RENOVATE CANTEEN PLAZA DVA Project No. 640-12-124P Palo Alto, CA VA Palo Alto Health Care System
SCHEDULE FOR FINISHES
09 06 00 - 1
SECTION 09 06 00
SECTION 09 06 00-SCHEDULE FOR FINISHES
VAMC: Palo Alto Health Care System
Location: 3801 Miranda Avenue, Palo Alto, California, 94304
Project no. and Name: 640-12-124P Renovate Canteen Plaza
Submission100%CD
Date: May 16, 2014
09 06 00 - 2
09 06 00 - 1
PART 1 – GENERAL
1.01 DESCRIPTION
A. This section contains a coordinated system in which requirements for materials specified in other sections shown are identified by abbreviated material names and finish codes in the room finish schedule or shown for other locations.
1.02 MANUFACTURERS
A. Manufacturer’s trade names and numbers used herein are only to identify colors, finishes, textures and patterns. Products of other manufacturer’s equivalent to colors, finishes, textures and patterns of manufacturers listed that meet requirements of technical specifications will be acceptable upon approval in writing by contracting officer for finish requirements.
1.03 SUBMITALS
A. Submit in accordance with SECTION 01 33 23, SHOP DRAWINGS, PRODUCT DATA, AND SAMPLES provide quadruplicate samples for color approval of materials and finishes specified in this section.
B. DIGITAL COLOR PHOTOS-EXTERIOR VIEWS:
Location Item/View to be Photographed
1.Upper Plaza As viewed from the canteen
2.Upper Plaza As viewed from the second floor of the B100/B101 bridge toward pavilions
3.Upper Plaza View of Glass Sculpture/water feature
4.Rose Garden View of “When you Wish” Sculpture from Patient drop-off near B100 looking toward Aquatic Building
5. Rose Garden View of “You my Butterfly” Sculpture from path looking toward the Rose Garden
6. Lower Plaza (Sensory Garden) View of the overall plaza as viewed from the patient drop-off of the polytrauma building looking toward the
RecServices Buildings
7. Lower Plaza (Sensory Garden) View of the bronze sculpture grouping-“Cone &
Sphere”
8. Lower Plaza (Sensory Garden) View of the bronze sculpture grouping- “Cone
Measuring Sphere"
9. Lower Plaza (Sensory Garden) View of the bronze sculpture grouping-“Kissing
Couple”
1.04 APPLICABLE PUBLICATIONS
A. Publications listed below form a part of this specification to the extent referenced. Publications are referenced in text by basic designation only.
B. MASTER PAINTING INSTITUTE: (MPI)
2001 ........................................... Architectural Painting Specification Manual
PART 2- PRODUCTS
2.01 DIGITAL COLOR PHOTOS
A. Size 24 x 35 mm.
B. Labeled for:
1. Location name.
2. View orientation
2.02 Division 32 - Site Improvements
A. SECTION 32 05 23, CEMENT AND CONCRETE FOR EXTERIOR IMPROVEMENTS
1. For Cement and Concrete for Exterior Improvements, Section 32 05 23 refer to specification section.
2222222 2222828739ehusdh;sedhf[yhw[408r2
09 06 00 - 3
222222222222222 22221
B. SECTION 32 13 20, SITE CONCRETE
1. For Site Concrete, Section 32 13 20 refer to specification section.
2.03 DIVISION 33 – SANITARY SEWER UTILITIES
A. SECTION 33 30 00, SANITARY SEWER UTILITIES
1. For Sanitary Sewer Utilities, Section 33 30 00 refer to specification section.
2.04 DIVISION 34 - SITE IMPROVEMENTS
A. SECTION 34 40 00, STORM DRAIN UTILITIES
1. For Storm Drain Utilities, Section 34 40 00 refer to specification section.
2.05 DIVISION 05 – METALS
A. SECTION 05 12 00, STRUCTURAL STEEL FRAMING
Component Finish Color
Pavilion - Frames Shop powder coated over HDG, Gloss Level 5 Semi-Gloss
Kelly Moore-Sierra White
B. SECTION 05 50 00, METAL FABRICATION
Item Finish
Pavilion-Wire Mesh Frames, Panel Channel Units Stainless Steel Type 304
09 06 00 - 4
Pavilion Panels - Wire Mesh Stainless Steel Type 304
09 06 00 - 5
2.06 DIVISION 06 WOOD, PLASTICS, AND COMPOSITES
A. SECTION 06 30 00, WOOD LOUVERS
WOOD LOUVERS
Location Finish
Upper Plaza Pavilions Ipe –prefinished penetrating oil all sides
2. 07 DIVISION 09 – FINISHES
A. SECTION 09 91 00, PAINT AND COATINGS
1. MPI Gloss and Sheen Standards Gloss @60 Sheen @85
Gloss Level 1 a traditional matte finish-flat max 5 units, and max 10 units
Gloss Level 2 a high side sheen flat-“a velvet-like” finish max 10 units, and 10-35 units
Gloss Level 3 a traditional “egg-shell like” finish 10-25 units, and 10-35 units
Gloss Level 4 a “satin-like” finish 20-35 units, and min. 35 units
Gloss Level 5 a traditional semi-gloss 35-70 units
Gloss Level 6 a traditional gloss 70-85 units
Gloss Level 7 a high gloss more than 85 units
09 06 00 - 6
2. 08 DIVISION 10 – SPECIALTIES
A. SECTION 10 22 13.01 / 10 13 00 / 10 14 00
1. Refer to specific specification sections.
B. SECTION 10 22 13.01, WIRE MESH PANELS
Location Finish
Upper Plaza-Pavilions S.S. Type 304
2. 09 DIVISION 12- FURNISHINGS
A. SECTION 12 93 00, SITE FURNISHINGS
1. For site furnishings refer to specification Section 12 93 00
09 06 00 - 7
2. 10 DIVISON 26 - ELECTRICAL
A. SECTION 26 56 00, SITE LIGHTING
Type and Component Exterior Finish Manufacturer Mfg. Name/No.
C, In-grade Manufacturer’s Polyester powder coat “Stealth Gray”
Kim
D, Step Lights Manufacturer’s powder coated Aluminum “Silver”
Bega Bega/2197
F, Pole Light and Pole Manufacturers standard finish – Silver (SLV)
Bega Pole Top Indirect Cutoff Optics- 8309MH- Pole-916HR
PART 3 EXECUTION
NOT USED
--- E N D OF SECTION---