This document is a submittal package for ceiling-mounted suspended tables for the Department of Veterans Affairs (VA) Replacement Medical Center project in Aurora, Colorado.
The submittal covers T-Fabco Corporation Model AF-1000E ceiling suspended tables with 60-inch diameter round tops designed to provide seating for up to eight persons with motorized retraction capability. The tables feature electrically powered a/c gear motors with spring assistance counterbalance, controlled by SPDT momentary contact toggle switches mounted at convenient locations, with optional key switch lockouts recommended for staff-controlled operation areas. Electrical requirements are 5 amp, 120 vac, single phase, 60 Hz, with weight support capacity of 195 lbs and a two-year parts and labor warranty. The specification section is 12 56 70.11. Tables can be mounted between standard 24-inch hung ceiling tracks or supplied with optional structural support frames for deck, rafter, or bar joist installation. Accessories include recessed mounting frames for drywall ceilings (RMF3024-4) and frames for light fixture integration (RMF9624-F). The submittal was transmitted by Kiewit-Turner Joint Venture on 7/31/2014 and approved by the VA on 9/8/2014. Installation and maintenance instructions detail uncrating procedures, pre-assembly dimensional information, hanging assembly procedures, table top installation, operating adjustments including limit switch and clutch settings, and periodic maintenance requirements including oil application to hinges every six months and stainless steel cleaning as needed.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| RFI Q and A 56 to 64 SCI Apt 02-04-2026 VA.docx | DOCX document | |
| 01 35 26 safety 2026-02-04.pdf | ||
| 36C25926R0032 0002.docx | DOCX document | |
| Pre bid Site Visit Attendance 15-01-2026.pdf | ||
| S04 - Site Visit Meeting Doc.docx | DOCX document | |
| 36C25926R0032 0001.docx | DOCX document | |
| Answers to RFI Questions 41 to 55 SCI Apt 2026-01-23 VA.pdf | ||
| Drawings 554-23-101 Construct New SCI set 1 of 2.pdf | ||
| S02-Specifications 554-23-101 Construct New SCI.pdf | ||
| 36C25926R0032_1.docx | DOCX document | |
| 554-23-101 - Construct New SCI -ASI 01.pdf | ||
| RFI Q and A 1 to 40.pdf | ||
| Past Performance Questionnaire_Blank.docx | DOCX document | |
| Prime and Sub Contractor Construction Breakdown.xlsx | XLSX spreadsheet | |
| 852.219- 75 LOS Certification.docx | DOCX document | |
| Drawings 554-23-101 New SCI Apartment set 2 of 2.pdf | ||
| Self-Performed and Subcontracted Worksheet.docx | DOCX document |
Show all 17
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
RETURN OF SUBMITTAL
I VA File No: 12 56 70.11 - 001
Title Or Description Date: Spec. Section:
113N - Ceilina Mounted Tables I F / 12 56 70.11 Contractors Name and Address Station Lècation:
Chris Bantner 13611 East Colfax Ave.
Aurora, CO 80045
Kiewit-Turner. a Joint Venture Contract No: Project No:
13611 East Colfax Avenue VA1 01 CFM-C-01 00 554-501 Aurora, CO 80045 Transmittal Date: VA File No:
7/31/2014 12 5670.11 -001
Submittal Scope Ceiling Mounted Table data
Submittal Items Acted Upon
Submittal Item Status
001 - IBN - Ceiling Mounted Tables APP- Approved
Supplier or Manufacturer
Submittal Type
T-Fabco
Shop Drawings
Notes/Comments
Signature of Ap)horizing Official
2z Date
Received 09/08/2014
KIEWIT-TURNER
a Joint Venture
These Shop drawings/submittals have been reviewed in accordance with the provisions of the Contract Documents. Kiewit-Turners review shall not serve to relieve Subcontractors or Suppliers of contractual responsibilities for any error or deviation from contract and subcontract requirements.
