ADD-1_Irrigation Plan Sheets.pdf
PDF 7 MB Posted
- Solicitation number
- 36C78621B0012
About this file
This notice is for a federal contract solicitation to expand gravesites and build a new bathroom at the National Memorial Cemetery of the Pacific in Honolulu, Hawaii. The Department of Veterans Affairs intends to issue an invitation for bid around July 15, 2021 for project number 899-030. The work includes gravesite expansion, construction of a new bathroom, and installation of irrigation systems. The NAICS code is 237990 and the business size standard is $36.5 million. This procurement is reserved exclusively for verified Service-Disabled Veteran-Owned Small Businesses. Offerors must be registered in the System for Award Management and Vendor Information Pages databases. The point of contact is listed for any questions.
View the file
Other files
Show all 25
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
WSC
POC 2
CUT/CAP EXISTING
IRRIGATION LINE -
CONFIRM ACTUAL
LOCATION IN FIELD
TIE INTO EXISTING
IRRIGATION LINE -
CONFIRM ACTUAL
LOCATION IN FIELD
C
TEMPORARY IRRIGATION
ZONE FOR PLANT
ESTABLISHMENT - PIPE LAID
ON TOP OF SURFACE AND
SECURED
POC 1
CUT/CAP EXISTING
IRRIGATION LINE -
CONFIRM ACTUAL
LOCATION IN FIELD
TIE INTO EXISTING
IRRIGATION LINE -
CONFIRM ACTUAL
LOCATION IN FIELD
SCH. 80 2" PVC FOR TEMP
IRRIGATION ZONE(S)
4"
1-1/2" Electric Valve
REVIEW AS-BUILT DRAWINGS FOR
REPAIRING AND/OR REPLACEMENT
OF ANY EXISTING IRRIGATION
EQUIPMENT DISTURBED IN
ROADWAY CONSTRUCTION LIMITS
FUTURE 6" IRRIGATION MAINLINE
TO BE CAPPED BY IRRIGATION
CONTRACTOR
01 01
01 01
01 01
01 01
E
E
C
C
C
01 01 01
01 01
8 8 8 8
8 8 8 8
5 5
5 5
E
E C
E
E C
51 51 51 51
51 51
51 51
E
E
TEMPORARY IRRIGATION
ZONE FOR PLANT
ESTABLISHMENT - PIPE LAID
ON TOP OF SURFACE AND
SECURED
4"
3"
3"
4"
3"
2"
SEE APPENDIX FOR EXISTING
RECORD DRAWINGS - CONFIRM
ACTUAL LOCATION IN FIELD
SEE APPENDIX FOR EXISTING
RECORD DRAWINGS - CONFIRM
ACTUAL LOCATION IN FIELD
ADJUST CURRENT SPRINKLERS
TO P.C.'S TO KEEP COVERAGE
OUT OF LANDSCAPE AREAS
PULL POWER WIRE FROM POWER
PEDESTAL FOR IRRIGATION
CONTROLLER(S) AND WEATHER
STATION - SEE ELECTRICAL PLAN
1 9.18 1"
2 11.4 1"
3 10.1 1"
4 9.52 1"
5 4.74 1"
6 9.22 1"
7 14.3 1"
8 7.92 1"
10 8.45 1"
12 7.92 1"
13 14.3 1"
14 7.04 1"
15 8.45 1"
16 3.06 1"
17 9.38 1"
18 1.50 1"
19 5.20 1"
20 6.88 1"
21 0.94 1"
23 10.1 1"
24 10.5 1"
279.14 1"
289.14 1"
30X 1"
316.63 1"
3211.3 1"
3315.0 1"
344.72 1"
351.40 1"
363.96 1"
375.20 1"
3813.1 1"
398.94 1"
409.01 1"
418.53 1"
4215.2 1"
4315.2 1"
4415.1 1"
4511.5 1"
460.94 1"
4710.1 1"
9 1.00 1"
11 1.00 1"
22 1.00 1"
25 1.00 1"
261.00 1"
291.00 1"
REV 1
REV 1
SYMBOL MANUFACTURER/MODEL/DESCRIPTION
Hunter PROS-04-PRS30-CV Strip Spray Turf Spray, 30psi regulated 4" pop-up with factory installed drain check valve.
