RFI 59 Mechanical DWG.pdf

PDF 3 MB Posted

Attached to
Y1DZ--675-106 Expand Radiology & Oncology Minor Construction - Lake Nona
Solicitation number
36C77626R0035
Issued by

About this file

This document contains architectural ductwork plans for a new hospital facility at the Veterans Affairs Medical Center (VAMC) in Orlando, Florida. The plans are specifically for Level 1 of the Hospital/Clinic building, covering Areas D, Zones 4-6, and corresponding interstitial spaces, with provisions for Bid Alternate No. 3.

The drawings depict comprehensive HVAC ductwork layouts showing supply (CD-A, CD-B, ER-A, ER-C, ER-D), return (RR-A), and exhaust (SSR-A, SRR-A, TG-A, STG-A, SER-A, ANZ-B) duct installations with specified airflow rates in CFM (cubic feet per minute) throughout various hospital departments and rooms. Duct dimensions are provided in multiple formats (rectangular measurements and round diameter specifications). Key areas served include imaging rooms, CT scan facilities, MRI rooms, nuclear medicine departments, cardiology, pathology, dietary services, and administrative offices. The plans include equipment designations (H-CRAC units, H-MH terminal units, H-TU and H-FCU terminal units, H-F/SD fire-smoke dampers, H-EF exhaust fans, H-LEF louver-exhaust fans), with cross-references to interconnected systems shown on companion drawings (H-MH-1.1FD, H-MH-1.1ND, H-MH-1.1NE series). General notes indicate the building is fully sprinklered, and drawing notes reference standard plenum configurations, louver connections, and specialized installations such as an autopsy table exhaust system. The document is dated June 4, 2010, with multiple revision change orders (CPR) documented from 2011-2013, prepared by architects/engineers RLF (Rieth-Riley Facility Engineers) under VA Office of Facilities Management oversight.

View the file

Other files

File Type Posted
RFI 59 Electrical DWG.pdf PDF
RFI 59 Plumbing DWG.pdf PDF
RFI 59 Piping DWG.pdf PDF
Technical Questions Spreadsheet - Lake Nona - 4-27-26.docx DOCX document
36C77626R0035 0009.pdf PDF
Technical Questions Spreadsheet - Lake Nona - 4-24-26.docx DOCX document
36C77626R0035 0008.pdf PDF
RFI 59 Electrical Drawing.pdf PDF
RFI 59 Mechanical Drawing.pdf PDF
675-106 Addendum 02.pdf PDF
RFI 59 Plumbing Drawing.pdf PDF
Technical Questions Spreadsheet - Lake Nona - 4-22-26.docx DOCX document
36C77626R0035 0007.pdf PDF
36C77626R0035 0006.pdf PDF
CON-100 INSTRUCTIONS - Tradeoffs.docx DOCX document
36C77626R0035 0005.pdf PDF
36C77626R0035 0004.pdf PDF
Sign-in Sheet - Lake Nona.pdf PDF
36C77626R0035 0003.pdf PDF
36C77626R0035 0002.pdf PDF
Attachment 1 - Specifications.pdf PDF
Attachment 2 - Drawings.pdf PDF
Attachment 5 - Brand Name Justification - Redacted.pdf PDF
Attachment 10 - Project Information Sheet for Contractors.docx DOCX document
Attachment 6 - Construction Wage Rates - Orange - 01-02-26.pdf PDF
Attachment 8 - Site Visit Instructions.pdf PDF
Attachment 11 - Division Cost Breakdown.xlsx XLSX spreadsheet
Attachment 9 - PPQ.docx DOCX document
36C77626R0035.pdf PDF
Attachment 3 - Specs REV_02-26-2026.pdf PDF
Attachment 4 - PCRA and ICRA.pdf PDF
Attachment 7 - Limitations on Subcontracting - Construction.docx DOCX document
Show all 32

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

CD-A

500 CFM

CD-A

500 CFM

H-CRAC-2

ER-D

100 CFM

ER-D

80 CFM

ER-D

100 CFM

CD-A

90 CFM

CD-A

210 CFM

CD-A

210 CFM

CD-A

195 CFM

CD-A

195 CFM

CD-A

385 CFM

CD-A

385 CFM

CD-A

385 CFM

CD-A

385 CFM

CD-A

185 CFM

CD-A

180 CFM

H-CRAC-1

CD-A

125 CFM

CD-A

250 CFM

CD-A

50 CFM

ER-D

150 CFM

ER-D

100 CFM

RR-A

250 CFM

CD-A

330 CFM

CD-A

150 CFM

CD-A

85 CFM

CD-A

80 CFM

CD-A

150 CFM

CD-A

100 CFM

CD-A

300 CFM

CD-A

300 CFM

CD-A

400 CFM

CD-A

170 CFM

CD-A

80 CFM

CD-A

100 CFM

CD-A

170 CFM

CD-A

50 CFMCD-A

50 CFM

CD-A

150 CFM

CD-A

175 CFM

CD-A

175 CFM

CD-A

340 CFM

CD-A

330 CFM

CD-A

475 CFM

CD-A

475 CFM

CD-A

330 CFM

CD-A

340 CFM

CD-A

330 CFM

CD-A

80 CFM

CD-A

80 CFM

CD-A

80 CFM

CD-A

80 CFM

CD-A

80 CFM

CD-A

80 CFM

CD-A

80 CFM

CD-A

170 CFM

CD-A

170 CFM

CD-A

170 CFM

CD-A

100 CFM

CD-A

100 CFM

CD-A

100 CFM

CD-A

100 CFM

CD-A

100 CFM

CD-A

100 CFM

CD-A

180 CFM

CD-A

190 CFM

CD-A

190 CFM

CD-A

180 CFM

CD-A

180 CFM

CD-A

210 CFM

CD-A

210 CFM

SSR-A

410 CFM SSR-A

630 CFM

SRR-A

410 CFM

SRR-A

630 CFM

CD-A

195 CFM

CD-A

195 CFM

CD-A

150 CFM

CD-A

150 CFM

CD-A

150 CFM

CD-A

150 CFM

CD-A

80 CFM

CD-A

50 CFM

CD-A

140 CFM

CD-A

70 CFM CD-A

80 CFM

CD-A

100 CFM

CD-A

160 CFM

CD-A

90 CFM

CD-A

240 CFM

CD-A

120 CFM

CD-A

275 CFM

CD-A

160 CFM

CD-A

160 CFM

CD-A

185 CFM

CD-A

150 CFM

CD-A

175 CFM

CD-A

90 CFM

CD-A

90 CFM

CD-A

90 CFM

CD-A

90 CFM

CD-A

100 CFM

CD-A

460 CFM

CD-A

150 CFM

CD-A

145 CFM

CD-A

245 CFM

CD-A

245 CFM

ER-A

390 CFM

ER-A

340 CFM

ER-D

100 CFM

CD-A

240 CFM

RR-A

460 CFM

ER-D

100 CFM

ER-D

100 CFM

RR-A

150 CFM

RR-A

100 CFM

RR-A

330 CFM

ER-A

700 CFM RR-A

550 CFM

RR-A

100 CFM

RR-A

625 CFM

RR-A

625 CFM

RR-A

80 CFM

RR-A

80 CFM

RR-A

80 CFM

RR-A

80 CFM

RR-A

80 CFM

RR-A

80 CFM

RR-A

80 CFM

RR-A

900 CFM

RR-A

170 CFM

RR-A

350 CFM

RR-A

250 CFM

CD-A

100 CFM

CD-A

100 CFM

CD-A

100 CFM

RR-A

100 CFM

RR-A

100 CFM

RR-A

100 CFM

RR-A

380 CFM

RR-A

380 CFM

RR-A

160 CFM

RR-A

345 CFM

RR-A

390 CFM

ER-D

100 CFM

RR-A

770 CFM

RR-A

90 CFM

RR-A

90 CFM

RR-A

90 CFM

RR-A

90 CFM

ER-A

390 CFM

ER-A

390 CFM

ER-A

390 CFM

ER-D

120 CFM

ER-D

80 CFM

RR-A

150 CFM

RR-A

150 CFM

RR-A

150 CFM

RR-A

100 CFM

RR-A

140 CFM

RR-A

80 CFM

RR-A

50 CFM

RR-A

90 CFM

RR-A

120 CFM

CD-A

135 CFM

RR-A

135 CFM

RR-A

90 CFM

RR-A

340 CFM

RR-A

120 CFM

RR-A

150 CFM

14"x12"

