Attachment A2_Drawing 2 of 9.pdf
PDF 28 MB Posted
- Attached to
- Z2DA--EHRM Long Beach, 600-20-120, Construction Federal contract opportunity
- Solicitation number
- 36C26221B0004
About this file
This document provides a presolicitation notice for a construction project at the VA Long Beach Healthcare System. The VA will issue an Invitation for Bid on or about April 12, 2021 via beta.SAM.gov for Project 600-20-120 to perform Electronic Health Record Modernization Infrastructure Upgrades at the VA Long Beach Healthcare System located in Long Beach, CA. Work includes general construction, alterations, mechanical and electrical work, utility systems, necessary demolition and removal of existing structures. The project is set aside 100% for Service-Disabled Veteran-Owned Small Businesses and must be listed as verified in Vendor Information Pages. The North American Industry Classification Code is 236220 for Commercial and Institutional Building Construction with a size standard of $39.5 million. The magnitude of the construction project is estimated between $10 million and $20 million. A site visit will be scheduled for prospective bidders.
View the file
Other files for this federal contract opportunity
Show all 23
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
RAMP DN @ 8%
JANITOR'S
CLOSET (HAC)
2N114
SLEEP
TOILET
2N112A
SLEEP
TOILET
2N110A
TOILET, STAFF
2N101
TOILET,
UNISEX
2N105
SLEEP TOILET
2N118A
SLEEP TOILET
2N116A
ALCOVE,
CRASH CART
2N111
SLEEP TOILET
-BARIATRIC
2N121A
STORAGE
ALCOVE,
WHEELCHAIR
2S138
ALCOVE,
CRASH CART
2S128
STORAGE/
MEDICAL
EQUIP
2S118
ELECRICAL RM
2S119
CLEAN LINEN
2S122
2S121
CLEAN LINEN
SLEEP HALL
2N120
SLEEP
STUDY RM
2N112
SLEEP
STUDY RM
2N110
UTILITY RM,
CLEAN
2N109
TELECOM/
DATA RM
2N107
EXAM/PA
OFFICE
2N104
CORRIDOR NORTH
2N100
COPY
RM
2N103
PATIENT
PREP RM
2N122
COORDINATOR
OFFICE
2N124
STORAGE
EQUIP
2N120
SLEEP
STUDY RM
2N118
SLEEP
STUDY RM
2N116
SLEEP
STUDY RM
2N113
SLEEP HALL
2N120
MONITORING RM
ELECTRICAL
2N119
2N117
SLEEP
TOILET
2N113A
SLEEP STUDY RM
-BARIATRIC
2N121
WHEELCHAIR
STORAGE
2N123
RECEPTION
2N125
CONFERENCE RM
2N126
CORRIDOR
SOUTH
2S106
FAMILY
TOILET
2S104
FAMILY
TOILET
2S103
EYEGLASS
REPAIR
2S105
2S105A
PATIENT
EDUCATION/
DISPENSING
WAITING
RM
2S101
PATIENT KIOSK
2S101A
SLEEP LAB WAITING
2S101B
ELEVATOR
LOBBY
2S100
JANITOR'S
CLOSET
(HAC)
2S102
2S149
STAFF
LOCKER
RM
CONFERENCE
RM/
MULTIPURPOSE
2S153
SUPERVISOR
2S154
TOILET,
STAFF
2S150
NURSE
MGR
2S151
WORK
STATIONS
2S155
STAFF HALL
2S152
SECRETARYS
OFFICE
2S159
OPTOMETRY
CHIEF
2S156
ADMIN
OFFICE
2S157
2S158
OPHTHALMOLOGY
CHIEF
EXAM/TREATMENT
OPHTHALMOLOGY
2S135
EXAM/TREATMENT
OPHTHALMOLOGY
2S137
EXAM/TREATMENT
OPHTHALMOLOGY
2S139
EXAM/TREATMENT
OPHTHALMOLOGY
EXAM/TREATMENT
OPHTHALMOLOGY
2S141
2S143
OPHTHALMOLOGY
EXAM
RM/SPECULAR
2S145
OPHTHALMOLOGY
EXAM
RM/AXL
2S147
RECEPTION
2S123
PRE-
TESTING RM
2S125
VISUAL
FIELDS RM
2S134
PRE-
TESTING
RM
2S136 PRE-
TESTING RM
2S127
OPTICAL
COHERENCE
TOMOGRAPHY/
PHOTOGRAPHY
2S142
PRE-
TESTING RM
2S130
SOILED
UTILITY RM
2S131
CLEAN
SUPPLY RM
2S132
LASER
RM
2S144
OFFICE,
EYECARE
PROVIDER
(TEAMLET)
2S146TOILET,
UNISEX
2S148
OPTICAL
COHERENCE
TOMOGRAPHY/
PHOTOGRAPHY
2S116
EXAM/TRAINING RM,
LOW VISION
2S113
EYE
PROCEDURE
RM
2S133
OFFICE, EYECARE
PROVIDER
(TEAMLET)
2S120
PRE-
TESTING
RM
2S111
PRE-
TESTING
RM
2S126
RECEPTION
2S124
VISUAL
FIELDS
RM
2S109
EXAM/TREATMENT
RM,
OPTOMETRY
2S108
EXAM/TREATMENT
RM,
OPTOMETRY
2S110
EXAM/TREATMENT
RM,
OPTOMETRY
2S112
EXAM/TREATMENT
RM,
OPTOMETRY
2S114
EXAM/TRAINING
RM, LOW
VISION
2S117
SECURITY
CLOSET
2S115
EXAM/TRAINING
RM, LOW
VISION
2S119
ELEVATOR
P-6
STAIR
NO 5
ELEVATOR
P-5
SOILED
UTILITY RM
2N108
NURSE
MGR
2N106
EY
E
CL
IN
IC
H
AL
L
2S
STRUCTURED COPPER CABLING HAS BEEN
UPGRADED TO CAT6 AS PART OF 600-402
(SEISMIC UPGRADE PROJECT). BOUNDED AREA
IS NOT IN SCOPE, EXCEPT AS NOTED:
PATHWAYS FOR BUILDING 7 FROM TR(S) THIS
FLOOR.
VA COORDINATION SECOND
FLOOR REFERENCE PLAN
VA COORDINATION SECOND FLOOR REFERENCE PLAN
REF-09
NORTH
126A(OP)
BUILDING 126A(OP)
F1
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Fi le
P at h
U.S. Department of Veterans Affairs
B
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
321 4 5 6 7 8 9 10
Project Director
Key Plan
Electronic Health Records Modernization (EHRM) Infrastructure Upgrades - Long Beach
5901 E. SEVENTH STREET, LONG BEACH, CA 90822
600-20-120
CONTRACT DOCUMENTS
December 16, 2020 JC GB
FULLY SPRINKLERED
NORTH
A
GENERAL NOTES
0' 4' 16' 24'2' 8'0' 8' 16' 32'0' 4' 8' 16'
C
D
1. THE INFORMATION SHOWN HERE IS PROVIDED BY THE VA.
THE SCOPE AND COORDINATION REQUIREMENTS SHOWN
ON THIS SHEET APPLY TO ALL WORK ON THIS PROJECT.
SCALE: 3/32" = 1'-0"
ELEVATOR
MACHINE RM
B-031A
MECH RM
STORAGE
NOURISH
B-028
CART WASHER
AREA
CO
RR
ID
OR
CC
-B
-1
CORRIDOR
CC-B-5
CO
NN
EC
TI
ON
CO
RR
ID
OR
CC
-B -6
CO
RR
ID
OR
CC
-B
-1
ENTRANCE
MED MEDIA
ENTRANCE
MAIL RM
BOILER
CHAMBER
STORAGE
TRASH
COMPACTOR
AREA
TRASH
COMPACTOR WELL
LAB STORAGE
B-037
ELEVATOR
S-10
ELEVATOR
S-9
EMS
SUPV
OFFICE
EMS SUPV
OFFICE
B-034
PHARMACY
STORAGE
B-015
STORAGE
B-016
GENERAL
STORAGE
B-017
B-019B
CHIEFS OFFICE
B-019A
B-019
TELE CLOSET
STAIR
CORRIDOR
C-B-9
ELEVATOR
P-7
ELEVATOR
P-8
WORK SPACE
B-22B
SEC/RECEPT
B-029
PASSENGER
ELEVATOR LOBBY
PHOTO STUDIO
B-021
FINISHING
RM
B-22D
STORAGE
B-22A
COMPUTER
RM
B-22C
OFFICE
B-22E
CLASS RM
B-22F
CO
RR
ID
OR
C- B-
8 CLASS RM
B-23
CONTROL RM
B-23A
GENERAL
STORAGE
B-24
MED/GRAPHICS DESIGN
OFFICE
B-25
GRAPHIC
ARTIST
B-26
EQUIP
CHECKOUT
B-027
MI
CR
OS
CO
PE
RM
B-
7BCHIEF
B-029A
HAC
STORAGE
B-031
GENERAL
STORAGE
B-013
GENERAL
STORAGE
B-012
ENV CARE
SUPV
OFFICE
B-011
RE
CO
RD
MG
MT
OF
FI
CE
B-
9C
BOILER RM
B-014
CO
RR
ID
OR
CC
-B
-1
4 SUPPLY RM
35B
35A
STORAGE
SUPPLY AND
EQUIPMENT
ISSUE
MAIL RM
HAC STORAGE
ELECTRICAL
PANEL
SVC RM ELEVATOR
LOBBY
VE
RY
D
AR
K
RM
B-
7A
B-014A
B-014B
CENTER
EX
EX
EX
EX
EX
EX
EXEX
001.B.01
001.B.02
001.B.03
001.B.04
001.B.05
001.B.06
HZ
HZ
HZ
HZ
HZ
HZ
HZ
HZ
HZ
HZ
HZ
HZ
1 (TYP)
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Fi le
P at h
U.S. Department of Veterans Affairs
B
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
STAMPCONSULTANT
321 4 5 6 7 8 9 10
Project Director
Revisions: Date:
Key Plan
Electronic Health Records Modernization (EHRM) Infrastructure Upgrades - Long Beach
5901 E. SEVENTH STREET, LONG BEACH, CA 90822
600-20-120
CONTRACT DOCUMENTS
December 16, 2020 JC GB
FULLY SPRINKLERED
NORTH
A
GENERAL NOTES
KEY NOTES
17075 Via Del Campo, San Diego, CA 92127 Phone: 858.946.0333
ARCHITECT/ENGINEER OF RECORD
SCALE: 1/8" = 1'-0" 0' 4' 8' 16'
C
D
20801.10
ARCHITECTURAL BASEMENT
FLOOR PLAN
ARCHITECTURAL BASEMENT FLOOR PLAN
1.A-101
NORTH
BUILDING 1
DOOR RATING LEGEND
NON-RATED SMOKE- RESISTANT
FIRE DOOR
20-MINUTE RATED FIRE DOOR
45-MINUTE RATED FIRE DOOR
60-MINUTE RATED FIRE DOOR
90-MINUTE RATED FIRE DOOR
90-MINUTE SMOKE- RESISTANT
FIRE DOOR
180-MINUTE RATED FIRE DOOR
RATED DOOR TAG
(XX:BLDG; YY: LEVEL; Z:ID; W:MINUTES)
EX
EXIT STAIR
HAZARDOUS ROOM (NFPA 101 §8.7)
INTERIOR EXIT LOCATION
EXTERIOR EXIT DISCHARGE
WALL TYPE LEGEND
HZ
3-HR. FIRE BARRIER
2-HR. FIRE/SMOKE BARRIER
1-HR. FIRE/SMOKE BARRIER
SMOKE BARRIER
SMOKE PARTITION
INTERIOR EXIT PASSAGEWAY
LIFE SAFETY LEGEND
1. REMOVE AND REINSTALL CEILING AS REQUIRED FOR
RUNNING CABLING.