Hunter PROS-04-PRS30-CV 8` Radius Nozzle Turf Spray, 30psi regulated 4" pop-up with factory installed drain check valve.
Hunter PROS-04-PRS30-CV 10` Radius Nozzle Turf Spray, 30psi regulated 4" pop-up with factory installed drain check valve.
Hunter PROS-04-PRS30-CV 12` Radius Nozzle Turf Spray, 30psi regulated 4" pop-up with factory installed drain check valve.
Hunter PROS-04-PRS30-CV 15` Radius Nozzle Turf Spray, 30psi regulated 4" pop-up with factory installed drain check valve.
Hunter PROS-12-PRS30-CV Strip Spray Shrub Spray, 30 psi regulated 12.0" Pop-Up. With Factory Installed Drain Check Valve. Co-molded wiper seal with UV Resistant Material.
Hunter PROS-12-PRS30-CV 5` Radius Nozzle Shrub Spray, 30 psi regulated 12.0" Pop-Up. With Factory Installed Drain Check Valve. Co-molded wiper seal with UV Resistant Material.
Hunter PROS-12-PRS30-CV 8` Radius Nozzle Shrub Spray, 30 psi regulated 12.0" Pop-Up. With Factory Installed Drain Check Valve. Co-molded wiper seal with UV Resistant Material.
Hunter PROS-12-PRS30-CV 10` Radius Nozzle Shrub Spray, 30 psi regulated 12.0" Pop-Up. With Factory Installed Drain Check Valve. Co-molded wiper seal with UV Resistant Material.
Hunter PROS-12-PRS30-CV 12` Radius Nozzle Shrub Spray, 30 psi regulated 12.0" Pop-Up. With Factory Installed Drain Check Valve. Co-molded wiper seal with UV Resistant Material.
Hunter PROS-12-PRS30-CV 15` Radius Nozzle Shrub Spray, 30 psi regulated 12.0" Pop-Up. With Factory Installed Drain Check Valve. Co-molded wiper seal with UV Resistant Material.
Rain Bird RWS-B-C 1401 Root Watering System with 4.0" diameter x 36.0" long with locking grate, semi-rigid mesh tube, and check valve.
SYMBOL MANUFACTURER/MODEL/DESCRIPTION
Hunter I-20-04 W/ MPR-35 Nozzles Turf Rotor, 4.0" Pop-Up. Adjustable and Full Circle. Plastic Riser. Drain Check Valve. MPR-35 Nozzles.
SYMBOL MANUFACTURER/MODEL/DESCRIPTION
Netafim LVCZS8010075-LF Pre-Assembled Control Zone Kit, with 1" Series 80 Control Valve, 3/4" Disc Filter, and Low Flow Pressure Regulator 0.25GPM to
4.4GPM.
SYMBOL MANUFACTURER/MODEL/DESCRIPTION
Griswold 100-DWS-PRV 1" Brass, In-Line, On-Off, Solenoid Control Valve, Normally Closed, Self-Cleaning, Slow-Closing and Opening Feature.
Pressure Reducing.
Nelson 7643 (Or Equal) 1" Brass quick coupler valve with ACME threads for slow flow control, with locking rubber cover.
Griswold Isolator B (Or Equal) Brass DWS Valve With Union Ball Valve. Includes plug in boss.
Line Sized.
Rain Master Laguna DXi Controller Laguna DXi w/ Remote Control System to Match Existing. Coordinate Location With RE and/or Cemetery Staff Prior to Construction.
Weather Station Relocate Existing Weather Station From Designated Demolition Area and Coordinate New Location With RE and/or Cemetery Staff Prior to Construction.
