PROJECT ENGINEER.
DELAY TIME IS INITIAL AND MAY REQUIRE FIELD
or
PHASE I
2 6
P2
1 5
P2
P2
P8 P4
PHASE IV
P4 P8
PHASE III
SIGN SIGN
SIGN SIGN
SIGN V
2 EA
30"X36"
700-3-201
ARROW
YELLOW
FLASHING
YIELD ON
LEFT TURN
FTP-85-13
(SEE GUIDE SIGN WORKSHEET FOR DETAILS)
INTERNALLY ILLUMINATED SIGNS
PHASE II *
POEB DETAILS
4E
6E2E
8E
* NO BACKPLATES
1-SECT., 1-WAY *
R
650-1-11
8 AS
PED. SIGNAL
COUNT-DOWN
1-SECT., 1-WAY
8 AS
653-1-11
4 8
Z
X
Y
W
OVERHEAD SIGN DETAILS
P2 P6
P6
P6
DURING P2/P6 ACTIVATION
DISPLAY RED INDICATION
* MOVEMENTS 1/5 SHALL
P8
P6
S.O.P. 7
T-10
SIGNALIZATION PLAN
DETECTION
MICROWAVE
DETECTOR
MICROWAVE
ZONE
DETECTION
MW 1 DZ-8
DZ-8R
DZ-6
DZ-1
DZ-5
DZ-2
MW 2
MW 3
MW 4 DZ-4
(SEC)
DELAY
1 2 3 4 5 6 7 8
-ALL RED
YELLOW CLEARANCE
MAXIMUM GREEN 2
RECALL
PED. CLEARANCE
PEDESTRIAN WALK
MAXIMUM GREEN 1
MOVEMENT NUMBER
TIMING FUNCTION
CONTROLLER TIMINGS
T I
M I N
G
F
U N
C T I O
N EXTENSION
MINIMUM GREEN
4.8 4.8 4.8 4.84.8 4.1
5 515 15 -10 10
3.0 3.0 3.0 3.0 3.0 3.0
30 90 30 9030 30
- - - -MAX MAX
2.0 2.0 2.3 2.02.8 2.7
7.0 7.0 7.07.0-
-25 30 11 30
MAIN STREET & SIDE STREET ALTERNATING FLASH.
FOUR-WAY RED INDICATIONS 2E, 4E, 6E, AND 8E IN A WIG-WAG PATTERN WITH
UPON LOSS OF ALL AC POWER, SOLAR ASSEMBLY WILL ACTIVATE AND FLASH THE3.
(UPS) HAS EXPENDED USABLE LIFE).
(UTILITY POWER COMPANY POWER IS LOST AND THE UNINTERRUPTIBLE POWER SUPPLY
THE POEB SHALL OPERATE AFTER COMPLETE LOSS OF AC POWER TO THE SIGNAL2.
MINOR STREET IS FLORIDA MINING BLVD: MOVEMENTS 4E, AND 8E.
MAJOR STREET IS CR 584 (WATERS AVE): MOVEMENTS 2E, AND 6E.1.
POWER OUTAGE EMERGENCY BEACON (POEB) OPERATION NOTES:
P6
Vehicles
Watch For
START CROSSING
If Started
Finish Crossing
DON'T START
To Finish Crossing
TIME REMAINING
DON'T CROSS
STEADY
TIMER
FLASHING
WATERS AVE
TO CROSS
PUSH BUTTON
Vehicles
Watch For
START CROSSING
If Started
Finish Crossing
DON'T START
To Finish Crossing
TIME REMAINING
DON'T CROSS
STEADY
TIMER
FLASHING
FLORIDA MINING BLVD
TO CROSS
PUSH BUTTON
PEDESTRIAN ACTUATION SIGNS
3-SECT., 1-WAY
12 AS
650-1-14
R
Y
G
P4 AND P8 UPON DETECTION ONLY PRIOR TO BEGINNING OF MOVEMENT 4 AND 8 GREEN TIME.
A LEADING PEDESTRIAN INTERVAL (LPI) OF 7.0 SECONDS SHALL BE PROVIDED FOR MOVEMENTS9.
OPTIC CABLE AND SPARE CONDUITS.
LOW VOLTAGE (LV) RUNS INCLUDE: PEDESTRIAN DETECTORS, VEHICLE DETECTION, FIBER
ILLUMINATED SIGNS AND SPARE CONDUITS.
HIGH VOLTAGE (HV) RUNS INCLUDE: POWER, SIGNALS, PEDESTRIAN SIGNALS, INTERNALLY8.
2 FT AHEAD OF STOP BAR.
MICROWAVE DETECTION ZONES FOR ALL OTHER MOVEMENTS SHALL BE 6 FT X 50 FT AND PLACED
AHEAD OF STOP BAR.
MICROWAVE DETECTION ZONE FOR MOVEMENT 4 SHALL BE 6 FT X 20 FT AND PLACED 2 FT7.
(POEB) SHALL REMAIN OFF.
DURING NORMAL AND FLASH MODE OPERATION, POWER OUTAGE EMERGENCY BEACONS6.
OTHER MOVEMENTS SHALL FLASH RED.
DURING FLASH MODE OPERATION, MOVEMENTS 2 AND 6 SHALL FLASH YELLOW AND ALL 5.
OPERATION.
TURN MOVEMENT SHALL HAVE CONDUCTORS AVAILABLE FOR PROTECTED AND PERMISSIVE
AS A SEPARATE PHASE/MOVEMENT. THIS INCLUDES LEFT TURN MOVEMENTS. EACH LEFT
EACH PHASE/MOVEMENT SHALL BE WIRED FROM THE SIGNAL DISPLAY TO THE CONTROLLER4.