0 REVIEWED - NO COMMENTS MADE
0 REVIEWED WITH COMMENTS
0 RESUBMITTAL REQUIRED
DATE 7 / 31/ 14 SIGNED Jason Wells
SUBMITTAL#: 12 56 70.11-01
H+L SOM CRA SAM
ARCHITECTS ENCINEERS
1755 Blake Street. Suite 400. Denver CO 80202
PH: 303-295-1792, FAX: 303-292-6437
VA [CHCS REPLACEMENT MEDICAL CENTER PROJECT
13611 East Colfax Avenue, Aurora, CO 80045
Project: 554.501/Contract Number: VA101CFM-C-0100
Received Date: 08/01/2014
A/ESubmittat Number: 125670.11-01
WE Comments and/or Corrections are Clouded
Reviewed By SOM/SO
Date- 8/14/2014
VA ACTION
Aroved
0 Approved, As Noted
0 Disapproved. As Noted 0 No Action
U No Devin Noted; None Approved
Fax: 303.930.9001
303.930.9000Tel:
Kiewit - Turner a Joint Venture
Suite A-300 7200 S. Alton Way
Englewood, CO 80112
Job: 15387 - Replacement Medical Center Facility
Product Data
Sample
Other
Shop Drawing
Resubmittal
First Submittal X
VA Proj #:
To: H+L Architecture 1755 Blake Street
Suite 400
Denver, CO 80202
DESCRIPTIONSpecificationSUBMITTAL
ItemQuantity Section Sub./SupplierNo. Mfgr.
ACTION
DCBA E
Kiewit Submittal No. 22 13 00-01
Architect's Submittal No. 00008
Review Cycle: 001
Attn: Chuck Adkisson
1 SWPPP - CBS & RFP #3 OnlyKiewit - Turner a
Joint Venture
01 573
ACTION TAKEN
CONTRACTOR'S SIGNATURE:
CONTRACTOR'S NOTES:
DATE: 7/12/2011
Reviewed Only for Revisions to
Reviewed: Incorporate Changes
Reviewed=
A
B
C
Previous Submittal
Revise and Resubmit=D
Rejected =E
ARCHITECT/ENGINEER RESPONSE:
REMARKS:
BY: DATE:
Expedition f_sb_pks_01a
VA101CFM-C-0100
Cc: Tim Pogany, U.S. Dept. of Veterans Affairs
Received By ___________________
Date _______________
12 56 70.11
X
IBN Ceiling Mounted Tables
X
Haldeman Homme
12 56 70.1101
07/31/2014
08/14/2014
Kiewit-Turner Submittal No.
VA 1
JVT 2
REQUESTED RETURN DATE:
Kevin Lindsey, U.S. Dept. of Veterans Affairs
By VACO BoltonT at 9:02 am, Aug 20, 2014
These shop drawings/submittals have been reviewed in accordance with the provisions of the Contract Documents. Kiewit-Turner's review shall not serve to relieve Subcontractors or Suppliers of contractual responsibilities for any error or deviation from contract and subcontract requirements.
KIEWIT-TURNER
a Joint Venture
REVIEWED - NO COMMENTS MADE
REVIEWED WITH COMMENTS
RESUBMITTAL REQUIRED
DATE SIGNED
SUBMITTAL #:
Jason Wells
X
12 56 70.1101
7/31/14
125670.11-01
08/01/2014
SOM/SC
8/14/2014
125670.11 Suspended Table Page 1 of 1
Kiewit-Turner a Joint Venture 7200 S. Alton Way, Suite A-300, Englewood, CO 80112
Phone: 303-930-9000 FAX: 303-930-9001
Project Name:
Subcontractor Name: Submittal Date:
Contact Name: E-mail: Return By Date:
Contact Phone(s): Review Days:
Number: Name:
1.3.B
JSN # U4183 Suspended Table Assembly T-fabco Corporation Y Y N Y X
Submittal is in Compliance Submittal is in Compliance with Variances from Specifications
Signature Jeff Anderson
MANUFACTURER'S LITERATURE PRODUCT DATA and SHOP
DRAWING
Reviewed By Date
M ee ts A ll Sp ec
R eq ui re m en ts
Ex ce pt io ns o r Va ria nc es fr om S pe c?