Point of Connection
Irrigation Lateral Line: PVC Schedule 40 (All 1" Unless Otherwise Noted On Plan)
Irrigation Mainline: PVC Schedule 40 (Size Per Plan)
Pipe Sleeve: PVC Schedule 40
(2) Sizes Larger Than Pipe Carried
ES CS SSRCSLCS
E L R C S
Q H F
5 5 5
FHTQ
8 8 8 8
Q T H F
01 01 01 01
Q T H TT TQ F
21 21 21 21 21 21
Q T H TT TQ F
51 51 51 51 51 51
C
WS
POC #
LEGEND
REV 1
REV 1
REV 1
NORTH
0 feet40
1" = 20'
20 60
EC CC
SITE IRRIGATION PLAN -
COLUMBARIUM COURT 14
IR101
BIDDING DOCUMENTS
BASE BID
Geotechnical Engineering
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
F i l e
P a t h e c d s e r v e r p c n e t s h a r e c o l e s p r o j e c t s n m c p h o n o l u l u n m c p h o n o l u l u i r r i g a t i o n r e v d w g e d i t n s n a v e d
A
M p l o t
A
M
Office of Design and Construction Services
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
Project Director
Revisions:
1 3 6 0 5 1 s t A v e . N . # 1 0 0 P l y m o u t h , M N 5 5 4 4 1 P 7 6 3 . 4 1 2 . 4 0 0 0 | F 7 6 3 . 4 1 2 . 4 0 9 0 | a e - m n . c o m Anderson Engineering of Minnesota, LLC | Proj # 15785
NMCP
GRAVESITE EXPANSION AND
CEMETERY IMPROVEMENTS
899CM3030
JULY 15, 2021
HONOLULU, HAWAII
BIDDING DOCUMENTS
BIDDING DOCUMENTS
Date:
Mechanical, Electrical, Technology & Structural Engineering:
IMEG, Inc.
623 26th Avenue Rock Island, IL 61201
(309) 788-0673 Wade Ross
Irrigation Consulting
EC Design Group, Ltd 400 5th St.
West Des Moines, IA 50265
(515) 225-6365 Erik Christiansen
Cost Estimating, Scheduling, Value Engineering
Leland Saylor Associates 1777 Oakland Blvd #103 Walnut Creek, CA 94596
(310) 207-6900 Tommy Vest
Kokua Geotech, LLC 94-974 Pakela St., Suite 109 Waipahu, HI 96797
(808) 397-6974 Tim (Xiaobin) Lin
OF 13892
09/14/21ADDENDUM 1
POC 3
TIE INTO EXISTING
IRRIGATION LINE -
CONFIRM ACTUAL
LOCATION IN FIELD
TIE INTO EXISTING
IRRIGATION LINE -
CONFIRM ACTUAL
LOCATION IN FIELD
CUT/CAP EXISTING
IRRIGATION LINE -
CONFIRM ACTUAL
LOCATION IN FIELD
CUT/CAP EXISTING
IRRIGATION LINE -
CONFIRM ACTUAL
LOCATION IN FIELD
POC 4
TIE INTO EXISTING
DRIP ZONE -
CONFIRM ACTUAL
LOCATION IN FIELD
CUT/CAP EXISTING
IRRIGATION LINE -
CONFIRM ACTUAL
LOCATION IN FIELD
TIE INTO EXISTING
IRRIGATION LINE -
CONFIRM ACTUAL
LOCATION IN FIELD
REVIEW AS-BUILT DRAWINGS FOR
REPAIRING AND/OR REPLACEMENT
OF ANY EXISTING IRRIGATION
EQUIPMENT DISTURBED IN
ROADWAY CONSTRUCTION LIMITS
VERIFY STATION COUNTS AND
CONNECT NEW IRRIGATION VALVES
TO EXISTING CONTROLLER(S)
FUTURE 6" IRRIGATION MAINLINE
TO BE CAPPED BY IRRIGATION
CONTRACTOR
5 5
01 01
5 5
3"
3"
SEE APPENDIX FOR EXISTING
RECORD DRAWINGS - CONFIRM
ACTUAL LOCATION IN FIELD
487.54 1"
4912.4 1"
503.99 1"
517.50 1"
5212.0 1"
532.10 1"
5410.0 1"
5512.0 1"
56- 1"
REV 1
SYMBOL MANUFACTURER/MODEL/DESCRIPTION
Hunter PROS-04-PRS30-CV Strip Spray Turf Spray, 30psi regulated 4" pop-up with factory installed drain check valve.
Hunter PROS-04-PRS30-CV 8` Radius Nozzle Turf Spray, 30psi regulated 4" pop-up with factory installed drain check valve.
Hunter PROS-04-PRS30-CV 10` Radius Nozzle Turf Spray, 30psi regulated 4" pop-up with factory installed drain check valve.