12"x10"

10"x10" 12"x10"

10"x8"

CD-A

500 CFM

CD-A

500 CFM

18"x12"

CD-A

330 CFM

CD-A

330 CFM

CD-A

340 CFM

CD-A

330 CFM

18"x12"

CD-A

330 CFM

CD-A

340 CFM

CD-A

330 CFM

18"x12"

18"x12"

10"x10"

14"x14"

14"x12"

RR-A

340 CFM

8"x8"

8"x8"

CD-A

220 CFM

CD-A

220 CFM

CD-A

220 CFM

14"x14"

14"x14"14"x16"

RR-A

550 CFM

RR-A

340 CFM

16"x14"

RR-A

80 CFM

16"x14"

14"x12"

RR-A

250 CFM

12"x14"

14"x12"

ER-D

200 CFM

10"x10"

14"x12"

ER-A

700 CFM

ER-A

700 CFM

10"x10"

RR-A

100 CFM

RR-A

100 CFM

RR-A

100 CFM

RR-A

100 CFM

RR-A

625 CFM

RR-A

625 CFM

RR-A

100 CFM

RR-A

100 CFM

RR-A

100 CFM

CD-A

170 CFM

CD-A

170 CFM

RR-A

140 CFM

RR-A

340 CFM

RR-A

640 CFM

RR-A

85 CFM

10"x10" 12"x12"

RR-A

200 CFM

LFD-B

260 CFM

LFD-B

260 CFM

10"ø UP

16"x14"

16"x14"

10"ø

RR-A

50 CFM

10"x10"

10"x10"

RR-A

550 CFM

ER-A

300 CFM

12x12 UP

8"x10" 6"x6"

8"x12"

10"x12"

14x12 UP

12"x12"14"x14"

14x14 UP

10"x10"

10"x8"

"x

"x

10"x10"

10"x10" 10"x10"

8"x8"

6"x10"

"x

"x

12"x12"

12"x12"

16"x14"

10"x10"

10"x8"

6"x8"

10"x8"

14x14 UP

14"x14"

8"x10"

10"x10"

10"x10"

14"x14"8"x8"

10"x8"

8"x10"

12"x12"

8"x8" 8"x10"

8"x10"

8"x10" 8"x10"

8"x12"

RR-A

150 CFM

10"x10" 8"x8"

8"x8"

8"x10"

8"x8"

10"x10"

ER-A

240 CFM

RR-A

340 CFM

RR-A

340 CFM

10"x10"

10"x10"8"x10" 8"x10"

16"x14"

6"x8"

12"x12" 12"x12"

IMAGING RM

1K505c

C.T. (ED)

1E702

C.T. (ED)

1E702

RAD/FLOURO

1M710

RR-A

100 CFM

CD-A

150 CFM

H-MH-1.1FD4

H-MH-1.1FD1

H -M

H -1

.1 F

D

H -M

H -1

.1 F

D

H-MH-1.1FE1

H-MH-1.1FD4

10"x10"

EGG ROOM

1F106

CARDIAC NUC

1F309

8"x8"

12"x12"

8"x10"

6"x10"

12"x8"

16"x10"

16"x10"

12"x12"

10"x10"

8"x10"

8"x10"

8"x10"

8"x10"

10"x8"

8"x8"

6"x10"

12"x12"

6"x8"

10"x10"

8"x8"

363738394041

D.2 1.2

C

D

E

F

G

2.0

D.9

D.7

F.4

E.4

C.7

E.6

D.6

40.6 39.4 1.440.5

37.2

39.7

ER-A

390 CFM

RR-A

770 CFM

14"x16"

12"x12"

14"x16"

H-CRAC-12

H-CRAC-13

12"x12"

8"x12"

14"x12"

H-CRAC-14

RR-A

240 CFM

10"x10"

8"x8"

CD-A

120 CFM

14"x12"

10"x10"

10"x10"

12"x12"

12"x12"

10"x10"

14"x16"

14"x12"

14"x12"

CD-B

245 CFM

CD-B

245 CFM

CD-B

50 CFM

CD-A

140 CFM

RR-A

90 CFM

16"x14"

14"x14"

12"x12"

12"x12"

CD-A

260 CFM

CD-A

270 CFM

14"x12"

CD-A

185 CFM

CD-A

185 CFM

(TYP. OF 6)

(TYP. OF 6)

8"x6"

8"x6"

CD-A

150 CFM

RR-A

100 CFM

14"x14"

CD-A

150 CFMRR-A

100 CFM

14"x14"

14"x14"

10"x10"

CD-A

150 CFMRR-A

100 CFM

CD-A

185 CFM

12"x12"

STAIR

1ES04

NURSE

1F214

ECG CUBICLE

1F404

ECG: CUBICLE

1F408

ECG CUBICLE

1F406

PHYSICIAN

1F503

STAFF PHYSICIAN

1K802

STAFF PHYSICIAN

1K804

C.T. (#2)

1E605

PHYSICIAN

1F301

VEST

1F201

CHIEF NUC MED OFFICE

1K807

PROFESS NON-PHYSICIAN

1K805

STAFF PHYSICIAN

1K803

STRETCHER HOLD

1E301

RECEPTION

1K508

NUC MED WAIT

1K510

COMMON VIEWING RM

1K801

EQUIP

1KC06a

PASSAGE

1KC08

MRI CONTROL

1E204

CORRIDOR

1EC02

PET UPTAKE

1K210

UPTAKE

1K208

CONFERENCE

1A610a

STAFF PHYSICIAN

1K806

NURSE

1F210

NURSE

1F212

NURSE

1F204

NURSE

1F206

NURSE

1F208

CORRIDOR

1FC02

NURSE PRACTIONER

1K705

CLEAN SUPPLY

1K203

READING/CONSULT

1K502

PATIENT DOSE

1K205

THYROID UPTAKE

1K503

ENTRY

1K505

TECH WORK AREA

1K505d

CORRIDOR

1EC05

CORRIDOR

1EC03

CLEAN SUPPLY

1E604

MRI WAIT

1E501

RECEPTION

1E305

IV PREP

1E304

STORAGE

1E402

PET SIM UPTAKE

1K212

TREADMILL

1K504

CONTROL RM

1E603

UPTAKE

1K206

CORRIDOR

1KC02

BIO MED OFFICE

1M204

WAIT

1M702

CORRIDOR

1KC07

ELEC

1E610

DRESS

1E403

DRESS

1E401

CRASH CART

1E306

WHEELCHAIR & STRETCHER

WAITING

1E608

NOURISH

1A413

STAFF LKRS/LOUNGE

1A610

HAC

1A609

PHYSICIAN

1F501

NURSE

1F202

CORRIDOR

1FC05

C.T.

