S02 ATTACHMENT F_ Drawings Part 2 of 5_Strut-Mech.pdf

PDF 14 MB Posted

Attached to
Z2DA--EHRM GLA Main Campus Construction, Project 691-20-200
Solicitation number
36C26221B0009
Issued by

About this file

This document provides details of an upcoming federal contract opportunity for construction services. The Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 22 will issue an Invitation for Bid between July 13, 2021 and July 27, 2021 for Project 691-20-200, Electronic Health Record Modernization Infrastructure Upgrades at the VA West Los Angeles Healthcare System located in Los Angeles, California. The scope of work includes general construction, alterations, mechanical and electrical work, utility systems, necessary demolition and removal of existing structures. This requirement is valued between $20,000,000 and $50,000,000. The project is set aside 100% for Service-Disabled Veteran-Owned Small Businesses listed in the Vendor Information Pages database. A site visit will be scheduled for potential offerors prior to proposal submission.

View the file

Other files

File Type Posted
S06 Amendment A003_ DWG 527_E-111.pdf PDF
S06 Amendment A003_COR RFIs_Job Walk Roster_DWGs_GLA EHRM CON_36C26221B0009.pdf PDF
S06 Amendment A003_ DWG T-001.pdf PDF
S06 Amendment A003_ DWG 527_T-111.pdf PDF
691-20-200 Telecommunication 100 Final Drawings Part 4 (1) 42 x 30_Part2.pdf PDF
691-20-200 Telecommunication 100 Final Drawings Part 4 (1) 42 x 30_Part6.pdf PDF
691-20-200 Telecommunication 100 Final Drawings Part 4 (1) 42 x 30_Part1.pdf PDF
691-20-200 Telecommunication 100 Final Drawings Part 4 (1) 42 x 30_Part3.pdf PDF
691-20-200 Telecommunication 100 Final Drawings Part 4 (1) 42 x 30_Part7.pdf PDF
691-20-200 Telecommunication 100 Final Drawings Part 4 (1) 42 x 30_Part4.pdf PDF
691-20-200 Telecommunication 100 Final Drawings Part 4 (1) 42 x 30_Part5.pdf PDF
691-20-200 Telecommunication 100 Final Drawings Part 4_1_ 42 x 30_Part3.pdf PDF
691-20-200 Telecommunication 100 Final Drawings Part 4_1_ 42 x 30_Part1.pdf PDF
691-20-200 Elect 100 Final Drawings Part 3_1_ 42 x 30.pdf PDF
691-20-200 Architectural 100 Final Drawings Part 1_ 42 x 30_ Part2.pdf PDF
S06 Amentment A0002_EHRM GLA Main Campus_691-20-200_36C26221B0009.docx DOCX document
691-20-200 Architectural 100 Final Drawings Part 1_ 42 x 30_ Part1.pdf PDF
691-20-200 Strut-Mech 100 Final Drawings Part 2_ 42 x 30.pdf PDF
S06 A0001_Wage Rates_36C26221B0009.pdf PDF
S02 ATTACHMENT E_ Drawings Part 1 of 5_Architectural.pdf PDF
S02 ATTACHMENT C_ Wage Rates 6-25-21.pdf PDF
S02 ATTACHMENT G_ Drawings Part 3 of 5_Elect.pdf PDF
S02 ATTACHMENT B_ Specifications.pdf PDF
S02 ATTACHMENT J_ Facility Map.pdf PDF
S02 ATTACHMENT A_ SOW.pdf PDF
S02 ATTACHMENT I_ Drawings Part 5 of 5_ Telecommunication_Part2.pdf PDF
S02 Solicitation 36C26221B0009_1.pdf PDF
S02 ATTACHMENT D_ GLA Safety Req_Permits_Forms.pdf PDF
S02 ATTACHMENT H_ Drawings Part 4 of 5_ Telecommunication_Part1.pdf PDF
36C26221B0009.docx DOCX document
Show all 30

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

A

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

STAMPCONSULTANT

321 4 5 6 7 8 9 10

Project Director

Revisions: Date:

Key Plan

691-20-200

BS TB

FULLY SPRINKLERED

A

GENERAL NOTES

KEY NOTES

1.

1.

A/E:

ARCHITECT/ENGINEER OF RECORD

D

11301 WILSHIRE BOULEVARD

WEST LOS ANGELES, CA 90073

20801.12

C

B

FINAL CONSTRUCTION

DOCUMENTS

Electronic Health Records Modernization (EHRM) Infrastructure Upgrades -

WLA, CA

June 15, 2021 S-001

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

A

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

STAMPCONSULTANT

321 4 5 6 7 8 9 10

Project Director

Revisions: Date:

Key Plan

691-20-200

BS TB

FULLY SPRINKLERED

A

GENERAL NOTES

KEY NOTES

1.

1.

A/E:

ARCHITECT/ENGINEER OF RECORD

D

11301 WILSHIRE BOULEVARD

WEST LOS ANGELES, CA 90073

20801.12

C

B

FINAL CONSTRUCTION

DOCUMENTS

Electronic Health Records Modernization (EHRM) Infrastructure Upgrades -

WLA, CA

June 15, 2021 S-002

MECHANICAL LEGEND &

ABBREVIATIONS

M-001

ABBREVIATIONSYMBOL DESCRIPTIONABBREVIATION DESCRIPTION ABBREVIATION DESCRIPTION

MECHANICAL ABBREVIATIONS AND LEGEND

ABBREVIATIONSYMBOL DESCRIPTION

ROUND DUCT

ROUND ELBOW ( LONG RADIUS )

12 INCH DIAMETER DUCT12"Ø

STRAIGHT TEE

A

ACM ASBESTOS CONTAINING MATERIALS

A/E ARCHITECT / ENGINEER

ABV ABOVE

AMP AMPERE

B

BHP BRAKE HORSEPOWER

BTU BRITISH THERMAL UNIT

BTUH BRITISH THERMAL UNIT PER HOUR

C

CC COOLING COIL

CD CEILING DIFFUSER

CHW CHILLED WATER

CFM CUBIC FEET PER MINUTE

CG CEILING GRILLE

CP CONDENSATE PUMP

CU CONDENSING UNIT

CW COLD WATER

D

DB DRY-BULB TEMPERATURE

DB DECIBELS

DDC DIRECT DIGITAL CONTROLS

DEG DEGREE

DF DIFFUSER

DN DOWN

DX DIRECT EXCHANGE

DWGS. DRAWINGS

E

(E) EXISTING

EHRM ELECTRONIC HEALTH RECORDS

MODERNIZATION

F

F DEGREES FAHRENHEIT

FT FEET

H

HP HORSEPOWER

HW HOT WATER

HZ HERTZ

I

I/O INPUT/OUTPUT

IN INCHES

J

JCI JOHNSON CONTROL INC.

M

MAX MAXIMUM

MBH 1,000 BTUH

MCA MINIMUM BRANCH CIRCUIT AMPACITY

N

NA NOT APPLICABLE

NAE NETWORK AUTOMATION ENGINE

NC NORMALLY CLOSED

NO NORMALLY OPEN

NTS NOT TO SCALE

R

RA RETURN AIR

REQ. REQUIREMENT

S

SA SUPPLY AIR

SEN SENSIBLE HEAT

SQ FT SQUARE FOOT (FEET)

SS SPLIT SYSTEM

STRUCT. STRUCTURAL

T

TAB TESTING, ADJUSTING AND BALANCING

TD TEMPERATURE DIFFERENCE

THRU THROUGH

TR TELECOMMUNICATION ROOM

TYP TYPICAL

U

UNO UNLESS OTHERWISE NOTED

UTR UP THROUGH ROOF

V

V VALVE

VA VETERAN AFFAIRS

W

W WATTS

WB WET-BULB (TEMPERATURE)

WC WATER COOLED

W/ WITH

1. THESE DRAWINGS ARE A GENERAL GRAPHIC PRESENTATION OF THE WORK. DUCTWORK,

PIPING, AND EQUIPMENT, AS SHOWN, ARE DIAGRAMMATIC. DO NOT SCALE DRAWINGS.

PROVIDE ADDITIONAL OFFSETS AND SECTIONS OF DUCTWORK AND PIPING AS REQUIRED

TO MEET THE PROJECT REQUIREMENTS.

2. COORDINATE WITH OTHER TRADES. PROVIDE A COMPLETE SET OF FABRICATION

DRAWINGS REFLECTING ACTUAL DIMENSIONS, ACCESS REQUIREMENTS, AND DETAILS

BASED UPON THE ACTUAL EQUIPMENT PROCURED. MAINTAIN AN UP TO DATE SET OF

AS-BUILT DRAWINGS AT THE JOB SITE.

3. COMPLY WITH APPLICABLE MECHANICAL CODE, PLUMBING CODE, FIRE PROTECTION

CODE, AND ALL OTHER GOVERNING CODES. THERE SHALL BE NO EXCEPTION. REPORT

DEFICIENCIES WITHIN THIRTY (30) DAYS UPON AUTHORIZATION TO PROCEED.

4. REVIEW ALL DRAWINGS AND SPECIFICATIONS INCLUDING ARCHITECTURAL, STRUCTURAL,

MECHANICAL, PLUMBING, FIRE PROTECTION, TELECOMMUNICATION S AND ELECTRICAL.

ANY QUESTIONS SHALL BE BROUGHT UP, IN WRITING, TO THE ATTENTION OF THE

ENGINEER BEFORE THE START OF CONSTRUCTION.

5. PROVIDE ACCESS AND CLEARANCE FOR MAINTENANCE OF MECHANICAL EQUIPMENT AND

COMPONENTS AS RECOMMENDED BY EQUIPMENT MANUFACTURER AND APPLICABLE

CODES, BUT NO LESS THAN 3 FEET ON ALL SIDES.

6. ALL SEALS, BEARINGS, PACKINGS, AND ACCESSORIES FOR ALL EQUIPMENT AND PIPING

SPECIALTIES SHALL BE SUITABLE FOR THE CONTINUOUS OPERATIONAL TEMPERATURES,

PRESSURES, AND CHARACTERISTICS OF THE SYSTEMS THEY SERVE.

7. HANDLE, STORE, AND INSTALL EQUIPMENT PER MANUFACTURER'S INSTRUCTIONS.

8. SUPPORT PIPING IN ACCORDANCE WITH ANSI/MSS SP-58 PIPE HANGERS AND SUPPORTS -

MATERIALS, DESIGN, MANUFACTURE, SELECTION, APPLICATION, AND INSTALLATION.

9. SUPPORT DUCTWORK IN ACCORDANCE WITH ANSI/SMACNA 006 HVAC DUCT

CONSTRUCTION STANDARDS - METAL AND FLEXIBLE.

10. BRACE PIPING, EQUIPMENT, DUCTWORK, AND CONDUIT IN ACCORDANCE WITH ISAT

DESIGN, INSTALLATION & INSPECTION MANUAL FOR NON-STRUCTURAL SEISMIC BRACING

UNLESS THE AUTHORITY HAVING JURISDICTION HAS ADDITIONAL REQUIREMENTS.

11. COMMISSION AND START-UP THE MECHANICAL SYSTEMS TO ASSURE A COMPLETE AND

OPERATIONAL HVAC SYSTEM IN ACCORDANCE WITH ASHRAE, NEBB, OR AABC.

12. ALL PENETRATIONS THROUGH FIRE RATED CONSTRUCTION SHALL BE FIRE SEALED WITH

UL LISTED THROUGH-PENETRATION SEALING SYSTEMS SUITABLE FOR WALL/FLOOR

ASSEMBLIES AND PENETRATING MATERIAL.