SIGNAL SHALL OPERATE WITH A SIGNAL OPERATION PLAN (S.O.P.) OF 7 AS SHOWN BELOW.3.
ALONG FLORIDA MINING BLVD.
THE POSTED SPEED LIMIT IS 45 MPH ALONG CR 584 (WATERS AVE) AND 35 MPH 2.
MINOR STREET IS FLORIDA MINING BLVD: MOVEMENTS 4, 8 AND 8R.
MAJOR STREET IS CR 584 (WATERS AVE): MOVEMENTS 1, 2, 5 AND 6.1.
CONTROLLER OPERATION NOTES:
PUBLIC WORKS ADMINISTRATION
WATER
WATER
SAN
WATER
WATER
GAS
SAN
WATERWATER
WATER
GAS
SD
WATER
WATER
WATER
WATER
PS
SAN
SAN
WATER
WATER
TEL
TEL
SAN
SAN
COMM
C
188 189 190 191 192 193 194
8/28/2025vserpekian P:\HCE1701\31-Waters at Florida Mining\CADD\69679026\signals\PLICSG01.DGN12:12:30 PM
REVISIONS
DATE DESCRIPTION
T
F I
C I
C O
E E
T
E C
T R
O N
G I
T A
L
G N
A L
D
L E
G
A
ELEMENT ENGINEERING GROUP, LLC
P.E. LICENSE NUMBER 82646
VICKEN SERPEKIAN, P.E., P.T.O.E.
T-11
SIGNAL COMMUNICATION
PLAN
N
F L
O R I
N I
V D
CR 584 (WATERS AVE)
STA. 189+82
TO BE REMOVED
EXIST. PULL BOX
Feet
0 10
25 LF (12-CT COIL)
25 LF (24-CT COIL)
STA. 187+81
SEE SPLICING DETAIL SPL-1
EXIST. FIBER PULL BOX
R
R
R
R
615 LF*
FIBER AND COPPER COMMUNICATION))
FIBER PULL BOX (INCLUDES 24-CT & 6-CT
*COIL AS MUCH AS POSSIBLE IN EXIST.
VAULT AT STA. 189+36 THROUGH THE PROPOSED FIBER PULL BOX LOCATED NEAR THE CONTROLLER CABINET.
D) CONNECT THE PROPOSED 12-CT FIBER DROP TO THE PROPOSED CONTROLLER CABINET FROM THE PROPOSED
STA. 189+36.
C) RUN NEW FIBER AND COPPER COMMUNICATION LINES THROUGH PROPOSED CONDUITS TO THE PROPOSED VAULT AT
FIBER OPTIC AND COPPER LINES.
B) COIL EXCESS EXISTING LINES IN THE EXISTING FIBER PULL BOXES. SPLICE IN NEW SIGNAL COMMUNICATION
STA. 189+82, PULL THE EXISTING LINES TO THE PULL BOXES AT STA. 187+81 AND STA. 193+79.
A) CUT THE EXISTING SIGNAL COMMUNICATION FIBER OPTIC AND COPPER LINES FROM THE EXISTING PULL BOX AT
2) THE PROPOSED WORK FOR THE SIGNAL COMMUNICATION FIBER OPTIC AND COPPER LINES:
BOXES.
LINES RUN WEST-EAST ALONG THE SOUTH SIDE OF CR 584 (WATERS AVE), THROUGH EXISTING CONCRETE PULL
1) THE EXISTING 24-CT AND 12-CT FIBER OPTIC SIGNAL COMMUNICATION LINES AND COPPER SIGNAL COMMUNICATION
NOTES:
PUBLIC WORKS ADMINISTRATION
1 EA
1 EA
635-2-13
633-2-31
633-3-11
633-3-12
633-3-141 EA
633-1-121
633-1-121
630-2-11
633-3-17
633-3-161 EA
1 EA
684-1-11 EA
633-2-3212 EA
635-2-121 EA (24"x36")
630-2-11
R/W LINE
R/W LINE
R/W LINE
R/W LINE
R/W LINE
R/W LINE
150 LF (12-CT)
65 LF (50 LF COIL, 12-CT)
50 LF (24-CT COIL)
£ SURVEY
¡ CONST.
FOR DIRECTIONAL BORE
SEE SIGNALIZATION PLAN
15 LF (1 RUN, (1) FOC)
4 EA
633-4-1
633-4-1
633-1-122
633-1-121
160 LF (COPPER COMMUNICATION)
633-4-1
633-1-122
633-1-420
633-2-31
630-2-11
633-4-1
633-1-121
450 LF (COPPER COMMUNICATION) 633-4-1
633-1-121
633-1-420
633-2-31
611-2-1
ITS DOCUMENTATION - INTERSECTION
611-1-1 0.10 MI
ITS DOCUMENTATION - PROJECT LENGTH
1 EA
1 EA 633-3-11
1 EA633-3-11
633-1-121 50 LF (12-CT COIL)
(1) COPPER, (1) SPARE)
450 LF (4 RUNS, (2) FOC,
(1) COPPER, (1) SPARE)
160 LF (4 RUNS, (2) FOC,
30 EA (COIL AND CAP ALL UNUSED FIBERS)
30 EA (COIL AND CAP ALL UNUSED FIBERS)
2 EA633-3-12
2 EA 633-3-12
) 30"x60"1 EA (
25 LF (COPPER COMMUNICATION COIL)
25 LF (COPPER COMMUNICATION COIL)
1200 LF*
633-1-122
633-1-121
633-1-122450 LF (24-CT)
450 LF (12-CT)
160 LF (12-CT)
633-1-122 160 LF (24-CT)
25 LF (12-CT COIL)
25 LF (24-CT COIL)
SEE SPLICING DETAIL SPL-4
SEE SPLICING DETAIL SPL-3
PROPOSED 30"x60" VAULT STA. 189+36
STA. 193+79
SEE SPLICING DETAIL SPL-2
EXIST. FIBER PULL BOX
50 LF (COPPER COMMUNICATION COIL)
633-6 226 DA
FIBER OPTIC CABLE LOCATOR
RIGHT OF ENTRY LINE
8/28/2025vserpekian P:\HCE1701\31-Waters at Florida Mining\CADD\69679026\signing\gswksp01.dgn12:12:38 PM
REVISIONS
DATE DESCRIPTION
T
F I
C I
C O
E E
T
E C
T R
O N
G I
T A
L
G N
A L
D
L E
G
A
ELEMENT ENGINEERING GROUP, LLC
P.E. LICENSE NUMBER 82646
VICKEN SERPEKIAN, P.E., P.T.O.E.
