The submittal covers T-Fabco Corporation Model AF-1000E ceiling suspended tables with 60-inch diameter round tops designed to provide seating for up to eight persons with motorized retraction capability. The tables feature electrically powered a/c gear motors with spring assistance counterbalance, controlled by SPDT momentary contact toggle switches mounted at convenient locations, with optional key switch lockouts recommended for staff-controlled operation areas. Electrical requirements are 5 amp, 120 vac, single phase, 60 Hz, with weight support capacity of 195 lbs and a two-year parts and labor warranty. The specification section is 12 56 70.11. Tables can be mounted between standard 24-inch hung ceiling tracks or supplied with optional structural support frames for deck, rafter, or bar joist installation. Accessories include recessed mounting frames for drywall ceilings (RMF3024-4) and frames for light fixture integration (RMF9624-F). The submittal was transmitted by Kiewit-Turner Joint Venture on 7/31/2014 and approved by the VA on 9/8/2014. Installation and maintenance instructions detail uncrating procedures, pre-assembly dimensional information, hanging assembly procedures, table top installation, operating adjustments including limit switch and clutch settings, and periodic maintenance requirements including oil application to hinges every six months and stainless steel cleaning as needed.

View the file

Other files

Show all 17

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

RETURN OF SUBMITTAL

I VA File No: 12 56 70.11 - 001

Title Or Description Date: Spec. Section:

113N - Ceilina Mounted Tables I F / 12 56 70.11 Contractors Name and Address Station Lècation:

Chris Bantner 13611 East Colfax Ave.

Aurora, CO 80045

Kiewit-Turner. a Joint Venture Contract No: Project No:

13611 East Colfax Avenue VA1 01 CFM-C-01 00 554-501 Aurora, CO 80045 Transmittal Date: VA File No:

7/31/2014 12 5670.11 -001

Submittal Scope Ceiling Mounted Table data

Submittal Items Acted Upon

Submittal Item Status

001 - IBN - Ceiling Mounted Tables APP- Approved

Supplier or Manufacturer

Submittal Type

T-Fabco

Shop Drawings

Notes/Comments

Signature of Ap)horizing Official

2z Date

Received 09/08/2014

KIEWIT-TURNER

a Joint Venture

These Shop drawings/submittals have been reviewed in accordance with the provisions of the Contract Documents. Kiewit-Turners review shall not serve to relieve Subcontractors or Suppliers of contractual responsibilities for any error or deviation from contract and subcontract requirements.

0 REVIEWED - NO COMMENTS MADE

0 REVIEWED WITH COMMENTS

0 RESUBMITTAL REQUIRED

DATE 7 / 31/ 14 SIGNED Jason Wells

SUBMITTAL#: 12 56 70.11-01

H+L SOM CRA SAM

ARCHITECTS ENCINEERS

1755 Blake Street. Suite 400. Denver CO 80202

PH: 303-295-1792, FAX: 303-292-6437

VA [CHCS REPLACEMENT MEDICAL CENTER PROJECT

13611 East Colfax Avenue, Aurora, CO 80045

Project: 554.501/Contract Number: VA101CFM-C-0100

Received Date: 08/01/2014

A/ESubmittat Number: 125670.11-01

WE Comments and/or Corrections are Clouded

Reviewed By SOM/SO

Date- 8/14/2014

VA ACTION

Aroved

0 Approved, As Noted

0 Disapproved. As Noted 0 No Action

U No Devin Noted; None Approved

Fax: 303.930.9001

303.930.9000Tel:

Kiewit - Turner a Joint Venture

Suite A-300 7200 S. Alton Way

Englewood, CO 80112

Job: 15387 - Replacement Medical Center Facility

Product Data

Sample

Other

Shop Drawing

Resubmittal

First Submittal X

VA Proj #:

To: H+L Architecture 1755 Blake Street

Suite 400

Denver, CO 80202

DESCRIPTIONSpecificationSUBMITTAL

ItemQuantity Section Sub./SupplierNo. Mfgr.

ACTION

DCBA E

Kiewit Submittal No. 22 13 00-01

Architect's Submittal No. 00008

Review Cycle: 001

Attn: Chuck Adkisson

1 SWPPP - CBS & RFP #3 OnlyKiewit - Turner a

Joint Venture

01 573

ACTION TAKEN

CONTRACTOR'S SIGNATURE:

CONTRACTOR'S NOTES:

DATE: 7/12/2011

Reviewed Only for Revisions to

Reviewed: Incorporate Changes

Reviewed=

A

B

C

Previous Submittal

Revise and Resubmit=D

Rejected =E

ARCHITECT/ENGINEER RESPONSE:

REMARKS:

BY: DATE:

Expedition f_sb_pks_01a

VA101CFM-C-0100

Cc: Tim Pogany, U.S. Dept. of Veterans Affairs

Received By ___________________

Date _______________

12 56 70.11

X

IBN Ceiling Mounted Tables

X

Haldeman Homme

12 56 70.1101

07/31/2014

08/14/2014

Kiewit-Turner Submittal No.

VA 1

JVT 2

REQUESTED RETURN DATE:

Kevin Lindsey, U.S. Dept. of Veterans Affairs

By VACO BoltonT at 9:02 am, Aug 20, 2014

These shop drawings/submittals have been reviewed in accordance with the provisions of the Contract Documents. Kiewit-Turner's review shall not serve to relieve Subcontractors or Suppliers of contractual responsibilities for any error or deviation from contract and subcontract requirements.

KIEWIT-TURNER

a Joint Venture

REVIEWED - NO COMMENTS MADE

REVIEWED WITH COMMENTS

RESUBMITTAL REQUIRED

DATE SIGNED

SUBMITTAL #:

Jason Wells

X

12 56 70.1101

7/31/14

125670.11-01

08/01/2014

SOM/SC

8/14/2014

125670.11 Suspended Table Page 1 of 1

Kiewit-Turner a Joint Venture 7200 S. Alton Way, Suite A-300, Englewood, CO 80112

Phone: 303-930-9000 FAX: 303-930-9001

Project Name:

Subcontractor Name: Submittal Date:

Contact Name: E-mail: Return By Date:

Contact Phone(s): Review Days:

Number: Name:

1.3.B

JSN # U4183 Suspended Table Assembly T-fabco Corporation Y Y N Y X

Submittal is in Compliance Submittal is in Compliance with Variances from Specifications

Signature Jeff Anderson

MANUFACTURER'S LITERATURE PRODUCT DATA and SHOP

DRAWING

Reviewed By Date

M ee ts A ll Sp ec

R eq ui re m en ts

Ex ce pt io ns o r Va ria nc es fr om S pe c?

A pp ro ve r I nf or m at io n N ee de d?

In T hi s

Pa ck ag e

Submittal Type

Submittal Item Description Manufacturer / Model

303-867-0484

Specification Section: 12 56 70.11 Suspended Table

Sp ec

. S ub m itt al

Pa ra gr ap h

Sp ec

. P ro du ct

Pa ra gr ap h

(E Q

U

IP

M

EN

T

IT

EM

Sp ec ifi ed o r L is te d M an uf ac tu re r?

SUBMITTAL INDEX & COVER SHEET Department of Veteran's Affairs Replacement Medical Center

Haldeman-Homme Inc. 05/16/14 Jeff Anderson janderson@haldemanhomme.com mailto:janderson@haldemanhomme.com

T-fabco

Tables Retracted for Easy Storage

T-fabco Corp.

P.O.Box 1436

11550 U.S. Hwy 41 Gibsonton, FL

33534

Watts 877-738-2080 Fax 813-671-1865

Installation

Table units are designed to fit between the standard 24” hung ceiling tracks and they can be supplied with structural support frames for deck, rafter, or bar joist installation support.

A trim flange and mounting kit is available for drywall ceiling installations

A “troffer” frame is available for recessing the table unit into the ceiling. This accessory will provide an additional 8” of floor clearance and it also allows for the installation of 24” x 24” lay-in light fixtures if desired.

Specifications

Electrical Supply: 5 amp, 120 vac, Single Phase, 60 hz

Weight Support requirements 195 lbs.

Two-year parts and labor warranty.

Controls

Individual “UP/DOWN” SPDT momentary contact (Pass & Seymour # 1205 or equiv. By others).

(Optional) Electric Key switch - This lock-out control is suggested in areas where staff control of the tables is necessary.

Models & Accessories

AF 1000E- Ceiling Suspended table assembly with 60” diameter table top, stainless steel support arms and high-pressure laminate table top.

RMF3024-4- Recessed Mounting Frame with Trim Flange for drywall (GWB) ceiling.

RMF9624-F - Recessed mounting frame for lights.

SMF1000 - Structural Mounting Frame for deck or welding to bar joist.

12 56 70 . 11 Suspended Table

2.2 Suspended Tables JSN # U4183

Provide for Apartment 05-03-G2-01

Steel supports for Suspended Ceilings will be provided under a separate submittal.

Plastic Laminate color to match PL06.

Edge Vinyl Trim color to match PL06.

Housing color to match P10.

Surface mounted per the specifications.

JSN # U4183

Ceiling Heights Vary by Room. See contract drawings

ARCHITECT: ENGINEERS:

GENERAL CONTRACTOR - PROJECT TEAM

HALDEMAN-HOMME - PROJECT TEAM

MANUFACTURER

Skidmore, Owings & Merrill LLP 224 South Michigan Ave, STE 1000 Chicago, IL 60604 Contact:

Kiewit-Turner a Joint Venture

13611 E. Colfax Ave, Second Floor Aurora, CO 80045

DEPARTMENT OF VETERAN'S AFFAIRS

REPLACEMENT MEDICAL CENTER

AURORA, CO

HH32959

HH PROJECT NUMBER:

DRAWN BY:

RLW

SHEET TITLE:

PROJECT COVER

ORIGINAL DRAWING IS 11 x 17 1

PROJECT:

SUBMITTAL/REVISIONS

DATE REASON BYNO.

RLWQUALITY CONTROL03-20-14

LDP05-12-14 DATE OF SUBMITTAL

DATE REASON BY

DESIGN /DEVELOPMENT

NO.

PROJECT STATUS:

WWW.HALDEMANHOMME.COM

ROCKY MOUNTAIN LAB DIVISION

HALDEMAN-HOMME, INC.

CORPORATE OFFICE

PHONE: (612) 331-4880

MINNEAPOLIS, MN 55413

430 INDUSTRIAL BOULEVARD

TOLL FREE: (800) 795-0696

PHONE: (303) 237-1333

ENGLEWOOD, COLORADO 80112

8676 CONCORD CENTER DRIVE

SOUTHWEST LAB DIVISION

PHONE: (832) 626-1061

HOUSTON, TEXAS 77032

FAX: (612) 378-2236

COMPANY: METAL CASEWORK & FUME HOODS

COMPANY: STAINLESS STEEL FABRICATIONS

DEPARTMENT OF VETERAN'S AFFAIRS

REPLACEMENT MEDICAL CENTER

AURORA, CO

PROJECT OWNER:

OFFICE OF CONSTRUCTION & FACILITIES MANAGEMENT

DEPARTMENT OF VETERANS AFFAIRS

Contact:

PROJECT NUMBER: 527584

PROJECT NUMBER: 2199-12

PROJECT NUMBER: C677

HALDEMAN-HOMME, INC CORPORATE OFFICE

430 INDUSTRIAL BOULEVARD NE

MINNEAPOLIS, MINNESOTA 55413

PHONE: (612) 331-4880

EMPLOYEE OWNED

AN EMPLOYEE OWNED COMPANY ENGAGED IN THE DISTRIBUTION OF

EDUCATIONAL, INDUSTRIAL & INSTITUTIONAL EQUIPMENT.

ESOP

THESE DRAWINGS REMAIN THE PROPERTY OF HALDEMAN-HOMME INC. & ARE LOANED SUBJECT TO RETURN UPON DEMAND & UPON THE EXPRESS CONDITION THAT IT WILL NOT BE USED DIRECTLY OR INDIRECTLY IN ANY WAY DETRIMENTAL ARE FURNISHED FOR THE SOLE INTENT OF APPROVAL & INSTALLING PRODUCT SUPPLIED BY HALDEMAN-HOMME, INC.

HALDEMAN-HOMME, INC. DOES NOT GUARANTEE THEIR ACCURACY TO, NOR WARRANT THEIR FITNESS FOR USE BY OTHERS.

PROJECT MANAGER: OLIN VALENTINE

PHONE: (303) 867-0494

OVALENTINE@HALDEMANHOMME.COM

HALDEMAN-HOMME, INC.

ROCKY MOUNTAIN LAB DIVISION

8676 CONCORD CENTER DRIVE

ENGLEWOOD, COLORADO 80112

PHONE: (303) 237-1333

Cator, Ruma & Associates 896 Tabor Street, Lakewood, CO 80401 Contact:

CORP. OPERATIONS MGR: JEFF ANDERSON

PHONE: (303) 867-0484

JANDERSON@HALDEMANHOMME.COM

OPERATIONS MANAGER: BILL TOLLEY

PHONE: (303) 867-0482

BTOLLEY@HALDEMANHOMME.COM

CAD ENGINEER: LES PHELPS

PHONE: (612) 462-7182

LPHELPS@HALDEMANHOMME.COM

INSTALLATION MANAGER: RANDY RUTLEDGE

PHONE: (303) 867-0480

RRUTLEDGE@HALDEMANHOMME.COM

JOINT VENTURE TEAM

EPOXYN PRODUCTS - LABORATORY WORKSURFACES & SINKS

500 EAST 16TH STREET, MOUNTAIN HOME, ARKANSAS 72653

HAMILTON SCIENTIFIC - LABORATORY FURNITURE

1716 LAWRENCE DRIVE, STE 1, DE PERE, WISCONSIN 54115

KLOPPENBERG & COMPANY - LABORATORY FIXTURES

2627 W OXFORD AVENUE, ENGLEWOOD, COLORADO 80110

SHEET LEGEND

H&l Architecture 1755 Blake Street, STE 400 Denver, CO 80202 Contact:

S.A. Micro, Inc.

4582 Ulster Street Pkwy, STE 300 Denver, CO 80237 Contact:

SUBMITTED FOR APPROVAL

SUBMITTED FOR DIMENSIONS

FABRICATION / INSTALL SET

CONSTRUCTION DRAWINGS

DESIGN / DEVELOPMENT

RE-SUBMITTED FOR APPROVAL

SHEET SHEET DESCRIPTION

COVER PROJECT COVER

INDEX DRAWING INDEX

DN DRAWING NOTES

DS DRAWING SCHEDULES

CO CASEWORK OPTIONS

CL CASEWORK LIBRARY

CP CASEWORK PLANS

CE CASEWORK ELEVATIONS

CS CASEWORK SECTIONS

CD CASEWORK DETAILS

APPROVAL STAMP

COMPANY: EPOXY RESIN COUNTER TOPS

03.CP0.01

BUILDING NUMBER

SHEET TYPE - SEE LEGEND

BUILDING LEVEL

SEQUENTIAL NUMBER

SHEET NUMBERING

PROJECT ENGINEER:

SARAH HARTSFIELD, LEED AP BD+C

MOBILE: (202) 369-4098

EMAIL: SARAH.HARTSFIELD@KIEWITTURNER.COM

EXAMPLE SHEET NUMBER

LABORATORY CASEWORK & ACCESSORY SUBMITTAL FOR:

05-IBN INPATIENT BUILDING

(NORTH)

PROJECT MANAGER - LAB CASEWORK & EQUIPMENT

MARK JOHNSON

MOBILE:

EMAIL: MARK.JOHNSON@KIEWITTURNER.COM

BUILDING: 05-IBN

PROJECT MANAGER

LAURA PRENDERGAST

MOBILE:

EMAIL:

5/13/2014 8:48:55 AM

A

L

I G

N

A

L

I G

N

A L I G

N

RB

RA

EJ

UP

DN

05-01-ST1

STAIR

05-01-RAR1-08

PAT STOR

05-01-RAR1-02

WAIT

05-01-RAR1-03

CONF

05-01-RBR1-02

PHARMACY

05.CE1.01

HH#540

TABLE

CEILING MOUNTED

R2

05-01-RAR1-07

CORRIDOR

05-01-RAR1-06

DINING/SERVING

05-01-RAR1-03

CONF

05-01-RAR1-04

STORAGE

05-01-RAR1-05

MULTIPURPOSE

05-01-RAR1-07

CORRIDOR

05-01-RAR1-10

SERVERY

05-01-ST1

STAIR

05-01-RAR1-08

PAT STOR

05-01-RAR1-02

WAIT

05-01-RAR1-03

CONF

05-01-RAR1-04

STORAGE

HH#540

TABLE

CEILING MOUNTED

HH#540

TABLE

CEILING MOUNTED

HH#540

TABLE

CEILING MOUNTED

HH#540

TABLE

CEILING MOUNTED

HH#540

TABLE

CEILING MOUNTED

6'-21 2" Verify

14'-0" Verify

'-0

Ve ri fy

'-0

Ve ri fy

7' -0

Ve ri fy

7' -0

Ve ri fy

7' -0

Ve ri fy

7'-31 8" Verify

ARCHITECT NOTE:

ADVISE CONTROL SWITCH LOCATION FOR

SUSPENDED (CEILING MOUNTED) TABLE LIFTS.

REVIEW LIGHTING LAYOUT AS SOME LIGHTS MAY

CONFLICT WITH TABLES AS CURRENTLY SHOWN ON

THE ELECTRICAL DRAWINGS.

DATE

DRAWN

SCALE

NOMINAL

PROJECT

PROJECT

MANAGER

ARCHITECT/ENGINEER

HALDEMAN-HOMME, INC

“Exceeding Customer Expectations Since 1924 ”

05.CP1.0305-IBN LEVEL 01 - AREA C FLOOR PLAN

HH32959

LDP

05/12/14

1/16"=1'-0"

ORV

H+L-SOM | CRA-SAM

-11 12 08 09 13

03040506

Key Plan

BUILDING IDENTIFICATION:

05 - IBN INPATIENT BUILDING (NORTH)

N

PARTIAL FLOOR PLAN FOR:

05-IBN, LEVEL 01 - AREA C

Reference Architectural Plan Sheet: 05.AI.401-C

A B

C

5/13/2014 8:49:35 AM

JSN # U4183

Architect - Please see VA RFI#4436 for questions and clarifications with the coordination of the suspended tables.

E

RE

R2

R1

05-03-D3-H1

CHUTE

05-03-D2-06

FOOD CART

ALCOVE

05-03-D1-04

PATIENT RM

05-03-RDR1-02

PAT TLT

05-03-RDR1-04

PATIENT RM

05-03-D3-03B

OFFICE

05-03-D3-05

OFFICE

05-03-D2-08

STAFF

LOUNGE/LOCKERS

05-03-C2-03

CORRIDOR

J

H

G

F

E

RG

RH

RJ

RF

R2

R1

K

05-03-F3-E2

ELEC

05-03-F2-T2

DATA / TELECOMM

05-03-ST2

STAIR

05-03-J1-01

TERRACE

05-03-RER1-04

PATIENT RM

05-03-RHR1-01

POS PRES

PATIENT RM

05-03-RER1-01

PATIENT RM, NEG

PRES

05-03-H1-04

ORTHO CAST

STOR

05-03-E2-03

MED

05-03-F1-01

PATIENT RM, NEG

PRES

05-03-H1-01

PATIENT RM

05-03-E1-01

PATIENT RM, NEG

PRES

05-03-E1-02

PAT TLT

05-03-E1-03

PAT TLT

05-03-E1-04

PATIENT RM

05-03-F1-02

PAT TLT

05-03-F1-03

PAT TLT

05-03-F1-04

PATIENT RM

05-03-G1-01

PATIENT RM

05-03-G1-02

PAT TLT

05-03-G1-03

PAT TLT

05-03-G1-04

PATIENT RM

05-03-H1-02

PAT TLT

05-03-RHR1-02

POS PRES

ANTEROOM

05-03-RHR1-03

PAT TLT

05-03-H2-01

NURSE

SUBSTATION

05-03-F2-02

EQUIP STOR

05-03-E3-06

OFFICE

05-03-F3-02

HAC

05-03-RGR1-04

PATIENT RM

05-03-RGR1-02

PAT TLT

05-03-RGR1-03

PAT TLT

05-03-RGR1-01

PATIENT RM

05-03-RFR1-02

PAT TLT

05-03-RFR1-03

PAT TLT

05-03-RFR1-01

PATIENT RM

05-03-RER1-02

PAT TLT

05-03-RER1-03

PAT TLT

05-03-G2-02

LIVING/MULTIPURPOSE

05-03-G2-01

APARTMENT

05-03-E3-04

CLEAN LINEN

05-03-E2-05

CLEAN UTIL

05-03-E2-06

SOILED UTIL

05-03-E2-08

NOURISH

05-03-E2-02

NURSE STATION

05-03-E2-09

MED GAS STOR

05-03-F2-03

LAUNDRY

05-03-G2-03

DINING

05-03-F3-03

X-RAY MACH

ALCOVE

05-03-RHR1-04

OFFICE

05-03-E3-06B

OFFICE

05-03-E3-05

NURSE STATION

05-03-E2-01

CONSULT

05-03-RFR1-04

PATIENT RM

05-03-F3-01

CORRIDOR

05-03-H3-01

TLT

05-03-H1-03

STAFF TLT

05-03-E2-06B

CRASH CART

ALCOVE

05-03-E3-05A

NURSE

STATION_STOR

05-03-E2-02A

NURSE

STATION_STOR

05-03-G2-01C

APARTMENT_STOR

05.CE3.01

05.CE3.02

HH#559

RACK, STORAGE

CYLINDER GAS

HH#541

TABLE

CEILING MOUNTED

HH#542

TABLE

CEILING MOUNTED

8'-0" Verify

6'-0" Verify

6'-8 9 16"

Verify

4' -0

Ve ri fy

9'-0" Verify

HH#542

TABLE

CEILING MOUNTED

HH#097

HEADWALL

HH#098

HEADWALL

HH#099

HEADWALL

HH#100

HEADWALL

HH#101

HEADWALL

HH#102

HEADWALL

HH#103

HEADWALL

HH#104

HEADWALL

HH#112

HEADWALL

HH#113

HEADWALL

HH#114

HEADWALL

HH#115

HEADWALL

HH#116

HEADWALL

HH#117

HEADWALL

HH#118

HEADWALL

HH#119

HEADWALL

HH#559

RACK, STORAGE

CYLINDER GAS

(X2)

11 12 08 09 13

03040506

Key Plan

BUILDING IDENTIFICATION:

05 - IBN INPATIENT BUILDING (NORTH)

DATE

DRAWN

SCALE

NOMINAL

PROJECT

PROJECT

MANAGER

ARCHITECT/ENGINEER

HALDEMAN-HOMME, INC

“Exceeding Customer Expectations Since 1924 ”

05.CP3.0205-IBN LEVEL 03 - AREA B FLOOR PLAN

HH32959

LDP

05/12/14

1/16"=1'-0"

ORV

H+L-SOM | CRA-SAM

ARCHITECTS | ENGINEERS

N

PARTIAL FLOOR PLAN FOR:

05-IBN, LEVEL 03 - AREA B

Reference Architectural Plan Sheet: 05.AI.403-B

A B

5/13/2014 8:50:19 AM

JSN # U4183

See VA RFI 4436 for location of suspended tables

Fax: 303.930.9001

303.930.9000Tel:

Kiewit - Turner a Joint Venture

Suite A-300 7200 S. Alton Way

Englewood, CO 80112

Job: 15387 - Replacement Medical Center Facility

Product Data

Sample

Other

Shop Drawing

Resubmittal

First Submittal X

VA Proj #:

To: H+L Architecture 1755 Blake Street

Suite 400

Denver, CO 80202

DESCRIPTIONSpecificationSUBMITTAL

ItemQuantity Section Sub./SupplierNo. Mfgr.

ACTION

DCBA E

Kiewit Submittal No. 22 13 00-01

Architect's Submittal No. 00008

Review Cycle: 001

Attn: Chuck Adkisson

1 SWPPP - CBS & RFP #3 OnlyKiewit - Turner a

Joint Venture

01 573

ACTION TAKEN

CONTRACTOR'S SIGNATURE:

CONTRACTOR'S NOTES:

DATE: 7/12/2011

Reviewed Only for Revisions to

Reviewed: Incorporate Changes

Reviewed=

A

B

C

Previous Submittal

Revise and Resubmit=D

Rejected =E

ARCHITECT/ENGINEER RESPONSE:

REMARKS:

BY: DATE:

Expedition f_sb_pks_01a

VA101CFM-C-0100

Cc: Tim Pogany, U.S. Dept. of Veterans Affairs

Received By ___________________

Date _______________

12 56 70.11

X

GENO&M_Suspended Tables

X

HaldemanHomme, Inc.

12 56 70.11002

10/07/2016

10/21/2016

Kiewit-Turner Submittal No.

COE 1

REQUESTED RETURN DATE:

Kevin Lindsey, U.S. Dept. of Veterans Affairs

VA101F-15-C-0005

13611 E. Colfax Avenue 2nd Floor Aurora, CO 80045

DEPARTMENT OF THE ARMY

Omaha District Corps of Engineers 13611 East Colfax Avenue 2nd Floor Aurora, CO 80045

W9128F-16-C-0003

Peter Sturdivant

These shop drawings/submittals have been reviewed in accordance with the provisions of the Contract Documents. Kiewit-Turner's review shall not serve to relieve Subcontractors or Suppliers of contractual responsibilities for any error or deviation from contract and subcontract requirements.

KIEWIT-TURNER

a Joint Venture

REVIEWED - NO COMMENTS MADE

REVIEWED WITH COMMENTS

RESUBMITTAL REQUIRED

DATE SIGNED

SUBMITTAL #:

12 56 70.11-002

09/29/16 Mark S. Johnson

Kiewit-Turner a Joint Venture

7200 S. Alton Way, Suite A-300, Englewood, CO 80112

Phone: 303-930-9000 FAX: 303-930-9001

Project Name:

Subcontractor Name: Submittal Date:

Contact Name: E-mail: Return By Date:

Contact Phone(s): Review Days:

Number: Name:

O&M Manuals

Reviewed By Date 9/29/2016

Submittal is in Compliance

Submittal is in Compliance with Variances from Specifications

Signature

SUBMITTAL INDEX & COVER SHEET

Department of Veteran's Affairs

Replacement Medical Center

Haldeman Homme 09/29/16

Bill Tolley btolley@haldemanhomme.com

303-867-0482

Specification Section: 12 56 70.11 Suspended Tables

S p e c

S u b m it ta l

P a ra g ra p h

S p e c

P ro d u c t

P a ra g ra p h

S p e c if ie d o r

L is te d

M a n u fa c tu re r?

M e e ts

A ll

S p e c

R e q u ir e m e n ts

E x c e p ti o n s o r

V a ri a n c e s f ro m

S p e c

A p p ro v e r

In fo rm a ti o n

N e e d e d

I n

T h is P a c k a g e

Submittal Type

Submittal Item Description Manufacturer

T Fabco

Mark Johnson

SubmittalIndexForm_041009 Page 1 of 1

Kiewit - Turner ^^^^^_^^^^^^aJointVenture

Division 12 Furnishings Section 12 56 70.11 Suspended Tables

Suspended Tables No Operations & Maintenance Manuals

Specified Haldeman Homme, Inc.

T-fabco Corporation presents

Suspended table submittals

Project: V A Denver Replacement Medical Facility

Location: Aurora

Architect:

Contractor: Haldeman - Homme, Inc.

Contract Number: 32959-5719

Date:

Revision Date(s) :

Prepared By : Jerry Harburg

Architect Approval :

Approval Date:

Page of

P. O. Box 1436 I Gibsonton, FL 33534 Phone (877) 738-2080 I Fax (813) 671-1865 www.uptable.com

TYPICAL DECK MOUNT FRAME

liny

WELD TO G.C. SUPPLIED

IMLANTS .ANGLES OR

ATTACH WITH RAWL

PLUGS

WELDED 3”X1/4” STEEL

MOUNTING FRAME

24"

18"

I m r

FIELD VERIFY

J

AF3024

Mounting Frame and mounting bolts by T-fabco

32”

26”

E iCn

4" MINIMUM

‘ f

LJ

L 2” s s

END VIEW

Hung Ceiling Track ------- /

Table motor housing

SIDE VIEW

CEILING SUSPENDED TABLE AF 1000E

DISTANCE FROM

HUNG CEILING TO

FLOOR=

12 56 70.11-01 - IBN - Ceiling Mounted Tables
12 56 70.11-02 - GEN_OandM_Haldeman_Homme_Suspended_Tables
12 56 70.11 Suspended Tables

photos

File details come from the government source that posted it. Updated .