Hunter PROS-04-PRS30-CV 12` Radius Nozzle Turf Spray, 30psi regulated 4" pop-up with factory installed drain check valve.
Hunter PROS-04-PRS30-CV 15` Radius Nozzle Turf Spray, 30psi regulated 4" pop-up with factory installed drain check valve.
Hunter PROS-12-PRS30-CV Strip Spray Shrub Spray, 30 psi regulated 12.0" Pop-Up. With Factory Installed Drain Check Valve. Co-molded wiper seal with UV Resistant Material.
Hunter PROS-12-PRS30-CV 5` Radius Nozzle Shrub Spray, 30 psi regulated 12.0" Pop-Up. With Factory Installed Drain Check Valve. Co-molded wiper seal with UV Resistant Material.
Hunter PROS-12-PRS30-CV 8` Radius Nozzle Shrub Spray, 30 psi regulated 12.0" Pop-Up. With Factory Installed Drain Check Valve. Co-molded wiper seal with UV Resistant Material.
Hunter PROS-12-PRS30-CV 10` Radius Nozzle Shrub Spray, 30 psi regulated 12.0" Pop-Up. With Factory Installed Drain Check Valve. Co-molded wiper seal with UV Resistant Material.
Hunter PROS-12-PRS30-CV 12` Radius Nozzle Shrub Spray, 30 psi regulated 12.0" Pop-Up. With Factory Installed Drain Check Valve. Co-molded wiper seal with UV Resistant Material.
Hunter PROS-12-PRS30-CV 15` Radius Nozzle Shrub Spray, 30 psi regulated 12.0" Pop-Up. With Factory Installed Drain Check Valve. Co-molded wiper seal with UV Resistant Material.
Rain Bird RWS-B-C 1401 Root Watering System with 4.0" diameter x 36.0" long with locking grate, semi-rigid mesh tube, and check valve.
SYMBOL MANUFACTURER/MODEL/DESCRIPTION
Hunter I-20-04 W/ MPR-35 Nozzles Turf Rotor, 4.0" Pop-Up. Adjustable and Full Circle. Plastic Riser. Drain Check Valve. MPR-35 Nozzles.
SYMBOL MANUFACTURER/MODEL/DESCRIPTION
Netafim LVCZS8010075-LF Pre-Assembled Control Zone Kit, with 1" Series 80 Control Valve, 3/4" Disc Filter, and Low Flow Pressure Regulator 0.25GPM to
4.4GPM.
SYMBOL MANUFACTURER/MODEL/DESCRIPTION
Griswold 100-DWS-PRV 1" Brass, In-Line, On-Off, Solenoid Control Valve, Normally Closed, Self-Cleaning, Slow-Closing and Opening Feature.
Pressure Reducing.
Nelson 7643 (Or Equal) 1" Brass quick coupler valve with ACME threads for slow flow control, with locking rubber cover.
Griswold Isolator B (Or Equal) Brass DWS Valve With Union Ball Valve. Includes plug in boss.
Line Sized.
Rain Master Laguna DXi Controller Laguna DXi w/ Remote Control System to Match Existing. Coordinate Location With RE and/or Cemetery Staff Prior to Construction.
Weather Station Relocate Existing Weather Station From Designated Demolition Area and Coordinate New Location With RE and/or Cemetery Staff Prior to Construction.
Point of Connection
Irrigation Lateral Line: PVC Schedule 40 (All 1" Unless Otherwise Noted On Plan)
Irrigation Mainline: PVC Schedule 40 (Size Per Plan)
Pipe Sleeve: PVC Schedule 40
(2) Sizes Larger Than Pipe Carried
ES CS SSRCSLCS
E L R C S
Q H F
5 5 5
FHTQ
8 8 8 8
Q T H F
01 01 01 01
Q T H TT TQ F
21 21 21 21 21 21
Q T H TT TQ F
51 51 51 51 51 51
C
WS
POC #
LEGEND
REV 1
REV 1
REV 1
NORTH
0 feet40
1" = 20'
20 60
EC CC
SITE IRRIGATION PLAN -
RESTROOM
IR102
BIDDING DOCUMENTS
BASE BID
Geotechnical Engineering
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
F i l e
P a t h e c d s e r v e r p c n e t s h a r e c o l e s p r o j e c t s n m c p h o n o l u l u n m c p h o n o l u l u i r r i g a t i o n r e v d i t n v e d o t
A
M
Office of Design and Construction Services
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
Project Director
Revisions:
1 3 6 0 5 1 s t A v e . N . # 1 0 0 P l y m o u t h , M N 5 5 4 4 1 P 7 6 3 . 4 1 2 . 4 0 0 0 | F 7 6 3 . 4 1 2 . 4 0 9 0 | a e - m n . c o m Anderson Engineering of Minnesota, LLC | Proj # 15785
NMCP
GRAVESITE EXPANSION AND
CEMETERY IMPROVEMENTS
899CM3030
JULY 15, 2021
HONOLULU, HAWAII
BIDDING DOCUMENTS
BIDDING DOCUMENTS
Date:
Mechanical, Electrical, Technology & Structural Engineering:
IMEG, Inc.
