SITE PLAN - AREA C
AS2.03
0 5 10 20 30
640-12-124P
3801 Miranda Ave. Palo Alto, CA 94304
RENOVATE CANTEEN PLAZA
BUILDING 101
MAY 16, 2014
A R C H I T E C T S
239 9TH STREET, SUITE 201 SAN FRANCISCO, CA 94103
T: (415) 682-7376 F: (415) 682-7339 www.meiarchitects.com
SB CK
NOTES:
1. SEE DRAWING AS1.00 FOR NOTES.
2. SEE LANDSCAPE, CIVIL, STRUCTURAL, AND
ELECTRICAL FOR DEMOLITION AND
CONSTRUCTION WORK.
ENLARGED FLOOR PLAN &
ROOF PLAN
AS4.01
2 FLOOR PLAN - CANOPY II, III, IV, V, IV
1/4" = 1'-0"
3 FLOOR PLAN - CANOPY I
1/4" = 1'-0"
7 ROOF PLAN - CANOPY I
1/4" = 1'-0"
10 ROOF PLAN - CANOPY II, III, IV, V, IV
1/4" = 1'-0"
640-12-124P
3801 Miranda Ave. Palo Alto, CA 94304
RENOVATE CANTEEN PLAZA
BUILDING 101
MAY 16, 2014
A R C H I T E C T S
239 9TH STREET, SUITE 201 SAN FRANCISCO, CA 94103
T: (415) 682-7376 F: (415) 682-7339 www.meiarchitects.com
SB CK
1'-0" 1'-0"2'-4"
THREAD RODS, SEE
DRILL AND TAP
BOTH RODS INTO
GALVANIZED STEEL BEAM
3'-4" 4'-4"
4'-4" 3'-4"
4'-4" 3'-4"
4'-4"
1'-0" 1'-0"1'-8"
1'-8"1'-0" 1'-0"
1'-0" 1'-0" 1'-8"
AS9.01
AS9.01 TYP. SIM.
TYP.
T Y
P
EQ EQ
11'-0"
3'-4"4'-4"2'-4"
T Y
P
11'-0"
TYP.
THREAD RODS, SEE
DRILL AND TAP
BOTH RODS INTO
OVERHEAD HSS
AS9.01
11'-0"
EQ EQ
INDICATES DIRECTION OF
LOUVER SLOPING DOWNWARD
11'-0"
EQ EQ
AS9.01 SIM. TYP.
T Y
P
TYP.
AS9.01
C
L
C
L
C
L
C
L
III II
VI
IV III/ II
VI V
GALVANIZED
STEEL
BEAM
WIRE MESH, TYP.
STONE VENEER
WALL, TYP.
BA
DC E67 5
7 56
V
B C
AS9.01 TYP.
AS9.01
TYP.
GALVANIZED
STEEL
COLUMN
AS9.01 TYP. SIM.
I
3'-0" 1'-8"2'-4"1'-0"
GALVANIZED STEEL BEAM
WIRE MESH, TYP.
STONE VENEER
WALL, TYP.
ED
GALVANIZED STEEL BEAM
AS9.01 TYP.
T Y
P
I
LOUVRES
4 3
AS9.01 TYP.
C
L
AS9.01 TYP.
AS9.01 TYP.
640-12-124P
3801 Miranda Ave. Palo Alto, CA 94304
RENOVATE CANTEEN PLAZA
BUILDING 101
MAY 16, 2014
A R C H I T E C T S
239 9TH STREET, SUITE 201 SAN FRANCISCO, CA 94103
T: (415) 682-7376 F: (415) 682-7339 www.meiarchitects.com
SB CK
AS8.01
TYPE
1/4" = 1'-0"
SCREEN TYPE AT ROOF
1/4" = 1'-0"
15 SCREEN TYPES AS VIEWED FROM
THE EXTERIOR SIDE OF PAVILIONS
TYPE
TYPE
TYPE TYPE
TYPE
TYPE
TYPE
ELEVATION AND SCREEN TYPES
1/4" = 1'-0"
1/4" = 1'-0"
CANOPY WEST ELEVATION
1/4" = 1'-0"
1/4" = 1'-0"
CANOPY WEST ELEVATION
1/4" = 1'-0"
1/4" = 1'-0"
3 CANOPY SOUTH ELEVATION
1/4" = 1'-0"
1/4" = 1'-0"
8 CANOPY NORTH ELEVATION
1/4" = 1'-0"
2 CANOPY SOUTH ELEVATION
1/4" = 1'-0"
CANOPY SOUTH ELEVATION5
1/4" = 1'-0" 1/4" = 1'-0"
4 CANOPY SOUTH ELEVATION
1/4" = 1'-0"
CANOPY SOUTH ELEVATION6
1'-1" 10"
10"
C
L
C
L
7'-8"
1'-4"3'-0"2'-4"1'-0"
C D E
C
L
C
L
C
L
C
L
C
L
C
L
7'-8"
1'-8" 3'-0" 2'-4" 8"
4"
TYP.
C
L
C
L
C
L
TYP.
TYP.
STEEL COLUMN, TYP. SEE
STRUCTURAL DRAWINGS
STEEL COLUMN, TYP. SEE
STRUCTURAL DRAWINGS
1'-1"
TYP. TYP.
C
L
CONC. SUPPORT FOR WIRE
MESH SCREEN.
COORDINATE EXACT
LOCATION &
REQUIREMENT WITH
SCREEN MANUFACTURER,
TYP.
EDGE OF CONC.FOOTING
BELOW
FACE OF CONC. PLANTER
WALL BELOW
PLANTER AREA, SEE
LANDSCAPE DRAWINGS,
TYP.
6" MIN. CLEAR BETWEEN
SLEEVES, TYP.
8" MAX. DIA. SLEEVE
THROUGH FOUNDATION,
COORDINATE EXACT
LOCATION OF DRAIN
CONNECTION
FACE OF STONE VENEER
WALL, SEE LANDSCAPE
DWG, TYP.
3"
TYP.
C
L
C
L
C
L
EDGE OF CONC.FOOTING
BELOW
EDGE OF CONC.
FOOTING BELOW
FACE OF STONE
VENEER WALL,
SEE LANDSCAPE
DWG., TYP.
10"
C
L
C
L
7'-8"
1'-4"3'-0"2'-4"1'-0"
E
D
C
L
1'-1"
4"
TYP.
C
L
C
L
C
L
1'-1"
FACE OF CONC. PLANTER
WALL BELOW
EDGE OF CONC.FOOTING
BELOW
C
L
1'-1" 1'-1"
10"
C
L
C
B
7'-8"
1'-4"3'-0"2'-4"1'-0"
4"
TYP.
C
L
C
L
C
L
C
L
C
L
EDGE OF CONC.FOOTING
BELOW
FACE OF CONC. PLANTER
WALL BELOW
EDGE OF CONC.FOOTING
BELOW
6" MIN., SEE L. DWG.
S E
E
L A
N D
S C
A P
E
4"
SEE L. DWG.
4" 1'-0"
NOTE: SEE LANDSCAPE DWG. FOR STONE CAP,
STONE VENEER, DOWEL PINS, PLANTER AREA
2'-6"
8" MAX DIA. SLEEVE
THROUGH
FOUNDATION
#5 TRANSVERSE BARS @ 12" O.C.
BARS CONFLICTING WITH THE
SLEEVES ARE TO BE RELOCATED
A MINIMUM OF 1 1/2" CLEAR OF
THE SLEEVE
4- #5 LONGITUDINAL BARS
STONE VENEER
#3 VERT. BARS @ 12" O.C.
WITH 1 1/2" CLEAR COVER. TYP.
3- #3 HORIZ. BARS WITH
1 1/2" CLEAR COVER. TYP.
EXTEND VERTICAL REINFORCE AND
EPOXY DOWEL INTO STONE 2" MIN.
PLANTER AREA
2'-2"
2'-6"
STONE VENEER WALL
#4 VERT. BARS @ 12"O.C.
3- #3 HORIZ. BARS WITH
1-1/2" CLEAR COVER. TYP.
