Attachment A2_Drawing 2 of 9.pdf

PDF 28 MB Posted

Attached to
Z2DA--EHRM Long Beach, 600-20-120, Construction Federal contract opportunity
Solicitation number
36C26221B0004
Issued by
Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 22

About this file

This document provides a presolicitation notice for a construction project at the VA Long Beach Healthcare System. The VA will issue an Invitation for Bid on or about April 12, 2021 via beta.SAM.gov for Project 600-20-120 to perform Electronic Health Record Modernization Infrastructure Upgrades at the VA Long Beach Healthcare System located in Long Beach, CA. Work includes general construction, alterations, mechanical and electrical work, utility systems, necessary demolition and removal of existing structures. The project is set aside 100% for Service-Disabled Veteran-Owned Small Businesses and must be listed as verified in Vendor Information Pages. The North American Industry Classification Code is 236220 for Commercial and Institutional Building Construction with a size standard of $39.5 million. The magnitude of the construction project is estimated between $10 million and $20 million. A site visit will be scheduled for prospective bidders.

View the file

Other files for this federal contract opportunity

Show all 23

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

RAMP DN @ 8%

JANITOR'S

CLOSET (HAC)

2N114

SLEEP

TOILET

2N112A

SLEEP

TOILET

2N110A

TOILET, STAFF

2N101

TOILET,

UNISEX

2N105

SLEEP TOILET

2N118A

SLEEP TOILET

2N116A

ALCOVE,

CRASH CART

2N111

SLEEP TOILET

-BARIATRIC

2N121A

STORAGE

ALCOVE,

WHEELCHAIR

2S138

ALCOVE,

CRASH CART

2S128

STORAGE/

MEDICAL

EQUIP

2S118

ELECRICAL RM

2S119

CLEAN LINEN

2S122

2S121

CLEAN LINEN

SLEEP HALL

2N120

SLEEP

STUDY RM

2N112

SLEEP

STUDY RM

2N110

UTILITY RM,

CLEAN

2N109

TELECOM/

DATA RM

2N107

EXAM/PA

OFFICE

2N104

CORRIDOR NORTH

2N100

COPY

RM

2N103

PATIENT

PREP RM

2N122

COORDINATOR

OFFICE

2N124

STORAGE

EQUIP

2N120

SLEEP

STUDY RM

2N118

SLEEP

STUDY RM

2N116

SLEEP

STUDY RM

2N113

SLEEP HALL

2N120

MONITORING RM

ELECTRICAL

2N119

2N117

SLEEP

TOILET

2N113A

SLEEP STUDY RM

-BARIATRIC

2N121

WHEELCHAIR

STORAGE

2N123

RECEPTION

2N125

CONFERENCE RM

2N126

CORRIDOR

SOUTH

2S106

FAMILY

TOILET

2S104

FAMILY

TOILET

2S103

EYEGLASS

REPAIR

2S105

2S105A

PATIENT

EDUCATION/

DISPENSING

WAITING

RM

2S101

PATIENT KIOSK

2S101A

SLEEP LAB WAITING

2S101B

ELEVATOR

LOBBY

2S100

JANITOR'S

CLOSET

(HAC)

2S102

2S149

STAFF

LOCKER

RM

CONFERENCE

RM/

MULTIPURPOSE

2S153

SUPERVISOR

2S154

TOILET,

STAFF

2S150

NURSE

MGR

2S151

WORK

STATIONS

2S155

STAFF HALL

2S152

SECRETARYS

OFFICE

2S159

OPTOMETRY

CHIEF

2S156

ADMIN

OFFICE

2S157

2S158

OPHTHALMOLOGY

CHIEF

EXAM/TREATMENT

OPHTHALMOLOGY

2S135

EXAM/TREATMENT

OPHTHALMOLOGY

2S137

EXAM/TREATMENT

OPHTHALMOLOGY

2S139

EXAM/TREATMENT

OPHTHALMOLOGY

EXAM/TREATMENT

OPHTHALMOLOGY

2S141

2S143

OPHTHALMOLOGY

EXAM

RM/SPECULAR

2S145

OPHTHALMOLOGY

EXAM

RM/AXL

2S147

RECEPTION

2S123

PRE-

TESTING RM

2S125

VISUAL

FIELDS RM

2S134

PRE-

TESTING

RM

2S136 PRE-

TESTING RM

2S127

OPTICAL

COHERENCE

TOMOGRAPHY/

PHOTOGRAPHY

2S142

PRE-

TESTING RM

2S130

SOILED

UTILITY RM

2S131

CLEAN

SUPPLY RM

2S132

LASER

RM

2S144

OFFICE,

EYECARE

PROVIDER

(TEAMLET)

2S146TOILET,

UNISEX

2S148

OPTICAL

COHERENCE

TOMOGRAPHY/

PHOTOGRAPHY

2S116

EXAM/TRAINING RM,

LOW VISION

2S113

EYE

PROCEDURE

RM

2S133

OFFICE, EYECARE

PROVIDER

(TEAMLET)

2S120

PRE-

TESTING

RM

2S111

PRE-

TESTING

RM

2S126

RECEPTION

2S124

VISUAL

FIELDS

RM

2S109

EXAM/TREATMENT

RM,

OPTOMETRY

2S108

EXAM/TREATMENT

RM,

OPTOMETRY

2S110

EXAM/TREATMENT

RM,

OPTOMETRY

2S112

EXAM/TREATMENT

RM,

OPTOMETRY

2S114

EXAM/TRAINING

RM, LOW

VISION

2S117

SECURITY

CLOSET

2S115

EXAM/TRAINING

RM, LOW

VISION

2S119

ELEVATOR

P-6

STAIR

NO 5

ELEVATOR

P-5

SOILED

UTILITY RM

2N108

NURSE

MGR

2N106

EY

E

CL

IN

IC

H

AL

L

2S

STRUCTURED COPPER CABLING HAS BEEN

UPGRADED TO CAT6 AS PART OF 600-402

(SEISMIC UPGRADE PROJECT). BOUNDED AREA

IS NOT IN SCOPE, EXCEPT AS NOTED:

PATHWAYS FOR BUILDING 7 FROM TR(S) THIS

FLOOR.

VA COORDINATION SECOND

FLOOR REFERENCE PLAN

VA COORDINATION SECOND FLOOR REFERENCE PLAN

REF-09

NORTH

126A(OP)

BUILDING 126A(OP)

F1

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Fi le

P at h

U.S. Department of Veterans Affairs

B

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

321 4 5 6 7 8 9 10

Project Director

Key Plan

Electronic Health Records Modernization (EHRM) Infrastructure Upgrades - Long Beach

5901 E. SEVENTH STREET, LONG BEACH, CA 90822

600-20-120

CONTRACT DOCUMENTS

December 16, 2020 JC GB

FULLY SPRINKLERED

NORTH

A

GENERAL NOTES

0' 4' 16' 24'2' 8'0' 8' 16' 32'0' 4' 8' 16'

C

D

1. THE INFORMATION SHOWN HERE IS PROVIDED BY THE VA.

THE SCOPE AND COORDINATION REQUIREMENTS SHOWN

ON THIS SHEET APPLY TO ALL WORK ON THIS PROJECT.

SCALE: 3/32" = 1'-0"

ELEVATOR

MACHINE RM

B-031A

MECH RM

STORAGE

NOURISH

B-028

CART WASHER

AREA

CO

RR

ID

OR

CC

-B

-1

CORRIDOR

CC-B-5

CO

NN

EC

TI

ON

CO

RR

ID

OR

CC

-B -6

CO

RR

ID

OR

CC

-B

-1

ENTRANCE

MED MEDIA

ENTRANCE

MAIL RM

BOILER

CHAMBER

STORAGE

TRASH

COMPACTOR

AREA

TRASH

COMPACTOR WELL

LAB STORAGE

B-037

ELEVATOR

S-10

ELEVATOR

S-9

EMS

SUPV

OFFICE

EMS SUPV

OFFICE

B-034

PHARMACY

STORAGE

B-015

STORAGE

B-016

GENERAL

STORAGE

B-017

B-019B

CHIEFS OFFICE

B-019A

B-019

TELE CLOSET

STAIR

CORRIDOR

C-B-9

ELEVATOR

P-7

ELEVATOR

P-8

WORK SPACE

B-22B

SEC/RECEPT

B-029

PASSENGER

ELEVATOR LOBBY

PHOTO STUDIO

B-021

FINISHING

RM

B-22D

STORAGE

B-22A

COMPUTER

RM

B-22C

OFFICE

B-22E

CLASS RM

B-22F

CO

RR

ID

OR

C- B-

8 CLASS RM

B-23

CONTROL RM

B-23A

GENERAL

STORAGE

B-24

MED/GRAPHICS DESIGN

OFFICE

B-25

GRAPHIC

ARTIST

B-26

EQUIP

CHECKOUT

B-027

MI

CR

OS

CO

PE

RM

B-

7BCHIEF

B-029A

HAC

STORAGE

B-031

GENERAL

STORAGE

B-013

GENERAL

STORAGE

B-012

ENV CARE

SUPV

OFFICE

B-011

RE

CO

RD

MG

MT

OF

FI

CE

B-

9C

BOILER RM

B-014

CO

RR

ID

OR

CC

-B

-1

4 SUPPLY RM

35B

35A

STORAGE

SUPPLY AND

EQUIPMENT

ISSUE

MAIL RM

HAC STORAGE

ELECTRICAL

PANEL

SVC RM ELEVATOR

LOBBY

VE

RY

D

AR

K

RM

B-

7A

B-014A

B-014B

CENTER

EX

EX

EX

EX

EX

EX

EXEX

001.B.01

001.B.02

001.B.03

001.B.04

001.B.05

001.B.06

HZ

HZ

HZ

HZ

HZ

HZ

HZ

HZ

HZ

HZ

HZ

HZ

1 (TYP)

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Fi le

P at h

U.S. Department of Veterans Affairs

B

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

STAMPCONSULTANT

321 4 5 6 7 8 9 10

Project Director

Revisions: Date:

Key Plan

Electronic Health Records Modernization (EHRM) Infrastructure Upgrades - Long Beach

5901 E. SEVENTH STREET, LONG BEACH, CA 90822

600-20-120

CONTRACT DOCUMENTS

December 16, 2020 JC GB

FULLY SPRINKLERED

NORTH

A

GENERAL NOTES

KEY NOTES

17075 Via Del Campo, San Diego, CA 92127 Phone: 858.946.0333

ARCHITECT/ENGINEER OF RECORD

SCALE: 1/8" = 1'-0" 0' 4' 8' 16'

C

D

20801.10

ARCHITECTURAL BASEMENT

FLOOR PLAN

ARCHITECTURAL BASEMENT FLOOR PLAN

1.A-101

NORTH

BUILDING 1

DOOR RATING LEGEND

NON-RATED SMOKE- RESISTANT

FIRE DOOR

20-MINUTE RATED FIRE DOOR

45-MINUTE RATED FIRE DOOR

60-MINUTE RATED FIRE DOOR

90-MINUTE RATED FIRE DOOR

90-MINUTE SMOKE- RESISTANT

FIRE DOOR

180-MINUTE RATED FIRE DOOR

RATED DOOR TAG

(XX:BLDG; YY: LEVEL; Z:ID; W:MINUTES)

EX

EXIT STAIR

HAZARDOUS ROOM (NFPA 101 §8.7)

INTERIOR EXIT LOCATION

EXTERIOR EXIT DISCHARGE

WALL TYPE LEGEND

HZ

3-HR. FIRE BARRIER

2-HR. FIRE/SMOKE BARRIER

1-HR. FIRE/SMOKE BARRIER

SMOKE BARRIER

SMOKE PARTITION

INTERIOR EXIT PASSAGEWAY

LIFE SAFETY LEGEND

1. REMOVE AND REINSTALL CEILING AS REQUIRED FOR

RUNNING CABLING.

