RFI 59 Plumbing Drawing.pdf
PDF 1 MB Posted
- Solicitation number
- 36C77626R0035
About this file
These are architectural plumbing plan drawings for a new hospital facility at the VA Medical Center (VAMC) in Orlando, Florida, designated as Project Number 673-950. The drawings, prepared by the Office of Facilities Management and dated June 4, 2010, depict Bid Alternate No. 3 for Hospital/Clinic Level 1, encompassing Areas D and Zone 4-5 plumbing systems.
The plumbing plans illustrate comprehensive water supply, drainage, and vent piping systems throughout the medical facility. Key components include hot and cold water (HW/CW) supply lines ranging from 1/2" to 3/4" diameter, sanitary (SAN) and vent piping up to 6" diameter, roof drainage systems (both primary and secondary) with 8" to 15" diameter rainwater (RW) lines, and specialty connections for medical equipment including MRI rooms, imaging facilities, nuclear medicine areas, and CT scan units. The drawings specify floor-mounted air conditioning units for humidifiers with 3/4" cold water supply connections and condensate routing to floor drains with maintained 2" air gaps. Four Change Request (CPR) modifications are documented: CPR 122 (09/16/11), CPR 234 (02/16/12), CPR 236 (03/09/12), and CPR 382 (03/15/13). The facility is noted as fully sprinklered. Drawings reference related plumbing drawing sheets (H-PL1.1FD4-A, H-PL1.1FD5-A, H-PL1.1FE1, H-PL1.1FE2-A) and coordination with civil drawings for mobile MRI vehicle water supply connections.
View the file
Other files
Show all 32
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
PM
C
PM
C
15" SECONDARY
ROOF DRIANAGE.
24" ABOVE
FINISHED GRADE
(39170 S.F.)
15" RW UP &
DN (39170 S.F.)
8" RW UP &
DN (9705 S.F.)
15" SRW UP
(39170 S.F.)
P-528
P-528
P-528
P-401
P-528
P-401
P-401
P-701 P-401
P-401
P-528B P-505
P-528
P-528
P-528
P-560C
P-401
P-102
P-102
P-102
P-102
FLOOR
C.O.
FLOOR
C.O.
FLOOR
C.O.
FLOOR
C.O.
P-528
P-528
P-560C
P-803
P-803
6" CD UP & DN
FLOOR C.O.
FLOOR C.O.
2" W UP
& DN
1 1/2" V
UP & DN
1 1/2" V
UP & DN
H -P
L1 .1
FD
5-
A
H -P
L1 .1
FD
4-
A
H -P
L1 .1
FD
5-
A
H -P
L1 .1
FD
4-
A
C.T. (ED)
1E702
IMAGING RM-2
1K505c-2
MRI EQUIP
1E206a
HAC
1A609
WAIT
1M702
BIO MED OFFICE
1M204
NUC MED WAIT
1K510
VEST
1F201
CLEAN SUPPLY
1E604
NURSE
1F212
NURSE
1F214
IV PREP
1E304
STORAGE
1E402
ECG CUBICLE
1F404
ECG: CUBICLE
1F408
ECG CUBICLE
1F406
STRETCHER
HOLD
1E301
RECEPTION
1E305
MRI WAIT
1E501
STAFF PHYSICIAN
1K802
STAFF PHYSICIAN
1K804
STAFF PHYSICIAN
1K806
C.T. (#2)
1E605
C.T.