A pp ro ve r I nf or m at io n N ee de d?
In T hi s
Pa ck ag e
Submittal Type
Submittal Item Description Manufacturer / Model
303-867-0484
Specification Section: 12 56 70.11 Suspended Table
Sp ec
. S ub m itt al
Pa ra gr ap h
Sp ec
. P ro du ct
Pa ra gr ap h
(E Q
U
IP
M
EN
T
IT
EM
Sp ec ifi ed o r L is te d M an uf ac tu re r?
SUBMITTAL INDEX & COVER SHEET Department of Veteran's Affairs Replacement Medical Center
Haldeman-Homme Inc. 05/16/14 Jeff Anderson janderson@haldemanhomme.com mailto:janderson@haldemanhomme.com
T-fabco
Tables Retracted for Easy Storage
T-fabco Corp.
P.O.Box 1436
11550 U.S. Hwy 41 Gibsonton, FL
33534
Watts 877-738-2080 Fax 813-671-1865
Installation
Table units are designed to fit between the standard 24” hung ceiling tracks and they can be supplied with structural support frames for deck, rafter, or bar joist installation support.
A trim flange and mounting kit is available for drywall ceiling installations
A “troffer” frame is available for recessing the table unit into the ceiling. This accessory will provide an additional 8” of floor clearance and it also allows for the installation of 24” x 24” lay-in light fixtures if desired.
Specifications
Electrical Supply: 5 amp, 120 vac, Single Phase, 60 hz
Weight Support requirements 195 lbs.
Two-year parts and labor warranty.
Controls
Individual “UP/DOWN” SPDT momentary contact (Pass & Seymour # 1205 or equiv. By others).
(Optional) Electric Key switch - This lock-out control is suggested in areas where staff control of the tables is necessary.
Models & Accessories
AF 1000E- Ceiling Suspended table assembly with 60” diameter table top, stainless steel support arms and high-pressure laminate table top.
RMF3024-4- Recessed Mounting Frame with Trim Flange for drywall (GWB) ceiling.
RMF9624-F - Recessed mounting frame for lights.
SMF1000 - Structural Mounting Frame for deck or welding to bar joist.
12 56 70 . 11 Suspended Table
2.2 Suspended Tables JSN # U4183
Provide for Apartment 05-03-G2-01
Steel supports for Suspended Ceilings will be provided under a separate submittal.
Plastic Laminate color to match PL06.
Edge Vinyl Trim color to match PL06.
Housing color to match P10.
Surface mounted per the specifications.
JSN # U4183
Ceiling Heights Vary by Room. See contract drawings
ARCHITECT: ENGINEERS:
GENERAL CONTRACTOR - PROJECT TEAM
HALDEMAN-HOMME - PROJECT TEAM
MANUFACTURER
Skidmore, Owings & Merrill LLP 224 South Michigan Ave, STE 1000 Chicago, IL 60604 Contact:
Kiewit-Turner a Joint Venture
13611 E. Colfax Ave, Second Floor Aurora, CO 80045
DEPARTMENT OF VETERAN'S AFFAIRS
REPLACEMENT MEDICAL CENTER
AURORA, CO
HH32959
HH PROJECT NUMBER:
DRAWN BY:
RLW
SHEET TITLE:
PROJECT COVER
ORIGINAL DRAWING IS 11 x 17 1
PROJECT:
SUBMITTAL/REVISIONS
DATE REASON BYNO.
RLWQUALITY CONTROL03-20-14
LDP05-12-14 DATE OF SUBMITTAL
DATE REASON BY
DESIGN /DEVELOPMENT
NO.
