R4-A703.pdf
PDF 210 KB Posted
- Solicitation number
- 36E77620R0050
About this file
This document provides details on a federal contract opportunity to renovate mental health wards at the Minneapolis VA Medical Center. The Department of Veterans Affairs seeks to award a firm-fixed-price contract to furnish all labor, materials, tools and equipment for the renovation of Mental Health Wards 1L, 1H and 1K. The scope of work includes general construction, demolition, structural, mechanical, plumbing and electrical work, as well as low voltage, equipment, and all work necessary for the renovation. The solicitation will be issued as a Request for Proposal and advertised as a total Service-Disabled Veteran-Owned Small Business set-aside, with offers from other than SDVOSBs not being considered. The applicable NAICS code is 236220 with a size standard of $39.5 million. The period of performance is approximately 790 calendar days from notice to proceed, and the estimated magnitude of construction is between $10-20 million. The solicitation is expected to be issued on February 4, 2020.
View the file
Other files
Show all 44
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SEE PLAN
VARIES
S E
E P
LA
N
V A
R
IE
S
WALL - SEE PLAN
FOR TYPE
SEALANT - EA. SIDE
& ALL AROUND - TYP.
HOLLOW METAL
FRAME
4" 2"
WALL - SEE PLAN
FOR TYPE
ADJACENT WALL
WHERE OCCURS
HOLLOW METAL
FRAME
SEALANT - EA. SIDE
ALL AROUND - TYP.
H.M. HEAD DETAIL H.M. JAMB DETAIL
SOFFIT NOT TYP. ON
ALL HM DOOR FRAMES.
- REFER TO HARDWARE
SET
EXISTING VAPOR BARRIER - OVERLAP
NEW VAPOR BARRIER OLD MINIMUM 6"
AND SEAL W/ TAPE
FILL ALL VOIDS W/
BATT INSULATION
NEW GWB SOFFIT
WINDOW CLIP, SS FASTENERS
AND NEWPRENE SHIMS BY
WINDOW MANUFACTURER
BACKER ROD & SEALANT,
WEEP TUBES @ 18" O.C.
EXISTING PRECAST
WINDOW LINTEL
EXISTING STEEL CLIP
ANGLES
EXISTING BATT INSULATION
LEVEL 1
840'-4"
BACKER ROD & SEALANT,
BOTH SIDES
EXISTING CONC. FASTENER - PER MANUF.
INSTRUCTIONS
ALUM. WINDOW FRAME
GLAZING
FLASHING
ALUM. WINDOW FRAME
BACKER ROD & SEALANT,
NEOPRENE BLOCKING
EXISTING PRECAST
WINDOW LINTEL
EXISTING STEEL CLIP
ANGLES
WINDOW CLIP, SS
FASTENERS AND
NEOPRENE SHIMS BY
WINDOW MANUF.
FACE OF BRICK
BEYOND
NEW WALL ASSEMBLY,
SEE PLAN
LEVEL 1
840'-4"
T
THRESHOLD
ANCHOR PER MANUF.
RECOMMENDATIONS
DOOR, SEE SCHD.
EXISTING VAPOR BARRIER -
OVERLAP NEW VAPOR
BARRIER OLD MINIMUM 6"
AND SEAL W/ TAPE
FILL ALL VOIDS W/
BATT INSULATION
NEW GWB SOFFIT
ALUM FRAMEBACKER ROD & SEALANT,
WEEP TUBES @ 18" O.C.
EXISTING PRECAST
WINDOW LINTEL
L 3X3X1/4 - FASTEN TO
EXISTING PRE-CAST
LINTEL
EXISTING BATT INSULATION
ALUM DOOR
ALUM. WINDOW FRAME
GLAZING
BREAK METAL FILLER
120°
EXISTING VAPOR BARRIER - OVERLAP
NEW VAPOR BARRIER OLD MINIMUM 6"
AND SEAL W/ TAPE
FILL ALL VOIDS W/
BATT INSULATION
NEW GWB SOFFIT
WINDOW CLIP, SS FASTENERS
AND NEWPRENE SHIMS BY
WINDOW MANUFACTURER
BACKER ROD & SEALANT,
WEEP TUBES @ 18" O.C.