1E601
NURSE
1F206
NURSE
1F204
NURSE
1F202
NURSE
1F208
NURSE
1F210
CORRIDOR
1MC02
COMPUTER
EQUIPMENT
1E201
CLEAN SUPPLY
1E205
SOILED UTILITY
1E203
PHYSICIAN
1F301
CORRIDOR
1EC07
CONTROL RM
1E603
NURSE
PRACTIONER
1K705
TLT
1E404
DRESS
1E403
DRESS
1E401
CORRIDOR
1EC03
CLEAN SUPPLY
1K203
PATIENT DOSE
1K205
READING/CONSULT
1K502
RECEPTION
1K508
RSO/PHYSICIST
OFFICE
1K504
EXAM RM
1K509
TLT
1K511
PASSAGE
1KC08
CHIEF NUC MED
OFFICE
1K807
PROFESS
NON-PHYSICIAN
1K805
STAFF PHYSICIAN
1K803
CORRIDOR
1EC05
CHEST RM
1M206
COMMON
VIEWING RM
1K801
STAFF TLT
1F402
ENTRY
1K505
THYROID UPTAKE
1K503
TECH WORK
AREA
1K505d
CORRIDOR
1KC05
TLT
1K513
CORRIDOR
1KC06
ELEC
1E610
CORRIDOR
1EC06
CORRIDOR
1KC07
EQUIP
1KC06a
CORRIDOR
1FC02
IMAGING RM
1K505a
IMAGING RM
1K505b
CORRIDOR
1EC04
CRASH CART
1E306
WHEELCHAIR &
STRETCHER
WAITING
1E608
MRI ROOM
1E202
MRI CONTROL
1E302
MRI CONTROL
1E204
CORRIDOR
1EC02
MRI ROOM
1E206
NUC WASTE STOR
1K202
IV PREP
1K214a
PET SIM UPTAKE
1K212
PET UPTAKE
1K210
UPTAKE
1K208
UPTAKE
1K206
CORRIDOR
1KC02
CORRIDOR
1EC01
10" SECONDARY ROOF DRIANAGE. 24"
ABOVE FINISHED GRADE (18616 SF)
3" RW UP & DN (1297 S.F.)
3" V UP & DN
P-806
MOUNT 1'-6" O.C. ABOVE
ASSOCIATED LEVEL.
1" CW DN
1" CW DN
FLOOR C.O.
FLOOR C.O.
FOR EXACT LOCATION
OF 3/4" CW UP TO
YARD HYDRANT FOR
MOBILE MRI VECHICLE
SEE CIVIL DRAWING
WALL C.O.
FD-V
H-PL1.1FE1
H-PL1.1FD4-A
H-PL1.1FE1
H-PL1.1FD4-A
H-PL1.1FD4-A
H-PL1.1FD1
H-PL1.1FD4-A
H-PL1.1FD1
H -P
L1 .1
FE
2-
A
H -P
L1 .1
FE
3738394041
C
D
E
F
G
D.9
D.7
F.4
E.4
C.7
E.6
D.6
40.6 39.440.5
37.2
39.7
H-CRAC-12
H-CRAC-13
H-CRAC-14
FOR EXACT LOCATION
OF 3/4" CW UP TO
YARD HYDRANT FOR
MOBILE MRI VECHICLE
SEE CIVIL DRAWING
FD-C
FD-C
FLOOR
C.O.
ROUTE CONDENSATE
TO FLOOR DRAIN
MAINTAIN 2" AIR GAP
ROUTE
CONDENSATE TO
FLOOR DRAIN
MAINTAIN 2" AIR GAP
FLOOR
CO
N
1/8" = 1'-0" GRAPHIC SCALE
4' 8' 24'16'
A1
C2
KEY PLAN
C1
D3
D4
E2
A2 A3
B1 B2
AREA D, ZONE 4
D2
D5 D6
E1 E3
D1
Drawing Title
Approved: Project Director
Project Title
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
CONSULTANTS: ARCHITECT/ENGINEERS:
OFFICE OF
FACILITIES
MANAGEMENT
on e ei gh th in ch o ne f oo t
B
A
C
D
E
F th re e in ch es o ne f oo t
6"
6" on e an d on e ha lf in ch es o ne f oo t on e in ch o ne f oo t
6" 6" th re e qu ar te rs in ch o ne f oo t on e ha lf in ch o ne f oo t th re e ei gh th s in ch o ne f oo t on e qu ar te r in ch o ne f oo t
VA FORM 08-6231, OCT 1978
1 2 3 4 5 6 87 9
F
E
D
C
B
A
97 8654321
BUILDING IS FULLY SPRINKLERED
A NEW HOSPITAL FOR
VAMC ORLANDO, FLORIDA
Orlando, Florida
673-950
04 JUNE, 2010
Professional Seals:
EB / RLF
NOTES:
SHEET NOTES:
01 AND 02
4322Dwg. ofGO/PPG
ZONE 4 PLUMBING PLAN
BID ALTERNATE NO. 3
HOSPITAL/CLINIC LEVEL 1, AREA D,
H-PL1.1FD4-A
1. 1" PUMPED CONDENSATE TO PLUMBING DRAIN
LOCATED IN INTERSTITIAL SPACE BY
MECHANICAL.