NOTE: SEE LANDSCAPE DWG. FOR STONE CAP,
STONE VENEER WALL, DOWEL PINS, PLANTER AREA
CONCRETE
4 - #5 LONGITUDINAL BARS
#5 TRANSVERSE BARS @ 12" O.C.
4"
OPEN
10"
HSS COL., SEE S. DWG.
1" MAX., NON-SHRINK GROUT,
WRAP COLUMN BASE WITH
BITUMEN WATERPROOFING
MATERIAL & WATER STOP
SECOND CONCRETE POUR
NOTE: SEE LANDSCAPE DWG. FOR STONE CAP,
STONE VENEER WALL, DOWEL PINS, PLANTER
AREA. SEE STRUCTURAL DWG. FOR BASE PLATE
DETAIL
6" MIN., SEE L. DWG.
SEE L. DWG.
NOTE: SEE LANDSCAPE DWG. FOR STONE CAP,
STONE VENEER, DOWEL PINS, PLANTER AREA
2'-6"
8" MAX DIA. SLEEVE
THROUGH
FOUNDATION
#5 TRANSVERSE BARS @ 12" O.C.
BARS CONFLICTING WITH THE
SLEEVES ARE TO BE RELOCATED
A MINIMUM OF 1 1/2" CLEAR OF
THE SLEEVE
4- #5 LONGITUDINAL BARS
STONE VENEER
#3 VERT. BARS @ 12" O.C.
WITH 1 1/2" CLEAR COVER. TYP.
3- #3 HORIZ. BARS WITH
1 1/2" CLEAR COVER. TYP.
EXTEND VERTICAL REINFORCE AND
EPOXY DOWEL INTO STONE 2" MIN.
6"
1 1/2"2"
11 GA. STAINLESS STEEL PLATE, 4"X4"
11 GA. T-SHAPE STAINLESS STEEL
PLATE, 4"X4"
STAINLESS STEEL WIRE MESH
10 GA. STAINLESS STEEL SCREEN FRAME
1/4" Ø STAINLESS STEEL HILTI KB-3
ANCHORS WITH 2" EMBED @ 3" O.C.
BOLT, 7/16" DIA. W/ STD HOLE
3/16"
3/16"
FACE OF STONE VENEER WALLFACE OF STONE
VENEER WALL
640-12-124P
3801 Miranda Ave. Palo Alto, CA 94304
RENOVATE CANTEEN PLAZA
BUILDING 101
MAY 16, 2014
A R C H I T E C T S
239 9TH STREET, SUITE 201 SAN FRANCISCO, CA 94103
T: (415) 682-7376 F: (415) 682-7339 www.meiarchitects.com
SB CK
AS8.02
1" = 1'-0"
4 PLANTER AT STONE VENEER WALL
1" = 1'-0"
8 CONCRETE AT STONE VENEER WALL
1/2" = 1'-0"
3 PLAN - STONE VENEER WALL WITH PLANTER
@ CANOPY II, III, & IV
1/2" = 1'-0"
11 PLAN - STONE VENEER WALL WITH PLANTER PLAN
@ CANOPY I
1/2" = 1'-0"
9 PLAN - STONE VENEER WALL WITH PLANTER
@ CANOPY V & VI (SIM.)
1" = 1'-0"
12 COLUMN AT STONE VENEER WALL
STONE WALL SCHEDULE &
FOOTING DETAILS
1" = 1'-0"
17 CONCRETE AT STONE VENEER WALL
3" = 1'-0"
15 STEEL PLATE DETAIL
1/4" Ø STAINLESS STEEL THREADED
ROD @ CENTER OF LOUVER SPAN
COUPLING NUT TO STEEL BEAM
ON THE OPPOSITE END
DRILL AND TAP STEEL BEAM, TYP.
1" X 6" WOOD PLANK
STAINLESS STEEL JAMB NUT
STAINLESS NUT
GALV. STRUCTURAL STEEL BEAM
WITH POWDER COAT FINISH
C
L
STEEL
PLATE
3 1/2"
C
L
STEEL
PLATE
1" X 6" WOOD PLANK
7/16" Ø STAINLESS STEEL BOLT
WITH WASHER EACH SIDE
5" WIDE X 3 1/2" LONG 11 GA. GALV.
STEEL PLATE WITH POWDER COAT
FINISH, WELDED TO STEEL BEAM
GALV. STEEL BEAM BEYOND
C
L
STEEL
PLATE
C
L
STEEL
PLATE
T
Y
P
C
L
STEEL
PLATE
6"
C
L
GALV. STRUCTURAL STEEL BEAM WITH
POWDER COAT FINISH
5" WIDE X 3 1/2" LONG 11 GA. GALV.
STEEL PLATE WITH POWDER COAT
FINISH, WELD TO STRUCTURAL STEEL
COLUMN
1" X 6" WOOD PLANK
1/2" MAX1"
1/8"
1/8"
GALV. STRUCTURAL STEEL COLUMN
WITH POWDER COAT FINISH
STEEL
PLATE
M I N
STAINLESS STEEL WIRE MESH
10 GA. STAINLESS STEEL SCREEN
FRAME
5/16" THICK STAINLESS STEEL TAB
WELDED TO WIRE MESH FRAME
7/16" Ø STAINLESS STEEL BOLT IN
OVERSIZED HOLE WITH WASHER
EACH SIDE
5/16" THICK GR 50 GALV. STEEL
PLATE WITH POWDER COAT
FINISH, WELD TO STEEL BEAM
GALV. STRUCTURAL STEEL BEAM
WITH POWDER COAT FINISH
C
L
4"
3/16"
3/16"
STAINLESS STEEL WIRE MESH
GALV. STRUCTURAL STEEL BEAM WITH
POWDER COAT FINISH
5/16" THICK GR 50 GALV. STEEL PLATE
WITH POWDER COAT FINISH, WELD TO
STEEL BEAM
7/16" Ø STAINLESS STEEL BOLT IN
OVERSIZED HOLE WITH WASHER EACH
SIDE
10 GA. STAINLESS STEEL WIRE
MESH FRAME
5/16" THICK STAINLESS STEEL TAB
WELDED TO WIRE MESH FRAME
GALV. STRUCTURAL STEEL BEAM
WITH POWDER COAT FINISH
4"
REFER TO DETAIL 5/ AS 9.01
FOR SCREEN CONNECTION
AT ROOF
REFER TO DETAIL 7/AS 9.01
FOR LOUVRE CONNECTION
AT ROOF
3 1/2"
STRUCTURAL STEEL BEAM
BEYOND
C
L
STEEL
PLATE
C
L
STEEL
PLATE
3 1/2"
2 1/2"
10 GA. STAINLESS STEEL
SCREEN FRAME
5/16" PLATE WELDED TO
SCREEN FRAME
7/16" Ø STAINLESS STEEL BOLT IN
OVERSIZED HOLE WITH WASHER
ON EACH SIDE
5/16" THICK GR 50 GALV. STEEL PLATE
WITH POWDER COAT FINISH, WELD TO
STEEL BEAM
GALV. STRUCTURAL STEEL BEAM
WITH POWDER COAT FINISH
4"
2"
MIN.
C
L
STAINLESS STEEL WIRE MESH
4"
3/16"
3/16"
STAINLESS STEEL WIRE MESH
STAINLESS STEEL WIRE MESH
5/16" THICK STAINLESS STEEL TAB
WELDED TO WIRE MESH FRAME
7/16" Ø STAINLESS STEEL BOLT IN
OVERSIZED HOLE WITH WASHER EACH
SIDE
10 GA. STAINLESS STEEL WIRE
MESH FRAME
5/16" THICK STAINLESS STEEL TAB
WELDED TO WIRE MESH FRAME
1/4" Ø STAINLESS STEEL
THREADED ROD &NUTS@
CENTER OF WOOD PLANK SPAN
DRILL AND TAP STEEL BEAM
1" X 6" WOOD PLANK, TYP.
