03-03 Room Elevations.pdf

PDF 1 MB Posted

Attached to
Z2DA--554-23-103 Replace OR Booms (VA-23-00012203)
Solicitation number
36C25923R0033
Issued by

About this file

This document package includes interior elevation drawings and specifications for a replacement medical center facility project. The drawings depict millwork, casework, fixtures and equipment for multiple procedure, diagnostic and treatment rooms on level three. Key details include plastic laminate and solid surface materials for countertops and casework, dimensions for built-in cabinets and fixtures, and notes regarding finishes, equipment connections and mounting details. The related federal contract opportunity is solicitation number 36C25923R0033 to replace operating room booms for the Veterans Affairs Veterans Health Administration facility in VISN 19. The requirement includes replacement of OR booms for the 554-23-103 project to replace the medical center facility. No further details are provided on pricing, response dates or other contractual terms.

View the file

Other files

File Type Posted
36C25923R0033 0006.docx DOCX document
OR Isolation Panels - Project 554-23-103 Replace OR Booms.pdf PDF
attendance 1 of 2 Feb 24 2023.pdf PDF
36C25923R0033 0005.docx DOCX document
attendance 2 of 2 Feb 24 2023.pdf PDF
Site Visit 2 Meeting Doc.docx DOCX document
03 Lighting.pdf PDF
03 Power.pdf PDF
36C25923R0033 0004.docx DOCX document
03 Equip and Lighting Mounting.pdf PDF
03 Structural Steel.pdf PDF
03 Plumb Med Gas.pdf PDF
03 Equipment.pdf PDF
03 HVAC mechanical.pdf PDF
03 Reflected Ceiling Plans.pdf PDF
36C25923R0033 0003.docx DOCX document
36C25923R0033 0002.docx DOCX document
Site Visit Meeting Doc.docx DOCX document
attendance 1 of 2.pdf PDF
SOW r2 proj 554-23-103 Replace OR Booms.docx DOCX document
attendance 2 of 2.pdf PDF
03_DAT_Med Equip Support Steel_Unistrut_As-Builts - opt.pdf PDF
36C25923R0033 0001.docx DOCX document
Wage Determination CO20230015 1 13 2023.pdf PDF
36C25923R0033_1.docx DOCX document
SPECS proj 554-23-103 Replace OR Booms.pdf PDF
S02 Past Performance Questionnaire.docx DOCX document
Drawings proj 554-23-103.pdf PDF
Show all 28

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

U4167

A5108

U4148

M3070

10"

F3200.A

U4167

U4233

PANEL LINE

ISOLATION

MONITORIN

G

RE: MECH

2' - 0"

CB

2' - 6" 2' - 6" 2' - 6" 2' - 6" 2' - 6"

A5075

A5080

A5108

A1012

WF

1" 2' - 6" 2' - 6" 2' - 6"

1' - 3"

2' 6"

1' 8"

3' 0"

U4042

E0912

W1 W1 W1

B1 B15 B1 B1 B1

M1832

A5107

COUNTERTOP AS

SCHEDULED W/ 4"

HIGH

BACKSPLASH

PLAM JOINT IN

FASCIA PANEL

PLAM FACED

FASCIA PANEL

(A5080) 4' - 9"

E0918

E0912

E1500

U4053

5"5"5" 7' - 4"

F3200.A 1' - 9"

A5108

M3070

PANEL LINE

ISOLATION

MONITORING

RE: ELEC

BO

T O F

PA

N

EL

2' 6"

A5108

A5080

A5075

(A5080) 2"

2' - 6"2' - 6"WF

1"

2' - 6"2' - 6"2' - 6"

BF

1"

3' 0"

1' 8"

2' 6"

W1 W1

B1 B1 B15

M1832

COUNTERTOP AS

SCHEDULED W/ 4"

HIGH BACKSPLASH

PLAM FACED

FASCIA PANEL

CODE BLUE A5107

U4259

A1012

U4167

(B O T O F U

3' 0"

11' - 10"

U4053

M1801

INTERCOM

4' - 8"

F3200.A

A5075A5080

A5108

A5107

1' - 4" (A5107) 2' - 0"

(A , U

3' 6"

X6185.A15

X6185.A16

(U4017) 1' - 11"

(A5108) 1' - 2"

U4017

U4167

3' - 4"5"5"5"8"6"8"

X6185.A8

E0948

INTERCO

MCODE BLUE

NURSE

CALL

U4042U4042

5' - 0" 2' - 6" 4' - 6" 3' - 8"

PANEL LINE

ISOLATION

MONITORING

RE: ELEC

(U

7' 0"

U4024U4024

X6185.A8 X6185.A9

X6185.A10 X6185.A12

U4148

X6185.A13X6185.A9

X6185.A8

OPEN

BEYOND

U4022

X3150

F3050

U4022

U4005

U4167

1' - 10" 2' - 9" 3' - 4"

X3150

WP04

WP04 WP04WP04WP04

(T O P O F X3

0)

5' 4"

PUSH PLATE

ACTIVATOR

A5080

A5075

A1012

M1802 U4237

F3200.A

E0954

E0912E0912E0912E0954 M1801

F0465

M3070M3110

8"E1500

WP06WP06 WP06 WP04 WP04

A1012

A5107 M8607.A

A5107

U4053

M1801

U4148

E0948

1' 0"

(B O T O F U

3' 0"

U4017

3' - 7 1/2" 2' - 0" 2' - 0" 1' - 8" 1' - 0"

5"5"5" 1' - 0"1' - 3"1' - 3"1' - 6" 3' - 0"

WASTE MANAGMENT

SYSTEM WALL BOX

(P-811)

TO

D R

AI

N

5"

C O N N

EC

TI

O N

SURGICAL LIGHT

CONTROLS

A1012

M8607.A U4042U4042 A5107

U4017

U4167

2' - 6" 3' - 6" 4' - 0"

U4053U4053

1' - 8" 1' - 0" 5"5"5" 9' - 8"

WASTE MANAGMENT

SYSTEM WALL BOX

(P-811)

TO

D R

AI

N

5"

C O N N

EC

TI

O

N

(U

7' 0"

A1012

AUTOMATIC

OPERATOR PUSH

PLATE

M8607.A

A5107 M1801

U4056

M3070

5' - 8"

7' - 2" 1' - 0" 5"5"5" 1' - 0"U4167

WASTE MANAGEMENT

SYSTEM WALL BOX (P-811)

U4024

5"

OPEN TO

BEYOND

4' - 6"

EQEQ

TO

B O T U

3' 0"

2' 0" 1' 0"

A5

1' 6"

BF

1 1/2" 2' - 6" 2' - 6" 2' - 6" 2' - 6" 2' - 6"

F3200.A

A1012

A5075

A5080

A5108

1 1/2" 2' - 6" 2' - 6" 2' - 6" 2' - 6" 2' - 6"

2' 4"

2' 6"

1' 8"

3' 0"

A5107

W1 W1 W1 W1 W1

B1 B1 B1 B1 B15

M1832

U4148

L0100

PLAM FACED

FASCIA PANEL

PLAM JOINT IN

FASCIA PANEL

COUNTERTOP

AS SCHEDULED

W/ 4" HIGH

BACKSPLASH

U4017

E0948E09481' - 1" 2' - 0"

AT ANGLE

WALL

EXHAUST

GRILLE

RE: MECH

A1012

M1802

M1801

M3070

AT ANGLE

WALL

7' - 0"

U4167

A5108

A5107

U4167

U4259

PANEL LINE

ISOLATION

MONITORING

RE: ELEC

EXHAUST

GRILLE

RE: MECH

6' - 5"

9' - 8" 1' - 0" 5"

WASTE MANAGMENT

SYSTEM WALL BOX (P-811)

TO

D R

AI

N

5"

C O N N

EC

TI

O N

X4122

13' - 0"

1' - 4"

KE

YB

O

AR

D 3' 0"

1. REFER TO SHEET 00.AI.002 FOR TYPICAL MOUNTING HEIGHTS

LEGEND.

2. REFER TO SHEET 00.AI.002 FOR ANNOTATION AND SYMBOL LEGENDS.

3. REFER TO SHEETS XX.AI.701, XX.AI.702, AND XX.AI.702-A FOR BASE

AND

WALL CABINET TYPES AND DETAILS.

4. REFER TO MILLWORK FINISH SCHEDULE, SPECIFICATION SECTIONS

0640, FOR COUNTER TOP AND MILLWORK FINISHES AND SOLID

SURFACE SINK TYPES. REFER TO SHEET XX.AI.716 FOR LAB,

PHARMACY, AND STAINLESS STEEL CASEWORK LEGEND AND

ELEVATIONS.

5. PROVIDE PLASTIC LAMINATE FASCIA ABOVE ALL WALL CABINETS

UNLESS NOTED OTHERWISE.

6. REFER TO EQUIPMENT SCHEDULE, SPECIFICATION 110670, FOR

EQUIPMENT INDICATED BY JSN NUMBER.

7. PROVIDE ALUMINUM COUNTER SUPPORT BRACKETS AT 32" O.C. AT

ALL

OPEN COUNTERTOPS AS REQUIRED UNLESS NOTED OTHERWISE.

8. AT OPEN ENDED COUNTERTOPS, PROVIDE FIRST COUNTER

SUPPORT

BRACKET AT 4" O.C. FROM COUNTER EDGE.

9. PROVIDE END SPLASH AT COUNTERTOP WHERE BACKSPLASH

OCCURS AT ADJACENT WALL, TYPICAL.

10. REFER TO SHEET 00.AI.002 FOR TYPICAL TILE PATTERN DETAIL.

11. REFER TO AI.10x SHEETS FOR WINDOW ELEVATION TAGS.

12. REFER TO MARKERBOARD SCHEDULE IN THE SPECIFICATIONS FOR

SIZES.

13. TURN COUNTERTOP DOWN AT CHANGE IN ELEVATION, TYPICAL.

14. LOCK LOCATIONS AT BASE AND UPPER CABINETS TO BE

COORDINATED

WITH RESIDENT ENGINEER.

15. GROMMET LOCATIONS TO BE COORDINATED WITH RESIDENT

ENGINEER.

16. REFER TO XX.AI.731 FOR BACKING PLATE SCHEDULE AND DETAIL.

INTERIOR ELEVATION NOTES

11 12 08 09 13

03040506

Drawing Number

Building Number

Project NumberProject Title

Location

Date Checked Drawn

Drawing Title

Approved: Project Director

Key PlanCONSULTANTS:

DateRevisions

1 2 3 4 5 6 7 8 9 10 11 12

D

C

B

A

554-501REPLACEMENT MEDICAL CENTER

FACILITY, EASTERN COLORADO

HEALTH CARE SYSTEM

AURORA, COLORADO

N

C O N

R

ES

D

AT

IB

S

IB

N

EN

C C

LC

C

BN

C

BC

C

BS

PS

N

PV

N

PV

S

13 14

1 2 3 4 5 6 7 8 9 10 11 12 13 14

E on e qu ar te r i nc h on e fo ot

OFFICE OF

CONSTRUCTION

AND FACILITIES

MANAGEMENT

ARCHITECT/ENGINEERS:Professional Seal

9/ /2 :0 5:

A M

C :\U se rs \C

AD

U se r 1 \D oc um en ts \A I-D

AT

_J es sy .M an ch a5

AV

.rv t

03.AI.563

LEVEL 3 INTERIOR ELEVATIONS -

DIGESTIVE DISEASES

DIAGNOSTIC AND TREATMENT

08/31/2012

1/4" 1'-0"1 03-03-F9-03 - PROCEDURE - N

1/4" 1'-0"3 03-03-F9-03 - PROCEDURE - S

1/4" 1'-0"2 03-03-F9-03 - PROCEDURE - W

1/4" 1'-0"5

03-03-F10-03 - PROCEDURE -

N

1/4" 1'-0"7

03-03-F10-03 - PROCEDURE -

S

1/4" 1'-0"6

03-03-F10-03 - PROCEDURE -

W

1/4" 1'-0"9

03-03-E10-03 - PROCEDURE -

N

1/4" 1'-0"11

03-03-E10-03 - PROCEDURE -

S

1/4" 1'-0"10

03-03-E10-03 - PROCEDURE -

W

1/4" 1'-0"13

03-03-E10-01 - DIGESTIVE

DISEASES CORE - N

1/4" 1'-0"14

03-03-E10-01 - DIGESTIVE

DISEASES CORE - S

1/4" 1'-0"4 03-03-F9-03 - PROCEDURE - E

1/4" 1'-0"8

03-03-F10-03 - PROCEDURE -

E

1/4" 1'-0"12

03-03-E10-03 - PROCEDURE -

E

1/4" 1'-0"15 03-03-E10-02 -

BRONCHOSCOPY - N

1/4" 1'-0"16 03-03-E10-02 -

BRONCHOSCOPY - W

1/4" 1'-0"17 03-03-E10-02 -

BRONCHOSCOPY - S

1/4" 1'-0"18 03-03-E10-02 -

BRONCHOSCOPY - E

F3200.AA4015

F3050

A1014

A5108

A5107

SOLID SURFACE WALL MOUNTED

COUNTERTOP W/ 4" HIGH

BACKSPLASH ON STAINLESS

STEEL WALL BRACKETS, ANGLES &

LEGS.

RE: 3/XX.AI.715-A

1' - 3"

PANEL LINE

ISOLATION

MONITORING

RE: ELECRETURN

GRILLE

RE: MECH

RETURN

GRILLE

RE: MECH

3' - 6"3' - 0"1' - 6"4' - 2"

2' - 0"1' - 0"1' - 0"

SURGICAL

LIGHT

CONTROLS

OR INTEGRATION

SYSTEM

MONITOR

1' 0"

2' 6"

1' 6"

3' 0"

2' - 0" 2' - 0"

ROOM LIGHT

CONTROLS

1' - 6"

AUTO OPERATOR

PUSH PLATE

A5107

A5108

U4053

M1801

E0954

F3050

2' - 6" 2' - 0" 5"5"

1' - 0"

3' 6"

5' 0"

TO

K

EY

BO

AR

D 3' 0"

OR INTEGRATION

SYSTEM

MONITOR

U4135X6190.A10X6190.A10

COORD FINAL LOCATION

W OWNER AND VENDOR

REP

A5107

A5108

A1012

RETURN

GRILLE

RE: MECH

RETURN

GRILLE

RE: MECH

RECESSED FEC

1' - 3"

1' - 6"

1' - 3"

2' 0"

A1130

1' 6" 6"

1' 0"

1' 6"

2' 6"

U4022 1' - 7" 2' - 3"

SSA18

PANEL LINE

ISOLATION

MONITORING

RE: ELEC

RETURN

GRILLE

RE: MECH

RETURN

GRILLE

RE: MECH

1' - 3" 6' - 0" 2' - 6" 3' - 0"

TO CL J-BOX

4' - 8"

2' 0"

14x14x4 ELEC JUNCTION BOX

WITH (4) 2 1/2" CONDUIT TO

14x14x4 JUNCTION BOX ABOVE

OR CEILING

F3200.A

4"2' - 8"2' - 8"2' - 8"

2' - 2 1/2"

ALUMINUM

COUNTER SUPPORT

BRACKETS @ 32"

O.C. MAX (PAINT)

2'-6" DEEP WALL

MOUNTED

COUNTERTOP AS

SCHEDULED W/ 4" HIGH

BACKSPLASH.

B7

3' 0" 4' 6"

X6190.A11

WALL DUCT

RE: VENDOR

DWGS10' - 6"

2' - 11"1' - 6"2' - 5"2' - 11"

A5075

A5080

SSDT35 SSDA29 SSAE18 SSDT35

R6010.AM4825

U4217

3' 1/ 4"

2'-6" DEEP WALL

MOUNTED

COUNTERTOP AS

SCHEDULED W/ 4"

HIGH BACKSPLASH

6' - 6"

E0906.A

U4049

L1095

E1500

F3200.A

U4167

A1012

M1802 (M

3' 6"

M1801

CONTRACTOR

FURNISH AND

INSTALL LASER

PROTECTIVE

SHADE AT

WINDOW

E0903.A

A1012

A5107

A5108

U4210

OCCURS IN OR 03-03-

G2-04 ONLY, FOR DA VINCI

SYSTEM

1' 6"

9' - 0"1' - 6"2' - 0"1' - 6"

14x14x4 ELEC JUNCTION

BOX WITH (4) 2 1/2"

CONDUIT TO 14x14x4

JUNCTION BOX ABOVE OR

CEILING

1' - 11"

A4015

F3200.A F3050

A1014

ROOM LIGHT

CONTROL SWITCHES

AUTOMATIC OPERATOR

OVERRIDE KEY SWITCH

RE: DOOR HARDWARE

SURGICAL LIGHT

CONTROLS

THERMOSTAT CONTROL

CONTRACTOR FURNISH

AND INSTALL LASER

PROTECTIVE SHADE AT

WINDOW RE: SPECS

3' 0"

SOLID SURFACE

COUNTERTOP

ON SSTL WALL

BRACKETS,

ANGLES &

LEGS;

RE:3/AI.715-A

F2020

7' - 6"9"3' - 3"2' - 0"

1' - 0"1' - 0"1' - 0"

LINE OF WALL AT

RETURN GRILL

WHERE OCCURS

4' 6"

OR SYSTEM

INTEGRATION

MONITOR 55"

3' 6"

1' 0"

EQ

5"5"

EQ

INTERCOM

CODE BLUE

A1130

U4022

3' - 3"

2' - 6 1/2" 1' - 7" 2' - 2" (U4022) 2' - 5"

SOLID SURFACE COUNTER

W/ 4" BACKSPLASH ON SSTL

WALL BRACKETS, ANGLES &

LEGS RE: 9/XX.AI.715-B

1' 6"6"

1' 0"

1' 6"

2' 6"

SSA18

RETURN GRILLE

RE: MECH

RETURN GRILLE

RE: MECH

(B O T O F A1

0)

4' 0"

SSTL SLOPED TOP

6 PORT DATA ONLY

AT OR 03-03-G2-04

FOR DAVINCI

SYSTEM

(3) 20A CRITICAL ELEC

ONLY AT OR 03-03-

G2-04 FOR DAVINCI

SYSTEM. REFER TO

ELEC DWGS FOR

CIRCUITS

14Hx14Dx4D ELEC JUNCTION BOX WITH (4) 2 1/2" CONDUIT TO 14x14x4

JUNCTION BOX ABOVE OR CEILING2-GANG BOXES FOR

SURGICAL LIGHT CAMERAS

5' - 0" 1' - 3" 7' - 3" 1' - 0"

EQ EQ

AT COLUMN

1' - 3"

A5107

A5108

LOCATION FOR

A5107 AND A5108 AT

OR 03-03-G2-04 ONLY

1' - 3" 3' - 6"

E0906

M3070

5"5"5" 1' - 2" 5"

4' 0"

3' - 6"

EXAM LIGHT

WALL CONTROL

F3200.A

E0906

U4167

A5108 E0906

E0915

U4167

E1500

3' 0"

6" 2' - 8" 3' - 6"

RECESSED

ALUMINUM COUNTER

SUPPORT BRACKETS

@ 32" O.C. MAX

(PAINT)

2'-6" DEEP WALL

MOUNTED

COUNTERTOP AS

SCHEDULED W/ 4" HIGH

BACKSPLASH

B7

WALL DUCT

RE: VENDOR DWGS

CR1

6' - 8"

E0906.A

U4167

E1500

A5107

A5108

3' - 0"

7' - 0"

PANEL LINE

ISOLATION MONITORING

RE: ELEC

RETURN GRILLE

RE: MECH

RETURN GRILLE

RE: MECH

3' - 0" 10' - 0"

FEC

X4122

OR INTEGRATION

SYSTEM MONITOR

KE

YB

O

AR

D 3' 0"

LASER OUTLET AT 24"

AFF WITH LOCAL

RESET AT 54" AFF RE:

ELEC

ROOM LIGHT

SWITCHES RE: ELEC

AUTO OPERATOR

PUSH PLATE

4' - 8" 2' - 10"

1' - 3"

1' - 3" 5' - 6"

RETURN GRILLE

RE: MECH

RETURN GRILLE

RE: MECH

2' 0"

EQ EQ

(M

3' 6"

M1802

M1801

A5108

A5107

4' 1"

U4148

5"5"5"

10" 1' - 10"

2' - 0" 3' - 0"

U4017M3070

A1014

1. REFER TO SHEET 00.AI.002 FOR TYPICAL MOUNTING HEIGHTS

LEGEND.

2. REFER TO SHEET 00.AI.002 FOR ANNOTATION AND SYMBOL LEGENDS.

3. REFER TO SHEETS XX.AI.701, XX.AI.702, AND XX.AI.702-A FOR BASE

AND

WALL CABINET TYPES AND DETAILS.

4. REFER TO MILLWORK FINISH SCHEDULE, SPECIFICATION SECTIONS

0640, FOR COUNTER TOP AND MILLWORK FINISHES AND SOLID

SURFACE SINK TYPES. REFER TO SHEET XX.AI.716 FOR LAB,

PHARMACY, AND STAINLESS STEEL CASEWORK LEGEND AND

ELEVATIONS.

5. PROVIDE PLASTIC LAMINATE FASCIA ABOVE ALL WALL CABINETS

UNLESS NOTED OTHERWISE.

6. REFER TO EQUIPMENT SCHEDULE, SPECIFICATION 110670, FOR

EQUIPMENT INDICATED BY JSN NUMBER.

7. PROVIDE ALUMINUM COUNTER SUPPORT BRACKETS AT 32" O.C. AT

ALL

OPEN COUNTERTOPS AS REQUIRED UNLESS NOTED OTHERWISE.

8. AT OPEN ENDED COUNTERTOPS, PROVIDE FIRST COUNTER

SUPPORT

BRACKET AT 4" O.C. FROM COUNTER EDGE.

9. PROVIDE END SPLASH AT COUNTERTOP WHERE BACKSPLASH

OCCURS AT ADJACENT WALL, TYPICAL.

10. REFER TO SHEET 00.AI.002 FOR TYPICAL TILE PATTERN DETAIL.

11. REFER TO AI.10x SHEETS FOR WINDOW ELEVATION TAGS.

12. REFER TO MARKERBOARD SCHEDULE IN THE SPECIFICATIONS FOR

SIZES.

13. TURN COUNTERTOP DOWN AT CHANGE IN ELEVATION, TYPICAL.

14. LOCK LOCATIONS AT BASE AND UPPER CABINETS TO BE

COORDINATED

WITH RESIDENT ENGINEER.

15. GROMMET LOCATIONS TO BE COORDINATED WITH RESIDENT

ENGINEER.

16. REFER TO XX.AI.731 FOR BACKING PLATE SCHEDULE AND DETAIL.

INTERIOR ELEVATION NOTES

2' - 11"2' - 11"

SSL35SSL35

RVS01A

SSTL

SLOPED TOP

3' - 0"

5' - 10" 6' - 10"

PANEL LINE

ISOLATION MONITORING

RE: ELEC

RETURN GRILLE

RE: MECH

RETURN GRILLE

RE: MECH

FEC

OR INTEGRATION

SYSTEM MONITOR

LASER OUTLET AT 24"

AFF WITH LOCAL

RESET AT 54" AFF RE:

ELEC

ROOM LIGHT

SWITCHES RE: ELEC

AUTO

OPERATOR

PUSH PLATE

RETURN GRILLE

RE: MECH

RETURN GRILLE

RE: MECH

3' - 0"

3' - 0"

3' - 0"

KE

YB

O

AR

D 3' 0"M O N

IT

O R B R

AC

KE

T

8' 0"

6' - 0"

X4122

M1801

M1801E0117

E0117

1' - 0"1' - 0"

14x14x4 ELEC JUNCTION

BOX WITH (4) 2 1/2"

CONDUIT TO 14x14x4

JUNCTION BOX ABOVE OR

CEILING

U4210

1' 6"

TO

K

EY

BO

AR

D (X

3' 0"

11 12 08 09 13

03040506

Drawing Number

Building Number

Project NumberProject Title

Location

Date Checked Drawn

Drawing Title

Approved: Project Director

Key PlanCONSULTANTS:

DateRevisions

1 2 3 4 5 6 7 8 9 10 11 12

D

C

B

A

554-501REPLACEMENT MEDICAL CENTER

FACILITY, EASTERN COLORADO

HEALTH CARE SYSTEM

AURORA, COLORADO

N

C O N

R

ES

D

AT

IB

S

IB

N

EN

C C

LC

C

BN

C

BC

C

BS

PS

N

PV

N

PV

S

13 14

1 2 3 4 5 6 7 8 9 10 11 12 13 14

E on e qu ar te r i nc h on e fo ot

OFFICE OF

CONSTRUCTION

AND FACILITIES

MANAGEMENT

ARCHITECT/ENGINEERS:Professional Seal

9/ /2 :0 6:

A M

C :\U se rs \C

AD

U se r 1 \D oc um en ts \A I-D

AT

_J es sy .M an ch a5

AV

.rv t

03.AI.565

LEVEL 3 INTERIOR ELEVATIONS -

SURGERY

DIAGNOSTIC AND TREATMENT

08/31/2012

1/4" 1'-0"1 03-03-D2-04 - CVOR - N

1/4" 1'-0"4 03-03-D2-04 - CVOR - E

1/4" 1'-0"3 03-03-D2-04 - CVOR - S

1/4" 1'-0"2 03-03-D2-04 - CVOR - W

1/4" 1'-0"5 03-03-E2-04 - CONTROL - N

1/4" 1'-0"7 03-03-E2-03 - PUMP RM - N

1/4" 1'-0"9 03-03-E2-03 - PUMP RM - S

1/4" 1'-0"8 03-03-E2-03 - PUMP RM - W

1/4" 1'-0"11 03-03-G3-02 - OR - N

1/4" 1'-0"13 03-03-G3-02 - OR - S

1/4" 1'-0"12 03-03-G3-02 - OR - W

1/4" 1'-0"15 03-03-D9-05 - PROCEDURE - N

1/4" 1'-0"17 03-03-D9-05 - PROCEDURE - S

1/4" 1'-0"16 03-03-D9-05 - PROCEDURE - W

1/4" 1'-0"6 03-03-E2-04 - CONTROL - W

1/4" 1'-0"10 03-03-E2-03 - PUMP RM - E

1/4" 1'-0"14 03-03-G3-02 - OR - E

1/4" 1'-0"18 03-03-D9-05 - PROCEDURE - E

1/4" 1'-0"19 03-03-H3-04 - ORTHO STOR - N

1/4" 1'-0"20 03-03-G2-04 - OR - W

1/4" 1'-0"6A 03-03-E2-04 - CONTROL - S

A5180

M1801

11" 4' - 1" 4' - 0"

U4053

U4024 A1105

A5107 A5108

M4100

2' 0"

6"1' 6"

1' 6"

1' - 3" 1' - 3"1' - 10"

1' - 0"

6"9"9"6"2' - 10"1' - 1"

9' - 0"

TYPICAL PACU1 HEADWALL LAYOUT

N N

M7845

NC CODE BLUE

NC PATIENT STATION

NC AUXILIARY JACKS

NC BED INTERFACE

RVS02

NC AUXILIARY JACKS

BIOMED

OUTLET BY VA

TEL/DATA

OF BED

A6046 M0506

F3050

9' - 0"

2' 0"

1' 0"

1' 6"

5' 6"

TO HEADWALL C.L.

5' - 7"

1' - 0"

1' - 10" 6" 9"

1' - 3"

EQ

WALL PROTECTION

4' - 0" EQ

A1105

M1801

A1105U4024 U4053

O F H

EA

D W

AL

L

AL

IG

N T O T O P

NC CODE BLUE

NC PATIENT STATION

NC AUXILIARYJACKS

NC AUXILIARY JACKS

TEL/ DATA

M7845

NC BED INTERFACE

WALL PROTECTION,

RVS02, VERTICAL GRAIN

BIOMED

OUTLET BY VA

E0948

COORD OUTLET TO

PATIENT LIFT, TYP.

RE: VENDOR DWGS

A5080 U4167

A5108

F3200

U4017A5075

A5107 U4148

SEE FLR PLAN

LIGHT, SEE ELEC.

1' - 6"

3' - 0"

3' 0"

BF

1"3' - 6"

B1 E0954

COUNTERTOP AS

SCHEDULED W/ 4" HIGH

BACKSPLASH

STATION PNEUMATIC

TUBE SYSTEM - SIDE

RISERS

1' - 0" 2' - 6" 2' - 6"

2' 3"

5' 0"

W1 W1

WP06

PLAM FACED

FASCIA PANEL

4' 6"

HALF-HT. PARTITION

F3200.A

U4005

3' 4"

1' 6"

4' - 0" B44

1' - 10 1/2"2' - 6"

WF

1/2"

4' 4"

2'

2' - 0"2' - 6"BF

1/2"

A5075

A5080

W1 W1

B15 B1

COUNTERTOP AS

SCHEDULED W/ 4" HIGH

BACKSPLASH

PLAM FACED

FASCIA PANEL

U4167

U4032

U4148

MOUNTED

COUNTERTOP AS

SCHEDULED W/ 4" HIGH

BACKSPLASH

PLAM FACED

FASCIA PANEL

4' - 0"

XX.AI.793

TYP

COUNTERTOP AS

SCHEDULED

WP04

3' 6"

2'

M3110

COUNTERTOP

AS SCHEDULED

3' 0"

R6200

U4006

ALUM CNTR

SUPPORT

BRACKET

(PAINT)

ALUM WALL

ANGLE

COUNTER

SUPPORT

BRACKETS, (PT)

2' - 6" B7

BO

X

W

AT

ER

2' 0"

ICE MAKER WATER BOX

WITH DRAIN, FILTERS AT

SIDE WALL - GROMMET

THROUGH COUNTERE0954

FOUR TIER

MILLWORK LOCKERS

W/ LOCKS AND

FILLER PANEL. KEY

LOCKS WITH SAME

(20 IND. LOCKERS)

4' - 10" MIN. 5' - 0"

3' 0"

(4 ) E

Q S

PA

C

ES

5' 8"

PLAM FACED

FASCIA PANEL

10"BF

1"

B37

PLAM FACED

FASCIA PANEL

WF

EQ2' - 3"2' - 3"

WF

EQ

W1 W1

2' 3"

5' 0"

1. REFER TO SHEET 00.AI.002 FOR TYPICAL MOUNTING HEIGHTS

LEGEND.

2. REFER TO SHEET 00.AI.002 FOR ANNOTATION AND SYMBOL LEGENDS.

3. REFER TO SHEETS XX.AI.701, XX.AI.702, AND XX.AI.702-A FOR BASE

AND

WALL CABINET TYPES AND DETAILS.

4. REFER TO MILLWORK FINISH SCHEDULE, SPECIFICATION SECTIONS

0640, FOR COUNTER TOP AND MILLWORK FINISHES AND SOLID

SURFACE SINK TYPES. REFER TO SHEET XX.AI.716 FOR LAB,

PHARMACY, AND STAINLESS STEEL CASEWORK LEGEND AND

ELEVATIONS.

5. PROVIDE PLASTIC LAMINATE FASCIA ABOVE ALL WALL CABINETS

UNLESS NOTED OTHERWISE.

6. REFER TO EQUIPMENT SCHEDULE, SPECIFICATION 110670, FOR

EQUIPMENT INDICATED BY JSN NUMBER.

7. PROVIDE ALUMINUM COUNTER SUPPORT BRACKETS AT 32" O.C. AT

ALL

OPEN COUNTERTOPS AS REQUIRED UNLESS NOTED OTHERWISE.

8. AT OPEN ENDED COUNTERTOPS, PROVIDE FIRST COUNTER

SUPPORT

BRACKET AT 4" O.C. FROM COUNTER EDGE.

9. PROVIDE END SPLASH AT COUNTERTOP WHERE BACKSPLASH

OCCURS AT ADJACENT WALL, TYPICAL.

10. REFER TO SHEET 00.AI.002 FOR TYPICAL TILE PATTERN DETAIL.

11. REFER TO AI.10x SHEETS FOR WINDOW ELEVATION TAGS.

12. REFER TO MARKERBOARD SCHEDULE IN THE SPECIFICATIONS FOR

SIZES.

13. TURN COUNTERTOP DOWN AT CHANGE IN ELEVATION, TYPICAL.

14. LOCK LOCATIONS AT BASE AND UPPER CABINETS TO BE

COORDINATED

WITH RESIDENT ENGINEER.

15. GROMMET LOCATIONS TO BE COORDINATED WITH RESIDENT

ENGINEER.

16. REFER TO XX.AI.731 FOR BACKING PLATE SCHEDULE AND DETAIL.

INTERIOR ELEVATION NOTES

U4017 A5108 A5107 U4167

F3200

1' - 0"

A5075

A1066

A5080

U4148

VANITY LIGHT, SEE ELEC.

A6046

M0506 F3050

SEE FLR PLAN

4' - 9"

(A5080) 3' - 0"

3' 0"

1'

2' 3"

EQ 2' - 6" 2' - 0" EQ

EQ 2' - 6" 2' - 0" EQ

B15

W1 W1

B1

PLAM FACED

FASCIA PANEL

A5075

A5108

2' - 0" 2' - 6"

WF

1"

2' 3"

1'

3' 0"

BF

1"2' - 6"2' - 7 1/4"1' - 6"

BF

1"

M1801

A5108

A5080

A5075 W1 W1

B7 B15B1

PLAM FACED

FASCIA PANEL

(A5080) 2' - 0"

BF

EQ2' - 6"3' - 0"2' - 6"3' - 0"

BF

EQ

3' 0"

1'

2' 3" A5108

A5075

U4167 A5107

M1801

3' - 0"2' - 6"3' - 0"WF

3 1/2"

W1 W1 W1

B1 B1 B15

PLAM FACED

FASCIA PANEL

PLAM FACED

FASCIA PANEL

JOINT

SURGICAL LIGHT

CONTROLS

FURNISH AND

INSTALL LASER

PROTECTIVE SHADE

AT WINDOW

RE: SPECS

SOLID SURFACE

COUNTER

ON SSTL WALL

BRACKETS, ANGLES

& LEGS RE:9/AI.715-B

RETURN

GRILLE

RE: MECH

7' - 0"

F3200.A

A4015

F3050 A1014

U4210

14Hx14Dx4D ELEC

JUNCTION BOX WITH (4) 2

1/2" CONDUIT TO 14x14x4

JUNCTION BOX ABOVE OR

CEILING

OR INTEGRATION

SYSTEM

MONITOR

1' - 6"1' - 3"1' - 6"

EQEQ

INTEGRAL

BASE, TYP.

6" 6"

6" 1' 6"

AUTOMATIC OPERATOR

OVERRIDE KEY SWITCH

RE: DOOR HARDWARE

CODE BLUE

SOLID SURFACE

COUNTERTOP W/ 4"

BACKSPLASH ON SSTL

WALL BRACKETS,

ANGLES & LEGS RE:

9/XX.AI.715-B

SSST

SLOPED TOP

1' - 6 3/4"2' - 4 1/2"

SSA18A1130

5"5"

1' - 6"

1' - 6"

6" 1' 6"

INTEGRAL

BASE, TYP.

3' 6"

3' 8"

14Hx14Dx4D ELEC JUNCTION

BOX WITH (4) 2 1/2" CONDUIT

TO 14x14x4 JUNCTION BOX

ABOVE OR CEILING

1' - 3" 11' - 9" 3' - 0"

LINE ISOLATION

MONITORING

PANEL RE: ELEC

RETURN GRILLE

RE: MECH

RETURN GRILLE

RE: MECH

FEC

5' - 6" 1' - 3"1' - 3" 2' - 10" 4' - 8"

OR INTEGRATION

SYSTEM MONITOR

LASER OUTLET AT

24" AFF WITH

LOCAL RESET AT

54" AFF

RE: ELEC

X4122

7' - 0"

A5108 A5107

KE

YB

O

AR

D 3' 0"

ROOM LIGHT

SWITCHES RE: ELEC

AUTO OPERATOR

PUSH PLATE

INTEGRAL

BASE, TYP.

EQ EQ

RETURN GRILLE

RE: MECH

EQ EQ

1' - 7"2' - 0"1' - 6"9' - 0"

A5107A5108

ROOM LIGHT

SWITCHES

RE: ELEC

A1012

INTEGRAL

BASE, TYP.

F3050

M0506 ORIGINALLY ISSUED

WITH SHEET AI.X090, JSI

NO. 055

11 12 08 09 13

03040506

Drawing Number

Building Number

Project NumberProject Title

Location

Date Checked Drawn

Drawing Title

Approved: Project Director

Key PlanCONSULTANTS:

DateRevisions

1 2 3 4 5 6 7 8 9 10 11 12

D

C

B

A

554-501REPLACEMENT MEDICAL CENTER

FACILITY, EASTERN COLORADO

HEALTH CARE SYSTEM

AURORA, COLORADO

N

C O N

R

ES

D

AT

IB

S

IB

N

EN

C C

LC

C

BN

C

BC

C

BS

PS

N

PV

N

PV

S

13 14

1 2 3 4 5 6 7 8 9 10 11 12 13 14

E on e qu ar te r i nc h on e fo ot

OFFICE OF

CONSTRUCTION

AND FACILITIES

MANAGEMENT

ARCHITECT/ENGINEERS:Professional Seal

7/ /2 5:

:2

PM

C :\U se rs \C

AD

U se r 1 \D oc um en ts \A I-D

AT

_J es sy .M an ch a5

AV

.rv t

03.AI.567

LEVEL 3 INTERIOR ELEVATIONS -

SURGERY (PREOP/ PACU)

DIAGNOSTIC AND TREATMENT

08/31/2012

1/4" 1'-0"7 03-03-E5-03 - PACU TYP. - S

1/4" 1'-0"2

03-03-D6-01 - PREOP/ PACU -

N

1/4" 1'-0"3

03-03-D6-01 - PREOP/ PACU -

W

1/4" 1'-0"4

03-03-D6-01 - PREOP/ PACU -

S

1/4" 1'-0"11

03-03-D8-02 - NURSE STATION

- N

1/4" 1'-0"10

03-03-D8-02 - NURSE STATION

- E

1/4" 1'-0"12

03-03-D7-03 - PREOP/ PACU2

ISOLATION - N

1/4" 1'-0"13

03-03-D7-03 - PREOP/ PACU2

ISOLATION - W

1/4" 1'-0"14 03-03-B10-05 - CORRIDOR - N

1/4" 1'-0"6

03-03-E4-04 - NURSE STATION

- N WALL

1/4" 1'-0"8 03-03-E6-05 - CORRIDOR - N

1/4" 1'-0"15

03-03-F8-05 - PREOP/ PACU -

N

1/4" 1'-0"16 03-03-F8-05 - PREOP/ PACU - S

1/4" 1'-0"1 03-03-D5-01 - ANTEROOM - W

1/4" 1'-0"5 03-03-E4-03 - MED - N

1/4" 1'-0"9 03-03-F6-05 - MED - S

1/4" 1'-0"17 03-03-F2-01 - OR - N

1/4" 1'-0"18 03-03-F2-01 - OR - W

1/4" 1'-0"20 03-03-F2-01 - OR - E

1/4" 1'-0"19 03-03-F2-01 - OR - S

1/4" 1'-0"21

03-03-D7-04 - PREOP/PACU2 -

N

03.AI.563
Sheets: 03.AI.563 - LEVEL 3 INTERIOR ELEVATIONS - DIGESTIVE DISEASES
03.AI.565
Sheets: 03.AI.565 - LEVEL 3 INTERIOR ELEVATIONS - SURGERY
03.AI.567
Sheets: 03.AI.567 - LEVEL 3 INTERIOR ELEVATIONS - SURGERY (PREOP/ PACU)

File details come from the government source that posted it. Updated .