623 26th Avenue Rock Island, IL 61201
(309) 788-0673 Wade Ross
Irrigation Consulting
EC Design Group, Ltd 400 5th St.
West Des Moines, IA 50265
(515) 225-6365 Erik Christiansen
Cost Estimating, Scheduling, Value Engineering
Leland Saylor Associates 1777 Oakland Blvd #103 Walnut Creek, CA 94596
(310) 207-6900 Tommy Vest
Kokua Geotech, LLC 94-974 Pakela St., Suite 109 Waipahu, HI 96797
(808) 397-6974 Tim (Xiaobin) Lin
OF 13893
POC 3
TEMPORARY IRRIGATION
ZONE FOR PLANT
ESTABLISHMENT - PIPE LAID
ON TOP OF GROUND
SURFACE AND SECURED
CONNECT TO BASE BID
MAINLINE - CONFIRM ACTUAL
LOCATION IN FIELD
3"
2"
SCH. 80 2" PVC FOR TEMP
IRRIGATION ZONE(S)
1-1/2" Electric Valve
TIE INTO EXISTING
IRRIGATION LINE -
CONFIRM ACTUAL
LOCATION IN FIELD
01 01
01 01
010101
5 8
8 8
8 01
01 01
0101 01 01 01
5 5 5
010101
8 8
E C C E
010101
51 51 51 51
51 51 51 51 51
51 51
51 51
51 51 51 51 51 51
3"
3"
4"
4" 4"
2"
2"
2"
4" 4"
4"
2"
4"
SEE APPENDIX FOR EXISTING
RECORD DRAWINGS - CONFIRM
ACTUAL LOCATION IN FIELD
SEE APPENDIX FOR EXISTING
RECORD DRAWINGS - CONFIRM
ACTUAL LOCATION IN FIELD
57 6.36 1"
58 1.43 1"
59 17.2 1"
60 3.02 1"
61 17.2 1"
62 9.32 1"
63 9.08 1"
64 12.0 1"
65 5.66 1"
67 4.60 1"
68 6.76 1"
69 5.88 1"
66 4.74 1"
70 1.00 1"
71 1.00 1"
72 19.1 1"
73 15.2 1"
74 19.1 1"
75 3.72 1"
76 10.5 1"
77 1.00 1"
78 1.00 1"
79 7.14 1"
80 6.55 1"
81 1.00 1"
82 8.22 1"
83 3.90 1"
84 5.95 1"
85 X 1"
86 1.90 1"
87 6.59 1"
88 6.59 1"
89 5.66 1"
2"
1"
1"
2"
1" 1"
2"
1"
1"
2"
1"
1"
REV 1
REV 1
REV 1
REV 1
REV 1
REV 1
SYMBOL MANUFACTURER/MODEL/DESCRIPTION
Hunter PROS-04-PRS30-CV Strip Spray Turf Spray, 30psi regulated 4" pop-up with factory installed drain check valve.
Hunter PROS-04-PRS30-CV 8` Radius Nozzle Turf Spray, 30psi regulated 4" pop-up with factory installed drain check valve.
Hunter PROS-04-PRS30-CV 10` Radius Nozzle Turf Spray, 30psi regulated 4" pop-up with factory installed drain check valve.
Hunter PROS-04-PRS30-CV 12` Radius Nozzle Turf Spray, 30psi regulated 4" pop-up with factory installed drain check valve.
