03 Equipment.pdf
PDF 7 MB Posted
- Solicitation number
- 36C25923R0033
About this file
This equipment plan document provides details for Level 3 of a replacement medical center facility. It includes floor plans for various areas labeled A through J, showing the location and types of medical equipment to be installed. Key equipment includes operating rooms, procedure rooms, diagnostic imaging systems, sterilization areas, and support spaces. The plans note design details deferred until final equipment selection and provide references to coordinate mounting locations.
The related federal contract opportunity is solicitation number 36C25923R0033 for project 554-23-103 to replace operating room booms at the Veterans Affairs Medical Center in eastern Colorado, with an agency listed as the VA's Veterans Integrated Service Network 19. The opportunity type is a solicitation and the description provided is for the referenced project to replace OR booms.
View the file
Other files
Show all 28
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
UP DN
PP
PP
P P
VSB
03-03-D2-04
CVOR
03-03-B2-06
DIGITAL QC
03-03-D2-01
SCRUB
03-03-E1-01
OFFICE
03-03-D1-02
OFFICE
03-03-D1-01
OFFICE
03-03-C1-02
STOR. ALCOVE
03-03-C2-01
PROCEDURE
03-03-C2-03
SYSTEM
COMPONENT
03-03-C2-02
GURNEY ALCOVE
03-03-B2-05
CONTROL
03-03-B2-04
SCRUB
03-03-B3-02
CLEAN CORE
03-03-B2-01
GURNEY ALCOVE
03-03-A2-02
CATH LAB
03-03-A1-T1
DATA / TELECOMM
03-03-B1-E1
ELEC
03-03-D10-H2
CHUTE
03-03-ST1
STAIR
03-03-PE5
ELEV
03-03-PE6
ELEV
03-03-E1-04
OFFICE
X4122
M1840
03-03-A2-01
SYSTEM
COMPONENT
03-03-D2-03
SYSTEM
COMPONENT
03-03-A1-01
EQUIP CLEAN UP
03-03-B2-03
CONTROL 2
03-03-B2-02
SCRUB/GOWN
03-03-D1-03
SECRETARY
03-03-B1-02
EQUIP STOR
M1810
03-03-D2-02
CVOR EQUIP
S E
E .Q
H .4
-B
SEE: 1/ 03.QH.403-D
S E
E .Q
H .4
-B
S E
E .Q
H .4
-D
S E
E .Q
H .4
-C
03-03-B1-01
EQUIP STOR
03-03-F1-02
CORRIDOR
A1012
M3070
M3072
03-03-C1-01
LINEN
B
C
D
E
A
A1012
U4167
A5080
A5075
F2020
F0205 F0205 F2000
A1011
M1801
F0275
F3025 F3050
R7000
K4665
F2025
F0210
F0210
F0210
F0210
F0210 F0210
F0210 F0210
F0210
M1801
M1801
F0210
F2000
F3200
F0515
F0210
F0210 F0210
F0210
F2000
A1011
F0275
M1801
F0275
F0275
F2000
F0420
A1015
M1801
U4167
A1066
F2020
A5075
U4167
A5160.B
X3150X3150
A1011
F2000
F3200.A
F3050
A1011
M1801
A1011
A5145A5145
F3200
A5075
M3070
X3150
F3200.A A1030
A1030
A1030
F2000
F3050
A1011
M1801
A1011
A5145A5145
A5145
F0110
A1030
F3050
A1011
M1801
F3200
A5145
U4008
M2100M2100M2100
M2100 M2100
M2100M2100
M2100
A1012
F3200.A
M1802
M1801
F0230
A1012
E0078 E0078
A5107
A5108
M8940
M2100
X4122
A5160.B
U4167
X4124
U4148
F2000
F0275
F0410 F0410
F0275
U4005
A5145
A5145
U4148
F0750
A5080
A5075
U4167
E0096
F3200
A5145
A5145
U4167
M2100
M2100
U1193
P6980.2
U4032 P6980.2
U4044
U1193U1193
U4032
F0230
F0230
F0230
F0230
U4047
U4053
U4024
F2000
E0912
E0912
E0912
E0912
E0912
E0912E0912E0912E0912E0912
E1500
E1500
E0921
M8080
U4213
U4167
F0275
F0275
F0275
X6175.1
U4053
U4024
U4167
U4259
U4259
U4259
A5145A5145
03-03-B1-03
CORRIDOR
03-03-D1-04
CIRC
03-03-C1-03
VEST
03-03-A3-05
CORRIDOR
U4165
F0115
F2000 M1801
A1011
E0078
F2000
M1801
A1011
E0078
F0275
F0275
A1012
M0507
03-03-C3-04
CORRIDOR
U4042
F3200
F2020
03-03-A3-02
INSTRUMENT RM
E0906.A
A5107
E0912
E0912
E0912
03.AI.454
03.AI.454
03.AI.455
A5108
03-03-B3-02
CLEAN CORE
U4217
A5075
F3200
U4148
03-03-E2-01
GURNEY ALCOVE
F3050
F0410
E1500
E0906.A
E0906.A
E0906.A
E0906.A
F3200
03-03-C1-03A
VEST
4' - 0"
TO STAND ISOCENTER
6' - 9 5/16"
T O
S T
A N
D I S
O C
E N
T E
R
/4
T O
T A
B L E
I S
O C
E N
T E
R
TO TABLE ISOCENTER
13' - 0"
X6190.A1X6190.1
3 U4135
U4005
X6175.9 X6190.A9
X6190.A7
X6190.A8
X6190.A3
X6190.A4
X6190.A5
X6190.A6
X6190.6
X6190.7
V V ITEM - VA SUPPLIED & INSTALLED
V C ITEM - VA SUPPLIED & CONTRACTOR
INSTALLED
C C ITEM - CONTRACTOR SUPPLIED &
INSTALLED
EQUIPMENT LEGEND
PROVIDE / INSTALL DESIGNATIONS AS SHOWN IN
LEGEND NO LONGER APPLY.
REFER TO SPECIFICATION SECTION 110601 FOR
PROVIDE / INSTALL VV, VC, CC DESIGNATIONS.
1. REFER TO INTERIOR ELEVATIONS FOR WALL MOUNTED EQUIPMENT
2. REFER TO SHEET 00.AI.002 FOR TYPICAL MOUNTING HEIGHTS LEGEND
3. REFER TO EQUIPMENT APPENDIX, SPECIFICATION 110601, FOR EQUIPMENT
INDICATED BY JSN NUMBER.
4. EQUIPMENT SHOWN IS GENERIC, OWNER TO PROVIDE FINAL EQUIPMENT
SELECTIONS FOR COORDINATION.
5. GENERAL CONTRACTOR TO VERIFY ROUGH-IN DIMENSIONS OF ALL
EQUIPMENT WITH MANUFACTURER AND OR WITH REUSED OR EXISTING
EQUIPMENT TO BE RELOCATED.
6. IN ALL ROOMS THAT CONTAIN DESIGN DEFERRED EQUIPMENT, THE
INFORMATION SHOWN ON THESE DOCUMENTS IS FOR PRICING ONLY.
CONSTRUCTION OF THESE SPACES AND PURCHASING OF MATERIALS,
INCLUDING ALL ARCHITECTURE, ASSOCIATED MECHANICAL, PLUMBING,
ELECTRICAL, IT, AND OTHER UTILITIES IS DEFERRED UNTIL THE EQUIPMENT
IS SELECTED AND THE FINAL CONSTRUCTION DOCUMENTS FOR THESE
SPACES ARE ISSUED.
7. ALL TV / MONITORS ARE SUPPORTED BY EITHER A WALL OR CEILING
MOUNTED BRACKET. REFER TO TELECOMMUNICATIONS DRAWINGS FOR
ADDITIONAL INFORMATION.
EQUIPMENT PLAN NOTES
11 12 08 09 13
03040506
Drawing Number
Building Number
Project NumberProject Title
Location
Date Checked Drawn
Drawing Title
Approved: Project Director
Key Plan
CONSULTANTS:
DateRevisions
1 2 3 4 5 6 7 8 9 10 11 12
D
C
B
A
554-501REPLACEMENT MEDICAL CENTER
FACILITY, EASTERN COLORADO
HEALTH CARE SYSTEM
AURORA, COLORADO
N
C O
N
R E
S
D A
T
I B
S
I B
N
E N
C
C L C
C B
N
C B
C
C B
S
P S
N
P V
N
P V
S
13 14
1 2 3 4 5 6 7 8 9 10 11 12 13 14
E
OFFICE OF
CONSTRUCTION
AND FACILITIES
MANAGEMENT
ARCHITECT/ENGINEERS:
H+L Architecture 1755 Blake Street, Suite 400 Denver, CO 80202
Skidmore, Owings & Merrill LLP 224 South Michigan Avenue Suite 1000 Chicago, IL 60604
Cator, Ruma & Associates 896 Tabor Street Lakewood, CO 80401
S. A. Miro, Inc.
4582 South Ulster Street Pkwy.
Suite 300 Denver, CO 80237
Professional Seal
/1
/2
:1
:3
P
M C
U s e rs
\k a n d e rs o n \D e s k to p
R e v it P ro je c ts
\V A
\A I-
D A
T .r v t
03.QH.403-A
LEVEL 3 EQUIPMENT PLAN - AREA A
DIAGNOSTIC AND TREATMENT
08/31/2012
1/4" = 1'-0"1
LEVEL 3 EQUIPMENT PLAN -
AREA A
A B
D C
F
G
J H
E
0' 2' 4' 8' 16'0' 2' 4' 8' 16'
NORTH
CDI No.12 08/31/2012
JSI No. 055 05/23/2013
JSI No. 058 07/22/2013
JSI No. 118 - POSTED SET 03/16/2015
Daniel.Erickson Callout RFI #9267: Per USACE contract, specs take precedence over drawings
Daniel.Erickson Callout
RFI #9267: DELTA 1
Daniel.Erickson Callout RFI #9267: VV Item. Provide backing if necessary.
Daniel.Erickson Callout RFI #9267: This is accepted.
Joshua.Sarahman Rectangle
Joshua.Sarahman Callout RFI #10114: Confirmed, it is acceptable to proceed with the modifications which will allow a successful installation for the stainless steel pedestals.
Joshua.Sarahman Rectangle
Joshua.Sarahman Callout RFI #10114: Confirmed, it is acceptable to proceed with the modifications which will allow a successful installation for the stainless steel pedestals.
UP DN
V
A
O
03-03-H2-06
HAC
03-03-H2-08
OR STOR
03-03-F2-01
OR
03-03-G1-02
EQUIP STOR
03-03-G2-01
INSTR PREP/STOR
03-03-E3-03
STERILE SUPPLY
STOR
03-03-G2-05
STERILE SUPPLY
STOR
03-03-D2-01
SCRUB
03-03-E2-02
GURNEY ALCOVE
03-03-G2-03
GURNEY ALCOVE
03-03-G2-02
SCRUB
03-03-E1-01
OFFICE
03-03-H1-01
SOILED CART
HOLD
03-03-H2-05
FROZEN SECT
03-03-H2-04
GAS CYL STOR
03-03-H2-03
STOR
03-03-H2-02
LINEN
03-03-H2-01
STOR. ALCOVE
03-03-F1-01
ANESTH.
WORK/STOR
03-03-F1-E2
ELEC
03-03-G1-T2
DATA / TELECOMM
03-03-SE10
ELEV
03-03-ST2
STAIR
03-03-SE9
ELEV
03-03-G2-04
OR
M0630
E0948
X4122
03-03-E1-02
OFFICE
03-03-E1-03
OFFICE
E0954
03-03-H2-07
OR STOR
03-03-E2-03
PUMP RM
03-03-G1-01
OR STOR
03-03-E2-04
CONTROL
03-03-E2-05
SCRUB
03-03-F2-02
STOR
R6010
U4044
M4810
A1012
A1012
S E
E .Q
H .4
-A S
E E
.Q
H .4
-A S
E E
.Q
H .4
-D
S E
E .Q
H .4
-C
SEE: 1/ 03.QH.403-C
E0912
M3150
M2100
F
H
J
F2000
F0275
F2000
F0275
A1011
M1801 F0275
M1801
A1011
F2000
F0275
F2000
A1011
M1801
M1801
F0275
A1011
F2000
E0921
E0912
F0230
F0230F0230
M1801 A1011 M1801
M1840
M1801
A1011
F2000
M2100
M2100
M2100
E0921
E0921
E0921
E0921
A1195
M2100
M2100
M2100
A5107
A5075
A5080
A1012
F3200.A
M1802
E0906.A
E0906.A
E0906.A
E0903.A
E0903.A
E0903.A
M1801
F0230
F2000
M1801
F0275F0275
A1011
M3110
F0230
M1801
A1011
F0230
M1801
A1011
M1825
F0230
M1801
F3200.A
E0948
F0515
F0515
A5080
A5075
F0500
F0275
M1801
A1011
M1801
F0275
A1011
M2100 M2100 M2100
U4044
E0903.A E0906.A
E0078
F0420
E0078
E0078
E0078
F3200.A
03-03-F2-03
CHARGE NURSE
A5145
A5145
A5145
A5145A5145A5145
A5075
A5080
U4167
U4167
M8950
M3175
M4255
X2105
A1011
M8080
U4032
U4032
A5075 A5080
F2020
F3200
F3050
M8800
M3150
M8800
U4161
E0906.A
M2100
A5075 A5080
A5107
A5108
F0530
M3072
F2020 U4167
U4119
U4119
U4119
U4119
F2000
U4150
F3200
M2600
U4167
E0120
E0120 F2000
M2100
M2100
03-03-H1-02
CORRIDOR
U4167
F2000
M1801
A1011
E0078
F0275
U4210
E1500
E1500
L1095
F2020
M4811
M4825
M4816
M4816
M8950
R6010.A
U4049
M2100 M2100 M2100 M2100 E0903.A
E1500
U4056U4221 U4221 U4221
U4221
F0535
F2000
M0630
F2000
A5107
M3150.B
F3200.A
E1500
M2025
L0100
U4195
M3080
E0921
M7665
E0903
A1012
U4056 U4056 U4162 U4162
U4160
R7050
M3150
U4160
U4056
M2100 M2100
F2025
A1012
M2115
M2650F0505
M2100
M2100
M2100
M2100
M2100
M2100
M2100
M2100
M2100
M2100
M2100
M2100
M2100M2100
M3080
03-03-F3-01
CLEAN CORE
G
FOR TYPICAL EQUIPMENT
IN 03-03-G2-04,
REFER TO 03-03-G3-02.
FOR TYPICAL BOOM MOUNT
LOCATIONS
IN 03-03-G2-04,
REFER TO 03-03-F3-04
U4217
FOR TYPICAL EQUIPMENT
IN 03-03-G2-04,
REFER TO 03-03-G3-02, ROTATED 180°
F0505
A5075
F3200
U4148
U1193U1193U1193U1193
E1500
U4504
U4504
U4506
U4505
U4503
/8
EQ 4' - 0" 2' - 0" 2' - 0" EQ
U4033.B
U4221
U4221
U4221
F0230
E0117
A1011
M1801
M1801
M1801
E0117 E0117
F0230 F0230
A1011
A1011
A1012
A5135 24"
PROVIDE WALL
BACKING FOR
FUTURE WALL
CABINETS
X6190.A1
X6190.A11
V V ITEM - VA SUPPLIED & INSTALLED
V C ITEM - VA SUPPLIED & CONTRACTOR
INSTALLED
C C ITEM - CONTRACTOR SUPPLIED &
INSTALLED
EQUIPMENT LEGEND
PROVIDE / INSTALL DESIGNATIONS AS SHOWN IN
LEGEND NO LONGER APPLY.
REFER TO SPECIFICATION SECTION 110601 FOR
PROVIDE / INSTALL VV, VC, CC DESIGNATIONS.
1. REFER TO INTERIOR ELEVATIONS FOR WALL MOUNTED EQUIPMENT
2. REFER TO SHEET 00.AI.002 FOR TYPICAL MOUNTING HEIGHTS LEGEND
3. REFER TO EQUIPMENT APPENDIX, SPECIFICATION 110601, FOR EQUIPMENT
INDICATED BY JSN NUMBER.
4. EQUIPMENT SHOWN IS GENERIC, OWNER TO PROVIDE FINAL EQUIPMENT
SELECTIONS FOR COORDINATION.
5. GENERAL CONTRACTOR TO VERIFY ROUGH-IN DIMENSIONS OF ALL
EQUIPMENT WITH MANUFACTURER AND OR WITH REUSED OR EXISTING
EQUIPMENT TO BE RELOCATED.
6. IN ALL ROOMS THAT CONTAIN DESIGN DEFERRED EQUIPMENT, THE
INFORMATION SHOWN ON THESE DOCUMENTS IS FOR PRICING ONLY.
CONSTRUCTION OF THESE SPACES AND PURCHASING OF MATERIALS,
INCLUDING ALL ARCHITECTURE, ASSOCIATED MECHANICAL, PLUMBING,
ELECTRICAL, IT, AND OTHER UTILITIES IS DEFERRED UNTIL THE EQUIPMENT
IS SELECTED AND THE FINAL CONSTRUCTION DOCUMENTS FOR THESE
SPACES ARE ISSUED.
7. ALL TV / MONITORS ARE SUPPORTED BY EITHER A WALL OR CEILING
MOUNTED BRACKET. REFER TO TELECOMMUNICATIONS DRAWINGS FOR
ADDITIONAL INFORMATION.
EQUIPMENT PLAN NOTES
11 12 08 09 13
03040506
Drawing Number
Building Number
Project NumberProject Title
Location
Date Checked Drawn
Drawing Title
Approved: Project Director
Key Plan
CONSULTANTS:
DateRevisions
1 2 3 4 5 6 7 8 9 10 11 12
D
C
B
A
554-501REPLACEMENT MEDICAL CENTER
FACILITY, EASTERN COLORADO
HEALTH CARE SYSTEM
AURORA, COLORADO
N
C O
N
R E
S
D A
T
I B
S
I B
N
E N
C
C L C
C B
N
C B
C
C B
S
P S
N
P V
N
P V
S
13 14
1 2 3 4 5 6 7 8 9 10 11 12 13 14
E
OFFICE OF
CONSTRUCTION
AND FACILITIES
MANAGEMENT
ARCHITECT/ENGINEERS:
H+L Architecture 1755 Blake Street, Suite 400 Denver, CO 80202
Skidmore, Owings & Merrill LLP 224 South Michigan Avenue Suite 1000 Chicago, IL 60604
Cator, Ruma & Associates 896 Tabor Street Lakewood, CO 80401
S. A. Miro, Inc.
4582 South Ulster Street Pkwy.
Suite 300 Denver, CO 80237
Professional Seal
/1
/2
:1
:4
P
M C
U s e rs
\k a n d e rs o n \D e s k to p
R e v it P ro je c ts
\V A
\A I-
D A
T .r v t
03.QH.403-B
LEVEL 3 EQUIPMENT PLAN - AREA B
DIAGNOSTIC AND TREATMENT
08/31/2012
1/4" = 1'-0"1
LEVEL 3 EQUIPMENT PLAN -
AREA B
A B
D C
F
G
J H
E
0' 2' 4' 8' 16'0' 2' 4' 8' 16'
NORTH
CDI No.12 08/31/2012
JSI No. 117 01/15/2015
JSI No. 118 - POSTED SET 03/16/2015
Daniel.Erickson Callout RFI #9267: Per USACE contract, specs take precedence over drawings
Daniel.Erickson Callout
RFI #9267: DELTA 1
Daniel.Erickson Callout RFI #9267: This is accepted.
sarah.hartsfield Cloud sarah.hartsfield Callout
RFI 9341
Delete M2025 Med Gas Storage Cages.
T D
A OV
03-03-H3-03
ORTHO STOR
03-03-E4-05
PACU
03-03-G3-02
OR
03-03-F3-04
OR
03-03-E3-02
OR
03-03-F3-03
STERILE SUPPLY
STOR
03-03-F3-02
CLEAN CART
RECEIV.
03-03-E3-03
STERILE SUPPLY
STOR
03-03-G3-01
STERILE SUPPLY
STOR
03-03-G4-01
GURNEY ALCOVE
03-03-G4-02
SCRUB
03-03-F4-02
GURNEY ALCOVE
03-03-F4-03
SCRUB
03-03-E4-02
SCRUB
03-03-H3-02
STAFF TLT
03-03-H3-04
STOR
03-03-H3-06
X-RAY EQUIP
STOR
03-03-H3-05
RECORDING
EQUIP
03-03-F4-05
SOILED UTIL
03-03-F4-04
PACU
03-03-E4-06
PACU
03-03-SE9
ELEV
X4122
M3070
M3072
M8920
M8810
M0630
M8800
M3175
F3200
M8810
F3200.AA4015
E0948
F0530
E0954
M3110
03-03-H4-01
OR EDUCATOR
03-03-H3-01
SUBSTERILE
03-03-F4-01A
OR STOR
03-03-F4-01B
STOR
03-03-H4-03
STOR
03-03-H4-02
RADIO FILM
PROCESS
Panel Line Isolation Monitoring
Panel Line Isolation Monitoring
A1130
A1012
S0125
F3050
A1012
A1012
A1012
S E
E .Q
H .4
-A
S E
E .Q
H .4
-B
S E
E .Q
H .4
-D
SEE: 1/ 03.QH.403-B
SEE: 1/ 03.QH.403-E
S E
E .Q
H .4
-D
E0954
E0954
M2100
F
H
J
4.6
E0948
M2100 M2100 M2100
U4167
S0125
U4167
A5200
A5090
A5145
A5080
A5075
F2000 A1011
M1801
F0275
F2000
F0275
A1011
M1801
A1011
M1801
F0275
A1011
F2000
F0300
M1801
M2100
M2100
A5160.A
M1801
M1801
M1832 A1014
M2100 M2100 M2100
M2100
M2100
M2100
M2100 M2100
M2100
M2100
M2100
M2100
M2100
M2100
M2100
M2100
M2100
A1012
E0903.A E0906.A
M8905M8905M8905
U4005
R6200
R6030
U4032U4032 U4032
U4032
U4032
A1012
E0906.A
03-03-F3-01
CLEAN CORE
R6030
M2100
A1012
F2000
A5075
A5080
A5108
A5107
A1012
M3072
M3070
F2020
U4167
A5075
U4148
A1066
F2000
E0948
M8825 M8825
X4780
X4780
X4890
E0078
E0120
E0120
F2000
F3200
U4167
U4167
F3200
X4122
U4056
U4045
U4027
U4259
U4259
U4210
03-03-F4-06
CORRIDOR
03-03-H3-07
CORRIDOR
U4167
M3110
A1012
U4033.A
M2100 M2100 M2100 M2100 E0903.A
E1500
A5107
F3200.A
A5107
M3150.B M3150.B
M3150.B
M3150
M3150
M3150
E0948 E0948
E1500 M3080
X4890 X4890 X4890
U4221
E0921
M7665
M7665
E0903
R6010.A
M2100
F3200.AM3080 M3080
M3080 E0906.A
E0912 E0903
E0906.A
A5107
A5107
A5108
A5108
F2020
E0939
F0230
F0230
F0355
M4815
M4255M4255
M4255
M9080 M4816
M5030
M7250
M7475
M7475
M7480
M8551
M8606
M8920
M8940
M8970
M8950
U4022
U4042
U4042
U4042 U4067
U4212
M8825
U4212
M3080
E0948 E0942
M8825 M8825
M9075 M9075 M9075
M5517 U4089
X4150
E0120
E0117
03-03-F3-01
CLEAN CORE
03.AI.455
G
FOR TYPICAL EQUIPMENT
IN 03-03-F3-04,
REFER TO 03-03-G3-02
FOR TYPICAL EQUIPMENT
IN 03-03-E3-02,
REFER TO 03-03-G3-02.
FOR TYPICAL BOOM MOUNT
LOCATIONS
IN 03-03-E3-02,
REFER TO 03-03-F3-04
E1500
EQ 2' - 0" 2' - 0" 4' - 0" EQ
U4035/M7480
U4035/M7480
U4033.A
E0903.A
E0903.A E0906.A
FOR TYPICAL BOOM MOUNT LOCATIONS
IN 03-03-G3-02,
REFER TO 03-03-F3-04
V V ITEM - VA SUPPLIED & INSTALLED
V C ITEM - VA SUPPLIED & CONTRACTOR
INSTALLED
C C ITEM - CONTRACTOR SUPPLIED &
INSTALLED
EQUIPMENT LEGEND
1. REFER TO INTERIOR ELEVATIONS FOR WALL MOUNTED EQUIPMENT
2. REFER TO SHEET 00.AI.002 FOR TYPICAL MOUNTING HEIGHTS LEGEND
3. REFER TO EQUIPMENT APPENDIX, SPECIFICATION 110601, FOR EQUIPMENT
INDICATED BY JSN NUMBER.
4. EQUIPMENT SHOWN IS GENERIC, OWNER TO PROVIDE FINAL EQUIPMENT
SELECTIONS FOR COORDINATION.
5. GENERAL CONTRACTOR TO VERIFY ROUGH-IN DIMENSIONS OF ALL
EQUIPMENT WITH MANUFACTURER AND OR WITH REUSED OR EXISTING
EQUIPMENT TO BE RELOCATED.
6. IN ALL ROOMS THAT CONTAIN DESIGN DEFERRED EQUIPMENT, THE
INFORMATION SHOWN ON THESE DOCUMENTS IS FOR PRICING ONLY.
CONSTRUCTION OF THESE SPACES AND PURCHASING OF MATERIALS,
INCLUDING ALL ARCHITECTURE, ASSOCIATED MECHANICAL, PLUMBING,
ELECTRICAL, IT, AND OTHER UTILITIES IS DEFERRED UNTIL THE EQUIPMENT
IS SELECTED AND THE FINAL CONSTRUCTION DOCUMENTS FOR THESE
SPACES ARE ISSUED.
EQUIPMENT PLAN NOTES
11 12 08 09 13
03040506
Drawing Number
Building Number
Project NumberProject Title
Location
Date Checked Drawn
Drawing Title
Approved: Project Director
Key Plan
CONSULTANTS:
DateRevisions
1 2 3 4 5 6 7 8 9 10 11 12
D
C
B
A
554-501REPLACEMENT MEDICAL CENTER
FACILITY, EASTERN COLORADO
HEALTH CARE SYSTEM
AURORA, COLORADO
N
C O
N
R E
S
D A
T
I B
S
I B
N
E N
C
C L C
C B
N
C B
C
C B
S
P S
N
P V
N
P V
S
13 14
1 2 3 4 5 6 7 8 9 10 11 12 13 14
E
OFFICE OF
CONSTRUCTION
AND FACILITIES
MANAGEMENT
ARCHITECT/ENGINEERS:
H+L Architecture 1755 Blake Street, Suite 400 Denver, CO 80202
Skidmore, Owings & Merrill LLP 224 South Michigan Avenue Suite 1000 Chicago, IL 60604
Cator, Ruma & Associates 896 Tabor Street Lakewood, CO 80401
S. A. Miro, Inc.
4582 South Ulster Street Pkwy.
Suite 300 Denver, CO 80237
Professional Seal
/1
/2
:2 :4
A
M C
U s e rs
\t m o re n o \D o c u m e n ts
\A I-
D A
T tm o re n o .r v t
03.QH.403-C
LEVEL 3 EQUIPMENT PLAN - AREA C
DIAGNOSTIC AND TREATMENT
08/31/2012
1/4" = 1'-0"1
LEVEL 3 EQUIPMENT PLAN -
AREA C
A B
D C
F
G
J H
E
0' 2' 4' 8' 16'0' 2' 4' 8' 16'
NORTH
CDI No.12 08/31/2012
JSI No. 117 01/15/2015
Marie.Funseth Text Box Refer to KT RFI 2275 and VA RFI 2005 for MEP, low voltage, and fire protection terminations for design deferred rooms until completion of final design.
Marie.Funseth Cloud
Marie.Funseth Arrow
Daniel.Erickson Callout RFI #9267: Per USACE contract, specs take precedence over drawings
Daniel.Erickson Callout
RFI #9267: DELTA 1
Daniel.Erickson Snapshot
Daniel.Erickson Snapshot
Daniel.Erickson
RFI #9267: This is accepted.
PP
03-03-D4-05
PACU
03-03-D4-06
PACU
03-03-D4-04
OR CONTROL
03-03-E3-01
STERILE SUPPLY
STOR
03-03-E4-01
GURNEY ALCOVE
03-03-D4-02
GURNEY ALCOVE
03-03-D4-03
SCRUB
03-03-D3-02
STERILE SUPPLY
STOR
03-03-D3-01
STERILE SUPPLY
STOR
03-03-C3-03
ANTEROOM
03-03-C3-02
ASEPTIC TRANS.
03-03-B4-04
STERILE SUPPLY
03-03-A3-02
INSTRUMENT RM
03-03-A3-03
EQUIP STOR
03-03-A4-01
SYSTEM
COMPONENT
03-03-A3-04
CATH LAB 1
03-03-B3-05
CONTROL 1
03-03-B4-02
GURNEY ALCOVE
03-03-C4-E3
ELEC
M1840
X4122
A1012
03-03-B4-01
SCRUB/GOWN
M3110
03-03-D3-04
EQUIP STOR
03-03-B3-06
VIEW
03-03-C4-01
STAFF TLT
03-03-D3-03
HAC
03-03-B3-03
OFFICE
03-03-B4-03
MED
03-03-C3-01
ANTEROOM
03-03-A3-01
PAT TLT
E0906.A
03-03-D3-05
OR
P6980.2
SEE: 1/ 03.QH.403-A S
E
E .Q
H .4
-A
S E
E .Q
H .4
-B S
E E
.Q
H .4
-C
SEE: 1/ 03.QH.403-E
S E
E .Q
H .4
-C
03-03-B3-01
OFFICE
03-03-B3-04
OFFICE
M3150
F2000
M2055
M2055
A5025
U4167
U4167
A5108
U4167
B
C
D
E
4.6
A
A1011
M1801
A5075
A5080R7200R7600R7200
A5080
A5075
F0280F0280
M1801
A1015
M1801
A1015
A5075
A5080
F0230
M1801
A5108
F0230
M1840
M1830
M1801
F3050
F3050
A1011
F0275
F3200
M1801
A1011 M1801
M3150.B
M3150.B
M3150.B
M3150.B A1012 A1012
A5200
A5080
A1066
A5075
A5145
F0275
F0275
F3200.A
M1801
M1801
F3200.A
A5145A5145
A1011
F3050
X3150
X3150
X3150
U4167
A5075
F2020
A5160.B A1066
F3050
U4167
F3200
A5107
F3050
M1801
A1011
M1801
F0280F0280
F2000
F3200.A
M1830
M1801
R6200.A
M3150
M3150.B
X6190.A3
A5108 A5200
A5075
A5080
A1066
U4167
A1011
A1011
E0120
E0120 F2000
X3150
A1011
E0078
F2000
F3200
F2000
X4122
A1011
A5145A5145
F2000
X4122
M2100
U4167
F3200
A5108A5107F2000
A5135
M2600
U4167
X4124
U4148
U4148 F2000
F0410
F0410
F0420
F0275
F0275
F0275
F0410 F0410
F0275
U4005
U4005
E0903.A
E0903.A
A1011
F0410
F0410U4042
E0906.A
A1012
A5075
A5080
A5107
A5108
F3200
U4167
U4148
U4032
U4032
E0921M2100
F0230
F0230
F0230
U4055
A1011
M1801
F0230
U4047
U4053
U4024
F0275
U4165
F0275
U4165
M1801
A1011
E0078
F2000
F0415
F0420
M2100 M2100 A5108
E1500
E1500 E1500
U1193U1193
F3200
U4032
M2100
M2100
M2100M2100
F0505
M2650
F0500
U4195
A5145
U4167
M2100
M2100
M2100
M2100
M2100
X4211
U4259
A5107
M2100
M2100
M2100
M2100
M2100
M2100
M2100
M2100
M1825
U4014
F2000
L2280
L2280
03-03-C3-04
CORRIDOR
03-03-B4-05
CORRIDOR
03-03-A3-05
CORRIDOR
X2105 M4811
U4042
E1500
A5107
M3150.B
M3150.B
E0948 E0948
E0912 E0903
E0906.A F3200.A
M3080M3080 E1500
M3110
E0906.AE0906.A
F0280
CLEAN
ROOM
PASS
THROUGH
WINDOW
CLEAN
ROOM
PASS
THROUGH
WINDOW
03-03-D4-01
VENDOR STOR
03-03-A3-02
INSTRUMENT RM
E0906.A
A5107
E0912
E0912
E0912
A5108
03-03-B3-02
CLEAN CORE
FOR TYPICAL EQUIPMENT
IN 03-03-E3-02,
REFER TO 03-03-G3-02.
FOR TYPICAL BOOM MOUNT
LOCATIONS
IN 03-03-E3-02,
REFER TO 03-03-F3-04
FOR TYPICAL EQUIPMENT
IN 03-03-D3-05,
REFER TO 03-03-G3-02.
FOR TYPICAL BOOM MOUNT
LOCATIONS
IN 03-03-D3-05,
REFER TO 03-03-F3-04
E1500
E0906.A
E0906.A
E0906.A
E0906.A
03.AI.454-A
5' - 0" 4' - 0"5' - 0"4' - 0"
9' - 0"
X6190.A4
X6190.A7
X6190.A8
M1801
E0117
F0230
PROVIDE WALL
BACKING FOR
FUTURE WALL
CABINETS
CU2
CU1
IS
LDC
LDC
IS
PU1
SC1
X6190.21
X6190.A7
X6190.A8
X6190.A3
X6190.A4
X6190.26
X6190.27
V V ITEM - VA SUPPLIED & INSTALLED
V C ITEM - VA SUPPLIED & CONTRACTOR
INSTALLED
C C ITEM - CONTRACTOR SUPPLIED &
INSTALLED
EQUIPMENT LEGEND
PROVIDE / INSTALL DESIGNATIONS AS SHOWN IN
LEGEND NO LONGER APPLY.
REFER TO SPECIFICATION SECTION 110601 FOR
PROVIDE / INSTALL VV, VC, CC DESIGNATIONS.
1. REFER TO INTERIOR ELEVATIONS FOR WALL MOUNTED EQUIPMENT
2. REFER TO SHEET 00.AI.002 FOR TYPICAL MOUNTING HEIGHTS LEGEND
3. REFER TO EQUIPMENT APPENDIX, SPECIFICATION 110601, FOR EQUIPMENT
INDICATED BY JSN NUMBER.
4. EQUIPMENT SHOWN IS GENERIC, OWNER TO PROVIDE FINAL EQUIPMENT
SELECTIONS FOR COORDINATION.
5. GENERAL CONTRACTOR TO VERIFY ROUGH-IN DIMENSIONS OF ALL
EQUIPMENT WITH MANUFACTURER AND OR WITH REUSED OR EXISTING
EQUIPMENT TO BE RELOCATED.
6. IN ALL ROOMS THAT CONTAIN DESIGN DEFERRED EQUIPMENT, THE
INFORMATION SHOWN ON THESE DOCUMENTS IS FOR PRICING ONLY.
CONSTRUCTION OF THESE SPACES AND PURCHASING OF MATERIALS,
INCLUDING ALL ARCHITECTURE, ASSOCIATED MECHANICAL, PLUMBING,
ELECTRICAL, IT, AND OTHER UTILITIES IS DEFERRED UNTIL THE EQUIPMENT
IS SELECTED AND THE FINAL CONSTRUCTION DOCUMENTS FOR THESE
SPACES ARE ISSUED.
7. ALL TV / MONITORS ARE SUPPORTED BY EITHER A WALL OR CEILING
MOUNTED BRACKET. REFER TO TELECOMMUNICATIONS DRAWINGS FOR
ADDITIONAL INFORMATION.
EQUIPMENT PLAN NOTES
11 12 08 09 13
03040506
Drawing Number
Building Number
Project NumberProject Title
Location
Date Checked Drawn
Drawing Title
Approved: Project Director
Key Plan
CONSULTANTS:
DateRevisions
1 2 3 4 5 6 7 8 9 10 11 12
D
C
B
A
554-501REPLACEMENT MEDICAL CENTER
FACILITY, EASTERN COLORADO
HEALTH CARE SYSTEM
AURORA, COLORADO
N
C O
N
R E
S
D A
T
I B
S
I B
N
E N
C
C L C
C B
N
C B
C
C B
S
P S
N
P V
N
P V
S
13 14
1 2 3 4 5 6 7 8 9 10 11 12 13 14
E
OFFICE OF
CONSTRUCTION
AND FACILITIES
MANAGEMENT
ARCHITECT/ENGINEERS:
H+L Architecture 1755 Blake Street, Suite 400 Denver, CO 80202
Skidmore, Owings & Merrill LLP 224 South Michigan Avenue Suite 1000 Chicago, IL 60604
Cator, Ruma & Associates 896 Tabor Street Lakewood, CO 80401
S. A. Miro, Inc.
4582 South Ulster Street Pkwy.
Suite 300 Denver, CO 80237
Professional Seal
/1
/2
:1
:0
P
M C
U s e rs
\k a n d e rs o n \D e s k to p
R e v it P ro je c ts
\V A
\A I-
D A
T .r v t
03.QH.403-D
LEVEL 3 EQUIPMENT PLAN - AREA D
DIAGNOSTIC AND TREATMENT
08/31/2012
1/4" = 1'-0"1
LEVEL 3 EQUIPMENT PLAN -
AREA D
A B
D C
F
G
J H
E
0' 2' 4' 8' 16'0' 2' 4' 8' 16'
NORTH
CDI No.12 08/31/2012
JSI No. 055 05/23/2013
JSI No. 117 01/15/2015
JSI No. 118 - POSTED SET 03/16/2015
Per KT RFI 5935/VA RFI 5189 there are no in-slab provisions in this area, topping slab can be placed.
Daniel.Erickson Callout RFI #9267: Per USACE contract, specs take precedence over drawings
Daniel.Erickson Callout
RFI #9267: DELTA 1
Daniel.Erickson Callout RFI #9267: This is accepted.
Joshua.Sarahman Rectangle
Joshua.Sarahman
RFI #10114: Confirmed, it is acceptable to proceed with the modifications which will allow a successful installation for the stainless steel pedestals.
DNUP
AOV
W A
G N
2O
O
O
A
V
CO2
V
OA
V CO2
AOV
W A
G N
2O
AOV
W A
G N
O
C B
V A O
V S
B
VSB
VSB
VSB
A
V V
V
V V
A
CO2
O
V V
A
V S
B
03-03-G10-03
CLEAN SCOPE
STOR
03-03-D9-05
PROCEDURE
03-03-E9-08
EGD/COLON
03-03-F9-03
EGD/COLON
03-03-F9-04
EGD/COLON
03-03-G10-02
SCOPE CLEAN UP
03-03-G10-04
X-RAY EQUIP
STOR
03-03-E10-01
DIGESTIVE
DISEASES CORE
03-03-F10-03
ERCP 1
03-03-E10-03
ERCP 2
03-03-F10-02
R/F CONTROL
03-03-F10-01
CLEAN UTIL
03-03-E10-02
BRONCHOSCOPY
03-03-G9-04
EGD/COLON
03-03-E10-06
CRASH CART
ALCOVE
03-03-D10-T4
DATA / TELECOMM
03-03-D10-E6
ELEC
03-03-ST5
STAIR
M2070
M8825
M3072
M3070
M3072 M3070
M3175
M3175
M4255
M8905
E0948
E0954
Locker, Supply, Endoscopy, Wall Mtd
Utility Boom, Med Gas, Power, Data w Display Monitor
M8810
M4255
F0340
M3072
Plugmold Electrical Outlets/ Data Drops for C-Arms and Portable X-
Ray Machines
Plugmold Electrical Outlets/ Data Drops for C-Arms and Portable X-
Ray Machines
03-03-G10-01
CLEAN SCOPE
STOR
M3110
M1801
Pneumatic Pass Through Window
(Activator at 48" AFF)
M1832
2x4 Room Lights, Dim Cans Med Gases: 0 - 1, V - 2
(Double qty if not on med gas boom)
UV Light at Patient Entry
UV Light at Staff Entry
03-03-E9-05
NURSE STATION
03-03-E9-06
MED PREP
03-03-E9-07
COPY/FAX
Electronic Patient Information Board
X4122
(4) Monitors on Arm(s)
X3150 U4022U4022
M8607.A
M8607.A
A1012
A1012
A1012
03-03-E10-04
CRASH CART
ALCOVE
U4044R6200
SEE: 1/ 03.QH.403-G
S E
E : 1
/ 0 3.
Q H
.4
-J S
E E
: 1 / 0
3.
Q
H .4
-J
M2100
03-03-E10-05
STOR
Equipment:
(3) C-Arms
(1) Portable X-Ray Machine
M3070
A1012
(20 Aprons)
Non-Pervious Linen Basket/Cart w/ Cover
M2100
Bronch. 18 Scope Cabinet
M3072
Integral BlindsIntegral Blinds
Auto Operator
Auto Operator
Auto Operator
M3150.B U4017
M7845
U4017
A5075
A5080 U4017A5108
U4150
E
F
H
RG.5
RG
RF.5
RF
RE.5
RD.5
R1
F3200.A
A5075 A5080
A5108
E0912
F0230
M1802
A5108 A5080
A5075
F3200.A
F2020
F2000
M3150.B
M3150.B
M3150.B
M2070
F2020
F3200.A
U4149 U4149
U4149U4149
U4167
U4148
A5160.C
U4148
U4148
U4148
A5160.C
A5075
A5080
A5108
F3200
A1012
A5075
A5080
S2627
S2627
U4167
F3200
M1802
M1801
A5080
A5075
S2627
M1801
M1802
M1801
A1012
M1840
M1830
F3050F0820
F0280F0280F0280
M1801
F3050
A1012
U4148
A5107
A5107
E0948
F0355
F0355
F0355
L0100
A5108
U4234
M9080
M8905
U4008
U4008
U4036
U4167
U4167
U4042U4042U4042
U4042
U4167
U4167
U4233
F3200.A
F3200.A
M3072
M3070
E0915
E0906
E0906
M1802 M1801
F0300F0340
U4148
A5108
A5080 A5075
A1012
M1801
M1801
F0340
U4035
E0120
X3150U4167U4014
M1801
A1012
M4655
M1801
E0948
F0355
M1832
U4008
M4255
A1012
U4233
U4042
U4167
U4148
M8770
A1011 A1011
A1011
F2000
F3200
M1620
F0420
A5108 A5080 A5075
A5107
F3200
A1011
U4167
A5107
M3070
M4255
U4014
U4233
U4148
F0355
M7845
A5107
A5108
A5160.D
U4150
A1012
A5108 A5107
X4780
A5075
A5080
A5108
A5107
F0530
U4205
M3070
F2020
M3072
F2000
A1011
M1801
F2000
A1011
M1801
F2000
A1011
M1801
U4005
E0078
M1825
U4008
U4008
U4220U4220
U4027
U4056
M3072
M3070
F3050
F0295
F0295F0295
F0295
M1820
U4148
F0465
F0280 M1801
F2000
F3050
U4148
U4042
U4053
U4053 U4053
U4024
U4024U4024
X4890
X4890
X4890M2055
D9058D9058
A5107
F0465 M1802
M1801
03-03-G9-07
CORRIDOR
F3200.A
M3070
U4167
A5080
A5075
F2000
U4167U4167
A5107
U4008
M8607.A
M3175
U4008
U4008
U4259
U4259
U4259
U4259
A1012
U4042
U4053 U4024
U4024
U4053
U4042
A5107
E0948
F0355 U4014
M3175
M4255
M7845
M8825
U4008
U4008
M1801U4008
U4024U4148
U4167
U4233
M7660
M7905
M1100
E0954
M8770
M7660
M7905
M1100
F0410
E0912 E0912
E1500
U4148
M3150
M3150
A5065.B
F0275
M1801
F3200
F0275
M1832
A5107
U4008
A5108
E0912
E0912
E0918
E0948
E1500
F2020
M8905
U4017 U4259
U4259
U4056
U4042
U4053
U4024
U4042
U4053
U4024
U4167
U4167
A1012
M7845
U4014 A5107
A5107
A5108
M4655
U4259
U4259
U4167
U4056
U4165
U4165
M8830
M8607
U4039
M1832
M8810
U4259
U4259
M7845
M8825
U4167
U4167 P6980.1
M3175
A5075
A5080
A5107 A5108
A5108
E1500
M4655
M0765
U4017
U4017
G
03-03-G9-03
HAC
03-03-G9-05
SOILED UTIL
U4148
A5107
U4167
4' - 0"
M7480
03-03-G9-08
UPS
UPS
UPC
X6185.A
X6185.A1
X6185.A2
X6185.A3
X6185.A4
X6185.A5
X6185.6
X6185.7
X6185.A10 X6185.A12
X6185.A11
X6185.A13
X6185.A14
X6185.A15 X6185.A16
M1801
03-03-E9-04
PROCEDURE
03-03-D9-04
PROCEDURE
X6185.A8
X6185.A9
F0275 F0275
U4033.A
V V ITEM - VA SUPPLIED & INSTALLED
V C ITEM - VA SUPPLIED & CONTRACTOR
INSTALLED
C C ITEM - CONTRACTOR SUPPLIED &
INSTALLED
EQUIPMENT LEGEND
1. REFER TO INTERIOR ELEVATIONS FOR WALL MOUNTED EQUIPMENT
2. REFER TO SHEET 00.AI.002 FOR TYPICAL MOUNTING HEIGHTS LEGEND
3. REFER TO EQUIPMENT APPENDIX, SPECIFICATION 110601, FOR EQUIPMENT
INDICATED BY JSN NUMBER.
4. EQUIPMENT SHOWN IS GENERIC, OWNER TO PROVIDE FINAL EQUIPMENT
SELECTIONS FOR COORDINATION.
5. GENERAL CONTRACTOR TO VERIFY ROUGH-IN DIMENSIONS OF ALL
EQUIPMENT WITH MANUFACTURER AND OR WITH REUSED OR EXISTING
EQUIPMENT TO BE RELOCATED.
6. IN ALL ROOMS THAT CONTAIN DESIGN DEFERRED EQUIPMENT, THE
INFORMATION SHOWN ON THESE DOCUMENTS IS FOR PRICING ONLY.
CONSTRUCTION OF THESE SPACES AND PURCHASING OF MATERIALS,
INCLUDING ALL ARCHITECTURE, ASSOCIATED MECHANICAL, PLUMBING,
ELECTRICAL, IT, AND OTHER UTILITIES IS DEFERRED UNTIL THE EQUIPMENT
IS SELECTED AND THE FINAL CONSTRUCTION DOCUMENTS FOR THESE
SPACES ARE ISSUED.
EQUIPMENT PLAN NOTES
11 12 08 09 13
03040506
Drawing Number
Building Number
Project NumberProject Title
Location
Date Checked Drawn
Drawing Title
Approved: Project Director
Key Plan
CONSULTANTS:
DateRevisions
1 2 3 4 5 6 7 8 9 10 11 12
D
C
B
A
554-501REPLACEMENT MEDICAL CENTER
FACILITY, EASTERN COLORADO
HEALTH CARE SYSTEM
AURORA, COLORADO
N
C O
N
R
E S
D A
T
IB
S
IB
N
E
N C
C
LC
C B
N
C
B C
C B
S
P
S N
P V
N
P
V S
13 14
1 2 3 4 5 6 7 8 9 10 11 12 13 14
E on e qu ar te r i nc h on e fo ot
OFFICE OF
CONSTRUCTION
AND FACILITIES
MANAGEMENT
ARCHITECT/ENGINEERS:
H+L Architecture 1755 Blake Street, Suite 400 Denver, CO 80202
Skidmore, Owings & Merrill LLP 224 South Michigan Avenue Suite 1000 Chicago, IL 60604
Cator, Ruma & Associates 896 Tabor Street Lakewood, CO 80401
S. A. Miro, Inc.
4582 South Ulster Street Pkwy.
Suite 300 Denver, CO 80237
Professional Seal
1/
/2
8:
:3
A
M C
:\U se rs \k an de rs on
\D es kt op
R ev it
P ro je ct s\ V
A \A
I- D
A T
_k an de rs on .r vt
03.QH.403-H
LEVEL 3 EQUIPMENT PLAN - AREA H
DIAGNOSTIC AND TREATMENT
08/31/2012
1/4" = 1'-0"1
LEVEL 3 EQUIPMENT PLAN -
AREA H
A B
D C
F
G
J H
E
0' 2' 4' 8' 16'0' 2' 4' 8' 16'
NORTH
CDI No.12 08/31/2012 JSI No. 117 01/15/2015
Marie.Funseth Cloud
Marie.Funseth Text Box Per KT RFI 2073 and VA RFI 1804, this note is deleted.
Marie.Funseth Arrow
Marie.Funseth Text Box Per KT RFI 3182/VA RFI 2778 the anesthesia boom in room 03-03-F10-03 is U4033.A.
tyler.turpin Triangle tyler.turpin Text Box tyler.turpin Text Box Per RFI 8320, the X3150 attaches to the wall and begins at the floor line and runs approximately 58" AFF. Treat the wall protection like a fire extinguisher cabinet or fire valve cabinets, and stop the wall guards 3" from the edge of the item. Do not provide wall guard between the two items, and only provide on either side if length is 2'-0" or greater. The sheet wall protection shall continue behind the X3150. Reference Wall Protection Legend Notes 5 and 6 on 00.AS.002.
tyler.turpin Triangle tyler.turpin Text Box tyler.turpin Cloud
Daniel.Erickson Callout RFI #9135: Piping a 1/2" lab air branch to each blowgun outlet up from the level 2 interstitial where 3/4" lab air piping was added to connect three fiber scope washers.
Daniel.Erickson Callout RFI #9267: Per USACE contract, specs take precedence over drawings
Daniel.Erickson Callout
RFI #9267: DELTA 1
Daniel.Erickson Snapshot
Daniel.Erickson Snapshot
Daniel.Erickson
RFI #9267: Provide backing for 03-03-E10-02 if necessary. Deleted monitor in 03-03-E10-01 is accepted.
FD
DNUP
FD
AOV
W A
G N
O
FD
FD
FD
03-03-B10-01
OFFICE 03-03-B10-02
OFFICE
03-03-A10-01
OFFICE
03-03-C9-03
STAFF LOUNGE
03-03-C10-02
MALE LOCKERS
03-03-C10-01
MALE
TLT/SHOWER
03-03-D9-04
PROCEDURE
03-03-B10-04
HALL
03-03-A10-03
OFFICE
03-03-A10-02
EQUIP SUPPORT
03-03-B10-03
OFFICE
03-03-D10-01
OR
COORDINATORS
03-03-ST3
STAIR
K4665
U4231
A1012
A1012
F3200
F3200
A1012
M1825 A1012
A1030
M3070
A1080
A1080
U4187
U4186
F0465
F3050
F3050
S E
E .Q
H .4
-F
S E
E .Q
H .4
-G S
E E
.Q
H .4
-H S
E E
.Q
H .4
-H S
E E
.Q
H .4
-H S
E E
.Q
H .4
-H
SEE: 1/ 03.QH.403-F
03-03-B10-05
CORRIDOR
03-03-C9-04
CORRIDOR
03-03-A9-05
CORRIDOR
K1552
K1552
K4665
03-03-D10-02
OR SCHEDULER
F3050
F2025
F2025
U4148
B
C
D
RC.5
RD
RC
RB.5
RB
RA
R1
A
F0205
F0205
F0205
F0280
M1801E0096
F0420
M1810
M1840
F0420
F0280
E0078
A1011
M1801
U4165
F0275
F2000
A1011
M1801
E0078
F0205 F0205 F0205F0205
U4186
U4187
U4148
F0410
F0275
M1801
A1011
F0225 F0225
F0225F0225
F0820
F0255
F0735
F0255
A5080 A5075
M2100
U4148
F2025
M2100
A5025
M3070U4148
A5075
A1066
A5080
A5080
U4305
R7250
U4148
F0225 F0225
F0225F0225
F0225 F0225 F0225 F0225 F0225 F0225
F0225 F0225 F0225 F0225 F0225 F0225
F0225 F0225 F0225 F0225 F0225 F0225
F0225 F0225 F0225 F0225 F0225F0225
F0225.A
F0225.A
F0225.A
F0225.A
F0225.A
F0225.A
F0225.A
A1012
M3070
A1080
F3050 U4148
M2100
M3070U4148
A5075
A1066
A5080
A5080
M1801
A1011
F0275
F2000
A6046
F2000
F3200
A5145
E0120
F0410
F0280
M1801
A1011
E0120
F2000
F3200
U4245
U4245
F2000
F2000
F0115 F0115
U4167
U4167
U4165
A5145A5145
F3200
A6046
F0110 U4165
F3200
A6046
F0115
E0078
F0275
F2000
A1015
M1801
E0078
A5145A5145
E0078
F0410
F0275
M1801
A1011
E0120
U4245
F2000
U4167 U4005
U4005
A5200
A5145A5145
A5145
U4167
U4167
A5075
A5080
F0795 F0795
F0795F0795A1015
U4167
U4167
U4167 U4070
U4070
F2000
A1011
M1801F0275
F2000
A1011
M1801F0275
F2000
A1011
M1801F0275
F3200
E0078
A5145
A5145
A5145
E0078
M1825
A5145
U4167
U4027
U4027
A6046
A5180
R7250
U4165 U4165
U4165 U4165
U4259U4259U4259
03-03-A9-02
OFFICE
03-03-B9-01
OFFICE
U4319U4319
U4305
A5145
A5200
U4259U4259U4259
U4366
A5165
03-03-D9-04
PROCEDURE
V V ITEM - VA SUPPLIED & INSTALLED
V C ITEM - VA SUPPLIED & CONTRACTOR
INSTALLED
C C ITEM - CONTRACTOR SUPPLIED &
INSTALLED
EQUIPMENT LEGEND
1. REFER TO INTERIOR ELEVATIONS FOR WALL MOUNTED EQUIPMENT
2. REFER TO SHEET 00.AI.002 FOR TYPICAL MOUNTING HEIGHTS LEGEND
3. REFER TO EQUIPMENT APPENDIX, SPECIFICATION 110601, FOR EQUIPMENT
INDICATED BY JSN NUMBER.
4. EQUIPMENT SHOWN IS GENERIC, OWNER TO PROVIDE FINAL EQUIPMENT
SELECTIONS FOR COORDINATION.
5. GENERAL CONTRACTOR TO VERIFY ROUGH-IN DIMENSIONS OF ALL
EQUIPMENT WITH MANUFACTURER AND OR WITH REUSED OR EXISTING
EQUIPMENT TO BE RELOCATED.
6. IN ALL ROOMS THAT CONTAIN DESIGN DEFERRED EQUIPMENT, THE
INFORMATION SHOWN ON THESE DOCUMENTS IS FOR PRICING ONLY.
CONSTRUCTION OF THESE SPACES AND PURCHASING OF MATERIALS,
INCLUDING ALL ARCHITECTURE, ASSOCIATED MECHANICAL, PLUMBING,
ELECTRICAL, IT, AND OTHER UTILITIES IS DEFERRED UNTIL THE EQUIPMENT
IS SELECTED AND THE FINAL CONSTRUCTION DOCUMENTS FOR THESE
SPACES ARE ISSUED.
EQUIPMENT PLAN NOTES
11 12 08 09 13
03040506
Drawing Number
Building Number
Project NumberProject Title
Location
Date Checked Drawn
Drawing Title
Approved: Project Director
Key Plan
CONSULTANTS:
DateRevisions
1 2 3 4 5 6 7 8 9 10 11 12
D
C
B
A
554-501REPLACEMENT MEDICAL CENTER
FACILITY, EASTERN COLORADO
HEALTH CARE SYSTEM
AURORA, COLORADO
N
C O
N
R E
S
D A
T
I B
S
I B
N
E N
C
C L C
C B
N
C B
C
C B
S
P S
N
P V
N
P V
S
13 14
1 2 3 4 5 6 7 8 9 10 11 12 13 14
E o n e q u a rt e r in c h o n e f o o t
OFFICE OF
CONSTRUCTION
AND FACILITIES
MANAGEMENT
ARCHITECT/ENGINEERS:
H+L Architecture 1755 Blake Street, Suite 400 Denver, CO 80202
Skidmore, Owings & Merrill LLP 224 South Michigan Avenue Suite 1000 Chicago, IL 60604
Cator, Ruma & Associates 896 Tabor Street Lakewood, CO 80401
S. A. Miro, Inc.
4582 South Ulster Street Pkwy.
Suite 300 Denver, CO 80237
Professional Seal
/1
/2
:2 :1
A
M C
U s e rs
\t m o re n o \D o c u m e n ts
\A I-
D A
T tm o re n o .r v t
03.QH.403-J
LEVEL 3 EQUIPMENT PLAN - AREA J
DIAGNOSTIC AND TREATMENT
08/31/2012
1/4" = 1'-0"1
LEVEL 3 EQUIPMENT PLAN -
AREA J
A B
D C
F
G
J H
E
0' 2' 4' 8' 16'0' 2' 4' 8' 16'
NORTH
CDI No.12 08/31/2012
JSI No. 117 01/15/2015
Marie.Funseth Polygon
Marie.Funseth Triangle
Marie.Funseth Text Box Per KT RFI 5103 (VAMC Req. 55) - Delete JSN A5090 - recessed sanitary napkin disposal
Marie.Funseth Callout
Daniel.Erickson Callout RFI #9267: Per USACE contract, specs take precedence over drawings
Daniel.Erickson Callout
RFI #9267: DELTA 1
Daniel.Erickson Snapshot
Daniel.Erickson Snapshot
Daniel.Erickson
RFI #9267: Abandon in place.
| 03.QH.403-A_JSI118.3 |
| 03.QH.403-B_JSI118.3 |
| 03.QH.403-C_JSI117 |
| 03.QH.403-D_JSI118.3 |
| 03.QH.403-H_JSI117 |
| 03.QH.403-J_JSI117 |
File details come from the government source that posted it. Updated .