1E601

CORRIDOR

1EC06

CORRIDOR

1EC07

CHEST RM

1M206

ON-CALL ROOM

1A607

TLT

1K513

EXAM RM

1K509

CORRIDOR

1KC05

CORRIDOR

1KC06

STAFF TLT

1F402

CORRIDOR

1EC04

TLT

1E404

SOILED UTILITY

1A412

TLT

1K511

IV PREP

1K214a

MRI ROOM

1E202

MRI EQUIP

1E206a

NUC WASTE STOR

1K202

MRI CONTROL

1E302

IMAGING RM

1K505c

IMAGING RM

1K505a

IMAGING RM

1K505b

CORRIDOR

1MC02

SOILED HOLD

1K201

CORRIDOR

1EC01

COMM

1E608a

Drawing Title

Approved: Project Director

Project Title

Date

Location

Checked

Building Number

Project Number

Drawing Number

Drawn

Dwg.

CONSULTANTS: ARCHITECT/ENGINEERS:

OFFICE OF

FACILITIES

MANAGEMENT

o n e e ig h th i n c h o n e f o o t

B

A

C

D

E

F th re e i n c h e s o n e f o o t o n e a n d o n e h a lf i n c h e s o n e f o o t o n e i n c h o n e f o o t th re e q u a rt e rs i n c h o n e f o o t o n e h a lf i n c h o n e f o o t th re e e ig h th s i n c h o n e f o o t o n e q u a rt e r in c h o n e f o o t

VA FORM 08-6231, OCT 1978

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

A NEW HOSPITAL FOR

VAMC ORLANDO, FLORIDA

Orlando, Florida

673-950Professional Seals:

EB / RLF of04 JUNE, 2010

BUILDING IS FULLY SPRINKLERED

01 AND 02

HOSPITAL/CLINIC LEVEL 1, AREA D,

H-MH1.1FD4-A

ZONE 4 DUCTWORK PLAN

BID ALTERNATE NO. 3

PG/JI 2248

N

1/8" = 1'-0" GRAPHIC SCALE

4' 8' 24'16'

A1

C2

KEY PLAN

C1

D3

D4

E2

A2 A3

B1 B2

AREA D, ZONE 4

D2

D5 D6

E1 E3

D1

1 QUENCH VENT FROM MRI SYSTEM TO MRI

SHIELD PENETRATION TO BE PROVIDED BY MRI

VENDOR. CONTRACTOR TO PRIVIDE

INSULATION. FOR QUENCH VENT INSIDE RF

SHIELD, SEE SPECIFICATION SECTION 230711

FOR INSULATION REQUIREMENTS.

DRAWING NOTES

2 NOT USED.

FOR CONTINUATION UP, SEE H-MH-1.1ND4A.

GENERAL NOTES

3 PROVIDE RF WAVE FILTER AT DUCT

PENETRATION THROUGH RF SHIELD. PROVIDE

ALUMINUM DUCTWORK, DIFFUSERS AND

GRILLES INSIDE RF-SHIELD. COORDINATE RF

SHIELD PENETRATION LOCATION WITH RF

SHIELD MANUFACTURER.

No. Description Date

1 CPR 098 06/17/2011

2 CPR 122 09/16/2011

3 CPR 132 10/17/2011

4 CPR 236 03/09/2012

5 CPR 353 10/25/2012

6 CPR 382 03/15/2013

7 CPR 404 07/15/2013

2 2

2 2

2 2

4 OPEN END DUCT TO FLARE TO 24X14 WITH

NON METAL MESH SCREEN (1370 CFM).

5 42x12 EXHAUST GRILLE (1370 CFM).

6 CONNECT TO GRADIENT COIL EXHAUST

SYSTEM. COORDINATE WITH MRI EQUIPMENT

MANUFACTURER FOR EXACT LOCATION.

7 DUCT MOUNTED TEMPERATURE SENSOR.

8 NOT USED.

9 PROVIDE 12X12 ACCESS DOOR AT BOTTOM OF

DUCT FOR CLEANING ACCESS.

100 CFM

CD-A

340 CFM

CD-A

340 CFM

ER-A

950 CFM

RR-A

475 CFM

ER-A

135 CFM

ER-A

135 CFM

ER-A

135 CFM

ER-A

380 CFM

CD-A

200 CFM

CD-A

180 CFM

ER-C

310 CFM

CD-A

130 CFM

CD-A

185 CFM

CD-A

185 CFM

CD-A

80 CFM

CD-A

80 CFM

CD-A

125 CFM

CD-A

140 CFM

8"x10"

10"x10"