PROJECT STATUS:
WWW.HALDEMANHOMME.COM
ROCKY MOUNTAIN LAB DIVISION
HALDEMAN-HOMME, INC.
CORPORATE OFFICE
PHONE: (612) 331-4880
MINNEAPOLIS, MN 55413
430 INDUSTRIAL BOULEVARD
TOLL FREE: (800) 795-0696
PHONE: (303) 237-1333
ENGLEWOOD, COLORADO 80112
8676 CONCORD CENTER DRIVE
SOUTHWEST LAB DIVISION
PHONE: (832) 626-1061
HOUSTON, TEXAS 77032
FAX: (612) 378-2236
COMPANY: METAL CASEWORK & FUME HOODS
COMPANY: STAINLESS STEEL FABRICATIONS
DEPARTMENT OF VETERAN'S AFFAIRS
REPLACEMENT MEDICAL CENTER
AURORA, CO
PROJECT OWNER:
OFFICE OF CONSTRUCTION & FACILITIES MANAGEMENT
DEPARTMENT OF VETERANS AFFAIRS
Contact:
PROJECT NUMBER: 527584
PROJECT NUMBER: 2199-12
PROJECT NUMBER: C677
HALDEMAN-HOMME, INC CORPORATE OFFICE
430 INDUSTRIAL BOULEVARD NE
MINNEAPOLIS, MINNESOTA 55413
PHONE: (612) 331-4880
EMPLOYEE OWNED
AN EMPLOYEE OWNED COMPANY ENGAGED IN THE DISTRIBUTION OF
EDUCATIONAL, INDUSTRIAL & INSTITUTIONAL EQUIPMENT.
ESOP
THESE DRAWINGS REMAIN THE PROPERTY OF HALDEMAN-HOMME INC. & ARE LOANED SUBJECT TO RETURN UPON DEMAND & UPON THE EXPRESS CONDITION THAT IT WILL NOT BE USED DIRECTLY OR INDIRECTLY IN ANY WAY DETRIMENTAL ARE FURNISHED FOR THE SOLE INTENT OF APPROVAL & INSTALLING PRODUCT SUPPLIED BY HALDEMAN-HOMME, INC.
HALDEMAN-HOMME, INC. DOES NOT GUARANTEE THEIR ACCURACY TO, NOR WARRANT THEIR FITNESS FOR USE BY OTHERS.
PROJECT MANAGER: OLIN VALENTINE
PHONE: (303) 867-0494
OVALENTINE@HALDEMANHOMME.COM
HALDEMAN-HOMME, INC.
ROCKY MOUNTAIN LAB DIVISION
8676 CONCORD CENTER DRIVE
ENGLEWOOD, COLORADO 80112
PHONE: (303) 237-1333
Cator, Ruma & Associates 896 Tabor Street, Lakewood, CO 80401 Contact:
CORP. OPERATIONS MGR: JEFF ANDERSON
PHONE: (303) 867-0484
JANDERSON@HALDEMANHOMME.COM
OPERATIONS MANAGER: BILL TOLLEY
PHONE: (303) 867-0482
BTOLLEY@HALDEMANHOMME.COM
CAD ENGINEER: LES PHELPS
PHONE: (612) 462-7182
LPHELPS@HALDEMANHOMME.COM
INSTALLATION MANAGER: RANDY RUTLEDGE
PHONE: (303) 867-0480
RRUTLEDGE@HALDEMANHOMME.COM
JOINT VENTURE TEAM
EPOXYN PRODUCTS - LABORATORY WORKSURFACES & SINKS
500 EAST 16TH STREET, MOUNTAIN HOME, ARKANSAS 72653
HAMILTON SCIENTIFIC - LABORATORY FURNITURE
1716 LAWRENCE DRIVE, STE 1, DE PERE, WISCONSIN 54115
KLOPPENBERG & COMPANY - LABORATORY FIXTURES
2627 W OXFORD AVENUE, ENGLEWOOD, COLORADO 80110
SHEET LEGEND
H&l Architecture 1755 Blake Street, STE 400 Denver, CO 80202 Contact:
S.A. Micro, Inc.
4582 Ulster Street Pkwy, STE 300 Denver, CO 80237 Contact:
SUBMITTED FOR APPROVAL
SUBMITTED FOR DIMENSIONS
FABRICATION / INSTALL SET
CONSTRUCTION DRAWINGS
DESIGN / DEVELOPMENT
RE-SUBMITTED FOR APPROVAL
SHEET SHEET DESCRIPTION
COVER PROJECT COVER
INDEX DRAWING INDEX
DN DRAWING NOTES
DS DRAWING SCHEDULES
CO CASEWORK OPTIONS
CL CASEWORK LIBRARY
CP CASEWORK PLANS
CE CASEWORK ELEVATIONS
CS CASEWORK SECTIONS
CD CASEWORK DETAILS
APPROVAL STAMP
COMPANY: EPOXY RESIN COUNTER TOPS
03.CP0.01
BUILDING NUMBER
SHEET TYPE - SEE LEGEND
BUILDING LEVEL
SEQUENTIAL NUMBER
SHEET NUMBERING
PROJECT ENGINEER:
SARAH HARTSFIELD, LEED AP BD+C
MOBILE: (202) 369-4098
EMAIL: SARAH.HARTSFIELD@KIEWITTURNER.COM
EXAMPLE SHEET NUMBER
LABORATORY CASEWORK & ACCESSORY SUBMITTAL FOR:
05-IBN INPATIENT BUILDING
(NORTH)
PROJECT MANAGER - LAB CASEWORK & EQUIPMENT
MARK JOHNSON
MOBILE:
EMAIL: MARK.JOHNSON@KIEWITTURNER.COM
BUILDING: 05-IBN
PROJECT MANAGER
LAURA PRENDERGAST
MOBILE:
EMAIL:
5/13/2014 8:48:55 AM
A
L
I G
N
A
L
I G
N
A L I G
N
RB
RA
EJ
UP
DN
05-01-ST1
STAIR
05-01-RAR1-08
PAT STOR
05-01-RAR1-02
WAIT
05-01-RAR1-03
CONF
05-01-RBR1-02
PHARMACY
05.CE1.01
HH#540
TABLE
CEILING MOUNTED
R2
05-01-RAR1-07
CORRIDOR
05-01-RAR1-06
DINING/SERVING
05-01-RAR1-03
CONF
05-01-RAR1-04
STORAGE
05-01-RAR1-05
MULTIPURPOSE
05-01-RAR1-07
CORRIDOR
05-01-RAR1-10
SERVERY
05-01-ST1
STAIR
05-01-RAR1-08
PAT STOR
05-01-RAR1-02
WAIT
05-01-RAR1-03
CONF
05-01-RAR1-04
STORAGE
HH#540
TABLE
CEILING MOUNTED
HH#540
TABLE
CEILING MOUNTED
HH#540
TABLE
CEILING MOUNTED
HH#540
TABLE
CEILING MOUNTED
HH#540
TABLE
CEILING MOUNTED
6'-21 2" Verify
14'-0" Verify
'-0
Ve ri fy
'-0
Ve ri fy
7' -0
Ve ri fy
7' -0
Ve ri fy
7' -0
Ve ri fy
7'-31 8" Verify
ARCHITECT NOTE:
ADVISE CONTROL SWITCH LOCATION FOR
SUSPENDED (CEILING MOUNTED) TABLE LIFTS.
REVIEW LIGHTING LAYOUT AS SOME LIGHTS MAY
CONFLICT WITH TABLES AS CURRENTLY SHOWN ON
THE ELECTRICAL DRAWINGS.