EXISTING PRECAST
WINDOW LINTEL
L 3X3X1/4 - FASTEN TO EXISTING
PRE-CAST LINTEL
EXISTING BATT INSULATION
HIDDEN UNDER COUNTER BRACING
(16" O.C. MAXIMUM)
1'-0"6"
SS-1
1HR WALL MOUNTED ROLLING
SHUTTER DOOR - INSTALL PER
MANUFACTURERS RECOMMENDATIONS
DOUBLE METAL BOX
HEADER @ HEADER
WOOD BLOCKING
4" 3'
-6
4"
W6
GLAZING BRACKET
1H-112C
WOOD BLOCKING - PROVIDE
AS NEEDED
3' -0
A F
F
A503
TYP
ALUM. WINDOW FRAME
GLAZING
BACKER ROD &
SEALANT
FLASHING
SELF-ADHERED
MEMEBRANE FLASHING
COUNTINOUS CAULKING - TYP
on e-ei gh th in ch o ne fo ot on e-qu ar te r ne fo ot th re e-ei gh th s ne fo ot on e-ha lf ne fo ot th re e-qu ar te r ne fo ot in ch on e ne fo ot on e an d on e-ha lf ne fo ot th re e in es ne fo ot
REVISIONS DATE
G E
N E
R A
L N
O T
E S
GENERAL CONTRACTOR AND/OR ALL SUBCONTRACTORS SHALL FIELD VERIFY ALL DIMENSIONS SHOWN ON THESE PLANS AND SHALL BE RESPONSIBLE FOR VARIATIONS BETWEEN PLAN DIMENSIONS AND ACTUAL FIELD DIMENSIONS. WHERE VARIATIONS ARE FOUND TO OCCUR, THE CONTRACTOR SHALL NOTIFY THE PROJECT ENGINEER IN WRITING PRIOR TO PROCEEDING WITH CONSTRUCTION; NO ADJUSTMENT TO
THE WORK WILL BE MADE WITHOUT THE PRIOR APPROVAL OF THE PROJECT ENGINEER.
GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR GENERAL DEMOLITION INCLUDING REMOVAL OF WALLS, PARTITIONS, DOORS & CEILING & FLOORS. ANY AND ALL CUTTING OF CONCRETE FLOORS, WALLS OR STRUCTURE SHALL BE THE GENERAL CONTRACTOR'S RESPONSIBILITY. CORE DRILLING THROUGH CONCRETE WALLS, FLOORS OR STRUCTURE FOR PIPING OR CONDUIT SHALL BE THE RESPONSIBILITY OF THE SUBCONTRACTOR BY TRADE; FIRESTOPPING OF THESE OPENINGS SHALL BE DONE BY THE RESPECTIVE SUBCONTRACTOR. REMOVAL OF DEBRIS RESULTING FROM DEMOLITION, CUTTING, AND/OR DRILLING IS THE RESPONSIBILITY OF THE GENERAL CONTRACTOR. PATCHING AND REPAIR OF CONCRETE WALLS, FLOOR, OR STRUCTURE SHALL BE THE RESPONSIBILITY OF THE GENERAL CONTRACTOR; THIS WILL BE ACCOMPLISHED UPON COMPLETION OF THE INSTALLATION OF ANY AND ALL UTILITIES INSTALLED
BY THE VARIOUS SUBCONTRACTORS.
Approved: Division Chief
Date Checked Drawn
DRAWING NO.
Building Number
Project No.Drawing Title Project Title
Location
Office of Facilities
Management Drawing Scale
Approved: Service DirectorPlot Scale
Renovate Mental Health Inpatient Ward
TRUE NORTH
PLAN NORTH
3" = 1'-0"
C
U s e rs
\P u b lic
\D o c u m e n ts
\R e v it P ro je c ts
\R -C
P S
M P
L S
I P
M H
S
S c h lo tt h a u e r.