CD-A

240 CFM

CD-A

240 CFM

CD-A

70 CFM

CD-A

70 CFM

ER-A

850 CFM

CD-A

170 CFM

RR-A

170 CFM

CD-A

140 CFM

CD-A

155 CFM

CD-A

180 CFM

CD-A

190 CFM

CD-A

190 CFM

CD-A

175 CFM

CD-A

175 CFM

CD-A

180 CFM

CD-A

180 CFM

CD-A

210 CFM

CD-A

210 CFM

CD-A

140 CFM

CD-A

110 CFM

CD-A

170 CFM

CD-A

170 CFM CD-A

100 CFM

CD-A

340 CFM

CD-A

340 CFM

CD-A

100 CFM

CD-A

100 CFM

CD-A

100 CFM

CD-A

100 CFM

CD-A

100 CFM

CD-A

100 CFM

CD-A

100 CFM

CD-A

100 CFM

CD-A

100 CFM

CD-A

100 CFM

CD-A

100 CFM

CD-A

100 CFM

CD-A

200 CFM

CD-A

200 CFM

CD-A

180 CFM

CD-A

210 CFM

CD-A

140 CFM

CD-A

140 CFM CD-A

140 CFM

CD-A

180 CFM

CD-A

180 CFM

CD-A

180 CFM

CD-A

90 CFM

CD-A

90 CFM

CD-A

80 CFM

CD-A

80 CFM

CD-A

125 CFM

CD-A

125 CFM

CD-A

120 CFM

CD-A

120 CFM

CD-A

100 CFM

CD-A

180 CFM CD-A

110 CFM

CD-A

110 CFM

CD-A

110 CFM

CD-A

110 CFM

CD-A

225 CFM

CD-A

225 CFM

CD-A

225 CFM

CD-A

225 CFM

CD-A

225 CFM

CD-A

225 CFM

CD-A

225 CFM

CD-A

225 CFM

CD-A

225 CFM

CD-A

225 CFM CD-A

225 CFM

CD-A

225 CFM

CD-A

225 CFM

SSR-A

385 CFM

SSR-A

410 CFM

SRR-A

385 CFM

SRR-A

410 CFM

CD-A

150 CFM

CD-A

215 CFM

SRR-A

580 CFM SRR-A

520 CFM

SSR-A

580 CFM

SSR-A

520 CFM

CD-A

260 CFM

CD-A

90 CFM

CD-A

80 CFM

CD-A

100 CFM

CD-A

245 CFM

CD-A

130 CFM

ER-C

310 CFM

CD-A

460 CFM

CD-A

130 CFM

CD-A

230 CFM

RR-A

230 CFM

CD-A

80 CFM

RR-A

80 CFM

SRR-A

280 CFM

SSR-A

280 CFM

CD-A

80 CFM

RR-A

80 CFM

RR-A

80 CFM

CD-A

80 CFM

CD-A

140 CFMCD-A

140 CFM

RR-A

280 CFM

CD-A

300 CFM

RR-A

300 CFM

CD-A

300 CFM

CD-A

460 CFM

RR-A

100 CFM

RR-A

100 CFM

RR-A

100 CFM

RR-A

100 CFM

RR-A

100 CFM

RR-A

100 CFM

RR-A

100 CFM

RR-A

100 CFM

RR-A

100 CFM

RR-A

100 CFM

RR-A

100 CFM

RR-A

100 CFM

RR-A

700 CFM

RR-A

110 CFM

RR-A

80 CFM

RR-A

80 CFM

RR-A

100 CFM

RR-A

110 CFM

RR-A

100 CFM

RR-A

100 CFM

RR-A

80 CFM

RR-A

80 CFM

RR-A

210 CFM

RR-A

70 CFM

RR-A

90 CFM

RR-A

90 CFM

ER-A

100 CFM

ER-A

270 CFM

ER-A

270 CFM

ER-A

160 CFM

ER-A

160 CFM

ER-A

160 CFM

ER-D

100 CFM

RR-A

340 CFM

RR-A

590 CFM

RR-A

590 CFM

RR-A

200 CFM

RR-A

215 CFM

CD-A

100 CFMCD-A

110 CFM

CD-A

110 CFM

CD-A

100 CFM

CD-A

80 CFM

CD-A

375 CFM

CD-A

375 CFM

RR-A

740 CFM

ER-D

100 CFM

CD-A

50 CFM

CD-A

160 CFM

ER-D

100 CFM

ER-D

100 CFM

ER-D

250 CFM

ER-D

170 CFM

ER-A

390 CFM

ER-A

340 CFM

ER-D

100 CFM

RR-A

100 CFM

RR-A

80 CFM

RR-A

90 CFM

RR-A

350 CFM

RR-A

350 CFM

ER-D

100 CFM

ER-D

100 CFM

CD-A

100 CFM

RR-A

380 CFM

RR-A

380 CFM

CD-A

160 CFM

RR-A

160 CFM

RR-A

110 CFM

RR-A

480 CFM

RR-A

345 CFM

RR-A

210 CFM

RR-A

210 CFM

CD-A

135 CFM

RR-A

135 CFM

CD-A

80 CFM

CD-A

100 CFM

RR-A

140 CFM

CD-A

285 CFM

CD-A

285 CFM

CD-A

110 CFM

CD-A

90 CFM

CD-A

215 CFM

CD-A

215 CFM

CD-A

235 CFM

CD-A

235 CFM

CD-A

235 CFM

CD-A

150 CFM

RR-A

700 CFM

10"x10"

10"x10"

16"x14"

CD-A

100 CFM

CD-A

325 CFM

CD-A

475 CFM

14"x12"

CD-A

215 CFM

CD-A

215 CFM

10"x10"

12"x12"

ER-D

100 CFM

ER-D

100 CFM

ER-D

230 CFM

ER-A

475 CFM

ER-A

425 CFM

ER-D

100 CFM

14"x14" 14"x14"

14"x14"

12"x12"

10"x10"

14"x14"

RR-A

590 CFMRR-A

590 CFM

CD-A

190 CFM

CD-A

190 CFM

14"x12"

10"x10"

14"x16"

CD-A

180 CFM

RR-A

50 CFM

14"x14"

10"x10"

CD-A

220 CFM

CD-A

220 CFM

14"x14"

14"x14"

14"x14"

RR-A

160 CFM

RR-A

125 CFM

RR-A

140 CFM

14"x14"

10"x8"

CD-A

100 CFM

CD-A

50 CFM

CD-A

70 CFM

12"x12"

16"x14"

16"x14"

12"x12"

6"x6" 12"x12"

RR-A

1390 CFM

RR-A

1390 CFM

RR-A

100 CFM

ER-D

100 CFM

TG-A

1000 CFM

RR-A

590 CFM RR-A

70 CFM

8"x8"

16x14 UP 16x14 UP

14"x14" 14"x10"

12"x10"

12"x10"

10"x10"

14"x14"

CD-A

75 CFM

8"x8"

12"x12" 10"x10"

12"x10"

10"x10"10"x10"

14"x14"8"x8"

8"x10"

12"x12"

8"x8" 8"x10"

8"x10"

CD-A

150 CFM

CD-A

100 CFM

14"x16"

8"x8"

16"x14"

14"x12"

8"x10"

8"x8"

12"x10"

14"x12"

14"x14"

RR-A

340 CFM

RR-A

340 CFM

10"x10" 10"x10"

10"x10"8"x10" 8"x10"

10"x10"

6"x10" 12"x10"

10"x12"

10"x10"

6"x10"

8"x8"

8"x8"

14"x8"

10"x10" 10"x10"

6"x10"

6"x10"

6"x8"

14"x12"

14"x12" 10"x12"

10"x10"

12"x12"

12"x10"

10"x8"

8"x8"

4"x8" 10"x8"

6"x8"

10"x8"

12"x10"8"x10"

4"x10"

6"x10"

12"x12"

8"x10"8"x10"

16"x12"

12"x10"

8"x10"

6"x10"

10"x14"10"x12"

6"x12"

10"x14"

12"x12" 12"x12"

12"x10"

12"x12" 12"x12"

12"x12"

10"x10"

6"x8"

12"x12"

14"x14"

12"x10"

18"x16"

Unoccupied

Unoccupied

CONTROL

1M111a

RAD/FLOURO

1M710

CONTROL

1M710a

TRAINING ROOM

1C114

MAIL ROOM

1C112a

CLOSET

1C106

CLOSET

1C104

PASSAGE

1C112

TESTING RM

1C110

CORRIDOR

1CC01

HAC

1C108

F/D

H-MH-1.1FD5

H-MH-1.1FD2

H -M

H -1

.1

FD

H -M

H -1

.1

FD

1 H -M

H -1

.1

FD

H -M

H -1

.1

FD

H-MH-1.1FE2

H-MH-1.1FD5

H-MH-1.1FD5

H-MH-1.1FD2

WAITING/LOUNGE

1G101

EGG ROOM

1F106

STRESS LAB

1F607

ECHO ROOM

ECG/ECHO

1F601

CARDIOLOGY

1M715

CARDIAC NUC

1F309

ELEVATOR

LOBBY

1F716

STORAGE

1G410

SECRETARY

1G402

CHIEF

1G403

POLICE

TRAINING

1h206

LOCKERS

FEMALE

1G303a

RETAIL

STORAGE

1G304

OFFICE

1N204

OFFICE

N203

OFFICE

1N404

OFFICE

1N403

OFFICE

1N201

OFFICE

1N202

OFFICE

1N405

ADMIN

1N401

OFFICE

1N205

OFFICE

1N206

CANTEEN

RETAIL

1N601

CONFERENCE

1M708

EMPLOYEE

1M307

OFFICE

1M402

SECRETARY

1M717

COMM

1M403 ELEC

1M307A

ELEC

1N601A

COMM

1N601B

12"x12"

10"x10"

10"x10"

14"x14"

8"x10"

8"x10"

8"x10"

12"x12"

14"x14"

12"x12"

29303136

D.2 D.1

1.2 8.1

C

D

E

F

G

D.7

F.4

E.4

C.7

32333435 A7

7.7

33.6

12"x14"

RR-A

100 CFM

RR-A

100 CFM

8"x8"

CD-A

135 CFM

8"x8"

10"x10"

12"x12"

12"x12"

12"x10"12"x10"

12"x12"

6"x8"

F/D

6"x6"

6"x6"

14"x14"

12"x12"

12"x12"

CD-A

260 CFM

CD-A

270 CFM

14"x12"

CD-A

60 CFM

Drawing Title

Approved: Project Director

Project Title

Date

Location

Checked

Building Number

Project Number

Drawing Number

Drawn

Dwg.