STAINLESS STEEL JAMB NUT
GALV. STRUCTURAL STEEL BEAM
WITH POWDER COAT FINISH
C
L
2 3/4"
STEEL
PLATE
C
L
STEEL
PLATE
1" X 6" WOOD PLANK
7/16" Ø STAINLESS STEEL BOLT
WITH WASHER EACH SIDE
5" WIDE X 3 1/2" LONG 11 GA.
GALV. STEEL PLATE WITH
POWDER COAT FINISH, WELDED
TO STEEL BEAM
GALV. STEEL COLUMN BEYOND
2 3/4"
C
LSTEEL
PLATE
T
Y
P
T Y
P
STEEL
PLATE
C
L
STEEL
PLATE
C
L
3" = 1'-0"
ROOF LOUVER CONNECTION @
STEEL BEAM
3" = 1'-0"
SECTION AT ROOF LOUVER AND
ROOF SCREEN
AS9.01
3" = 1'-0"
SECTIION @ SCREEN AND
STEEL BEAM CONNECTION
3" = 1'-0"
SCREEN CONNECTION @ STEEL
BEAM
3" = 1'-0"
THREADED ROD AT LOUVER
3" = 1'-0"
WOOD LOUVER CONNECTION
TO STEEL COLUMN
SCREEN TO SCREEN CONNECTION
3" = 1'-0"
3" = 1'-0"
SECTION @ ROOF SCREEN AND
STEEL BEAM CONNECTION
640-12-124P
3801 Miranda Ave. Palo Alto, CA 94304
RENOVATE CANTEEN PLAZA
BUILDING 101
MAY 16, 2014
A R C H I T E C T S
239 9TH STREET, SUITE 201 SAN FRANCISCO, CA 94103
T: (415) 682-7376 F: (415) 682-7339 www.meiarchitects.com
SB CK
DETAILS
3" = 1'-0"
VERTICAL LOUVER
3" = 1'-0"
10 VERTICAL LOUVER
640-12-124P
3801 Miranda Ave. Palo Alto, CA 94304
RENOVATE CANTEEN PLAZA
BUILDING 101
MAY 16, 2014
A R C H I T E C T S
239 9TH STREET, SUITE 201 SAN FRANCISCO, CA 94103
T: (415) 682-7376 F: (415) 682-7339 www.meiarchitects.com
SB CK
NTS
6 EN-11.04: PEDESTRIAN DIRECTIONAL SIGN - APPLICATION
NTS
EN-17.01: CAMPUS MAP SIGN - APPLICATION
NTS
14 EN-11.04: PEDESTRIAN DIRECTIONAL SIGN - GRAPHIC LAYOUT
NTS
EN-17.01: CAMPUS MAP SIGN - GRAPHIC LAYOUT
AG4.01
NTS
2 SIGNAGE TEXT
NTS
4 SIGNAGE COLORS
SIGN TYPE DETAILS
1 NOTES:
CONTRACTOR TO COORDINATE AND VERIFY ALL
TEXT, ICONS, SYMBOLS, GRAPHICS, COLORS, AND
FINISHES FOR EACH SIGN WITH COR PRIOR TO
FABRICATION. VERIFY EXACT LOCATIONS OF EACH
SIGN WITH COR PRIOR TO INSTALLATION.
SIGN TYPE DETAILS
AG4.02
640-12-124P
3801 Miranda Ave. Palo Alto, CA 94304
RENOVATE CANTEEN PLAZA
BUILDING 101
MAY 16, 2014
A R C H I T E C T S
239 9TH STREET, SUITE 201 SAN FRANCISCO, CA 94103
T: (415) 682-7376 F: (415) 682-7339 www.meiarchitects.com
SB CK
NTS
2 CONSTRUCTION SIGN
NTS
SAFETY SIGN
7. CHAMFER: 3/4 INCH ON EXPOSED CORNERS, U.N.O.
2. HOT ROLLED SHAPES AND PLATES 2" IN THICKNESS OR GREATER WITH FLANGES 1 1/2" IN
THICKNESS OR GREATER ARE TO HAVE A MINIMUM CHARPY V-NOTCH TEST VALUE OF 20
FOOT-POUNDS AT 70 DEGREES FAHRENHEIT.
3. HOT DIP GALVANIZE IN ACCORDANCE WITH ASTM A123 AND ASTM A153 STRUCTURAL
STEEL AND FASTENERS THAT ARE PERMANENTLY EXPOSED TO THE WEATHER.REPAIR
GALVANIZING AFTER WELDING IN ACCORDANCE WITH ASTM A780.
4. STRUCTURAL STEEL AND CONNECTIONS EXPOSED TO VIEW IN THE COMPLETED BUILDING
ARE DESIGNATED ARCHITECTURALLY EXPOSED STRUCTURAL STEEL (AESS).
5. ARC-WELDING ELECTRODES /FILLER METALS TO BE LOW HYDROGEN TYPES E7XTX,
E7XTXX OR E70XXX MINIMUM AS APPLICABLE. USE ELECTRODES WITH CHARPY V-
NOTCH TEST VALUES OF A MINIMUM OF 20 FOOT-POUNDS AT 0 DEGREES FAHRENHEIT
PER SECTION 7.3a OF AISC 341 WHERE DESIGNATED "CVN". USE ELECTRODES WITH
CHARPY V-NOTCH TEST VALUES OF A MINIMUM OF 20 FOOT POUNDS AT -20 DEGREES
FAHRENHEIT AND 40 FOOT POUNDS AT 70 DEGREES FAHRENHEIT WHERE DESIGNATED "DC"
6. WELDERS TO BE CERTIFIED BY AWS AND THE GOVERNING JURISDICTION.
7. WHERE FIELD WELDING IS NOTED, THE DESIGNATION IS GIVEN AS A SUGGESTED
CONSTRUCTION PROCEDURE ONLY.
8. PROVIDE NATURAL CAMBER UP, UNLESS NOTED OTHERWISE. EXCEPT AT CANTILEVERS. AT
CANTILEVERS PROVIDE CAMBER SUCH THAT TIP OF CANTILEVERS IS ABOVE FINAL
ELEVATION.
9. SPLICE MEMBERS ONLY WHERE INDICATED.
10. DETAIL, FABRICATE AND ERECT IN ACCORDANCE WITH AISC "SPECIFICATION FOR
STRUCTURAL STEEL FOR BUILDINGS", LATEST EDITION.
VI EXPANSION (WEDGE) ANCHORS
1. WEDGE ANCHORS INTO CONCRETE ARE TO HAVE BEEN TESTED & QUALIFIED FOR USE IN
CRACKED CONCRETE PER ACI355.2 & ICC-ER AC193. ANCHORS TO HAVE A CURRENT ICC-ES
REPORT APPROVED FOR CRACKED CONCRETE (SEISMIC DESIGN CATEGORIES A-F PER
SECTION 4.0 ICC REPORT) USE UNDER THE 2009 IBC. INSTALL ANCHORS IN ACCORDANCE
WITH ICC-ES REPORT AND MANUFACTURES INSTRUCTIONS.
2. PROVIDE STAINLESS STEEL FASTENERS FOR EXTERIOR USE OR WHEN EXPOSED TO
WEATHER.PROVIDE GALVANIZED CARBON STEEL ANCHORS AT OTHER LOCATIONS,
UNLESS OTHERWISE NOTED.
3. IF REINFORCEMENT IS ENCOUNTERED DURING DRILLING, ABANDON AND SHIFT THE
HOLE LOCATION TO AVOID THE REINFORCEMENT. PROVIDE A MINIMUM OF 2 ANCHOR
DIAMETERS OR 1 INCH, WHICHEVER IS LARGER, OF SOUND CONCRETE BETWEEN THE
DOWEL AND THE ABANDONED HOLE. FILL THE ABANDONED HOLE WITH NON-SHRINK
GROUT. IF THE ANCHOR OR DOWEL MAY NOT BE SHIFTED AS NOTED ABOVE, THE V.A.
RESIDENT ENGINEER WILL DETERMINE A NEW LOCATION.
4. LOCATE REINFORCEMENT AND CONFIRM FINAL ANCHOR LOCATIONS PRIOR TO
FABRICATING PLATES, MEMBERS, OR OTHER STEEL ASSEMBLIES ATTACHED WITH
MECHANICAL ANCHORS.