F1

1. PROVIDE UL LISTED FIRESTOPPING AT ALL

PENETRATIONS OF FIRE RATED WALLS.

2. USE EZ PATH OR SIMILAR TO ALLOW CABLES TO

PENETRATE WALLS, W/O LIMITING ABILITY TO

ADD/REMOVE CABLES AT A LATER TIME W/O RESEALING.

3. COORDINATE RELOCATION OF EXISTING EQUIPMENT

AND FURNITURE WITH THE VA AS INDICATED ON

PROJECT NOTE 5 ON GI001.

4. BUILDING 1 CONTAINS HAZARDOUS MATERIALS, REFER

TO GI003.

INFECTION CONTROL

NOTES

1. ON THIS PLAN, ALL CORRIDORS ARE CONSTRUCTION

TYPE D, LOW RISK GROUP AND INFECTION CONTROL

CLASS III. WHERE CORRIDOR IS SHOWN WITHIN AREA OF

HIGHER PRECAUTION CLASS, CORRIDOR SHALL MEET

THE MORE STRINGENT REQUIREMENT.

2. ALL OTHER AREAS ON THIS PLAN SHALL BE CONSIDERED

CONSTRUCTION TYPE C, LOW RISK GROUP AND

INFECTION CONTROL PRECAUTION CLASS II UNLESS

OTHERWISE NOTED.

3. REFER TO SHEET GI004 THRU GI007 FOR ASSOCIATED

REQUIREMENTS.

STAFF

WOMEN

112A

MECH

SHAFT

DOC

CONN

CORRIDOR

MC-C6

S101A

STAIR

CORRIDOR

C-1-2

CORRIDOR

C-1-4

CORRIDOR

C-1-5

CORRIDOR

C-1-6

CORRIDOR

C-1-1

W

AI

TI

NG

A

RE

A

MEN REST

RM

N104

HAC

N103

MECH

SHAFT

TELEPHONE

CLOSET

IT

STORAGE

N166

SVC ELEVATOR

LOBBY

ELEVATOR

S-9

ELEVATOR

S-10

NURSE CASE

MGR

S116

NURSE CASE

MGR

116A

NURSE

S117

STAFF LOUNGE

GROUP RM

PSYCH

RN CARE

CO-ORDR OFFICE

118A

MEDICATION

RM

DOC OFFICE

S120

WAITING AREA

S123

NURSE

PSYCH

S122

PSYCH

OFFICE

S124

TELECOM

STAIR

CORRIDOR

C-1-3

ELEVATOR

P-8

ELEVATOR

P-7

PASSENGER

ELEVATOR

ELOBBY

RN CARE

CO-ORDR

S101L

CONFERENCE

RM

S101M

OFFICE

S101K

CASE MGR

OFFICE

S101J

EXAM/

TREATMENT RM

S102G S

PATHOLOGIST

TRAINEE

S102F

STAIR

SPEECH

PATHOLOGIST

OFFICE

S102D

WAITING

S102C

CHIEF

SPEECH

PATHOLOGY

S102B

SPEECH

PATHOLOGIST

S102A

STAFF

PSYCHIATRIST

S101H

OFFICE

S101G

OFFICE

S101F

DOCTORS OFFICE

S101E

NURSE

CASE MGR

OFFICE

S101D

WAITING

AREA

S101

DIABETIC

S101C

ADMIN

NURSE

OFFICE

S101B

HAC

SOCIAL

WORKER

COUPLES

OFFICE

S105

OF

FI

CE

S1

-1EXAM RM

S106

NURSE

PRACTITIONER

S107

STAFF

PSYCHATRIST

S108

STAFF

PSYCHIATRISTS

EXAM RM

S109

OFFICE

S110

HAC

SOCIAL

WORKER

OFFICE

S114

OFFICE

S114A

PRIMARY CARE

NURSE

PRACTITIONER

S113

STAFF

MEN

NO 3

NO 2

FE

SOUND

BOOTH

CLASS RM

FAC

PEER

SUPPORT

OFFICE

S102E

IT

STORAGE

N166B

S123A

CENTERFEC

CORRIDOR

EMS SVC

N166A

C1-3A

SOLARIUM

CORRIDOR

C-1-7

EX

EX

HZ

HZ

HZ

HZHZ

EX

EX

TELECOM ROOM

E1 A-402

B1 A-402

1 (TYP)

RISK: MEDIUM

INFECTION CONTROL PRECAUTION: CLASS III

RISK: HIGH

INFECTION CONTROL PRECAUTION: CLASS III

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Fi le

P at h

U.S. Department of Veterans Affairs

B

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

STAMPCONSULTANT

321 4 5 6 7 8 9 10

Project Director

Revisions: Date:

Key Plan

Electronic Health Records Modernization (EHRM) Infrastructure Upgrades - Long Beach

5901 E. SEVENTH STREET, LONG BEACH, CA 90822

600-20-120

CONTRACT DOCUMENTS

December 16, 2020 JC GB

FULLY SPRINKLERED

NORTH

A

GENERAL NOTES

KEY NOTES

17075 Via Del Campo, San Diego, CA 92127 Phone: 858.946.0333

ARCHITECT/ENGINEER OF RECORD

SCALE: 1/8" = 1'-0" 0' 4' 8' 16'

C

D

20801.10

ARCHITECTURAL FIRST FLOOR

PLAN

ARCHITECTURAL FIRST FLOOR PLAN

1.A-111

NORTH

BUILDING 1

1. REMOVE AND REINSTALL CEILING AS REQUIRED FOR

RUNNING CABLING.

F1

DOOR RATING LEGEND

NON-RATED SMOKE- RESISTANT

FIRE DOOR

20-MINUTE RATED FIRE DOOR

45-MINUTE RATED FIRE DOOR

60-MINUTE RATED FIRE DOOR

90-MINUTE RATED FIRE DOOR

90-MINUTE SMOKE- RESISTANT

FIRE DOOR

180-MINUTE RATED FIRE DOOR

RATED DOOR TAG

(XX:BLDG; YY: LEVEL; Z:ID; W:MINUTES)

EX

EXIT STAIR

HAZARDOUS ROOM (NFPA 101 §8.7)

INTERIOR EXIT LOCATION

EXTERIOR EXIT DISCHARGE

WALL TYPE LEGEND

HZ

3-HR. FIRE BARRIER

2-HR. FIRE/SMOKE BARRIER

1-HR. FIRE/SMOKE BARRIER

SMOKE BARRIER

SMOKE PARTITION

INTERIOR EXIT PASSAGEWAY

LIFE SAFETY LEGEND

1. PROVIDE UL LISTED FIRESTOPPING AT ALL

PENETRATIONS OF FIRE RATED WALLS.

2. USE EZ PATH OR SIMILAR TO ALLOW CABLES TO

PENETRATE WALLS, W/O LIMITING ABILITY TO

ADD/REMOVE CABLES AT A LATER TIME W/O RESEALING.

3. COORDINATE RELOCATION OF EXISTING EQUIPMENT

AND FURNITURE WITH THE VA AS INDICATED ON

PROJECT NOTE 5 ON GI001.

4. BUILDING 1 CONTAINS HAZARDOUS MATERIALS, REFER

TO GI003.

INFECTION CONTROL

NOTES

1. ON THIS PLAN, ALL CORRIDORS ARE CONSTRUCTION

TYPE D, LOW RISK GROUP AND INFECTION CONTROL

CLASS III. WHERE CORRIDOR IS SHOWN WITHIN AREA OF

HIGHER PRECAUTION CLASS, CORRIDOR SHALL MEET

THE MORE STRINGENT REQUIREMENT.

2. ALL OTHER AREAS ON THIS PLAN SHALL BE CONSIDERED

CONSTRUCTION TYPE C, LOW RISK GROUP AND

INFECTION CONTROL PRECAUTION CLASS II UNLESS

OTHERWISE NOTED.

FEC

PH

AR

MA

CY

VE

ND

OR

CLOSET

200X

EP

200J

ST

OR

AG

E

0W

0V

CORRIDOR

C2-5

CO

RR

ID

OR

C2 -4

VISUAL INFO

SPECIALIST

OFFICE

CORRIDOR

C2-3

STUDENT

CO-ORDR OFFICE

NURSE

OFFICE

INPATIENT

CLINICAL

PHARMACY

RESIDENT

218B

INPATIENT

CLINICAL SUP

RESIDENCY

PROG DIR

218A

STERILE

PROCESSING

ELEVATOR

S-10

ELEVATOR

S-9

MECH

SHAFT

CO

RR

ID

OR

STORAGE

232A

HAC

GENERAL

STORAGE

PHARMACY

AND CLINICAL

SUPPORT

SVCS

BUSINESS

MGR OFFICE

ADMIN ASST

OFFICE

PRAYER AND

MEDITATION RM

NUTRITION

OFFICE

225A

MEN TOILET

FAC

INFORMATICS

PHARMACIST

WOMEN

TIOLET

HAC

CLOSET

CORRIDOR

C2-1

PASSENGER

ELEVATOR

LOBBY

EL

EV

AT

OR

P-

EL

EV

AT

OR

P-

CORRIDOR

C2-6

CORRIDOR

C2-8

CO

RR

ID

OR

C2 -7

QA/QC COORD

OFFICE

200A

LAB / OPERATIONS

MGR OFFICE

200B

SUPPLY

TECHNICIAN

OFFICE

200C

CO

NN

EC

TI

ON

CO

RR

ID

OR

MC

-C

CO

RR

ID

OR

C2 -2

ELECTRIC

CLOSET

CL

OS

ET

2A

RED CROSS

VOLUNTEERS

BREAK RM

223A

STAIR

NO 3

PHARMACY/ CONFERENCE

BREAKROOM

223PHARMACIST

OFFICE

219C

RESEARCH

ASST

OFFICE

219BPHARMA

ECONOMIC

FORMULARY

MGMT DRUG INFO

OFFICE

219E

ASST CHIEF

SUPPORT SVCS

OFFICE

219G

PHARMACY

ADMINISTRATIVE

OFFICE

COPY

219H

CONFERENCE RM

CORRIDOR

C2-10

ACTING

CHIEF OF

PATHOLOGY

200Z

STAIR

PGM SUPPORT

OFFICE

200Y

CONFERENCE

RM

200U

CO

RR

ID

OR

C2 -1

PATHOLOGIST

OFFICE

200T

PATHOLOGIST

OFFICE

200S

NURSING OFFICER

OF THE DAY (NOD)

OFFICE

ST

OR

AG

E

3MECH

SHAFT

CHIEF OF

PATHOLOGY

OFFICE

200D

CLOSET

200G

SECY

OFFICE

200E

MULTI-HEADED

MICROSCOPE RM

200H

COPY/ BREAK RM

200F

PATHOLOGY

RESIDENTS

AREA

200K

PATHOLOGY

TRANSCRIPTION

RECORD RM

200L

MI

CR

OS

CO

PE

RM 20

0M

PATHOLOGIST

OFFICE

200N

PATHOLOGIST

OFFICE

200P

PATHOLOGIST

OFFICE

200Q

PATHOLOGIST

OFFICE

200R

STAIR

NO 2

EQ

UI

PM

EN

T

ST

OR

AG

E

ALCOVE

219F

FAC

STORAGE

201P

202P

3P

CENTER

OFFICE

SVC ELEVATOR LOBBY

203A

HZ

HZ

HZ

HZ

HZ

HZ

EX

EX

EX

EX

EX

001.2.01

001.2.02

001.2.03

001.2.04

001.2.05

001.2.06

001.2.07

CORRIDOR

C2-12

1 (TYP)