13. MAINTAIN FIRE PROOFING OF STRUCTURAL BEAMS WHERE APPLICABLE.

14. LOCATE ALL ROOF MOUNTED EQUIPMENT IN ACCORDANCE WITH OSHA.

GENERAL NOTES

1. FIELD VERIFY ALL EXISTING CONDITIONS INCLUDING STRUCTURAL, MECHANICAL,

PLUMBING, ELECTRICAL, EQUIPMENT, AND ALL OTHER EXISTING SYSTEMS. MAKE

NECESSARY PROVISIONS TO MAINTAIN THE INTEGRITY OF SYSTEMS PRIOR TO THE

COMMENCEMENT OF DEMOLITION.

2. COORDINATE PHASING OF ALL DEMOLITION AND NEW WORK WITH OTHER TRADES.

REVIEW RENOVATION DRAWINGS TO VERIFY AND DETERMINE EXTENT OF, AND

SCHEDULING FOR, ALL DEMOLITION PRIOR TO PERFORMING ANY WORK.

3. FOR RENOVATION WORK, FIELD VERIFY ALL SIZES, LOCATIONS, AND ROUTING OF

EXISTING ITEMS TO REMAIN, AND OF NEW WORK INDICATED ON THE PLANS. NOTIFY THE

DESIGN AUTHORITY OF ANY DEVIATIONS WHICH MAY AFFECT RENOVATION WORK OR

SYSTEM OPERATION PRIOR TO PROCEEDING WITH THE WORK.

PROJECT NOTES

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Fi le

P at h U.S. Department of Veterans Affairs

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

STAMPCONSULTANT

321 4 5 6 7 8 9 10

Project Director

Revisions: Date:

691-20-200FINAL CONSTRUCTION

DOCUMENTS

June 15, 2021 MS TS / JM

FULLY SPRINKLERED

A

ARCHITECT/ENGINEER OF RECORD

D

17075 Via Del Campo, San Diego, CA 92127 Phone: 858.946.0333

11301 WILSHIRE BOULEVARD

WEST LOS ANGELES, CA 90073

20801.12

Electronic Health Records Modernization (EHRM) Infrastructure Upgrades -

WLA, CA

C

B

POINT OF CONNECTION

POINT OF DISCONNECTPOD

POC

T'STAT

RR

CD

CFM

ER

SYMBOL, SEE EQUIPMENT SCHEDULE

CUBIC FEET PER MINUTE

CEILING DIFFUSER

RETURN REGISTER

EXHAUST REGISTER

HUMIDITY LEVEL SENSOR

THERMOMETERTI

PG

CONTROL VALVE (2-WAY)CV (2W)

CAPPED LINE

VALVE IN RISE

VALVE IN DROP

PIPE UP (RISE)

PIPE DN (DROP)

CD CONDENSATE DRAIN

SHUT-OFF VALVE

UNIONU

STR

FLEXIBLE CONNECTION (PIPE)FC

SUCTION DIFFUSERS

BV

CONTROL VALVE (3-WAY)CV (3W)

BACKFLOW PREVENTERBFP

PRESSURE RELIEF VALVEPR

PRV PRESSURE REDUCING VALVE

THERMOSTAT OR TEMPERATURE SENSOR

(NUMBER INDICATES EQUIPMENT OR

ZONE SERVED)

REMOVE/DEMO EXISTING PIPING

REMOVE/DEMO EXISTING EQUIPMENT

BALANCING VALVE

STRAINER W/ BLOW

DOWN VALVE

PRESSURE GAUGE WITH

SHUTOFF VALVE

TEST WELL (PETE'S PLUG)TW

SOV

CV CHECK VALVE

CONT CONTINUATION

CD

- CFM

T

H

- PHOTO REFERENCE

1 . 1 1 1M -

BUILDING NUMBER

DISCIPLINE

A: ARCHITECTURAL

S: STRUCTURAL

M: MECHANICAL

E: ELECTRICAL

T: TELECOM

SHEET TYPE

1. GENERAL

4. ENLARGED

FLOOR NUMBER

SHEET NUMBER

EXAMPLE

DRAWING NUMBER NOMENCLATURE

TRANSITION - ROUND TO

RECTANGULAR DUCTTRANS.

EXHAUST DUCT DOWNEA

EXHAUST DUCT UPEA

SUPPLY AIR DUCT UPSA

SUPPLY AIR DUCT DOWNSA

T=3'' T

TRANS.

FLEX. CONN. FLEXIBLE DUCT CONNECTION

BD BALANCING DAMPER WITH

LOCKING DEVICE

RETURN AIR

DUCT UP

RETURN AIR

DUCT DOWN

CEILING SUPPLY DIFFUSER

SEE SCHEDULE

FLEXIBLE DUCTWORK

CEILING RETURN GRILLE

SEE SCHEDULE

SIDEWALL REGISTER

SEE SCHEDULE

MANUAL VOLUME DAMPER

RA

RA

MVD

MOTOR OPERATED DAMPERMOD

CEILING EXHAUST GRILLE

SEE SCHEDULE

REMOVE/DEMO EXISTING EQUIPMENT

REMOVE/DEMO EXISTING DUCTWORK

TRANSITION RECTANGULAR DUCT

x1

SPLITTER THROAT SIZE

D CFM

RECTANGULAR DUCT DIMENSIONS

SQUARE ELBOW

RECTANGULAR ELBOW (LONG RADIUS)

HVAC EQUIPMENT SEE SCHEDULE-

C CFM

B CFM

A CFM

1. PROVIDE MECHANICAL SHOP DRAWINGS IN ACCORDANCE WITH GI006.

MECHANICAL SHOP DRAWING NOTES

MECHANICAL SCHEDULES

M-002

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Fi le

P at h U.S. Department of Veterans Affairs

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

STAMPCONSULTANT

321 4 5 6 7 8 9 10

Project Director

Revisions: Date:

691-20-200FINAL CONSTRUCTION

DOCUMENTS

June 15, 2021 MS TS / JM

FULLY SPRINKLERED

A

ARCHITECT/ENGINEER OF RECORD

D

17075 Via Del Campo, San Diego, CA 92127 Phone: 858.946.0333

11301 WILSHIRE BOULEVARD

WEST LOS ANGELES, CA 90073

20801.12

Electronic Health Records Modernization (EHRM) Infrastructure Upgrades -

WLA, CA

C

B

SPLIT SYSTEM SCHEDULE (HEAT PUMP)

INDOOR

SYMBOL AREA SERVED

INDOOR FAN SECTION

OUTDOOR

SYMBOL

OUTDOOR SECTION

MAX.

CFM V Ø Hz

WEIGHT

(LBS) MCA V Ø Hz

WEIGHT

(LBS)

COOLING CAPACITY

MIN

SEER

MAX. PIPING

LENGTH (FT)NOMINAL

TONNAGE

SENS.

CAP.

(MBH)

AMB

(°F)

DETAIL REMARKSREFRIGERANT

TYPE

BLDG 206 ROOM 101 568 1 60 31 13.75 1 60 104 R410A 97.7 14 98

BLDG 206 ROOM 146 1 60 1 60 R410A 97.7

1 60 1 60 R410A 97.7

1 60 1 60 R410A 97.7

1 60 1 60 R410A 97.7

1 60 1 60 R410A 97.7

1 60 R410A 97.7

1 60 1 60 R410A 97.7

1 60 31 13.75 1 60 R410A 97.7

60 1 60 R410A 97.7

1 60 1 60 R410A 97.7

1 60 31 13.75 1 60 R410A 97.7

1 60 31 13.75 1 60 R410A 97.7

1 60 31 1 60 R410A 97.7

1 60 31 1 60 R410A 97.7

1 60 31 1 60 R410A 97.7

1 60 31 1 60 R410A 97.7

1 60 31 1 60 R410A 97.7

1 60 31 1 60 R410A 97.7

1 60 31 1 60 R410A 97.7

1 60 31 1 60 R410A 97.7

1 60 31 1 60 R410A 97.7

1 60 31 1 60 R410A 97.7

1 60 31 1 60 R410A 97.7

1 60 1 60 R410A 97.7 98

1 60 1 60 R410A 97.7

1 60 1 60 R410A 97.7

1.25

DESCRIPTION

DUCTLESS SPLIT SYSTEM

DUCTLESS SPLIT SYSTEM

DUCTLESS SPLIT SYSTEM

DUCTLESS SPLIT SYSTEM

DUCTLESS SPLIT SYSTEM

DUCTLESS SPLIT SYSTEM

DUCTLESS SPLIT SYSTEM

DUCTLESS SPLIT SYSTEM

DUCTLESS SPLIT SYSTEM

DUCTLESS SPLIT SYSTEM

DUCTLESS SPLIT SYSTEM

DUCTLESS SPLIT SYSTEM

DUCTLESS SPLIT SYSTEM

DUCTLESS SPLIT SYSTEM

DUCTLESS SPLIT SYSTEM

DUCTLESS SPLIT SYSTEM

DUCTLESS SPLIT SYSTEM

DUCTLESS SPLIT SYSTEM

DUCTLESS SPLIT SYSTEM

DUCTLESS SPLIT SYSTEM

DUCTLESS SPLIT SYSTEM

DUCTLESS SPLIT SYSTEM

DUCTLESS SPLIT SYSTEM

DUCTLESS SPLIT SYSTEM

DUCTLESS SPLIT SYSTEM

DUCTLESS SPLIT SYSTEM

DUCTLESS SPLIT SYSTEM

DESCRIPTION

CONDENSING UNIT

CONDENSING UNIT

CONDENSING UNIT

CONDENSING UNIT

CONDENSING UNIT

CONDENSING UNIT

CONDENSING UNIT

CONDENSING UNIT

CONDENSING UNIT

CONDENSING UNIT

CONDENSING UNIT

CONDENSING UNIT

CONDENSING UNIT

CONDENSING UNIT

CONDENSING UNIT

CONDENSING UNIT

CONDENSING UNIT

CONDENSING UNIT

CONDENSING UNIT

CONDENSING UNIT

CONDENSING UNIT

CONDENSING UNIT

CONDENSING UNIT

CONDENSING UNIT

CONDENSING UNIT

CONDENSING UNIT

CONDENSING UNIT

BLDG 206 ROOM 244

BLDG 210 ROOM 9

BLDG 210 ROOM 122C

BLDG 210 ROOM 221K

BLDG 213 ROOM B-9

BLDG 213 ROOM 103

BLDG 213 ROOM 201

BLDG 213 ROOM 301

BLDG 214 ROOM B01

BLDG 214 ROOM 205

BLDG 214 ROOM 306

BLDG 215 ROOM B7

BLDG 215 ROOM 123

DUCTLESS SPLIT SYSTEM 1 60 1 60 R410A 97.7 98CONDENSING UNIT

REFER TO THE FOLLOWING SHEET FOR SCHEDULE NOTES.

