Addendum Plan SheetsPart-4.pdf
PDF 6 MB Posted
- Solicitation number
- 36C26322R0065
About this file
This document package includes construction drawings and a federal contract opportunity notice. The construction drawings are for Project 636-18-304 to construct a new chiller plant at the Omaha VA Medical Center in Omaha, Nebraska. The drawings show the site plans, utilities plans, and other details for building a new chiller plant to house two centrifugal chillers and relocate a temporary chiller.
The related federal contract opportunity is solicitation number 36C26322R0065 to procure construction services for Project 636-18-304. The estimated construction cost is $10-20 million. The solicitation will be posted on February 8th, 2022 on FedBizOpps with specifications, drawings and bidding instructions. A site visit will be held prior to the March 8th proposal due date. The 550-day period of performance will begin with notice to proceed. The contract is set aside for Service-Disabled Veteran-Owned Small Businesses and the successful bidder must submit bonds within 10 days of award. The Department of Veterans Affairs Veterans Health Administration VISN 23 is the contracting agency.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 36C26322R0065 0004.docx | DOCX document | |
| 36C26322R0065 0003.docx | DOCX document | |
| Addendum specs 040822.pdf | ||
| Addendum Plan SheetsPart-2.pdf | ||
| Addendum Plan SheetsPart-6.pdf | ||
| Addendum Plan SheetsPart-1.pdf | ||
| Addendum 040822.pdf | ||
| Addendum Plan SheetsPart-7.pdf | ||
| Addendum Plan SheetsPart-3.pdf | ||
| Addendum Plan SheetsPart-8.pdf | ||
| Addendum Plan SheetsPart-5.pdf | ||
| Geotechnical Report Terracon no 05215161R01.pdf | ||
| HMS VA Omaha 103119.pdf | ||
| S02_Specs - Volume 1 revised.pdf | ||
| S02_ATTACH - Specs - Volume 2 (1376 pages).pdf | ||
| Omaha VA Chiller photos.pdf | ||
| S02_ATTACH - Drawings (132 pages).pdf | ||
| 36C26322R0065 0002.docx | DOCX document | |
| 36C26322R0065 Final.docx | DOCX document | |
| Site Vist Sign In sheet.pdf | ||
| 36C26322R0065 0001.docx | DOCX document | |
| 36C26322R0065.docx | DOCX document |
Show all 22
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
PhasePROJECT MANAGEMENT STAMPCONSULTANT
FULLY SPRINKLERED
DESIGN
San Antonio, Texas 78217
ARCHITECTURE
8718 BOTTS LANE
Tel: (210) 881-9714
HFS COMPANY
ENGINEERING
Fax: (210) 881-6808 jbianco@hfscompany.com
CONSTRUCTION BID
DOCUMENTS
CONSTRUCT COMBINED
ENERGY PLANT PHASE 1
4101 WOOLWORTH AVE.
OMAHA, NE 68105
11/30/2021
636-18-304 Revisions: Date:
CS-412
SITE PLAN - EROSION CONTROL
AREA 3
NA IAR
SCALE: 1" = 10'19 SITE PLAN - EROSION CONTROL AREA 3
N
KEYED NOTES
1. EXISTING UTILITY TUNNEL.
2. NEW SEGMENTED RETAINING WALL
3. EXIST ACCESS ROAD
4. EXIST MECHANICAL PIPES (DEMOLITION)
5. SILT FENCE
LEGEND
EXISTING UNDERGROUND ELECTRICAL
EXISTING OVERHEAD UTILITY (UNKNOWN)
NEW UNDERGROUND ELECTRICAL
EXISTING STORM DRAIN
NEW STORM DRAIN
EXISTING SANITARY SEWER
NEW SANITARY SEWER
EXISTING STORMDRAIN/SANITARY SEWER
EXISTING WATER
XUE
XOHU
E
NEW WATER
EXISTING GAS
NEW GAS
EXISTING FUEL LINE
NEW FUEL LINE
NEW TECHNOLOGY
XSD
SD
XSS
SS
XSD/SS
XW
W
XG
G
XFL
FL
IT
EXISTING FIRE LINE
NEW FIRE LINE
XF
F
CHAIN LINK FENCE (NEW OR EXISTING)O O O O O O O O O O O O O O O O O O O O O O O O
EXISTING STEAM LINEXST
NEW CHILLED WATER LINECW
XX
GAS VALVE
X FG ###.# SPOT ELEVATION
BOLLARD
FLOW DIRECTION
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
PhasePROJECT MANAGEMENT STAMPCONSULTANT
FULLY SPRINKLERED
DESIGN
San Antonio, Texas 78217
ARCHITECTURE
8718 BOTTS LANE
Tel: (210) 881-9714
HFS COMPANY
ENGINEERING
Fax: (210) 881-6808 jbianco@hfscompany.com
CONSTRUCTION BID
DOCUMENTS
CONSTRUCT COMBINED
ENERGY PLANT PHASE 1
4101 WOOLWORTH AVE.
OMAHA, NE 68105
11/30/2021
636-18-304 Revisions: Date:
CS-413
SITE PLAN - EROSION CONTROL
AREA 4
NA IAR
SCALE: 1" = 10'20 SITE PLAN - EROSION CONTROL AREA 4
UNDERGROUND ELECTRICAL - NEW
UNDERGROUND ELECTRICAL - DEMO
N
KEYED NOTES
1. EXISTING UTILITY TUNNEL.
2. NEW SEGMENTED RETAINING WALL
3. EXIST ACCESS ROAD
4. EXIST MECHANICAL PIPES (DEMOLITION)
5. SILT FENCE
LEGEND
EXISTING UNDERGROUND ELECTRICAL
EXISTING OVERHEAD UTILITY (UNKNOWN)
NEW UNDERGROUND ELECTRICAL
EXISTING STORM DRAIN
NEW STORM DRAIN
EXISTING SANITARY SEWER
NEW SANITARY SEWER
EXISTING STORMDRAIN/SANITARY SEWER
EXISTING WATER
XUE
XOHU
E
NEW WATER
EXISTING GAS
NEW GAS
EXISTING FUEL LINE
NEW FUEL LINE
NEW TECHNOLOGY
XSD
SD
XSS
SS
XSD/SS
XW
W
XG
G
XFL
FL
IT
EXISTING FIRE LINE
NEW FIRE LINE
XF
F
CHAIN LINK FENCE (NEW OR EXISTING)O O O O O O O O O O O O O O O O O O O O O O O O
EXISTING STEAM LINEXST
NEW CHILLED WATER LINECW
XX
GAS VALVE
X FG ###.# SPOT ELEVATION
BOLLARD
FLOW DIRECTION
AREA 4 AREA 3 AREA 2
AREA 1XBLDG. 2
XBLDG. 10
NEW BLDG. X
XBLDG. 17
XBLDG. 23
XBLDG. 15
XBLDG. X
FIN. FLR. @ 1197.00'
XFIN. FLR. @ 1197.03'
XCHILLERS
'PT' BLDG. (NIC)