Hunter PROS-04-PRS30-CV 15` Radius Nozzle Turf Spray, 30psi regulated 4" pop-up with factory installed drain check valve.
Hunter PROS-12-PRS30-CV Strip Spray Shrub Spray, 30 psi regulated 12.0" Pop-Up. With Factory Installed Drain Check Valve. Co-molded wiper seal with UV Resistant Material.
Hunter PROS-12-PRS30-CV 5` Radius Nozzle Shrub Spray, 30 psi regulated 12.0" Pop-Up. With Factory Installed Drain Check Valve. Co-molded wiper seal with UV Resistant Material.
Hunter PROS-12-PRS30-CV 8` Radius Nozzle Shrub Spray, 30 psi regulated 12.0" Pop-Up. With Factory Installed Drain Check Valve. Co-molded wiper seal with UV Resistant Material.
Hunter PROS-12-PRS30-CV 10` Radius Nozzle Shrub Spray, 30 psi regulated 12.0" Pop-Up. With Factory Installed Drain Check Valve. Co-molded wiper seal with UV Resistant Material.
Hunter PROS-12-PRS30-CV 12` Radius Nozzle Shrub Spray, 30 psi regulated 12.0" Pop-Up. With Factory Installed Drain Check Valve. Co-molded wiper seal with UV Resistant Material.
Hunter PROS-12-PRS30-CV 15` Radius Nozzle Shrub Spray, 30 psi regulated 12.0" Pop-Up. With Factory Installed Drain Check Valve. Co-molded wiper seal with UV Resistant Material.
Rain Bird RWS-B-C 1401 Root Watering System with 4.0" diameter x 36.0" long with locking grate, semi-rigid mesh tube, and check valve.
SYMBOL MANUFACTURER/MODEL/DESCRIPTION
Hunter I-20-04 W/ MPR-35 Nozzles Turf Rotor, 4.0" Pop-Up. Adjustable and Full Circle. Plastic Riser. Drain Check Valve. MPR-35 Nozzles.
SYMBOL MANUFACTURER/MODEL/DESCRIPTION
Netafim LVCZS8010075-LF Pre-Assembled Control Zone Kit, with 1" Series 80 Control Valve, 3/4" Disc Filter, and Low Flow Pressure Regulator 0.25GPM to
4.4GPM.
SYMBOL MANUFACTURER/MODEL/DESCRIPTION
Griswold 100-DWS-PRV 1" Brass, In-Line, On-Off, Solenoid Control Valve, Normally Closed, Self-Cleaning, Slow-Closing and Opening Feature.
Pressure Reducing.
Nelson 7643 (Or Equal) 1" Brass quick coupler valve with ACME threads for slow flow control, with locking rubber cover.
Griswold Isolator B (Or Equal) Brass DWS Valve With Union Ball Valve. Includes plug in boss.
Line Sized.
Rain Master Laguna DXi Controller Laguna DXi w/ Remote Control System to Match Existing. Coordinate Location With RE and/or Cemetery Staff Prior to Construction.
Weather Station Relocate Existing Weather Station From Designated Demolition Area and Coordinate New Location With RE and/or Cemetery Staff Prior to Construction.
Point of Connection
Irrigation Lateral Line: PVC Schedule 40 (All 1" Unless Otherwise Noted On Plan)
Irrigation Mainline: PVC Schedule 40 (Size Per Plan)
Pipe Sleeve: PVC Schedule 40
(2) Sizes Larger Than Pipe Carried
ES CS SSRCSLCS
E L R C S
Q H F
5 5 5
FHTQ
8 8 8 8
Q T H F
01 01 01 01
Q T H TT TQ F
21 21 21 21 21 21
Q T H TT TQ F
51 51 51 51 51 51
C
WS
POC #
LEGEND
REV 1
REV 1
REV 1
NORTH
0 feet60
1" = 30'
30 90
EC CC
SITE IRRIGATION PLAN - OPTION 1
IR103
BIDDING DOCUMENTS
OPTION 1
Geotechnical Engineering
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
F i l e
P a t h e c d s e r v e r p c n e t s h a r e c o l e s p r o j e c t s n m c p h o n o l u l u n m c p h o n o l u l u i r r i g a t i o n r e v d i t n v e d o t
A
M
Office of Design and Construction Services
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
Project Director
Revisions:
1 3 6 0 5 1 s t A v e . N . # 1 0 0 P l y m o u t h , M N 5 5 4 4 1 P 7 6 3 . 4 1 2 . 4 0 0 0 | F 7 6 3 . 4 1 2 . 4 0 9 0 | a e - m n . c o m Anderson Engineering of Minnesota, LLC | Proj # 15785
NMCP
GRAVESITE EXPANSION AND
CEMETERY IMPROVEMENTS
899CM3030
JULY 15, 2021
HONOLULU, HAWAII
BIDDING DOCUMENTS
BIDDING DOCUMENTS
Date:
Mechanical, Electrical, Technology & Structural Engineering:
IMEG, Inc.