NUMBER
OF POSTS
NUMBER
OF POSTS
NUMBER
OF POSTS
NUMBER
OF POSTS
SPACE
SPACE
COPY
SPACE
COPY
SPACE
COPY
SPACE
COPY
COPY
SPACE
SPACE
COPY
SPACE
COPY
SPACE
COPY
SPACE
COPY
COPY
COPY
SPACE
COPY
SPACE
COPY
SPACE
COPY
SPACE
COPY
SPACESPACE
SPACE
COPY
SPACE
COPY
SPACE
COPY
SPACE
COPY
COPY
SPACE
COPY COPY
SPACE
SPACE
COPY
SPACE
COPY
SYMBOL(S) X Y WID HTANGLE
SIGN NAME STATION(S)
WIDTH
HEIGHT
PANEL
LEGEND
COLOR
RADII
WIDTH
BORDER
COLOR
NUMBER
SIGN
QTY
CLEARANCE COLUMN SIZE AVERAGE
LENGTH
Edge Of Lane
HEIGHT
PANEL
LEGEND
COLOR
RADII
WIDTH
BORDER
COLOR
HEIGHT
PANEL
LEGEND
COLOR
RADII
WIDTH
BORDER
COLOR
HEIGHT
PANEL
LEGEND
COLOR
RADII
WIDTH
BORDER
COLOR
FIXTURE SPACINGNO. OF LIGHT FIXTURES PHOTOMETRIC CURVE WATT VOLTAGE FIXTURE SPACINGNO. OF LIGHT FIXTURES PHOTOMETRIC CURVE WATT VOLTAGE
FIXTURE SPACINGNO. OF LIGHT FIXTURES PHOTOMETRIC CURVE WATT VOLTAGE FIXTURE SPACINGNO. OF LIGHT FIXTURES PHOTOMETRIC CURVE WATT VOLTAGE
T-12
GUIDE SIGN WORKSHEET
LEFT BLANK
INTENTIONALLY
THIS SPACE IS
LEFT BLANK
INTENTIONALLY
THIS SPACE IS
7.7" 74.6" 7.7"
7'-6"
5"
8"E
6"
6"D
5"
GS-1 1
7'-6" 1.25"
180+71
2'-6" 3.75"
White White
Green
7.7
F l
2.6 o
6.3 r
4.6 i
2.6 d
6.1
4.9
9.3 i
2.9 n
6.3 i
2.9 n
6.1 g
5 7.7
L
74.6
19.2
N
5.5
E
4.3
X
4.6
3.7
5.1
I
2.3
G
5.4
N
A
L
3.7 19.2
L
51.6
GS-2 1
7'-0" 1.25"
199+00
4'-0" 6"
White White
Green
7.3
F
6.1 l
3.1 o
5.9 r
4.4 i
3.1 d
5.8
7.6 i
3.6 n
6.4 i
3.6 n
5.8 g
4 7.4
L
69.3
16.2
N
5.5
E
4.3
X
4.6
3.7
5.1
I
2.3
G
5.4
N
A
L
3.7 16.2
L
51.6
6.5
A
7.5 n
5.8 d
5.8 e
5.8 r
3.8 s
5.3 o
5.9 n
5.9 o
5.4 a
5.8 d
4 6.5
L
10.2
S
5.1
E
4.6
C
5.3
O
5.6
N
5.5
4.1
5.1
I
2.3
G
5.4
N
A
L
3.7 10.2
L
63.7
6.5" 71" 6.5"
7'-0"
4"
6"EM
4.38"
6"D
3" 1.25"
3"
6"EM
4.38"
6"D
4"
PUBLIC WORKS ADMINISTRATION
601 E. KENNEDY BLVD.
8/28/2025vserpekian P:\HCE1701\31-Waters at Florida Mining\CADD\69679026\signals\gswksg01.dgn12:12:44 PM
REVISIONS
DATE DESCRIPTION
T
F I
C I
C O
E E
T
E C
T R
O N
G I
T A
L
G N
A L
D
L E
G
A
ELEMENT ENGINEERING GROUP, LLC
P.E. LICENSE NUMBER 82646
VICKEN SERPEKIAN, P.E., P.T.O.E.