RISK: HIGH

INFECTION CONTROL PRECAUTION: CLASS III/IV

RISK: HIGH

INFECTION CONTROL PRECAUTION: CLASS III/IV

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Fi le

P at h

U.S. Department of Veterans Affairs

B

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

STAMPCONSULTANT

321 4 5 6 7 8 9 10

Project Director

Revisions: Date:

Key Plan

Electronic Health Records Modernization (EHRM) Infrastructure Upgrades - Long Beach

5901 E. SEVENTH STREET, LONG BEACH, CA 90822

600-20-120

CONTRACT DOCUMENTS

December 16, 2020 JC GB

FULLY SPRINKLERED

NORTH

A

GENERAL NOTES

KEY NOTES

17075 Via Del Campo, San Diego, CA 92127 Phone: 858.946.0333

ARCHITECT/ENGINEER OF RECORD

SCALE: 1/8" = 1'-0" 0' 4' 8' 16'

C

D

20801.10

ARCHITECTURAL SECOND FLOOR

PLAN

ARCHITECTURAL SECOND FLOOR PLAN

1.A-121

NORTH

BUILDING 1

F1

DOOR RATING LEGEND

NON-RATED SMOKE- RESISTANT

FIRE DOOR

20-MINUTE RATED FIRE DOOR

45-MINUTE RATED FIRE DOOR

60-MINUTE RATED FIRE DOOR

90-MINUTE RATED FIRE DOOR

90-MINUTE SMOKE- RESISTANT

FIRE DOOR

180-MINUTE RATED FIRE DOOR

RATED DOOR TAG

(XX:BLDG; YY: LEVEL; Z:ID; W:MINUTES)

EX

EXIT STAIR

HAZARDOUS ROOM (NFPA 101 §8.7)

INTERIOR EXIT LOCATION

EXTERIOR EXIT DISCHARGE

WALL TYPE LEGEND

HZ

3-HR. FIRE BARRIER

2-HR. FIRE/SMOKE BARRIER

1-HR. FIRE/SMOKE BARRIER

SMOKE BARRIER

SMOKE PARTITION

INTERIOR EXIT PASSAGEWAY

LIFE SAFETY LEGEND

1. REMOVE AND REINSTALL CEILING AS REQUIRED FOR

RUNNING CABLING.

1. PROVIDE UL LISTED FIRESTOPPING AT ALL

PENETRATIONS OF FIRE RATED WALLS.

2. USE EZ PATH OR SIMILAR TO ALLOW CABLES TO

PENETRATE WALLS, W/O LIMITING ABILITY TO

ADD/REMOVE CABLES AT A LATER TIME W/O RESEALING.

3. COORDINATE RELOCATION OF EXISTING EQUIPMENT

AND FURNITURE WITH THE VA AS INDICATED ON

PROJECT NOTE 5 ON GI001.

4. BUILDING 1 CONTAINS HAZARDOUS MATERIALS, REFER

TO GI003.

INFECTION CONTROL

NOTES

1. ON THIS PLAN, ALL CORRIDORS ARE CONSTRUCTION

TYPE D, LOW RISK GROUP AND INFECTION CONTROL

CLASS III. WHERE CORRIDOR IS SHOWN WITHIN AREA OF

HIGHER PRECAUTION CLASS, CORRIDOR SHALL MEET

THE MORE STRINGENT REQUIREMENT.

2. ALL OTHER AREAS ON THIS PLAN SHALL BE CONSIDERED

CONSTRUCTION TYPE C, LOW RISK GROUP AND

INFECTION CONTROL PRECAUTION CLASS II UNLESS

OTHERWISE NOTED.

HZ

HZ

HZ

HZ

HZ

HZ

HZ

HZ

HZ

HZ

EX

EX

EX

EX

EX

VESTIBULE

316A

FEMALE TOILET

ELECTRICAL

CLOSET

309A

TOILET

RM

327B

TELE-COMM

CLOSET

315A

302F

DRESSING

RM

323A

LOCKER

327A

CORRIDOR

CORRIDOR

C3-2

CO

RR

ID

OR

C3 -5

CO

RR

ID

OR

C3 -5

A

CORRIDOR

C3-3

CORRIDOR

C3-4

CORRIDOR

C3-4A

STERILE SUPPLY RM

322B

CO

NN

EC

TI

NG

CO

RR

ID

OR

MC

-C

ELEVATOR LOBBY

TOILET

(LIBRARY)

BREAK RM

335C

EL

EV

AT

OR

EL

EV

AT

OR

LIBRARY

STORAGE

335B

LIBRARY

OFFICE

LIBRARY

OFFICE

335A

MALE

TOILET

PASSENGER

ELEVATOR

LOBBY

301D

ORTHO NURSES

OFFICE

301A

ORTHO

STORAGE

301B

ELECTRICAL

RM

301E

ORTHO

WAITING

AREA

301C

ORTHO

RECEPTION

AREA

ORTHO

PHYSICIAN

OFFICE

EQUIPMENT

STORAGE

ORTHO

CHIEFS

OFFICE

OR

TH

O

SE

CR

EA

TA

RY

OF

FI

CE

5 ORTHO

LIBRARY RM

STAIR

ORTHO

CONFERENCE

RM

ORTHO

EXAM RM

307A

ORTHO

EXAM RM

ORTHO

EXAM RM

308A

ORTHO

EXAM RM

ORTHO

CAST RM

ORTHO

STORAGE

310A

ORTHO

CAST RM

310B

ORTHO DR

OFFICE

TELEPHONE

CLOSET

CASE MGR

OFFICE

CATH LAB

WAITING RM

CATH

LAB

OFFICE

314AASST CHIEF

CARDIAC CRITICAL

CARE UNIT

OFFICE

CHIEF CARDIAC

CATH LAB

319A

WORK

STATION

ASST CHIEF

CARDIAC

319B

SOILED

UTILITY

320CONTROL RM

CARDIAC

CATH LAB

EQUIP

RM

322A

STAIR

ELEVATOR

ELEVATOR

ELECTRICAL

VAULT RM

TELE RM

STAIR

BREAK RM

EQUIPMENT

STORAGE

326A

CONFERENCE RM

COPIER

RM

OFFICE

OFFICE

324A

ENTRANCE

REST

ROOM

323D

HAC

323C

CH

IE

F

CA

RD

IO

LO

GY

OF

FI

CE

3B

NO 2

NO 3

P-8

P-7

S-

S-

ALCOVE

323E

TEL

FAC

TELE-COMM

FEC

325A

CENTER

SHAFT

CO

RR

ID

OR

C3 -6

A

CORRIDOR

C3-6

SHAFT

1 (TYP)

D6 A-401

D1 A-401

TELECOM ROOM

RISK: HIGHEST

INFECTION CONTROL PRECAUTION: CLASS IV

RISK: MEDIUM

INFECTION CONTROL PRECAUTION: CLASS III

RISK: LOW

INFECTION CONTROL PRECAUTION: CLASS III

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Fi le

P at h

U.S. Department of Veterans Affairs

B

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

STAMPCONSULTANT

321 4 5 6 7 8 9 10

Project Director

Revisions: Date:

Key Plan

Electronic Health Records Modernization (EHRM) Infrastructure Upgrades - Long Beach

5901 E. SEVENTH STREET, LONG BEACH, CA 90822

600-20-120

CONTRACT DOCUMENTS

December 16, 2020 JC GB

FULLY SPRINKLERED

NORTH

A

GENERAL NOTES

KEY NOTES

17075 Via Del Campo, San Diego, CA 92127 Phone: 858.946.0333

ARCHITECT/ENGINEER OF RECORD

SCALE: 1/8" = 1'-0" 0' 4' 8' 16'

C

D

20801.10

ARCHITECTUAL THIRD FLOOR PLAN

ARCHITECTUAL THIRD FLOOR PLAN

1.A-131

NORTH

1. REMOVE AND REINSTALL CEILING AS REQUIRED FOR

RUNNING CABLING.

BUILDING 1

F1

DOOR RATING LEGEND

NON-RATED SMOKE- RESISTANT

FIRE DOOR

20-MINUTE RATED FIRE DOOR

45-MINUTE RATED FIRE DOOR

60-MINUTE RATED FIRE DOOR

90-MINUTE RATED FIRE DOOR

90-MINUTE SMOKE- RESISTANT

FIRE DOOR

180-MINUTE RATED FIRE DOOR

RATED DOOR TAG

(XX:BLDG; YY: LEVEL; Z:ID; W:MINUTES)

EX

EXIT STAIR

HAZARDOUS ROOM (NFPA 101 §8.7)

INTERIOR EXIT LOCATION

EXTERIOR EXIT DISCHARGE

WALL TYPE LEGEND

HZ

3-HR. FIRE BARRIER

2-HR. FIRE/SMOKE BARRIER

1-HR. FIRE/SMOKE BARRIER

SMOKE BARRIER

SMOKE PARTITION

INTERIOR EXIT PASSAGEWAY

LIFE SAFETY LEGEND

1. PROVIDE UL LISTED FIRESTOPPING AT ALL

PENETRATIONS OF FIRE RATED WALLS.

2. USE EZ PATH OR SIMILAR TO ALLOW CABLES TO

PENETRATE WALLS, W/O LIMITING ABILITY TO

ADD/REMOVE CABLES AT A LATER TIME W/O RESEALING.

3. COORDINATE RELOCATION OF EXISTING EQUIPMENT

AND FURNITURE WITH THE VA AS INDICATED ON

PROJECT NOTE 5 ON GI001.

4. BUILDING 1 CONTAINS HAZARDOUS MATERIALS, REFER

TO GI003.

INFECTION CONTROL

NOTES

1. ON THIS PLAN, ALL CORRIDORS ARE CONSTRUCTION

TYPE D, LOW RISK GROUP AND INFECTION CONTROL

CLASS III. WHERE CORRIDOR IS SHOWN WITHIN AREA OF

HIGHER PRECAUTION CLASS, CORRIDOR SHALL MEET

THE MORE STRINGENT REQUIREMENT.

2. ALL OTHER AREAS ON THIS PLAN SHALL BE CONSIDERED

CONSTRUCTION TYPE C, LOW RISK GROUP AND

INFECTION CONTROL PRECAUTION CLASS II UNLESS

OTHERWISE NOTED.

MENS

TOILET

WOMENS

TOILET

ELECTRIC

CLOSET

EEO MGR

CORRIDOR

C4-4

SMALL CONF

RM

ST

OR

AG

E

RM 42

MECH HVAC RM

CORRIDOR

C4-1

SVC ELEVATOR

LOBBY

PASSENGER

ELEVATOR

LOBBY

CORRIDOR

C4-2

ADMIN

PRIMARY CARE

OFFICE

STAIR

EL

EV

AT

OR

S-

EL

EV

AT

OR

S-

BREAK RM

403A

COMPLIANCE

OFFICE

FI

LE

S

TO

RA

GE

R M

ELEVATOR

P-7

ELEVATOR

P-8

MEDICINE

OFFICE

402 RESTROOM

EEO

RECORDS

SECY

OFFICE

OFFICE RM

423A

MECH

SHAFT

OFFICE RM

CONFERENCE

RM

419B

CHIEF OF

PATIENT

CARE SVCS

CHIEF

OF

MEDICINE

PUBLIC

RELATIONS

AD

MI

NI

ST

RA

TI

VE

OF

FI

CE

FAC

DIRECTOR OF

PUBLIC

AFFAIRS

OFFICE

REGIONAL

COUNCIL

ADMIN

OFFICER

CHIEF OF

STAFF

CONFERENCE

409A EEO

OFFICE

409B

OFFICE RM

OFFICE RM

OFFICE RM

OFFICE RM

FAC

NO-3

STAIR

NO-2

STAIR

EC

OFFICE RM

OFFICE RM

OFFICE RM

OFFICE RM

OFFICE RM

CHIEF OFFICE RM

OFFICE RM

445A

OFFICE RM

OFFICE RM

OFFICE RM

OFFICE RM

OFFICE RM

OFFICE RM

OFFICE RM

BREAK RM

ST

OR

AG

E

RM 42

OFFICE RM

OFFICE RM

CORRIDOR

C4-7

CORRIDOR

C4-5

CO

RR

ID

OR

C4 -9

CORRIDOR

C4-6

432A

CENTER

COPY

CORRIDOR

HZ

HZ

HZ

HZ

HZ

EX

EX

EX1 (TYP)

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Fi le

P at h

U.S. Department of Veterans Affairs

B

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

STAMPCONSULTANT

321 4 5 6 7 8 9 10

Project Director

Revisions: Date:

Key Plan

Electronic Health Records Modernization (EHRM) Infrastructure Upgrades - Long Beach

5901 E. SEVENTH STREET, LONG BEACH, CA 90822

600-20-120

CONTRACT DOCUMENTS

December 16, 2020 JC GB

FULLY SPRINKLERED

NORTH

A

GENERAL NOTES

KEY NOTES

17075 Via Del Campo, San Diego, CA 92127 Phone: 858.946.0333

ARCHITECT/ENGINEER OF RECORD

SCALE: 1/8" = 1'-0" 0' 4' 8' 16'

C

D

20801.10

ARCHITECTURAL FOURTH FLOOR

PLAN

ARCHITECTURAL FOURTH FLOOR PLAN

1.A-141

NORTH

BUILDING 1

1. REMOVE AND REINSTALL CEILING AS REQUIRED FOR

RUNNING CABLING.