5. ANCHORS WILL BE PROOF-TESTED BY OWNER'S TESTING AND INSPECTION AGENCY.
6. IF ANY ANCHOR FAILS TESTING, REPLACE ANCHOR AND TEST ADDITIONAL ANCHORS OF
THE SAME CATEGORY NOT PREVIOUSLY TESTED UNTIL TWENTY (20) CONSECUTIVE
PASS, THEN RESUME INITIAL TESTING FREQUENCY.
7. APPLY TEST LOAD BY ANY METHOD THAT WILL EFFECTIVELY MEASURE THE TENSION ON
THE ANCHOR SUCH AS DIRECT PULL WITH A HYDRAULIC JACK, TORQUE WRENCH, OR
CALIBRATED SPRING-LOADING DEVICES, ETC.
8. TEST ANCHORS NO SOONER THAN 24 HOURS AFTER INSTALLATION.
IX DESIGN CRITERIA
1. APPLICABLE CODE: 2012 INTERNATIONAL BUILDING CODE WITH
DEPARTMENT OF VETERANS AFFAIRS H18-8 SEISMIC DESIGN
REQUIREMENTS DATED FEBRUARY 2011
2. SPREAD FOOTING
DL + LL = 3.5 KSF
DL + LL + (W OR EQ) = 4.6 KSF
3. GRAVITY LOADS:
A. DEAD LOADS - VARY BASED ON ACTUAL STRUCTURE.
B. VERTICAL DEFLECTION ON PERIMETER BEAMS DUE TO LIVE
LOAD:
LIVE LOADS: (REDUCIBLE PER CODE)
ROOF 20 PSF OR 300#
4. SEISMIC DESIGN:
SEISMIC RESPONSE COEFFICIENT: Cs = 1.05 ρ= 1.3
WHERE:R =
Ss= 1.96 S1= 0.827 Sds= 1.31 Sd1= 0.83
SEISMIC IMPORTANCE FACTOR: IE = 1.0
SITE CLASS: C
SEISMIC DESIGN CATEGORY: F
ANALYSIS PROCEDURE: EQUIVALENT LATERAL
FORCE ANALYSIS
DESIGN SEISMIC LATERAL DRIFT δ =
5. WIND DESIGN:
BASIC WIND SPEED = 100 MPH
WIND EXPOSURE = B
OCCUPANCY CATEGORY = II
I = 1.0
COMPONENTS & CLADDING:
ROOF CANOPY:
18.4 PSF
I GENERAL
1. MATERIALS AND WORKMANSHIP TO CONFORM WITH THE 2012 EDITION OF THE
INTERNATIONAL BUILDING CODE, WITH DEPARTMENT OF VETERANS AFFAIRS H18-8
AMENDMENTS AND THE REQUIREMENTS OF THE CONTRACT DOCUMENTS.
2. THESE GENERAL NOTES SUPPLEMENT THE REQUIREMENTS OF THE PROJECT
SPECIFICATIONS. IN CASE OF CONFLICT BETWEEN THE PLANS AND SPECIFICATIONS,
CONTACT THE V.A. RESIDENT ENGINEER.
3. REFERENCE TO CODES, RULES, REGULATIONS, STANDARDS, MANUFACTURER'S
INSTRUCTIONS OR REQUIREMENTS OF REGULATORY AGENCIES IS TO THE LATEST
PRINTED EDITION OF EACH IN EFFECT AT THE DATE OF SUBMISSION OF BID UNLESS
THE DOCUMENT DATE IS SHOWN.
4. VERIFY ALL DIMENSIONS, ELEVATIONS AND SITE CONDITIONS BEFORE STARTING
WORK. NOTIFY THE V.A. RESIDENT ENGINEER OF DISCREPANCIES.
5. REFER TO ARCHITECTURAL AND CIVIL DRAWINGS FOR SITE SLABS AND WALLS.
6. DRAWINGS INDICATE GENERAL AND TYPICAL DETAILS OF CONSTRUCTION. WHERE
CONDITIONS ARE NOT SPECIFICALLY INDICATED BUT ARE OF SIMILAR CHARACTER TO
DETAILS SHOWN, USE SIMILAR DETAILS OF CONSTRUCTION, SUBJECT TO REVIEW BY
THE V.A. RESIDENT ENGINEER.
7. DETAILS TITLED "TYPICAL" APPLY TO SITUATIONS OCCURRING ON
THE PROJECT THAT ARE THE SAME OR SIMILAR TO THOSE SPECIFICALLY
REFERENCED. SUCH DETAILS ARE NOT NOTED AT EACH LOCATION THAT THEY OCCUR.
8. THE CONTRACTOR IS RESPONSIBLE FOR COORDINATING THE WORK OF ALL TRADES
AND FOR CHECKING DIMENSIONS. NOTIFY THE V.A. RESIDENT ENGINEER OF ANY
DISCREPANCIES AND RESOLVE BEFORE PROCEEDING WITH THE WORK.
9. DO NOT SCALE THE DRAWINGS.
10. PROVIDE MEASURES NECESSARY TO PROTECT THE STRUCTURE DURING
CONSTRUCTION. SUCH MEASURES INCLUDE, BUT MAY NOT BE LIMITED TO, BRACING
AND SHORING FOR LOADS DURING CONSTRUCTION. RETAIN A REGISTERED CIVIL
ENGINEER WHOM IS PROPERLY QUALIFIED TO DESIGN BRACING, SHORING, ETC.
VISITS TO THE SITE BY THE V.A. RESIDENT ENGINEER WILL NOT INCLUDE OBSERVATION
OF THE ABOVE NOTED ITEMS.
11. INFORMATION SHOWN ON THE DRAWINGS RELATED TO EXISTING CONDITIONS
REPRESENTS THE PRESENT KNOWLEDGE, BUT WITHOUT GUARANTEE OF ACCURACY.
REPORT CONDITIONS THAT CONFLICT WITH THE CONTRACT DOCUMENTS TO THE
V.A. RESIDENT ENGINEER. DO NOT DEVIATE FROM THE CONTRACT DOCUMENTS
WITHOUT WRITTEN DIRECTION FROM THE V.A. RESIDENT ENGINEER.
12. CONSTRUCTION LOADS: EVENLY DISTRIBUTE STORED MATERIALS ON FLOORS AND
ROOFS DO NOT TO EXCEED ALLOWABLE LOADING FOR SUPPORTING MEMBERS AND
CONNECTIONS.
II FOUNDATION AND SITE WORK
1. THE DESIGN OF THE FOUNDATION SYSTEM IS BASED UPON THE CRITERIA AND
RECOMMENDATIONS CONTAINED IN THE GEOTECHNICAL INVESTIGATION REPORT
ENTITLED "GEOTECHNICAL INVESTIGATION AMBULATORY CARE POLYTRAUMA AND BLIND
REHABILITATION CENTERS VETERANS AFFAIRS MEDICAL CENTER, PALO ALTO,
CALIFORNIA, DATED 29 AUGUST 2011.
2. LOCATE AND PROTECT EXISTING UTILITIES TO REMAIN DURING AND/OR AFTER
CONSTRUCTION.
3. REMOVE ABANDONED FOOTINGS, UTILITIES, ETC. WHICH INTERFERE WITH NEW
CONSTRUCTION, UNLESS OTHERWISE INDICATED.
4. NOTIFY THE V.A. RESIDENT ENGINEER IF ANY BURIED STRUCTURES NOT
INDICATED, SUCH AS CESSPOOLS, CISTERNS, FOUNDATIONS, ETC., ARE FOUND.
5.. THE CONTRACTOR IS SOLELY RESPONSIBLE FOR EXCAVATION PROCEDURES
INCLUDING LAGGING, SHORING, UNDERPINNING AND PROTECTION OF EXISTING
CONSTRUCTION.
6. REMOVE LOOSE SOIL AND STANDING WATER FROM FOUNDATION EXCAVATIONS
PRIOR TO PLACING CONCRETE.