BLDG 217 ROOM 002

BLDG 217 ROOM 107

BLDG 217 ROOM 202

BLDG 218 ROOM 4

BLDG 218 ROOM 101

BLDG 217 ROOM 302

BLDG 218 ROOM 201

BLDG 220 ROOM 014

BLDG 220 ROOM 121

BLDG 218 ROOM 302

BLDG 220 ROOM 225

1 2 3 4

1 2 3 4

1 2 3 4

1 2 3 4

1 2 3 4

1 2 3 4

1 2 3 4

1 2 3 4

1 2 3 4

1 2 3 4

1 2 3 4

1 2 3 4

1 2 3 4

1 2 3 4

1 2 3 4

1 2 3 4

1 2 3 4

1 2 3 4

1 2 3 4

1 2 3 4

1 2 3 4

1 2 3 4

1 2 3 4

1 2 3 4

1 2 3 4

1 2 3 4

1 2 3 4

1 2 3 4

13.75

13.75

13.75

13.75

13.75

13.75

16.4

13.75

13.75

13.75

13.75

13.75

13.75

13.75

568 1 60 31 104 9813.75 1.25

1.25

1.25

1.25

1.25

1.25

1.25

1.25

1.25

1.25

1.25

2.0

1.25

1.25

1.25

1.25

1.25

1.25

5 6

5 6

5 6

5 6

5 6

5 6

5 6

5 6

5 6

5 6

5 6

5 6

5 6

5 6

5 6

5 6

5 6

5 6

5 6

5 6

5 6

5 6

5 6

5 6

5 6

5 6

5 6

B5 / M-501

B5 / M-501

B5 / M-501

B5 / M-501

B5 / M-501

B5 / M-501

B5 / M-501

B5 / M-501

B5 / M-501

B5 / M-501

B5 / M-501

B5 / M-501

B5 / M-501

B5 / M-501

B5 / M-501

B5 / M-501

B5 / M-501

B5 / M-501

B5 / M-501

B5 / M-501

B5 / M-501

B5 / M-501

B5 / M-501

B5 / M-501

B5 / M-501

B5 / M-501

B5 / M-501

B5 / M-501

568 31 13.75 104 981.25

568 31 13.75 104 981.25

568 31 13.75 104 981.25

568 31 13.75 104 981.25

568 31 13.75 104 981.25

568 31 13.75 104 981.25

568 31 13.75 104 981.25

98568 31 13.75 104 1.25

98568 31 13.75 104 1.25

SS

210-9

CU

210-9

SS

210-122C

CU

210-122C

SS

210-221K

CU

210-221K

SS

213-B-9

CU

213-B-9

SS

213-103

CU

213-103

SS

213-201

CU

213-201

SS

213-301

CU

213-301

SS

214-1

CU

214-1

SS

214-205

CU

214-205

SS

214-306

CU

214-306

SS

215-B7

CU

215-B7

SS

215-123

CU

215-123

SS

215-233

CU

215-233

SS

215-333

CU

215-333

SS

217-002

CU

217-002

SS

217-107

CU

217-107

SS

217-202

CU

217-202

SS

217-302

CU

217-302

SS

218-4

CU

218-4

SS

218-101

CU

218-101

SS

218-201

CU

218-201

SS

218-302

CU

218-302

SS

220-121

CU

220-121

SS

220-225

CU

220-225

SS

220-332

CU

220-332

SS

256-1

CU

256-1

SS

256-102

CU

256-102

SS

256-226

CU

256-226

SS

257-1

CU

257-1

SS

257-135

CU

257-135

SS

257-215

CU

257-215

SS

258-104A

CU

258-104A

SS

258-120

CU

258-120

SS

258-210A

CU

258-210A

SS

220-014

CU

220-014

SS

206-101

CU

206-101

SS

206-146

CU

206-146

SS

206-224

CU

206-244

10.0

9.3

7.3

7.5

7.3

7.3

12.4

4.6

6.9

7.4

6.9

4.5

4.5

4.8

4.7

2.3

4.8

4.6

7.1

7.3

7.2

5.1

7.0

7.3

7.3

9.9

11.9

9.5

9.5

10.0

15.0

9.4

9.6

10.0

1 60 31 1 60 R410A 97.7

1 60 31 1 60 R410A 97.7

1 60 31 1 60 R410A 97.7

DUCTLESS SPLIT SYSTEM

DUCTLESS SPLIT SYSTEM

DUCTLESS SPLIT SYSTEM

CONDENSING UNIT

CONDENSING UNIT

CONDENSING UNIT

BLDG 220 ROOM 332

BLDG 256 ROOM 1

BLDG 256 ROOM 102

1 2 3 4

1 2 3 4

1 2 3 4

13.75

13.75

13.75

1.25

1.25

1.25

5 6

5 6

5 6

B5 / M-501

B5 / M-501

B5 / M-501

1 60 31 1 60 R410A 97.7

1 60 31 1 60 R410A 97.7

1 60 31 1 60 R410A 97.7

DUCTLESS SPLIT SYSTEM

DUCTLESS SPLIT SYSTEM

DUCTLESS SPLIT SYSTEM

CONDENSING UNIT

CONDENSING UNIT

CONDENSING UNIT

BLDG 256 ROOM 226

BLDG 257 ROOM

BLDG 257 ROOM 135

1 2 3 4

1 2 3 4

1 2 3 4

13.75

13.75

13.75

1.25

1.25

1.25

5 6

5 6

5 6

B5 / M-501

B5 / M-501

B5 / M-501

1 60 31 1 60 R410A 97.7

1 60 31 1 60 R410A 97.7

1 60 31 1 60 R410A 97.7

DUCTLESS SPLIT SYSTEM

DUCTLESS SPLIT SYSTEM

DUCTLESS SPLIT SYSTEM

CONDENSING UNIT

CONDENSING UNIT

CONDENSING UNIT

BLDG 257 ROOM 215

BLDG 258 ROOM 104A

BLDG 258 ROOM 120

1 2 3 4

1 2 3 4

1 2 3 4

13.75

13.75

13.75

1.25

1.25

1.25

5 6

5 6

5 6

B5 / M-501

B5 / M-501

B5 / M-501

1 60 31DUCTLESS SPLIT SYSTEM BLDG 258 ROOM 210A 568 208 1 60 R410A 97.7 98CONDENSING UNIT 13.75 104 1.25 14208 B5 / M-501 1 2 3 4 5 6 7

BLDG 215 ROOM 233

BLDG 215 ROOM 333

7.3

4.7

4.6

4.8

MCA

M-003

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Fi le

P at h U.S. Department of Veterans Affairs

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

STAMPCONSULTANT

321 4 5 6 7 8 9 10

Project Director

Revisions: Date:

691-20-200FINAL CONSTRUCTION

DOCUMENTS

June 15, 2021 MS TS / JM

FULLY SPRINKLERED

A

ARCHITECT/ENGINEER OF RECORD

D

17075 Via Del Campo, San Diego, CA 92127 Phone: 858.946.0333

11301 WILSHIRE BOULEVARD

WEST LOS ANGELES, CA 90073

20801.12

Electronic Health Records Modernization (EHRM) Infrastructure Upgrades -

WLA, CA

C

B

SPLIT SYSTEM SCHEDULE (HEAT PUMP) (CONTINUED)

SYMBOL AREA SERVED

INDOOR FAN SECTION

SYMBOL

OUTDOOR SECTION

MAX.

CFM V Ø Hz

WEIGHT

(LBS) MCA V Ø Hz

WEIGHT

(LBS)

COOLING CAPACITY

MIN

SEER

MAX. PIPING

LENGTH (FT)NOMINAL

TONNAGE

SENS.

CAP.

(MBH)

AMB

(°F)

DETAIL REMARKSREFRIGERANT

TYPE

BLDG 258 ROOM 215 568 1 60 31 13.75 1 60 104 R410A 97.7 98

BLDG 258 ROOM 335 1 60 1 60 R410A 97.7

1 60 1 60 R410A 97.7

1 60 1 60 R410A 97.7

1 60 1 60 R410A 97.7

1 60 1 60 R410A 97.7

1 60 R410A 97.7

1 60 1 60 R410A 97.7

1 60 31 13.75 1 60 R410A 97.7

60 1 60 R410A 97.7

1 60 1 60 R410A 97.7

1 60 31 13.75 1 60 R410A 97.7

1 60 31 1 60 R410A 97.7

1 60 31 1 60 R410A 97.7

1 60 31 1 60 R410A 97.7

1 60 31 1 60 R410A 97.7

1 60 31 1 60 R410A 97.7

1 60 31 1 60 R410A 97.7

1 60 31 1 60 R410A 97.7

1 60 31 1 60 R410A 97.7

1 60 31 1 60 R410A 97.7

1 60 1 60 R410A 97.7 98

1 60 1 60 R410A 97.7

1 60 1 60 R410A 97.7

1.25

DESCRIPTION

DUCTLESS SPLIT SYSTEM

DUCTLESS SPLIT SYSTEM

DUCTLESS SPLIT SYSTEM

DUCTLESS SPLIT SYSTEM

DUCTLESS SPLIT SYSTEM

DUCTLESS SPLIT SYSTEM

DUCTLESS SPLIT SYSTEM

DUCTLESS SPLIT SYSTEM

DUCTLESS SPLIT SYSTEM

DUCTLESS SPLIT SYSTEM

DUCTLESS SPLIT SYSTEM

DUCTLESS SPLIT SYSTEM

DUCTLESS SPLIT SYSTEM

DUCTLESS SPLIT SYSTEM

DUCTLESS SPLIT SYSTEM

DUCTLESS SPLIT SYSTEM

DUCTLESS SPLIT SYSTEM

DUCTLESS SPLIT SYSTEM

DUCTLESS SPLIT SYSTEM

DUCTLESS SPLIT SYSTEM

DUCTLESS SPLIT SYSTEM

DUCTLESS SPLIT SYSTEM

DUCTLESS SPLIT SYSTEM

DUCTLESS SPLIT SYSTEM

DESCRIPTION

CONDENSING UNIT

CONDENSING UNIT

CONDENSING UNIT

CONDENSING UNIT

CONDENSING UNIT

CONDENSING UNIT

CONDENSING UNIT

CONDENSING UNIT

CONDENSING UNIT

CONDENSING UNIT

CONDENSING UNIT

CONDENSING UNIT

CONDENSING UNIT

CONDENSING UNIT

CONDENSING UNIT

CONDENSING UNIT

CONDENSING UNIT

CONDENSING UNIT

CONDENSING UNIT

CONDENSING UNIT

CONDENSING UNIT

CONDENSING UNIT

CONDENSING UNIT

CONDENSING UNIT

BLDG 258 ROOM 404

BLDG 304 ROOM 2-2

BLDG 304 ROOM 106B

BLDG 304 ROOM 2-223A

BLDG 304 ROOM 224

BLDG 345 ROOM 39A

BLDG 401 ROOM A100G

BLDG 401 ROOM A-239

BLDG 402 ROOM 2413

BLDG 507 ROOM 102

BLDG 527 ROOM 22

BLDG 527 ROOM 23

DUCTLESS SPLIT SYSTEM 1 60 1 60 R410A 97.7 164CONDENSING UNIT

PROVIDE FACTORY WIRED WALL-MOUNTED THERMOSTAT.

1 2 3 4

1 2 3 4

1 2 3 4

1 2 3 4

1 2 3

1 2 3 4

1 2 3 4

1 2 3 4

1 2 3 4

1 2 3 4

1 2 3 4

1 2 3

1 2 3 4

1 2 3 4

1 2 3

1 2 3

1 2 3

1 2 3

1 2 3

1 2 3

1 2 3

1 2 3

1 2 3

1 2 3

1 2 3

DO NOT EXCEED MANUFACTURER'S LISTED MAXIMUM PIPING LENGTH REQUIREMENTS. COORDINATE SELECTION WITH ACTUAL LENGTHS FROM SHOP DRAWINGS.

PROVIDE W/ FACTORY PROVIDED FIELD INSTALLED CONDENSATE PUMP.1 2 3 4 INDOOR UNIT POWERED FROM THE OUTDOOR UNIT. REFER TO ELECTRICAL

55 PROVIDE PER APPLICABLE OSP.

31 13.75

568 1 60 31 104 9813.75 1.25

1.25

1.25

1.25

6 VERIFY AND COORDINATE CONNECTION SIDE PRIOR TO PROCUREMENT.

5 6

5 6

5 6

5 6

5 6

5 6

5 6

5 6

5 6

5 6

5 6

5 6

5 6

5 6

5 6

5 6

5 6

5 6

5 6

5 6

5 6

5 6

5 6

5 6

7 PROVIDE WITH INTEGRAL OVERFLOW ALARM TO SHUFT OFF THE EVAPORATOR IN CASE OF BLOCKAGE OR FAILURE.

B5 / M-501

B5 / M-501

B5 / M-501

B5 / M-501

B5 / M-501

B5 / M-501

B5 / M-501

B5 / M-501

B5 / M-501

B5 / M-501

B5 / M-501

B5 / M-501

B5 / M-501

B5 / M-501

B5 / M-501

B5 / M-501

B5 / M-501

B5 / M-501

B5 / M-501

B5 / M-501

B5 / M-501

B5 / M-501

B5 / M-501

B5 / M-501

B5 / M-501

568 31 13.75 104 981.25

568 31 13.75 104 981.25

568 31 13.75 104 981.25

568 31 13.75 104 981.25

568 31 13.75 104 981.25

568 31 13.75 104 981.25

98568 31 13.75 104 1.25

16431 172

2.0

7.8

9.9

10.6

7.2

11.9

8.2

1.9

13.4

16.4

18.2

7.2

4.6

4.6

SS

258-215

CU

258-215

SS

258-335

CU

258-335

SS

258-404

CU

258-404

SS

304-2-2

CU

304-2-2

SS

304-2-106B

CU

304-2-106B

SS

304-2-223A

CU

304-2-223A

SS

304-224

CU

304-224

SS

345-39A

CU

345-39A

SS

401-A100G

CU

401-A100G

SS

401-A-239

CU

401-A-239

SS

402-2413

CU

402-2413

SS

507-102

CU

507-102

SS

527-22

CU

527-22

SS

527-23

CU

527-23

10.8

12.6

SS

500-10IN

SS

500-10IS

SS

500-11IN

SS

500-11IS

SS

500-12IN

SS

500-12IS

SS

500-13IN

SS

500-13IS

SS

500-14IN

SS

500-14IS

SS

500-15IN

SS

500-15IS

SS

500-16IN

SS

500-16IS

DUCTLESS SPLIT SYSTEM

DUCTLESS SPLIT SYSTEM

DUCTLESS SPLIT SYSTEM

CU

500-10IN

CU

500-10IS

CU

500-11IN

CU

500-11IS

CU

500-12IN

CU

500-12IS

CU

500-13IN

CU

500-13IS

CU

500-14IN

CU

500-14IS

CU

500-15IN

CU

500-15IS

CU

500-16IN

CU

500-16IS

13.4

13.4

13.4

13.4

13.4

13.4

13.4

13.4

13.4

13.4

13.4

13.4

13.4

1 2 3

1 2 3

1 2 3

5 6

5 6

5 6

1 60 R410A

1 60 R410A

1 60 R410A

208 172

2.0

CONDENSING UNIT

CONDENSING UNIT

CONDENSING UNIT

97.7

97.7

97.7

B5 / M-501

B5 / M-501

B5 / M-501

1 60 31

1 60

1 60 31

31 16.5

16.5

16.5

16.5

16.5

16.5

16.5

16.5

16.5

16.5

16.5

16.5

16.5

16.5

BLDG 500 ROOM 10IN

BLDG 500 ROOM 10IS

BLDG 500 ROOM 11IN

BLDG 500 ROOM 11IS

BLDG 500 ROOM 12IN

BLDG 500 ROOM 12IS

BLDG 500 ROOM 13IN

BLDG 500 ROOM 13IS

BLDG 500 ROOM 14IN

BLDG 500 ROOM 14IS

BLDG 500 ROOM 15IN

BLDG 500 ROOM 15IS

BLDG 500 ROOM 16IN

BLDG 500 ROOM 16IS

2.0

2.0

2.0

2.0

2.0

2.0

2.0

2.0

2.0

2.0

2.0

2.0

635 1642.017216.5

635 17216.5 1642.0

0.6

0.6

0.6

0.6

0.6

0.6

0.6

0.6

0.6

0.6

0.6

0.6

0.6

0.6

0.6

0.6

MCA

M-004

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Fi le

P at h U.S. Department of Veterans Affairs

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

STAMPCONSULTANT

321 4 5 6 7 8 9 10

Project Director

Revisions: Date:

691-20-200FINAL CONSTRUCTION

DOCUMENTS

June 15, 2021 MS TS / JM

FULLY SPRINKLERED

A

ARCHITECT/ENGINEER OF RECORD

D

17075 Via Del Campo, San Diego, CA 92127 Phone: 858.946.0333

11301 WILSHIRE BOULEVARD

WEST LOS ANGELES, CA 90073

20801.12

Electronic Health Records Modernization (EHRM) Infrastructure Upgrades -

WLA, CA

C

B

DESCRIPTIONSYMBOL

CFM

SUPPLY FAN

QTY

AREA SERVED

FC

HP

REMARKS

V PHHZ

COOLING COIL

DB WB

LAT (F°)

DB WB

GPM

MINIMUM

NOMINAL

TONNAGE

SENSIBLE

CAPACITY

(MBH)

PROVIDE SECONDARY CONDENSATE PAN AND CONDENSATE PAN OVERFLOW SWITCH BY FAN COIL MANUFACTURER.

208 60 1

WITH EC MOTOR.1 2

1 2

AMPS

FC BLDG 500 ROOM 10SD 208 60 1 1 2

FC 208 60 1 1 2

FC 208 60 1 1 2

FC 208 60 1 1 2

FC 208 60 1 1 2

FC 208 60 1 1 2

FC 208 60 1 1 2

FC 208 60 1 1 2

FC 208 60 1 1 2

FC 208 60 1 1 2

FC 208 60 1 1 2

FC 208 60 1 1 2

FC 208 60 1 1 2

FC 208 60 1 1 2

BLDG 500 ROOM 10SJ

BLDG 500 ROOM 10SA

BLDG 500 ROOM 10SH

BLDG 500 ROOM 11SE

BLDG 500 ROOM 11SO

BLDG 500 ROOM 12SE

BLDG 500 ROOM 13SA

BLDG 500 ROOM 13SE

BLDG 500 ROOM 14SE

BLDG 500 ROOM 14SA

BLDG 500 ROOM 15SA

BLDG 500 ROOM 15SE

BLDG 500 ROOM 16SA

BLDG 500 ROOM 16SE

FC 208 60 1 1 2BLDG 500 ROOM 11SN

1.25825 4 13.41.9EXPOSED SUSPENDED CHW FAN COIL

EXPOSED SUSPENDED CHW FAN COIL

EXPOSED SUSPENDED CHW FAN COIL

EXPOSED SUSPENDED CHW FAN COIL

EXPOSED SUSPENDED CHW FAN COIL

EXPOSED SUSPENDED CHW FAN COIL

EXPOSED SUSPENDED CHW FAN COIL

EXPOSED SUSPENDED CHW FAN COIL

EXPOSED SUSPENDED CHW FAN COIL

EXPOSED SUSPENDED CHW FAN COIL

EXPOSED SUSPENDED CHW FAN COIL

EXPOSED SUSPENDED CHW FAN COIL

EXPOSED SUSPENDED CHW FAN COIL

EXPOSED SUSPENDED CHW FAN COIL

EXPOSED SUSPENDED CHW FAN COIL

EXPOSED SUSPENDED CHW FAN COIL

(2) 1/4

MIN.

ROWS

3 70

EWT

(F°)

LWT

(F°)

BRANCH

SIZE

1.9 44

MAX.

WATER PD

(FT)

MAX.

OPER.

WEIGHT

(LBS)

MOUNTING

DETAIL

55 58 55 58 3/4 13.1 81 C8 / M-502

1.25825 4 13.41.9 (2) 1/4 3 70 1.9 4455 58 55 58 3/4 13.1 81 C8 / M-502

1.25825 4 13.41.9 (2) 1/4 3 70 1.9 4455 58 55 58 3/4 13.1 81 C8 / M-502

1.25825 4 13.41.9 (2) 1/4 3 70 1.9 4455 58 55 58 3/4 13.1 81 C8 / M-502

1.25 13.4 3 70 1.9 4455 58 55 58 3/4 13.1 81 C8 / M-502

1.25 13.4 3 70 1.9 4455 58 55 58 3/4 13.1 81 C8 / M-502

1.25 13.4 3 70 1.9 4455 58 55 58 3/4 13.1 81 C8 / M-502

1.25 13.4 3 70 1.9 4455 58 55 58 3/4 13.1 81 C8 / M-502

1.25 13.4 3 70 1.9 4455 58 55 58 3/4 13.1 81 C8 / M-502

1.25 13.4 3 70 1.9 4455 58 55 58 3/4 13.1 81 C8 / M-502

1.25 13.4 3 70 1.9 4455 58 55 58 3/4 13.1 81 C8 / M-502

1.25 13.4 3 70 1.9 4455 58 55 58 3/4 13.1 81 C8 / M-502

1.25 13.4 3 70 1.9 4455 58 55 58 3/4 13.1 81 C8 / M-502

1.25 13.4 3 70 1.9 4455 58 55 58 3/4 13.1 81 C8 / M-502

1.25 13.4 3 70 1.9 4455 58 55 58 3/4 13.1 81 C8 / M-502

1.25 13.4 3 70 1.9 4455 58 55 58 3/4 13.1 81 C8 / M-502

825 4 1.9 (2) 1/4

825 4 1.9 (2) 1/4

825 4 1.9 (2) 1/4

825 4 1.9 (2) 1/4

825 4 1.9 (2) 1/4

825 4 1.9 (2) 1/4

825 4 1.9 (2) 1/4

825 4 1.9 (2) 1/4

825 4 1.9 (2) 1/4

825 4 1.9 (2) 1/4

825 4 1.9 (2) 1/4

825 4 1.9 (2) 1/4

EAT (F°)

FAN COIL SCHEDULE

500-10SJ

500-10SD

500-10SA

500-11SH

500-11SE

500-11SO

500-12SE

500-13SA

500-13SE

500-14SE

500-14SA

500-15SA

500-15SE

500-16SA

500-16SE

500-11SN

NON DUCTED.3 PROVIDE PER APPLICABLE OSP.4 PROVIDE FACTORY MOUNTED CONDENSATE PUMP WITH SINGLE POINT POWER.5

VERIFY AND COORDINATE CONNECTION SIDE PRIOR TO PROCUREMENT.6

SERVICE

AIR DISTRIBUTION SCHEDULE

SYMBOL

6"Ø 0-95

MOUNTING

SURFACE

T-BAR/

HARD

CEILING

DESCRIPTION

4-WAY,

MODULAR

CORE CEILING

DIFFUSER

NECK

SIZE PHOTO

NECK

SIZE

T-BAR/

HARD

CEILING

SUPPLY

AIR

RETURN

AIR

REMARKS

ALUMINUM

CONSTRUCTION

ALUMINUM

CONSTRUCTION

MATCH

EXISTING

ADJACENT

STYLE

8"Ø 95-210

10"Ø 210-370

12"Ø 370-600

14"Ø 600-900

16"Ø 900-1,290

8"Ø 190

10"Ø 340

12"Ø 560

14"Ø 890

16"Ø 1,190

18"Ø 1,610

CFM

RANGE

MAX

CFM

A CFM

B CFM

WITH BOTTOM RETURN.7

RA

MP

U P

RAMP UP

CHAIN LINK CAGE

RAMP UP

EXIT DOOR

A B C D E F G H

3.2

1.1

MEN'S

RR

WOMEN'S

RR

ELEV

LOBBY

ELEV

ELEV

MACH RM

MEN'S

SHOWER

INTAKE

RM

VESTING

OFFICE

SOCIAL WORKER

OFFICE

ELIGIBILITY

CLERK OFFICE

ELIGIBILITY

CLERK OFFICE

SCREENING

RM

RECEPTION

SCREENING

RM

WORK

AREA

014A

PSYCHIATRIST

CLINICAL

CO-ORDR

SCREENING

CLINIC

OFFICE OF

SCREENING CLERK

CL

QUIET

RM

CLINICAL SUPPORT

OFFICE

CLINICAL SUPPORT

PGM MGR OFFICE

OUTREACH

COMMUNITY CARE

STORAGE

018A

STAFF

KITCHEN

OFFICE

STAIR

SUPPLY

RM

STORAGE

OFFICE

SOCIAL

WORKER OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

034A

OFFICE

SOCIAL WORKER

OFFICE

SOCIAL WORKER

OFFICE

SOCIAL WORKER

OFFICE

SOCIAL WORKER

OFFICE

GRANT PER DIEM

LIAISON OFFICE

BENEFIT &

COUNSELOR OFFICE

COPY

RM

CLINICAL STAFF

GRANT PER DIEM

STEAM RM

STAIR

CORRIDOR

TELECOM

ROOM

ELECTRICAL

ROOM

001A

C1 206.M-401

CU

206-101

E1 206.M-401

3/4" CD

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Fi le

P at h U.S. Department of Veterans Affairs

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

STAMPCONSULTANT

321 4 5 6 7 8 9 10

Project Director

Revisions: Date:

Key Plan

691-20-200FINAL CONSTRUCTION

DOCUMENTS

June 15, 2021 MS TS / JM

FULLY SPRINKLERED

A

GENERAL NOTES

KEY NOTES

ARCHITECT/ENGINEER OF RECORD

D

17075 Via Del Campo, San Diego, CA 92127 Phone: 858.946.0333

11301 WILSHIRE BOULEVARD

WEST LOS ANGELES, CA 90073

20801.12

Electronic Health Records Modernization (EHRM) Infrastructure Upgrades -

WLA, CA

C

B

206.M-101

MECHANICAL BASEMENT FLOOR

PLAN - BUILDING 206 BUILDING 206

MECHANICAL BASEMENT FLOOR PLAN - BUILDING 206F1 SCALE:

NORTH

SCALE: 1/8" = 1'-0"

1. DISCHARGE CONDENSATE DRAIN TO LAVATORY

TAILPIECE. SEE DETAIL F8/M-501.

2. PROVIDE CODE REQUIRED AND MANUFACTURER'S

RECOMMENDED EQUIPMENT CLEARANCE.

3. PROVIDE CONCRETE HOUSEKEEPING PAD.

1. RS/RL SIZED PER MANUFACTURER'S RECOMMENDATIONS.

2. REFER TO M-80X FOR PHOTO REFERENCES ( ).

3. ROUTE CONDENSATE DRAIN PIPING CONCEALED ABOVE

CEILING, EXCEPT IN JANITORS CLOSET / HOUSEKEEPING

ROOMS WITH HARD LID CEILINGS. PATCH AND REPAIR

CEILING WHERE REQUIRED TO PENETRATE CEILING.

4. RS/RL ROUTING IS SHOWN FOR REFERENCE.

ALTERNATIVE ROUTING MAY BE USED BASED ON

COORDINATED SHOP DRAWINGS AND IN ACCORDANCE

WITH MANUFACTURER'S REQUIREMENTS.

1A

0' 4' 8' 16'

DN

DN

UP UP

A B C D E F G H

3.2

1.1

RA

MP

D

OW

N

DN

DN

ROLL DOWN DOOR

TELECOM

ROOM

SOCIAL WORKER

OFFICE

CHAPLAIN

MED RM

RECEPTION

VA SUPPORT

HOUSING OFFICE

VA SUPPORT

HOUSING OFFICE

PGM

MGR

CONFERENCE

RM

STAIR

CORRIDOR

GRANT PER DIEM

NURSING LIAISON

PGM

SPECIALIST

112BHCRV DEPUTY

PGM MGR

112A

PIPE SPACE

CORR

WASH RM

& TOILET

SHOWER RM

113A

ASSOC. OFFICE NURSE COMM/

PRIMARY & AMBULATORY CARE

PIPE SPACE

ELEC RM

SOCIAL

WORKER

SOCIAL

WORKER

CHIEF OF

MENTAL HEALTH

SOCIAL SCIENCE

PGM SPECIALIST

119A

GRANT PER

DIEM OFFICE

ADMIN

OFFICER

CORR

CORR

STAIR-2

STAIR-3

STAIR

WAITING

RM

MENTAL HEALTH CLINICAL

PHARMACIST

EMS

121A

EMS

MEN'S

STAFF RR

ADMIN

SUPPORT

HEAD

NURSE

COMPUTER RM

W. RR

SOCIAL

SVC

QUALITY

MGMT

PGM MGR

NURSE

MGR

130 CHIEF OF

COMM CARE

CORR

CHIEF OF

COMM CARE

CLINICAL

KITCHEN

CORR

MEN'S TOILET

CORR

P. S.

135A

LOCKERS

SELF CHECK IN

PIPE CHASE

TRIAGE

CARE MGR

MEN

STAFF RR

CORR

EMS

EXAM

RM-10

14-

ELEV

MEDICATION

RM

PRIMARY CARE

CLINIC

LAB

NURSES

OFFICE

143A

PHYSICIAN ASST

OFFICE

CORR

WAITING RM

PTSD PGM

CORR

IT/COMM RM

STORAGE RM

147A

PIPE SPACE

H/C WOMEN'S

WASH RM & TOILET

EXAM

RM-8

EXAM

RM-6

EXAM

RM-4

149A

EXAM

RM-1

MULTI PURPOSE

RM

STAIR

CORRIDOR

DOCTORS

OFFICE

DOCTORS

OFFICE

RNS

OFFICE

153A

NURSES

OFFICE

153B

NURSES

STATION

HEAD

NURSE

WAITING

RM

CLINICAL

PHARMACIST

WHITE TEAM

TRIAGE

TOILET

158A

TOILET

CORR

P. S.

STORAGE

RM 147A

CU

206-244

CU

206-146

3/4" CD

C4 206.M-401

E4 206.M-401

(TYP)

(TYP)

CD

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Fi le

P at h U.S. Department of Veterans Affairs

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

STAMPCONSULTANT

321 4 5 6 7 8 9 10

Project Director

Revisions: Date:

Key Plan

691-20-200FINAL CONSTRUCTION

DOCUMENTS

June 15, 2021 MS TS / JM

FULLY SPRINKLERED

A

GENERAL NOTES

KEY NOTES

ARCHITECT/ENGINEER OF RECORD

D

17075 Via Del Campo, San Diego, CA 92127 Phone: 858.946.0333

11301 WILSHIRE BOULEVARD

WEST LOS ANGELES, CA 90073

20801.12

Electronic Health Records Modernization (EHRM) Infrastructure Upgrades -

WLA, CA

C

B

206.M-111

MECHANICAL FIRST FLOOR PLAN -

BUILDING 206 BUILDING 206

MECHANICAL FIRST FLOOR PLAN - BUILDING 206F1 SCALE:

NORTH

0' 4' 8' 16'SCALE: 1/8" = 1'-0"

1. CONDENSATE DRAIN DISCHARGE TO UTILITY SINK.

SEE DETAIL F5/M-501.

2. PROVIDE CODE REQUIRED AND MANUFACTURER'S

RECOMMENDED EQUIPMENT CLEARANCE.

3. PROVIDE CONCRETE HOUSEKEEPING PAD.

1. RS/RL SIZED PER MANUFACTURER'S RECOMMENDATIONS.

2. REFER TO M-80X FOR PHOTO REFERENCES ( ).

3. ROUTE CONDENSATE DRAIN PIPING CONCEALED ABOVE

CEILING, EXCEPT IN JANITORS CLOSET / HOUSEKEEPING

ROOMS WITH HARD LID CEILINGS. PATCH AND REPAIR

CEILING WHERE REQUIRED TO PENETRATE CEILING.

4. RS/RL ROUTING IS SHOWN FOR REFERENCE.

ALTERNATIVE ROUTING MAY BE USED BASED ON

COORDINATED SHOP DRAWINGS AND IN ACCORDANCE

WITH MANUFACTURER'S REQUIREMENTS.

1B

1C

C

DN DN

A B D E F G H

3.2

1.1

DN

UP TO ATTIC

FE

TELECOM

ROOM

GROUP

RM

STAIR

STAIR-2

STAIR-3

STAIR

STAIR

STAFF

PSYCHIATRIST

SOCIAL

WORKER

REGISTERED

NURSE

CORR

STAFF

PSYCHIATRIST

STAFF

PSYCHIATRIST

CORRIDOR

WAITING

RM

ADMIN

ASST

OFFICE

CLINICAL OPERATION

OFFICE

PSYCHOLOGIST

STAFF

PSYCHIATRIST

TREATMENT

RM

RN SUPPLY

RM

ELEV STAFF

KITCHEN

CONFERENCE RM /

GROUP RM

RESEARCH

ASST

WAITING

RM

STAFF

PSYCHIATRIST

REGISTERED

NURSE

CORR

DAY

RM

STAFF

PSYCHIATRIST

STAFF

PSYCHIATRIST

NURSE

PRACTITIONER

P. S.

MEN'S WASH RM

& TOILET

P. S.

IT/COMM

RM

STORAGE

RM

245A

STAFF PSYCHIATRIST

RN

SOCIAL

WORKER

CORR

TEAM CARE

CO-ORDR

CALL CENTER

OFFICE

STAFF

PSYCHIATRIST

CORR

CORR

CORR

CORR

--- HAC

BMS

237A

STAFF

LOUNGE

STAFF

RR

MENTAL HEALTH

STORAGE

234A

P. S.

234B

TOILET & LOCKER

SOCIAL

WORKER

SOCIAL

WORKER

SOCIAL

SVC

WAITING

RM

CLINICAL NURSE

SPECIALIST

SOCIAL WORK

ASSOCIATE

SOCIAL SCIENCE

TECHNICIAN

STAFF

OFFICE

MEN

STAFF RR

HAC

BMS

221A

STAFF

PSYCHIATRIST

PSYCHOLOGICAL

RM

GROUP

RM

CORR

STAFF

PSYCHIATRIST

STAFF

PSYCHOLOGIST

REGISTERED

NURSE

SHOWER

RM

213A

UTILITIES

PIPE CHASE

STAFF

WOMEN RR

PIPE

SPACE

TOILET

257A

WOMEN'S

TOILET

STORAGE

WORK RM

W. STAFF T.

STORAGE RM

245A

C7 206.M-401

E7 206.M-401

3/4" CD

CD

TELECOM

ROOM

STORAGE RM

245A

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Fi le

P at h U.S. Department of Veterans Affairs

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

STAMPCONSULTANT

321 4 5 6 7 8 9 10

Project Director

Revisions: Date:

Key Plan

691-20-200FINAL CONSTRUCTION

DOCUMENTS

June 15, 2021 MS TS / JM

FULLY SPRINKLERED

A

GENERAL NOTES

KEY NOTES

ARCHITECT/ENGINEER OF RECORD

D

17075 Via Del Campo, San Diego, CA 92127 Phone: 858.946.0333

11301 WILSHIRE BOULEVARD

WEST LOS ANGELES, CA 90073

20801.12

Electronic Health Records Modernization (EHRM) Infrastructure Upgrades -

WLA, CA

C

B

206.M-121

MECHANICAL SECOND FLOOR PLAN

- BUILDING 206 BUILDING 206

MECHANICAL SECOND FLOOR PLAN - BUILDING 206F1 SCALE:

NORTH

0' 4' 8' 16'SCALE: 1/8" = 1'-0"

1. CONDENSATE DRAIN DISCHARGE TO UTILITY SINK.

SEE DETAIL F5/M-501.

1. RS/RL SIZED PER MANUFACTURER'S RECOMMENDATIONS.

2. REFER TO M-80X FOR PHOTO REFERENCES ( ).

3. ROUTE CONDENSATE DRAIN PIPING CONCEALED ABOVE

CEILING, EXCEPT IN JANITORS CLOSET / HOUSEKEEPING

ROOMS WITH HARD LID CEILINGS. PATCH AND REPAIR

CEILING WHERE REQUIRED TO PENETRATE CEILING.

4. RS/RL ROUTING IS SHOWN FOR REFERENCE.

ALTERNATIVE ROUTING MAY BE USED BASED ON

COORDINATED SHOP DRAWINGS AND IN ACCORDANCE

WITH MANUFACTURER'S REQUIREMENTS.

1D

C1 210.M-401

E1 210.M-401

3/4" CD

(TYP)

(TYP)

(E) MECHANICAL

EQUIPMENT TO REMAIN CU

210-221K

CU

210-122C

CU

210-9

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Fi le

P at h U.S. Department of Veterans Affairs

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

STAMPCONSULTANT

321 4 5 6 7 8 9 10

Project Director

Revisions: Date:

Key Plan

691-20-200FINAL CONSTRUCTION

DOCUMENTS

June 15, 2021 MS TS / JM

FULLY SPRINKLERED

A

GENERAL NOTES

KEY NOTES

ARCHITECT/ENGINEER OF RECORD

D

17075 Via Del Campo, San Diego, CA 92127 Phone: 858.946.0333

11301 WILSHIRE BOULEVARD

WEST LOS ANGELES, CA 90073

20801.12

Electronic Health Records Modernization (EHRM) Infrastructure Upgrades -

WLA, CA

C

B

210.M-101

MECHANICAL BASEMENT FLOOR

PLAN - BUILDING 210 BUILDING 210

MECHANICAL BASEMENT FLOOR PLAN - BUILDING 210F1 SCALE:

NORTH

0' 4' 16' 24'2' 8'SCALE: 3/32" = 1'-0"

1. CONDENSATE DRAIN DISCHARGE INDIRECTLY TO MOP

SINK. ROUTE PIPING EXPOSED IN THE ROOM.

2. PROVIDE CODE REQUIRED AND MANUFACTURER'S

RECOMMENDED EQUIPMENT CLEARANCE.

3. PROVIDE CONCRETE HOUSEKEEPING PAD.

4. RS/RL UP TO FIRST FLOOR. REFER TO 210.M-111.

5. DEMOLISH CONDENSING UNIT, REFRIGERANT PIPES

TO/FROM THE ASSOCIATED INDOOR UNIT, AND ALL

ASSOCIATED APPURTENANCES.

1. RS/RL SIZED PER MANUFACTURER'S RECOMMENDATIONS.

2. REFER TO M-80X FOR PHOTO REFERENCES ( ).

3. ROUTE CONDENSATE DRAIN PIPING CONCEALED ABOVE

CEILING, EXCEPT IN JANITORS CLOSET / HOUSEKEEPING

ROOMS WITH HARD LID CEILINGS. PATCH AND REPAIR

CEILING WHERE REQUIRED TO PENETRATE CEILING.

4. RS/RL ROUTING IS SHOWN FOR REFERENCE.

ALTERNATIVE ROUTING MAY BE USED BASED ON

COORDINATED SHOP DRAWINGS AND IN ACCORDANCE

WITH MANUFACTURER'S REQUIREMENTS.

1E

C4

E4 210.M-401

NEW TELECOM ROOM

3/4" CD

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Fi le

P at h U.S. Department of Veterans Affairs

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

STAMPCONSULTANT

321 4 5 6 7 8 9 10

Project Director

Revisions: Date:

Key Plan

691-20-200FINAL CONSTRUCTION

DOCUMENTS

June 15, 2021 MS TS / JM

FULLY SPRINKLERED

A

GENERAL NOTES

KEY NOTES

ARCHITECT/ENGINEER OF RECORD

D

17075 Via Del Campo, San Diego, CA 92127 Phone: 858.946.0333

11301 WILSHIRE BOULEVARD

WEST LOS ANGELES, CA 90073

20801.12

Electronic Health Records Modernization (EHRM) Infrastructure Upgrades -

WLA, CA

C

B

210.M-111

MECHANICAL FIRST FLOOR PLAN -

BUILDING 210 BUILDING 210

MECHANICAL FIRST FLOOR PLAN - BUILDING 210F1 SCALE:

NORTH

0' 4' 16' 24'2' 8'SCALE: 3/32" = 1'-0"

1. DISCHARGE CONDENSATE DRAIN TO UTILITY SINK. SEE

DETAIL F5/M-501.

2. NOT USED.

3. RS/RL DOWN TO BASEMENT FLOOR. REFER TO 210.M-101

FOR CONTINUATION.

4. RS/RL DOWN TO BASEMENT FLOOR AND UP TO SECOND

FLOOR. REFER TO 210.M-101 AND 210.M-121 FOR

CONTINUATION.

1. RS/RL SIZED PER MANUFACTURER'S RECOMMENDATIONS.

2. REFER TO M-80X FOR PHOTO REFERENCES ( ).

3. ROUTE CONDENSATE DRAIN PIPING CONCEALED ABOVE

CEILING, EXCEPT IN JANITORS CLOSET / HOUSEKEEPING

ROOMS WITH HARD LID CEILINGS. PATCH AND REPAIR

CEILING WHERE REQUIRED TO PENETRATE CEILING.

4. RS/RL ROUTING IS SHOWN FOR REFERENCE.

ALTERNATIVE ROUTING MAY BE USED BASED ON

COORDINATED SHOP DRAWINGS AND IN ACCORDANCE

WITH MANUFACTURER'S REQUIREMENTS.

1. RS/RL SIZED PER MANUFACTURER'S RECOMMENDATIONS.

2. REFER TO M-80X FOR PHOTO REFERENCES ( ).

3. ROUTE CONDENSATE DRAIN PIPING CONCEALED ABOVE

CEILING, EXCEPT IN JANITORS CLOSET / HOUSEKEEPING

ROOMS WITH HARD LID CEILINGS. PATCH AND REPAIR

CEILING WHERE REQUIRED TO PENETRATE CEILING.

4. RS/RL ROUTING IS SHOWN FOR REFERENCE.

ALTERNATIVE ROUTING MAY BE USED BASED ON

COORDINATED SHOP DRAWINGS AND IN ACCORDANCE

WITH MANUFACTURER'S REQUIREMENTS.

1. RS/RL SIZED PER MANUFACTURER'S RECOMMENDATIONS.

2. REFER TO M-80X FOR PHOTO REFERENCES ( ).

3. ROUTE CONDENSATE DRAIN PIPING CONCEALED ABOVE

CEILING, EXCEPT IN JANITORS CLOSET / HOUSEKEEPING

ROOMS WITH HARD LID CEILINGS. PATCH AND REPAIR

CEILING WHERE REQUIRED TO PENETRATE CEILING.

4. RS/RL ROUTING IS SHOWN FOR REFERENCE.

ALTERNATIVE ROUTING MAY BE USED BASED ON

COORDINATED SHOP DRAWINGS AND IN ACCORDANCE

WITH MANUFACTURER'S REQUIREMENTS.

1F

C7

E7 210.M-401

3/4" CD

NEW TELECOM ROOM

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Fi le

P at h U.S. Department of Veterans Affairs

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

STAMPCONSULTANT

321 4 5 6 7 8 9 10

Project Director

Revisions: Date:

Key Plan

691-20-200FINAL CONSTRUCTION

DOCUMENTS

June 15, 2021 MS TS / JM

FULLY SPRINKLERED

A

GENERAL NOTES

KEY NOTES

ARCHITECT/ENGINEER OF RECORD

D

17075 Via Del Campo, San Diego, CA 92127 Phone: 858.946.0333

11301 WILSHIRE BOULEVARD

WEST LOS ANGELES, CA 90073

20801.12

Electronic Health Records Modernization (EHRM) Infrastructure Upgrades -

WLA, CA

C

B

210.M-121

MECHANICAL SECOND FLOOR PLAN

- BUILDING 210 BUILDING 210

MECHANICAL SECOND FLOOR PLAN - BUILDING 210F1 SCALE:

NORTH

0' 4' 16' 24'2' 8'SCALE: 3/32" = 1'-0"

1. DISCHARGE CONDENSATE DRAIN TO UTILITY SINK. SEE

DETAIL F5/M-501.

2. RS/RL DOWN TO BASEMENT AND FIRST FLOOR. REFER TO

210.M-101 AND 210.M-111 FOR CONTINUATION.

1. RS/RL SIZED PER MANUFACTURER'S RECOMMENDATIONS.

2. REFER TO M-80X FOR PHOTO REFERENCES ( ).

3. ROUTE CONDENSATE DRAIN PIPING CONCEALED ABOVE

CEILING, EXCEPT IN JANITORS CLOSET / HOUSEKEEPING

ROOMS WITH HARD LID CEILINGS. PATCH AND REPAIR

CEILING WHERE REQUIRED TO PENETRATE CEILING.

4. RS/RL ROUTING IS SHOWN FOR REFERENCE.

ALTERNATIVE ROUTING MAY BE USED BASED ON

COORDINATED SHOP DRAWINGS AND IN ACCORDANCE

WITH MANUFACTURER'S REQUIREMENTS.

1G

UP

UP

A

B

C

D

E

G

F

1 2 3 4 5 6 7 8 9 11 12 13 14 15 16 17 18 1910

UNISEX

TOILET

B43A

ELECTRICAL

CLOSET

B03

CLOSET

ELEV

MACH

RM

B02

LOCKER

B43

MENS

TOILET

B34

WOMENS

TOILET

B32

ELC

PANEL

B20A

SOILED

INSTRUMENTS

B28

LOCKER

B26B

SUPPLIES

B24A

PATIENT

RESTROOM

B17A

TELELECOM

RM

B09

CORRIDOR

EXAM RM

B41HEMODIALYSIS

B44 B36

EXIT

CORRIDOR

B35

ELC CL

B43B

KITCHEN

B42

DIALYSIS

PREPARATION

B45 TECH SUPPLIES

B46

LOCKER

B47

B48

WATER

TREATMENT

B50

NURSING

SUPPLIES

B51

SUPPLIES

B52B44A

HAC

B37

EMS

SUPPLY

RM

B39

LOCKER

B38

TOILET

B40

ELEVATOR

EQUIP

B08

TRANSFORMER RM

SOLAR PANEL

DISCONNECT

B11

B13

COMMUNITY

NURSING HOME

PGM

B14

STORAGE

B15

B16

DOCTORS OFFICE

B17C

DOCTORS OFFICE

B17D

DOCTORS OFFICE

B17

X RAY RM

B19

EXAM RM

B20

DENTAL LAB

B21

B21A

CLEAN RM

B22

SUPPLIES RM

B22A

BARBER SHOP

B07

STORAGE

B06

LAUNDRY

B05

WASTE COLLECTION

B04

PHARMACY

B33

VAULT

B33B

CLOTHING RM

B01

LOUNGE

B33A

CONFERENCE

RM

B31A

PHARMACY

B31

WAITING

B30

TREATMENT RM

B29

EXAM RM

B25

LOUNGE

B26LOCKER

B26C

TOILET

B26A

TREATMENT RM

B24

ELEVATOR

EAST

STAIR

B49

ELEVATOR

CENTRAL

STAIR

B12

WEST

STAIR

B23

EL 01

EL 02

STORAGE

ELECTRICAL RM

LOBBY

CL 01

HEMODIALYSIS SOILED

UTILITY

SUPPLIES

B36A

LAB

CR 01

C1 213.M-401

E1 213.M-401

3/4" CD

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Fi le

P at h U.S. Department of Veterans Affairs

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

STAMPCONSULTANT

321 4 5 6 7 8 9 10

Project Director

Revisions: Date:

Key Plan

691-20-200FINAL CONSTRUCTION

DOCUMENTS

June 15, 2021 MS TS / JM

FULLY SPRINKLERED

A

GENERAL NOTES

KEY NOTES

ARCHITECT/ENGINEER OF RECORD

D

17075 Via Del Campo, San Diego, CA 92127 Phone: 858.946.0333

11301 WILSHIRE BOULEVARD

WEST LOS ANGELES, CA 90073

20801.12

Electronic Health Records Modernization (EHRM) Infrastructure Upgrades -

WLA, CA

C

B

213.M-101

MECHANICAL BASEMENT FLOOR

PLAN - BUILDING 213 BUILDING 213

MECHANICAL BASEMENT FLOOR PLAN - BUILDING 213F1 SCALE:

NORTH

0' 4' 16' 24'2' 8'SCALE: 3/32" = 1'-0"

1. DISCHARGE CONDENSATE DRAIN TO MOP SINK. SEE

DETAIL C5/M-502.

1. RS/RL SIZED PER MANUFACTURER'S RECOMMENDATIONS.

2. REFER TO M-80X FOR PHOTO REFERENCES ( ).

3. ROUTE CONDENSATE DRAIN PIPING CONCEALED ABOVE

CEILING, EXCEPT IN JANITORS CLOSET / HOUSEKEEPING

ROOMS WITH HARD LID CEILINGS. PATCH AND REPAIR

CEILING WHERE REQUIRED TO PENETRATE CEILING.

4. RS/RL ROUTING IS SHOWN FOR REFERENCE.

ALTERNATIVE ROUTING MAY BE USED BASED ON

COORDINATED SHOP DRAWINGS AND IN ACCORDANCE

WITH MANUFACTURER'S REQUIREMENTS.

1H

DNUP

UP

UP

H/C

TELECOMM

RM 103

BLDG

ENTRY

A

B

C

D

E

G

F

1 2 3 4 5 6 7 8 9 11 12 13 14 15 16 17 18 1910

RESTROOM

120A 110

ELEC

CLO

114A

DINING HALL

ELEVATOR LOBBY

CORRIDOR

MENS

RESTROOM

OCCUPATIONAL THERAPY

CONFERENCE RM

106B

106D

TOILET

106C

TOILET

106A

TOILET

106DIETICIAN

MED

DIRECTORS

SUITE

CHIEF GRC

107A

EAST STAIRWEST STAIR CENTER STAIR

ELEVATOR

SVC

ELEVATOR

WAITING RM

COMPUTER

ASST

TIMEKEEPER

EXERCISE GYM

WOMENS

RESTROOM

SOCIAL WORK

CO-ORDR

104B

104A

COPY RM

107C

CLINICAL

DIRECTOR

107B108

GERIATRIC

NURSE

PRACTITIONER

109B

GERIATRIC

EDUCATIONAL

109A

AUDIO

SPEECH

109ADMIN

OFFICER

112A

112B112C

SWA

SOILED LINEN

OFFICE

FOOD

WARMING RM

SUPPLIES RM (FOR

RECREATION ACTIVITY)

124C

STORAGE

ELC

CL

RECREATION THERAPY

HAC

TRASH

AREA

STORAGE SHOWER

TOILET

PSYCHOLOGIST

101A

EL 02

ST 03 ST02

LOUNGE

CR 04

CORRIDOR

CR 01

OFFICE

OFFICE

OFFICE

ELEC

CL

TOILET

EXERCISE RM

ST01

ELEVATOR

C4 213.M-401

E4 213.M-401

3/4" CD

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Fi le

P at h U.S. Department of Veterans Affairs

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

STAMPCONSULTANT

321 4 5 6 7 8 9 10

Project Director

Revisions: Date:

Key Plan

691-20-200FINAL CONSTRUCTION

DOCUMENTS

June 15, 2021 MS TS / JM

FULLY SPRINKLERED

A

GENERAL NOTES

KEY NOTES

ARCHITECT/ENGINEER OF RECORD

D

17075 Via Del Campo, San Diego, CA 92127 Phone: 858.946.0333

11301 WILSHIRE BOULEVARD

WEST LOS ANGELES, CA 90073

20801.12

Electronic Health Records Modernization (EHRM) Infrastructure Upgrades -

WLA, CA

C

B

213.M-111

MECHANICAL FIRST FLOOR PLAN -

BUILDING 213 BUILDING 213

MECHANICAL FIRST FLOOR PLAN - BUILDING 213F1 SCALE:

NORTH

0' 4' 16' 24'2' 8'SCALE: 3/32" = 1'-0"

1. DISCHARGE CONDENSATE DRAIN TO MOP SINK. SEE

DETAIL C5/M-502.

1. RS/RL SIZED PER MANUFACTURER'S RECOMMENDATIONS.

2. REFER TO M-80X FOR PHOTO REFERENCES ( ).

3. ROUTE CONDENSATE DRAIN PIPING CONCEALED ABOVE

CEILING, EXCEPT IN JANITORS CLOSET / HOUSEKEEPING

ROOMS WITH HARD LID CEILINGS. PATCH AND REPAIR

CEILING WHERE REQUIRED TO PENETRATE CEILING.

4. RS/RL ROUTING IS SHOWN FOR REFERENCE.

ALTERNATIVE ROUTING MAY BE USED BASED ON

COORDINATED SHOP DRAWINGS AND IN ACCORDANCE

WITH MANUFACTURER'S REQUIREMENTS.

1I

DN

UP

UP

UP

1 2 3 4 5 6 7 8 9 11 12 13 14 15 16 17 18 1910

A

B

C

D

E

G

F

TELECOM

RM

CLO

TOILET

OXYGEN

STORAGE

ELECT

CLOSET

ELC

CL

ELC CL

SHOWER BATH

AND TOILET RM

CONGREGATE

BATH AND

TOILET RM

TOILET

CORRIDOR

ELEVATOR

LOBBY

TV LOUNGE/

WAITING AREA

TOILET

TOILET

2-BED

PATIENT RM

TOILET

2 BED

PATIENT RM

2 BED

PATIENT RM

TOILET

2 - BED

PATIENT RM

2 - BED

PATIENT RM

TOILET

2 - BED PATIENT

RM

4 - BED PATIENT RM

TOILET

TOILET

NURSE

STATION

2 - BED

PATIENT RM

NURSE MGR

MEDICATION

RM

SVC

ELEVATOR 224

NOURISHMENT

KITCHEN RM

SOLID LINEN RM

2-BED RM

TOILET

TOILET

DAY RM AND TOILET RM

2 - BED

PATIENT RM

TOILET

TOILET

2 - BED

PATIENT RM

2 - BED

PATIENT RM

2 - BED PATIENT

RM

TOILET

1 - BED

PATIENT RM

TOILET

TOILET

2 - BED

PATIENT RM

EAST STAIR

TOILET

207TOILET

TOILET

4 - BED PATIENT RM

TOILET

ELEVATOR

HAC

250249

WARD

SUPPLY

RM

LINEN

SUPPLY RM

CENTER STAIR

2 - BED PATIENT RM

TOILET

TOILET

4 - BED PATIENT RM

2 - BED PATIENT

RM

TOILET

COPY RM

2 - BED

PATIENT RM

TOILET

2 - BED

PATIENT RM

WEST STAIR

2 BED PATIENT RM

ST 03

240A

244A 246A

245A

ST 01

TREATMENT RM NURSE MGR

STAFF

RESTROOM

2 BED

PATIENT RM

TOILET

AND

SHOWER

202A 2 - BED

PATIENT RM

204A

206A

2 - BED PATIENT

RM

2 - BED PATIENT

RM

ST 02

209A

210A211A

213A

2 - BED PATIENT

RM

214A

217A

218A

PIPE CHASE

NURSE LOUNGE

EL 02

LAUNDRY RM

PIPE CHASE

230A

231A

234A

235A

237A238A

239A

CL 01

CORRIDOR

CR 02

CR 01

242A

203A

ELEVATOR

207A

C7 213.M-401

E7 213.M-401

3/4" CD

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Fi le

P at h U.S. Department of Veterans Affairs

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

STAMPCONSULTANT

321 4 5 6 7 8 9 10

Project Director

Revisions: Date:

Key Plan

691-20-200FINAL CONSTRUCTION

DOCUMENTS

June 15, 2021 MS TS / JM

FULLY SPRINKLERED

A

GENERAL NOTES

KEY NOTES

ARCHITECT/ENGINEER OF RECORD

D

17075 Via Del Campo, San Diego, CA 92127 Phone: 858.946.0333

11301 WILSHIRE BOULEVARD

WEST LOS ANGELES, CA 90073

20801.12

Electronic Health Records Modernization (EHRM) Infrastructure Upgrades -

WLA, CA

C

B

213.M-121

MECHANICAL SECOND FLOOR PLAN

- BUILDING 213 BUILDING 213

MECHANICAL SECOND FLOOR PLAN - BUILDING 213F1 SCALE:

NORTH

0' 4' 16' 24'2' 8'SCALE: 3/32" = 1'-0"

1. DISCHARGE CONDENSATE DRAIN TO MOP SINK. SEE

DETAIL C5/M-502.

2. ROUTE CONDENSATE EXPOSED BELOW CEILING. PATCH

AND REPAIR CEILING AS REQUIRED.

1J

DN

1 2 3 4 5 6 7 8 9 11 12 13 14 15 16 17 18 1910

A

B

C

D

E

G

F

TELECOM

RM

HBPC OFFICE

TOILET &

SHOWER

TOILET

TOILET

ELC

ELC

COPY RM

ELC

CL

CLCL

CORRIDORCORRIDOR

WAITING AREA

CORRIDOR

TOILET

TOILET

OFFICE

TOILET

OFFICE

TELECARE

OFFICE

TOILET

TELECARE

OFFICE

TELECARE

OFFICE

334 TOILET

OFFICE

OFFICE

TOILET

OFFICE

NURSE STATION

328 327

ELEVATOR

WOUND CARE

PGM MGR

HPBC OFFICE

TOILET

TOILET

HBPC OFFICE

HBPC OFFICE

TOILET

HBPC OFFICE

HBPC OFFICE

TOILET

HBPC OFFICE

HBPC OFFICE

TOILET

HBPC OFFICE

TOILET

TOILET

EAST STAIR

TOILET

307306TOILET

TOILET

TOILET

HBPC OFFICE

TOILET

OFFICE

ELEVATOR

TOILET 351

350349

SUPPLY

348OFFICE

CENTRAL STAIR

CONFERENCE RM

TOILET

TOILET

OFFICE

OFFICE TELE

HEALTH

COPY

TOILET

STORAGE

OFFICE

TOILET

OFFICE

WEST STAIR

PROGRAM MGR

HBPC OFFICE

ST 03

340A

342A

344A 346A

345A

ST 01

OFFICE OFFICE

HAC

302A

303A

304A

306A

HBPC OFFICE HBPC OFFICE

ST 02

309A

310A311A

312A 314A

317A

318A

NOURISHMENT

KITCHEN

HMPC

SUPPLY/STORAGE

EL 02

STAFF OFFICE

STAFF OFFICE

SUPPLIES

STORAGE

330A

331A

332A

335A

337A 338A

339A

CR 01

ELEVATOR

STORAGE

307A

C1 213.M-402

E1 213.M-402

3/4" CD

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Fi le

P at h U.S. Department of Veterans Affairs

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

STAMPCONSULTANT

321 4 5 6 7 8 9 10

Project Director

Revisions: Date:

Key Plan

691-20-200FINAL CONSTRUCTION

DOCUMENTS

June 15, 2021 MS TS / JM

FULLY SPRINKLERED

A

GENERAL NOTES

KEY NOTES

ARCHITECT/ENGINEER OF RECORD

D

17075 Via Del Campo, San Diego, CA 92127 Phone: 858.946.0333

11301 WILSHIRE BOULEVARD

WEST LOS ANGELES, CA 90073

20801.12

Electronic Health Records Modernization (EHRM) Infrastructure Upgrades -

WLA, CA

C

B

213.M-131

MECHANICAL THIRD FLOOR PLAN -

BUILDING 213 BUILDING 213

MECHANICAL THIRD FLOOR PLAN - BUILDING 213F1 SCALE:

NORTH

0' 4' 16' 24'2' 8'SCALE: 3/32" = 1'-0"

1. DISCHARGE CONDENSATE DRAIN TO MOP SINK. SEE

DETAIL C5/M-502.

1. RS/RL SIZED PER MANUFACTURER'S RECOMMENDATIONS.

2. REFER TO M-80X FOR PHOTO REFERENCES ( ).

3. ROUTE CONDENSATE DRAIN PIPING CONCEALED ABOVE

CEILING, EXCEPT IN JANITORS CLOSET / HOUSEKEEPING

ROOMS WITH HARD LID CEILINGS. PATCH AND REPAIR

CEILING WHERE REQUIRED TO PENETRATE CEILING.

4. RS/RL ROUTING IS SHOWN FOR REFERENCE.

ALTERNATIVE ROUTING MAY BE USED BASED ON

COORDINATED SHOP DRAWINGS AND IN ACCORDANCE

WITH MANUFACTURER'S REQUIREMENTS.

1K

1 2 3 4 5 6 7 8 9 11 12 13 14 15 16 17 18 1910

A

B

C

D

E

G

F

CU

213-B-9

CU

213-301

CU

213-103

CU

213-201

2 1

(TYP)

(TYP)

(TYP)

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Fi le

P at h U.S. Department of Veterans Affairs

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

STAMPCONSULTANT

321 4 5 6 7 8 9 10

Project Director

Revisions: Date:

Key Plan

691-20-200FINAL CONSTRUCTION

DOCUMENTS

June 15, 2021 MS TS / JM

FULLY SPRINKLERED

A

GENERAL NOTES

KEY NOTES

ARCHITECT/ENGINEER OF RECORD

D

17075 Via Del Campo, San Diego, CA 92127 Phone: 858.946.0333

11301 WILSHIRE BOULEVARD

WEST LOS ANGELES, CA 90073

20801.12

Electronic Health Records Modernization (EHRM) Infrastructure Upgrades -

WLA, CA

C

B

213.M-1R1

MECHANICAL ROOF PLAN -

BUILDING 213 BUILDING 213

MECHANICAL ROOF PLAN - BUILDING 213F1 SCALE:

NORTH

0' 4' 16' 24'2' 8'SCALE: 3/32" = 1'-0"

1. PROVIDE CODE REQUIRED AND MANUFACTURER'S

RECOMMENDED EQUIPMENT CLEARANCE.

2. RS/RL DOWN TO FLOORS BELOW. REFER TO 213.M-401

AND 213.M-402 FOR CONTINUATION.

3. PROVIDE CONCRETE HOUSEKEEPING PAD.

1. RS/RL SIZED PER MANUFACTURER'S RECOMMENDATIONS.

2. REFER TO M-80X FOR PHOTO REFERENCES ( ).

3. ROUTE CONDENSATE DRAIN PIPING CONCEALED ABOVE

CEILING, EXCEPT IN JANITORS CLOSET / HOUSEKEEPING

ROOMS WITH HARD LID CEILINGS. PATCH AND REPAIR

CEILING WHERE REQUIRED TO PENETRATE CEILING.

4. RS/RL ROUTING IS SHOWN FOR REFERENCE.

ALTERNATIVE ROUTING MAY BE USED BASED ON

COORDINATED SHOP DRAWINGS AND IN ACCORDANCE

WITH MANUFACTURER'S REQUIREMENTS.

EX

214.M-401

E1 214.M-401

3/4" CD

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Fi le

P at h U.S. Department of Veterans Affairs

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

STAMPCONSULTANT

321 4 5 6 7 8 9 10

Project Director

Revisions: Date:

Key Plan

691-20-200FINAL CONSTRUCTION

DOCUMENTS

June 15, 2021 MS TS / JM

FULLY SPRINKLERED

A

GENERAL NOTES

KEY NOTES

ARCHITECT/ENGINEER OF RECORD

D

17075 Via Del Campo, San Diego, CA 92127 Phone: 858.946.0333

11301 WILSHIRE BOULEVARD

WEST LOS ANGELES, CA 90073

20801.12

Electronic Health Records Modernization (EHRM) Infrastructure Upgrades -

WLA, CA

C

B

214.M-111

MECHANICAL FIRST FLOOR PLAN -

BUILDING 214 BUILDING 214

MECHANICAL FIRST FLOOR PLAN - BUILDING 214F1 SCALE:

NORTH

0' 4' 16' 24'2' 8'SCALE: 3/32" = 1'-0"

1. DISCHARGE CONDENSATE DRAIN TO MOP SINK. SEE

DETAIL C5/M-502.

1. RS/RL SIZED PER MANUFACTURER'S RECOMMENDATIONS.

2. REFER TO M-80X FOR PHOTO REFERENCES ( ).

3. ROUTE CONDENSATE DRAIN PIPING CONCEALED ABOVE

CEILING, EXCEPT IN JANITORS CLOSET / HOUSEKEEPING

ROOMS WITH HARD LID CEILINGS. PATCH AND REPAIR

CEILING WHERE REQUIRED TO PENETRATE CEILING.

4. RS/RL ROUTING IS SHOWN FOR REFERENCE.

ALTERNATIVE ROUTING MAY BE USED BASED ON

COORDINATED SHOP DRAWINGS AND IN ACCORDANCE

HZ

HZ

C4 214.M-401

E4 214.M-401

3/4" CD

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Fi le

P at h U.S. Department of Veterans Affairs

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

STAMPCONSULTANT

321 4 5 6 7 8 9 10

Project Director

Revisions: Date:

Key Plan

691-20-200FINAL CONSTRUCTION

DOCUMENTS

June 15, 2021 MS TS / JM

FULLY SPRINKLERED

A

GENERAL NOTES

KEY NOTES

ARCHITECT/ENGINEER OF RECORD

D

17075 Via Del Campo, San Diego, CA 92127 Phone: 858.946.0333

11301 WILSHIRE BOULEVARD

WEST LOS ANGELES, CA 90073

20801.12

Electronic Health Records Modernization (EHRM) Infrastructure Upgrades -

WLA, CA

C

B

214.M-121

MECHANICAL SECOND FLOOR PLAN

- BUILDING 214 BUILDING 214

MECHANICAL SECOND FLOOR PLAN - BUILDING 214F1 SCALE:

NORTH

0' 4' 16' 24'2' 8'SCALE: 3/32" = 1'-0"

1. CONDENSATE DRAIN TO LAVATORY TAILPIECE, SEE

DETAIL. SEE DETAIL F8/M-501.

1. RS/RL SIZED PER MANUFACTURER'S RECOMMENDATIONS.

2. REFER TO M-80X FOR PHOTO REFERENCES ( ).

3. ROUTE CONDENSATE DRAIN PIPING CONCEALED ABOVE

CEILING, EXCEPT IN JANITORS CLOSET / HOUSEKEEPING

ROOMS WITH HARD LID CEILINGS. PATCH AND REPAIR

CEILING WHERE REQUIRED TO PENETRATE CEILING.

4. RS/RL ROUTING IS SHOWN FOR REFERENCE.

ALTERNATIVE ROUTING MAY BE USED BASED ON

COORDINATED SHOP DRAWINGS AND IN ACCORDANCE

WITH MANUFACTURER'S REQUIREMENTS.

1L

HZ

C7

214.M-401

E7 214.M-401

3/4" CD

2 (TYP)

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Fi le

P at h U.S. Department of Veterans Affairs

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

STAMPCONSULTANT

321 4 5 6 7 8 9 10

Project Director

Revisions: Date:

Key Plan

691-20-200FINAL CONSTRUCTION

DOCUMENTS

June 15, 2021 MS TS / JM

FULLY SPRINKLERED

A

GENERAL NOTES

KEY NOTES

ARCHITECT/ENGINEER OF RECORD

D

17075 Via Del Campo, San Diego, CA 92127 Phone: 858.946.0333

11301 WILSHIRE BOULEVARD

WEST LOS ANGELES, CA 90073

20801.12

Electronic Health Records Modernization (EHRM) Infrastructure Upgrades -

WLA, CA

C

B

214.M-131

MECHANICAL THIRD FLOOR PLAN -

BUILDING 214 BUILDING 214

MECHANICAL THIRD FLOOR PLAN - BUILDING 214F1 SCALE:

NORTH

0' 4' 16' 24'2' 8'SCALE: 3/32" = 1'-0"

1. CONDENSATE DRAIN TO LAVATORY TAILPIECE, SEE

DETAIL F8/M-501.

2. RS/RL UP TO FLOOR BELOW. REFER TO 214.M-1R1

FOR CONTINUATION.

1. RS/RL SIZED PER MANUFACTURER'S RECOMMENDATIONS.

2. REFER TO M-80X FOR PHOTO REFERENCES ( ).

3. ROUTE CONDENSATE DRAIN PIPING CONCEALED ABOVE

CEILING, EXCEPT IN JANITORS CLOSET / HOUSEKEEPING

ROOMS WITH HARD LID CEILINGS. PATCH AND REPAIR

CEILING WHERE REQUIRED TO PENETRATE CEILING.

4. RS/RL ROUTING IS SHOWN FOR REFERENCE.

ALTERNATIVE ROUTING MAY BE USED BASED ON

COORDINATED SHOP DRAWINGS AND IN ACCORDANCE

CU

214-1

CU

214-205

CU

214-306

(TYP)

(TYP)

2(TYP)

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Fi le

P at h U.S. Department of Veterans Affairs

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

STAMPCONSULTANT

321 4 5 6 7 8 9 10

Project Director

Revisions: Date:

Key Plan

691-20-200FINAL CONSTRUCTION

DOCUMENTS

June 15, 2021 MS TS / JM

FULLY SPRINKLERED

A

GENERAL NOTES

KEY NOTES

ARCHITECT/ENGINEER OF RECORD

D

17075 Via Del Campo, San Diego, CA 92127 Phone: 858.946.0333

11301 WILSHIRE BOULEVARD

WEST LOS ANGELES, CA 90073

20801.12

Electronic Health Records Modernization (EHRM) Infrastructure Upgrades -

WLA, CA

C

B

214.M-1R1

MECHANICAL ROOF PLAN -

BUILDING 214 BUILDING 214

MECHANICAL ROOF PLAN - BUILDING 214F1 SCALE:

NORTH

0' 4' 16' 24'2' 8'SCALE: 3/32" = 1'-0"

1. PROVIDE CODE REQUIRED AND MANUFACTURER'S

RECOMMENDED EQUIPMENT CLEARANCE.

2. RS/RL DOWN TO FLOORS BELOW. REFER TO 214.M-103

FOR CONTINUATION.

3. PROVIDE CONCRETE…