CONSULTANTS: ARCHITECT/ENGINEERS:

OFFICE OF

FACILITIES

MANAGEMENT

on e ei gh th in ch o ne f oo t

B

A

C

D

E

F th re e in ch es o ne f oo t

6"

6" on e an d on e ha lf in ch es o ne f oo t on e in ch o ne f oo t

6" 6" th re e qu ar te rs in ch o ne f oo t on e ha lf in ch o ne f oo t th re e ei gh th s in ch o ne f oo t on e qu ar te r in ch o ne f oo t

VA FORM 08-6231, OCT 1978

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

A NEW HOSPITAL FOR

VAMC ORLANDO, FLORIDA

Orlando, Florida

673-950Professional Seals:

EB / RLF of04 JUNE, 2010

BUILDING IS FULLY SPRINKLERED

01 AND 02

HOSPITAL/CLINIC LEVEL 1, AREA D,

H-MH1.1FD5-A

ZONE 5 DUCTWORK PLAN

BID ALTERNATE NO. 3

PG/JI 2250

N

1/8" = 1'-0" GRAPHIC SCALE

4' 8' 24'16'

A1

C2

KEY PLAN

AREA D, ZONE 5

C1

D3

D4

E2

A2 A3

B1 B2

D2

D5 D6

E1 E3

D1

FOR CONTINUATION UP, SEE H-MH-1.1ND5A.

GENERAL NOTES

No. Description Date

2 CPR 098 06/17/2011

3 CPR 068 07/08/2011

4 CPR 122 09/16/2011

5 CPR 160 10/14/2011

6 CPR 132 10/17/2011

7 CPR 236 03/09/2012

8 CPR 272 04/30/2012

9 CPR 353 10/25/2012

340 CFM

CD-A

340 CFM

CD-A

185 CFM

CD-A

185 CFM

ER-A

850 CFM

CD-A

185 CFM

CD-A

340 CFM

CD-A

340 CFM

CD-A

185 CFM

CD-A

185 CFM

CD-A

185 CFM

CD-A

185 CFM

CD-A

140 CFM

CD-A

140 CFM

CD-A

180 CFM

CD-A

180 CFM

RR-A

650 CFM

CD-A

285 CFM

CD-A

90 CFM

CD-A

90 CFM

CD-A

150 CFM

CD-A

215 CFM

CD-A

120 CFM

CD-A

215 CFM

CD-A

235 CFM

CD-A

235 CFM

CD-A

235 CFM

CD-A

150 CFM

CD-A

150 CFM

SSR-A

420 CFM

SSR-A

500 CFM

CD-A

150 CFM

CD-A

150 CFM

CD-A

150 CFM

CD-A

80 CFM

CD-A

110 CFM

CD-A

110 CFM

CD-A

245 CFM

CD-A

245 CFM

CD-A

70 CFM

CD-A

160 CFM

CD-A

160 CFM

CD-A

475 CFM

CD-A

475 CFM

CD-A

225 CFM

CD-A

225 CFM

CD-A

300 CFM

16"x14"

CD-A

100 CFM

CD-A

325 CFM

CD-A

475 CFM

CD-A

215 CFM

CD-A

215 CFM

10"x10"

CD-A

300 CFM

CD-A

300 CFM

12"x12"

ER-D

100 CFM

ER-A

600 CFM

ER-D

100 CFM

ER-D

230 CFM

ER-A

475 CFM

ER-A

425 CFM

ER-D

100 CFM

14"x14"

14"x14"

14"x14"

RR-A

650 CFM

CD-A

100 CFM CD-A

200 CFM

10"x14"

ER-D

100 CFM

CD-A

100 CFM

SSR-A

370 CFM

SSR-A

390 CFM

CD-A

100 CFM

RR-A

100 CFM

16"x14"

SRR-A

370 CFM

SRR-A

390 CFM

RR-A

1390 CFM

RR-A

1390 CFM

AISLE

1PC01

CLEANING EQUIP

1P606

STOR

1H107b

UNIFORM DISTRIBUTION

1H305

MANIFOLD RM

1H307

MANIFOLD ROOM

1H309

PATH OFFICE

1H608

VIEWING

1H407

DIET TECHS

1PC01b

TRAY CART

1V701

CHIEF FNS

1P107

NUTRITION THERAPY

1P105 SANITARY SUPPLY

1P602

SECRETARY/WAIT

1PC01a

PROGRAM MANAGER

1P103

OFFICE

1H107a

TRAY ASSEMBLY

1V702

RECEIVING OFFICE

1V712a

RECEIVING

1V712

RETHERM

1V708

BULK CARTS STAGING

1V802

COLD ROOM

1H407a

CORRIDOR

1PC06

HAC

1P608

BULK REFRIGERATED

STORAGE

1V803

CART/CAN WASH

1P601a

EXTRACTOR

1V721

DISHWASH

1P601

SANITARY SUPPLY

1P601c

CLEAN DISH STORAGE

1P601b

AUTOPSY

1H601

TLT/SHWR

1H603

TLT/SHWR

1H605

PASSAGE

1HC06

SPECIMEN STOR

1H105

CORRIDOR

1HC01

COMM

1V705

COORDINATION CENTER

1PC01c

CHIEF CANTEEN

1P106

ELEC

1V703

CORRIDOR

1VC09

CORRIDOR

1HC05

COMM

1H916

BIO MED ENGINEERING REPAIR

1H107

OFFICE

1H107c

PUMP ROOM

1H301

UNIFORM DROP

1H311

ELEV LOBBY

1PC06a

CORRIDOR

1HC03

MEAL CARTS/REFRIGERATOR

1V704

BIO MED ENGINEERING REPAIR

1H107

STG-A

420 CFM

RR-A

100 CFM

RR-A

100 CFM

TG-A

1000 CFM CD-A

185 CFM

CD-A

185 CFM

RR-A

370 CFM

STG-A

500 CFM

12"x8" 12"x8"

16x14 UP 16x14 UP

14"x14" 14"x10"

12"x10"

CD-A

190 CFM

CD-A

190 CFM

RR-A

280 CFM

CD-A

50 CFM

RR-A

160 CFM

CD-A

160 CFM

CD-A

250 CFM

CD-A

250 CFM

10"x10"

16"x14"

10"x14"

10"x10"

14"x16"

10"x14"

ELEC

1H918

10"x10"

12"x12"

12"x14"

10"x10"

6"x10"

16"x14"

8"x10"

CD-A

50 CFM

14"x16"

10"x12"

8"x10"

12"x12"

8"x10"10"x10"6"x10"

12"x12"

12"x10"

14"x16" 10"x12" 10"x12"

18"x16"

ER-D

120 CFM

8"x8"

ER-D

150 CFM

12"x10" 10"x10"

12"x12"

12"x12" 12"x12"

CD-A

280 CFM

CD-A

280 CFM

12"x12"

SER-A

400 CFM

8"x14"1

8"x14"1

SER-A

400 CFM

H-MH-1.1FD6

H-MH-1.1FD3

H -M

H -1

.1

FD

H -M

H -1

.1

FD

H-MH-1.1FE3

H-MH-1.1FD6

F/D

10"x10"10"x10"

SERVICE ENTRANCE PIT

F/D

F/D

16"x14"

10"x10"

8"x10"

14"x14" 12"x12"

12"x12"

8"x8"

14"x10"

12"x10"

14"x8"

26272829

C

D

E

F

G

D.7

F.4

E.4

C.7

B.7

26.427.7

E.5

H-EF-42

H-EF-41

STG-A

400 CFM

F/D

12"x12"

10"x10"

12"ø

12"x14"

Drawing Title

Approved: Project Director

Project Title

Date

Location

Checked

Building Number

Project Number

Drawing Number

Drawn

Dwg.

CONSULTANTS: ARCHITECT/ENGINEERS:

OFFICE OF

FACILITIES

MANAGEMENT

on e ei gh th in ch o ne f oo t

B

A

C

D

E

F th re e in ch es o ne f oo t

6"

6" on e an d on e ha lf in ch es o ne f oo t on e in ch o ne f oo t

6" 6" th re e qu ar te rs in ch o ne f oo t on e ha lf in ch o ne f oo t th re e ei gh th s in ch o ne f oo t on e qu ar te r in ch o ne f oo t

VA FORM 08-6231, OCT 1978

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

A NEW HOSPITAL FOR

VAMC ORLANDO, FLORIDA

Orlando, Florida

673-950Professional Seals:

EB / RLF of04 JUNE, 2010

BUILDING IS FULLY SPRINKLERED

01 AND 02

HOSPITAL/CLINIC

H-MH1.1FD6

LEVEL 1, AREA D, ZONE 6

DUCTWORK PLAN

PG/JI 2251

N

1/8" = 1'-0" GRAPHIC SCALE

4' 8' 24'16'

A1

C2

KEY PLAN

C1

D3

D4

E2

A2 A3

B1 B2

D2

D5 D6

E1 E3

D1

AREA D, ZONE 6

FOR CONTINUATION UP, SEE H-MH-1.1ND6.

GENERAL NOTES

1 INSTALL LOW EXHAUST GRILLE 1'-0" FROM

FLOOR.

DRAWING NOTES

2 24"x72"x24" PLENUM. CONNECT TO LOUVER.

BLANK OFF UNUSED PORTION OF THE LOUVER.

No. Description Date

1 CPR 023R1 02/25/11

2 CPR 230 02/23/2012

3 CPR 293 06/08/2012

4 CPR 353 10/25/2012

3 24"x36"x24" PLENUM. CONNECT TO LOUVER.

BLANK OFF UNUSED PORTION OF THE LOUVER.

4 24"x36" LOUVER OPEN TO MANIFOLD ROOM

1H307. BLANK OFF REMAINDER OF LOUVER.

5 12" ROUND WELDED STAINLESS STEEL DUCT

TO BE INSTALLED BELOW GRADE (CONCRETE

ENCASED). CONNECT TO AUTOPSY TABLE

DOWNDRAFT EXHAUST SYSTEM (700 CFM).

COORDINATE WITH AUTOPSY TABLE

MANUFACTURER REQUIREMENTS. SAWCUT

SLAB ON GRADE AS NEEDED TO INSTALL

UNDER-SLAB DUCT. SEE DETAIL ON H-AE5.424.

RESTORE SLAB VAPOR-BARRIER CONTINUITY.

H-FCU-1.7

H-FCU-1.10

14"x14"

10"ø 14"x12"

10"ø

12"x14"

10"x12"

10"x10"

10"x12"

12"x10"

8"x10"

16"x16"

20"x18"18"x12"

12"x18"

18"x12"

14"x14"

H-TU-7.16

H-TU-7.12

H-TU-7.10

H-TU-7.13

H-TU-7.11H-TU-7.7

H-TU-7.6

H-TU-7.8

H-TU-7.15

H-TU-7.5

H-TU-7.17

H-TU-7.9

14"x12"

10"x10"

10"x10"

12"x12"10"x10"

14"x12"

10"x10"

10"x8"

H-TU-9.18

H-TU-9.15

H-TU-9.20

H-TU-9.13

H-TU-9.9

H-TU-9.11

H-TU-9.10

H-TU-9.19

H-TU-9.17

H-TU-9.31

H-TU-9.12

H-TU-9.21 H-TU-9.23

H-TU-9.4

H-TU-9.5

H-TU-9.22

H-TU-9.8

H-TU-9.1

H-TU-9.16

10"x10"

8"x8"

8"x8"

16"x20"

20"x20"

14"x12"

14"x12"

14"x16"

H-TU-8.12

H-LEF-11

6" EA FROM H-LEF-11

UP THRU ROOF

30"x16"

32"x28" 54"x34"

H-TU-9.27

H-TU-8.26

"x

10"ø

14"x14"

H-TU-7.18

H-TU-9.14

10"ø

14"x14"

8"x10"

H-EF-37

H-EF-38

40"x34"

38"x24"

40"x26"

18"x12"

12"x12"

18"x16"

12"x12"

36"x24"

14"x12"

12"x14"

12"x12"

8"x8"

12"x10"

18"x12"

30"x20"

24"x20"

20"x16"

16"x14"

14"x12"

18"x18"

16"x14"

18"x12"

SSR-A

320 CFM

SSR-A

320 CFM

SSR-A

320 CFM

SSR-A

320 CFM

10"x10"

16"x14" 14"x14"

8"x8"

"x

34"x20" 22"x16"

16"x14"

16"x14"

10"x10"10"x8"

20"x20" 8"x8"

14"x14"

14"x14"

10"x8"

F/D

14"x12"

14"x14"

SSR-A

320 CFM

SSR-A

320 CFM

SSR-A

315 CFM

SSR-A

320 CFM

12"x10"

12"x10" 12"x10"

12"x10"

F/D F/D

H-MH-1.1NE2

H-MH-1.1ND5

H -M

H -1

.1 N

D A

H -M

H -1

.1 N

D A

H-MH-1.1ND4A

H-MH-1.1ND1

"x

3738394041

C

D

E

F

G

D.9

D.7

F.4

E.4

C.7

E.6

D.6

40.6 39.440.5

37.2

39.7

12"ø

14"x16"

12"x12"

20"x18"

14"x16"

12"x12"

12"x12"

14"x14"

12"x14"

12"x14"

8"x10"

8"x10"

8"x8"

8"x8"

8"x8"

8"x8"

8"x8"

10"x12" 10"x10" 10"x10"

10"x10"

8"x8"

10"x10"

8"x8"8"x8"

6"x6"

6"x6"

6"x6"

8"x8"

14"x12"

10"x10"

18"x12"

1 2

1 2

10"x10"

16"x14" 16"x14"

16"x14" F/D

F/D

F/D

14"x14"

7 8"ø6

12"ø

Drawing Title

Approved: Project Director

Project Title

Date

Location

Checked

Building Number

Project Number

Drawing Number

Drawn

Dwg.