III REINFORCING STEEL
1. REINFORCING TO CONFORM TO THE FOLLOWING, UNLESS OTHERWISE NOTED:
IV CAST-IN-PLACE CONCRETE
1. CONCRETE IS REINFORCED AND CAST-IN-PLACE UNLESS OTHERWISE NOTED. WHERE
REINFORCING IS NOT SPECIFICALLY SHOWN OR WHERE DETAILS ARE NOT GIVEN, PROVIDE
REINFORCING SIMILAR TO THAT SHOWN FOR SIMILAR CONDITIONS, SUBJECT TO REVIEW BY
THE V.A. RESIDENT ENGINEER.
2. ROUGHEN CONCRETE SURFACES OF CONSTRUCTION JOINTS TO 1/4 INCH AMPLITUDE AND
CLEAN OF LAITANCE, FOREIGN MATTER, AND LOOSE PARTICLES. LOCATE CONSTRUCTION
JOINTS AS SHOWN ON THE DRAWINGS. SUBMIT ALTERNATE JOINT LOCATIONS OR JOINTS
NOT SHOWN TO THE V.A. RESIDENT ENGINEER FOR REVIEW AND APPROVAL PRIOR TO
PROCEEDING WITH THE WORK.
3. AT LOCATIONS WHERE CONCRETE IS CAST AGAINST EXISTING CONCRETE, ROUGHEN
CONTACT SURFACES TO 1/4 INCH AMPLITUDE AND CLEAN OF LAITANCE, FOREIGN MATTER,
AND LOOSE PARTICLES.
4. CONCRETE CLEAR COVER TO REINFORCING BARS IS AS FOLLOWS, UNLESS OTHERWISE
NOTED:
6. CONCRETE TYPES U.O.N:
LOCATIONS TYPE
REINFORCING STEEL #8 AND LARGER AND
REINFORCING STEEL TO BE WELDED
REINFORCING STEEL #7 AND SMALLER
WELDED STEEL WIRE FABRIC
ASTM A706, 60 KSI
ASTM A615, 60 KSI
ASTM A185, 70 KSI
LOCATIONS CLEAR COVER
CONCRETE PLACED AGAINST EARTH 3 INCHES
FORMED SURFACES EXPOSED TO WEATHER
OR IN CONTACT WITH EARTH:
#5 BARS AND SMALLER
#6 BARS AND LARGER
1 1/2 INCHES
2 INCHES
CLASS
28 DAY F'c
(PSI)
TYPE LOCATION
A 4000 NORMAL WEIGHT
GRADE BEAMS, FOUNDATIONS,
DRILLED PIERS
SECTIONS TYPE
ROLLED SHAPES
WIDE FLANGES
CHANNELS, ANGLES, & OTHER
ASTM A992, GR 50
ASTM A36
PLATES
COLUMN BASE PLATES
COLUMN CONTINUITY PLATES
BEAM STIFFENER PLATES
OTHER, U.O.N.
ASTM A572, GR 50
ASTM A572, GR 50
ASTM A36
ASTM A572, GR 50
STEEL PIPE ASTM A53, GRADE B
COLD FORMED HOLLOW STRUCTURAL SECTION (HSS) ASTM A500, GRADE B
STAINLESS STEEL SHAPES, PLATES AND BARS
BOLTS
ASTM A276
ASTM A325X
MACHINE BOLTS ASTM A307
ANCHOR RODS ASTM F1554, GRADE 55
NUTS FOR BOLTS AND MACHINE BOLTS ASTM A563
HARDENED WASHERS ASTM F436
9. REACTION LOADS FROM TEST FIXTURES MAY BE APPLIED CLOSE TO THE ANCHOR BEING
TESTED, PROVIDED THE ANCHOR IS NOT RESTRAINED FROM WITHDRAWING BY A
BASEPLATE OR OTHER FIXTURE. IF RESTRAINT IS FOUND, LOOSEN AND SHIM OR REMOVE
THE FIXTURE PRIOR TO TESTING.
10. TEST 50% WEDGE ANCHORS PER ONE OF THE FOLLOWING METHODS:
A. HYDRAULIC RAM METHOD: APPLY PROOF TEST LOAD WITHOUT REMOVING THE
NUT. IF IT IS NOT POSSIBLE TO TEST WITH THE NUT INSTALLED, REPLACE THE
NUT WITH A THREADED COUPLER TO THE SAME TORQUE MEASURED WITH A
TORQUE WRENCH, AND THEN APPLY THE LOAD. ANCHOR IS ACCEPTABLE IF NO
MOVEMENT IS OBSERVED AT THE TEST LOAD. MOVEMENT MAY BE DETERMINED
WHEN THE WASHER UNDER THE NUT BECOMES LOOSE.
B. TORQUE WRENCH METHOD: TEST ANCHORS TO THE TORQUE LOAD
INDICATED IN THE TABLE BELOW WITHIN ONE HALF TURN OF THE NUT.
11. TEST ANCHORS TO THE FOLLOWING PROOF LOADS.
ANCHOR DIAMETER TENSION LOAD
(LBS)
TORQUE LOAD
(FT-LBS)
3/8"
1/2"
5/8"
3/4"
3/4"
VII ADHESIVE ANCHORS AND DOWELS
1. ANCHORS AND DOWELS INSTALLED INTO CONCRETE:
ANCHORS ARE TO HAVE BEEN TESTED & QUALIFIED FOR USE IN CRACKED CONCRETE
PER ACI355.2 & ICC-ES AC308. ANCHORS TO HAVE A CURRENT ICC-ES REPORT
APPROVED FOR CRACKED CONCRETE (SEISMIC DESIGN CATEGORIES A-F PER SECTION
4.0 OF ICC REPORT) USE UNDER THE 2009 IBC. INSTALL ANCHORS IN ACCORDANCE
WITH THE ICC-ES REPORT & MANUFACTURES INSTRUCTIONS.
2. EMBEDMENT DEPTH FOR ANCHORS AND DOWELS IS AS FOLLOWS, UNLESS
OTHERWISE NOTED. THE TESTING LABORATORY WILL PERFORM TENSION TESTS ON
50% OF ANCHORS AND DOWELS TO THE FOLLOWING TEST LOADS:
ANCHOR DIAMETER EMBEDMENT TENSION LOAD BASE MATERIAL
1/2"
1/2"
5/8"
3/4"
7/8"
1"
3"
6 1/2"
8"
10"
12"
14"
CONCRETE
CONCRETE
CONCRETE
CONCRETE
CONCRETE
CONCRETE
1832#
5217#
7802#
11,199#
12,206#
15,038#
3. ANCHORS: ASTM A36 THREADED RODS WITH ASTM A 563 GRADE A NUTS AND
ANSI B18.22.1 TYPE A WASHERS, UNLESS OTHERWISE NOTED. ANCHORS
DESIGNATED AS ASTM A193 GRADE B7 THREADED RODS TO USE ASTM A 563
GRADE DH HEAVY HEX NUTS AND ASTM F 436 WASHERS.
4. DOWELS: ASTM A615 GRADE 60 REINFORCING STEEL.
5. REMOVE GREASE, OIL, RUST, AND OTHER LAITANCE FROM RODS AND
DOWELS PRIOR TO INSTALLATION.
6. REPLACE ANCHORS AND DOWELS THAT FAIL DURING TESTING AND RETEST. IF
MORE THAN 10% OF THE TESTED DOWELS AND ANCHORS FAIL TO ACHIEVE
THE SPECIFIED TEST LOAD, TEST 100% OF THE DOWELS AND ANCHORS
INSTALLED IN THE LAST 2 DAYS OF ANCHOR INSTALLATION.
7. PREPARE HOLES AND INSTALL ANCHORS PER THE MANUFACTURER & ICC-ES
REPORT INSTRUCTIONS.
8. IF REINFORCEMENT IS ENCOUNTERED DURING DRILLING, ABANDON AND
SHIFT THE HOLE LOCATION TO AVOID THE REINFORCEMENT. PROVIDE A
MINIMUM OF 2 ANCHOR DIAMETERS OR 1 INCH, WHICHEVER IS LARGER, OF
SOUND CONCRETE BETWEEN THE DOWEL AND THE ABANDONED HOLE. FILL
THE ABANDONED HOLE WITH NON-SHRINK GROUT. IF THE ANCHOR OR
DOWEL MAY NOT BE SHIFTED AS NOTED ABOVE, THE V.A. RESIDENT
ENGINEER WILL DETERMINE A NEW LOCATION.