NUMBER
OF POSTS
NUMBER
OF POSTS
NUMBER
OF POSTS
NUMBER
OF POSTS
SPACE
SPACE
COPY
SPACE
COPY
SPACE
COPY
SPACE
COPY
COPY
SPACE
SPACE
COPY
SPACE
COPY
SPACE
COPY
SPACE
COPY
COPY
COPY
SPACE
COPY
SPACE
COPY
SPACE
COPY
SPACE
COPY
SPACESPACE
SPACE
COPY
SPACE
COPY
SPACE
COPY
SPACE
COPY
COPY
SPACE
COPY COPY
SPACE
SPACE
COPY
SPACE
COPY
HEIGHT
PANEL
LEGEND
COLOR
RADII
WIDTH
BORDER
COLOR
HEIGHT
PANEL
LEGEND
COLOR
RADII
WIDTH
BORDER
COLOR
HEIGHT
PANEL
LEGEND
COLOR
RADII
WIDTH
BORDER
COLOR
HEIGHT
PANEL
LEGEND
COLOR
RADII
WIDTH
BORDER
COLOR
FIXTURE SPACINGNO. OF LIGHT FIXTURES PHOTOMETRIC CURVE WATT VOLTAGE FIXTURE SPACINGNO. OF LIGHT FIXTURES PHOTOMETRIC CURVE WATT VOLTAGE
FIXTURE SPACINGNO. OF LIGHT FIXTURES PHOTOMETRIC CURVE WATT VOLTAGE FIXTURE SPACINGNO. OF LIGHT FIXTURES PHOTOMETRIC CURVE WATT VOLTAGE
GUIDE SIGN WORKSHEET
5" 98" 5"
9'-0"
3.25"
8"E
3.5"
6"E
3.25"
3.25"
8"
3.5"
6"E
3.25"
5" 98" 5"
9'-0"
3.25"
8"
3.5"
6"E
3.25"
3.25"
8"E
3.5"
6"E
3.25"
SIGN Z 1
9'-0" 0" none
2'-0" 0"
White White
Green
F l
2.6 o
6.3 r
4.6 i
2.6 d
6.1
9.3 i
2.9 n
6.3 i
2.9 n
6.1 g
5 28.4
L
74.6
31.1
B
6.1
L
V
6.5
D
4.9 54.5
L
22.4
79.4
5.5
6.8
6.2
5 5
L
23.6
AR_Type D 91 12.7 8 12270
SIGN Y 1
9'-0" 0" none
2'-0" 0"
White White
Green
28.4
F l
2.6 o
6.3 r
4.6 i
2.6 d
6.1
9.3 i
2.9 n
6.3 i
2.9 n
6.1 g
5 5
L
74.6
5.5
6.8
6.2
5 79.4
L
23.6
52.6
B
6.1
L
V
6.5
D
4.9 33
L
22.4
AR_Type D 5 12.7 8 1290
T-13
5" 80" 5"
7'-6"
14.7"
6"E
3.3"
3.25"
8"EM
3.5"
6"E
3.25"
14.75"
6"E
3.25"
5" 80" 5"
7'-6"
14.8"
6"E
3.2"
3.25"
8"EM
3.5"
6"E
3.25"
14.75"
6"E
3.25"
SIGN W 1
7'-6" 0" none
2'-0" 0"
White White
Green
24.3
W
9.7 a
7.7 t e
7.8 r s
5.3 24.3
L
41.4
5.5
6.8
6.2
5 61.4
L
23.6
36.2
A
6.6
V
6.5
E
4.5 36.1
L
17.6
62.1
5.7
5.9
6.2
5 5
L
22.9
SIGN X 1
7'-6" 0" none
2'-0" 0"
White White
Green
24.3
W
9.7 a
7.7 t e
7.8 r s
5.3 24.3
L
41.4
5.7
5.9
6.2
5 62.1
L
22.9
36.2
A
6.6
V
6.5
E
4.5 36.1
L
17.6
61.4
5.5
6.8
6.2
5 5
23.6
8/28/2025vserpekian P:\HCE1701\31-Waters at Florida Mining\CADD\69679026\signals\RDXSSG01.dgn12:12:49 PM
REVISIONS
DATE DESCRIPTION
T
F I
C I
C O
E E
T
E C
T R
O N
G I
T A
L
G N
A L
D
L E
G
A
ELEMENT ENGINEERING GROUP, LLC
P.E. LICENSE NUMBER 82646
VICKEN SERPEKIAN, P.E., P.T.O.E.
.8
CRIT. EL = 27.1
.0
.4
.6
.0
.6
£ SURVEY
15 15
.0
£ SURVEY
3040 20 10 0 10 20 3070 60 508090100110
T-14
SIGNALIZATION
CROSS SECTION
EXIST. GROUND
4" BT, Vvh108, STA. 189+55.04
EL 27.60
MA 1
4" CI FM, HCWRD
(3X) 4", BFOT Vvh107, STA. 189+51.34
VERT. 1" = 5'
HORIZ. 1" = 10'
SCALE:
WATERS AVE SECTION
STA. 189+54, 81.3' LT.
POLE 1/ARM 1
PUBLIC WORKS ADMINISTRATION
601 E. KENNEDY BLVD.
8/28/2025vserpekian P:\HCE1701\31-Waters at Florida Mining\CADD\69679026\signals\RDXSSG01.dgn12:12:49 PM
REVISIONS
DATE DESCRIPTION
T
F I
C I
C O
E E
T
E C
T R
O N
G I
T A
L
G N
A L
D
L E
G
A
ELEMENT ENGINEERING GROUP, LLC
P.E. LICENSE NUMBER 82646
VICKEN SERPEKIAN, P.E., P.T.O.E.
.7
CRIT. EL = 26.5
.0
.5
1'
.9
R
W
L I N
E
� CONST.
.0
� CONST.