CONSULTANTS: ARCHITECT/ENGINEERS:

OFFICE OF

FACILITIES

MANAGEMENT

o n e e ig h th i n c h o n e f o o t

B

A

C

D

E

F th re e i n c h e s o n e f o o t o n e a n d o n e h a lf i n c h e s o n e f o o t o n e i n c h o n e f o o t th re e q u a rt e rs i n c h o n e f o o t o n e h a lf i n c h o n e f o o t th re e e ig h th s i n c h o n e f o o t o n e q u a rt e r in c h o n e f o o t

VA FORM 08-6231, OCT 1978

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

A NEW HOSPITAL FOR

VAMC ORLANDO, FLORIDA

Orlando, Florida

673-950Professional Seals:

EB / RLF of04 JUNE, 2010

BUILDING IS FULLY SPRINKLERED

01 AND 02

HOSPITAL/CLINIC LEVEL 1, AREA D,

H-MH1.1ND4-A

ZONE 4 INTERSTITIAL DUCTWORK PLAN

BID ALTERNATE NO. 3

PG/JI 2270

N

1/8" = 1'-0" GRAPHIC SCALE

4' 8' 24'16'

A1

C2

KEY PLAN

C1

D3

D4

E2

A2 A3

B1 B2

AREA D, ZONE 4

D2

D5 D6

E1 E3

D1

PROVIDE WIRE MESH OVER RETURN AIR

OPENING OF ALL FAN COIL UNITS.

GENERAL NOTES

No. Description Date

1 CPR 122 09/16/2011

2 CPR 236 03/09/2012

3 CPR 404 07/15/2013

1 2'-0" X 2'-0" OVERPRESSURE RELIEF DUCT TO

GOOSENECK ON ROOF.

DRAWING NOTES

2 PROVIDE RF WAVE FILTER AT DUCT

PENETRATION THROUGH RF SHIELD. PROVIDE

ALUMINUM DUCTWORK, DIFFUSERS AND

GRILLES INSIDE RF SHIELD. COORDINATE RF

SHIELD PENETRATION LOCATION WITH RF

SHIELD MANUFACTURER.

4 PROVIDE 2 mm DRAINAGE HOLE. INSULATION

SHALL NOT COVER DRAINAGE HOLE. PROVIDE

LABEL CLOSE TO BURST DISK INDICATING

QUANTITY AND LOCATION OF DRAIN HOLE.

3 CONTRACTOR TO PROVIDE QUENCH VENT

PIPE FROM WAVE GUIDE TO GOOSE NECK ON

ROOF. QUENCH VENT PIPE SHALL BE ALL

WELDED 18 GAGE STAINLESS STEEL DUCT.

CONTRACTOR TO PROVIDE INSULATION FOR

ALL QUENCH VENT PIPE (FROM MRI UNIT TO

GOOSENECK). SEE SPECIFICATION SECTION

230711 FOR INSULATION REQUIREMENTS AND

REFER TO PHILIPS SD VAMC-0019 FOR QUENCH

PIPE AND VENT REQUIREMENTS.

5 WAVE GUIDE TO BE PROVIDED BY MRI VENDOR

AND INSTALLED BY CONTRACTOR. INSTALL

WAVE GUIDE SHORT SIDE UP. LONG SIDE OF

WAVE GUIDE SHALL BE INSIDE RF SHIELD.

6 PROVIDE EXHAUST DIFFUSER WITH MINIMUM

OF 10" TRANSITION LENGTH.

7 WAVE GUIDE TO BE PROVIDED BY MRI VENDOR

AND INSTALLED BY CONTRACTOR. INSTALL

WAVE GUIDE LONG SIDE UP. SHORT SIDE OF

WAVE GUIDE SHALL BE INSIDE RF SHIELD.

34"x30"

46"x34"

24"x16"

58" x 36" UP

TO AHU-8

26"x20" UP

TO EF-8

14"x12"

14"x14"

12"x12"

12"x10"

H-TU-29.5

H-TU-29.1

H-TU-29.2

H-FCU-1.4

10"x10"

8"x10"

14"x14"

10"x10"

10"x10"

12"x10"

10"x8"

10"x8"

H-TU-9.6

H-TU-9.23

H-TU-9.25

H-TU-9.26

H-TU-9.24

H-TU-9.4

H-TU-9.7

H-TU-9.5

H-TU-9.3

H-TU-9.1

H-TU-9.2

12"x12"

14"x12"

14"x14"12"ø

12"x12"

10"x10"

14"x14"

28"x18"

26"x20"

24"x16"

10"x8"

14"x12"

12"x10"

12"x12"

10"x8"

10"x10"

12"x10"

14"x8"

SSR-A

375 CFM

SSR-A

375 CFM

SSR-A

375 CFM

18"x18"

12"x12"

12"ø

14"x14"

SRR-A

1280 CFM

SRR-A

1280 CFM

12"x12"

16"x14"

10"x10"

14"x14"

H-TU-8.1 H-TU-9.30

H-TU-8.3

H-TU-8.4

H-TU-8.5

H-TU-8.6

H-TU-8.7

H-TU-8.12

H-TU-8.9

H-TU-8.10H-TU-8.11

H-TU-8.8

H-TU-8.13

H-TU-4.7

H-TU-4.10

H-TU-4.11

H-TU-4.13

H-TU-4.6

H-TU-4.5

H-TU-4.12

H-TU-4.9

H-TU-4.8

H-TU-4.2

H-TU-4.3

H-TU-4.4

H-TU-4.1

H-TU-4.17

H-TU-4.15

H-TU-4.14

H-TU-4.16

24"x20"

20"x16"

14"x14"

H-TU-9.28

H-TU-8.26

50"x34"

12"ø

10"x12"

SER-A

530 CFM

36"x24" 36"x24"46"x30"

H-TU-9.29

44"x38" UP

TO AHU-8

10"x10"

H-F/SD-7

H-F/SD/8

H-F/SD-9

H-F/SD-10

H-F/SD-11 H-F/SD-14

H-F/SD-15

H-F/SD-12

H-F/SD-13

H-F/SD-23

H-F/SD-22

H-F/SD-26

H-F/SD-25

H-F/SD-24

"x

12"x10"

12"x12"

8"x8"

16"x14"

12"x12"

16"x14"

22"x16"

H-TU-8.28H-TU-8.29

14"x14"

16"x14"

"x

"x

"x

12"x12"

8"x10"

6"x8"

12"ø

12"ø

14"x14"

12"x8"

12"x8"

"x

8"x10" 8"x10"

18"x16"

"x

14"x14"

"x

34"x24"

H-F/SD-27

H-FCU-1.13

24"x10"

12"x8"

SSR-A

425 CFM

ANZ-B

680 CFM

ANZ-B

680 CFM

ANZ-B

680 CFM

ANZ-B

680 CFM

ANZ-B

680 CFM

26"x20"

26"x20"

16"x12"

12"x14"

12"x12"

10"x10"

24"x18"

16"x10"SSR-A

210 CFM

SSR-A

210 CFM

SSR-A

210 CFM

12"x8"12"x8"

36"x24"

12"x12" 42"x36"

24"x14"

46"x34"

12"x10"

34"x30"

10"x8"

14"x16"

44"x38"

10"x10"

38"x24"

10"x10"

20"x20"

14"x14"

14"x16" 12"x12"

F/D

F/DF/DF/D

F/D

F/D

38"x24" 58"x36"

12"x12"

18"x18" 26"x20"

20"x16"

34"x30"

22"x8"

10"x10"

12"x12"

50"x34"

12"ø 12"ø

16"x14"

52"x30"

30"x18" 16"x14" 16"x14"

14"x12"

10"x10"

14"x14"

10"x10"

12"x12"

F/D

F/D

F/D

F/D

F/D

18"x12"

H-FCU-1.6

SSR-A

320 CFM

SSR-A

320 CFM

SSR-A

320 CFM

SSR-A

315 CFM

12"x10"

12"x10"

12"x10"

12"x12"

8"x10"

30"x16"

F/D F/D

F/D F/D F/D

F/D

F/D

F/D

16"x10"

F/D

14"x14"

H-MH-1.1NE2A

H-MH-1.1ND5A

H -M

H -1

.1 N

D A

H -M

H -1

.1 N

D A

H-MH-1.1ND5A

H-MH-1.1ND2A

H -M

H -1

.1 N

D

H -M

H -1

.1 N

D A

303136

C

D

E

F

G

D.7

F.4

E.4

C.7

32333435 A7

C.81

C.91

33.6

8"x8"

H-TU-4.35

H-TU-4.18

14"x12"

10"x10"

14"x14"

12"x12"

10"x10" 10"x10"

12"x12"

12"x12"

6"x6"

6"x6"

10"x14"

F/D

Drawing Title

Approved: Project Director

Project Title

Date

Location

Checked

Building Number

Project Number

Drawing Number

Drawn

Dwg.

