Addendum 1 Mechanical Drawings.pdf
PDF 3 MB Posted
- Solicitation number
- 36C77622B0063
About this file
This federal contract solicitation is for the expansion of Building 1 for primary care at the Fargo VA Medical Center. Key details include expanding part of the road between the medical center and flood wall, relocating the flood wall basin and road further away to comply with setback requirements, and ensuring the flood wall remains operational year-round. Foundation work will include helical piers to a suitable depth. The addition will provide a 2-story expansion with a whole health clinic on the first floor and mechanical space and offices for EMS in the basement. The solicitation was issued by the Department of Veterans Affairs Technology Acquisition Center located in Austin. The contract type and additional requirements are not specified in the provided document.
View the file
Other files
Show all 40
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
TT
TTTT
T
T
T
T
T
T
T
T
T
T
T T T T
T
T
T
F F F
T
F
FFFF
SD
SD
S D
S D
S D
SD SD
SD
S D
SD
S P
S P
S P
S P
SPSP SPSP
S P
S P
S P
SPSP SPSPSPSPSP
S P
S P
S P
S P
S P
S P
SP
S P
SP SPSP SP
S P
S P
S P
S P eA eA.1 eB eC eC.1 eD eE eF eG eH eI eI.1 eJ eK eL eM eN eO eP eQ e12
A
B
C D
BD - 114
GEMS
STORAGE/HOUSEKEEPING
EXPENDABLE
BD - 120
HOUSEKEEPING
EXPENDABLES
BD - 121
LEADS WORKROOM
BD - 122 STAFF LOUNGE
BD - 123
OFFICE SUPERVISORS
BD - 124
OFFICE GEMS
COORDINATOR
BD - 125
EQUIPMENT STORAGE
BD - 116
CART STORAGE
BD - 115
EMS WORKROOM
BD - 112
STANDALONE
PRIMARY
BD - 110
MECHANICAL
BD - 117
SECRETARY OFFICE
BD - 126
OFFICE EMS CHIEF
BD - 127
OFFICE EMS ASST
CHIEF
BD - 128
OFFICE ADMIN
OFFICER
BD - 129
CONFERENCE ROOM
BD - 130
BD - 131
ELECTRICAL
BD - 130A
WET ROOM
BD - 111
BD - 132
BD - 113
MEN'S LOCKER ROOM
BD - 118
W O
M E
N 'S
L O
C K
E R
R O
O M
B D
M 3.00
M 3.00
M 3.00
M 3.00
M 3.00
M 3.20
TU-9 TU-10 TU-11
TU-12
TU-13
TU-14
TU-15
TU-8
TU-7
TU-6
TU-1
TU-3
TU-2
TU-20
TU-19
TU-18TU-17
TU-16
TU-24
TU-21
TU-22
M-AHU-085
14"x10"
12"x10"
20"x10" RA22"x10"
14"x10"
"x
S A
"x
"x
30"x10" RA
30"x10" RA
16"x10"
18"x10" RA
16"x10" 10"x10"
6"x8"
"x
84"x14" EA
"x
S A
42"x26"
10"x8"
6"x8" SA 10"x10"
10"x8"
12"x10"
12"x10"
10"x10" 8"x10"
"x
R
A
"x
66"x16" RA 66"x14"
84"x14" O/A
18"x10"
TU-5 TU-4
"ø
6"ø
6"ø
4"ø
8"x8" S/A
6"ø
5"ø
8"x8" S/A 6"ø
"ø
8"x8"
UP TO ROOF34"x66" O/A30"x82" EA
UP TO 2ND FLOOR CHASE
30"x82" EA
"x
E A
4"ø
"x
S /A8"ø
6" ø
4"ø
"x
6"ø 6"ø
4"ø
"x
"x
S /A
"ø
8"ø
"ø
"x
"x
"x
"x
S /A
"x
S /A
8"ø
"x
6"ø
8"x10"
"ø
"x
"ø
"ø
"x
S /A
6"ø 8"ø
"x
S /A
"ø
"x
"ø
6"ø
6"x6" EA
L-3
L-1
L-5
EF-B08
10"x10" 6"ø
5"ø
5"ø
"x
6"ø8"ø
6"ø
S-5
115 CFM
E-1
50 CFM
S-7
50 CFM
S-7
50 CFM
E-2
115 CFM
E-2
75 CFM
S-5
75 CFM
S-7
50 CFM
S-7
50 CFM
E-1
50 CFM
E-1
50 CFM
6"x6" EA6"x6"
6"x6"
"x
6"x6"
E-1
50 CFM
10"x10"
S-1
100 CFM
S-1
100 CFM
S-2
175 CFM
R-1
100 CFM R-1
100 CFM
R-1
175 CFM
S-2
125 CFM
S-2
125 CFM
4"ø
6"ø
5"ø 5"ø
6"x6" 6"x6" 6"x6"
R-1
250 CFM S-2
150 CFM
S-2
150 CFM
R-1
300 CFM
R-1
200 CFM
S-2
200 CFM
S-1
100 CFM
S-1
80 CFM
R-1
80 CFMR-1
80 CFM
S-1
80 CFM
8"x8"
10"x8"
"ø
6"ø
5"ø
4"ø
"x
"x
4"ø
"x
"x
6"ø6"ø
S-3
300 CFM
ø10"
S-4
85 CFM
R-1
330 CFM
S-4
80 CFM
R-1
200 CFM
S-4
85 CFM S-4
80 CFM
S-5
140 CFM
S-5
140 CFM
R-1
280 CFM
S-1
100 CFM
S-1
100 CFM
R-1
200 CFM
R-1
165 CFM
R-2
500 CFM
S-1
80 CFM
S-1
85 CFM
6"ø
"ø
"ø
6"ø
26"x10"
5"ø ø8"
U P
D N
UP
D N
DN
40x14 RA
UP TO 1ST
FLOOR
D N
DN
UPUP
U P
8"x8" S/A 5"ø
6"ø6"ø
S-1
100 CFM
S-1
100 CFM
U P
40x14 SA UP
TO 1ST FLR.
6x6 EA UP
UP
10"x8"
UP
"x
"x
14"x8"
R-1
150 CFM
S-2
150 CFM
S-2
150 CFM
R-1
150 CFM
R-1
150 CFM
S-2
150 CFM
S-2
150 CFM
R-1
150 CFM
4"ø4"ø 4"ø
6"x6"
6"x6"
6"x6"
S-2
120 CFM
4"ø
S-2
120 CFM E-1
50 CFM
S-7
80 CFM R-4
80 CFM
R-1
240 CFM
S-7
50 CFM
D N
S-1
80 CFM
R-1
80 CFM
8"ø ø8"
R-1
300 CFM
S-1
100 CFM
S-2
150 CFM
S-2
150 CFM
6"x6"6"x6"
6"x6"
8"x8"
8"x8"
"x
E A
UH-1
D N
10"x10"
STAIRWELL
24-1
72"x38"
8"ø
42"x26"
FIRE DAMPERFIRE DAMPER
F D
SUMMIT FIRE CONSULTING
575 MINNEHAHA AVE WEST
ST. PAUL, MINNESOTA 55103
(612) 387-7050
CALIBRE
9090 S RIDGELINE BLVD, SUITE 105
HIGHLANDS RANCH COLORADO 80129
PHONE (303) 730-0434
ALBERTSON ENGINEERING, INC.
315 NORTH MAIN AVENUE, SUITE 200
SIOUX FALLS, SOUTH DAKOTA 57104
PH: (605) 274-0880
FOURFRONT DESIGN, INC.
517 7TH STREET
RAPID CITY, SOUTH DAKOTA 57701
PH: (605) 342-9470
FAX: (605) 342-2377
WWW.FOURFRONTDESIGN.COM
FOURFRONT
D E S I G N I N C.
Office of Construction and Facilities Management
Project Number
Building Number
Drawing Number
Dwg.