623 26th Avenue Rock Island, IL 61201
(309) 788-0673 Wade Ross
Irrigation Consulting
EC Design Group, Ltd 400 5th St.
West Des Moines, IA 50265
(515) 225-6365 Erik Christiansen
Cost Estimating, Scheduling, Value Engineering
Leland Saylor Associates 1777 Oakland Blvd #103 Walnut Creek, CA 94596
(310) 207-6900 Tommy Vest
Kokua Geotech, LLC 94-974 Pakela St., Suite 109 Waipahu, HI 96797
(808) 397-6974 Tim (Xiaobin) Lin
OF 13894
SCALE:
THRUST BLOCK DETAIL
NONE
SCALE:
SLEEVING DETAIL
NONE
SCALE:
QUICK-COUPLING VALVE
WITH STABILIZER
NONESCALE:
ISOLATION VALVE WITH BOX
NONE
SCALE:
FIXED-SPRAY SPRINKLER
NONE
SCALE:
ELECTRIC VALVE W/ PRV
AND VALVE BOX
NONESCALE:
CONTROLLER
NONE
SCALE:
TEMPORARY ABOVE GRADE
IRRIGATION INSTALLATION
NONE
SCALE:
ROOT ZONE WATERING
SYSTEM
NONESCALE:
TEMPORARY TREE EMITTER LAYOUT
FOR ESTABLISHMENT
NONE SCALE:
ROOT ZONE WATERING SYSTEM W/
PLANT CONTAINMENT SYSTEM
NONE
EC CC
IRRIGATION DETAILS
IR501
BIDDING DOCUMENTS
Geotechnical Engineering
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
F i l e
P a t h e c d s e r v e r p c n e t s h a r e c o l e s p r o j e c t s n m c p h o n o l u l u n m c p h o n o l u l u i r r i g a t i o n r e v d i t n v e d o t
A
M
Office of Design and Construction Services
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
Project Director
Revisions:
1 3 6 0 5 1 s t A v e . N . # 1 0 0 P l y m o u t h , M N 5 5 4 4 1 P 7 6 3 . 4 1 2 . 4 0 0 0 | F 7 6 3 . 4 1 2 . 4 0 9 0 | a e - m n . c o m Anderson Engineering of Minnesota, LLC | Proj # 15785
NMCP
GRAVESITE EXPANSION AND
CEMETERY IMPROVEMENTS
899CM3030
JULY 15, 2021
HONOLULU, HAWAII
BIDDING DOCUMENTS
BIDDING DOCUMENTS
Date:
Mechanical, Electrical, Technology & Structural Engineering:
IMEG, Inc.
623 26th Avenue Rock Island, IL 61201
(309) 788-0673 Wade Ross
Irrigation Consulting
EC Design Group, Ltd 400 5th St.
West Des Moines, IA 50265
(515) 225-6365 Erik Christiansen
Cost Estimating, Scheduling, Value Engineering
Leland Saylor Associates 1777 Oakland Blvd #103 Walnut Creek, CA 94596
(310) 207-6900 Tommy Vest
Kokua Geotech, LLC 94-974 Pakela St., Suite 109 Waipahu, HI 96797
(808) 397-6974 Tim (Xiaobin) Lin
OF 13895
| IR101 - SITE IRRIGATION PLAN - COLUBARIUM COURT 14 |
| IR102 - SITE IRRGATION PLAN - RESTROOM |
| IR103 - SITE IRRIGATION PLAN - OPTION 1 |
| IR501 - IRRIGATION DETAILS |