F1
1. PROVIDE UL LISTED FIRESTOPPING AT ALL
PENETRATIONS OF FIRE RATED WALLS.
2. USE EZ PATH OR SIMILAR TO ALLOW CABLES TO
PENETRATE WALLS, W/O LIMITING ABILITY TO
ADD/REMOVE CABLES AT A LATER TIME W/O RESEALING.
3. COORDINATE RELOCATION OF EXISTING EQUIPMENT
AND FURNITURE WITH THE VA AS INDICATED ON
PROJECT NOTE 5 ON GI001.
4. BUILDING 1 CONTAINS HAZARDOUS MATERIALS, REFER
TO GI003.
INFECTION CONTROL
NOTES
1. ON THIS PLAN, ALL CORRIDORS ARE CONSTRUCTION
TYPE D, LOW RISK GROUP AND INFECTION CONTROL
CLASS III. WHERE CORRIDOR IS SHOWN WITHIN AREA OF
HIGHER PRECAUTION CLASS, CORRIDOR SHALL MEET
THE MORE STRINGENT REQUIREMENT.
2. ALL OTHER AREAS ON THIS PLAN SHALL BE CONSIDERED
CONSTRUCTION TYPE C, LOW RISK GROUP AND
INFECTION CONTROL PRECAUTION CLASS II UNLESS
OTHERWISE NOTED.
3. REFER TO SHEET GI004 THRU GI007 FOR ASSOCIATED
REQUIREMENTS.
STAFF
WOMEN
112A
MECH
SHAFT
DOC
CONN
CORRIDOR
MC-C6
S101A
STAIR
CORRIDOR
C-1-2
CORRIDOR
C-1-4
CORRIDOR
C-1-5
CORRIDOR
C-1-6
CORRIDOR
C-1-1
W
AI
TI
NG
A
RE
A
MEN REST
RM
N104
HAC
N103
MECH
SHAFT
TELEPHONE
CLOSET
IT
STORAGE
N166
SVC ELEVATOR
LOBBY
ELEVATOR
S-9
ELEVATOR
S-10
NURSE CASE
MGR
S116
NURSE CASE
MGR
116A
NURSE
S117
STAFF LOUNGE
GROUP RM
PSYCH
RN CARE
CO-ORDR OFFICE
118A
MEDICATION
RM
DOC OFFICE
S120
WAITING AREA
S123
NURSE
PSYCH
S122
PSYCH
OFFICE
S124
TELECOM
STAIR
CORRIDOR
C-1-3
ELEVATOR
P-8
ELEVATOR
P-7
PASSENGER
ELEVATOR
ELOBBY
RN CARE
CO-ORDR
S101L
CONFERENCE
RM
S101M
OFFICE
S101K
CASE MGR
OFFICE
S101J
EXAM/
TREATMENT RM
S102G S
PATHOLOGIST
TRAINEE
S102F
STAIR
SPEECH
PATHOLOGIST
OFFICE
S102D
WAITING
S102C
CHIEF
SPEECH
PATHOLOGY
S102B
SPEECH
PATHOLOGIST
S102A
STAFF
PSYCHIATRIST
S101H
OFFICE
S101G
OFFICE
S101F
DOCTORS OFFICE
S101E
NURSE
CASE MGR
OFFICE
S101D
WAITING
AREA
S101
DIABETIC
S101C
ADMIN
NURSE
OFFICE
S101B
HAC
SOCIAL
WORKER
COUPLES
OFFICE
S105
OF
FI
CE
S1
-1EXAM RM
S106
NURSE
PRACTITIONER
S107
STAFF
PSYCHATRIST
S108
STAFF
PSYCHIATRISTS
EXAM RM
S109
OFFICE
S110
HAC
SOCIAL
WORKER
OFFICE
S114
OFFICE
S114A
PRIMARY CARE
NURSE
PRACTITIONER
S113
STAFF
MEN
NO 3
NO 2
FE
SOUND
BOOTH
CLASS RM
FAC
PEER
SUPPORT
OFFICE
S102E
IT
STORAGE
N166B
S123A
CENTERFEC
CORRIDOR
EMS SVC
N166A
C1-3A
SOLARIUM
CORRIDOR
C-1-7
EX
EX
HZ
HZ
HZ
HZHZ
EX
EX
TELECOM ROOM
E1 A-402
B1 A-402
1 (TYP)
RISK: MEDIUM
INFECTION CONTROL PRECAUTION: CLASS III
RISK: HIGH
INFECTION CONTROL PRECAUTION: CLASS III
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Fi le
P at h
U.S. Department of Veterans Affairs
B
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
STAMPCONSULTANT
321 4 5 6 7 8 9 10
Project Director
Revisions: Date:
Key Plan
Electronic Health Records Modernization (EHRM) Infrastructure Upgrades - Long Beach
5901 E. SEVENTH STREET, LONG BEACH, CA 90822
600-20-120
CONTRACT DOCUMENTS
December 16, 2020 JC GB
FULLY SPRINKLERED
NORTH
A
GENERAL NOTES
KEY NOTES
17075 Via Del Campo, San Diego, CA 92127 Phone: 858.946.0333
ARCHITECT/ENGINEER OF RECORD
SCALE: 1/8" = 1'-0" 0' 4' 8' 16'
C
D
20801.10
ARCHITECTURAL FIRST FLOOR
PLAN
ARCHITECTURAL FIRST FLOOR PLAN
1.A-111
NORTH
BUILDING 1
1. REMOVE AND REINSTALL CEILING AS REQUIRED FOR
RUNNING CABLING.
F1
DOOR RATING LEGEND
NON-RATED SMOKE- RESISTANT
FIRE DOOR
20-MINUTE RATED FIRE DOOR
45-MINUTE RATED FIRE DOOR
60-MINUTE RATED FIRE DOOR
90-MINUTE RATED FIRE DOOR
90-MINUTE SMOKE- RESISTANT
FIRE DOOR
180-MINUTE RATED FIRE DOOR
RATED DOOR TAG
(XX:BLDG; YY: LEVEL; Z:ID; W:MINUTES)
EX
EXIT STAIR
HAZARDOUS ROOM (NFPA 101 §8.7)
INTERIOR EXIT LOCATION
EXTERIOR EXIT DISCHARGE
WALL TYPE LEGEND
HZ
3-HR. FIRE BARRIER
2-HR. FIRE/SMOKE BARRIER
1-HR. FIRE/SMOKE BARRIER
SMOKE BARRIER
SMOKE PARTITION
INTERIOR EXIT PASSAGEWAY
LIFE SAFETY LEGEND
1. PROVIDE UL LISTED FIRESTOPPING AT ALL
PENETRATIONS OF FIRE RATED WALLS.
2. USE EZ PATH OR SIMILAR TO ALLOW CABLES TO
PENETRATE WALLS, W/O LIMITING ABILITY TO
ADD/REMOVE CABLES AT A LATER TIME W/O RESEALING.
3. COORDINATE RELOCATION OF EXISTING EQUIPMENT
AND FURNITURE WITH THE VA AS INDICATED ON
PROJECT NOTE 5 ON GI001.
4. BUILDING 1 CONTAINS HAZARDOUS MATERIALS, REFER
TO GI003.
INFECTION CONTROL
NOTES
1. ON THIS PLAN, ALL CORRIDORS ARE CONSTRUCTION
TYPE D, LOW RISK GROUP AND INFECTION CONTROL
CLASS III. WHERE CORRIDOR IS SHOWN WITHIN AREA OF
HIGHER PRECAUTION CLASS, CORRIDOR SHALL MEET
THE MORE STRINGENT REQUIREMENT.
2. ALL OTHER AREAS ON THIS PLAN SHALL BE CONSIDERED
CONSTRUCTION TYPE C, LOW RISK GROUP AND
INFECTION CONTROL PRECAUTION CLASS II UNLESS
OTHERWISE NOTED.
FEC
PH
AR
MA
CY
VE
ND
OR
CLOSET
200X
EP
200J
ST
OR
AG
E
0W
0V
CORRIDOR
C2-5
CO
RR
ID
OR
C2 -4
VISUAL INFO
SPECIALIST
OFFICE
CORRIDOR
C2-3
STUDENT
CO-ORDR OFFICE
NURSE
OFFICE
INPATIENT
CLINICAL
PHARMACY
RESIDENT
218B
INPATIENT
CLINICAL SUP
RESIDENCY
PROG DIR
218A
STERILE
PROCESSING
ELEVATOR
S-10
ELEVATOR
S-9
MECH
SHAFT
CO
RR
ID
OR
STORAGE
232A
HAC
GENERAL
STORAGE
PHARMACY
AND CLINICAL
SUPPORT
SVCS
BUSINESS
MGR OFFICE
ADMIN ASST
OFFICE
PRAYER AND
MEDITATION RM
NUTRITION
OFFICE
225A
MEN TOILET
FAC
INFORMATICS
PHARMACIST
WOMEN
TIOLET
HAC
CLOSET
CORRIDOR
C2-1
PASSENGER
ELEVATOR
LOBBY
EL
EV
AT
OR
P-
EL
EV
AT
OR
P-
CORRIDOR
C2-6
CORRIDOR
C2-8
CO
RR
ID
OR
C2 -7
QA/QC COORD
OFFICE
200A
LAB / OPERATIONS
MGR OFFICE
200B
SUPPLY
TECHNICIAN
OFFICE
200C
CO
NN
EC
TI
ON
CO
RR
ID
OR
MC
-C
CO
RR
ID
OR
C2 -2
ELECTRIC
CLOSET
CL
OS
ET
2A
RED CROSS
VOLUNTEERS
BREAK RM
223A
STAIR
NO 3
PHARMACY/ CONFERENCE
BREAKROOM
223PHARMACIST
OFFICE
219C
RESEARCH
ASST
OFFICE
219BPHARMA
ECONOMIC
FORMULARY
MGMT DRUG INFO
OFFICE
219E
ASST CHIEF
SUPPORT SVCS
OFFICE
219G
PHARMACY
ADMINISTRATIVE
OFFICE
COPY
219H
CONFERENCE RM
CORRIDOR
C2-10
ACTING
CHIEF OF
PATHOLOGY
200Z
STAIR
PGM SUPPORT
OFFICE
200Y
CONFERENCE
RM
200U
CO
RR
ID
OR
C2 -1
PATHOLOGIST
OFFICE
200T
PATHOLOGIST
OFFICE
200S
NURSING OFFICER
OF THE DAY (NOD)
OFFICE
ST
OR
AG
E
3MECH
SHAFT
CHIEF OF
PATHOLOGY
OFFICE
200D
CLOSET
200G
SECY
OFFICE
200E
MULTI-HEADED
MICROSCOPE RM
200H
COPY/ BREAK RM
200F
PATHOLOGY
RESIDENTS
AREA
200K
PATHOLOGY
TRANSCRIPTION
RECORD RM
200L
MI
CR
OS
CO
PE
RM 20
0M
PATHOLOGIST
OFFICE
200N
PATHOLOGIST
OFFICE
200P
PATHOLOGIST
OFFICE
200Q
PATHOLOGIST
OFFICE
200R
STAIR
NO 2
EQ
UI
PM
EN
T
ST
OR
AG
E
ALCOVE
219F
FAC
STORAGE
201P
202P
3P
CENTER
OFFICE
SVC ELEVATOR LOBBY
203A
HZ
HZ
HZ
HZ
HZ
HZ
EX
EX
EX
EX
EX
001.2.01
001.2.02
001.2.03
001.2.04
001.2.05
001.2.06
001.2.07
CORRIDOR
C2-12
1 (TYP)
RISK: HIGH
INFECTION CONTROL PRECAUTION: CLASS III/IV
RISK: HIGH
INFECTION CONTROL PRECAUTION: CLASS III/IV
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Fi le
P at h
U.S. Department of Veterans Affairs
B
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
STAMPCONSULTANT
321 4 5 6 7 8 9 10
Project Director
Revisions: Date:
Key Plan
Electronic Health Records Modernization (EHRM) Infrastructure Upgrades - Long Beach
5901 E. SEVENTH STREET, LONG BEACH, CA 90822
600-20-120
CONTRACT DOCUMENTS
December 16, 2020 JC GB
FULLY SPRINKLERED
NORTH
A
GENERAL NOTES
KEY NOTES
17075 Via Del Campo, San Diego, CA 92127 Phone: 858.946.0333
ARCHITECT/ENGINEER OF RECORD
SCALE: 1/8" = 1'-0" 0' 4' 8' 16'
C
D
20801.10
ARCHITECTURAL SECOND FLOOR
PLAN
ARCHITECTURAL SECOND FLOOR PLAN
1.A-121
NORTH
BUILDING 1
F1
DOOR RATING LEGEND
NON-RATED SMOKE- RESISTANT
FIRE DOOR
20-MINUTE RATED FIRE DOOR
45-MINUTE RATED FIRE DOOR
60-MINUTE RATED FIRE DOOR
90-MINUTE RATED FIRE DOOR
90-MINUTE SMOKE- RESISTANT
FIRE DOOR
180-MINUTE RATED FIRE DOOR
RATED DOOR TAG
(XX:BLDG; YY: LEVEL; Z:ID; W:MINUTES)
EX
EXIT STAIR
HAZARDOUS ROOM (NFPA 101 §8.7)
INTERIOR EXIT LOCATION
EXTERIOR EXIT DISCHARGE
WALL TYPE LEGEND
HZ
3-HR. FIRE BARRIER
2-HR. FIRE/SMOKE BARRIER
1-HR. FIRE/SMOKE BARRIER
SMOKE BARRIER
SMOKE PARTITION
INTERIOR EXIT PASSAGEWAY
LIFE SAFETY LEGEND
1. REMOVE AND REINSTALL CEILING AS REQUIRED FOR
RUNNING CABLING.
1. PROVIDE UL LISTED FIRESTOPPING AT ALL
PENETRATIONS OF FIRE RATED WALLS.
2. USE EZ PATH OR SIMILAR TO ALLOW CABLES TO
PENETRATE WALLS, W/O LIMITING ABILITY TO
ADD/REMOVE CABLES AT A LATER TIME W/O RESEALING.
3. COORDINATE RELOCATION OF EXISTING EQUIPMENT
AND FURNITURE WITH THE VA AS INDICATED ON
PROJECT NOTE 5 ON GI001.
4. BUILDING 1 CONTAINS HAZARDOUS MATERIALS, REFER
TO GI003.
INFECTION CONTROL
NOTES
1. ON THIS PLAN, ALL CORRIDORS ARE CONSTRUCTION
TYPE D, LOW RISK GROUP AND INFECTION CONTROL
CLASS III. WHERE CORRIDOR IS SHOWN WITHIN AREA OF
HIGHER PRECAUTION CLASS, CORRIDOR SHALL MEET
THE MORE STRINGENT REQUIREMENT.
2. ALL OTHER AREAS ON THIS PLAN SHALL BE CONSIDERED
CONSTRUCTION TYPE C, LOW RISK GROUP AND
INFECTION CONTROL PRECAUTION CLASS II UNLESS
OTHERWISE NOTED.
HZ
HZ
HZ
HZ
HZ
HZ
HZ
HZ
HZ
HZ
EX
EX
EX
EX
EX
VESTIBULE
316A
FEMALE TOILET
ELECTRICAL
CLOSET
309A
TOILET
RM
327B
TELE-COMM
CLOSET
315A
302F
DRESSING
RM
323A
LOCKER
327A
CORRIDOR
CORRIDOR
C3-2
CO
RR
ID
OR
C3 -5
CO
RR
ID
OR
C3 -5
A
CORRIDOR
C3-3
CORRIDOR
C3-4
CORRIDOR
C3-4A
STERILE SUPPLY RM
322B
CO
NN
EC
TI
NG
CO
RR
ID
OR
MC
-C
ELEVATOR LOBBY
TOILET
(LIBRARY)
BREAK RM
335C
EL
EV
AT
OR
EL
EV
AT
OR
LIBRARY
STORAGE
335B
LIBRARY
OFFICE
LIBRARY
OFFICE
335A
MALE
TOILET
PASSENGER
ELEVATOR
LOBBY
301D
ORTHO NURSES
OFFICE
301A
ORTHO
STORAGE
301B
ELECTRICAL
RM
301E
ORTHO
WAITING
AREA
301C
ORTHO
RECEPTION
AREA
ORTHO
PHYSICIAN
OFFICE
EQUIPMENT
STORAGE
ORTHO
CHIEFS
OFFICE
OR
TH
O
SE
CR
EA
TA
RY
OF
FI
CE
5 ORTHO
LIBRARY RM
STAIR
ORTHO
CONFERENCE
RM
ORTHO
EXAM RM
307A
ORTHO
EXAM RM
ORTHO
EXAM RM
308A
ORTHO
EXAM RM
ORTHO
CAST RM
ORTHO
STORAGE
310A
ORTHO
CAST RM
310B
ORTHO DR
OFFICE
TELEPHONE
CLOSET
CASE MGR
OFFICE
CATH LAB
WAITING RM
CATH
LAB
OFFICE
314AASST CHIEF
CARDIAC CRITICAL
CARE UNIT
OFFICE
CHIEF CARDIAC
CATH LAB
319A
WORK
STATION
ASST CHIEF
CARDIAC
319B
SOILED
UTILITY
320CONTROL RM
CARDIAC
CATH LAB
EQUIP
RM
322A
STAIR
ELEVATOR
ELEVATOR
ELECTRICAL
VAULT RM
TELE RM
STAIR
BREAK RM
EQUIPMENT
STORAGE
326A
CONFERENCE RM
COPIER
RM
OFFICE
OFFICE
324A
ENTRANCE
REST
ROOM
323D
HAC
323C
CH
IE
F
CA
RD
IO
LO
GY
OF
FI
CE
3B
NO 2
NO 3
P-8
P-7
S-
S-
ALCOVE
323E
TEL
FAC
TELE-COMM
FEC
325A
CENTER
SHAFT
CO
RR
ID
OR
C3 -6
A
CORRIDOR
C3-6
SHAFT
1 (TYP)
D6 A-401
D1 A-401
TELECOM ROOM
RISK: HIGHEST
INFECTION CONTROL PRECAUTION: CLASS IV
RISK: MEDIUM
INFECTION CONTROL PRECAUTION: CLASS III
RISK: LOW
INFECTION CONTROL PRECAUTION: CLASS III
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Fi le
P at h
U.S. Department of Veterans Affairs
B
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
STAMPCONSULTANT
321 4 5 6 7 8 9 10
Project Director
Revisions: Date:
Key Plan
Electronic Health Records Modernization (EHRM) Infrastructure Upgrades - Long Beach
5901 E. SEVENTH STREET, LONG BEACH, CA 90822
600-20-120
CONTRACT DOCUMENTS
December 16, 2020 JC GB
FULLY SPRINKLERED
NORTH
A
GENERAL NOTES
KEY NOTES
17075 Via Del Campo, San Diego, CA 92127 Phone: 858.946.0333
ARCHITECT/ENGINEER OF RECORD
SCALE: 1/8" = 1'-0" 0' 4' 8' 16'
C
D
20801.10
ARCHITECTUAL THIRD FLOOR PLAN
ARCHITECTUAL THIRD FLOOR PLAN
1.A-131
NORTH
1. REMOVE AND REINSTALL CEILING AS REQUIRED FOR
RUNNING CABLING.
BUILDING 1
F1
DOOR RATING LEGEND
NON-RATED SMOKE- RESISTANT
FIRE DOOR
20-MINUTE RATED FIRE DOOR
45-MINUTE RATED FIRE DOOR
60-MINUTE RATED FIRE DOOR
90-MINUTE RATED FIRE DOOR
90-MINUTE SMOKE- RESISTANT
FIRE DOOR
180-MINUTE RATED FIRE DOOR
RATED DOOR TAG
(XX:BLDG; YY: LEVEL; Z:ID; W:MINUTES)
EX
EXIT STAIR
HAZARDOUS ROOM (NFPA 101 §8.7)
INTERIOR EXIT LOCATION
EXTERIOR EXIT DISCHARGE
WALL TYPE LEGEND
HZ
3-HR. FIRE BARRIER
2-HR. FIRE/SMOKE BARRIER
1-HR. FIRE/SMOKE BARRIER
SMOKE BARRIER
SMOKE PARTITION
INTERIOR EXIT PASSAGEWAY
LIFE SAFETY LEGEND
1. PROVIDE UL LISTED FIRESTOPPING AT ALL
PENETRATIONS OF FIRE RATED WALLS.
2. USE EZ PATH OR SIMILAR TO ALLOW CABLES TO
PENETRATE WALLS, W/O LIMITING ABILITY TO
ADD/REMOVE CABLES AT A LATER TIME W/O RESEALING.
3. COORDINATE RELOCATION OF EXISTING EQUIPMENT
AND FURNITURE WITH THE VA AS INDICATED ON
PROJECT NOTE 5 ON GI001.
4. BUILDING 1 CONTAINS HAZARDOUS MATERIALS, REFER
TO GI003.
INFECTION CONTROL
NOTES
1. ON THIS PLAN, ALL CORRIDORS ARE CONSTRUCTION
TYPE D, LOW RISK GROUP AND INFECTION CONTROL
CLASS III. WHERE CORRIDOR IS SHOWN WITHIN AREA OF
HIGHER PRECAUTION CLASS, CORRIDOR SHALL MEET
THE MORE STRINGENT REQUIREMENT.
2. ALL OTHER AREAS ON THIS PLAN SHALL BE CONSIDERED
CONSTRUCTION TYPE C, LOW RISK GROUP AND
INFECTION CONTROL PRECAUTION CLASS II UNLESS
OTHERWISE NOTED.
MENS
TOILET
WOMENS
TOILET
ELECTRIC
CLOSET
EEO MGR
CORRIDOR
C4-4
SMALL CONF
RM
ST
OR
AG
E
RM 42
MECH HVAC RM
CORRIDOR
C4-1
SVC ELEVATOR
LOBBY
PASSENGER
ELEVATOR
LOBBY
CORRIDOR
C4-2
ADMIN
PRIMARY CARE
OFFICE
STAIR
EL
EV
AT
OR
S-
EL
EV
AT
OR
S-
BREAK RM
403A
COMPLIANCE
OFFICE
FI
LE
S
TO
RA
GE
R M
ELEVATOR
P-7
ELEVATOR
P-8
MEDICINE
OFFICE
402 RESTROOM
EEO
RECORDS
SECY
OFFICE
OFFICE RM
423A
MECH
SHAFT
OFFICE RM
CONFERENCE
RM
419B
CHIEF OF
PATIENT
CARE SVCS
CHIEF
OF
MEDICINE
PUBLIC
RELATIONS
AD
MI
NI
ST
RA
TI
VE
OF
FI
CE
FAC
DIRECTOR OF
PUBLIC
AFFAIRS
OFFICE
REGIONAL
COUNCIL
ADMIN
OFFICER
CHIEF OF
STAFF
CONFERENCE
409A EEO
OFFICE
409B
OFFICE RM
OFFICE RM
OFFICE RM
OFFICE RM
FAC
NO-3
STAIR
NO-2
STAIR
EC
OFFICE RM
OFFICE RM
OFFICE RM
OFFICE RM
OFFICE RM
CHIEF OFFICE RM
OFFICE RM
445A
OFFICE RM
OFFICE RM
OFFICE RM
OFFICE RM
OFFICE RM
OFFICE RM
OFFICE RM
BREAK RM
ST
OR
AG
E
RM 42
OFFICE RM
OFFICE RM
CORRIDOR
C4-7
CORRIDOR
C4-5
CO
RR
ID
OR
C4 -9
CORRIDOR
C4-6
432A
CENTER
COPY
CORRIDOR
HZ
HZ
HZ
HZ
HZ
EX
EX
EX1 (TYP)
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Fi le
P at h
U.S. Department of Veterans Affairs
B
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
STAMPCONSULTANT
321 4 5 6 7 8 9 10
Project Director
Revisions: Date:
Key Plan
Electronic Health Records Modernization (EHRM) Infrastructure Upgrades - Long Beach
5901 E. SEVENTH STREET, LONG BEACH, CA 90822
600-20-120
CONTRACT DOCUMENTS
December 16, 2020 JC GB
FULLY SPRINKLERED
NORTH
A
GENERAL NOTES
KEY NOTES
17075 Via Del Campo, San Diego, CA 92127 Phone: 858.946.0333
ARCHITECT/ENGINEER OF RECORD
SCALE: 1/8" = 1'-0" 0' 4' 8' 16'
C
D
20801.10
ARCHITECTURAL FOURTH FLOOR
PLAN
ARCHITECTURAL FOURTH FLOOR PLAN
1.A-141
NORTH
BUILDING 1
1. REMOVE AND REINSTALL CEILING AS REQUIRED FOR
RUNNING CABLING.
F1
DOOR RATING LEGEND
NON-RATED SMOKE- RESISTANT
FIRE DOOR
20-MINUTE RATED FIRE DOOR
45-MINUTE RATED FIRE DOOR
60-MINUTE RATED FIRE DOOR
90-MINUTE RATED FIRE DOOR
90-MINUTE SMOKE- RESISTANT
FIRE DOOR
180-MINUTE RATED FIRE DOOR
RATED DOOR TAG
(XX:BLDG; YY: LEVEL; Z:ID; W:MINUTES)
EX
EXIT STAIR
HAZARDOUS ROOM (NFPA 101 §8.7)
INTERIOR EXIT LOCATION
EXTERIOR EXIT DISCHARGE
WALL TYPE LEGEND
HZ
3-HR. FIRE BARRIER
2-HR. FIRE/SMOKE BARRIER
1-HR. FIRE/SMOKE BARRIER
SMOKE BARRIER
SMOKE PARTITION
INTERIOR EXIT PASSAGEWAY
LIFE SAFETY LEGEND
1. PROVIDE UL LISTED FIRESTOPPING AT ALL
PENETRATIONS OF FIRE RATED WALLS.
2. USE EZ PATH OR SIMILAR TO ALLOW CABLES TO
PENETRATE WALLS, W/O LIMITING ABILITY TO
ADD/REMOVE CABLES AT A LATER TIME W/O RESEALING.
3. COORDINATE RELOCATION OF EXISTING EQUIPMENT
AND FURNITURE WITH THE VA AS INDICATED ON
PROJECT NOTE 5 ON GI001.
4. BUILDING 1 CONTAINS HAZARDOUS MATERIALS, REFER
TO GI003.
INFECTION CONTROL
NOTES
1. ON THIS PLAN, ALL CORRIDORS ARE CONSTRUCTION
TYPE D, LOW RISK GROUP AND INFECTION CONTROL
CLASS III. WHERE CORRIDOR IS SHOWN WITHIN AREA OF
HIGHER PRECAUTION CLASS, CORRIDOR SHALL MEET
THE MORE STRINGENT REQUIREMENT.
2. ALL OTHER AREAS ON THIS PLAN SHALL BE CONSIDERED
CONSTRUCTION TYPE C, LOW RISK GROUP AND
INFECTION CONTROL PRECAUTION CLASS II UNLESS
OTHERWISE NOTED.
501A
504C
P-8
P-7
0A
STORAGE
CL
OS
ET
STORAGE
FAC
SVC
ELEVATORS
MECH RM
KITCHENETTE
ELEVATOR
LOBBY
PASSENGER
TOILET
STAIRWELL
ELEVATOR
ELEVATOR
OFFICE OF DATA
COLLECTION
MANAGEMENT
(OCDA)
ME
CH
R M
EX
001.5.01
1 (TYP)
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Fi le
P at h
U.S. Department of Veterans Affairs
B
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
STAMPCONSULTANT
321 4 5 6 7 8 9 10
Project Director
Revisions: Date:
Key Plan
Electronic Health Records Modernization (EHRM) Infrastructure Upgrades - Long Beach
5901 E. SEVENTH STREET, LONG BEACH, CA 90822
600-20-120
CONTRACT DOCUMENTS
December 16, 2020 JC GB
FULLY SPRINKLERED
NORTH
A
GENERAL NOTES
KEY NOTES
17075 Via Del Campo, San Diego, CA 92127 Phone: 858.946.0333
ARCHITECT/ENGINEER OF RECORD
SCALE: 1/8" = 1'-0" 0' 4' 8' 16'
C
D
20801.10
ARCHITECTURAL FIFTH FLOOR
PLAN
ARCHITECTURAL FIFTH FLOOR PLAN
1.A-151
NORTH
BUILDING 1
1. REMOVE AND REINSTALL CEILING AS REQUIRED FOR
RUNNING CABLING.
F1
DOOR RATING LEGEND
NON-RATED SMOKE- RESISTANT
FIRE DOOR
20-MINUTE RATED FIRE DOOR
45-MINUTE RATED FIRE DOOR
60-MINUTE RATED FIRE DOOR
90-MINUTE RATED FIRE DOOR
90-MINUTE SMOKE- RESISTANT
FIRE DOOR
180-MINUTE RATED FIRE DOOR
RATED DOOR TAG
(XX:BLDG; YY: LEVEL; Z:ID; W:MINUTES)
EX
EXIT STAIR
HAZARDOUS ROOM (NFPA 101 §8.7)
INTERIOR EXIT LOCATION
EXTERIOR EXIT DISCHARGE
WALL TYPE LEGEND
HZ
3-HR. FIRE BARRIER
2-HR. FIRE/SMOKE BARRIER
1-HR. FIRE/SMOKE BARRIER
SMOKE BARRIER
SMOKE PARTITION
INTERIOR EXIT PASSAGEWAY
LIFE SAFETY LEGEND
1. PROVIDE UL LISTED FIRESTOPPING AT ALL
PENETRATIONS OF FIRE RATED WALLS.
2. USE EZ PATH OR SIMILAR TO ALLOW CABLES TO
PENETRATE WALLS, W/O LIMITING ABILITY TO
ADD/REMOVE CABLES AT A LATER TIME W/O RESEALING.
3. COORDINATE RELOCATION OF EXISTING EQUIPMENT
AND FURNITURE WITH THE VA AS INDICATED ON
PROJECT NOTE 5 ON GI001.
4. BUILDING 1 CONTAINS HAZARDOUS MATERIALS, REFER
TO GI003.
INFECTION CONTROL
NOTES
1. ALL AREAS ON THIS PLAN SHALL BE CONSIDERED
CONSTRUCTION TYPE C, LOW RISK GROUP AND
INFECTION CONTROL PRECAUTION CLASS II UNLESS
OTHERWISE NOTED.
2. REFER TO SHEET GI004 THRU GI007 FOR ASSOCIATED
FEMALE
EL
EC
TR
IC
AL
RM
AUTOPSY RM
AUTOPSY RM
EQUIPMENT
STORAGE
FILE
STORAGE
CO
RR
ID
OR
CC
2-
B1
CO
RR
ID
OR
CC
2- B1
ELECTRICAL VAULT
TRANSFORMER
52A
ELECTRICAL RM
CORRIDOR
CC2-B4
S P D STORAGE AREA
ENVIRONMENTAL
STORAGE
EMPLOYEE BREAK RM
MALE TOILET
CORRIDOR
CC2-B5
TEMP STORAGE FOR
TELEHEALTH
STORAGE
(ELECTRICAL TV)
38A
IR
M
RM
(E
LE
CT
RI
CA
L T V)
ENTRANCE
MORGUE
37A
CORRIDOR
CC-2-BM1
MALE TOILET
HAC RM
MORGUE
OFFICE
FEMALE
TOILET
REFRIGERATED RM
ELECTRICAL RM
42A
SPECIMEN
STORAGE
46A
AUTOPSY RM
REPRODUCTION
AREA
49FAN RM
48-A
CORRIDOR
CC2-B2
UNIFORM ISSUE AND
CENTRAL LINEN RM
FAN RM
UN
IF
OR
M
RM 50
-H
UN
IF
OR
M
RM 50
-I
LAUNDRY AREA
WASHER EXTRACTOR
50-K
LAUNDRY AREA DRY
AND PRESSING RM
50-J
CORRIDOR
CC2-B3
CANTEEN
STORAGE
50-A
ELECTRICAL
CLOSET
50-L
TEXTILE
CARE
SUPERVISOR
OFFICE
50-G
OFFICE
50-F
EMPL
LOUNGE
50-E
SEWING AND
SCRUB RM
50-CST
OR
AG
E
-C
C
ST
OR
AG
E
-B
BSTORAGE
50-B
SHAFT
SHAFT
HOT WATER TANKS/
PUMP AREA
BED SHOP
UNIFORM
PACKING RM
STAIR
FEMALE TOILET
FEMALE LOCKER
48-A
ANTE RM
49-A
50-D
56B
MALE LOCKER
56A
HAC
50-AA
C
52B
EX EX
EX
HZ
HZ HZ HZ
HZ
HZ
HZ
HZ
HZ
HZ
HZ
HZ
HZ
HZ
HZ
HZ
HZ
HZ
002.B.01
002.B.02
002.B.03
1 (TYP)
RISK: HIGH
INFECTION CONTROL PRECAUTION: CLASS IV
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Fi le
P at h
U.S. Department of Veterans Affairs
B
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
STAMPCONSULTANT
321 4 5 6 7 8 9 10
Project Director
Revisions: Date:
Key Plan
Electronic Health Records Modernization (EHRM) Infrastructure Upgrades - Long Beach
5901 E. SEVENTH STREET, LONG BEACH, CA 90822
600-20-120
CONTRACT DOCUMENTS
December 16, 2020 JC GB
FULLY SPRINKLERED
NORTH
A
GENERAL NOTES
KEY NOTES
17075 Via Del Campo, San Diego, CA 92127 Phone: 858.946.0333
ARCHITECT/ENGINEER OF RECORD
0' 4' 16' 24'2' 8'SCALE: 3/32" = 1'-0"
C
D
20801.10
ARCHITECTURAL BASEMENT
FLOOR PLAN
ARCHITECTURAL BASEMENT FLOOR PLAN
2.A-101
NORTH
1. REMOVE AND REINSTALL CEILING AS REQUIRED FOR
RUNNING CABLING.
2. EUD'S AND CABLES TO REMAIN. SEE REF-01.
BUILDING 2
F1
DOOR RATING LEGEND
NON-RATED SMOKE- RESISTANT
FIRE DOOR
20-MINUTE RATED FIRE DOOR
45-MINUTE RATED FIRE DOOR
60-MINUTE RATED FIRE DOOR
90-MINUTE RATED FIRE DOOR
90-MINUTE SMOKE- RESISTANT
FIRE DOOR
180-MINUTE RATED FIRE DOOR
RATED DOOR TAG
(XX:BLDG; YY: LEVEL; Z:ID; W:MINUTES)
EX
EXIT STAIR
HAZARDOUS ROOM (NFPA 101 §8.7)
INTERIOR EXIT LOCATION
EXTERIOR EXIT DISCHARGE
WALL TYPE LEGEND
HZ
3-HR. FIRE BARRIER
2-HR. FIRE/SMOKE BARRIER
1-HR. FIRE/SMOKE BARRIER
SMOKE BARRIER
SMOKE PARTITION
INTERIOR EXIT PASSAGEWAY
LIFE SAFETY LEGEND
1. PROVIDE UL LISTED FIRESTOPPING AT ALL
PENETRATIONS OF FIRE RATED WALLS.
2. USE EZ PATH OR SIMILAR TO ALLOW CABLES TO
PENETRATE WALLS, W/O LIMITING ABILITY TO
ADD/REMOVE CABLES AT A LATER TIME W/O RESEALING.
3. COORDINATE RELOCATION OF EXISTING EQUIPMENT
AND FURNITURE WITH THE VA AS INDICATED ON
PROJECT NOTE 5 ON GI001.
4. BUILDING 2 CONTAINS HAZARDOUS MATERIALS, REFER
TO GI003.
INFECTION CONTROL
NOTES
1. ALL AREAS ON THIS PLAN SHALL BE CONSIDERED
CONSTRUCTION TYPE D, LOW RISK GROUP AND
INFECTION CONTROL PRECAUTION CLASS IV UNLESS
OTHERWISE NOTED.
TELECOM ROOM IN SCOPE
EL
EC
TR
IC
AL
BREAK RM
PHARMACY CACHE
EMPLOYEE WELLNESS CENTER
WAREHOUSE
STORAGE
121E
WAREHOUSE
STORAGE
EQUIPMENT STORAGE
CALL CENTER PRIMARY
CARE
108A
EXAM RM
N-122A
CO
RR
ID
OR
CC
2-
1-
SOUND
BOOTH
SOUND
RM 2
N-158C
SOUND
RM1
N-158D
SO
UN
D
RM
N-
0A
FAC
OFFICE
N-161
RECEPTION
N-159A
LAB
N-163
OFFICE
N-164CONFERENCE
RM
N-159
OFFICE
N-165
TELECLOSET
NC1-1A
WOMENS
RESTROOM
N-156
SOUND
BOOTH
N-157
VESTIBULE
OFFICE
CHIEF
AUDITORY
RESEARCH
N-157C
OFFICE
N-157B
OFFICE
N-157A
SOUND
RM 4
N-158A
SOUND
RM 3
N-158B
VAULT
EXAM RM
N-122B
GE
NE
RA
L
ST
OR
AG
E
N-
2C
OFFICE
N-122D
FAC
SOUND
BOOTH
RESIDENT
OFFICE
N-119
WORK RM
ENT
ATTENDING
ENT RM
N-118
WAITING AREA
N-126
RECEPTION
AREA
N-125
SOILED
UTILITY
N-124
CLEAN
UTILITY
N-123
PROCEDURE
RM
N-122
FEMALE
TOILET
N-120
MALE
TOILET
N-121
FE
MA
LE
RE
ST
RO
OM
N-
CLINIC
NURSE
CO-ORDR
OFFICE
N-106
EXAM RM 1
N-107
EXAM RM 2
N-108EXAM
RM 3
N-109
EXAM
RM 4
N-110
EQ
UI
PM
EN
T
ST
OR
AG
E N-
EXAM RM 5
EXAM RM 6
N-113
EXAM RM 7
N-114
OFFICE
N-115
SECY
OTOLARYNGOLOGY
CLINIC
N-116
CONFERENCE RM
N-117
CREDIT UNION
CANTEEN
BARBER
SHOP
TRANSFER CO-ORDER
FIT OFFICE
118A
OFFICE
E104
RECEPTION
MALE TOILET
E103
FEMALE TOILET
E102
TOILET
SOUND
RM
CORRIDOR
N-122
FIRE
APPARATUS
CORRIDOR
PHARMACY
OFFICE
CREDIT UNION
CORRIDORN-112
E101
166A166B
STORAGE
N-137
CONTROL
RM
N-160
TRASH
10A
CO
RR
ID
OR
CC
2-
1-
FCC
FCC
CORRIDOR
CC2-1-3
CORRIDOR CC2-1-6
CORRIDOR
CC2-1-5
STORAGE
WAITING
AREA
CASHIER
OFFICE
HZ
HZ HZ
HZ
HZ
EX
EX
EX
EX
EX
EX
EX
EX
EX
002.1.01
002.1.02
002.1.03
002.1.05
EX
TELECOM
ROOM
N108A
1 (TYP)
RISK: MEDIUM
INFECTION CONTROL PRECAUTION: CLASS IV
RISK: MEDIUM
INFECTION CONTROL PRECAUTION: CLASS IV
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Fi le
P at h
U.S. Department of Veterans Affairs
B
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
STAMPCONSULTANT
321 4 5 6 7 8 9 10
Project Director
Revisions: Date:
Key Plan
Electronic Health Records Modernization (EHRM) Infrastructure Upgrades - Long Beach
5901 E. SEVENTH STREET, LONG BEACH, CA 90822
600-20-120
CONTRACT DOCUMENTS
December 16, 2020 JC GB
FULLY SPRINKLERED
NORTH
A
GENERAL NOTES
KEY NOTES
17075 Via Del Campo, San Diego, CA 92127 Phone: 858.946.0333
ARCHITECT/ENGINEER OF RECORD
0' 4' 16' 24'2' 8'SCALE: 3/32" = 1'-0"
C
D
20801.10
ARCHITECTURAL FIRST FLOOR
PLAN
ARCHITECTURAL FIRST FLOOR PLAN
2.A-111
NORTH
1. REMOVE AND REINSTALL CEILING AS REQUIRED FOR
RUNNING CABLING.
BUILDING 2
F1
E4 A-402
B4 A-402
DOOR RATING LEGEND
NON-RATED SMOKE- RESISTANT
FIRE DOOR
20-MINUTE RATED FIRE DOOR
45-MINUTE RATED FIRE DOOR
60-MINUTE RATED FIRE DOOR
90-MINUTE RATED FIRE DOOR
90-MINUTE SMOKE- RESISTANT
FIRE DOOR
180-MINUTE RATED FIRE DOOR
RATED DOOR TAG
(XX:BLDG; YY: LEVEL; Z:ID; W:MINUTES)
EX
EXIT STAIR
HAZARDOUS ROOM (NFPA 101 §8.7)
INTERIOR EXIT LOCATION
EXTERIOR EXIT DISCHARGE
WALL TYPE LEGEND
HZ
3-HR. FIRE BARRIER
2-HR. FIRE/SMOKE BARRIER
1-HR. FIRE/SMOKE BARRIER
SMOKE BARRIER
SMOKE PARTITION
INTERIOR EXIT PASSAGEWAY
LIFE SAFETY LEGEND
1. PROVIDE UL LISTED FIRESTOPPING AT ALL
PENETRATIONS OF FIRE RATED WALLS.
2. USE EZ PATH OR SIMILAR TO ALLOW CABLES TO
PENETRATE WALLS, W/O LIMITING ABILITY TO
ADD/REMOVE CABLES AT A LATER TIME W/O RESEALING.
3. COORDINATE RELOCATION OF EXISTING EQUIPMENT
AND FURNITURE WITH THE VA AS INDICATED ON
PROJECT NOTE 5 ON GI001.
4. BUILDING 2 CONTAINS HAZARDOUS MATERIALS, REFER
TO GI003.
INFECTION CONTROL
NOTES
1. ALL AREAS ON THIS PLAN SHALL BE CONSIDERED
CONSTRUCTION TYPE D, LOW RISK GROUP AND
INFECTION CONTROL PRECAUTION CLASS IV UNLESS
OTHERWISE NOTED.
FEMALE
TOILET
TOILET
CO
RR
ID
OR
CC
2-
2-
CHAPLAIN SERVICE
ALTAR
247A
CHAPEL AREA
CO
RR
ID
OR
CC
2-
2-
CORRIDOR
CC2-2-4
PHARMACY
SUPPLIES
214-P
ALCOHOL
RM
211-P
VAULT
212-P
RESEARCH
PHARMACY
213-P
OFFICE
204-P
PRAYER
RM
LOUNGE
OFFICE
SECRETARY
CHAPLAIN
SERVICE
CHAPLAIN
OFFICE
CHAPLAIN
OFFICE
243STORAGE
CHAPLAIN
OFFICE
CHIEF
CHAPLAIN
SVC OFFICE
STORAGE
247C
STORAGE
247B
MALE
KITCHEN
GENERAL
STORAGE
EQUIPMENT
STORAGE
PANTAGES THEATER
STAIR
CO
RR
ID
OR
CC
2-
2-
5STAGE
DR
ES
SI
NG
RM 26
ST
AI
R
STAIR
GENERAL
STORAGE
HR
FILES
HAC
205-P
215-P
206-P
OFFICE
210-P
SHAFT
SHAFT
SHAFT
PHARMACY
PHARMACY
PHARMACY
HZ
HZ
HZ
HZ
HZHZ
HZ
HZ
HZ
HZ
HZ
HZ
EX
EX
EX EX EX
EX
EX
EX
HZEX
HZ
HZ
1 (TYP)
RISK: HIGH
INFECTION CONTROL PRECAUTION: CLASS IV
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Fi le
P at h
U.S. Department of Veterans Affairs
B
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
STAMPCONSULTANT
321 4 5 6 7 8 9 10
Project Director
Revisions: Date:
Key Plan
Electronic Health Records Modernization (EHRM) Infrastructure Upgrades - Long Beach
5901 E. SEVENTH STREET, LONG BEACH, CA 90822
600-20-120
CONTRACT DOCUMENTS
December 16, 2020 JC GB
FULLY SPRINKLERED
NORTH
A
GENERAL NOTES
KEY NOTES
17075 Via Del Campo, San Diego, CA 92127 Phone: 858.946.0333
ARCHITECT/ENGINEER OF RECORD
0' 4' 16' 24'2' 8'SCALE: 3/32" = 1'-0"
C
D
20801.10
ARCHITECTURAL SECOND FLOOR
PLAN
ARCHITECTURAL SECOND FLOOR PLAN
2.A-121
NORTH
1. REMOVE AND REINSTALL CEILING AS REQUIRED FOR
RUNNING CABLING.
BUILDING 2
F1
DOOR RATING LEGEND
NON-RATED SMOKE- RESISTANT
FIRE DOOR
20-MINUTE RATED FIRE DOOR
45-MINUTE RATED FIRE DOOR
60-MINUTE RATED FIRE DOOR
90-MINUTE RATED FIRE DOOR
90-MINUTE SMOKE- RESISTANT
FIRE DOOR
180-MINUTE RATED FIRE DOOR
RATED DOOR TAG
(XX:BLDG; YY: LEVEL; Z:ID; W:MINUTES)
EX
EXIT STAIR
HAZARDOUS ROOM (NFPA 101 §8.7)
INTERIOR EXIT LOCATION
EXTERIOR EXIT DISCHARGE
WALL TYPE LEGEND
HZ
3-HR. FIRE BARRIER
2-HR. FIRE/SMOKE BARRIER
1-HR. FIRE/SMOKE BARRIER
SMOKE BARRIER
SMOKE PARTITION
INTERIOR EXIT PASSAGEWAY
LIFE SAFETY LEGEND
1. PROVIDE UL LISTED FIRESTOPPING AT ALL
PENETRATIONS OF FIRE RATED WALLS.
2. USE EZ PATH OR SIMILAR TO ALLOW CABLES TO
PENETRATE WALLS, W/O LIMITING ABILITY TO
ADD/REMOVE CABLES AT A LATER TIME W/O RESEALING.
3. COORDINATE RELOCATION OF EXISTING EQUIPMENT
AND FURNITURE WITH THE VA AS INDICATED ON
PROJECT NOTE 5 ON GI001.
4. BUILDING 2 CONTAINS HAZARDOUS MATERIALS, REFER
TO GI003.
INFECTION CONTROL
NOTES
1. ALL AREAS ON THIS PLAN SHALL BE CONSIDERED
CONSTRUCTION TYPE D, LOW RISK GROUP AND
INFECTION CONTROL PRECAUTION CLASS IV UNLESS
OTHERWISE NOTED.
ST
OR
AG
E
RESTROOM
MENS RESTROOM
STAIR
ST
AI
R
9STORAGE
STAIR
LIBRARY
305A
LIBRARIAN
OFFICE
345D
HVAC FAN RM
ADMIN
COMPUTER RM
346B
CONFERENCE
RM
346A
304K
OFFICE
OFFICE
304C
SYSTEMS
REDESIGN
304B
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
304F
304E
304D
OFFICE
304A
304JCO
RR
ID
OR
304G
304H
RADIO RM
STORAGE
STORAGE
STORAGE
PROJECTOR
RM
CO
RR
ID
OR
FIRE APPARATUS
351A
352A
CHECKOUT
345A
HZ
EX
EX
002.3.01
HZ HZ
HZ
HZ
002.3.02 45 002.3.03
1 (TYP)
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Fi le
P at h
U.S. Department of Veterans Affairs
B
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
STAMPCONSULTANT
321 4 5 6 7 8 9 10
Project Director
Revisions: Date:
Key Plan
Electronic Health Records Modernization (EHRM) Infrastructure Upgrades - Long Beach
5901 E. SEVENTH STREET, LONG BEACH, CA 90822
600-20-120
CONTRACT DOCUMENTS
December 16, 2020 JC GB
FULLY SPRINKLERED
NORTH
A
GENERAL NOTES
KEY NOTES
17075 Via Del Campo, San Diego, CA 92127 Phone: 858.946.0333
ARCHITECT/ENGINEER OF RECORD
0' 4' 16' 24'2' 8'SCALE: 3/32" = 1'-0"
C
D
20801.10
ARCHITECTURAL THIRD FLOOR
PLAN
ARCHITECTURAL THIRD FLOOR PLAN
2.A-131
NORTH
1. REMOVE AND REINSTALL CEILING AS REQUIRED FOR
RUNNING CABLING.
BUILDING 2
F1
DOOR RATING LEGEND
NON-RATED SMOKE- RESISTANT
FIRE DOOR
20-MINUTE RATED FIRE DOOR
45-MINUTE RATED FIRE DOOR
60-MINUTE RATED FIRE DOOR
90-MINUTE RATED FIRE DOOR
90-MINUTE SMOKE- RESISTANT
FIRE DOOR
180-MINUTE RATED FIRE DOOR
RATED DOOR TAG
(XX:BLDG; YY: LEVEL; Z:ID; W:MINUTES)
EX
EXIT STAIR
HAZARDOUS ROOM (NFPA 101 §8.7)
INTERIOR EXIT LOCATION
EXTERIOR EXIT DISCHARGE
WALL TYPE LEGEND
HZ
3-HR. FIRE BARRIER
2-HR. FIRE/SMOKE BARRIER
1-HR. FIRE/SMOKE BARRIER
SMOKE BARRIER
SMOKE PARTITION
INTERIOR EXIT PASSAGEWAY
LIFE SAFETY LEGEND
1. PROVIDE UL LISTED FIRESTOPPING AT ALL
PENETRATIONS OF FIRE RATED WALLS.
2. USE EZ PATH OR SIMILAR TO ALLOW CABLES TO
PENETRATE WALLS, W/O LIMITING ABILITY TO
ADD/REMOVE CABLES AT A LATER TIME W/O RESEALING.
3. COORDINATE RELOCATION OF EXISTING EQUIPMENT
AND FURNITURE WITH THE VA AS INDICATED ON
PROJECT NOTE 5 ON GI001.
4. BUILDING 2 CONTAINS HAZARDOUS MATERIALS, REFER
TO GI003.
INFECTION CONTROL
NOTES
1. ALL AREAS ON THIS PLAN SHALL BE CONSIDERED
CONSTRUCTION TYPE D, LOW RISK GROUP AND
INFECTION CONTROL PRECAUTION CLASS IV UNLESS
OTHERWISE NOTED.
BREAK
E-125
SAMPLES
E-105
FILES
STORAGE
HA
LL
W
AY
E-
HALLWAY
P-101
HA
LL
W
AY
P-
BREAK
P-120
LOBBY
P-100
COUNTER
P-102
PRINT/FAX
P-110
HALLWAY
E-100
HA
LL
W
AY
E-
HALLWAY
E-124
BREAK
E-128
CORRIDOR
E-102
REPORT
P-109
SGT
P-108
CAPT
P-107
CAPT
P-106
CHIEF
P-105ADMIN
P-103
TRAINING/
ARMORY
P-122
COMM
P-124
DISPATCHER
P-123
CLASSROOM/
COMMAND
CENTER
P-125
MENS LOCKER
P-117
WOMENS TOILET
P-116
WOMENS
LOCKER
P-115
JAN
P-114
IT RM
E-107
CONFERENCE RM
E-106
MENS TOILET
P-118
MENS TOILET
E-126
DRAWING STORAGE
E-123
WOMENS TOILET
E-127
ELECTRICAL
CLOSET
E-131
COPY/FAX
E-130
HAC
E-129
HOLD
P-113
STORAGE
P-112 INVEST
P-111
MECH
E-132
IT/DATA
E-108
ENG
E-109
ENG
E-110
ENG
E-111
ENG
E-112
CLERK
E-113
SR RES
E-114RES ENG
E-115
RES ENG
E-116
RES ENG
E-117
ID CHIEF
E-104
CONFERENCE
RM
E-118
CAD ENG
E-122
ENG
E-121
LIBRARY
E-120
COPY/ FAX
E-119
TELECOM ROOM
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Fi le
P at h
U.S. Department of Veterans Affairs
B
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
STAMPCONSULTANT
321 4 5 6 7 8 9 10
Project Director
Revisions: Date:
Key Plan
Electronic Health Records Modernization (EHRM) Infrastructure Upgrades - Long Beach
5901 E. SEVENTH STREET, LONG BEACH, CA 90822
600-20-120
CONTRACT DOCUMENTS
December 16, 2020 JC GB
FULLY SPRINKLERED
NORTH
A
GENERAL NOTES
KEY NOTES
17075 Via Del Campo, San Diego, CA 92127 Phone: 858.946.0333
ARCHITECT/ENGINEER OF RECORD
SCALE: 1/8" = 1'-0" 0' 4' 8' 16'
C
D
20801.10
ARCHITECTURAL FIRST FLOOR
PLAN
ARCHITECTURAL FIRST FLOOR PLAN
5C.A-111
NORTH
5C
BUILDING 5C
F1
E7 A-402
B7 A-402
DOOR RATING LEGEND
NON-RATED SMOKE- RESISTANT
FIRE DOOR
20-MINUTE RATED FIRE DOOR
45-MINUTE RATED FIRE DOOR
60-MINUTE RATED FIRE DOOR
90-MINUTE RATED FIRE DOOR
90-MINUTE SMOKE- RESISTANT
FIRE DOOR
180-MINUTE RATED FIRE DOOR
RATED DOOR TAG
(XX:BLDG; YY: LEVEL; Z:ID; W:MINUTES)
EX
EXIT STAIR
HAZARDOUS ROOM (NFPA 101 §8.7)
INTERIOR EXIT LOCATION
EXTERIOR EXIT DISCHARGE
WALL TYPE LEGEND
HZ
3-HR. FIRE BARRIER
2-HR. FIRE/SMOKE BARRIER
1-HR. FIRE/SMOKE BARRIER
SMOKE BARRIER
SMOKE PARTITION
INTERIOR EXIT PASSAGEWAY
LIFE SAFETY LEGEND
INFECTION CONTROL
NOTES
1. ALL AREAS ON THIS PLAN SHALL BE CONSIDERED
CONSTRUCTION TYPE C, LOW RISK GROUP AND
INFECTION CONTROL PRECAUTION CLASS II UNLESS
OTHERWISE NOTED.
TELEPHONE
GENERAL
MECHANIC
SHOP
ENGINEERING SHOPS
STORAGE
TOILET
WELDING SHOP
GENERAL MECHANIC SHOP
BREAK RM
STORAGE
PIPE SHOP
SUPERVISOR
MOTOR POOL
OFFICE
OFFICE
OFFICE
VAULT
BREAK RM
GENERAL
STORAGE
TOILET
TOILET
HVAC SHOP
STORAGE
ELECTRICAL RM
38A
TELECOM ROOM
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Fi le
P at h
U.S. Department of Veterans Affairs
B
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
STAMPCONSULTANT
321 4 5 6 7 8 9 10
Project Director
Revisions: Date:
Key Plan
Electronic Health Records Modernization (EHRM) Infrastructure Upgrades - Long Beach
5901 E. SEVENTH STREET, LONG BEACH, CA 90822
600-20-120
CONTRACT DOCUMENTS
December 16, 2020 JC GB
FULLY SPRINKLERED
NORTH
A
GENERAL NOTES
KEY NOTES
17075 Via Del Campo, San Diego, CA 92127 Phone: 858.946.0333
ARCHITECT/ENGINEER OF RECORD
0' 4' 16' 24'2' 8'SCALE: 3/32" = 1'-0"
C
D
20801.10
ARCHITECTURAL FIRST FLOOR
PLAN
ARCHITECTURAL FIRST FLOOR PLAN
6.A-111
NORTH
BUILDING 6
F1
E1 A-403
B1 A-403
DOOR RATING LEGEND
NON-RATED SMOKE- RESISTANT
FIRE DOOR
20-MINUTE RATED FIRE DOOR
45-MINUTE RATED FIRE DOOR
60-MINUTE RATED FIRE DOOR
90-MINUTE RATED FIRE DOOR
90-MINUTE SMOKE- RESISTANT
FIRE DOOR
180-MINUTE RATED FIRE DOOR
RATED DOOR TAG
(XX:BLDG; YY: LEVEL; Z:ID; W:MINUTES)
EX
EXIT STAIR
HAZARDOUS ROOM (NFPA 101 §8.7)
INTERIOR EXIT LOCATION
EXTERIOR EXIT DISCHARGE
WALL TYPE LEGEND
HZ
3-HR. FIRE BARRIER
2-HR. FIRE/SMOKE BARRIER
1-HR. FIRE/SMOKE BARRIER
SMOKE BARRIER
SMOKE PARTITION
INTERIOR EXIT PASSAGEWAY
LIFE SAFETY LEGEND
1. BUILDING 6 CONTAINS HAZARDOUS MATERIALS, REFER
TO GI003.
INFECTION CONTROL
NOTES
1. ALL AREAS ON THIS PLAN SHALL BE CONSIDERED
CONSTRUCTION TYPE C, LOW RISK GROUP AND
INFECTION CONTROL PRECAUTION CLASS II UNLESS
OTHERWISE NOTED.
CO
NN
EC
TI
NG
CO
RR
ID
OR
CC
7- B-
FAN RM
HAC
11GENERAL
STORAGE
HAC
STORAGE
11-A
STORAGE RM
11-B
EQUIP
RM
12-A
ELECTRICAL
TRANSFORMER RM
13-A
SUBSTATION(POWER) 12KV
EDISON RM
HAC STORAGE
GENERAL
STORAGE
17A
GENERAL
STORAGE
17B
CONNECTING
CORRIDOR
CC7-B-2
GENERAL
STORAGE
FEC
STAIR
TELECOM
CLOSET
GENERAL
STORAGE
20A
STORAGE
12B
EX
1 (TYP)
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Fi le
P at h
U.S. Department of Veterans Affairs
B
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
STAMPCONSULTANT
321 4 5 6 7 8 9 10
Project Director
Revisions: Date:
Key Plan
Electronic Health Records Modernization (EHRM) Infrastructure Upgrades - Long Beach
5901 E. SEVENTH STREET, LONG BEACH, CA 90822
600-20-120
CONTRACT DOCUMENTS
December 16, 2020 JC GB
FULLY SPRINKLERED
NORTH
A
GENERAL NOTES
KEY NOTES
17075 Via Del Campo, San Diego, CA 92127 Phone: 858.946.0333
ARCHITECT/ENGINEER OF RECORD
0' 4' 16' 24'2' 8'SCALE: 3/32" = 1'-0"
C
D
20801.10
ARCHITECTURAL BASEMENT
FLOOR PLAN
ARCHITECTURAL BASEMENT FLOOR PLAN
7.A-101
NORTH
1. REMOVE AND REINSTALL CEILING AS REQUIRED FOR
RUNNING CABLING.
BUILDING 7
F1
DOOR RATING LEGEND
NON-RATED SMOKE- RESISTANT
FIRE DOOR
20-MINUTE RATED FIRE DOOR
45-MINUTE RATED FIRE DOOR
60-MINUTE RATED FIRE DOOR
90-MINUTE RATED FIRE DOOR
90-MINUTE SMOKE- RESISTANT
FIRE DOOR
180-MINUTE RATED FIRE DOOR
RATED DOOR TAG
(XX:BLDG; YY: LEVEL; Z:ID; W:MINUTES)
EX
EXIT STAIR
HAZARDOUS ROOM (NFPA 101 §8.7)
INTERIOR EXIT LOCATION
EXTERIOR EXIT DISCHARGE
WALL TYPE LEGEND
HZ
3-HR. FIRE BARRIER
2-HR. FIRE/SMOKE BARRIER
1-HR. FIRE/SMOKE BARRIER
SMOKE BARRIER
SMOKE PARTITION
INTERIOR EXIT PASSAGEWAY
LIFE SAFETY LEGEND
1. PROVIDE UL LISTED FIRESTOPPING AT ALL
PENETRATIONS OF FIRE RATED WALLS.
2. USE EZ PATH OR SIMILAR TO ALLOW CABLES TO
PENETRATE WALLS, W/O LIMITING ABILITY TO
ADD/REMOVE CABLES AT A LATER TIME W/O RESEALING.
3. COORDINATE RELOCATION OF EXISTING EQUIPMENT
AND FURNITURE WITH THE VA AS INDICATED ON
PROJECT NOTE 5 ON GI001.
INFECTION CONTROL
NOTES
1. ALL AREAS ON THIS PLAN SHALL BE CONSIDERED
CONSTRUCTION TYPE D, LOW RISK GROUP AND
INFECTION CONTROL PRECAUTION CLASS IV UNLESS
OTHERWISE NOTED.
EX
EXEX
EX
EX
EX
HZ
HZ
HZ
MICROBIOLOGY
103B
OFFICE
103A
STORAGE
IMMUNO-HISTOLOGY
CHEMISTRY
GROSSING
WOMENS
TOILET
MENS
TOILET
CASHIER
OFFICE
CORRIDOR
SWING
100B
HOUSE
KEEPING
101 OUT PATIENT
PHARMACY
WAITING AREA
WAITING AREA
ETHICS OFFICE
OF THE DIRECTOR
100A
HAC STORAGE
TRAVEL
OFFICE
STAIR
STAIR
NO 2
101A
105A
C7-1-1
103C
103M
RECVG
103D 103E
103K
BREAK
RM OFFICE
103H 103F 103G
HALL WAY
EMP AREA
HISTOLOGY
1 (TYP)
RISK: HIGH
INFECTION CONTROL PRECAUTION: CLASS IV
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Fi le
P at h
U.S. Department of Veterans Affairs
B
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
STAMPCONSULTANT
321 4 5 6 7 8 9 10
Project Director
Revisions: Date:
Key Plan
Electronic Health Records Modernization (EHRM) Infrastructure Upgrades - Long Beach
5901 E. SEVENTH STREET, LONG BEACH, CA 90822
600-20-120
CONTRACT DOCUMENTS
December 16, 2020 JC GB
FULLY SPRINKLERED
NORTH
A
GENERAL NOTES
KEY NOTES
17075 Via Del Campo, San Diego, CA 92127 Phone: 858.946.0333
ARCHITECT/ENGINEER OF RECORD
0' 4' 16' 24'2' 8'SCALE: 3/32" = 1'-0"
C
D
20801.10
ARCHITECTURAL FIRST FLOOR
PLAN
ARCHITECTURAL FIRST FLOOR PLAN
7.A-111
NORTH
1. REMOVE AND REINSTALL CEILING AS REQUIRED FOR
RUNNING CABLING.
2. SEE TELECOMMUNICATIONS SHEET 7.T-111 FOR FIBER
ROUTING WITHIN WALL. REPAIR EXISTING WALL SURFACE
AND FINISH TO MATCH EXISTING.
BUILDING 7
F1
DOOR RATING LEGEND
NON-RATED SMOKE- RESISTANT
FIRE DOOR
20-MINUTE RATED FIRE DOOR
45-MINUTE RATED FIRE DOOR
60-MINUTE RATED FIRE DOOR
90-MINUTE RATED FIRE DOOR
90-MINUTE SMOKE- RESISTANT
FIRE DOOR
180-MINUTE RATED FIRE DOOR
RATED DOOR TAG
(XX:BLDG; YY: LEVEL; Z:ID; W:MINUTES)
EX
EXIT STAIR
HAZARDOUS ROOM (NFPA 101 §8.7)
INTERIOR EXIT LOCATION
EXTERIOR EXIT DISCHARGE
WALL TYPE LEGEND
HZ
3-HR. FIRE BARRIER
2-HR. FIRE/SMOKE BARRIER
1-HR. FIRE/SMOKE BARRIER
SMOKE BARRIER
SMOKE PARTITION
INTERIOR EXIT PASSAGEWAY
LIFE SAFETY LEGEND
1. PROVIDE UL LISTED FIRESTOPPING AT ALL
PENETRATIONS OF FIRE RATED WALLS.
2. USE EZ PATH OR SIMILAR TO ALLOW CABLES TO
PENETRATE WALLS, W/O LIMITING ABILITY TO
ADD/REMOVE CABLES AT A LATER TIME W/O RESEALING.
3. COORDINATE RELOCATION OF EXISTING EQUIPMENT
AND FURNITURE WITH THE VA AS INDICATED ON
PROJECT NOTE 5 ON GI001.
INFECTION CONTROL
NOTES
1. ALL AREAS ON THIS PLAN SHALL BE CONSIDERED
CONSTRUCTION TYPE D, LOW RISK GROUP AND
INFECTION CONTROL PRECAUTION CLASS IV UNLESS
OTHERWISE NOTED.
CLOSET
ELECTRICAL
ELECTRICAL
SOILED
UTILITIES
FEC
MINOR SURGY
LASER RM
EXAM
RM
223A
CONNECTING
CORRIDOR
CO
NN
EC
TI
NG
CO
RR
ID
OR
HAC
STORAGE
CONFERENCE
RM
TECHS SUPV
OFFICE
200E
BREAK RM
200D
CASE MGR
OFFICE
200C
STORAGE
200B-A
ULTRA
SOUND RM
GENERAL
STORAGE
EX
AM
R M
OFFICE
RECEPTION
WAITING
AREA
EX
AM
R M
4C
EX
AM
R M
4B
V I S T
CO-ORDINATIOR
OFFICE
213A
CLEAN
UTILITIES
OPHTHALMOLOGY
OFFICE
EXAM RM
TELTOILET
209B
CHIEF OFFICE
SECY
214N
EXAM RM
214M
EX
AM
R M
4L
CLINIC
NURSE
214K
EX
AM
R M
4H
EX
AM
R M
4G
EX
AM
R M
4F
EX
AM
R M
4E
FITTING
RM
223C
STAIR
EY
E
E
XA
M
RM
4D
EYE
EXAM
RM
STAIR
NO 2209A
200A
222A
222B
221A
HAC 200BHZ
HZ
HZ HZ HZ EX
EX
007.2.01
007.2.02
007.2.03
1 (TYP)
RISK: MEDIUM
INFECTION CONTROL PRECAUTION: CLASS IV
RISK: MEDIUM
INFECTION CONTROL PRECAUTION: CLASS IV
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Fi le
P at h
U.S. Department of Veterans Affairs
B
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
STAMPCONSULTANT
321 4 5 6 7 8 9 10
Project Director
Revisions: Date:
Key Plan
Electronic Health Records Modernization (EHRM) Infrastructure Upgrades - Long Beach
5901 E. SEVENTH STREET, LONG BEACH, CA 90822
600-20-120
CONTRACT DOCUMENTS
December 16, 2020 JC GB
FULLY SPRINKLERED
NORTH
A
GENERAL NOTES
KEY NOTES
17075 Via Del Campo, San Diego, CA 92127 Phone: 858.946.0333
ARCHITECT/ENGINEER OF RECORD
0' 4' 16' 24'2' 8'SCALE: 3/32" = 1'-0"
C
D
20801.10
ARCHITECTURAL SECOND FLOOR
PLAN
ARCHITECTURAL SECOND FLOOR PLAN
7.A-121
NORTH
1. REMOVE AND REINSTALL CEILING AS REQUIRED FOR
RUNNING CABLING.
BUILDING 7
F1
DOOR RATING LEGEND
NON-RATED SMOKE- RESISTANT
FIRE DOOR
20-MINUTE RATED FIRE DOOR
45-MINUTE RATED FIRE DOOR
60-MINUTE RATED FIRE DOOR
90-MINUTE RATED FIRE DOOR
90-MINUTE SMOKE- RESISTANT
FIRE DOOR
180-MINUTE RATED FIRE DOOR
RATED DOOR TAG
(XX:BLDG; YY: LEVEL; Z:ID; W:MINUTES)
EX
EXIT STAIR
HAZARDOUS ROOM (NFPA 101 §8.7)
INTERIOR EXIT LOCATION
EXTERIOR EXIT DISCHARGE
WALL TYPE LEGEND
HZ
3-HR. FIRE BARRIER
2-HR. FIRE/SMOKE BARRIER
1-HR. FIRE/SMOKE BARRIER
SMOKE BARRIER
SMOKE PARTITION
INTERIOR EXIT PASSAGEWAY
LIFE SAFETY LEGEND
1. PROVIDE UL LISTED FIRESTOPPING AT ALL
PENETRATIONS OF FIRE RATED WALLS.
2. USE EZ PATH OR SIMILAR TO ALLOW CABLES TO
PENETRATE WALLS, W/O LIMITING ABILITY TO
ADD/REMOVE CABLES AT A LATER TIME W/O RESEALING.
3. COORDINATE RELOCATION OF EXISTING EQUIPMENT
AND FURNITURE WITH THE VA AS INDICATED ON
PROJECT NOTE 5 ON GI001.
INFECTION CONTROL
NOTES
1. ALL AREAS ON THIS PLAN SHALL BE CONSIDERED
CONSTRUCTION TYPE D, LOW RISK GROUP AND
INFECTION CONTROL PRECAUTION CLASS IV UNLESS
OTHERWISE NOTED.
WAITING
AREA
EXAM RM
303A
VASCULAR
RESEARCH
303B
EXAM RM
300F
RESEARCH
CO-ORDR
RESEARCH
RM
EXAM RM
ALLERGY/
IMMUNOLOGY CLINIC
EXAM RM
328A
WAITING
AREA
ALLERGY
CLINIC
300A
ALLERGY
CLINIC
300B
ALLERGY
CLINIC
300C
ALLERGY
CLINIC
300D
ALLERGY
LAB
300E
CO
RR
ID
OR
EXAM RM
303C
EXAM RM
ALCOVE
TEL
309OFFICE
310B
OFFICE
310A
HAC RM
OXYGEN
STORAGE
EXAM RM
EXAM RM
ST
OR
AG
E
7A
EXAM RM
RESEARCH
RM
VASCULAR
SURGY
RESEARCH
OFFICE
EXAM RM
ELECTRICAL
MEDICATION
RM
OFFICE
EXAM RM
MENS RM
WOMENS RM
EXAM RM
EXAM RM
EXAM RM
EXAM RM
EXAM RM
EXAM RM
328B
EXAM RM
328D
EXAM
RM
328C
STAIR
STAIR
NO 2
ELECTRICAL PANEL
C7 -3
-1
300C-1
EX
EX
007.3.02
007.3.01
HZ
HZ
HZ
007.3.03
1 (TYP)
RISK: MEDIUM
INFECTION CONTROL PRECAUTION: CLASS IV
RISK: MEDIUM
INFECTION CONTROL PRECAUTION: CLASS IV
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Fi le
P at h
U.S. Department of Veterans Affairs
B
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
STAMPCONSULTANT
321 4 5 6 7 8 9 10
Project Director
Revisions: Date:
Key Plan
Electronic Health Records Modernization (EHRM) Infrastructure Upgrades - Long Beach
5901 E. SEVENTH STREET, LONG BEACH, CA 90822
600-20-120
CONTRACT DOCUMENTS
December 16, 2020 JC GB
FULLY SPRINKLERED
NORTH
A
GENERAL NOTES
KEY NOTES
17075 Via Del Campo, San Diego, CA 92127 Phone: 858.946.0333
ARCHITECT/ENGINEER OF RECORD
0' 4' 16' 24'2' 8'SCALE: 3/32" = 1'-0"
C
D
20801.10
ARCHITECTURAL THIRD FLOOR
PLAN
ARCHITECTURAL THIRD FLOOR PLAN
7.A-131
NORTH
1. REMOVE AND REINSTALL CEILING AS REQUIRED FOR
RUNNING CABLING.
BUILDING 7
F1
DOOR RATING LEGEND
NON-RATED SMOKE- RESISTANT
FIRE DOOR
20-MINUTE RATED FIRE DOOR
45-MINUTE RATED FIRE DOOR
60-MINUTE RATED FIRE DOOR
90-MINUTE RATED FIRE DOOR
90-MINUTE SMOKE- RESISTANT
FIRE DOOR
180-MINUTE RATED FIRE DOOR
RATED DOOR TAG
(XX:BLDG; YY: LEVEL; Z:ID; W:MINUTES)
EX
EXIT STAIR
HAZARDOUS ROOM (NFPA 101 §8.7)
INTERIOR EXIT LOCATION
EXTERIOR EXIT DISCHARGE
WALL TYPE LEGEND
HZ
3-HR. FIRE BARRIER
2-HR. FIRE/SMOKE BARRIER
1-HR. FIRE/SMOKE BARRIER
SMOKE BARRIER
SMOKE PARTITION
INTERIOR EXIT PASSAGEWAY
LIFE SAFETY LEGEND
1. PROVIDE UL LISTED FIRESTOPPING AT ALL
PENETRATIONS OF FIRE RATED WALLS.
2. USE EZ PATH OR SIMILAR TO ALLOW CABLES TO
PENETRATE WALLS, W/O LIMITING ABILITY TO
ADD/REMOVE CABLES AT A LATER TIME W/O
RESEALING.
3. COORDINATE RELOCATION OF EXISTING EQUIPMENT
AND FURNITURE WITH THE VA AS INDICATED ON
PROJECT NOTE 5 ON GI001.
INFECTION CONTROL
NOTES
1. ALL AREAS ON THIS PLAN SHALL BE CONSIDERED
CONSTRUCTION TYPE D, LOW RISK GROUP AND
INFECTION CONTROL PRECAUTION CLASS IV UNLESS
OTHERWISE NOTED.
CO
RR
ID
OR
CC
-B
8-
EQUIP
STORAGE
CORRIDOR
CC-B8-5
CARDIOLOGY
STORAGE
19B
CO
RR
ID
OR
CC
-B
8-
STORAGE
18-004
STAIR
FILTER RM
CO
RR
ID
OR
CC
-B
8-
BOILER
17A
ELECTRICAL VAULT
ELECTRICAL CLOSET
COMPRESSOR
15A
HALLWAY
CC-B8-1
BOILER RM
ENGG
STORAGE
GENERAL
STORAGE
HAC
BUILDING MGMT STORAGE
BUILDING MGMT STORAGE
MED MEDIA STORAGE RM
HALLWAY
MECH RM
EX EX
EX
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Fi le
P at h
U.S. Department of Veterans Affairs
B
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
STAMPCONSULTANT
321 4 5 6 7 8 9 10
Project Director
Revisions: Date:
Key Plan
Electronic Health Records Modernization (EHRM) Infrastructure Upgrades - Long Beach
5901 E. SEVENTH STREET, LONG BEACH, CA 90822
600-20-120
CONTRACT DOCUMENTS
December 16, 2020 JC GB
FULLY SPRINKLERED
NORTH
A
GENERAL NOTES
KEY NOTES
17075 Via Del Campo, San Diego, CA 92127 Phone: 858.946.0333
ARCHITECT/ENGINEER OF RECORD
0' 4' 16' 24'2' 8'SCALE: 3/32" = 1'-0"
C
D
20801.10
ARCHITECTURAL BASEMENT
FLOOR PLAN (FOR REFERENCE
ONLY)
ARCHITECTURAL BASEMENT FLOOR PLAN (FOR REFERENCE ONLY)
8.A-101
NORTH
BUILDING 8
F1
DOOR RATING LEGEND
NON-RATED SMOKE- RESISTANT
FIRE DOOR
20-MINUTE RATED FIRE DOOR
45-MINUTE RATED FIRE DOOR
60-MINUTE RATED FIRE DOOR
90-MINUTE RATED FIRE DOOR
90-MINUTE SMOKE- RESISTANT
FIRE DOOR
180-MINUTE RATED FIRE DOOR
RATED DOOR TAG
(XX:BLDG; YY: LEVEL; Z:ID; W:MINUTES)
EX
EXIT STAIR
HAZARDOUS ROOM (NFPA 101 §8.7)
INTERIOR EXIT LOCATION
EXTERIOR EXIT DISCHARGE
WALL TYPE LEGEND
HZ
3-HR. FIRE BARRIER
2-HR. FIRE/SMOKE BARRIER
1-HR. FIRE/SMOKE BARRIER
SMOKE BARRIER
SMOKE PARTITION
INTERIOR EXIT PASSAGEWAY
LIFE SAFETY LEGEND
ELEC
FEC
117A1
CORRIDOR
CC-8-1
CO
RR
ID
OR
CC
-8
-3
CO
RR
ID
OR
CC
-8 -2
CORRIDOR
CC-8-5
CORRIDOR
CC-8-4
STAIR
NO-2
FILE RM
119A
OCCUPATION HEALTH
NURSE
TRIAGE
EXAM
NU
RS
E
TR
IA
GE
EXAM
TEL
CO
ELEC
CO
AG
EN
T
OF
FI
CE
4MENS
TOILET
WOMENS
TOILET
TEL RM
TEAMLET RM
EXAM
VET SVC
OFFICE
DAV OFFICE
AM VETS
OFFICE
VVA OFFICE
VSO WAITING RM
VSO OFFICE
VSO OFFICE
TRASH AND
LINEN
103HAC
OFFICE
VOLUNTEERS
OFFICE
STAIR
NO 3
100AEX
EX
EX
HZ
HZ
EX
HZ
TELECOM ROOM
RISK: MEDIUM
INFECTION CONTROL PRECAUTION: CLASS IV
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Fi le
P at h
U.S. Department of Veterans Affairs
B
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
STAMPCONSULTANT
321 4 5 6 7 8 9 10
Project Director
Revisions: Date:
Key Plan
Electronic Health Records Modernization (EHRM) Infrastructure Upgrades - Long Beach
5901 E. SEVENTH STREET, LONG BEACH, CA 90822
600-20-120
CONTRACT DOCUMENTS
December 16, 2020 JC GB
FULLY SPRINKLERED
NORTH
A
GENERAL NOTES
KEY NOTES
17075 Via Del Campo, San Diego, CA 92127 Phone: 858.946.0333
ARCHITECT/ENGINEER OF RECORD
0' 4' 16' 24'2' 8'SCALE: 3/32" = 1'-0"
C
D
20801.10
ARCHITECTURAL FIRST FLOOR
PLAN
ARCHITECTURAL FIRST FLOOR PLAN
8.A-111
NORTH
BUILDING 8
F1
E4 A-403
B4 A-403
DOOR RATING LEGEND
NON-RATED SMOKE- RESISTANT
FIRE DOOR
20-MINUTE RATED FIRE DOOR
45-MINUTE RATED FIRE DOOR
60-MINUTE RATED FIRE DOOR
90-MINUTE RATED FIRE DOOR
90-MINUTE SMOKE- RESISTANT
FIRE DOOR
180-MINUTE RATED FIRE DOOR
RATED DOOR TAG
(XX:BLDG; YY: LEVEL; Z:ID; W:MINUTES)
EX
EXIT STAIR
HAZARDOUS ROOM (NFPA 101 §8.7)
INTERIOR EXIT LOCATION
EXTERIOR EXIT DISCHARGE
WALL TYPE LEGEND
HZ
3-HR. FIRE BARRIER
2-HR. FIRE/SMOKE BARRIER
1-HR. FIRE/SMOKE BARRIER
SMOKE BARRIER
SMOKE PARTITION
INTERIOR EXIT PASSAGEWAY
LIFE SAFETY LEGEND
1. BUILDING 8 CONTAINS HAZARDOUS MATERIALS, REFER
TO GI003.
INFECTION CONTROL
NOTES
1. ALL AREAS ON THIS PLAN SHALL BE CONSIDERED
CONSTRUCTION TYPE D, LOW RISK GROUP AND
INFECTION CONTROL PRECAUTION CLASS IV UNLESS
OTHERWISE NOTED.
ELECTRICAL
CO
RR
ID
OR
C8 -3
B
C8-3A
CONNECTING CORRIDOR
C8-3
TRUTH POINT
CO-ORDR
PATIENT
CENTERED CARE
PGM
SPECIALIST
OFFICE
(PATIENT
CENTERED
CARE)
PGM
MGR OFFICE
(PATIENT
CENTERED
CARE)
OFFICE
TEL
COPY RM
MENS
REST RM
WOMENS
REST RM
BREAK
RM
MOBILITY MGR
OFFICE VET
TRANSPORTATION
AND BENEFICIARY
TRAVEL
WARD
ADMIN
AOD (ADMIN
OF THE
DAY)
MED
RECORDS
TECH
OFFICE
NURSING
EDUCATION AND
RESEARCH
STAIROFFICE
(PATIENT
CENTERED
CARE)
223A
MGMT
AND PGM ANALYST
(PATIENT
CENTERED CARE)
OFFICE
OFFICE
OFFICE
OFFICE
TRANSPORTATION
CO-ORDR
OFFICE
MED
RECORDS
TECHNICIAN
OFFICE
RELEASE OF
INFO
(MED
RECORDS)
SUPV (MED
ADMIN
SPECIALIST)
BEREAVEMENT RM
CHIEF (NURSING
EDUCATION AND
RESEARCH) OFFICE
STORAGE
TRASH LINEN
203HAC
OFFICE
OFFICE
200E
OFFICE
200D 200C
OFFICE OF
ACADEMIC
AFFILIATION
200B
OFFICE
200A
OFFICE OF
ACADEMIC
AFFILIATION
CORRIDOR
STAIR
NO 3
ELECTRICAL
CLOSET
220A
220B
220C
200F
CO
RR
ID
OR
NURSING
EDUCATION AND
RESEARCH
EX
HZ
008.2.01
008.2.01
EX
HZ
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date…
This is the start of the file's text. The full file is on GovTribe.