DrawnCheckedDate
Location
Project TitleDrawing Title
Approved: Project Director
ARCHITECTCONSULTANTS:
DateRevisions:
VA FORM 08-6231
o n e e ig h th in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e in c h o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t th re e in c h e s o n e fo o t
F
E
D
C
B
A
1 2 3 4 5 6 7 8 9
F
E
D
C
B
A
1 2 3 4 5 6 7 8 9 of 1/4/23#1 Addendum #1
# Revision Number Associated with Clouded Area
/6
/2
:4
:3
P
M
CONSTRUCTION DOCUMENTS
11 / 16 / 2021
Basement HVAC Plan
M 2.00
EXPAND BLDG. 1 FOR
PRIMARY CARE
JBMK
2101 ELM STREET
FARGO, ND 58102FARGO VAHCS
437-315
106 128
1/8" = 1'-0"
BASEMENT HVAC PLAN
30/40 UP TO
ROOF W/FD
T
T
T
T T T
T
TTTTTT
T
T
T
T T T T T
T
T
T
T
T
T
T
F
F F
F
F
F
F
T
TTTT T T T T
S D
SD
S D
SD
S D
SD
S D
S D
SD SD
S P
S P
S P
SP SP
S P
S P
S P
SPSP
S P
S P
S P
SP SPSP SP
SP SP
SPSP
S P
S P
S P
S P
SP SP
SP SP
TTTT T T T T T
T T
T
F
F
F
F
F
F
F
S P eA eA.1 eB eC eC.1 eD eE eF eG eH eI eI.1 eJ eK eL eM eN eO eP eQ e11 e12
A
B
C D
EXAM
1D -175
1D -176
EXAM
1D -174
EXAM
1D -172
EXAM
1D -171
CORRIDOR
CO05
RECEPTION/WAITING
1D -193
CORRIDOR
CO06
OFFICE
1D -199
WELLNESS
1D -191
EQUIP STG
1D -191A
OFFICE
1D -196
OFFICE
1D -197
LOGISTICS STG
1D -1941D -192
WORK ROOM
1D -173
C O
R R
ID
O
R
C O
EXAM
1D -177
EXAM
1D -179
EXAM
1D -181
EXAM
1D -184
EXAM
1D -185
EXAM
1D -186
EXAM
1D -187
EXAM
1D -189
EXAM
1D -190
ELECT
1D -195
BREAK ROOM
1D -188
STAFF TLT
1D -188A 1D -178
CLEAN LINEN
1D -180
1D -182
1D -183
STAIRWELL
24-2
OFFICE
1D -198
CONSULT PHARM
E1D -116
OFFICE (M.H.)
E1D -112
CONSULT (M.H.)
E1D -110
STAIRWELL
EBD - 70A
OFFICE (M.H.)
E1D -108
CORRIDOR
1D -121
WORK ROOM (P.C.
DOC'S
E1D -120
STAFF BREAK ROOM
E1D - 130
CONF
E1D - 129
LOCKER
E1D - 128
OFFICE (PHARM)
E1D -122
WORK ROOM (P.C.
DOC'S)
E1D -124
CONSULT (S.W.)
E1D -126
TOILET
E1D-127A
SOCIAL WORKERS
E1D -133
SOCIAL WORKER'S
CONSULT
E1D -132
TOILET
E1D -127
EXAM
E1D -104
M 3.00
M 3.00
M 3.00
M 3.00
TU-36 TU-37 TU-38 T
U
-3
TU-41 T
U
-4
T U
-4
TU-44
TU-40
TU-46
TU-45
T U
-4
T U
-5
T U
-5
T U
-5
TU-47TU-25TU-26TU-28TU-29TU-30
TU-31
TU-35
TU-33
TU-34
TU-32
TU-27
6"x8"
10"x8"
12"x10" 16"x10" RA
10"x10"
18"x10"
14"x24"
24"x10" RA18"x10" RA
"x
"x
"x
"x
R A
8"x10" 8"x8" RA 10"x10"
10"x10" 12"x10"
16"x10" RA
14"x10" 16"x10"
"x
R A
"x
S A
"x
"x
S A
18"x10"
36"x10" RA
6"x8"
14"x10"
"x
S A
8"x8" 8"ø
16"x10" SA
8"x8"
8"x10"
12"x10" SA
36"x10" RA 6"ø
30"x82" EA
TU-48
8"ø S-2
125 CFM
S-2
125 CFM
"ø
8"ø
S-3
250 CFM
R-1
250 CFM
12"x10" S/A
"x
6"ø S-1
100 CFM
R-1
100 CFM
4"ø 6"x6"
S-1
100 CFM
R-1
100 CFM
4"ø 6"x6"
"x
6"ø S-1
100 CFM
"x
6"ø
R-1
100 CFM
4"ø 6"x6"
R-1
100 CFM
"x
"4"ø
"x
6"ø S-1
100 CFM
UP
S-1
105 CFM
S-1
50 CFM
6"ø
"x
"ø
"x
6"ø
R-1
105 CFM
S-1
55 CFM
4"ø 4"ø
6"x6"
R-2
705 CFM
14"x10"
8"x6"
R-1
150 CFM
S-1
100 CFM
S-2
150 CFM
6"ø
6"ø
8"ø
4"ø4"ø
8"x6"
S-2
150 CFM
R-1
150 CFM
"x
"x
8"ø
"x ø8"
S-2
150 CFM
R-1
150 CFM
R-1
105 CFM
8"x6"6"x6"
S-2
105 CFM
"ø
4"ø4"ø
R-1
80 CFMR-1
100 CFM
6"x6"6"x6"
S-4
80 CFM
S-1
100 CFM
S-1
100 CFM
R-1
100 CFM
6"ø
6"ø
"x
4"ø
6"x6"
24"x8"
40x14 RA DN
40x14 SA
DN. TO
BSMT.
S-2
215 CFM
8"x8" S/A 8"ø
5"ø
R-1
215 CFM
8"x8" 4"ø
S-1
50 CFM
6"ø
"ø
S-1
50 CFMR-1
50 CFM
R-1
215 CFM
8"x8"
E-3
50 CFM
E-2
50 CFM
S-1
50 CFM
S-2
215 CFM
8"x8" S/A 8"ø
R-1
215 CFM
8"x8" S-2
215 CFM
8"x8" S/A 8"ø
5"ø
4"ø 8"x8"
S-1
50 CFM
E-1
50 CFM
6"x8"
8"x8"
8"x8" EA
R-1
305 CFM
"x
S /A
"x
6"ø 6"ø
6"ø S-1
100 CFM
S-1
100 CFM
S-1
105 CFM
E-1
50 CFM
S-7
50 CFM
"x
6"ø
6"ø S-1
60 CFM
S-1
60 CFM
6"ø
5"ø
5"ø 6"ø
8"x8"
6"x4" "x
6"x6" EA
D N
6"x6"
R-1
120 CFM
U P
UP DN
10"x10"
D N
UP
10"ø
EA DN
EF-120
L-6
S-3
250 CFM
R-1
250 CFM
S-2
125 CFM
S-2
125 CFM
10"ø
"x
S /A
8"ø 8"ø
8"x8" 5"ø
S-2
190 CFM
"x
R-1
190 CFM
8"x8"
S-2
190 CFM
"x
5"ø
R-1
190 CFM
8"x8" 5"ø
R-1
190 CFM
8"x8"
S-2
190 CFM
"x
5"ø
"x
R-1
190 CFM
S-2
190 CFM
8"x8"
"x
S-2
190 CFM
R-1
190 CFM
8"x8"
5"ø
R-1
150 CFM
R-1
370 CFM
10"x10"
4"ø
S-1
75 CFM
S-1
75 CFM
6"ø
6"ø 8 "x
"ø ø8" ø8" ø8" ø8" ø8"
UP
D N
10"x12" S/A
14"x12"
R-1
365 CFM
D N
DN
DN
D N
12"x10"
18"x10" 14"x10"
8"ø
8"ø 8"ø
8"ø
8"ø
8"ø
8"ø
D N
DN
D N
S-8
105 CFM
S-8
105 CFM
S -8
C
F M
S -8
C
F M
S -8
C
F M
S-8
105 CFM
S-8
105 CFM
"x
"x
8"x8"
"ø
M 2.01
L-1
40"x30" O/A
FROM BASEMENT
UP TO ROOF
eA eA.1 eB eC eC.1 eD eE eF eG eH eI eI.1 eJ eK eL eM eN eO eP eQ e11 e12
B C D
1 1 eC.1 eD eE eF
M 3.00
16"x10" SA 24"x8" RA 18"x10" RA
"x
S A
"x
14"x24" SA
36"x10" RA
10"x8"
6"ø SA
6"x6" EA
6"x6"
"x
R A
24"x10" RA
"x
14"x10"
6"x6"
"x
S /A
6"ø S/A
TU-27
36"x10" RA
40"x14" RA
40"x14" SA DOWN
DOWN
4"ø 4"ø
6"x6"
R-1
305 CFM
E-1
50 CFM
S-7
50 CFM
R-2
705 CFM
24"x8" RA
BELOW
6"x6"
ABOVE
6"x6" EA DOWN
18"x10"
UP
D N
SUMMIT FIRE CONSULTING
575 MINNEHAHA AVE WEST
ST. PAUL, MINNESOTA 55103
(612) 387-7050
CALIBRE
9090 S RIDGELINE BLVD, SUITE 105
HIGHLANDS RANCH COLORADO 80129
PHONE (303) 730-0434
ALBERTSON ENGINEERING, INC.
315 NORTH MAIN AVENUE, SUITE 200
SIOUX FALLS, SOUTH DAKOTA 57104
PH: (605) 274-0880
FOURFRONT DESIGN, INC.
517 7TH STREET
RAPID CITY, SOUTH DAKOTA 57701
PH: (605) 342-9470
FAX: (605) 342-2377
WWW.FOURFRONTDESIGN.COM
FOURFRONT
D E S I G N I N C.
Office of Construction and Facilities Management
Project Number
Building Number
Drawing Number
Dwg.
DrawnCheckedDate
Location
Project TitleDrawing Title
Approved: Project Director
ARCHITECTCONSULTANTS:
DateRevisions:
VA FORM 08-6231
o n e e ig h th in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e in c h o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t th re e in c h e s o n e fo o t
F
E
D
C
B
A
1 2 3 4 5 6 7 8 9
F
E
D
C
B
A
1 2 3 4 5 6 7 8 9 of 1/4/23#1 Addendum #1
# Revision Number Associated with Clouded Area
/6
/2
:4
:4
P
M
CONSTRUCTION DOCUMENTS
11 / 16 / 2021
First Floor HVAC Plan
M 2.01
EXPAND BLDG. 1 FOR
PRIMARY CARE
JBMK
2101 ELM STREET
FARGO, ND 58102FARGO VAHCS
437-315
107 128
1/8" = 1'-0"
FIRST FLOOR HVAC PLAN
SPECIFIC NOTES
1. RELOCATE EXISTING CEILING DIFFUSERS AND DUCTS AS SHOWN.
RECONNECT TO EXISTING TU'S (VAV'S).
2. CAP OPEN DUCTS.
3. LOCATE MECHANICAL CHASE FIRE DAMPERS ABOVE ACT IN AN
ACCESSIBLE / MAINTAINABLE LOCATION.
1/8" = 1'-0"
FIRST FLOOR MECHANICAL DEMOLITION PLAN
DEMOLITION NOTES
1. CAREFULLY REMOVE EXISTING DIFFUSERS AND DUCTS AS
SHOWN FOR RE-INSTALLATION IN NEW CEILINGS. SEE REMODEL
PLAN ABOVE AND ARCHITECTURAL PLANS.
2. REMOVE EXISTING FIN-TUBE RADIATORS IN PATH OF NEW WALLS
AND CORRIDOR. DEMOLISH PIPING BACK TO MAINS IN CEILING
AND CAP AT MAINS. SEE ARCHITECTURAL PLANS FOR LIMITS OF
REMODEL IN EXISTING BUILDING. SEAL HOLES AND PATCH
FINISHES.
3. REROUTE PIPING IN DEMOLISHED WALL AS NEEDED AND
RECONNECT TO EXISTING FIN-TUBE RADIATOR.
1/4" = 1'-0"
ENLARGED HVAC PLAN AT CHASE
eA eA.1 eB eC eC.1 eD eE eF eG eH eI eI.1 eJ eK eL eM eN eO eP eQ e12
A
B
C D
M 3.00
M 3.00
M 3.00
M 3.00
GOOSENECK DUCT
10' RADIUS CLEARANCE ZONE
L-4
SUMMIT FIRE CONSULTING
575 MINNEHAHA AVE WEST
ST. PAUL, MINNESOTA 55103
(612) 387-7050
CALIBRE
9090 S RIDGELINE BLVD, SUITE 105
HIGHLANDS RANCH COLORADO 80129
PHONE (303) 730-0434
ALBERTSON ENGINEERING, INC.
315 NORTH MAIN AVENUE, SUITE 200
SIOUX FALLS, SOUTH DAKOTA 57104
PH: (605) 274-0880
FOURFRONT DESIGN, INC.
517 7TH STREET
RAPID CITY, SOUTH DAKOTA 57701
PH: (605) 342-9470
FAX: (605) 342-2377
WWW.FOURFRONTDESIGN.COM
FOURFRONT
D E S I G N I N C.
Office of Construction and Facilities Management
Project Number
Building Number
Drawing Number
Dwg.
DrawnCheckedDate
Location
Project TitleDrawing Title
Approved: Project Director
ARCHITECTCONSULTANTS:
DateRevisions:
VA FORM 08-6231
o n e e ig h th in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e in c h o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t th re e in c h e s o n e fo o t
F
E
D
C
B
A
1 2 3 4 5 6 7 8 9
F
E
D
C
B
A
1 2 3 4 5 6 7 8 9 of 1/4/23#1 Addendum #1
# Revision Number Associated with Clouded Area
/6
/2
:4
:5
P
M
CONSTRUCTION DOCUMENTS
11 / 16 / 2021
Mechanical Roof Plan
M 2.10
EXPAND BLDG. 1 FOR
PRIMARY CARE
JBMK
2101 ELM STREET
FARGO, ND 58102FARGO VAHCS
437-315
108 128
1/8" = 1'-0"
MECHANICAL ROOF PLAN
SPECIFIC NOTES
1. INSTALL GOOSENECK ON 12" CURB. EXTEND CURB TO
EXISTING WALL AND PROVIDE ROOF-TO-WALL FLASHING.
SRR DETAIL 1/M5.01
2. PROVIDE BIRD AND INSECT SCREEN.
3. STEAM VENT.
4. INSTALL PENTHOUSE LOUVER ON 18" CURB WITH BIRD
AND INSECT SCREEN.
TU-24
TU-20
42"x26" SA
10"x8" SA
12"x10"
16"x10"
8"x10"
10"x10"
14"x10" SA
6"x8"
6"x8"
6"x6"
6"x6"
18"x10" RA
14"x10" RA
8"x8"
6"x6"
6"x6"
10"x8"
10"x8" RA
M-AHU-085
84"x14" O/A
16"x10" SA
40"x12" S A
30"x10" RA
6"x6"
6"x6"
6"x6"
8"x8"
"x
6"x6"
10"x22"
6"x6"
12"x10" RA
"x
6"x6"
22"x10"
8"x8"
22"x10"
"x
12"x12"
6"x6" E A
"x
E A
34"x66" O/A
"x
TU-9
22"x10" S A
10"x10" SA
TU-21TU-22
TU-19
TU-18
TU-17
TU-16
TU-15
TU-14
TU-13
TU-12
TU-11
TU-10
TU-8
TU-7 TU-6
TU-5
TU-4
TU-3
TU-2
TU-1
20"x20"
8"x8"
"x
6"x6"
"x
6"x6"
"x
6"x6"
"x
22"x10"
22"x10"
22"x10"
"x
10"x8" 2 "x
"x
66"x14"
66"x36"
66"x16" RA
10"x22"
6"x6"
10"x10"
18"x10"
20"x10" RA
12"x10"
22"x10"
"x
22"x20" 6"x6"
8"x8"
22"x22"
14"x8"
"x
"x
8"x8"
30"x10" RA
66"x16" RA
22"x12" R A
"x
72"x38"
22"x10" 84"x14" EA
L-3
S-2
S-1
S-1
S-7
S-7
S-5
S-7
S-7
S-5
S-3
S-2
S-2 S-2
S-2 S-2
S-1
S-2
S-2
S-2
S-2
S-2
S-1
S-2
S-2
S-7
S-1
S-1
S-1
S-1
S-1
S-1
S-5
S-5
S-1
S-1
S-1
84"x14" O /A
8"x8"8"ø
8"ø
8"x8"
R-16"ø
8"ø
S-2
10"x8"
8"ø
8"ø
R-1
R-1
R-4
R-1 R-1
R-1
R-1 S-7
8"ø
8"x8"
6"ø
8"x8"
6"ø
6"ø
E-1 6"x6" E
A
8"ø
8"x8"
8"ø 8"x8"
10"x10"
10"ø
8"x8"8"ø
6"ø
6"ø
8"x8" 6"ø
6"ø
8"ø
8"x8"
6"ø
8"x8"
8"ø
6"ø
R-1
R-1
R-1
R-1
R-1
R-1 R-1
R-1
8"x10" 8"ø
8"ø
10"x8"
8"ø
6"ø
8"x8"
6"ø
6"ø
26"x10" S A
20"x10" S A
10"x8"
S-4
S-4
S-4
6"ø
6"ø
S-4
6"ø 6"ø
6"ø
8"x8" 8"ø
8"ø
5"ø
6"ø 8"x8"
8"x8"
6"ø
8"x8"
6"ø
6"ø
R-1
R-1
R-1
R-1
R-1
R-2 8"x10"
8"ø
8"x8"
6"ø 6"ø
6"x6" EA
6"x6" EA
6"x6"
6"x6" 6"x6"
6"x6"
E-1
E-2 E-1
E-1
E-1
E-2
5"ø
5"ø
4"ø
5"ø
4"ø
4"ø
5"ø
5"ø
6"ø
4"ø
4"ø
4"ø
4"ø
6"ø
4"ø
4"ø
4"ø
5"ø
4"ø
5"ø
6"ø
6"ø
EF-B08
10"x10"
L-5
34"x66"
L-1
30"x120"
8"x6"
UP TO GOOSENECK
ON ROOF
TRANSITION TO
EXISTING OUTSIDE
AIR DUCTS
TRANSITION TO EXISTING
EXHAUST DUCTS
UP TO NEW FIRST
FLOOR HORIZ.