2. 3/4" COLD WATER SUPPLY TO FLOOR MOUNTED
AIR CONDITIONING UNIT FOR HUMIDIFIERS.
No. Description Date
1 CPR 122 09/16/11
2 CPR 234 02/16/12
3 CPR 236 03/09/12
4 CPR 382 03/15/13
PM
C
PM
C
15" SECONDARY
ROOF DRIANAGE.
24" ABOVE
FINISHED GRADE
(39170 S.F.)
15" RW UP &
DN (39170 S.F.)
8" RW UP &
DN (9705 S.F.)
15" SRW UP
(39170 S.F.)
P-528
P-528
P-528
P-401
P-528
P-401
P-401
P-701 P-401
P-401
P-528B P-505
P-528
P-528
P-528
P-560C
P-401
P-102
P-102
P-102
P-102
FLOOR
C.O.
FLOOR
C.O.
FLOOR
C.O.
FLOOR
C.O.
P-528
P-528
P-560C
P-803
P-803
6" CD UP & DN
FLOOR C.O.
FLOOR C.O.
2" W UP
& DN
1 1/2" V
UP & DN
1 1/2" V
UP & DN
H -P
L1 .1
FD
5-
A
H -P
L1 .1
FD
4-
A
H -P
L1 .1
FD
5-
A
H -P
L1 .1
FD
4-
A
C.T. (ED)
1E702
IMAGING RM-2
1K505c-2
MRI EQUIP
1E206a
HAC
1A609
WAIT
1M702
BIO MED OFFICE
1M204
NUC MED WAIT
1K510
VEST
1F201
CLEAN SUPPLY
1E604
NURSE
1F212
NURSE
1F214
IV PREP
1E304
STORAGE
1E402
ECG CUBICLE
1F404
ECG: CUBICLE
1F408
ECG CUBICLE
1F406
STRETCHER
HOLD
1E301
RECEPTION
1E305
MRI WAIT
1E501
STAFF PHYSICIAN
1K802
STAFF PHYSICIAN
1K804
STAFF PHYSICIAN
1K806
C.T. (#2)
1E605
C.T.
1E601
NURSE
1F206
NURSE
1F204
NURSE
1F202
NURSE
1F208
NURSE
1F210
CORRIDOR
1MC02
COMPUTER
EQUIPMENT
1E201
CLEAN SUPPLY
1E205
SOILED UTILITY
1E203
PHYSICIAN
1F301
CORRIDOR
1EC07
CONTROL RM
1E603
NURSE
PRACTIONER
1K705
TLT
1E404
DRESS
1E403
DRESS
1E401
CORRIDOR
1EC03
CLEAN SUPPLY
1K203
PATIENT DOSE
1K205
READING/CONSULT
1K502
RECEPTION
1K508
RSO/PHYSICIST
OFFICE
1K504
EXAM RM
1K509
TLT
1K511
PASSAGE
1KC08
CHIEF NUC MED
OFFICE
1K807
PROFESS
NON-PHYSICIAN
1K805
STAFF PHYSICIAN
1K803
CORRIDOR
1EC05
CHEST RM
1M206
COMMON
VIEWING RM
1K801
STAFF TLT
1F402
ENTRY
1K505
THYROID UPTAKE
1K503
TECH WORK
AREA
1K505d
CORRIDOR
1KC05
TLT
1K513
CORRIDOR
1KC06
ELEC
1E610
CORRIDOR
1EC06
CORRIDOR
1KC07
EQUIP
1KC06a
CORRIDOR
1FC02
IMAGING RM
1K505a
IMAGING RM
1K505b
CORRIDOR
1EC04
CRASH CART
1E306
WHEELCHAIR &
STRETCHER
WAITING
1E608
MRI ROOM
1E202
MRI CONTROL
1E302
MRI CONTROL
1E204
CORRIDOR
1EC02
MRI ROOM
1E206
NUC WASTE STOR
1K202
IV PREP
1K214a
PET SIM UPTAKE
1K212
PET UPTAKE
1K210
UPTAKE
1K208
UPTAKE
1K206
CORRIDOR
1KC02
CORRIDOR
1EC01
10" SECONDARY ROOF DRIANAGE. 24"
ABOVE FINISHED GRADE (18616 SF)
3" RW UP & DN (1297 S.F.)
3" V UP & DN
P-806
MOUNT 1'-6" O.C. ABOVE
ASSOCIATED LEVEL.
1" CW DN
1" CW DN
FLOOR C.O.
FLOOR C.O.
FOR EXACT LOCATION
OF 3/4" CW UP TO
YARD HYDRANT FOR
MOBILE MRI VECHICLE
SEE CIVIL DRAWING
WALL C.O.
FD-V
H-PL1.1FE1
H-PL1.1FD4-A
H-PL1.1FE1
H-PL1.1FD4-A
H-PL1.1FD4-A
H-PL1.1FD1
H-PL1.1FD4-A
H-PL1.1FD1
H -P
L1 .1
FE
2-
A
H -P
L1 .1
FE
3738394041
C
D
E
F
G
D.9
D.7
F.4
E.4
C.7
E.6
D.6
40.6 39.440.5
37.2
39.7
H-CRAC-12
H-CRAC-13
H-CRAC-14
FOR EXACT LOCATION
OF 3/4" CW UP TO
YARD HYDRANT FOR
MOBILE MRI VECHICLE
SEE CIVIL DRAWING
FD-C
FD-C
FLOOR
C.O.
ROUTE CONDENSATE
TO FLOOR DRAIN
MAINTAIN 2" AIR GAP
ROUTE
CONDENSATE TO
FLOOR DRAIN
MAINTAIN 2" AIR GAP
FLOOR
CO
N
1/8" = 1'-0" GRAPHIC SCALE
4' 8' 24'16'
A1
C2
KEY PLAN
C1
D3
D4
E2
A2 A3
B1 B2
AREA D, ZONE 4
D2
D5 D6
E1 E3
D1
Drawing Title
Approved: Project Director
Project Title
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
CONSULTANTS: ARCHITECT/ENGINEERS:
OFFICE OF
FACILITIES
MANAGEMENT
on e ei gh th in ch o ne f oo t
B
A
C
D
E
F th re e in ch es o ne f oo t
6"
6" on e an d on e ha lf in ch es o ne f oo t on e in ch o ne f oo t
6" 6" th re e qu ar te rs in ch o ne f oo t on e ha lf in ch o ne f oo t th re e ei gh th s in ch o ne f oo t on e qu ar te r in ch o ne f oo t
VA FORM 08-6231, OCT 1978
1 2 3 4 5 6 87 9
F
E
D
C
B
A
97 8654321
BUILDING IS FULLY SPRINKLERED
A NEW HOSPITAL FOR
VAMC ORLANDO, FLORIDA
Orlando, Florida
673-950
04 JUNE, 2010
Professional Seals:
EB / RLF
NOTES:
SHEET NOTES:
01 AND 02
4322Dwg. ofGO/PPG
ZONE 4 PLUMBING PLAN
BID ALTERNATE NO. 3
HOSPITAL/CLINIC LEVEL 1, AREA D,
H-PL1.1FD4-A
1. 1" PUMPED CONDENSATE TO PLUMBING DRAIN
LOCATED IN INTERSTITIAL SPACE BY
MECHANICAL.
2. 3/4" COLD WATER SUPPLY TO FLOOR MOUNTED
AIR CONDITIONING UNIT FOR HUMIDIFIERS.
No. Description Date
1 CPR 122 09/16/11
2 CPR 234 02/16/12
3 CPR 236 03/09/12
4 CPR 382 03/15/13
FLOOR
C.O.
FLOOR C.O.
FLOOR C.O.
3" AW UP &
DN (28 FU)
3" AV UP & DN
4" VENT UP & DN
6" SAN UP & DN
6" SAN UP &
DN (141 FU)
4" VENT
UP & DN
P-528
P-528AP-528A
P-528
P-528
P-401
P-502
P-528A
P-528A
P-528A
P-528A
P-528A
P-401
P-401 P-401
P-528
P-528
P-401
P-401
P-202P-404
P-201
P-701
P-702
P-404
P-702
P-404
P-502
P-528
P-102
P-101 P-101
P-102
P-102 P-102
P-102
P-101
P-102
P-102
P-102
FLOOR C.O.
FLOOR
C.O.
FLOOR C.O.
FLOOR C.O.
FLOOR C.O.