rv t
/1
/2
:1 :4
A
M
4/12/2021 RJO JJG
618-17-127
1338 - A703
DOOR & WINDOW DETAILS
1 Veterans Dr., Minneapolis, MN 55417
3" = 1'-0"
DOOR DETAILS
3" = 1'-0"
WINDOW HEAD DETAIL
3" = 1'-0"
WINDOW SILL DETAIL
3" = 1'-0"
WINDOW SILL DETAIL @ PRECAST SILL
3" = 1'-0"
EXTERIOR STOREFRONT DOOR
3" = 1'-0"
OUTSIDE CORNER DETAIL
3" = 1'-0"
NOT USED
3" = 1'-0"
NOT USED
3" = 1'-0"
WINDOW HEAD DETAIL
3" = 1'-0"
SECTION DETAIL-PASS-THRU WINDOW
3" = 1'-0"
EXTERIOR JAMB DETAIL
3" = 1'-0"
NOT USED
3" = 1'-0"
NOT USED
3" = 1'-0"
.NOT USED
3" = 1'-0"
NOT USED .
on e-ei gh th ne fo ot on e-qu ar te r ne fo ot th re e-ei gh th s ne fo ot on e-ha lf ne fo ot th re e-qu ar te r ne fo ot in ch on e ne fo ot on e an d on e-ha lf ne fo ot th re e in es ne fo ot
REVISIONS DATE
G E
N E
R A
L N
O T
E S
GENERAL CONTRACTOR AND/OR ALL SUBCONTRACTORS SHALL FIELD VERIFY ALL DIMENSIONS SHOWN ON THESE PLANS AND SHALL BE RESPONSIBLE FOR VARIATIONS BETWEEN PLAN DIMENSIONS AND ACTUAL FIELD DIMENSIONS. WHERE VARIATIONS ARE FOUND TO OCCUR, THE CONTRACTOR SHALL NOTIFY THE PROJECT ENGINEER IN WRITING PRIOR TO PROCEEDING WITH CONSTRUCTION; NO ADJUSTMENT TO
THE WORK WILL BE MADE WITHOUT THE PRIOR APPROVAL OF THE PROJECT ENGINEER.
GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR GENERAL DEMOLITION INCLUDING REMOVAL OF WALLS, PARTITIONS, DOORS & CEILING & FLOORS. ANY AND ALL CUTTING OF CONCRETE FLOORS, WALLS OR STRUCTURE SHALL BE THE GENERAL CONTRACTOR'S RESPONSIBILITY. CORE DRILLING THROUGH CONCRETE WALLS, FLOORS OR STRUCTURE FOR PIPING OR CONDUIT SHALL BE THE RESPONSIBILITY OF THE SUBCONTRACTOR BY TRADE; FIRESTOPPING OF THESE OPENINGS SHALL BE DONE BY THE RESPECTIVE SUBCONTRACTOR. REMOVAL OF DEBRIS RESULTING FROM DEMOLITION, CUTTING, AND/OR DRILLING IS THE RESPONSIBILITY OF THE GENERAL CONTRACTOR. PATCHING AND REPAIR OF CONCRETE WALLS, FLOOR, OR STRUCTURE SHALL BE THE RESPONSIBILITY OF THE GENERAL CONTRACTOR; THIS WILL BE ACCOMPLISHED UPON COMPLETION OF THE INSTALLATION OF ANY AND ALL UTILITIES INSTALLED
BY THE VARIOUS SUBCONTRACTORS.
Approved: Division Chief
Date Checked Drawn
DRAWING NO.
Building Number
Project No.Drawing Title Project Title
Location
Office of Facilities
Management Drawing Scale
Approved: Service DirectorPlot Scale
Renovate Mental Health Inpatient Ward
TRUE NORTH
PLAN NORTH
3" = 1'-0"
C
U s e rs
\P u b lic
\D o c u m e n ts
\R e v it P ro je c ts
\R -C
P S
M P
L S
I P
M H
S
S c h lo tt h a u e r.
rv t
/1
/2
:1 :4
A
M
4/12/2021 RJO JJG
618-17-127
1338 - A703
DOOR & WINDOW DETAILS
1 Veterans Dr., Minneapolis, MN 55417
REVISION SET 4
| Sheets |
| A703 - DOOR & WINDOW DETAILS |
File details come from the government source that posted it. Updated .