36C26118B0042-043.pdf
PDF 73 KB Posted
- Solicitation number
- 36C26118B0042
About this file
36C26118B0042 102213.01 Wire Mesh Panel-100CD.pdf
View the file
Other files
Show 40 more
Latest 50 of 69 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
RENOVATE CANTEEN PLAZA VA Project No. 640-12-124P Palo Alto, CA
VA Palo Alto Health Care System
10 22 13 - 1
SECTION 10 22 13.01
WIRE MESH PANELS
PART 1 - GENERAL
1.01 DESCRIPTION
This section covers stainless steel mesh panels complete with hardware.
1.02 RELATED WORK
A. Structural Steel Framing: Section 06 30 00
B. Schedule of Finishes: Section 09 06 00
1.03 APPLICABLE PUBLICATIONS
A. The publications listed below form a part of this specification to the extent referenced. The publications are referenced in the text by the basic designation also.
B. American Society for Testing and Materials (ASTM):
A36/36M-08 ............................... Carbon Structural Steel
1.4 SUBMITTALS
A. Submit in accordance with Section 01 33 23, SHOP DRAWINGS, PRODUCT DATA, AND SAMPLES.
B. Shop Drawings: Mesh panels, showing design, construction and materials.
C. Provide layout drawings with detailed erection drawings and specifications.
PART 2 - PRODUCTS
2.01 MATERIALS
A. Woven Wire Mesh : Halo™ 1162, Designer Series, Stainless Steel Type 304, 62% Open Area, Long Way of Opening Parallel to N/A, Sheet, 48.0000" Width x 96.0000" Length by McNICHOLS Quality or equal.
B. Steel Shapes, Plates and Bars: ASTM A36/36M.
1. Vertical Channel: 10 gauge, 2 inch leg U channel frame, stainless steel Type 304
2. Horizontal Channel: 10 gauge, 2 inch leg U channel frame, stainless steel Type 304,
3. Tabs: 3 ½ x 4 x 5/16 inch, stainless steel plates, Type 304
2.02 FABRICATION
A. Weld wire mesh to frame grind smooth and polish as necessary for a uniform finish.
B. Weld tabs to frame, grind smooth and polish as necessary for a uniform finish.
C. Frame corners to be mitered and free of sharp edges, grind smooth and polish as necessary for a uniform finish.
D. Finish: Stainless Steel type 304
RENOVATE CANTEEN PLAZA VA Project No. 640-12-124P Palo Alto, CA
VA Palo Alto Health Care System
10 22 13 - 2
PART 3 - EXECUTION
3.01 INSTALLATION
A. Erect the panels in accordance with the architectural drawings and detailed shop drawings.
B. Secure panels to each other and the Pavilion frame using mechanical fasteners.
3.02 ACCEPTANCE
A. Repair or replace damaged parts, touch-up abraded paint with matching paint.
B. Panels shall be level and firm. Adjust hardware to operate smoothly and securely.
- - - E N D OF SECTION- - -
File details come from the government source that posted it.