F1

DOOR RATING LEGEND

NON-RATED SMOKE- RESISTANT

FIRE DOOR

20-MINUTE RATED FIRE DOOR

45-MINUTE RATED FIRE DOOR

60-MINUTE RATED FIRE DOOR

90-MINUTE RATED FIRE DOOR

90-MINUTE SMOKE- RESISTANT

FIRE DOOR

180-MINUTE RATED FIRE DOOR

RATED DOOR TAG

(XX:BLDG; YY: LEVEL; Z:ID; W:MINUTES)

EX

EXIT STAIR

HAZARDOUS ROOM (NFPA 101 §8.7)

INTERIOR EXIT LOCATION

EXTERIOR EXIT DISCHARGE

WALL TYPE LEGEND

HZ

3-HR. FIRE BARRIER

2-HR. FIRE/SMOKE BARRIER

1-HR. FIRE/SMOKE BARRIER

SMOKE BARRIER

SMOKE PARTITION

INTERIOR EXIT PASSAGEWAY

LIFE SAFETY LEGEND

1. PROVIDE UL LISTED FIRESTOPPING AT ALL

PENETRATIONS OF FIRE RATED WALLS.

2. USE EZ PATH OR SIMILAR TO ALLOW CABLES TO

PENETRATE WALLS, W/O LIMITING ABILITY TO

ADD/REMOVE CABLES AT A LATER TIME W/O RESEALING.

3. COORDINATE RELOCATION OF EXISTING EQUIPMENT

AND FURNITURE WITH THE VA AS INDICATED ON

PROJECT NOTE 5 ON GI001.

4. BUILDING 1 CONTAINS HAZARDOUS MATERIALS, REFER

TO GI003.

INFECTION CONTROL

NOTES

1. ON THIS PLAN, ALL CORRIDORS ARE CONSTRUCTION

TYPE D, LOW RISK GROUP AND INFECTION CONTROL

CLASS III. WHERE CORRIDOR IS SHOWN WITHIN AREA OF

HIGHER PRECAUTION CLASS, CORRIDOR SHALL MEET

THE MORE STRINGENT REQUIREMENT.

2. ALL OTHER AREAS ON THIS PLAN SHALL BE CONSIDERED

CONSTRUCTION TYPE C, LOW RISK GROUP AND

INFECTION CONTROL PRECAUTION CLASS II UNLESS

OTHERWISE NOTED.

501A

504C

P-8

P-7

0A

STORAGE

CL

OS

ET

STORAGE

FAC

SVC

ELEVATORS

MECH RM

KITCHENETTE

ELEVATOR

LOBBY

PASSENGER

TOILET

STAIRWELL

ELEVATOR

ELEVATOR

OFFICE OF DATA

COLLECTION

MANAGEMENT

(OCDA)

ME

CH

R M

EX

001.5.01

1 (TYP)

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Fi le

P at h

U.S. Department of Veterans Affairs

B

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

STAMPCONSULTANT

321 4 5 6 7 8 9 10

Project Director

Revisions: Date:

Key Plan

Electronic Health Records Modernization (EHRM) Infrastructure Upgrades - Long Beach

5901 E. SEVENTH STREET, LONG BEACH, CA 90822

600-20-120

CONTRACT DOCUMENTS

December 16, 2020 JC GB

FULLY SPRINKLERED

NORTH

A

GENERAL NOTES

KEY NOTES

17075 Via Del Campo, San Diego, CA 92127 Phone: 858.946.0333

ARCHITECT/ENGINEER OF RECORD

SCALE: 1/8" = 1'-0" 0' 4' 8' 16'

C

D

20801.10

ARCHITECTURAL FIFTH FLOOR

PLAN

ARCHITECTURAL FIFTH FLOOR PLAN

1.A-151

NORTH

BUILDING 1

1. REMOVE AND REINSTALL CEILING AS REQUIRED FOR

RUNNING CABLING.

F1

DOOR RATING LEGEND

NON-RATED SMOKE- RESISTANT

FIRE DOOR

20-MINUTE RATED FIRE DOOR

45-MINUTE RATED FIRE DOOR

60-MINUTE RATED FIRE DOOR

90-MINUTE RATED FIRE DOOR

90-MINUTE SMOKE- RESISTANT

FIRE DOOR

180-MINUTE RATED FIRE DOOR

RATED DOOR TAG

(XX:BLDG; YY: LEVEL; Z:ID; W:MINUTES)

EX

EXIT STAIR

HAZARDOUS ROOM (NFPA 101 §8.7)

INTERIOR EXIT LOCATION

EXTERIOR EXIT DISCHARGE

WALL TYPE LEGEND

HZ

3-HR. FIRE BARRIER

2-HR. FIRE/SMOKE BARRIER

1-HR. FIRE/SMOKE BARRIER

SMOKE BARRIER

SMOKE PARTITION

INTERIOR EXIT PASSAGEWAY

LIFE SAFETY LEGEND

1. PROVIDE UL LISTED FIRESTOPPING AT ALL

PENETRATIONS OF FIRE RATED WALLS.

2. USE EZ PATH OR SIMILAR TO ALLOW CABLES TO

PENETRATE WALLS, W/O LIMITING ABILITY TO

ADD/REMOVE CABLES AT A LATER TIME W/O RESEALING.

3. COORDINATE RELOCATION OF EXISTING EQUIPMENT

AND FURNITURE WITH THE VA AS INDICATED ON

PROJECT NOTE 5 ON GI001.

4. BUILDING 1 CONTAINS HAZARDOUS MATERIALS, REFER

TO GI003.

INFECTION CONTROL

NOTES

1. ALL AREAS ON THIS PLAN SHALL BE CONSIDERED

CONSTRUCTION TYPE C, LOW RISK GROUP AND

INFECTION CONTROL PRECAUTION CLASS II UNLESS

OTHERWISE NOTED.

2. REFER TO SHEET GI004 THRU GI007 FOR ASSOCIATED

FEMALE

EL

EC

TR

IC

AL

RM

AUTOPSY RM

AUTOPSY RM

EQUIPMENT

STORAGE

FILE

STORAGE

CO

RR

ID

OR

CC

2-

B1

CO

RR

ID

OR

CC

2- B1

ELECTRICAL VAULT

TRANSFORMER

52A

ELECTRICAL RM

CORRIDOR

CC2-B4

S P D STORAGE AREA

ENVIRONMENTAL

STORAGE

EMPLOYEE BREAK RM

MALE TOILET

CORRIDOR

CC2-B5

TEMP STORAGE FOR

TELEHEALTH

STORAGE

(ELECTRICAL TV)

38A

IR

M

RM

(E

LE

CT

RI

CA

L T V)

ENTRANCE

MORGUE

37A

CORRIDOR

CC-2-BM1

MALE TOILET

HAC RM

MORGUE

OFFICE

FEMALE

TOILET

REFRIGERATED RM

ELECTRICAL RM

42A

SPECIMEN

STORAGE

46A

AUTOPSY RM

REPRODUCTION

AREA

49FAN RM

48-A

CORRIDOR

CC2-B2

UNIFORM ISSUE AND

CENTRAL LINEN RM

FAN RM

UN

IF

OR

M

RM 50

-H

UN

IF

OR

M

RM 50

-I

LAUNDRY AREA

WASHER EXTRACTOR

50-K

LAUNDRY AREA DRY

AND PRESSING RM

50-J

CORRIDOR

CC2-B3

CANTEEN

STORAGE

50-A

ELECTRICAL

CLOSET

50-L

TEXTILE

CARE

SUPERVISOR

OFFICE

50-G

OFFICE

50-F

EMPL

LOUNGE

50-E

SEWING AND

SCRUB RM

50-CST

OR

AG

E

-C

C

ST

OR

AG

E

-B

BSTORAGE

50-B

SHAFT

SHAFT

HOT WATER TANKS/

PUMP AREA

BED SHOP

UNIFORM

PACKING RM

STAIR

FEMALE TOILET

FEMALE LOCKER

48-A

ANTE RM

49-A

50-D

56B

MALE LOCKER

56A

HAC

50-AA

C

52B

EX EX

EX

HZ

HZ HZ HZ

HZ

HZ

HZ

HZ

HZ

HZ

HZ

HZ

HZ

HZ

HZ

HZ

HZ

HZ

002.B.01

002.B.02

002.B.03

1 (TYP)

RISK: HIGH

INFECTION CONTROL PRECAUTION: CLASS IV

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Fi le

P at h

U.S. Department of Veterans Affairs

B

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

STAMPCONSULTANT

321 4 5 6 7 8 9 10

Project Director

Revisions: Date:

Key Plan

Electronic Health Records Modernization (EHRM) Infrastructure Upgrades - Long Beach

5901 E. SEVENTH STREET, LONG BEACH, CA 90822

600-20-120

CONTRACT DOCUMENTS

December 16, 2020 JC GB

FULLY SPRINKLERED

NORTH

A

GENERAL NOTES

KEY NOTES

17075 Via Del Campo, San Diego, CA 92127 Phone: 858.946.0333

ARCHITECT/ENGINEER OF RECORD

0' 4' 16' 24'2' 8'SCALE: 3/32" = 1'-0"

C

D

20801.10

ARCHITECTURAL BASEMENT

FLOOR PLAN

ARCHITECTURAL BASEMENT FLOOR PLAN

2.A-101

NORTH

1. REMOVE AND REINSTALL CEILING AS REQUIRED FOR

RUNNING CABLING.

2. EUD'S AND CABLES TO REMAIN. SEE REF-01.

BUILDING 2

F1

DOOR RATING LEGEND

NON-RATED SMOKE- RESISTANT

FIRE DOOR

20-MINUTE RATED FIRE DOOR

45-MINUTE RATED FIRE DOOR

60-MINUTE RATED FIRE DOOR

90-MINUTE RATED FIRE DOOR

90-MINUTE SMOKE- RESISTANT

FIRE DOOR

180-MINUTE RATED FIRE DOOR

RATED DOOR TAG

(XX:BLDG; YY: LEVEL; Z:ID; W:MINUTES)

EX

EXIT STAIR

HAZARDOUS ROOM (NFPA 101 §8.7)

INTERIOR EXIT LOCATION

EXTERIOR EXIT DISCHARGE

WALL TYPE LEGEND

HZ

3-HR. FIRE BARRIER

2-HR. FIRE/SMOKE BARRIER

1-HR. FIRE/SMOKE BARRIER

SMOKE BARRIER

SMOKE PARTITION

INTERIOR EXIT PASSAGEWAY

LIFE SAFETY LEGEND

1. PROVIDE UL LISTED FIRESTOPPING AT ALL

PENETRATIONS OF FIRE RATED WALLS.

2. USE EZ PATH OR SIMILAR TO ALLOW CABLES TO

PENETRATE WALLS, W/O LIMITING ABILITY TO

ADD/REMOVE CABLES AT A LATER TIME W/O RESEALING.

3. COORDINATE RELOCATION OF EXISTING EQUIPMENT

AND FURNITURE WITH THE VA AS INDICATED ON

PROJECT NOTE 5 ON GI001.

4. BUILDING 2 CONTAINS HAZARDOUS MATERIALS, REFER

TO GI003.

INFECTION CONTROL

NOTES

1. ALL AREAS ON THIS PLAN SHALL BE CONSIDERED

CONSTRUCTION TYPE D, LOW RISK GROUP AND

INFECTION CONTROL PRECAUTION CLASS IV UNLESS

OTHERWISE NOTED.

TELECOM ROOM IN SCOPE

EL

EC

TR

IC

AL

BREAK RM

PHARMACY CACHE

EMPLOYEE WELLNESS CENTER

WAREHOUSE

STORAGE

121E

WAREHOUSE

STORAGE

EQUIPMENT STORAGE

CALL CENTER PRIMARY

CARE

108A

EXAM RM

N-122A

CO

RR

ID

OR

CC

2-

1-

SOUND

BOOTH

SOUND

RM 2

N-158C

SOUND

RM1

N-158D

SO

UN

D

RM

N-

0A

FAC

OFFICE

N-161

RECEPTION

N-159A

LAB

N-163

OFFICE

N-164CONFERENCE

RM

N-159

OFFICE

N-165

TELECLOSET

NC1-1A

WOMENS

RESTROOM

N-156

SOUND

BOOTH

N-157

VESTIBULE

OFFICE

CHIEF

AUDITORY

RESEARCH

N-157C

OFFICE

N-157B

OFFICE

N-157A

SOUND

RM 4

N-158A

SOUND

RM 3

N-158B

VAULT

EXAM RM

N-122B

GE

NE

RA

L

ST

OR

AG

E

N-

2C

OFFICE

N-122D

FAC

SOUND

BOOTH

RESIDENT

OFFICE

N-119

WORK RM

ENT

ATTENDING

ENT RM

N-118

WAITING AREA

N-126

RECEPTION

AREA

N-125

SOILED

UTILITY

N-124

CLEAN

UTILITY

N-123

PROCEDURE

RM

N-122

FEMALE

TOILET

N-120

MALE

TOILET

N-121

FE

MA

LE

RE

ST

RO

OM

N-

CLINIC

NURSE

CO-ORDR

OFFICE

N-106

EXAM RM 1

N-107

EXAM RM 2

N-108EXAM

RM 3

N-109

EXAM

RM 4

N-110

EQ

UI

PM

EN

T

ST

OR

AG

E N-

EXAM RM 5

EXAM RM 6

N-113

EXAM RM 7

N-114

OFFICE

N-115

SECY

OTOLARYNGOLOGY

CLINIC

N-116

CONFERENCE RM

N-117

CREDIT UNION

CANTEEN

BARBER

SHOP

TRANSFER CO-ORDER

FIT OFFICE

118A

OFFICE

E104

RECEPTION

MALE TOILET

E103

FEMALE TOILET

E102

TOILET

SOUND

RM

CORRIDOR

N-122

FIRE

APPARATUS

CORRIDOR

PHARMACY

OFFICE

CREDIT UNION

CORRIDORN-112

E101

166A166B

STORAGE

N-137

CONTROL

RM

N-160

TRASH

10A

CO

RR

ID

OR

CC

2-

1-

FCC

FCC

CORRIDOR

CC2-1-3

CORRIDOR CC2-1-6

CORRIDOR

CC2-1-5

STORAGE

WAITING

AREA

CASHIER

OFFICE

HZ

HZ HZ

HZ

HZ

EX

EX

EX

EX

EX

EX

EX

EX

EX

002.1.01

002.1.02

002.1.03

002.1.05

EX

TELECOM

ROOM

N108A

1 (TYP)

RISK: MEDIUM

INFECTION CONTROL PRECAUTION: CLASS IV

RISK: MEDIUM

INFECTION CONTROL PRECAUTION: CLASS IV

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Fi le

P at h

U.S. Department of Veterans Affairs

B

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

STAMPCONSULTANT

321 4 5 6 7 8 9 10

Project Director

Revisions: Date:

Key Plan

Electronic Health Records Modernization (EHRM) Infrastructure Upgrades - Long Beach

5901 E. SEVENTH STREET, LONG BEACH, CA 90822

600-20-120

CONTRACT DOCUMENTS

December 16, 2020 JC GB

FULLY SPRINKLERED

NORTH

A

GENERAL NOTES

KEY NOTES

17075 Via Del Campo, San Diego, CA 92127 Phone: 858.946.0333

ARCHITECT/ENGINEER OF RECORD

0' 4' 16' 24'2' 8'SCALE: 3/32" = 1'-0"

C

D

20801.10

ARCHITECTURAL FIRST FLOOR

PLAN

ARCHITECTURAL FIRST FLOOR PLAN

2.A-111

NORTH

1. REMOVE AND REINSTALL CEILING AS REQUIRED FOR

RUNNING CABLING.

BUILDING 2

F1

E4 A-402

B4 A-402

DOOR RATING LEGEND

NON-RATED SMOKE- RESISTANT

FIRE DOOR

20-MINUTE RATED FIRE DOOR

45-MINUTE RATED FIRE DOOR

60-MINUTE RATED FIRE DOOR

90-MINUTE RATED FIRE DOOR

90-MINUTE SMOKE- RESISTANT

FIRE DOOR

180-MINUTE RATED FIRE DOOR

RATED DOOR TAG

(XX:BLDG; YY: LEVEL; Z:ID; W:MINUTES)

EX

EXIT STAIR

HAZARDOUS ROOM (NFPA 101 §8.7)

INTERIOR EXIT LOCATION

EXTERIOR EXIT DISCHARGE

WALL TYPE LEGEND

HZ

3-HR. FIRE BARRIER

2-HR. FIRE/SMOKE BARRIER

1-HR. FIRE/SMOKE BARRIER

SMOKE BARRIER

SMOKE PARTITION

INTERIOR EXIT PASSAGEWAY

LIFE SAFETY LEGEND

1. PROVIDE UL LISTED FIRESTOPPING AT ALL

PENETRATIONS OF FIRE RATED WALLS.

2. USE EZ PATH OR SIMILAR TO ALLOW CABLES TO

PENETRATE WALLS, W/O LIMITING ABILITY TO

ADD/REMOVE CABLES AT A LATER TIME W/O RESEALING.

3. COORDINATE RELOCATION OF EXISTING EQUIPMENT

AND FURNITURE WITH THE VA AS INDICATED ON

PROJECT NOTE 5 ON GI001.

4. BUILDING 2 CONTAINS HAZARDOUS MATERIALS, REFER

TO GI003.

INFECTION CONTROL

NOTES

1. ALL AREAS ON THIS PLAN SHALL BE CONSIDERED

CONSTRUCTION TYPE D, LOW RISK GROUP AND

INFECTION CONTROL PRECAUTION CLASS IV UNLESS

OTHERWISE NOTED.

FEMALE

TOILET

TOILET

CO

RR

ID

OR

CC

2-

2-

CHAPLAIN SERVICE

ALTAR

247A

CHAPEL AREA

CO

RR

ID

OR

CC

2-

2-

CORRIDOR

CC2-2-4

PHARMACY

SUPPLIES

214-P

ALCOHOL

RM

211-P

VAULT

212-P

RESEARCH

PHARMACY

213-P

OFFICE

204-P

PRAYER

RM

LOUNGE

OFFICE

SECRETARY

CHAPLAIN

SERVICE

CHAPLAIN

OFFICE

CHAPLAIN

OFFICE

243STORAGE

CHAPLAIN

OFFICE

CHIEF

CHAPLAIN

SVC OFFICE

STORAGE

247C

STORAGE

247B

MALE

KITCHEN

GENERAL

STORAGE

EQUIPMENT

STORAGE

PANTAGES THEATER

STAIR

CO

RR

ID

OR

CC

2-

2-

5STAGE

DR

ES

SI

NG

RM 26

ST

AI

R

STAIR

GENERAL

STORAGE

HR

FILES

HAC

205-P

215-P

206-P

OFFICE

210-P

SHAFT

SHAFT

SHAFT

PHARMACY

PHARMACY

PHARMACY

HZ

HZ

HZ

HZ

HZHZ

HZ

HZ

HZ

HZ

HZ

HZ

EX

EX

EX EX EX

EX

EX

EX

HZEX

HZ

HZ

1 (TYP)

RISK: HIGH

INFECTION CONTROL PRECAUTION: CLASS IV

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Fi le

P at h

U.S. Department of Veterans Affairs

B

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

STAMPCONSULTANT

321 4 5 6 7 8 9 10

Project Director

Revisions: Date:

Key Plan

Electronic Health Records Modernization (EHRM) Infrastructure Upgrades - Long Beach

5901 E. SEVENTH STREET, LONG BEACH, CA 90822

600-20-120

CONTRACT DOCUMENTS

December 16, 2020 JC GB

FULLY SPRINKLERED

NORTH

A

GENERAL NOTES

KEY NOTES

17075 Via Del Campo, San Diego, CA 92127 Phone: 858.946.0333

ARCHITECT/ENGINEER OF RECORD

0' 4' 16' 24'2' 8'SCALE: 3/32" = 1'-0"

C

D

20801.10

ARCHITECTURAL SECOND FLOOR

PLAN

ARCHITECTURAL SECOND FLOOR PLAN

2.A-121

NORTH

1. REMOVE AND REINSTALL CEILING AS REQUIRED FOR

RUNNING CABLING.

BUILDING 2

F1

DOOR RATING LEGEND

NON-RATED SMOKE- RESISTANT

FIRE DOOR

20-MINUTE RATED FIRE DOOR

45-MINUTE RATED FIRE DOOR

60-MINUTE RATED FIRE DOOR

90-MINUTE RATED FIRE DOOR

90-MINUTE SMOKE- RESISTANT

FIRE DOOR

180-MINUTE RATED FIRE DOOR

RATED DOOR TAG

(XX:BLDG; YY: LEVEL; Z:ID; W:MINUTES)

EX

EXIT STAIR

HAZARDOUS ROOM (NFPA 101 §8.7)

INTERIOR EXIT LOCATION

EXTERIOR EXIT DISCHARGE

WALL TYPE LEGEND

HZ

3-HR. FIRE BARRIER

2-HR. FIRE/SMOKE BARRIER

1-HR. FIRE/SMOKE BARRIER

SMOKE BARRIER

SMOKE PARTITION

INTERIOR EXIT PASSAGEWAY

LIFE SAFETY LEGEND

1. PROVIDE UL LISTED FIRESTOPPING AT ALL

PENETRATIONS OF FIRE RATED WALLS.

2. USE EZ PATH OR SIMILAR TO ALLOW CABLES TO

PENETRATE WALLS, W/O LIMITING ABILITY TO

ADD/REMOVE CABLES AT A LATER TIME W/O RESEALING.

3. COORDINATE RELOCATION OF EXISTING EQUIPMENT

AND FURNITURE WITH THE VA AS INDICATED ON

PROJECT NOTE 5 ON GI001.

4. BUILDING 2 CONTAINS HAZARDOUS MATERIALS, REFER

TO GI003.