CONSULTANTS: ARCHITECT/ENGINEERS:

OFFICE OF

FACILITIES

MANAGEMENT

o n e e ig h th i n c h o n e f o o t

B

A

C

D

E

F th re e i n c h e s o n e f o o t o n e a n d o n e h a lf i n c h e s o n e f o o t o n e i n c h o n e f o o t th re e q u a rt e rs i n c h o n e f o o t o n e h a lf i n c h o n e f o o t th re e e ig h th s i n c h o n e f o o t o n e q u a rt e r in c h o n e f o o t

VA FORM 08-6231, OCT 1978

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

A NEW HOSPITAL FOR

VAMC ORLANDO, FLORIDA

Orlando, Florida

673-950Professional Seals:

EB / RLF of04 JUNE, 2010

BUILDING IS FULLY SPRINKLERED

01 AND 02

HOSPITAL/CLINIC LEVEL 1, AREA D,

H-MH1.1ND5-A

ZONE 5 INTERSTITIAL DUCTWORK PLAN

BID ALTERNATE NO. 3

PG/JI 2272

N

1/8" = 1'-0" GRAPHIC SCALE

4' 8' 24'16'

A1

C2

KEY PLAN

AREA D, ZONE 5

C1

D3

D4

E2

A2 A3

B1 B2

D2

D5 D6

E1 E3

D1

PROVIDE WIRE MESH OVER RETURN AIR

OPENING OF ALL FAN COIL UNITS.

GENERAL NOTES

1 SUPPLY DUCT TO RUN BELOW THE SECOND

FLOOR BRIDGE.

DRAWING NOTES

2 PROVIDE 2 HR FIRE RATED DUCT WRAP.

3 30X36 SA FROM H-AHU-29

4 NOT USED

6 50X34 SA FROM H-AHU-9

7 20X20 EA TO H-EF-9

8 20X26 EA TO H-EF-4

9 30X40 RA TO H-AHU-29

5 64X34 RA TO H-AHU-9

No. Description Date

1 CPR 023R1 02/25/11

2 CPR 068 07/08/2011

3 CPR 122 09/16/2011

4 CPR 160 10/14/2011

5 CPR 382 03/15/2013

H-TU-5.23H-TU-5.21

H-TU-5.17

H-TU-5.18 H-TU-5.19

H-TU-5.20

H-TU-5.22

H-TU-5.26 H-TU-5.24

H-TU-5.25

16"x14"

H-TU-3.4

14"x12"

H-TU-3.3

H-TU-3.2

10"x10"

12"x12"H-TU-3.1

12"x14"

12"ø

12"x12"

10"x10"

10"x8"

12"x12"

12"x8" 12"x8"

24"x18"

24"x4"

24"x4"

12"x12"

22"x18"32"x18"

H-TU-4.29

H-TU-4.30

H-TU-4.31

H-TU-4.32

H-TU-4.33

36"x24"

24"x16"

52"x30" 48"x24"

40"x24"

H-FCU-1.16

H-TU-4.34

14"x14"

10"x10"

12"x12"

12"x12"

14"x16"

18"x16"

14"x14"

6"x10"

16"x14"

14"x10"

12"x12"

10"x12"

14"x12"

14"x16" 10"x12"

14"x14"

12"x12"

12"x10"

16"x14"

SSR-A

210 CFM

SSR-A

210 CFM

SSR-A

210 CFM

SSR-A

205 CFM

16"x10"

12"x8"

12"x8"

12"x8"

12"x8"

SSR-A

320 CFM

14"x6"

18"x12"

12"x8"

12"x8"

SSR-A

210 CFM

SSR-A

205 CFM

SSR-A

210 CFM

12"x8"12"x8"

SSR-A

210 CFM

10"x10"

8"x8"

SSR-A

320 CFM

14"x6"

SSR-A

320 CFM

14"x6"

SSR-A

320 CFM

14"x6"

12"x12"

H-TU-5.27

14"x14"

16"x14"

16"x14"

16"x14"

28"x18"

16"x14" 16"x14"

14"x14"

14"x14"

24"x16"

16"x10"

"x

H -M

H -1

.1 N

D

H -M

H -1

.1 N

D

H-MH-1.1ND6

H-MH-1.1ND3

2627282930

C

D

E

F

G

D.7

F.4

E.4

C.7

26.427.7

E.5

12"x10"

H-EF-44

ø18"ø12"

2627282930

C

D

E

F

G

30.2

D.7

F.4

E.4

C.7

26.427.7

E.5

Drawing Title

Approved: Project Director

Project Title

Date

Location

Checked

Building Number

Project Number

Drawing Number

Drawn

Dwg.

CONSULTANTS: ARCHITECT/ENGINEERS:

OFFICE OF

FACILITIES

MANAGEMENT

o n e e ig h th i n c h o n e f o o t

B

A

C

D

E

F th re e i n c h e s o n e f o o t o n e a n d o n e h a lf i n c h e s o n e f o o t o n e i n c h o n e f o o t th re e q u a rt e rs i n c h o n e f o o t o n e h a lf i n c h o n e f o o t th re e e ig h th s i n c h o n e f o o t o n e q u a rt e r in c h o n e f o o t

VA FORM 08-6231, OCT 1978

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

A NEW HOSPITAL FOR

VAMC ORLANDO, FLORIDA

Orlando, Florida

673-950Professional Seals:

EB / RLF of04 JUNE, 2010

BUILDING IS FULLY SPRINKLERED

01 AND 02

HOSPITAL/CLINIC

H-MH1.1ND6

LEVEL 1, AREA D, ZONE 6

INTERSTITIAL DUCTWORK PLAN

PG/JI 2273

N

1/8" = 1'-0" GRAPHIC SCALE

4' 8' 24'16'

A1

C2

KEY PLAN

C1

D3

D4

E2

A2 A3

B1 B2

D2

D5 D6

E1 E3

D1

AREA D, ZONE 6

1 NOT USED.

DRAWING NOTES

2 24"x4" DUCT DOWN TO DISHWASHER.

PROVIDE WIRE MESH OVER RETURN AIR

OPENING OF ALL FAN COIL UNITS.

GENERAL NOTES

No. Description Date

1 CPR 023R1 02/25/11

2 CPR 068 07/08/2011

3 CPR 230 02/23/2012

3 12"x10" EXHAUST AIR UP TO ROOF.2

File details come from the government source that posted it. Updated .