36C26118B0042-043.pdf

PDF 73 KB Posted

Attached to
Project No. 640-12-124P Renovate Canteen Plaza Bldg 101
Solicitation number
36C26118B0042
Issued by

About this file

36C26118B0042 102213.01 Wire Mesh Panel-100CD.pdf

View the file

Other files

File Type Posted
36C26118B0042-00008001.pdf PDF
36C26118B0042-00008000.docx DOCX document
36C26118B0042-00007000.docx DOCX document
36C26118B0042-00006001.pdf PDF
36C26118B0042-00006000.docx DOCX document
36C26118B0042-00005000.docx DOCX document
36C26118B0042-00004000.docx DOCX document
36C26118B0042-00003001.pdf PDF
36C26118B0042-00003000.docx DOCX document
36C26118B0042-00002000.docx DOCX document
36C26118B0042-00002002.docx DOCX document
36C26118B0042-00002001.pdf PDF
36C26118B0042-00001000.docx DOCX document
36C26118B0042-00001001.zip ZIP file
36C26118B0042-052.pdf PDF
36C26118B0042-035.pdf PDF
36C26118B0042-055.docx DOCX document
36C26118B0042-018.docx DOCX document
36C26118B0042-054.docx DOCX document
36C26118B0042-038.pdf PDF
36C26118B0042-032.pdf PDF
36C26118B0042-051.pdf PDF
36C26118B0042-031.pdf PDF
36C26118B0042-053.pdf PDF
36C26118B0042-047.pdf PDF
36C26118B0042-021.pdf PDF
36C26118B0042-016.docx DOCX document
36C26118B0042-028.docx DOCX document
36C26118B0042-019.docx DOCX document
36C26118B0042-049.pdf PDF
36C26118B0042-009.pdf PDF
36C26118B0042-010.pdf PDF
36C26118B0042-011.pdf PDF
36C26118B0042-003.pdf PDF
36C26118B0042-039.pdf PDF
36C26118B0042-014.docx DOCX document
36C26118B0042-023.docx DOCX document
36C26118B0042-033.pdf PDF
36C26118B0042-029.doc DOC document
36C26118B0042-044.pdf PDF
36C26118B0042-026.docx DOCX document
36C26118B0042-017.docx DOCX document
36C26118B0042-046.pdf PDF
36C26118B0042-041.pdf PDF
36C26118B0042-001.docx DOCX document
36C26118B0042-013.doc DOC document
36C26118B0042-034.pdf PDF
36C26118B0042-002.pdf PDF
36C26118B0042-027.docx DOCX document
36C26118B0042-006.pdf PDF
Show 40 more

Latest 50 of 69 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

RENOVATE CANTEEN PLAZA VA Project No. 640-12-124P Palo Alto, CA

VA Palo Alto Health Care System

10 22 13 - 1

SECTION 10 22 13.01

WIRE MESH PANELS

PART 1 - GENERAL

1.01 DESCRIPTION

This section covers stainless steel mesh panels complete with hardware.

1.02 RELATED WORK

A. Structural Steel Framing: Section 06 30 00

B. Schedule of Finishes: Section 09 06 00

1.03 APPLICABLE PUBLICATIONS

A. The publications listed below form a part of this specification to the extent referenced. The publications are referenced in the text by the basic designation also.

B. American Society for Testing and Materials (ASTM):

A36/36M-08 ............................... Carbon Structural Steel

1.4 SUBMITTALS

A. Submit in accordance with Section 01 33 23, SHOP DRAWINGS, PRODUCT DATA, AND SAMPLES.

B. Shop Drawings: Mesh panels, showing design, construction and materials.

C. Provide layout drawings with detailed erection drawings and specifications.

PART 2 - PRODUCTS

2.01 MATERIALS

A. Woven Wire Mesh : Halo™ 1162, Designer Series, Stainless Steel Type 304, 62% Open Area, Long Way of Opening Parallel to N/A, Sheet, 48.0000" Width x 96.0000" Length by McNICHOLS Quality or equal.

B. Steel Shapes, Plates and Bars: ASTM A36/36M.

1. Vertical Channel: 10 gauge, 2 inch leg U channel frame, stainless steel Type 304

2. Horizontal Channel: 10 gauge, 2 inch leg U channel frame, stainless steel Type 304,

3. Tabs: 3 ½ x 4 x 5/16 inch, stainless steel plates, Type 304

2.02 FABRICATION

A. Weld wire mesh to frame grind smooth and polish as necessary for a uniform finish.

B. Weld tabs to frame, grind smooth and polish as necessary for a uniform finish.

C. Frame corners to be mitered and free of sharp edges, grind smooth and polish as necessary for a uniform finish.

D. Finish: Stainless Steel type 304

RENOVATE CANTEEN PLAZA VA Project No. 640-12-124P Palo Alto, CA

VA Palo Alto Health Care System

10 22 13 - 2

PART 3 - EXECUTION

3.01 INSTALLATION

A. Erect the panels in accordance with the architectural drawings and detailed shop drawings.

B. Secure panels to each other and the Pavilion frame using mechanical fasteners.

3.02 ACCEPTANCE

A. Repair or replace damaged parts, touch-up abraded paint with matching paint.

B. Panels shall be level and firm. Adjust hardware to operate smoothly and securely.

- - - E N D OF SECTION- - -