FUTURE
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
PhasePROJECT MANAGEMENT STAMPCONSULTANT
FULLY SPRINKLERED
DESIGN
San Antonio, Texas 78217
ARCHITECTURE
8718 BOTTS LANE
Tel: (210) 881-9714
HFS COMPANY
ENGINEERING
Fax: (210) 881-6808 jbianco@hfscompany.com 11/30/21
CONSTRUCTION BID
DOCUMENTS
CONSTRUCT COMBINED
ENERGY PLANT PHASE 1
4101 WOOLWORTH AVE.
OMAHA, NE 68105
11/30/2021
636-18-304
ETS
T
TA
GE
S
R I
E T E X
FO
T
CE
TI
H
AS
DER CRA
F. BIAN
C
OJO
SE
P
H
7 6 22 1
Revisions: Date:
CU-100
SITE PLAN - UTILITIES OVERALL
NA IAR
SCALE: 1" = 40'29 SITE PLAN - UTILITIES OVERALL
N
XBLDG. 2
XBLDG. 10
NEW BLDG. X
FIN. FLR. @ 1197.00'
XFIN. FLR. @ 1197.03'
NEW SAS
TIE-IN @
1185.32
NEW SAS MH
RIM 1196.00
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
PhasePROJECT MANAGEMENT STAMPCONSULTANT
FULLY SPRINKLERED
DESIGN
San Antonio, Texas 78217
ARCHITECTURE
8718 BOTTS LANE
Tel: (210) 881-9714
HFS COMPANY
ENGINEERING
Fax: (210) 881-6808 jbianco@hfscompany.com
CONSTRUCTION BID
DOCUMENTS
CONSTRUCT COMBINED
ENERGY PLANT PHASE 1
4101 WOOLWORTH AVE.
OMAHA, NE 68105
11/30/2021
636-18-304 Revisions: Date:
CU-110
SITE PLAN - UTILITIES AREA 1
NA IAR
SCALE: 1" = 10'1 SITE PLAN - UTILITIES AREA 1
N
KEYED NOTES DEMOLITION
1. INTALL130 LF OF NEW 8" PVC SANITARY SEWER.
2. INSTALL 100 LF OF NEW 8" PVC SANITARY SEWER.
3. INSTALL NEW 4' Ø TYPE B MANHOLE
4. INSTALL NEW 4' Ø TYPE B MANHOLE ON EXISTING SEWER LINE.
5. INSTALL NEW 8" C900 FIRE LINE FOR BUILDING. PROVIDE GATE VALVE WITH
NON-RISING STEM.
6. PROVIDE THRUST BLOCKING AT ELBOWS AND FITTINGS.
7. NEW U/G ELECTRIC. REFER TO ELECTRICAL SHEETS.
8. NEW HYDRAULIC LINES. REFER TO MECHANICAL DRAWINGS FOR TIE-IN POINTS.
9. NEW IT LINES
LEGEND
EXISTING UNDERGROUND ELECTRICAL
EXISTING OVERHEAD UTILITY (UNKNOWN)
NEW UNDERGROUND ELECTRICAL
EXISTING STORM DRAIN
NEW STORM DRAIN
EXISTING SANITARY SEWER
NEW SANITARY SEWER
EXISTING STORMDRAIN/SANITARY SEWER
EXISTING WATER
XUE
XOHU
E
NEW WATER
EXISTING GAS
NEW GAS
EXISTING FUEL LINE
NEW FUEL LINE
NEW TECHNOLOGY
XSD
SD
XSS
SS
XSD/SS
XW
W
XG
G
XFL
FL
IT
EXISTING FIRE LINE
NEW FIRE LINE
XF
F
CHAIN LINK FENCE (NEW OR EXISTING)
EXISTING STEAM LINEXST
XX
NEW CHILLER WATER LINESCW
XBLDG. 23
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
PhasePROJECT MANAGEMENT STAMPCONSULTANT
FULLY SPRINKLERED
DESIGN
San Antonio, Texas 78217
ARCHITECTURE
8718 BOTTS LANE
Tel: (210) 881-9714
HFS COMPANY
ENGINEERING
Fax: (210) 881-6808 jbianco@hfscompany.com
CONSTRUCTION BID
DOCUMENTS
CONSTRUCT COMBINED
ENERGY PLANT PHASE 1
4101 WOOLWORTH AVE.
OMAHA, NE 68105
11/30/2021
636-18-304 Revisions: Date:
CU-111
SITE PLAN - UTILITIES AREA 2
NA IAR
SCALE: 1" = 10'32 SITE PLAN - UTILITIES AREA 3 N
KEYED NOTES DEMOLITION
1. INTALL130 LF OF NEW 8" PVC SANITARY SEWER.
2. INSTALL 100 LF OF NEW 8" PVC SANITARY SEWER.
3. INSTALL NEW 4' Ø TYPE B MANHOLE
4. INSTALL NEW 4' Ø TYPE B MANHOLE ON EXISTING SEWER LINE.
5. INSTALL NEW 8" C900 FIRE LINE FOR BUILDING. PROVIDE GATE VALVE WITH
NON-RISING STEM.
6. PROVIDE THRUST BLOCKING AT ELBOWS AND FITTINGS.
7. NEW U/G ELECTRIC. REFER TO ELECTRICAL SHEETS.
8. NEW HYDRAULIC LINES. REFER TO MECHANICAL DRAWINGS FOR TIE-IN POINTS.
9. NEW IT LINES
LEGEND
EXISTING UNDERGROUND ELECTRICAL
EXISTING OVERHEAD UTILITY (UNKNOWN)
NEW UNDERGROUND ELECTRICAL
EXISTING STORM DRAIN
NEW STORM DRAIN
EXISTING SANITARY SEWER
NEW SANITARY SEWER
EXISTING STORMDRAIN/SANITARY SEWER
EXISTING WATER
XUE
XOHU
E
NEW WATER
EXISTING GAS
NEW GAS
EXISTING FUEL LINE
NEW FUEL LINE
NEW TECHNOLOGY
XSD
SD
XSS
SS
XSD/SS
XW
W
XG
G
XFL
FL
IT
EXISTING FIRE LINE
NEW FIRE LINE
XF
F
CHAIN LINK FENCE (NEW OR EXISTING)
EXISTING STEAM LINEXST
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
PhasePROJECT MANAGEMENT STAMPCONSULTANT
FULLY SPRINKLERED
DESIGN
San Antonio, Texas 78217
ARCHITECTURE
8718 BOTTS LANE
Tel: (210) 881-9714
HFS COMPANY
ENGINEERING
Fax: (210) 881-6808 jbianco@hfscompany.com
CONSTRUCTION BID
DOCUMENTS
CONSTRUCT COMBINED
ENERGY PLANT PHASE 1
4101 WOOLWORTH AVE.
OMAHA, NE 68105
11/30/2021
636-18-304 Revisions: Date:
CU-112
NA IAR
SCALE: 1" = 10'1 SITE PLAN - UTILITIES AREA 2
SITE PLAN - UTILITIES AREA 3
N
KEYED NOTES DEMOLITION
1. INTALL130 LF OF NEW 8" PVC SANITARY SEWER.
2. INSTALL 100 LF OF NEW 8" PVC SANITARY SEWER.
3. INSTALL NEW 4' Ø TYPE B MANHOLE
4. INSTALL NEW 4' Ø TYPE B MANHOLE ON EXISTING SEWER LINE.
5. INSTALL NEW 8" C900 FIRE LINE FOR BUILDING. PROVIDE GATE VALVE WITH
NON-RISING STEM.
6. PROVIDE THRUST BLOCKING AT ELBOWS AND FITTINGS.
7. NEW U/G ELECTRIC. REFER TO ELECTRICAL SHEETS.
8. NEW HYDRAULIC LINES. REFER TO MECHANICAL DRAWINGS FOR TIE-IN POINTS.
9. NEW IT LINES
LEGEND
EXISTING UNDERGROUND ELECTRICAL
EXISTING OVERHEAD UTILITY (UNKNOWN)
NEW UNDERGROUND ELECTRICAL
EXISTING STORM DRAIN
NEW STORM DRAIN
EXISTING SANITARY SEWER
NEW SANITARY SEWER
EXISTING STORMDRAIN/SANITARY SEWER
EXISTING WATER
XUE
XOHU
E
NEW WATER
EXISTING GAS
NEW GAS
EXISTING FUEL LINE
NEW FUEL LINE
NEW TECHNOLOGY
XSD
SD
XSS
SS
XSD/SS
XW
W
XG
G
XFL
FL
IT
EXISTING FIRE LINE
NEW FIRE LINE
XF
F
CHAIN LINK FENCE (NEW OR EXISTING)
EXISTING STEAM LINEXST
File details come from the government source that posted it. Updated .