2-Florida Trench Safety Act, Certification and Disclosure Statement.pdf.pdf

PDF 17 KB Posted

Attached to
CR 584 (Waters Ave) at Florida Mining Blvd. Intersection Improvements
Solicitation number
IFB-26-00287
Issued by
Hillsborough County, Florida

About this file

This is a Florida Trench Safety Act Certification and Disclosure Statement document required by Hillsborough County, Florida for the CR 584 (Waters Ave) at Florida Mining Boulevard Intersection Improvements project. The document establishes mandatory compliance requirements for bidders undertaking excavation and trenching work on this traffic signal installation project. Bidders must acknowledge and commit to compliance with the Florida Trench Safety Act and the Federal excavation safety standards outlined in 29 CFR Part 1926.650, Subpart P, along with any supplemental shoring requirements established by the State of Florida or Hillsborough County. The contractor is solely responsible for selecting geotechnical data and designing an appropriate trench safety system, considering information available from the County, their own sources, and all other relevant project information.

Bidders must disclose the cost of compliance with trench safety requirements by itemizing each trench safety measure with associated quantities, unit costs, and extended costs. The total disclosed amount must match the cost identified in the contract requirement titled "Florida Trench Safety Act." The County's acceptance of any bid containing this certification does not constitute an evaluation or determination that the disclosed costs are adequate for compliance, nor does it relieve the contractor of its sole responsibility to comply with all applicable trench safety standards. Any additional costs necessary to achieve compliance beyond the disclosed amount must be expended by the contractor at no additional cost to the County, except as otherwise provided in the contract documents.

View the file

Other files

File Type Posted
14-Subcontractor Letter of Intent .pdf PDF
45-IFB-26-00287 Contract Terms and Conditions.pdf PDF
27-Attachment C - URS - TECO Peoples Gas-Signed.pdf PDF
19-Attachment C - URS - CrownCastle-Signed.pdf PDF
10-Direct Deposit Authorization Form 5.15.2025.pdf.pdf PDF
38-IFB-26-00287 Plans - Waters-FL Mining SS UTV1.pdf PDF
41-IFB-26-00287 Supplemental Specifications.pdf PDF
4-Application for Payment.pdf.pdf PDF
24-Attachment C - URS - NC - Summit No Conflict Letter.pdf PDF
12-Contractors Affidavit for Payment of Debts and Claims 02.18.2026.pdf PDF
16-Attachment B - GEO - Rpt Rev1 SS.pdf PDF
35-Payment Bond.pdf PDF
5-Subcontractors Statement of Satisfaction.pdf.pdf PDF
36-IFB-26-00287 Plans - ROADWAY.pdf PDF
23-Attachment C - URS - NC - Spectrum No Conflict.pdf PDF
15-Attachment A - Construction Sign 2026.pdf PDF
8-Insurance Certificate.doc.doc DOC document
26-Attachment C - URS - TCA- URS-Signed.pdf PDF
34-Performance Bond.pdf PDF
25-Attachment C - URS - Tampa Electric Signed.pdf PDF
42-Agreement - Construction - Stand Alone.pdf PDF
37-IFB-26-00287 Plans - SIGNALIZATION.pdf PDF
3-Allowance Authorization Release Form.pdf.pdf PDF
21-Attachment C - URS - FTR Signed.pdf PDF
1-Drug Free Workplace Form.doc.doc DOC document
33-Bid Bond.doc DOC document
20-Attachment C - URS - FIBERLIGHT -Signed.pdf PDF
28-Attachment C - URS - UNITI FIBER Signed.pdf PDF
17-Attachment C - URS - CenturyLink Signed.pdf PDF
9-Substitute W9 Form.pdf.pdf PDF
22-Attachment C - URS - MCI-Signed.pdf PDF
6-Consent of Surety to Final Payment.pdf.pdf PDF
43-IFB-26-00287 Insurance Requirements.pdf PDF
13-AFFIDAVIT OF COMPLIANCE - Denying Doing Business with a Foreign Country of Concern 02.26.2026.docx DOCX document
39-IFB-26-00287 Plans - Waters-FL Mining SS UTV2.pdf PDF
31-Attachment D - Permits - Waters Ave. at Florida Mining Blvd.exemption.pdf PDF
30-Attachment D - Permits - SWFWMD Permit Withdrawn.pdf PDF
32-Attachment E - Drainage-Memo.pdf PDF
18-Attachment C - URS - COTW Signed.pdf PDF
44-SBE Goal Participation SBE-1 Form Tutorial (SBE Division v3).mp4 MP4 file
7-Change Order Form.pdf.pdf PDF
40-IFB-26-00287 Project Map.pdf PDF
11-SBE Subcontractors Material Suppliers List SBE-1 Form.pdf PDF
29-Attachment C - URS - Utility Certification Letter 10.8.25.pdf PDF
Show all 44

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

HILLSBOROUGH COUNTY, FLORIDA

FLORIDA TRENCH SAFETY ACT

CERTIFICATION AND DISCLOSURE STATEMENT (MANDATORY)

The undersigned acknowledges the requirements of the Florida Trench Safety Act and hereby certifies that the undersigned is an authorized representative of the bidder and in that capacity commits the bidder to the following in the performance of the work in the event that the subject contract is awarded to and executed by said bidder.

1. The bidder acknowledges the Florida Trench Safety Act and the requirements established herein.

2. The bidder further acknowledges that the aforementioned Act established the Federal excavation safety standards set forth at 29

CFR Part 1926.650, Subpart P as the interim State standard until such time as the State of Florida, through its Department of Labor and Employment Security, or any successor agency, adopts, updates or reviews said interim standard. This State of Florida standard may be supplemented by special shoring requirements established by the State of Florida or any of its political subdivisions.

3. The bidder, as Contractor, shall comply with all applicable excavation/trench safety standards.

4. The Contractor shall consider the geotechnical information available from the County, its own sources and all other relevant information in its design of the trench safety system it will employ on the subject project. The Contractor acknowledges that it is solely responsible for the selection of the data on which it relies in designing said safety system, as well as for the system itself.

5. The amount the bidder has set forth in the requirement titled “Florida Trench Safety Act” includes the following excavation/trench safety measures and the linear feet of trench excavated under each safety measure. These units, cost and the unit prices inferred shall be disclosed solely for the purpose of compliance with the procedural requirements of the aforementioned Act. No adjustment to the Contract Time or Price shall be made for any difference in the number of linear feet of trench excavation, except as may otherwise be provided in these Contract Documents.

Trench Safety Measure

(Description) Unit

(QTY)

Unit of

Measure

(LF, SY)

Unit Cost Extended Cost

A. _____________________ __________ __________ $___________ $___________

B. _____________________ __________ __________ $___________ $___________

C. _____________________ __________ __________ $___________ $___________

D. _____________________ __________ __________ $___________ $___________

TOTAL $___________

Total above must be identical to cost shown in the requirement titled “Florida Trench Safety Act”. (Use additional blank sheets to further itemize if more room is required.)

6. This amount disclosed as the cost of compliance with the applicable trench safety requirement does not constitute the extent of the

Contractor's obligation to comply with said standards. Contractor shall expend additional sums, at no additional cost to the County (except as may otherwise be provided), which are necessary to so comply.

7. Acceptance of the bid to which this certification and disclosure applies in no way represents that the County or its representatives has evaluated and thereby determined that the above costs are adequate to comply with the applicable trench safety requirements nor does it in any way relieve the bidder, as Contractor, of its sole responsibility to comply with the applicable trench safety requirements.

(Authorized Signature)

(Typed name of firm, corporation, business or individual)

(Date)

File details come from the government source that posted it. Updated .