DATE
DRAWN
SCALE
NOMINAL
PROJECT
PROJECT
MANAGER
ARCHITECT/ENGINEER
HALDEMAN-HOMME, INC
“Exceeding Customer Expectations Since 1924 ”
05.CP1.0305-IBN LEVEL 01 - AREA C FLOOR PLAN
HH32959
LDP
05/12/14
1/16"=1'-0"
ORV
H+L-SOM | CRA-SAM
-11 12 08 09 13
03040506
Key Plan
BUILDING IDENTIFICATION:
05 - IBN INPATIENT BUILDING (NORTH)
N
PARTIAL FLOOR PLAN FOR:
05-IBN, LEVEL 01 - AREA C
Reference Architectural Plan Sheet: 05.AI.401-C
A B
C
5/13/2014 8:49:35 AM
JSN # U4183
Architect - Please see VA RFI#4436 for questions and clarifications with the coordination of the suspended tables.
E
RE
R2
R1
05-03-D3-H1
CHUTE
05-03-D2-06
FOOD CART
ALCOVE
05-03-D1-04
PATIENT RM
05-03-RDR1-02
PAT TLT
05-03-RDR1-04
PATIENT RM
05-03-D3-03B
OFFICE
05-03-D3-05
OFFICE
05-03-D2-08
STAFF
LOUNGE/LOCKERS
05-03-C2-03
CORRIDOR
J
H
G
F
E
RG
RH
RJ
RF
R2
R1
K
05-03-F3-E2
ELEC
05-03-F2-T2
DATA / TELECOMM
05-03-ST2
STAIR
05-03-J1-01
TERRACE
05-03-RER1-04
PATIENT RM
05-03-RHR1-01
POS PRES
PATIENT RM
05-03-RER1-01
PATIENT RM, NEG
PRES
05-03-H1-04
ORTHO CAST
STOR
05-03-E2-03
MED
05-03-F1-01
PATIENT RM, NEG
PRES
05-03-H1-01
PATIENT RM
05-03-E1-01
PATIENT RM, NEG
PRES
05-03-E1-02
PAT TLT
05-03-E1-03
PAT TLT
05-03-E1-04
PATIENT RM
05-03-F1-02
PAT TLT
05-03-F1-03
PAT TLT
05-03-F1-04
PATIENT RM
05-03-G1-01
PATIENT RM
05-03-G1-02
PAT TLT
05-03-G1-03
PAT TLT
05-03-G1-04
PATIENT RM
05-03-H1-02
PAT TLT
05-03-RHR1-02
POS PRES
ANTEROOM
05-03-RHR1-03
PAT TLT
05-03-H2-01
NURSE
SUBSTATION
05-03-F2-02
EQUIP STOR
05-03-E3-06
OFFICE
05-03-F3-02
HAC
05-03-RGR1-04
PATIENT RM
05-03-RGR1-02
PAT TLT
05-03-RGR1-03
PAT TLT
05-03-RGR1-01
PATIENT RM
05-03-RFR1-02
PAT TLT
05-03-RFR1-03
PAT TLT
05-03-RFR1-01
PATIENT RM
05-03-RER1-02
PAT TLT
05-03-RER1-03
PAT TLT
05-03-G2-02
LIVING/MULTIPURPOSE
05-03-G2-01
APARTMENT
05-03-E3-04
CLEAN LINEN
05-03-E2-05
CLEAN UTIL
05-03-E2-06
SOILED UTIL
05-03-E2-08
NOURISH
05-03-E2-02
NURSE STATION
05-03-E2-09
MED GAS STOR
05-03-F2-03
LAUNDRY
05-03-G2-03
DINING
05-03-F3-03
X-RAY MACH
ALCOVE
05-03-RHR1-04
OFFICE
05-03-E3-06B
OFFICE
05-03-E3-05
NURSE STATION
05-03-E2-01
CONSULT
05-03-RFR1-04
PATIENT RM
05-03-F3-01
CORRIDOR
05-03-H3-01
TLT
05-03-H1-03
STAFF TLT
05-03-E2-06B
CRASH CART
ALCOVE
05-03-E3-05A
NURSE
STATION_STOR
05-03-E2-02A
NURSE
STATION_STOR
05-03-G2-01C
APARTMENT_STOR
05.CE3.01
05.CE3.02
HH#559
RACK, STORAGE
CYLINDER GAS
HH#541
TABLE
CEILING MOUNTED
HH#542
TABLE
CEILING MOUNTED
8'-0" Verify
6'-0" Verify
6'-8 9 16"
Verify
4' -0
Ve ri fy
9'-0" Verify
HH#542
TABLE
CEILING MOUNTED
HH#097
HEADWALL
HH#098
HEADWALL
HH#099
HEADWALL
HH#100
HEADWALL
HH#101
HEADWALL
HH#102
HEADWALL
HH#103
HEADWALL
HH#104
HEADWALL
HH#112
HEADWALL
HH#113
HEADWALL
HH#114
HEADWALL
HH#115
HEADWALL
HH#116
HEADWALL
HH#117
HEADWALL
HH#118
HEADWALL
HH#119
HEADWALL
HH#559
RACK, STORAGE
CYLINDER GAS
(X2)
11 12 08 09 13
03040506
Key Plan
BUILDING IDENTIFICATION:
05 - IBN INPATIENT BUILDING (NORTH)
DATE
DRAWN
SCALE
NOMINAL
PROJECT
PROJECT
MANAGER
ARCHITECT/ENGINEER
HALDEMAN-HOMME, INC
“Exceeding Customer Expectations Since 1924 ”
05.CP3.0205-IBN LEVEL 03 - AREA B FLOOR PLAN
HH32959
LDP
05/12/14
1/16"=1'-0"
ORV
H+L-SOM | CRA-SAM
ARCHITECTS | ENGINEERS
N
PARTIAL FLOOR PLAN FOR:
05-IBN, LEVEL 03 - AREA B
Reference Architectural Plan Sheet: 05.AI.403-B
A B
5/13/2014 8:50:19 AM
JSN # U4183
See VA RFI 4436 for location of suspended tables
Fax: 303.930.9001
303.930.9000Tel:
Kiewit - Turner a Joint Venture
Suite A-300 7200 S. Alton Way
Englewood, CO 80112
Job: 15387 - Replacement Medical Center Facility
Product Data
Sample
Other
Shop Drawing
Resubmittal
First Submittal X
VA Proj #:
To: H+L Architecture 1755 Blake Street
Suite 400
Denver, CO 80202
DESCRIPTIONSpecificationSUBMITTAL
ItemQuantity Section Sub./SupplierNo. Mfgr.
ACTION
DCBA E
Kiewit Submittal No. 22 13 00-01
Architect's Submittal No. 00008
Review Cycle: 001
Attn: Chuck Adkisson
1 SWPPP - CBS & RFP #3 OnlyKiewit - Turner a
Joint Venture
01 573
ACTION TAKEN
CONTRACTOR'S SIGNATURE:
CONTRACTOR'S NOTES:
DATE: 7/12/2011
Reviewed Only for Revisions to
Reviewed: Incorporate Changes
Reviewed=
A
B
C
Previous Submittal
Revise and Resubmit=D
Rejected =E
ARCHITECT/ENGINEER RESPONSE:
REMARKS:
BY: DATE:
Expedition f_sb_pks_01a
VA101CFM-C-0100
Cc: Tim Pogany, U.S. Dept. of Veterans Affairs
Received By ___________________
Date _______________
12 56 70.11
X
GENO&M_Suspended Tables
X
HaldemanHomme, Inc.
12 56 70.11002
10/07/2016
10/21/2016
Kiewit-Turner Submittal No.
COE 1
REQUESTED RETURN DATE:
Kevin Lindsey, U.S. Dept. of Veterans Affairs
VA101F-15-C-0005
13611 E. Colfax Avenue 2nd Floor Aurora, CO 80045
DEPARTMENT OF THE ARMY
Omaha District Corps of Engineers 13611 East Colfax Avenue 2nd Floor Aurora, CO 80045
W9128F-16-C-0003
Peter Sturdivant
These shop drawings/submittals have been reviewed in accordance with the provisions of the Contract Documents. Kiewit-Turner's review shall not serve to relieve Subcontractors or Suppliers of contractual responsibilities for any error or deviation from contract and subcontract requirements.
KIEWIT-TURNER
a Joint Venture
REVIEWED - NO COMMENTS MADE
REVIEWED WITH COMMENTS
RESUBMITTAL REQUIRED
DATE SIGNED
SUBMITTAL #:
12 56 70.11-002
09/29/16 Mark S. Johnson
Kiewit-Turner a Joint Venture
7200 S. Alton Way, Suite A-300, Englewood, CO 80112
Phone: 303-930-9000 FAX: 303-930-9001
Project Name:
Subcontractor Name: Submittal Date:
Contact Name: E-mail: Return By Date:
Contact Phone(s): Review Days:
Number: Name:
O&M Manuals
Reviewed By Date 9/29/2016
Submittal is in Compliance
Submittal is in Compliance with Variances from Specifications
Signature
SUBMITTAL INDEX & COVER SHEET
Department of Veteran's Affairs
Replacement Medical Center
Haldeman Homme 09/29/16
Bill Tolley btolley@haldemanhomme.com
303-867-0482
Specification Section: 12 56 70.11 Suspended Tables
S p e c
S u b m it ta l
P a ra g ra p h
S p e c
P ro d u c t
P a ra g ra p h
S p e c if ie d o r
L is te d
M a n u fa c tu re r?
M e e ts
A ll
S p e c
R e q u ir e m e n ts
E x c e p ti o n s o r
V a ri a n c e s f ro m
S p e c
A p p ro v e r
In fo rm a ti o n
N e e d e d
I n
T h is P a c k a g e
Submittal Type
Submittal Item Description Manufacturer
T Fabco
Mark Johnson
SubmittalIndexForm_041009 Page 1 of 1
Kiewit - Turner ^^^^^_^^^^^^aJointVenture
Division 12 Furnishings Section 12 56 70.11 Suspended Tables
Suspended Tables No Operations & Maintenance Manuals
Specified Haldeman Homme, Inc.
T-fabco Corporation presents
Suspended table submittals
Project: V A Denver Replacement Medical Facility
Location: Aurora
Architect:
Contractor: Haldeman - Homme, Inc.
Contract Number: 32959-5719
Date:
Revision Date(s) :
Prepared By : Jerry Harburg
Architect Approval :
Approval Date:
Page of
P. O. Box 1436 I Gibsonton, FL 33534 Phone (877) 738-2080 I Fax (813) 671-1865 www.uptable.com
TYPICAL DECK MOUNT FRAME
liny
WELD TO G.C. SUPPLIED
IMLANTS .ANGLES OR
ATTACH WITH RAWL
PLUGS
WELDED 3”X1/4” STEEL
MOUNTING FRAME
24"
18"
I m r
FIELD VERIFY
J
AF3024
Mounting Frame and mounting bolts by T-fabco
32”
26”
E iCn
4" MINIMUM
‘ f
LJ
L 2” s s
END VIEW
Hung Ceiling Track ------- /
Table motor housing
SIDE VIEW
CEILING SUSPENDED TABLE AF 1000E
DISTANCE FROM
HUNG CEILING TO
FLOOR=
| 12 56 70.11-01 - IBN - Ceiling Mounted Tables |
| 12 56 70.11-02 - GEN_OandM_Haldeman_Homme_Suspended_Tables |
| 12 56 70.11 Suspended Tables |
photos
File details come from the government source that posted it. Updated .