EXHAUST DUCT
TRANSITION TO EXISTING
EXHAUST DUCTS
40x14 SA UP TO
FIRST FLOOR
EA UP TO
FIRST
FLOOR
40x14 RA UP TO
FIRST FLOOR
30"x82" EA
"x
FIRE DAMPER
FIRE DAMPER
FIRE DAMPER
42"x14" SA
BELOW
BELOW
TU-50
6"x8"6"x8"
4"ø
4"ø
12"x10" RA
8"x8"
4"ø
4"ø
10"x10"
12"x10" SA
18"x10"
16"x10"
6"x8"
8"x8"
8"x8"
5"ø
4"ø
5"ø
5"ø
8"x10"
10"x10" SA
12"x10" 14"x10" SA
22"x10" S A
8"x10"
10"x10"
16"x10" SA 6"x4"
10"x10"
14"x10" 18"x10" RA
10"x10" RA
14"x10" RA
16"x10" RA
18"x10" 28"x10" R
A
18"x10"
24"x10" S A
36"x10" RA
TU-51
8"x6"
TU-52
8"x10"
8"x6"
"x
8"x6"
30"x82" EA
"x
E A
"x
O /A
"x
6"x6"
"x
8"x8"
"x
"x
8"x8"
"x
8"x8"
"x
8"x8"
8"x8"
"x
" 14"x10"
10"x22"
"x
8"x8" 8"x8"
"x
10"x10"
"x
5"ø
10"x10"
8"x8"
10"x8" SA
6"x6"
"x
6"x6"
"x
"x
4"ø 4 "ø
6"x6"
"x
4"ø
"x
8"x8"
24"x10" RA
36"x10"
"x
"x
8"x8"
4"ø
"x
8"x8"
8"x8"
"x
8"x8"
8"ø 4"ø
6"x6"
"x
6"x6"
"x
6"ø
6"x6"
6"x6"
"x
6"x6"
"x
TU-49
TU-47
TU-46
TU-45
TU-44
TU-43
TU-42
TU-41
TU-40
TU-39
TU-38
TU-37
TU-36
TU-35
TU-34
TU-33
TU-32
TU-31
TU-30
TU-29
TU-28
TU-27
TU-26
TU-25
6"x6" 14"x10"
16"x10" RA
12"x10"
22"x10"
10"x10"
14"x24" SA
"x
10"x8"
14"x10"
S-2
S-2
S-2
S-2
S-1
S-1
S-1
S-1
S-1
S-1
S-1
S-1
S-1
S-1
S-2
S-2
S-3
S-2
S-2
S-2
S-1
S-1
S-1
S-2
S-2
S-3
S-2
S-2
S-2
S-2
S-2
S-1
S-1
S-1
S-1
S-1
S-1 S-1
8"x10"
6"ø
8"ø
8"x10"
8"ø
8"x8"
8"ø
8"x8"
8"ø
S-4
6"ø 8"x8"
8"x8"
6"ø
6"ø
TU-48
8"x8"
6"ø
6"ø
8"x8"
6"ø
8"x8"
6"ø
6"ø
8"ø
8"x8"
8"x8"
8"ø
8"x8"
8"ø
8"x8"
8"ø
8"x8"
8"ø
12"x10"
8"ø8"ø
10"ø
8"x8"
8"ø
8"x8" 6"ø
6"ø
6"x6"
8"x8"
6"ø
6"ø
8"x8"
8"x8" EA
8"x8"
8"ø
8"ø
8"x8"
12"x10"
8"ø
8"ø
8"x8" 6"ø
8"x8" 6"ø
8"x8" 6"ø
8"x8" 6"ø
10"x8"
8"x8" 6"ø
10"x8"
6"ø
6"ø
8"x8"
6"ø
6"ø S-7
6"ø
10"x12" S/A
14"x12"
R-1
R-1
"x
R-1
R-1
R-1
R-1
R-1 R-1
R-1
R-1
R-1
R-1
R-1
R-1
R-1
R-1
R-1
R-1
R-1
R-1
R-1
R-1
R-1
R-1
R-1
R-1
R-2
R-1
R-1
E-1
E-2
E-3
E-1
6"x6" EA
24"x8" RA
24"x8"
24"x8"
10"ø
4"ø
5"ø
5"ø
5"ø
5"ø
8"ø 5"ø
4"ø
8"ø
4"ø
4"ø
4"ø
4"ø
4"ø
6"ø
6"ø
6"x6"
6"x8" E A
8"x8"
6"x6"
6"x6"
EF-120
L-6
30"x120"
6"x6"
T O
B A
S E
M E
N T
GOOSENECK
ON ROOF
T O
B A
S E
M E
N T
FIRE
DAMPER,
TYP.
S-8
S-8
S-8
S-8
8"ø
8"ø
8"ø
8"ø
S-8
S-8
8"ø
8"ø
S-8
8"ø
10"ø
SUMMIT FIRE CONSULTING
575 MINNEHAHA AVE WEST
ST. PAUL, MINNESOTA 55103
(612) 387-7050
CALIBRE
9090 S RIDGELINE BLVD, SUITE 105
HIGHLANDS RANCH COLORADO 80129
PHONE (303) 730-0434
ALBERTSON ENGINEERING, INC.
315 NORTH MAIN AVENUE, SUITE 200
SIOUX FALLS, SOUTH DAKOTA 57104
PH: (605) 274-0880
FOURFRONT DESIGN, INC.
517 7TH STREET
RAPID CITY, SOUTH DAKOTA 57701
PH: (605) 342-9470
FAX: (605) 342-2377
WWW.FOURFRONTDESIGN.COM
FOURFRONT
D E S I G N I N C.
Office of Construction and Facilities Management
Project Number
Building Number
Drawing Number
Dwg.
DrawnCheckedDate
Location
Project TitleDrawing Title
Approved: Project Director
ARCHITECTCONSULTANTS:
DateRevisions:
VA FORM 08-6231
o n e e ig h th in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e in c h o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t th re e in c h e s o n e fo o t
F
E
D
C
B
A
1 2 3 4 5 6 7 8 9
F
E
D
C
B
A
1 2 3 4 5 6 7 8 9 of 1/4/23#1 Addendum #1
# Revision Number Associated with Clouded Area
/6
/2
:4
:5
P
M
CONSTRUCTION DOCUMENTS
11 / 16 / 2021
HVAC Isometric Views
M 3.10
EXPAND BLDG. 1 FOR
PRIMARY CARE
JBMK
2101 ELM STREET
FARGO, ND 58102FARGO VAHCS
437-315
110 128
BASEMENT DRYSIDE ISOMETRIC VIEW
FIRST FLOOR DRYSIDE ISOMETRIC VIEW
GENERAL NOTES
A. THIS DRAWING IS FOR REFERENCE AND SPACE ALLOCATION COORDINATION.
B. SEE SHEET M3.20 FOR ENLARGED MECHANICAL ROOM PLAN.
SPECIFIC NOTES
1. 40" X 14" SA DOWN TO BASEMENT.
2. 40" X 14" RA DOWN TO BASEMENT.
3. 6" X 6" EA DOWN TO BASEMENT.
FD
HEAT EXCHANGERS
EQUIP TAG MFGR MODEL
CIRCULATING FLUID MODULATING
CONTROL V
(LBS/HR)
STEAM
PRESSURE
DIAMETER/
LENGTH NOTES
FLUID GPM
TEMP IN
(°F)
TEMP
OUT (°F)
PRESSURE
DROP
BD117-HX-3 TACO G08406-S 50% PPG 40 150 180 0.74 619.6 15 8"/40" 1
BD117-HX-4 TACO G08406-S 50% PPG 40 150 180 0.74 619.6 15 8"/40" 1
NOTES: 1. MANUFACTURER IS FOR BASIS OF DESIGN ONLY. OTHER MANUFACTURERS ARE ALLOWED.
CIRCULATING PUMPS
BASIS OF DESIGN
SYSTEM
CIRCULATING FLUID
% EFF.
MOTOR
NOTES
EQUIP TAG MFGR TYPE MODEL FLUID GPM PUMP FT
HEAD
TEMP (°
F) NOM. HP VOLT/
PHASE
BD117-HWP-1 TACO
SELF SENSING
VERTICAL CLOSE
COUPLED
SKV1509A-A-4P-PD HEATING 50% PPG 35 40 180 53.6 3 208/3 1,2
BD117-HWP-2 TACO
SELF SENSING
VERTICAL CLOSE
COUPLED
SKV1509A-A-4P-PD HEATING 50% PPG 35 40 180 53.6 3 208/3 1,2
NOTES 1. MANFACTURER IS BASIS OF DESIGN, OTHER MANUFACTURERS WILL BE ALLOWED.
2. PROVIDE WITH DISCONNECT, INTEGRAL VFD, SUCTION DIFFUSER, AND TRIPLE DUTY VALVE.
Drawing Title
Approved: Project Director
Project Title
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
Dwg.Revisions: Date
CONSULTANTS: ARCHITECT/ENGINEERS: 437-315
11 / 16 / 2021
Office of Construction and Facilities Management
19.2481.A08 of
EXPAND BLDG. 1 FOR
PRIMARY CARE
CONSTRUCTION DOCUMENTS
FARGO VAHCS
2101 ELM STREET
FARGO, ND 58102
FOURFRONT DESIGN, INC.
517 7TH STREET
RAPID CITY, SOUTH DAKOTA
57701
PH: (605) 342-9470
FAX: (605) 342-2377
WWW.FOURFRONTDESIGN.COMFOUR FRON T
DESIGN IN C.
SUMMIT FIRE CONSULTING
575 MINNEHAHA AVE WEST
ST. PAUL, MINNESOTA 55103
(612) 387-7050
CALIBRE
9090 S RIDGELINE BLVD, SUITE 105
HIGHLANDS RANCH COLORADO 80129
PHONE (303) 730-0434
ALBERTSON ENGINEERING, INC.
315 NORTH MAIN AVENUE, SUITE 200
SIOUX FALLS, SOUTH DAKOTA 57104
PH: (605) 274-0880
#1 ADDENDUM #1 1/4/23
# Revision Number Associated with Clouded Area
Mechanical Schedules
M 4.00
JBMK 113
FIN TUBE RADIATORS
EQUIP
TAG MFGR FLUID GPM MBH
PPG
VELOCITY
(FT/SEC)
EWT (°F) LWT (°F) PRESSURE
DROP (FT) FINS/FOOT
ELEMENT
LENGTH
(FT)
ROWS
TUBE
DIAMETER
(IN)
HEIGHT ALUMINUM FINS NOTES
FT-01 MODINE 50% PPG 0.43 4.1 3 180 160 0.5 34 7 2 0.75 14 3.25"X2.75" 1
FT-02 MODINE 50% PPG 0.25 2.3 3 180 160 0.5 34 4 2 0.75 14 3.25"X2.75" 1
FT-03 MODINE 50% PPG 0.37 3.5 3 180 160 0.5 34 6 2 0.75 14 3.25"X2.75" 1
FT-04 MODINE 50% PPG 0.31 2.9 3 180 160 0.5 34 5 2 0.75 14 3.25"X2.75" 1
FT-05 MODINE 50% PPG 0.37 3.5 3 180 160 0.5 34 6 2 0.75 14 3.25"X2.75" 1
FT-08 MODINE 50% PPG 0.43 4.1 3 180 160 0.5 34 7 2 0.75 14 3.25"X2.75" 1
FT-09 MODINE 50% PPG 0.34 3.2 3 180 160 0.5 34 5 1/2 2 0.75 14 3.25"X2.75" 1
FT-10 MODINE 50% PPG 0.34 3.2 3 180 160 0.5 34 5 1/2 2 0.75 14 3.25"X2.75" 1
FT-11 MODINE 50% PPG 0.34 3.2 3 180 160 0.5 34 5 1/2 2 0.75 14 3.25"X2.75" 1
FT-12 MODINE 50% PPG 0.43 4.1 3 180 160 0.5 34 7 2 0.75 14 3.25"X2.75" 1
FT-13 MODINE 50% PPG 0.43 4.1 3 180 160 0.5 34 7 2 0.75 14 3.25"X2.75" 1
FT-14 MODINE 50% PPG 0.49 4.7 3 180 160 0.5 34 8 2 0.75 14 3.25"X2.75" 1
FT-15 MODINE 50% PPG 0.49 4.7 3 180 160 0.5 34 8 2 0.75 14 3.25"X2.75" 1
FT-16 MODINE 50% PPG 0.25 2.3 3 180 160 0.5 34 4 2 0.75 14 3.25"X2.75" 1
FT-17 MODINE 50% PPG 0.37 3.5 3 180 160 0.5 34 6 2 0.75 14 3.25"X2.75" 1
FT-18 MODINE 50% PPG 0.37 3.5 3 180 160 0.5 34 6 2 0.75 14 3.25"X2.75" 1
FT-19 MODINE 50% PPG 0.31 2.9 3 180 160 0.5 34 5 2 0.75 14 3.25"X2.75" 1
FT-20 MODINE 50% PPG 0.19 1.8 3 180 160 0.5 34 3 2 0.75 14 3.25"X2.75" 1
FT-24 MODINE 50% PPG 0.37 3.5 3 180 160 0.5 34 6 2 0.75 14 3.25"X2.75" 1
FT-25 MODINE 50% PPG 0.31 2.9 3 180 160 0.5 34 5 2 0.75 14 3.25"X2.75" 1
FT-26 MODINE 50% PPG 0.25 2.3 3 180 160 0.5 34 4 2 0.75 14 3.25"X2.75" 1
FT-27 MODINE 50% PPG 0.31 2.9 3 180 160 0.5 34 5 2 0.75 14 3.25"X2.75" 1
FT-28 MODINE 50% PPG 0.25 2.3 3 180 160 0.5 34 4 2 0.75 14 3.25"X2.75" 1
FT-29 MODINE 50% PPG 0.25 2.3 3 180 160 0.5 34 4 2 0.75 14 3.25"X2.75" 1
FT-30 MODINE 50% PPG 0.19 1.8 3 180 160 0.5 34 3 2 0.75 14 3.25"X2.75" 1
FT-31 MODINE 50% PPG 0.25 2.3 3 180 160 0.5 34 4 2 0.75 14 3.25"X2.75" 1
FT-32 MODINE 50% PPG 0.25 2.3 3 180 160 0.5 34 4 2 0.75 14 3.25"X2.75" 1
FT-33 MODINE 50% PPG 0.25 2.3 3 180 160 0.5 34 4 2 0.75 14 3.25"X2.75" 1
FT-34 MODINE 50% PPG 0.31 2.9 3 180 160 0.5 34 5 2 0.75 14 3.25"X2.75" 1
FT-35 MODINE 50% PPG 0.37 3.5 3 180 160 0.5 34 6 2 0.75 14 3.25"X2.75" 1
NOTES: 1. MANUFACTURER IS FOR BASIS OF DESIGN ONLY. OTHER MANUFACTURERS ARE ALLOWED.
UNIT HEATER
EQUIP TAG MFGR MODEL MBH GPM EWT LWT PPG% WPD CFM FAN KW
VOLTAGE
(V/PH/HZ) NOTES
UH-01 TRANE S-A18 16.6 1.92 180 160 50 2.23 500 16 110/1/60 1
NOTES: 1. MANUFACTURER IS BASIS OF DESIGN. OTHER MANUFACTURERS ARE ALLOWED.
GRILLES REGISTERS AND DIFFUSERS SCHEDULE
EQUIP
TAG MFGR MODEL
NUMBER BORDER PANEL
SIZE
NECK
SIZE
MAX
CFM THROW NC SP NOTES
S-1 KRUEGER 1400 LAY-IN 24/24 6" 110 9 - 0.037 1
S-2 KRUEGER 1400 LAY-IN 24/24 8" 220 12 11 0.029 1
S-3 KRUEGER 1400 LAY-IN 24/24 10" 350 15 17 0.070 1
S-4 KRUEGER 51400 SURFACE 24/24 6" 110 9 - 0.037 2,3
S-5 KRUEGER 51400 SURFACE 24/24 8" 220 12 11 0.029 2,3
S-6 KRUEGER 51400 SURFACE 24/24 10" 350 15 17 0.070 2,3
S-7 KRUEGER 5800 SURFACE 8/8 6/6 100 14 - 0.050 2,3,4
S-8 KRUEGER 5800 SURFACE 10/10 8/8 200 19 18 0.050 2,3,4
S-9 KRUEGER 1975 LINEAR SLOT 4/48 6" 125 17 24 0.050 2,6
R-1 KRUEGER EG10 LAY-IN 24/12 22/10 1000 - 20 0.050 2,3,4
R-2 KRUEGER EG10 LAY-IN 24/24 22/22 2000 - 20 0.050 2,3,4
E-1 KRUEGER 580 SURFACE 12/8 10/6 100 - 18 0.035 2,3,5
E-2 KRUEGER 580 SURFACE 14/10 12/8 300 - 18 0.028 2,3,5
NOTES: 1. STEEL CONSTRUCTION. MANUFACTURER IS BASIS OF DESIGN, OTHER MANUFACTURERS ALLOWED.
2. ALUMINUM CONSTRUCTION. MANUFACTURER IS BASIS OF DESIGN, OTHER MANUFACTURERS ALLOWED.
3. PROVIDE OBD.
4. DOUBLE DEFLECTION 22.5 DEGREE DEFLECTION.
5. SINGLE DEFLECTION 35 DEGREE DEFLECTION.
6. PROVIDE STRAIGHT, 3/4" SLOT, 2 SLOT, BUTT CUT, END CAP AND BLADES.
RADIANT CEILING PANELS
EQUIP TAG MFGR TYPE
PPG
(%) GPM MBH EWT (F) LWT (F) ROWS
SIZE
(FT) NOTES
RP-1 STERLING MODULAR RADIANT CEILING PANEL 50 0.1 1.27 180 150 6 4/2 1,2,3
RP-2 STERLING MODULAR RADIANT CEILING PANEL 50 0.1 1.27 180 150 6 4/2 1,2,3
RP-3 STERLING MODULAR RADIANT CEILING PANEL 50 0.1 1.27 180 150 6 4/2 1,2,3
RP-4 STERLING MODULAR RADIANT CEILING PANEL 50 0.1 1.27 180 150 6 4/2 1,2,3
RP-5 STERLING MODULAR RADIANT CEILING PANEL 50 0.1 1.27 180 150 6 4/2 1,2,3
RP-6 STERLING MODULAR RADIANT CEILING PANEL 50 0.1 1.27 180 150 6 4/2 1,2,3
RP-7 STERLING MODULAR RADIANT CEILING PANEL 50 0.1 1.27 180 150 6 4/2 1,2,3
NOTES: 1. PROVIDESTANDARD FOIL FACE INSULATION.
2. UNITS DERATED FOR 50% PPG.
3. MANUFACTURER IS BASIS OF DESIGN ONLY, OTHER MANUFACTURERS ALLOWED.
LOUVERS SCHEDULE
EQUIP
TAG MFGR MODEL
NUMBER TYPE SERVICE CFM SP (IN) WIDTH
(IN)
HEIGHT
(IN)
DEPTH
(IN)
FREE
AREA
(SF)
NOTES
L-1 ARCHITECTURAL
LOUVERS E6DP EXTRUDED DRAINABLE BLADE,
COLOR BY ARCHITECH EXHAUST - - 36 288 6 34.5 2
L-2 NOT USED - - - - - - - - - -
L-3 GREENHECK EDJ-601 EXTRUDED DRAINABLE HEAD EXHAUST 9,080 0.23 84 26 36 7.5 2
L-4 GREENHECK ESD-635PD GRAVITY LOUVERED PENTHOUSE INTAKE 9,080 0.18 48 40 - 10.2 2
L-5 GREENHECK ESD-635 EXTRUDED DRAINABLE HEAD EXHAUST 390 0.08 36 12 6 0.5 1,2
L-6 GREENHECK ESD-202 EXTRUDED DRAINABLE HEAD EXHAUST 250 0.13 48 6 2 0.3 1,2
NOTES: 1. PROVIDE WITH MOTORIZED DAMPER.
2. MANUFACTURER IS BASIS OF DESIGN ONLY. OTHER MANUFACTURERS ALLOWED.
EXHAUST FAN SCHEDULE
EQUIP
TAG MFGR TYPE MODEL NUMBER
EXHAUST
(CFM) SP (IN) HP FAN
RPM
VOLTAGE
(V/PH,HZ)
SOUND
(SONES) L/W/H (IN) WEIGHT (LBS) NOTES
EF-B08 GREENHECK INLINE SQ-98-VG 390 1 1/3 1,817 115/1/60 13.7 21/15/15 56 1,2
EF-120 GREENHECK INLINE SQ-97 250 1.6 1/2 2,479 208/3/60 22 21/15/15 52 1,2
NOTES: 1. PROVIDE DISCONNECT.
2. MANUFACTURER IS BASIS OF DESIGN. OTHER MANUFACTURERS ALLOWED.
EXPANSION TANKS
EQUIP
TAG MFGR MODEL TYPE
TANK
VOLUME
(GAL)
TANK ACCEPT
(GAL)
HEIGHT
(IN)
DIAMETER
(IN)
WEIGHT
(LBS) NOTES
EXP-85 TACO CBX84-125 BLADDER 22 12 39 16 150 1
NOTES: 1. MANUFACTURER IS BASIS OF DESIGN. OTHER MANUFACTURERS ALLOWED.
AIR SEPARATOR SCHEDULE
EQUIP
TAG MFGR MODEL SYSTEM
CONNECTION SIZE
(IN)
FLOW
(GPM) HEIGHT (IN) DIAMETER
(IN) NOTES
AS-85 TACO 4902ADT-125 HOT WATER 2 73 17 10
NOTES: 1. MANUFACTURER IS BASIS OF DESIGN. OTHER MANUFACTURERS ALLOWED.
CONDENSATE PUMPS
BASIS OF DESIGN
SYSTEM
CIRCULATING FLUID MOTOR
NOTES
EQUIP TAG MFGR TYPE MODEL FLUID GPM PUMP FT
HEAD
TEMP
(° F)
NOM.
HP
VOLT/
PHASE
BD117-CP-1 SKIDMORE DUPLEX VCS-151 1/2 CONDENSATE WATER 22.5 34.5 180 1/2 208/3 1,2
NOTES 1. MANFACTURER IS BASIS OF DESIGN, OTHER MANUFACTURERS WILL BE ALLOWED.
2. PROVIDE 3551 NEMA 1 CONTROL PANEL AND 45 GALLON RECEIVER.
POT FEEDER SCHEDULE
EQUIP
TAG MFGR MODEL TYPE SYSTEM
TANK
VOLUME
(GAL)
HEIGHT
(IN)
DIAMETER
(IN) NOTES
PF-1 GTP DB2/QC-VPDB DOME BOTTOM FEEDER HOT WATER 2 27 6 1,2
NOTES: 1. PROVIDE WITH QUICK CONNECT WITH VALVE PACKAGE
2. BASIS OF DESIGN. OTHER MANUFACTURERS ALLOWED.
AutoCAD SHX Text one eighth inch = one foot
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text B
AutoCAD SHX Text A
AutoCAD SHX Text C
AutoCAD SHX Text D
AutoCAD SHX Text E
AutoCAD SHX Text F
AutoCAD SHX Text 6"
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 6"
AutoCAD SHX Text one and one half inches = one foot
AutoCAD SHX Text one inch = one foot
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 6"
AutoCAD SHX Text 6"
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text three quarters inch = one foot
AutoCAD SHX Text one half inch = one foot
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text three eighths inch = one foot
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text one quarter inch = one foot
AutoCAD SHX Text
VA FORM 08-6231
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text F
AutoCAD SHX Text E
AutoCAD SHX Text D
AutoCAD SHX Text C
AutoCAD SHX Text B
AutoCAD SHX Text A
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
DRAW THRU
BLOW THRU
2" [50mm]
PLUS X
1" [25mm]
MINIMUM
X
2X
UNIT TYPE A B
WHERE X = STATIC PRESSURE IN PAN
DRAIN LINE SHALL BE AT LEAST THE SAME
SIZE AS THE NIPPLE ON THE DRAIN PAN
PIPING SHALL BE RIGID COPPER TYPE L
UNLESS NOTE BELOW IS MET
PITCH DOWN
TOWARD DRAIN
CLEAN OUT
FLOOR SINK
DRAIN
PAN
NOTE:
1. DIELECTRIC FITTING TO BE USED WHEN TWO DISSIMILAR METALS
ARE TO BE CONNECTED.
A B
[2 5m m
DIELECTRIC
FITTING
1"
HWS
HWR
3-WAY MODULATING
CONTROL VALVE
REFER TO SCHEDULECOIL
1/4" MANUAL
AIR VENT
FLOW CONTROL VALVE
BALL VALVE (TYP.)
STRAINER1/2" DRAIN VALVE
UNION
COIL
TEST PLUG (TYP.)
REDUCER, IF REQUIRED
WATER RETURN
MANUAL AIR VENT
UNION CONNECTIONS
(TYP.)
WATER SUPPLY
SHUT OFF VALVE
MV
2-WAY MODULATING
CONTROL VALVE
SINGLE COIL
WATER COIL
AIR VENT WHEN
COIL IS NOT
SELF-VENTING
DRAIN WHEN COIL IS
NOT SELF-DRAINING
TEST PLUG (TYP.)
PIPE HANGER SHALL
SUPPORT PIPING
INDEPENDENT OF COIL
REDUCER,
IF REQUIRED
DRAIN
NOTES:
1. WHEN COIL IS INCLUDED IN CASING MOUNTED ON VIBRATION ISOLATORS THE
FIRST 2 HANGERS FOR EACH PIPE SHALL BE SPRING & NEOPRENE TYPE. TYPE "H"
FOR 100mm [4"]Ø PIPE & SMALLER. TYPE "H-P" FOR 125mm [5"]Ø PIPE & LARGER.
2. PIPING SHALL BE INSTALLED IN SUCH MANNER THAT IT WILL NOT BLOCK THE
SWING OR USE OF ACCESS DOORS OR PANELS; NEITHER SHALL IT BLOCK THE
SERVICING OF FILTERS, VALVES, OR EQUIPMENT.
FE
MV
MV
MV
MV
PRESSURE GAUGE
DIFFERENTIAL PRESSURE SENSOR
TEST PORT
BALL VALVE
VERTICAL
IN-LINE PUMP
FLEXIBLE PUMP CONNECTOR
SUCTION DIFFUSER
BALL VALVE
2" HOT
WATER
SNUBBER
END-OF-LINE TERMINAL UNIT PIPING
TERMINAL UNIT PIPING
HWS
HWRTT
TT
TEMPERATURE GAUGE
TEMPERATURE SENSOR
SINGLE COIL
WATER COIL
AIR VENT WHEN
COIL IS NOT
SELF-VENTING
DRAIN WHEN COIL IS
NOT SELF-DRAINING
TEST PLUG (TYP.)
PIPE HANGER SHALL
SUPPORT PIPING
INDEPENDENT OF COIL
REDUCER,
IF REQUIRED
DRAIN
NOTES:
1. WHEN COIL IS INCLUDED IN CASING MOUNTED ON VIBRATION ISOLATORS THE
FIRST 2 HANGERS FOR EACH PIPE SHALL BE SPRING & NEOPRENE TYPE. TYPE "H"
FOR 100mm [4"]Ø PIPE & SMALLER. TYPE "H-P" FOR 125mm [5"]Ø PIPE & LARGER.
2. PIPING SHALL BE INSTALLED IN SUCH MANNER THAT IT WILL NOT BLOCK THE
SWING OR USE OF ACCESS DOORS OR PANELS; NEITHER SHALL IT BLOCK THE
SERVICING OF FILTERS, VALVES, OR EQUIPMENT.
FE
MV
MV
MV
CWS
CWRTT
TT
3-WAY MODULATING
CONTROL VALVE
TEMPERATURE GAUGE
TEMPERATURE SENSOR
PRESSURE
GAUGE AND
SNUBBER DIFFERENTIAL
PRESSURE
SENSOR
FLOOR LEVEL
1/4" PLATE WELDED
STEEL SUPPORT
CONCRETE
INERTIA
BASE
ADJUSTABLE
SPRING
ISOLATORS
CONCRETE
PAD (4" MIN)
PT
PT
1/4 TURN BOILER
DRAIN VALVE WITH
BRASS CAP, TYP.
1/4 TURN BOILER DRAIN
VALVE WITH BRASS CAP, TYP.
1/4 TURN BOILER
DRAIN VALVE WITH
BRASS CAP, TYP.
3-WAY MODULATING
CONTROL VALVE
PRESSURE
GAUGE AND
SNUBBER DIFFERENTIAL
PRESSURE
SENSOR
PT
1/4 TURN BOILER DRAIN
VALVE WITH BRASS CAP, TYP.
TRIPLE DUTY VALVE
STRAINER WITH
BLOWDOWN VALVE
STRAINER WITH
BLOWDOWN VALVE
STRAINER WITH
BLOWDOWN VALVE
CHECK VALVE
H W
S
H W
R
STRAINER
BASE, SEE DETAIL 4/M 5.10
FLOW CONTROL VALVE FLOW CONTROL VALVE
Drawing Title
Approved: Project Director
Project Title
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
Dwg.Revisions: Date
CONSULTANTS: ARCHITECT/ENGINEERS: 437-315
11 / 16 / 2021
Office of Construction and Facilities Management
19.2481.A08 of
EXPAND BLDG. 1 FOR
PRIMARY CARE
CONSTRUCTION DOCUMENTS
FARGO VAHCS
2101 ELM STREET
FARGO, ND 58102
FOURFRONT DESIGN, INC.
517 7TH STREET
RAPID CITY, SOUTH DAKOTA
57701
PH: (605) 342-9470
FAX: (605) 342-2377
WWW.FOURFRONTDESIGN.COMFOUR FRON T
DESIGN IN C.
SUMMIT FIRE CONSULTING
575 MINNEHAHA AVE WEST
ST. PAUL, MINNESOTA 55103
(612) 387-7050
CALIBRE
9090 S RIDGELINE BLVD, SUITE 105
HIGHLANDS RANCH COLORADO 80129
PHONE (303) 730-0434
ALBERTSON ENGINEERING, INC.
315 NORTH MAIN AVENUE, SUITE 200
SIOUX FALLS, SOUTH DAKOTA 57104
PH: (605) 274-0880
#1 ADDENDUM #1 1/4/23
# Revision Number Associated with Clouded Area
Mechanical Details Building 1 - Wet Side 1
M 5.10
JBMK 117
SCALE:2
AHU HEATING
WATER COILS - PIPING CONNECTIONS
N.T.S. SCALE:3
AIR TERMINAL UNIT
REHEAT COIL - PIPING CONNECTIONS
N.T.S.SCALE:1
AHU CHILLED
WATER COILS - PIPING CONNECTIONS
N.T.S. SCALE:4 INERTIA BASE
N.T.S.
SCALE:5 VERTICAL IN-LINE PUMP DETAIL
N.T.S. SCALE:6 AIR HANDLING UNIT DRAIN TRAP DETAIL
N.T.S. SCALE:7 RADIANT CEILING PANEL CONNECTION DETAIL
N.T.S. SCALE:8 FIN TUBE CONNECTION DETAIL
N.T.S.
AutoCAD SHX Text one eighth inch = one foot
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text B
AutoCAD SHX Text A
AutoCAD SHX Text C
AutoCAD SHX Text D
AutoCAD SHX Text E
AutoCAD SHX Text F
AutoCAD SHX Text 6"
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 6"
AutoCAD SHX Text one and one half inches = one foot
AutoCAD SHX Text one inch = one foot
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 6"
AutoCAD SHX Text 6"
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text three quarters inch = one foot
AutoCAD SHX Text one half inch = one foot
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text three eighths inch = one foot
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text one quarter inch = one foot
AutoCAD SHX Text
VA FORM 08-6231
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text F
AutoCAD SHX Text E
AutoCAD SHX Text D
AutoCAD SHX Text C
AutoCAD SHX Text B
AutoCAD SHX Text A
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
HEATING ONLY PANELS
AutoCAD SHX Text
HWS
AutoCAD SHX Text
HWR
AutoCAD SHX Text RUNOUT & INTERCONNECTING PIPING. PROVIDE DIELECTRIC FITTINGS AS REQUIRED. CIRCUIT TO COMPLY WITH SPECIFIED CAPACITY & PRESSURE DROP. (TYP.)
AutoCAD SHX Text
HWS
AutoCAD SHX Text
HWR
FIN TUBE
FT-16
FT
-0
FT-02
FT-17
FT-03
FT-18
FT-04
TU-19
TU-20
TU-52
TU-18
TU-21
TU-22
TU-17
FT-19
FT-05
TU-51TU-50
FT-20
TU-16
FT-08
FT
-2
FT-09FT-10
FT-24FT-25
FT-11
FT-26
FT-12
FT-27
FT-13
FT-28FT-29FT-30
TU-2
TU-1
TU-3
TU-15
TU-14
TU-13TU-12TU-11TU-10TU-9
FT
-3
TU-24
TU-4TU-5
TU-7
TU-6
TU-8
FT
-3
FT
-1
FT
-3
FT
-1
FT
-3
FT
-3
U H
-0
TO MECH. ROOM
TO MECH. ROOM
2" PHWS
2" PHWR
1-1/4" RHWS
1-1/4" RHWR
TU-49TU-48
TU-46
TU-45
1-1/2" RHWS
1-1/2" RHWR
TU-47
TU-44
TU-40
TU-43
TU-42TU-41TU-39TU-38TU-37
TU-36
TU-35
TU-34
TU-32
TU-31
TU-33
TU-30 TU-29 TU-28
1-1/2" RHWR
1-1/2" RHWS
TO MECH ROOM
TU-27
TU-26 TU-25
1-1/2" 1-1/2"
1-1/2"
1-1/2" RHWS
1-1/2" RHWR1-1/2"
1-1/2" RHWR
1-1/2" RHWS
RA ([4]13X13)
F&T TRAP
F&T TRAP
TO STEAM
CONDENSATE
RETURN
F&T TRAP
TO LOW
PRESSURE
STEAM LINE
FA (70 X 38) EA (70X14)
C R
-L
CR-L
LPSLPS
CR-L
.0 p si g
7.
lb /h r
.6
G
PM
ET-2
11 GAL
HWP-1
35 GPM
HX-4
HX-3
3/ 4"
PT
F&T
TRAP
F&T TRAP
2/3
1/3
BYPASS
TT
TT
TO FD
TO STEAM
CONDENSATE
RETURN
TT
TT
V PT
TO FD
F&T
TRAP
TO LOW
PRESSURE
STEAM LINE
F&T TRAP
2/3
1/3
BYPASS
TO STEAM
CONDENSATE
RETURN
V PT
TO LOW
PRESSURE
STEAM LINE
CR-L
LPS
LPS
LPS
LPS
CR-L
2 1/2" HWS2 1/2" HWS
2 1/2" HWR
HWP-2
35 GPM
PT
SA (41X25)
AHU-85
9080 CFM
FD
MV
PT
FE
TT
TT
MV
MV
PT
FE
TT
TT
MV
2" HWR
2" HWS
2 1/2" CHWR
2 1/2" CHWS
.8
G
PM
(39.32 GPM)
2" PHWS
2" PHWR1-1/4" RHWS
1-1/4" RHWR
(E) 6" CHWR
(E) 6" CHWS
A B
A
B
C
2 1/2" HWR
C
TO
B
AS
EM
EN
T
TU
'S
(V
AV
'S
TO
F
IR
ST
F
LO
O R
T U
'S (V
AV
'S
TO
P
ER
IM
ET
ER
B
AS
EB
O
AR
D
FI
N
T U
BE
R
AD
IA
TO
R
S
RP-01
RP-02
RP-03
RP-04
RP-05
RP-06
RP-07
V
4XD2 MIN.
10XD1 MIN.
SIPHON
i.e. PIGTAIL
(TYP.)
4"Ø
PILOT CONTROL LINE
DRIP PAN ELBOW
6"Ø
PSV
VENT TO ATMOSPHERE
D1 D2
M5.11
SIM.
1-PRV1A
1-PRV1B
F&T
TRAP
F&T
TRAP
N.C. BYPASS
LPS
LPS
LPS
F&T
TRAP
CR-H
LPSHPS
HPS
H
PS
C R
-L
PC
PC
(E) 2" PC
1- 1/
4" P
C
FS
CR-L
RUN VENT TO CEILING
AND BACK DOWN TO FS.
4" V
3/4" PHWS
3/4" PHWR
3/4"
1"
3/4" PHWS
3/4" PHWR
1" PHWS
1" PHWR
1-1/4"
1-1/4" PHWS
1-1/4" PHWR
1-1/4"
1-1/2" PHWS
1-1/2" PHWR
1-1/2" PHWS
1-1/2" PHWR
1-1/2" 2"
2"
1"
2"
1"
3/4" RHWR
3/4" RHWS
3/4" RHWR
3/4" RHWS
1" RHWR
1" RHWS
1"
1-1/4" RHWR
1-1/4" RHWS
1" RHWR
1" RHWS
3/4" RHWR
3/4" RHWS
3/4" RHWR
3/4" RHWS
1-1/4" RHWR
1-1/4" RHWS
1-1/2" RHWR
1-1/2" RHWS
1-1/2"
3/4" RHWS BRANCH, TYP.
3/4" RHWR BRANCH, TYP.
3-WAY END-OF-LOOP
CONTROL VALVE, TYP.
2-WAY CONTROL VALVE, TYP.
ISOLATION
VALVE, TYP.
AS-85
V
H W
P-1 35 G
PM
4" LPS
F&T
TRAP
2" CR-L
HX-2HX-1
NOTE: SEE PLUMBING DRAWINGS FOR
DOMESTIC WATER CONNECTIONS.
CP-1
M5.11
SIM.
4" 4"
2"
1-1/4"
1-1/4"
1-1/4"
CAP FOR
FUTURE, TYP.
1-1/2"
POT FEEDER
Drawing Title
Approved: Project Director
Project Title
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
Dwg.Revisions: Date
CONSULTANTS: ARCHITECT/ENGINEERS: 437-315
11 / 16 / 2021
Office of Construction and Facilities Management
19.2481.A08 of
EXPAND BLDG. 1 FOR
PRIMARY CARE
CONSTRUCTION DOCUMENTS
FARGO VAHCS
2101 ELM STREET
FARGO, ND 58102
FOURFRONT DESIGN, INC.
517 7TH STREET
RAPID CITY, SOUTH DAKOTA
57701
PH: (605) 342-9470
FAX: (605) 342-2377
WWW.FOURFRONTDESIGN.COMFOUR FRON T
DESIGN IN C.
SUMMIT FIRE CONSULTING
575 MINNEHAHA AVE WEST
ST. PAUL, MINNESOTA 55103
(612) 387-7050
CALIBRE
9090 S RIDGELINE BLVD, SUITE 105
HIGHLANDS RANCH COLORADO 80129
PHONE (303) 730-0434
ALBERTSON ENGINEERING, INC.
315 NORTH MAIN AVENUE, SUITE 200
SIOUX FALLS, SOUTH DAKOTA 57104
PH: (605) 274-0880
#1 ADDENDUM #1 1/4/23
# Revision Number Associated with Clouded Area
PIPING AND INSTRUMENTATION
DIAGRAM (PID)
M 6.01
JBMK 120
AutoCAD SHX Text one eighth inch = one foot
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text B
AutoCAD SHX Text A
AutoCAD SHX Text C
AutoCAD SHX Text D
AutoCAD SHX Text E
AutoCAD SHX Text F
AutoCAD SHX Text 6"
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 6"
AutoCAD SHX Text one and one half inches = one foot
AutoCAD SHX Text one inch = one foot
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 6"
AutoCAD SHX Text 6"
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text three quarters inch = one foot
AutoCAD SHX Text one half inch = one foot
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text three eighths inch = one foot
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text one quarter inch = one foot
AutoCAD SHX Text
VA FORM 08-6231
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text F
AutoCAD SHX Text E
AutoCAD SHX Text D
AutoCAD SHX Text C
AutoCAD SHX Text B
AutoCAD SHX Text A
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
| Sheets |
| M 2.00 - Basement HVAC Plan |
| M 2.01 - First Floor HVAC Plan |
| M 2.10 - Mechanical Roof Plan |
| M 3.10 - HVAC Isometric Views |
| M2481.A08 Fargo PID |
| Sheets and Views |
| M2481.A08 M400 Fargo Mech Schedules-M401 Schedules |
| M2481.A08 Fargo Mech Details-M510-Details |
| M2481.A08 Fargo PID-M601 PID |
File details come from the government source that posted it. Updated .