9. LOCATE REINFORCEMENT AND CONFIRM FINAL ANCHOR LOCATIONS PRIOR
TO FABRICATING PLATES, MEMBERS, OR OTHER STEEL ASSEMBLIES
ATTACHED WITH ADHESIVE ANCHORS.
VIII STRUCTURAL TESTS, INSPECTIONS, AND OBSERVATIONS
1. AN INDEPENDENT TESTING AGENCY AND SPECIAL INSPECTORS WILL BE
RETAINED BY THE OWNER TO PERFORM TESTS AND INSPECTIONS IN
ACCORDANCE WITH THE APPROVED TESTING, INSPECTION AND
OBSERVATION PROGRAM. PROVIDE ACCESS AND FURNISH SAMPLES TO THE
AGENCY AS REQUIRED BY THE CONTRACT DOCUMENTS.
2. IF INITIAL TESTS OR INSPECTIONS MADE BY THE OWNER'S TESTING AGENCY
REVEAL THAT ANY PORTION OF THE WORK DOES NOT COMPLY WITH THE
CONTRACT DOCUMENTS, ADDITIONAL TESTS, INSPECTIONS, AND
NECESSARY REPAIRS WILL BE MADE AT THE CONTRACTOR'S EXPENSE.
GENERAL NOTES:
V STRUCTURAL STEEL
1. STRUCTURAL STEEL TO CONFORM TO THE FOLLOWING UNLESS OTHERWISE NOTED:
3. THE FOLLOWING ITEMS REQUIRE TESTS & INSPECTIONS IN ACCORDANCE
WITH THE REQUIREMENTS OF THE CHAPTER "STRUCTURAL TESTS &
INSPECTIONS" OF THE 2012 INTERNATIONAL BUILDING CODE. ADDITIONAL
ITEMS AND REQUIREMENTS FOR TESTS & INSPECTIONS ARE IDENTIFIED IN
THE SPECIFICATIONS.
A. REINFORCING STEEL
B. FOUNDATIONS.
C. CONCRETE
D. STRUCTURAL STEEL
E. WELDING
F. POST-INSTALLED ANCHORS
4. NOTIFY THE V.A. RESIDENT ENGINEER AT SIGNIFICANT
CONSTRUCTION STAGES 72 HOURS IN ADVANCE & PROVIDE
ACCESS FOR THE FOLLOWING STRUCTURAL OBSERVATIONS:
A. FOUNDATIONS
1. REINFORCEMENT
B. STEEL FRAMING
1. GENERAL
6. DESIGN TEAM
JAMES O MALLEY SENIOR PRINCIPAL
ROBERT GRAFF PRINCIPAL IN CHARGE
CJ HORN DESIGNER
KEN MARTIN SENIOR CAD SPECIALIST
2. ACCURATELY POSITION, SUPPORT, AND SECURE REINFORCEMENT FROM DISPLACING DUE
TO FORMWORK, CONSTRUCTION, OR CONCRETE PLACEMENT OPERATIONS. LOCATE AND
SUPPORT REINFORCING BY METAL CHAIRS, RUNNERS, BOLSTERS, SPACERS, AND
HANGERS AT A MAXIMUM 3-FOOT SPACING.
3. TERMINATE REINFORCING STEEL IN STANDARD HOOKS, UNLESS OTHERWISE SHOWN.
4. PROVIDE REINFORCING SHOWN OR NOTED CONTINUOUS IN LENGTHS AS LONG AS
PRACTICABLE.
MINIMUM EMBEDMENT
DEPTH (IN.)
3 1/8
3 3/4
4 3/4
1/2" 3790 403 1/4
5/8" 5250 604
DOWEL SIZE
#4
#4
#5
#6
#7
#8
DEGENKOLB ENGINEERS
235 Montgomery Street, Suite 500
San Francisco, CA 94104
415.392.6952 PHONE
415.981.3157 FAX N
Drawing Title
Approved: Project Director
Project Title
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
Dwg. ofRevisions: Date
CONSULTANTS:
3801 MIRANDA AVE. PALO ALTO, CA 94304
ARCHITECT/ENGINEERS:
Office of Facilities
Management
MAY 5, 2017
o n e e ig h th in c h o n e fo o t
B
A
C
D
E
F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
VA FORM 08-6231, OCT 1978
1 2 3 4 5 6 87 9
F
E
D
C
B
A
97 8654321
T (415) 682-7376 F (415) 682-7339
239 9TH STREET, SUITE 201
SAN FRANCISCO, CA 94103
640-12-124P www.meiarchitects.com
KEY PLAN
4/25/2017 8:28:59 AM
GENERAL NOTES RENOVATE CANTEEN PLAZA
BUILDING 101
KAJ IW
SS0-1
ryanngo Rectangle ryanngo Text Box
CONTRACTOR'S
EXISTING
NEW
NUMBER
AND
AT
ADHESIVE ANCHOR
ANCHOR BOLT
ABOVE
ADDITIONAL
ADJACENT
AGGREGATE
ALUMINUM
ALTERNATE
AMERICAN NATIONAL STANDARDS INSTITUTE
APPROXIMATE
ANCHOR RODS
ARCHITECTURAL
AMERICAN SOCIETY for TESTING and MATERIALS
AMERICAN WIRE GAUGE
BETWEEN
BUILDING
BLOCKING
BEAM, BEAMS
BOUNDARY NAILING
BOTTOM OF FOOTING
BOTTOM
BEARING
BASEMENT
BOTH SIDES
CHANNEL
CAST IN PLACE
CONTROL JOINT
CENTERLINE
CEILING
CLEAR
CONCRETE MASONRY UNIT
COLUMN
CONCRETE
CONNECTION
CONSTRUCTION
CONTINUOUS
COUNTERSINK
COMPLETE PENETRATION
CENTER
DOUBLE
DEMAND CRITICAL WELD
DECK or DECKING
DEMOLITION
DETAIL, DETAILS
DIAGONAL
DIAMETER
DIMENSION, DIMENSIONS
DISTANCE
DOWN
DITTO
DOWEL, DOWELS
DRAWING, DRAWINGS
EXPANSION ANCHOR
EACH
EACH FACE
EACH SIDE
EACH WAY
ELECTRICAL
ELEVATION
ELEVATOR
EMBEDMENT
EDGE NAILING
EDGE OF CONCRETE PANEL
EDGE OF SLAB
EQUAL
EQUIPMENT
EXPANSION JOINT
EVERY
EXCAVATION
EXPANSION
EXTERIOR
FAR FACE
FOUNDATION
FINISH
FLOOR, FLOORS
FIELD NALING
FACE OF
FACE OF CONCRETE
FACE OF CONCRETE PANEL
FACE OF STUDS
FIREPROOFING
FAR SIDE
FOOT OR FEET
FOOTING, FOOTINGS
GAUGE
GALVANIZED
GLASS OR GLAZING
GROUND
GRADE
GYPSUM BOARD
HOLD DOWN
HOT DIPPED GALVANIZED
HEADER
HIGH POINT
HIGH STRENGTH BOLTS
HOLLOW STRUCTURAL STEEL
HEIGHT
HOOKS
HORIZONTAL
INSIDE DIAMETER
INFORMATION
JOIST, JOISTS
JOINT
KNOCK-OUT
ANGLE
DEVELOPMENT LENGTH
HOOK DEVELOPMENT LENGTH
LOW POINT
LEVEL
LONG LEG VERTICAL
LONG LEG HORIZONTAL
LOCATION
LONGITUDINAL
LAP SPLICE LENGTH
LIGHTWEIGHT CONCRETE
MAXIMUM
MACHINE BOLT
MEZZANINE
MECHANICAL
MECHANICAL, ELECTRICAL, PLUMBING DOCUMENTS
METAL
MANUFACTURER
MINIMUM
MISCELLANEOUS
MOUNTED
NORTH
NEAR FACE
NOT IN CONTRACT
NEAR SIDE
NOT TO SCALE
NUMBER
NOMINAL (DIAMETER)
NORMAL WEIGHT CONCRETE
ON CENTER
OUTSIDE DIAMETER
OPPOSITE HAND
OPENING
OPPOSITE
STANDARD STEEL PIPE W/ # DIA.