3" SIDE OUTLET
AD TYPE A
P-102 P-528A
P-701
P-609
P-404
P-404
P-404
FLOOR
C.O.
2" W UP & DN
1 1/2" V UP
2" W UP & DN
FD-D
(TYP OF 3)
P-702
FLOOR C.O.
H-PL1.1FD5-A
H-PL1.1FD2-A
H -P
L
.1 F
D
-A
H -P
L
.1 F
D
-A
H -P
L
.1 F
D
-A
H -P
L
.1 F
D
-A
H-PL1.1FD5-A
H-PL1.1FD2-A
CLOSET
1C106
CLOSET
1C104
RAD/FLOURO
1M710
CONTROL
1M710a
1 1/2" V UP & DN
STAIR
1ES01
ELEVATOR
1EE02
ELEVATOR
1EE01
ELEVATOR
1FE02
ELEVATOR
1FE01
WAIT
1M702
BIO MED OFFICE
1M204
WAITING
1G404
OFFICE (PVA)
1N404
OFFICE
(FDVA/STATE)
1N203
RECEP(FDVA/STATE)
1N201
OFFICE
1H202
OFFICE
1H204
PASSAGE
1HC02
CHIEF
NON-INVASIVE
1F203
VEST
1F201
OFFICE
(FDVA/STATE)
1N204
OFFICE (DAV)
1N403
OFFICE
1N405
PHYSICIAN
1F303
CHIEF OF
CARDIOLOGY
1M715
ECG CUBICLE
1F404
STRESS
LAB/ECHO
1F602
STRESS
LAB/ECHO
1F604
STORAGE
1F101
ECG: CUBICLE
1F408
ECG CUBICLE
1F406
TLT
1F403
ELEC
1N601a
CORRIDOR
1FC04
CHIEF
1G403
PACEMAKER/HOLTER
MONITOR ROOM
1F307
CORRIDOR
1FC05
HAC
1F401
CORRIDOR
1FC03
Space
2C558
ECG/ECHO
READING
1F601
ECHO ROOM
1F605
CORRIDOR
1FC06
STRESS LAB
1F607
STRETCHER
ALCOVE
1FC04a
ECG CUBICLE
1F104
CORRIDOR
1FC01
OFFICE
(FDVA/STATE)
1N206
PASSAGE
1NC02
OFFICE
(FAVA/STATE)
1N205
CORRIDOR
1NC04
OFFICE (PVA)
1N406
LOCKERS MALE
1G302a
COMM
1N601b
CANTEEN RETAIL
1N601
POLICE TRAINING
ROOM
1H206
HAC
1G305
EVIDENCE STOR
1H206a
TLT & SHWR
FEMALE
1G303b
VESTIBULE
1G303
TRAINING ROOM
1G408
LOCKERS
FEMALE
1G303a
STORAGE
1G410
OFFICE(COUNTY)
1G101b
OFFICE(COUNTY)
1G101a
CO-ORDINATOR
1G406
OFFICE/ADMIN(DAV)
1N401
TLT & SHWR
MALE
1G302b
VESTIBULE
1G302
ENTRY
1GC04
SECRETARY
1G402
SERVICE OFFICER
1G401
PHYSICIAN
1F301 CARDIAC NUC
IMAGING
1F309
DRESS
1M704
PACS OFFICE
1M406
ADPAC OFFICE
1M404
DRESS
1M714
RAD/FLOURO
1M148
CHEST RM
1M206
CONTROL
1M206a
TLT
1M304
TLT
1M302
CORRIDOR
1MC03
WORK
1F808a
STAFF TLT
1F402
ECG ROOM
1F106
RADIOLOGY
LOCKERS AND
TOILETS
1M303
PASSAGE
1MC04
CONFERENCE
1M718
COMM
1M403
EMPLOYEE
BIO-SAFETY
1M307
ELEC
1M307a
ELEVATOR
LOBBY
1F716
CORRIDOR
1FC07
Space
2C933
TECH WORK
1M210
SOILED HOLD
1M306
RF TLT
1M706
RF TLT
1M712
PATIENT REP
1F804
ELEC
1F802
SECRETARY
1M717
OFFICE (VFW)
1N202
OFFICE/RECEP(PVA)
1N402
CORRIDOR
1GC01
PATIENT REP
1F806
PATIENT
STORAGE
1F716a
ELEV LOBBY
1GC02
WAITING/LOUNGE
1G101
COFFEE SHOP
1F808
CORRIDOR
1HC09
CORRIDOR
1MC08
ELEVATOR
1FE03
CHIEF TECH
OFFICE
1M402
PUBLIC TLT
1F808b
3/4" FW
1/2" CW
1/2" HW
3/4" 3/4"
3/4" 1/2" HW
1/2" FW
1/2"
1/2"
1"
HW & CW UP
FLOOR C.O.
FLOOR C.O.
FLOOR C.O.
CW UP
CW & HW UP
FLOOR C.O.
WALL C.O.
FLOOR C.O.
FLOOR C.O.
FLOOR C.O.
P-528A
H-PL4.001
H-PL4.001
H-PL1.1FE2-A
H-PL1.1FD5-A
H-PL1.1FE2-A
H-PL1.1FD5-A
H -P
L
.1 F
D
H -P
L
.1 F
D
-A
H -P
L
.1 F
D
H -P
L
.1 F
D
-A
H -P
L
.1 F
E
-A
H -P
L
.1 F
E
P-811
1.2
C
D
E
F
G
D.9
35.2
D.7
F.4
E.4
C.7
32333435 A7
C.81
C.91
32.532.7
33.6
P-811
P-811
P-811 P-811
P-811
FD-C
FD-C
P-528
1 1/2"
2"FD-C WITH
FUNNEL
N
1/8" = 1'-0" GRAPHIC SCALE
4' 8' 24'16'
A1
C2
KEY PLAN
AREA D, ZONE 5
C1
D3
D4
E2
A2 A3
B1 B2
D2
D5 D6
E1 E3
D1
1. 1/2" SAN UP.
2. 1/2" HW FROM SINK TO DISHWASHER. 1 1/2" DRAIN
FROM DISHWASHER TO SINK TAILPIECE.
3. NOTE NOT USED.
4. REFER TO KITCHEN CONSULTANT HQ-F SERIES
DRAWINGS FOR DRAIN LOCATIONS.
5. 1/2" CW FROM TRAP PRIMER TO FD-C.
6. 1 1/2" VENT FROM BELOW CONNECTION TO VENT
FROM URINAL P-201.
7. 1 1/2" VENT FROM BELOW CONNECTION TO VENT
FROM WATER CLOSET P-101.
8. EXTEND 1 1/2" SANITARY DRAIN FROM RELOCATED
P-528 SINK AND CONNECT TO EXISTING 2" VERTICAL
SANITARY DRAIN THAT CONTINUES DOWN THRU FLOOR.
9. PROVIDE CW, HW, VENT AND DRAIN STUB OUT FOR
FUTURE P-528A IN-COUNTER SINK INSTALLATION.
10. 1-1/2" VENT UP IN WALL TO INTERSTITIAL SPACE.
Drawing Title
Approved: Project Director
Project Title
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
CONSULTANTS: ARCHITECT/ENGINEERS:
OFFICE OF
FACILITIES
MANAGEMENT
o n e e ig h th i n c h o n e f o o t
B
A
C
D
E
F th re e i n c h e s o n e f o o t o n e a n d o n e h a lf i n c h e s o n e f o o t o n e i n c h o n e f o o t th re e q u a rt e rs i n c h o n e f o o t o n e h a lf i n c h o n e f o o t th re e e ig h th s i n c h o n e f o o t o n e q u a rt e r in c h o n e f o o t
VA FORM 08-6231, OCT 1978
1 2 3 4 5 6 87 9
F
E
D
C
B
A
97 8654321
BUILDING IS FULLY SPRINKLERED
A NEW HOSPITAL FOR
VAMC ORLANDO, FLORIDA
Orlando, Florida
673-950
04 JUNE, 2010
Professional Seals:
EB / RLF
NOTES:
SHEET NOTES:
01 AND 02
4322Dwg. ofGO/PPG
ZONE 5 PLUMBING PLAN
BID ALTERNATE NO. 3
HOSPITAL/CLINIC LEVEL 1, AREA D,
H-PL1.1FD5-A
No. Description Date
1 CPR 078 05-12-11
2 CPR 128 08/04/11
3 CPR 160 10/14/11
4 CPR 236 03/09/12
5 CPR 272 04/30/12
File details come from the government source that posted it. Updated .