INFECTION CONTROL

NOTES

1. ALL AREAS ON THIS PLAN SHALL BE CONSIDERED

CONSTRUCTION TYPE D, LOW RISK GROUP AND

INFECTION CONTROL PRECAUTION CLASS IV UNLESS

OTHERWISE NOTED.

ST

OR

AG

E

RESTROOM

MENS RESTROOM

STAIR

ST

AI

R

9STORAGE

STAIR

LIBRARY

305A

LIBRARIAN

OFFICE

345D

HVAC FAN RM

ADMIN

COMPUTER RM

346B

CONFERENCE

RM

346A

304K

OFFICE

OFFICE

304C

SYSTEMS

REDESIGN

304B

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

304F

304E

304D

OFFICE

304A

304JCO

RR

ID

OR

304G

304H

RADIO RM

STORAGE

STORAGE

STORAGE

PROJECTOR

RM

CO

RR

ID

OR

FIRE APPARATUS

351A

352A

CHECKOUT

345A

HZ

EX

EX

002.3.01

HZ HZ

HZ

HZ

002.3.02 45 002.3.03

1 (TYP)

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Fi le

P at h

U.S. Department of Veterans Affairs

B

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

STAMPCONSULTANT

321 4 5 6 7 8 9 10

Project Director

Revisions: Date:

Key Plan

Electronic Health Records Modernization (EHRM) Infrastructure Upgrades - Long Beach

5901 E. SEVENTH STREET, LONG BEACH, CA 90822

600-20-120

CONTRACT DOCUMENTS

December 16, 2020 JC GB

FULLY SPRINKLERED

NORTH

A

GENERAL NOTES

KEY NOTES

17075 Via Del Campo, San Diego, CA 92127 Phone: 858.946.0333

ARCHITECT/ENGINEER OF RECORD

0' 4' 16' 24'2' 8'SCALE: 3/32" = 1'-0"

C

D

20801.10

ARCHITECTURAL THIRD FLOOR

PLAN

ARCHITECTURAL THIRD FLOOR PLAN

2.A-131

NORTH

1. REMOVE AND REINSTALL CEILING AS REQUIRED FOR

RUNNING CABLING.

BUILDING 2

F1

DOOR RATING LEGEND

NON-RATED SMOKE- RESISTANT

FIRE DOOR

20-MINUTE RATED FIRE DOOR

45-MINUTE RATED FIRE DOOR

60-MINUTE RATED FIRE DOOR

90-MINUTE RATED FIRE DOOR

90-MINUTE SMOKE- RESISTANT

FIRE DOOR

180-MINUTE RATED FIRE DOOR

RATED DOOR TAG

(XX:BLDG; YY: LEVEL; Z:ID; W:MINUTES)

EX

EXIT STAIR

HAZARDOUS ROOM (NFPA 101 §8.7)

INTERIOR EXIT LOCATION

EXTERIOR EXIT DISCHARGE

WALL TYPE LEGEND

HZ

3-HR. FIRE BARRIER

2-HR. FIRE/SMOKE BARRIER

1-HR. FIRE/SMOKE BARRIER

SMOKE BARRIER

SMOKE PARTITION

INTERIOR EXIT PASSAGEWAY

LIFE SAFETY LEGEND

1. PROVIDE UL LISTED FIRESTOPPING AT ALL

PENETRATIONS OF FIRE RATED WALLS.

2. USE EZ PATH OR SIMILAR TO ALLOW CABLES TO

PENETRATE WALLS, W/O LIMITING ABILITY TO

ADD/REMOVE CABLES AT A LATER TIME W/O RESEALING.

3. COORDINATE RELOCATION OF EXISTING EQUIPMENT

AND FURNITURE WITH THE VA AS INDICATED ON

PROJECT NOTE 5 ON GI001.

4. BUILDING 2 CONTAINS HAZARDOUS MATERIALS, REFER

TO GI003.

INFECTION CONTROL

NOTES

1. ALL AREAS ON THIS PLAN SHALL BE CONSIDERED

CONSTRUCTION TYPE D, LOW RISK GROUP AND

INFECTION CONTROL PRECAUTION CLASS IV UNLESS

OTHERWISE NOTED.

BREAK

E-125

SAMPLES

E-105

FILES

STORAGE

HA

LL

W

AY

E-

HALLWAY

P-101

HA

LL

W

AY

P-

BREAK

P-120

LOBBY

P-100

COUNTER

P-102

PRINT/FAX

P-110

HALLWAY

E-100

HA

LL

W

AY

E-

HALLWAY

E-124

BREAK

E-128

CORRIDOR

E-102

REPORT

P-109

SGT

P-108

CAPT

P-107

CAPT

P-106

CHIEF

P-105ADMIN

P-103

TRAINING/

ARMORY

P-122

COMM

P-124

DISPATCHER

P-123

CLASSROOM/

COMMAND

CENTER

P-125

MENS LOCKER

P-117

WOMENS TOILET

P-116

WOMENS

LOCKER

P-115

JAN

P-114

IT RM

E-107

CONFERENCE RM

E-106

MENS TOILET

P-118

MENS TOILET

E-126

DRAWING STORAGE

E-123

WOMENS TOILET

E-127

ELECTRICAL

CLOSET

E-131

COPY/FAX

E-130

HAC

E-129

HOLD

P-113

STORAGE

P-112 INVEST

P-111

MECH

E-132

IT/DATA

E-108

ENG

E-109

ENG

E-110

ENG

E-111

ENG

E-112

CLERK

E-113

SR RES

E-114RES ENG

E-115

RES ENG

E-116

RES ENG

E-117

ID CHIEF

E-104

CONFERENCE

RM

E-118

CAD ENG

E-122

ENG

E-121

LIBRARY

E-120

COPY/ FAX

E-119

TELECOM ROOM

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Fi le

P at h

U.S. Department of Veterans Affairs

B

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

STAMPCONSULTANT

321 4 5 6 7 8 9 10

Project Director

Revisions: Date:

Key Plan

Electronic Health Records Modernization (EHRM) Infrastructure Upgrades - Long Beach

5901 E. SEVENTH STREET, LONG BEACH, CA 90822

600-20-120

CONTRACT DOCUMENTS

December 16, 2020 JC GB

FULLY SPRINKLERED

NORTH

A

GENERAL NOTES

KEY NOTES

17075 Via Del Campo, San Diego, CA 92127 Phone: 858.946.0333

ARCHITECT/ENGINEER OF RECORD

SCALE: 1/8" = 1'-0" 0' 4' 8' 16'

C

D

20801.10

ARCHITECTURAL FIRST FLOOR

PLAN

ARCHITECTURAL FIRST FLOOR PLAN

5C.A-111

NORTH

5C

BUILDING 5C

F1

E7 A-402

B7 A-402

DOOR RATING LEGEND

NON-RATED SMOKE- RESISTANT

FIRE DOOR

20-MINUTE RATED FIRE DOOR

45-MINUTE RATED FIRE DOOR

60-MINUTE RATED FIRE DOOR

90-MINUTE RATED FIRE DOOR

90-MINUTE SMOKE- RESISTANT

FIRE DOOR

180-MINUTE RATED FIRE DOOR

RATED DOOR TAG

(XX:BLDG; YY: LEVEL; Z:ID; W:MINUTES)

EX

EXIT STAIR

HAZARDOUS ROOM (NFPA 101 §8.7)

INTERIOR EXIT LOCATION

EXTERIOR EXIT DISCHARGE

WALL TYPE LEGEND

HZ

3-HR. FIRE BARRIER

2-HR. FIRE/SMOKE BARRIER

1-HR. FIRE/SMOKE BARRIER

SMOKE BARRIER

SMOKE PARTITION

INTERIOR EXIT PASSAGEWAY

LIFE SAFETY LEGEND

INFECTION CONTROL

NOTES

1. ALL AREAS ON THIS PLAN SHALL BE CONSIDERED

CONSTRUCTION TYPE C, LOW RISK GROUP AND

INFECTION CONTROL PRECAUTION CLASS II UNLESS

OTHERWISE NOTED.

TELEPHONE

GENERAL

MECHANIC

SHOP

ENGINEERING SHOPS

STORAGE

TOILET

WELDING SHOP

GENERAL MECHANIC SHOP

BREAK RM

STORAGE

PIPE SHOP

SUPERVISOR

MOTOR POOL

OFFICE

OFFICE

OFFICE

VAULT

BREAK RM

GENERAL

STORAGE

TOILET

TOILET

HVAC SHOP

STORAGE

ELECTRICAL RM

38A

TELECOM ROOM

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Fi le

P at h

U.S. Department of Veterans Affairs

B

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

STAMPCONSULTANT

321 4 5 6 7 8 9 10

Project Director

Revisions: Date:

Key Plan

Electronic Health Records Modernization (EHRM) Infrastructure Upgrades - Long Beach

5901 E. SEVENTH STREET, LONG BEACH, CA 90822

600-20-120

CONTRACT DOCUMENTS

December 16, 2020 JC GB

FULLY SPRINKLERED

NORTH

A

GENERAL NOTES

KEY NOTES

17075 Via Del Campo, San Diego, CA 92127 Phone: 858.946.0333

ARCHITECT/ENGINEER OF RECORD

0' 4' 16' 24'2' 8'SCALE: 3/32" = 1'-0"

C

D

20801.10

ARCHITECTURAL FIRST FLOOR

PLAN

ARCHITECTURAL FIRST FLOOR PLAN

6.A-111

NORTH

BUILDING 6

F1

E1 A-403

B1 A-403

DOOR RATING LEGEND

NON-RATED SMOKE- RESISTANT

FIRE DOOR

20-MINUTE RATED FIRE DOOR

45-MINUTE RATED FIRE DOOR

60-MINUTE RATED FIRE DOOR

90-MINUTE RATED FIRE DOOR

90-MINUTE SMOKE- RESISTANT

FIRE DOOR

180-MINUTE RATED FIRE DOOR

RATED DOOR TAG

(XX:BLDG; YY: LEVEL; Z:ID; W:MINUTES)

EX

EXIT STAIR

HAZARDOUS ROOM (NFPA 101 §8.7)

INTERIOR EXIT LOCATION

EXTERIOR EXIT DISCHARGE

WALL TYPE LEGEND

HZ

3-HR. FIRE BARRIER

2-HR. FIRE/SMOKE BARRIER

1-HR. FIRE/SMOKE BARRIER

SMOKE BARRIER

SMOKE PARTITION

INTERIOR EXIT PASSAGEWAY

LIFE SAFETY LEGEND

1. BUILDING 6 CONTAINS HAZARDOUS MATERIALS, REFER

TO GI003.

INFECTION CONTROL

NOTES

1. ALL AREAS ON THIS PLAN SHALL BE CONSIDERED

CONSTRUCTION TYPE C, LOW RISK GROUP AND

INFECTION CONTROL PRECAUTION CLASS II UNLESS

OTHERWISE NOTED.

CO

NN

EC

TI

NG

CO

RR

ID

OR

CC

7- B-

FAN RM

HAC

11GENERAL

STORAGE

HAC

STORAGE

11-A

STORAGE RM

11-B

EQUIP

RM

12-A

ELECTRICAL

TRANSFORMER RM

13-A

SUBSTATION(POWER) 12KV

EDISON RM

HAC STORAGE

GENERAL

STORAGE

17A

GENERAL

STORAGE

17B

CONNECTING

CORRIDOR

CC7-B-2

GENERAL

STORAGE

FEC

STAIR

TELECOM

CLOSET

GENERAL

STORAGE

20A

STORAGE

12B

EX

1 (TYP)

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Fi le

P at h

U.S. Department of Veterans Affairs

B

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

STAMPCONSULTANT

321 4 5 6 7 8 9 10

Project Director

Revisions: Date:

Key Plan

Electronic Health Records Modernization (EHRM) Infrastructure Upgrades - Long Beach

5901 E. SEVENTH STREET, LONG BEACH, CA 90822

600-20-120

CONTRACT DOCUMENTS

December 16, 2020 JC GB

FULLY SPRINKLERED

NORTH

A

GENERAL NOTES

KEY NOTES

17075 Via Del Campo, San Diego, CA 92127 Phone: 858.946.0333

ARCHITECT/ENGINEER OF RECORD

0' 4' 16' 24'2' 8'SCALE: 3/32" = 1'-0"

C

D

20801.10

ARCHITECTURAL BASEMENT

FLOOR PLAN

ARCHITECTURAL BASEMENT FLOOR PLAN

7.A-101

NORTH

1. REMOVE AND REINSTALL CEILING AS REQUIRED FOR

RUNNING CABLING.

BUILDING 7

F1

DOOR RATING LEGEND

NON-RATED SMOKE- RESISTANT

FIRE DOOR

20-MINUTE RATED FIRE DOOR

45-MINUTE RATED FIRE DOOR

60-MINUTE RATED FIRE DOOR

90-MINUTE RATED FIRE DOOR

90-MINUTE SMOKE- RESISTANT

FIRE DOOR

180-MINUTE RATED FIRE DOOR

RATED DOOR TAG

(XX:BLDG; YY: LEVEL; Z:ID; W:MINUTES)

EX

EXIT STAIR

HAZARDOUS ROOM (NFPA 101 §8.7)

INTERIOR EXIT LOCATION

EXTERIOR EXIT DISCHARGE

WALL TYPE LEGEND

HZ

3-HR. FIRE BARRIER

2-HR. FIRE/SMOKE BARRIER

1-HR. FIRE/SMOKE BARRIER

SMOKE BARRIER

SMOKE PARTITION

INTERIOR EXIT PASSAGEWAY

LIFE SAFETY LEGEND

1. PROVIDE UL LISTED FIRESTOPPING AT ALL

PENETRATIONS OF FIRE RATED WALLS.

2. USE EZ PATH OR SIMILAR TO ALLOW CABLES TO

PENETRATE WALLS, W/O LIMITING ABILITY TO

ADD/REMOVE CABLES AT A LATER TIME W/O RESEALING.

3. COORDINATE RELOCATION OF EXISTING EQUIPMENT

AND FURNITURE WITH THE VA AS INDICATED ON

PROJECT NOTE 5 ON GI001.

INFECTION CONTROL

NOTES

1. ALL AREAS ON THIS PLAN SHALL BE CONSIDERED

CONSTRUCTION TYPE D, LOW RISK GROUP AND

INFECTION CONTROL PRECAUTION CLASS IV UNLESS

OTHERWISE NOTED.

EX

EXEX

EX

EX

EX

HZ

HZ

HZ

MICROBIOLOGY

103B

OFFICE

103A

STORAGE

IMMUNO-HISTOLOGY

CHEMISTRY

GROSSING

WOMENS

TOILET

MENS

TOILET

CASHIER

OFFICE

CORRIDOR

SWING

100B

HOUSE

KEEPING

101 OUT PATIENT

PHARMACY

WAITING AREA

WAITING AREA

ETHICS OFFICE

OF THE DIRECTOR

100A

HAC STORAGE

TRAVEL

OFFICE

STAIR

STAIR

NO 2

101A

105A

C7-1-1

103C

103M

RECVG

103D 103E

103K

BREAK

RM OFFICE

103H 103F 103G

HALL WAY

EMP AREA

HISTOLOGY

1 (TYP)

RISK: HIGH

INFECTION CONTROL PRECAUTION: CLASS IV

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Fi le

P at h

U.S. Department of Veterans Affairs

B

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

STAMPCONSULTANT

321 4 5 6 7 8 9 10

Project Director

Revisions: Date:

Key Plan

Electronic Health Records Modernization (EHRM) Infrastructure Upgrades - Long Beach

5901 E. SEVENTH STREET, LONG BEACH, CA 90822

600-20-120

CONTRACT DOCUMENTS

December 16, 2020 JC GB

FULLY SPRINKLERED

NORTH

A

GENERAL NOTES

KEY NOTES

17075 Via Del Campo, San Diego, CA 92127 Phone: 858.946.0333

ARCHITECT/ENGINEER OF RECORD

0' 4' 16' 24'2' 8'SCALE: 3/32" = 1'-0"

C

D

20801.10

ARCHITECTURAL FIRST FLOOR

PLAN

ARCHITECTURAL FIRST FLOOR PLAN

7.A-111

NORTH

1. REMOVE AND REINSTALL CEILING AS REQUIRED FOR

RUNNING CABLING.

2. SEE TELECOMMUNICATIONS SHEET 7.T-111 FOR FIBER

ROUTING WITHIN WALL. REPAIR EXISTING WALL SURFACE

AND FINISH TO MATCH EXISTING.

BUILDING 7

F1

DOOR RATING LEGEND

NON-RATED SMOKE- RESISTANT

FIRE DOOR

20-MINUTE RATED FIRE DOOR

45-MINUTE RATED FIRE DOOR

60-MINUTE RATED FIRE DOOR

90-MINUTE RATED FIRE DOOR

90-MINUTE SMOKE- RESISTANT

FIRE DOOR

180-MINUTE RATED FIRE DOOR

RATED DOOR TAG

(XX:BLDG; YY: LEVEL; Z:ID; W:MINUTES)

EX

EXIT STAIR

HAZARDOUS ROOM (NFPA 101 §8.7)

INTERIOR EXIT LOCATION

EXTERIOR EXIT DISCHARGE

WALL TYPE LEGEND

HZ

3-HR. FIRE BARRIER

2-HR. FIRE/SMOKE BARRIER

1-HR. FIRE/SMOKE BARRIER

SMOKE BARRIER

SMOKE PARTITION

INTERIOR EXIT PASSAGEWAY

LIFE SAFETY LEGEND

1. PROVIDE UL LISTED FIRESTOPPING AT ALL

PENETRATIONS OF FIRE RATED WALLS.

2. USE EZ PATH OR SIMILAR TO ALLOW CABLES TO

PENETRATE WALLS, W/O LIMITING ABILITY TO

ADD/REMOVE CABLES AT A LATER TIME W/O RESEALING.

3. COORDINATE RELOCATION OF EXISTING EQUIPMENT

AND FURNITURE WITH THE VA AS INDICATED ON

PROJECT NOTE 5 ON GI001.

INFECTION CONTROL

NOTES

1. ALL AREAS ON THIS PLAN SHALL BE CONSIDERED

CONSTRUCTION TYPE D, LOW RISK GROUP AND

INFECTION CONTROL PRECAUTION CLASS IV UNLESS

OTHERWISE NOTED.

CLOSET

ELECTRICAL

ELECTRICAL

SOILED

UTILITIES

FEC

MINOR SURGY

LASER RM

EXAM

RM

223A

CONNECTING

CORRIDOR

CO

NN

EC

TI

NG

CO

RR

ID

OR

HAC

STORAGE

CONFERENCE

RM

TECHS SUPV

OFFICE

200E

BREAK RM

200D

CASE MGR

OFFICE

200C

STORAGE

200B-A

ULTRA

SOUND RM

GENERAL

STORAGE

EX

AM

R M

OFFICE

RECEPTION

WAITING

AREA

EX

AM

R M

4C

EX

AM

R M

4B

V I S T

CO-ORDINATIOR

OFFICE

213A

CLEAN

UTILITIES

OPHTHALMOLOGY

OFFICE

EXAM RM

TELTOILET

209B

CHIEF OFFICE

SECY

214N

EXAM RM

214M

EX

AM

R M

4L

CLINIC

NURSE

214K

EX

AM

R M

4H

EX

AM

R M

4G

EX

AM

R M

4F

EX

AM

R M

4E

FITTING

RM

223C

STAIR

EY

E

E

XA

M

RM

4D

EYE

EXAM

RM

STAIR

NO 2209A

200A

222A

222B

221A

HAC 200BHZ

HZ

HZ HZ HZ EX

EX

007.2.01

007.2.02

007.2.03

1 (TYP)

RISK: MEDIUM

INFECTION CONTROL PRECAUTION: CLASS IV

RISK: MEDIUM

INFECTION CONTROL PRECAUTION: CLASS IV

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Fi le

P at h

U.S. Department of Veterans Affairs

B

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

STAMPCONSULTANT

321 4 5 6 7 8 9 10

Project Director

Revisions: Date:

Key Plan

Electronic Health Records Modernization (EHRM) Infrastructure Upgrades - Long Beach

5901 E. SEVENTH STREET, LONG BEACH, CA 90822

600-20-120

CONTRACT DOCUMENTS

December 16, 2020 JC GB

FULLY SPRINKLERED

NORTH

A

GENERAL NOTES

KEY NOTES

17075 Via Del Campo, San Diego, CA 92127 Phone: 858.946.0333

ARCHITECT/ENGINEER OF RECORD

0' 4' 16' 24'2' 8'SCALE: 3/32" = 1'-0"

C

D

20801.10

ARCHITECTURAL SECOND FLOOR

PLAN

ARCHITECTURAL SECOND FLOOR PLAN

7.A-121

NORTH

1. REMOVE AND REINSTALL CEILING AS REQUIRED FOR

RUNNING CABLING.

BUILDING 7

F1

DOOR RATING LEGEND

NON-RATED SMOKE- RESISTANT

FIRE DOOR

20-MINUTE RATED FIRE DOOR

45-MINUTE RATED FIRE DOOR

60-MINUTE RATED FIRE DOOR

90-MINUTE RATED FIRE DOOR

90-MINUTE SMOKE- RESISTANT

FIRE DOOR

180-MINUTE RATED FIRE DOOR

RATED DOOR TAG

(XX:BLDG; YY: LEVEL; Z:ID; W:MINUTES)

EX

EXIT STAIR

HAZARDOUS ROOM (NFPA 101 §8.7)

INTERIOR EXIT LOCATION

EXTERIOR EXIT DISCHARGE

WALL TYPE LEGEND

HZ

3-HR. FIRE BARRIER

2-HR. FIRE/SMOKE BARRIER

1-HR. FIRE/SMOKE BARRIER

SMOKE BARRIER

SMOKE PARTITION

INTERIOR EXIT PASSAGEWAY

LIFE SAFETY LEGEND

1. PROVIDE UL LISTED FIRESTOPPING AT ALL

PENETRATIONS OF FIRE RATED WALLS.

2. USE EZ PATH OR SIMILAR TO ALLOW CABLES TO

PENETRATE WALLS, W/O LIMITING ABILITY TO

ADD/REMOVE CABLES AT A LATER TIME W/O RESEALING.

3. COORDINATE RELOCATION OF EXISTING EQUIPMENT

AND FURNITURE WITH THE VA AS INDICATED ON

PROJECT NOTE 5 ON GI001.

INFECTION CONTROL

NOTES

1. ALL AREAS ON THIS PLAN SHALL BE CONSIDERED

CONSTRUCTION TYPE D, LOW RISK GROUP AND

INFECTION CONTROL PRECAUTION CLASS IV UNLESS

OTHERWISE NOTED.

WAITING

AREA

EXAM RM

303A

VASCULAR

RESEARCH

303B

EXAM RM

300F

RESEARCH

CO-ORDR

RESEARCH

RM

EXAM RM

ALLERGY/

IMMUNOLOGY CLINIC

EXAM RM

328A

WAITING

AREA

ALLERGY

CLINIC

300A

ALLERGY

CLINIC

300B

ALLERGY

CLINIC

300C

ALLERGY

CLINIC

300D

ALLERGY

LAB

300E

CO

RR

ID

OR

EXAM RM

303C

EXAM RM

ALCOVE

TEL

309OFFICE

310B

OFFICE

310A

HAC RM

OXYGEN

STORAGE

EXAM RM

EXAM RM

ST

OR

AG

E

7A

EXAM RM

RESEARCH

RM

VASCULAR

SURGY

RESEARCH

OFFICE

EXAM RM

ELECTRICAL

MEDICATION

RM

OFFICE

EXAM RM

MENS RM

WOMENS RM

EXAM RM

EXAM RM

EXAM RM

EXAM RM

EXAM RM

EXAM RM

328B

EXAM RM

328D

EXAM

RM

328C

STAIR

STAIR

NO 2

ELECTRICAL PANEL

C7 -3

-1

300C-1

EX

EX

007.3.02

007.3.01

HZ

HZ

HZ

007.3.03

1 (TYP)

RISK: MEDIUM

INFECTION CONTROL PRECAUTION: CLASS IV

RISK: MEDIUM

INFECTION CONTROL PRECAUTION: CLASS IV

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Fi le

P at h

U.S. Department of Veterans Affairs

B

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

STAMPCONSULTANT

321 4 5 6 7 8 9 10

Project Director

Revisions: Date:

Key Plan

Electronic Health Records Modernization (EHRM) Infrastructure Upgrades - Long Beach

5901 E. SEVENTH STREET, LONG BEACH, CA 90822

600-20-120

CONTRACT DOCUMENTS

December 16, 2020 JC GB

FULLY SPRINKLERED

NORTH

A

GENERAL NOTES

KEY NOTES

17075 Via Del Campo, San Diego, CA 92127 Phone: 858.946.0333

ARCHITECT/ENGINEER OF RECORD

0' 4' 16' 24'2' 8'SCALE: 3/32" = 1'-0"

C

D

20801.10

ARCHITECTURAL THIRD FLOOR

PLAN

ARCHITECTURAL THIRD FLOOR PLAN

7.A-131

NORTH

1. REMOVE AND REINSTALL CEILING AS REQUIRED FOR

RUNNING CABLING.

BUILDING 7

F1

DOOR RATING LEGEND

NON-RATED SMOKE- RESISTANT

FIRE DOOR

20-MINUTE RATED FIRE DOOR

45-MINUTE RATED FIRE DOOR

60-MINUTE RATED FIRE DOOR

90-MINUTE RATED FIRE DOOR

90-MINUTE SMOKE- RESISTANT

FIRE DOOR

180-MINUTE RATED FIRE DOOR

RATED DOOR TAG

(XX:BLDG; YY: LEVEL; Z:ID; W:MINUTES)

EX

EXIT STAIR

HAZARDOUS ROOM (NFPA 101 §8.7)

INTERIOR EXIT LOCATION

EXTERIOR EXIT DISCHARGE

WALL TYPE LEGEND

HZ

3-HR. FIRE BARRIER

2-HR. FIRE/SMOKE BARRIER

1-HR. FIRE/SMOKE BARRIER

SMOKE BARRIER

SMOKE PARTITION

INTERIOR EXIT PASSAGEWAY

LIFE SAFETY LEGEND

1. PROVIDE UL LISTED FIRESTOPPING AT ALL

PENETRATIONS OF FIRE RATED WALLS.

2. USE EZ PATH OR SIMILAR TO ALLOW CABLES TO

PENETRATE WALLS, W/O LIMITING ABILITY TO

ADD/REMOVE CABLES AT A LATER TIME W/O

RESEALING.

3. COORDINATE RELOCATION OF EXISTING EQUIPMENT

AND FURNITURE WITH THE VA AS INDICATED ON

PROJECT NOTE 5 ON GI001.

INFECTION CONTROL

NOTES

1. ALL AREAS ON THIS PLAN SHALL BE CONSIDERED

CONSTRUCTION TYPE D, LOW RISK GROUP AND

INFECTION CONTROL PRECAUTION CLASS IV UNLESS

OTHERWISE NOTED.

CO

RR

ID

OR

CC

-B

8-

EQUIP

STORAGE

CORRIDOR

CC-B8-5

CARDIOLOGY

STORAGE

19B

CO

RR

ID

OR

CC

-B

8-

STORAGE

18-004

STAIR

FILTER RM

CO

RR

ID

OR

CC

-B

8-

BOILER

17A

ELECTRICAL VAULT

ELECTRICAL CLOSET

COMPRESSOR

15A

HALLWAY

CC-B8-1

BOILER RM

ENGG

STORAGE

GENERAL

STORAGE

HAC

BUILDING MGMT STORAGE

BUILDING MGMT STORAGE

MED MEDIA STORAGE RM

HALLWAY

MECH RM

EX EX

EX

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Fi le

P at h

U.S. Department of Veterans Affairs

B

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

STAMPCONSULTANT

321 4 5 6 7 8 9 10

Project Director

Revisions: Date:

Key Plan

Electronic Health Records Modernization (EHRM) Infrastructure Upgrades - Long Beach

5901 E. SEVENTH STREET, LONG BEACH, CA 90822

600-20-120

CONTRACT DOCUMENTS

December 16, 2020 JC GB

FULLY SPRINKLERED

NORTH

A

GENERAL NOTES

KEY NOTES

17075 Via Del Campo, San Diego, CA 92127 Phone: 858.946.0333

ARCHITECT/ENGINEER OF RECORD

0' 4' 16' 24'2' 8'SCALE: 3/32" = 1'-0"

C

D

20801.10

ARCHITECTURAL BASEMENT

FLOOR PLAN (FOR REFERENCE

ONLY)

ARCHITECTURAL BASEMENT FLOOR PLAN (FOR REFERENCE ONLY)

8.A-101

NORTH

BUILDING 8

F1

DOOR RATING LEGEND

NON-RATED SMOKE- RESISTANT

FIRE DOOR

20-MINUTE RATED FIRE DOOR

45-MINUTE RATED FIRE DOOR

60-MINUTE RATED FIRE DOOR

90-MINUTE RATED FIRE DOOR

90-MINUTE SMOKE- RESISTANT

FIRE DOOR

180-MINUTE RATED FIRE DOOR

RATED DOOR TAG

(XX:BLDG; YY: LEVEL; Z:ID; W:MINUTES)

EX

EXIT STAIR

HAZARDOUS ROOM (NFPA 101 §8.7)

INTERIOR EXIT LOCATION

EXTERIOR EXIT DISCHARGE

WALL TYPE LEGEND

HZ

3-HR. FIRE BARRIER

2-HR. FIRE/SMOKE BARRIER

1-HR. FIRE/SMOKE BARRIER

SMOKE BARRIER

SMOKE PARTITION

INTERIOR EXIT PASSAGEWAY

LIFE SAFETY LEGEND

ELEC

FEC

117A1

CORRIDOR

CC-8-1

CO

RR

ID

OR

CC

-8

-3

CO

RR

ID

OR

CC

-8 -2

CORRIDOR

CC-8-5

CORRIDOR

CC-8-4

STAIR

NO-2

FILE RM

119A

OCCUPATION HEALTH

NURSE

TRIAGE

EXAM

NU

RS

E

TR

IA

GE

EXAM

TEL

CO

ELEC

CO

AG

EN

T

OF

FI

CE

4MENS

TOILET

WOMENS

TOILET

TEL RM

TEAMLET RM

EXAM

VET SVC

OFFICE

DAV OFFICE

AM VETS

OFFICE

VVA OFFICE

VSO WAITING RM

VSO OFFICE

VSO OFFICE

TRASH AND

LINEN

103HAC

OFFICE

VOLUNTEERS

OFFICE

STAIR

NO 3

100AEX

EX

EX

HZ

HZ

EX

HZ

TELECOM ROOM

RISK: MEDIUM

INFECTION CONTROL PRECAUTION: CLASS IV

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Fi le

P at h

U.S. Department of Veterans Affairs

B

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

STAMPCONSULTANT

321 4 5 6 7 8 9 10

Project Director

Revisions: Date:

Key Plan

Electronic Health Records Modernization (EHRM) Infrastructure Upgrades - Long Beach

5901 E. SEVENTH STREET, LONG BEACH, CA 90822

600-20-120

CONTRACT DOCUMENTS

December 16, 2020 JC GB

FULLY SPRINKLERED

NORTH

A

GENERAL NOTES

KEY NOTES

17075 Via Del Campo, San Diego, CA 92127 Phone: 858.946.0333

ARCHITECT/ENGINEER OF RECORD

0' 4' 16' 24'2' 8'SCALE: 3/32" = 1'-0"

C

D

20801.10

ARCHITECTURAL FIRST FLOOR

PLAN

ARCHITECTURAL FIRST FLOOR PLAN

8.A-111

NORTH

BUILDING 8

F1

E4 A-403

B4 A-403

DOOR RATING LEGEND

NON-RATED SMOKE- RESISTANT

FIRE DOOR

20-MINUTE RATED FIRE DOOR

45-MINUTE RATED FIRE DOOR

60-MINUTE RATED FIRE DOOR

90-MINUTE RATED FIRE DOOR

90-MINUTE SMOKE- RESISTANT

FIRE DOOR

180-MINUTE RATED FIRE DOOR

RATED DOOR TAG

(XX:BLDG; YY: LEVEL; Z:ID; W:MINUTES)

EX

EXIT STAIR

HAZARDOUS ROOM (NFPA 101 §8.7)

INTERIOR EXIT LOCATION

EXTERIOR EXIT DISCHARGE

WALL TYPE LEGEND

HZ

3-HR. FIRE BARRIER

2-HR. FIRE/SMOKE BARRIER

1-HR. FIRE/SMOKE BARRIER

SMOKE BARRIER

SMOKE PARTITION

INTERIOR EXIT PASSAGEWAY

LIFE SAFETY LEGEND

1. BUILDING 8 CONTAINS HAZARDOUS MATERIALS, REFER

TO GI003.

INFECTION CONTROL

NOTES

1. ALL AREAS ON THIS PLAN SHALL BE CONSIDERED

CONSTRUCTION TYPE D, LOW RISK GROUP AND

INFECTION CONTROL PRECAUTION CLASS IV UNLESS

OTHERWISE NOTED.

ELECTRICAL

CO

RR

ID

OR

C8 -3

B

C8-3A

CONNECTING CORRIDOR

C8-3

TRUTH POINT

CO-ORDR

PATIENT

CENTERED CARE

PGM

SPECIALIST

OFFICE

(PATIENT

CENTERED

CARE)

PGM

MGR OFFICE

(PATIENT

CENTERED

CARE)

OFFICE

TEL

COPY RM

MENS

REST RM

WOMENS

REST RM

BREAK

RM

MOBILITY MGR

OFFICE VET

TRANSPORTATION

AND BENEFICIARY

TRAVEL

WARD

ADMIN

AOD (ADMIN

OF THE

DAY)

MED

RECORDS

TECH

OFFICE

NURSING

EDUCATION AND

RESEARCH

STAIROFFICE

(PATIENT

CENTERED

CARE)

223A

MGMT

AND PGM ANALYST

(PATIENT

CENTERED CARE)

OFFICE

OFFICE

OFFICE

OFFICE

TRANSPORTATION

CO-ORDR

OFFICE

MED

RECORDS

TECHNICIAN

OFFICE

RELEASE OF

INFO

(MED

RECORDS)

SUPV (MED

ADMIN

SPECIALIST)

BEREAVEMENT RM

CHIEF (NURSING

EDUCATION AND

RESEARCH) OFFICE

STORAGE

TRASH LINEN

203HAC

OFFICE

OFFICE

200E

OFFICE

200D 200C

OFFICE OF

ACADEMIC

AFFILIATION

200B

OFFICE

200A

OFFICE OF

ACADEMIC

AFFILIATION

CORRIDOR

STAIR

NO 3

ELECTRICAL

CLOSET

220A

220B

220C

200F

CO

RR

ID

OR

NURSING

EDUCATION AND

RESEARCH

EX

HZ

008.2.01

008.2.01

EX

HZ

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .