Bldg 39 - Narrative Report.pdf

PDF 198 KB Posted

Attached to
Amendment 0001 - ACM Inspection Service Contract - Fargo
Solicitation number
36C26322Q0029
Issued by

View the file

Other files

File Type Posted
Narrative Report.pdf PDF
Roofing diagram.pdf PDF
Explanation of Attachments.docx DOCX document
Bldg 40 - Narrative Report.pdf PDF
Tunnels - Narrative Report.pdf PDF
36C26322Q0029 0001.pdf PDF
Volume 2.pdf PDF
Bldg 11 - Narrative Report.pdf PDF
Bldg 10 - Narrative Report.pdf PDF
Volume 1.pdf PDF
Attachment 3 - EC-26 Confined Space.docx DOCX document
Bldg 30 - Narrative Report.pdf PDF
Bldg 13 - Narrative Report.pdf PDF
Bldg 12 - Narrative Report.pdf PDF
P15 Drawings.pdf PDF
QA.docx DOCX document
Bldg 3 - Narrative Report.pdf PDF
C03 36C26322Q0029.pdf PDF
Show all 18

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

BUILDING #39

LEGEND No. 0800912

TABLE OF CONTENTS

ITEM

NARRATIVE REPORT

1.0 BUILDING INTRODUCTION

2.0 ASBESTOS SURVEY INFORMATION

2.1 SUSPECT MATERIALS IDENTIFIED AND SAMPLED

2.2 ASBESTOS CONTAINING MATERIALS

LABORATORY DATA

ASBESTOS BULK SAMPLE RESULTS TABLE

ASBESTOS BULK SAMPLE LOCATIONS DIAGRAM

LEGEND No. 0800912 BUILDING #39 Page 1 of 1

1.0 BUILDING INFORMATION

Building #39 was originally constructed in 1978 and has had no major renovations.

The interior floor finishes included concrete; the interior wall finishes included brick; and the interior ceiling finishes included metal. The roofing system is a flat rubber-membrane roof; the exterior of the structure is brick.

Piping systems and HVAC systems were not present.

2.0 ASBESTOS SURVEY INFORMATION

Building #39 was surveyed as part of a larger project for the VA. This report is part of “Volume 2” of a two volume series. This report includes building specific information only; please refer to the opening section of “Volume 2” for methodologies, definitions, and other pertinent supporting information.

A total of 4 samples were collected from suspect asbestos-containing materials (ACM) on November 13, 2008. Laboratory analysis results indicate 0 of these samples tested positive for asbestos.

2.1 Suspect Materials Identified and Sampled

Door/Air Vent System Caulk Building Seam Caulk Penetration Putty Flashing

The Asbestos Bulk Sample Results Table includes asbestos sampling data.

2.2 Asbestos Containing Materials

No asbestos containing materials were detected.

LABORATORY DATA

LEGEND TECHNICAL SERVICES, INC.

ASBESTOS BULK SAMPLE RESULTS TABLE

LEGEND No. 0800912 (VA)

BUILDING #39

MATERIAL/

SAMPLE NO. LAB NO. LOCATION PHYSICAL DESCRIPTION ASBESTOS CONTENT BALANCE OF MATERIAL

< = Less than the number shown Page 1 of 1

1 0800912-XS Exterior North End

Door/Air Vent System Caulk White, Cementitious Homogeneous

None Detected <1% Cellulose 99% Nonfibrous

2 0800912-XT Exterior

West End Building Seam Caulk Gray, Cementitious Homogeneous

None Detected 95% Nonfibrous 5% Glass

3 0800912-XU Exterior East End

Penetration Putty Gray, Cementitious Homogeneous

None Detected 98% Nonfibrous 2% Glass

4 0800912-XV Roof North End

Flashing (on perimeter) Black, Cementitious Homogeneous

None Detected 100% Nonfibrous