X-STRONG STEEL PIPE W/ # DIA.
XX-STRONG STEEL PIPE W/ DIA.
PANEL IDENTIFICATION
PIECE, PIECES
PERPENDICULAR
PANEL JOINT
PLATE
PARTIAL PENETRATION
PAIR
POINT
PARTITION
ROUGH OPENING
RADIUS
REINFORCING BAR
REFERENCE
REINFORCED or REINFORCING
REQUIRED
REVISE or REVISION
ROOFING
ROLLED STEEL JOIST
SEE ARCH DOCUMENTS
SCHEDULE
SECTION
SHEET
SHEATHING
SIMILAR
SLOPE
SEISMIC LOAD RESISTING SYSTEM
SHEET METAL SCREW
SLAB ON GRADE
SPECIFICATION
SPECIFICATIONS
SQUARE
STAINLESS STEEL
STAGGER or STAGGERED
STANDARD
STIFFENER
STIRRUP or STIRRUPS
STEEL
STRUCTURAL
SUBSTITUTE
SUSPENDED
SYMMETRICAL
TOP and BOTTOM TONGUE and GROOVE
THICK
THREADED
THROUGH
TOP OF
TOP OF STEEL
TOP OF STRUCTURAL SLAB
TREAD
TUBE STEEL
TYPICAL
UNLESS OTHERWISE NOTED
UNREINFORCED MASONRY
VENTILATE
VERTICAL
VERIFY IN FIELD
WIDE FLANGE
WITH
WITHOUT
WOOD
WORK POINT
WEIGHT
WELDED WIRE MESH
EXTRA HEAVY
DOUBLE EXTRA HEAVY
EXTRA STRONG
DOUBLE EXTRA STRONG
ABBREVIATIONS
(E) (N) A.A.
A.B.
ABV
ADDL
ADJ.
AGGR.
AL.
ALT.
ANSI
APPROX.
A.R.
ARCH.
ASTM
AWG
BET.
BLDG
BLKG
BM, BMS
B.N.
B.O.F.
BOT.
BRG
BSMT
B.S.
C C.I.P.
C.J.
CL
CLG
CLR
CMU
COL.
CONC.
CONN.
CONSTR.
CONT.
CSK
CP
CTR
DBL.
DC
DK, DKG
DEMO.
DET., DETS
DIAG.
DIA. or Ø
DIM., DIMS
DIST.
DN
do
DWL, DWLS
DWG, DWGS
E.A.
EA.
E.F.
E.S.
E.W.
ELEC.
EL.
ELEV.
EMBED.
E.N.
E.O.P.
E.O.S.
EQ.
EQUIP.
E.J.
EV.
EXCAV.
EXP.
EXT.
F.F.
FDN
FIN.
FLR., FLRS
F.N.
F.O.
F.O.C.
F.O.P.
F.O.S.
FP.
F.S.
FT
FTG, FTGS
GA.
GALV.
GL.
GRND
GR.
GYP. BD.
H.D.
H.D.G.
HDR
H.P.
HSB
HSS
HT
HK, HKS
HORIZ., (H)
I.D.
INFO.
JST, JSTS
JT
K.O.
L ld ldb L.P.
LEV.
LLV
LLH
LOC.
LONGIT.
ls
LWC
MAX.
M.B.
MEZZ.
MECH.
M.E.P.
MTL
MFR
MIN.
MISC.
MTD.
N N.F.
N.I.C.
N.S.
N.T.S.
NO. OR #
NOM.
NWC
O.C.
O.D.
O.H.
OPNG
OPP.
P#
PX#
PXX#.
PANEL " "
PC., PCS.
PERP.
P.J.
PL
PP
P
PT
PTN
R.O.
R or RAD.
REBAR
REF.
REINF.
REQ'D
REV.
RFG
RSJ
S.A.D.
SCHED.
SECT.
SHT
SHTG
SIM.
SL.
SLRS
SMS
S.O.G.
SPEC.
SPECS.
SQ.
SS
STAGG.
STD
STIFF.
STIR.
STL
STRUC.
SUBST.
SUSP.
SYM.
T&B T&G
THK
THRD
THRU
T.O.
T.O.S.
T.O.SLAB
TR.
TS
TYP.
U.O.N.
URM
VENT.
VERT., (V)
V.I.F.
W or WF W/ W/O
WD
W.P.
WT
WWM
X HVY.
XX HVY.
X STR.
XX STR.
REFERENCE SYMBOLS
DETAIL/SECTION
SECTION NUMBER
LINE OF SECTION CUT
DIRECTION OF VIEW
S3.1
DETAIL
DETAIL PLAN OR ELEVATION
SINGLE ELEVATION
GRID LINES
LEVEL LINE
WORK POINT
REVISION
PLAN SYMBOLS
COLUMNS
DRAWING SHEET NUMBER,
HYPHEN INDICATES SAME
SHEET
S5.2
DETAIL NUMBER
DRAWING SHEET NUMBER,
HYPHEN INDICATES SAME
SHEET
LINE OF SECTION CUT
DIRECTION OF VIEW
S6.3 AREA OF DETAIL
S5.1
AREA OF ENLARGED
PLAN OR ENLARGED
ELEVATION
DIRECTION OF VIEW
ELEVATION NUMBER
A
SECOND FLOOR
EL. 123'-0"
INDICATES HEIGHT ABOVE
DATUM
W.P.
WORK POINT OF CONNECTION,
POINT WHERE FORCES ARE
RESOLVED
REVISION NUMBER-
SEE REVISION HISTORY ON
TITLE BLOCK OF EACH SHEET
WIDE-FLANGE COLUMN, SEE
COLUMN SCHEDULE
TUBE COLUMN, SEE COLUMN
SCHEDULE
MATERIAL SYMBOLS
STEEL
CONCRETE
EARTH
S3.1
DRAWING SHEET NUMBER,
HYPHEN INDICATES SAME
SHEET
BEAM DESIGNATIONS
W16X31 [22]
(-4 1/2") <3/4">
BEAM SIZE
INDICATES NO. SHEAR STUDS
TOP OF STEEL RELATIVE
TO REFERENCE ELEVATION
INDICATES BEAM CAMBER
DEGENKOLB ENGINEERS
235 Montgomery Street, Suite 500
San Francisco, CA 94104
415.392.6952 PHONE
415.981.3157 FAX N
Drawing Title
Approved: Project Director
Project Title
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
Dwg. ofRevisions: Date
CONSULTANTS:
3801 MIRANDA AVE. PALO ALTO, CA 94304
ARCHITECT/ENGINEERS:
Office of Facilities
Management
MAY 5, 2017
o n e e ig h th in c h o n e fo o t
B
A
C
D
E
F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
VA FORM 08-6231, OCT 1978
1 2 3 4 5 6 87 9
F
E
D
C
B
A
97 8654321
T (415) 682-7376 F (415) 682-7339
239 9TH STREET, SUITE 201
SAN FRANCISCO, CA 94103
640-12-124P www.meiarchitects.com
KEY PLAN
4/25/2017 8:29:00 AM
ABBREVIATIONS & SYMBOLS RENOVATE CANTEEN PLAZA
BUILDING 101
RMG KLM
SS0-2
D E
11' - 6"
F1
F2F1
SS0-5
SS0-5
TYP.
TYP.
SS0-4
D E
11' - 6"
HSS6X6X5/16
H S
S 6X
2X 1/
H S
S 6X
6X 5/
HSS6X6X5/16
H S
S 6X
6X 5/
HSS6x6x5/16
COL., TYP.
MITERED
G
SS0-4
SS0-5
TYP.
SS0-5
EA. END
A B DC E
11' - 6" 11' - 6" 11' - 6" 11' - 6"
F1 F2
F1
F1
F2 F2 F2
F1F1
SS0-4
SS0-4
SIM.
SS0-5
TYP.
SS0-5
TYP.
A B DC E
11' - 6" 11' - 6" 11' - 6" 11' - 6"
HSS6X6X5/16 HSS6X6X5/16
HSS6X2X1/4 HSS6X2X1/4
HSS6X6X5/16 HSS6X6X5/16 HSS6X6X5/16
HSS6X6X5/16 HSS6X6X5/16 HSS6X6X5/16
H S
S 6X
6X 5/
H S
S 6X
6X 5/
HSS6X6X5/16
H S
S 6X
6X 5/
H S
S 6X
6X 5/
H S
S 6X
6X 5/
HSS6x6x5/16
COL., TYP.
MITERED
G
SS0-4
SS0-4
SIM. SS0-5
TYP.
TYP.
SS0-5
SS0-5
SIM.
TYP.
SS0-5
2 TYP.
DEGENKOLB ENGINEERS
235 Montgomery Street, Suite 500
San Francisco, CA 94104
415.392.6952 PHONE
415.981.3157 FAX N
Drawing Title
Approved: Project Director
Project Title
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
Dwg. ofRevisions: Date
CONSULTANTS:
3801 MIRANDA AVE. PALO ALTO, CA 94304
ARCHITECT/ENGINEERS:
Office of Facilities
Management
MAY 5, 2017
o n e e ig h th in c h o n e fo o t
B
A
C
D
E
F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
VA FORM 08-6231, OCT 1978
1 2 3 4 5 6 87 9
F
E
D
C
B
A
97 8654321
T (415) 682-7376 F (415) 682-7339
239 9TH STREET, SUITE 201
SAN FRANCISCO, CA 94103
640-12-124P www.meiarchitects.com
KEY PLAN
4/25/2017 8:29:00 AM
CANTEEN PLAZA CANOPY
FOUNDATION AND ROOF FRAMING
PLAN
RENOVATE CANTEEN PLAZA
BUILDING 101
Checker Author
SS0-3
1/8" = 1'-0"
3 CANOPY I FOUNDATION PLAN
1/8" = 1'-0"
4 CANOPY I FRAMING PLAN
1/8" = 1'-0"
CANOPIES II, III, IV, V & VI
FOUNDATION PLAN
1/8" = 1'-0"
CANOPIES II, III, IV, V & VI
FRAMING PLAN
T.O. GRADE
0' - 0"
T.O. CANOPY
10' - 6"
F G
HSS BEAM, SEE PLAN
HSS COL, SEE PLAN
SS0-5
SS0-5
SS0-5
SS0-5
T.O. FND
-0' - 6"
T.O. GRADE
0' - 0"
T.O. CANOPY
10' - 6"
5 6 7
SS0-5
SS0-5
SS0-5
HSS COL., SEE PLAN
HSS BEAM, SEE PLAN
TYP.
SS0-5
SIM.
SS0-5
SIM.
SS0-5
2 SIM.
T.O. FND
-0' - 6"
WALL, S.A.D.
WALL FND S.A.D.
DEGENKOLB ENGINEERS
235 Montgomery Street, Suite 500
San Francisco, CA 94104
415.392.6952 PHONE
415.981.3157 FAX N
Drawing Title
Approved: Project Director
Project Title
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
Dwg. ofRevisions: Date
CONSULTANTS:
3801 MIRANDA AVE. PALO ALTO, CA 94304
ARCHITECT/ENGINEERS:
Office of Facilities
Management
MAY 5, 2017
o n e e ig h th in c h o n e fo o t
B
A
C
D
E
F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
VA FORM 08-6231, OCT 1978
1 2 3 4 5 6 87 9
F
E
D
C
B
A
97 8654321
T (415) 682-7376 F (415) 682-7339
239 9TH STREET, SUITE 201
SAN FRANCISCO, CA 94103
640-12-124P www.meiarchitects.com
KEY PLAN
4/25/2017 8:29:00 AM
ELEVATIONS RENOVATE CANTEEN PLAZA
BUILDING 101
Checker Author
SS0-4
1/2" = 1'-0"
1 CANOPY I OR VII FRAMING PLAN
1/2" = 1'-0"
2 CANOPY CANTILEVER W/ BACKSPAN
HSS BEAM,
SEE PLAN
HSS BEAM,
SEE PLAN
HSS COL., BELOW
5/16" CAP PL
HSS COL,
SEE PLAN
HSS BEAM, BELOW
HSS BEAM,
SEE PLAN
CAP PL
HSS BEAM,
SEE PLAN
HSS COL., SEE PLAN
5/16" CAP PL
HSS BEAM,
BEYOND
SECTION A-A
SECTION B-B
A
BB
A
/1
5/16
ALL
AVAILABLE
SIZES
CJP
3/16
G
G
G
G
G
G
CJP
G3/16 G
G
G
G
G
3/4"Ø ASTM F1554 GR. 36
ANCHOR ROD W/ 1 15/16"
BASE PL HOLE
3/16
TYP.
1 1/2"
T Y
P
/2
1' - 0"
HSS COLUMN,
SEE PLAN
PL WASHER
W/ STD. HOLE, TYP.
1/2" PL
'H ' S
E E
S C
H E
D U
L E
'B' SEE SCHEDULE
T Y
P
C L R
TYP.
3" CLR.
HSS COL., SEE PLAN
2" MAX., NON-SHRINK
GROUT
DOUBLE NUT &
PL WASHER
TRANSVERS REINF.,
SEE SCHEDULE
LONGIT. REINF.,
SEE SCHEDULE
LONGIT. TRANSVERSE
BOTTOM REINFORCING
3 - #5
3 - #5
3 - #5
3 - #5
'H'
DEPTH
MARK 'B'
LENGTH
'D'
WIDTH
2'-0"
3'-0"
1'-6"
1'-6"
F1
F2
2'-0"
3'-0"
GRADE
A COL. @ PAVEMENT
'H ' S
E E
S C
H E
D U
L E
S.A.D. FOR WALL
REINF.
GRADE
B COL. @ WALL
NOTE:
SEE A FOR INFO.
NOT SHOWN
S.A.D. FOR FINISHED
WALL DIMS.
HSS COL.,
SEE PLAN
HSS BEAM,
SEE PLAN
3/16
3/16 E.S.
G
G
3/16
3/16
G
G
3/16
E.S.
G
G
G
G
DEGENKOLB ENGINEERS
235 Montgomery Street, Suite 500
San Francisco, CA 94104
415.392.6952 PHONE
415.981.3157 FAX N
Drawing Title
Approved: Project Director
Project Title
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
Dwg. ofRevisions: Date
CONSULTANTS:
3801 MIRANDA AVE. PALO ALTO, CA 94304
ARCHITECT/ENGINEERS:
Office of Facilities
Management
MAY 5, 2017
o n e e ig h th in c h o n e fo o t
B
A
C
D
E
F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
VA FORM 08-6231, OCT 1978
1 2 3 4 5 6 87 9
F
E
D
C
B
A
97 8654321
T (415) 682-7376 F (415) 682-7339
239 9TH STREET, SUITE 201
SAN FRANCISCO, CA 94103
640-12-124P www.meiarchitects.com
KEY PLAN
4/25/2017 8:29:01 AM
STEEL DETAILS RENOVATE CANTEEN PLAZA
BUILDING 101
RMG KLM
SS0-5
1 1/2" = 1'-0"
2 CANOPY CANTILEVER CONNECTION
1 1/2" = 1'-0"
4 BASE PLATE DETAIL
1" = 1'-0"
6 FOOTING
1 1/2" = 1'-0"
3 BEAM TO COL. CONNECTION
| Architectural |
| AS2.03 - SITE PLAN - AREA C |
| AS4.01 - ENLARGED FLOOR & ROOF PLANS - Copy |
| AS8.01- ELEVATIONS & SCREEN TYPES |
| AS8.02 - STONE WALL SCHEDULE & FOOTING DETAILS |
| AS9.01 - DETAILS |
| Signage |
| AG4.01- SIGN TYPE DETAILS - Copy |