3040 2070 60 50 10 0 10 20 30 40 50 60 70
T-15
2" BTV, Vvh102, STA. 189+46.28
4" GM, Vvh106, STA. 189+50.24
4" BT, Vvh108, STA. 189+55.04
EXIST. GROUND
(2X) 4" BT, Vvh103, STA. 189+47.44
(2X) 2" BTV, Vvh105, STA. 189+49.32
(3X) 4" BT, Vvh107, STA. 189+51.34
4" PVC & 1" DB BT, Vvh104, STA. 189+48.54
(2X) 4" PVC BT, FTR
.9
EL 27.60
MA 1
.0
1" DB BT, Vvh101, STA. 189+44.40
4" CI FM, Vvh 123, STA. 189+58.10
18" RCP SD
LOWER BY 6"
BRACKET ADJUSTED
BFOT, FTR
VERT. 1" = 5'
HORIZ. 1" = 10'
SCALE:
FLORIDA MINING BLVD SECTION
STA. 10+81, 28.7' LT.
POLE 1/ARM 2
PUBLIC WORKS ADMINISTRATION
601 E. KENNEDY BLVD.
8/28/2025vserpekian P:\HCE1701\31-Waters at Florida Mining\CADD\69679026\signals\RDXSSG01.dgn12:12:49 PM
REVISIONS
DATE DESCRIPTION
T
F I
C I
C O
E E
T
E C
T R
O N
G I
T A
L
G N
A L
D
L E
G
A
ELEMENT ENGINEERING GROUP, LLC
P.E. LICENSE NUMBER 82646
VICKEN SERPEKIAN, P.E., P.T.O.E.
R
W
L I N
E
.8
.6
CRIT. EL = 27.3
.0
.7
.5
.8
£ SURVEY
0 10 20 30 40 50 60 70 80 9010203040 100
£ SURVEY
(3X) 1.5" BFOC, Vvh121, STA. 190+05.09
(2X) 1.25" BFOC, Vvh118, STA. 190+05.51 4" STEEL UNKNOWN, Vvh116, STA. 190+05.46
6" GM, Vvh115, STA. 190+02.46
(2X) 3" PVC FOC, Vvh117, STA. 190+05.48
4" PVC UNKNOWN, Vvh113, STA. 190+02.59
2" PVC UNKNOWN, Vvh114, STA. 190+02.50
T-16
BFOC, Vvh120, STA. 190+05.25
BFOC, Vvh119, STA. 190+05.47 BFOC, Vvh112, STA. 190+04.59
EL 26.92
MA 2
(3X) 1.25" HDPE BFOC, ZAYO
(12X) 1.25" & (8X) 1.5" BFOC, CENTURYLINK
LOWER BY 6"
BRACKET ADJUSTED
(8X) 1.25" BFOC, MCI
20" DIP WM(B)
1.
R I G
E
N T
R Y
L I N
E
VERT. 1" = 5'
HORIZ. 1" = 10'
SCALE:
WATERS AVE SECTION
STA. 190+11, 51.0' RT.
POLE 2/ARM 1
PUBLIC WORKS ADMINISTRATION
601 E. KENNEDY BLVD.
8/28/2025vserpekian P:\HCE1701\31-Waters at Florida Mining\CADD\69679026\signals\RDXSSG01.dgn12:12:49 PM
REVISIONS
DATE DESCRIPTION
T
F I
C I
C O
E E
T
E C
T R
O N
G I
T A
L
G N
A L
D
L E
G
A
ELEMENT ENGINEERING GROUP, LLC
P.E. LICENSE NUMBER 82646
VICKEN SERPEKIAN, P.E., P.T.O.E.
.9
.0
1.
.6
.6
� CONST.
CRIT. EL = 26.4
0 10 20 30 40 50 60 7010203040506070
� CONST.
T-17
EL 26.92
MA 2
LOWER BY 6"
BRACKET ADJUSTED
LOWER BY 6"
BRACKET ADJUSTED
BFOC, Vvh119, STA. 190+05.47
(3X) 1.5" BFOC, Vvh121, STA. 190+05.09
BFOC, Vvh120, STA. 190+05.25
(2X) 1.25" BFOC, Vvh118, STA. 190+05.51
4" STEEL UNKNOWN, Vvh116, STA. 190+05.46
VERT. 1" = 5'
HORIZ. 1" = 10'
SCALE:
FLORIDA MINING BLVD SECTION
STA. 9+49, 28.2' RT.
POLE 2/ARM 2
PUBLIC WORKS ADMINISTRATION
601 E. KENNEDY BLVD.
8/28/2025vserpekian P:\HCE1701\31-Waters at Florida Mining\CADD\69679026\signals\SPDTSG03.DGN12:13:53 PM
REVISIONS
DATE DESCRIPTION
T
F I
C I
C O
E E
T
E C
T R
O N
G I
T A
L
G N
A L
D
L E
G
A
ELEMENT ENGINEERING GROUP, LLC
P.E. LICENSE NUMBER 82646
VICKEN SERPEKIAN, P.E., P.T.O.E.
PUBLIC WORKS ADMINISTRATION
GAS
N
N
N
CR 584 (WATERS AVE)
CR 584 (WATERS AVE)
CR 584 (WATERS AVE)
T-18
PEDESTRIAN SIGNAL DETAILS
MINING AT CR 584 (WATERS AVE)
NORTHWEST QUADRANT OF FLORIDA
MINING AT CR 584 (WATERS AVE)
NORTHEAST QUADRANT OF FLORIDA
MINING AT CR 584 (WATERS AVE)
SOUTHWEST QUADRANT OF FLORIDA
PEDESTRIAN SYMBOLS
POLE WITH BUTTON
PROPOSED PEDESTRIAN SIGNAL
SIGNAL POLES (2% MAX)
PROPOSED PEDESTRIAN
AREA ADJACENT TO
30"X48" PEDESTRIAN LANDING
8/28/2025vserpekian P:\HCE1701\31-Waters at Florida Mining\CADD\69679026\signals\SPDTSG03.DGN12:13:53 PM
REVISIONS
DATE DESCRIPTION
T
F I
C I
C O
E E
T
E C
T R
O N
G I
T A
L
G N
A L
D
L E
G
A
ELEMENT ENGINEERING GROUP, LLC
P.E. LICENSE NUMBER 82646
VICKEN SERPEKIAN, P.E., P.T.O.E.
PUBLIC WORKS ADMINISTRATION
N
CR 584 (WATERS AVE)
T-19
PEDESTRIAN SIGNAL DETAILS
MINING AT CR 584 (WATERS AVE)
SOUTHEAST QUADRANT OF FLORIDA
PEDESTRIAN SYMBOLS
POLE WITH BUTTON
PROPOSED PEDESTRIAN SIGNAL
SIGNAL POLES (2% MAX)
PROPOSED PEDESTRIAN
AREA ADJACENT TO
30"X48" PEDESTRIAN LANDING
8/28/2025vserpekian P:\HCE1701\31-Waters at Florida Mining\CADD\69679026\signals\MSSGSG01.DGN12:13:58 PM
REVISIONS
DATE DESCRIPTION
T
F I
C I
C O
E E
T
E C
T R
O N
G I
T A
L
G N
A L
D
L E
G
A
ELEMENT ENGINEERING GROUP, LLC
P.E. LICENSE NUMBER 82646
ROADWAY UNDER SIGNALS)
(HIGHEST POINT OF
CRITICAL ROAD ELEVATION
ELEVATION.
TOP OF FOUNDATION
** GROUT PAD
NO.
ID.
STRUCT.
NO.
ID.
POLE
NO.
SHEET
BY STA.
LOCATION
EL.
ROAD
CRITICAL
GROUND
OUT OF
FOUNDATION
ELEVATION
FOUNDATION
TOP OF
NO.
ARM
RDWY
SIGNAL DATA
DISTANCE FROM POLE
V/H
SIGNAL
Y/N
PLATES
BACK
Y/N
SIGNAL
PED.
1 * 2 * 3 * 4 * 5 * 6 * 7 * 8 LENGTH
ARM
TOTAL
M.H.
ARM
90/270
DUAL ARMS
/ BETWEEN
SIGN DATA
DISTANCE FROM POLE / HEIGHT AND WIDTH OF SIGN
A H1 W1 B H2 W2 C H3 W3 D H4 W4
G
Y
R
G
Y
R
G
Y
R
(ARM M.H.)
HEIGHT
MOUNTING
ARM
TOP OF FOUNDATION ELEVATION
EB WB
POLE FOUNDATION DETAIL
SPECIAL NOTES:
NB SB
SIGN A
FROM POLE
UNIT DISTANCE
DETECTION
MICROWAVE
W1
H1
TOTAL ARM LENGTH
Y NV 31
9.0'2.0' 2.5'3.0'
NB SB EB WB
FROM POLE
UNIT DISTANCE
PREEMPTION
EMERGENCY
1 Y NV2 9.0'2.0'
189+54, 81.3' LT.
190+11, 51.0' RT.
78'
60'
50'
50'
33.5 39.0 44.5 55.5 66.5
34.0 39.0 44.0
1 3 3 4
3 1 3
17.0 328.0 33.5 1 39.0 3 50.5 4
36.0 3 42.0 1 48.0 3
15.0'
6.5' 2.0'
2.0'
63.5'
47.5' 3.0' 2.5'
61.5'8.0'
0.0' 49.0'
47.0'
44.5'
2 10.0'
27.1
27.3
0.50
BC
SIGN B
S I G
N
C
W2
H2 W3
H3
R
23567
20'
21'
21'
7.5'
7.5'
50.0 1
48.0 1
122.5
30.0 1
BACKPLATES.
BACKPLATES. ALL OTHER SIGNAL HEADS REQUIRE RETROREFLECTIVE
D. POWER OUTAGE EMERGENCY BEACON SIGNAL HEADS SHALL NOT HAVE
C. FIELD VERIFY ALL ELEVATIONS LISTED HEREIN.
ITSELF AND THE POLE SHAFT.
SHALL BE OF SUFFICIENT SIZE SO THAT THERE IS NO GAP BETWEEN
BY A MINIMUM OF TWO (2) THREADED FASTENERS. THE BOLT COVERS
SHALL BE GALVANIZED STEEL OR CAST ALUMINUM AND SHALL BE SECURED
B. ANCHOR BOLT COVERS (ORNAMENTAL, NON-ORNAMENTAL, AND/OR PAINTED)
POLE IDENTIFICATION NUMBER SHOWN ON THE PLANS.
ONE INCH (1") HIGH ENGRAVED OR IMPRESSED MARK WHICH BEARS THE
A. EACH POLE AND MAST ARM SHALL BE IDENTIFIED WITH A PERMANENT
DIRECTION FROM ARM NO. 1.
TO BE MEASURED IN A COUNTER CLOCKWISE
ARM NO. 2 - DOUBLE ARM POLE ORIENTATION
LONGEST ARM FOR DOUBLE ARM POLE.
ARM NO. 1 - SINGLE ARM POLE OR
Y NV
Y NV
27.60
26.92
T-9
T-9
26.5
26.4
20'
T-20
MAST ARM TABULATION
10.0'
T-9
T-9 189+54, 81.3' LT.
190+11, 51.0' RT. 27.3
26.4
26.5
27.1 0.5
0.0 26.92
27.60 1
2 V
V
V
V Y
Y
Y
Y N
N
N
N 33.5
34.0
17.0
30.0 1
3 39.0 44.5
39.0 44.0
1 3
1 3
328.0
36.0 3 42.0 1
122.5
55.5 71.03 4
33.5 1 39.0 3 55.5 4
48.0 3
50.0 1
48.0 1
21'50'
60' 21'
50' 20'
78' 20' 90
90 10.0'
10.0'
6.5'
15.0' 9.0'2.0' 2.5'3.0'
9.0'2.0'
2.0'
2.0'
68.0'
52.5' 3.0' 2.5'
7.5'
7.5'
61.5'8.0'
0.0' 49.0'
47.0'
44.5'
**1
**2
* DENOTES NUMBER OF SECTIONS IN SIGNAL HEAD ASSEMBLY
** PROPOSED FUTURE CONDITIONS
R
DETECTION UNIT
MICROWAVE
G
Y
R Y
R
G
FY
A
321.5
321.5
30.0
30.0
0.0
PUBLIC WORKS ADMINISTRATION
8/28/2025vserpekian P:\HCE1701\31-Waters at Florida Mining\CADD\69679026\signals\PLDTSG01.dgn12:14:00 PM
REVISIONS
DATE DESCRIPTION
T
F I
C I
C O
E E
T
E C
T R
O N
G I
T A
L
G N
A L
D
L E
G
A
ELEMENT ENGINEERING GROUP, LLC
P.E. LICENSE NUMBER 82646
T-21 MAST ARM SCHEDULE
STANDARD MAST ARM ASSEMBLIES DATA TABLE
NUMBERS
ID
STRUCTURE
NUMBERS
ASSEMBLY
FIRST ARM SECOND ARM
(deg)
UF
(deg)
LL
POLE SPECIAL DRILLED SHAFT (3)
TYPE
ARM
(ft.)
FAA
(1)
(in.)
FBA
(1)
TYPE
ARM
(ft.)
FAA
(1)
(in.)
FBA
(1)
TYPE
POLE
(ft.)
UAA
(2)
(ft.)
UB
(in.)
UCA
(2)
(ft.)
DA
(ft.)
DB
RA RB RC
(in.)
RD
A78/D/H - - A50/D/H - - 90 - P7/D -
2 A60/D - - A50/D - - 90 - P4/D -
29 5 11 18 12 8
(SEE SHEET T-22)
23 20
24 21
NOTE: MAST ARM STRUCTURES HAVE BEEN DESIGNED AND PROCURED UNDER CIP 69645132. SHOWN FOR SPECIAL DRILLED SHAFT INFORMATION ONLY.
* SEE FOUNDATION NOTE 2
1*
MAST ARM 1-2 LOCATION PARAMETERS
DEPTH 0-4 4-8 8-23.5 23.5-25
CLASSIFICATION SP-SM SP-SM SC SC
WEIGHT (SUBMERGED) 42.6 47.6 42.6 47.6
FRICTION ANGLE 29 30 29 30
ASSUMED DESIGN WATER TABLE IS 0 FT. BELOW SURFACE
NOTES :
1. If an entry appears in column FAA, a shorter arm is required. This is obtained by removing length from the arm tip and the arm length shortened from FA to FAA. SAA Similar.
2. If an entry appears in column UAA, a shorter pole is required. This is obtained by removing length from the pole tip and the pole height shortened from UA to UAA.
3. Pole types P2 and larger require a minimum 4.5 foot diameter drilled shaft. Pole types P5 and larger require a minimum
5.0 foot diameter drilled shaft.
4. Work this sheet with the Signal Designer’s “Mast Arm Tabulation”. See “Mast Arm Tabulation” for special instructions that include non-standard Handhole location, paint color, terminal compartment requirement, and pedestrian features.
5. Work with Standard Plans Index 649-030 and 649-031.
6. Design Wind Speed = 150 mph
FOUNDATION NOTES :
1. Design based on Borings sealed by Kristina LaCava, P.E., MC Squared, Inc.
MAST ARM 1-1 LOCATION PARAMETERS
DEPTH 0-6 6-13.5 13.5-23.5 23.5-25
CLASSIFICATION SP-SM SP-SM, SC SP-SM, SC SP
WEIGHT (SUBMERGED) 42.6 47.6 42.6 47.6
FRICTION ANGLE 29 30 29 30
ASSUMED DESIGN WATER TABLE IS 0 FT. BELOW SURFACE
2. Assumptions and Values used in design:
3. Subsurface materials encountered during site exploration may become unstable and cave in during excavation of the drilled shaft. A temporary casing will be necessary to stabilize the near surface soils.
PUBLIC WORKS ADMINISTRATION
8/28/2025vserpekian P:\HCE1701\31-Waters at Florida Mining\CADD\69679026\signals\SPDTSG01.dgn12:14:04 PM
REVISIONS
DATE DESCRIPTION
T
F I
C I
C O
E E
T
E C
T R
O N
G I
T A
L
G N
A L
D
L E
G
A
ELEMENT ENGINEERING GROUP, LLC
P.E. LICENSE NUMBER 82646
VICKEN SERPEKIAN, P.E., P.T.O.E.
L O
N G I T
U D I N
A
TRANSVERSE
SPREAD FOOTER DETAILS
T-22
(TYPICAL)
3" COVER (MIN.)
EQUALLY SPACED
12 - #6 LONGITUDINAL BARS
EQUALLY SPACED
6 - #6 LONGITUDINAL BARS
EQUALLY SPACED
12 - #6 TRANSVERSE BARS
EQUALLY SPACED
19 - #11 BARS
¡ FOOTING
¡ POLE
6'-6"
2'-7"
6"
SEE NOTE 4
ANCHOR BOLTS
EQUALLY SPACED
7 - #6 LONGITUDINAL BARS
(MIN.)
3" COVER
SEE NOTE 4
ANCHOR BOLTS
(SEE MAST ARM TABULATION SHEET)
FOUNDATION EL.
PLAN VIEW
(CONDUIT NOT SHOWN)
SECTION VIEW
12 - #6 BARS EQUALLY SPACED (BOT.)
12 - #6 BARS EQUALLY SPACED (TOP)
13'-0"
12" LAP
PEDESTAL
� 4 '-6"
B
A R
C
IR
C L E
'-1 0"
6'-6"
2'-3"
B
A R
S
E
Q U
A L L
Y
S
P A
C E
D
(B
O T
B
A R
S
E
Q U
A L L
Y
S
P A
C E
D
(T
O P
MAST ARM 2 SPREAD FOOTING
#6 BARS @ 12"
DIRECTION)
SIDEWALK SLOPE
0.02 (MATCH
FOR DETAILS
SEE STANDARD INDEX 520-001
TYPE F CURB AND GUTTER SHAPE
1'
2'
ARM POLE
¡ MAST
ARM 1 DIRECTION
ARM 2 DIRECTION
(TYPICAL)
4" COVER (MIN.)
7. SPREAD FOOTINGS SHALL BE CAST IN PLACE.
OF THE CONDUIT SHALL BE VERIFIED PRIOR TO CONSTRUCTION.
CONDUIT SHALL BE SEALED IN ACCORDANCE WITH SUBARTICLE 630-3.4. LOCATION
CONDUIT SHALL BE MADE USING A RADIUS NOT LESS THAN 11 INCHES. END OF
6. ALL CONDUIT SHOULD BE RIGID GALVANIZED STEEL OR SCHEDULE 40 PVC. BENDS IN
OF FOOTING.
INCHES CONCRETE COVER AT BOTTOM2
15. ANCHOR BOLTS ARE TO HAVE A MINIMUM 4
REGISTERED ENGINEER.
THE DRAWING AND CALCULATIONS SHALL BE SIGNED AND SEALED BY A QUALIFIED FLORIDA
THE CONTRACTOR SHALL SUBMIT SHOP DRAWINGS WITH CALCULATIONS FOR THE ANCHOR BOLTS.
TRANSMIT THE MAST ARM LOAD TO THE FOOTER AND THAT FIT THE REINFORCING CAGE.
4. THE CONTRACTOR IS RESPONSIBLE FOR PROVIDING ANCHOR BOLTS THAT EFFECTIVELY
INSTALLATION UNLESS NOTED OTHERWISE.
3. THE COST OF THE FOOTING IS INCLUDED IN THE PAY ITEM NUMBER FOR THE MAST ARM
FOR BACKFILL, COMPACTION, AND DENSITY MATERIAL REQUIREMENTS.
SOIL BELOW FOOTING IS TO HAVE A MINIMUM BEARING CAPACITY OF 2.75 kip/sq ft.
UNIT WEIGHT = 110 LBS./CU.FT. (ASSUMED DRY)
FRICTION ANGLE = 30 DEGREES (30°)
CLASSIFICATION = COHESIONLESS (FINE SAND)
SOIL CRITERIA:
2. THE FOUNDATIONS FOR MAST ARM POLES ARE DESIGNED BASED UPON THE FOLLOWING
SEE NOTE 4. C. ANCHOR BOLTS:
AT 28 DAYS FOR ALL ENVIRONMENTAL CLASSIFICATIONS.
B. CONCRETE: CLASS IV, 2,500PSI (F'C) MINIMUM COMPRESSIVE STRENGTH
REINFORCEMENT. BAR REINFORCEMENT SHALL BE ASTM A615, GRADE 60.
A. REINFORCING STEEL: REINFORCEMENT SHALL BE DEFORMED BAR
1. FOUNDATION MATERIALS:
MAST ARM SPREAD FOOTER FOUNDATION NOTES:
8/28/2025vserpekian P:\HCE1701\31-Waters at Florida Mining\CADD\69679026\signals\SPDTSG02.dgn12:14:06 PM
REVISIONS
DATE DESCRIPTION
T
F I
C I
C O
E E
T
E C
T R
O N
G I
T A
L
G N
A L
D
L E
G
A
ELEMENT ENGINEERING GROUP, LLC
P.E. LICENSE NUMBER 82646
VICKEN SERPEKIAN, P.E., P.T.O.E.
PRECAST OPTION FOOTING NOTES:
DESIGN METHODS:
CONCRETE:
REINFORCING STEEL:
CONCRETE COVER:
LOAD RESISTANCE FACTOR DESIGN.
THE AREA OF THE REINFORCEMENT SHOWN IN THE DRAWING.
5. WHEN WELDED WIRE FABRIC IS USED, THE AREA MUST BE AT LEAST EQUAL TO
CASTING DATE AND IDENTIFICATION LETTERS AND NUMBERS.
4. MARKING: EACH PRECAST CONCRETE FOOTING SHALL BE MARKED SHOWING
FROM THE END.
SUPPORTED NO CLOSER THAN 6 INCHES AND NO FURTHER THAN 18 INCHES
STORED ON ADEQUATE DUNNAGE. THE PRECAST CONCRETE FOOTING MUST BE
3. STORAGE AND TRANSPORTATION: ALL PRECAST CONCRETE FOOTINGS MUST…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .