Attch6_9 Plumbing Drawings Part 1.pdf
PDF 19 MB Posted
- Solicitation number
- 36C25920R0096
About this file
This document provides details on a federal contract opportunity for emergency department and support expansion at the Salt Lake City VA Medical Center. The contractor will be responsible for providing all materials and labor to build an 18,500 square foot addition and renovate 4,000 square feet for a new emergency department, police department, and support areas. The project budget is between $10-20 million. The solicitation number is 36C25920R0096 and the opportunity type is a pre-solicitation notice, with a request for proposal expected to be posted on July 27, 2020. The NAICS code is 236220 and the small business size standard is $39.5 million. This opportunity is 100% set aside for service-disabled veteran-owned small businesses. Offerors must be verified and listed in the Vendor Information Pages database to be considered for award. The contracting agency is the Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 19.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Amd0003_36C25920R0096 0003.docx | DOCX document | |
| Amd0003_attch2_36C25920R0096_1_updated per Amd0003.pdf | ||
| Amd0003_attch1_RFI_v3.pdf | ||
| Amd0002_attch2_HospitalLayout.pdf | ||
| Amd0002_36C25920R0096 0002.docx | DOCX document | |
| Amd0002_attch1_RFI_v2.pdf | ||
| Amd0001_36C25920R0096 0001.docx | DOCX document | |
| Amd0001_attch1_RFIs.pdf | ||
| Attch8_10 MechDrawings Part 1.pdf | ||
| Attch4_11 Elect Drawings Part 1.pdf | ||
| Attch7_ 9 Plumbing Drawings Part2.pdf | ||
| Attch2_6 Structural Drawings.pdf | ||
| Attch11_8 Arch Drawings Part 2.pdf | ||
| Attch10_7 Arch Drawings Part 1.pdf | ||
| 36C25920R0096_1.docx | DOCX document | |
| Attch13_Past Performance Questionnaire.docx | DOCX document | |
| Attch5_11 Elect Drawings Part 2.pdf | ||
| Attch1_3 General Drawings.pdf | ||
| Attch3_4 Civil Drawings.pdf | ||
| Attch9_8 Fire Protection Drawings.pdf | ||
| Attch12_5 Landscape Drawings.pdf | ||
| 36C25920R0096.docx | DOCX document |
Show all 22
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SYMBOL DESCRIPTION
MISC. SYMBOL LEGEND
PLUMBING SYMBOL LEGEND
SYMBOL DESCRIPTION
C.B. CATCH BASIN
M.H. MANHOLE
W.H. WALL HYDRANT
H.B. HOSE BIBB
CLEANOUT TO GRADE
FLOOR CLEANOUT
WALL CLEANOUT
1/2 GRATE
3/4 GRATE
FULL GRATE
SHEET
DETAIL INDICATOR: # INDICATES DETAIL
NUMBER, SHEET INDICATES DRAWING SHEET
WHERE DETAIL IS SHOWN.
SHEET
ELEVATION OR SECTION INDICATOR, EXTERIOR:
# INDICATES ELEVATION OR SECTION NUMBER,
SHEET INDICATES DRAWING SHEET WHERE
ELEVATION OR SECTION IS SHOWN.
ROOM OR SPACE NUMBER.100
KEYNOTE INDICATOR.1
REVISION INDICATOR.
EQUIPMENT INDICATOR.CU-1
PLUMBING FIXTURE INDICATOR.P-
DIFFUSER/GRILLE INDICATOR.
TYPE
CFM
SIZE
DIFFUSER/GRILLE INDICATOR.
TYPE
SIZE
BREAK, STRAIGHT
BREAK, ROUND.
MATCH LINE INDICATOR
HIDDEN FEATURES LINE: HIDDEN, THIN LINE.
CONTRACT LIMIT LINE: DASHDOT, WIDE LINE.
EXISTING
NEW CONNECTION POINT TO
IRRIGATION WATERIW
EVAC EVACUATION
CARBON DIOXIDECO2
NITROUS OXIDENO
MA MEDICAL AIR
N NITROGEN
O OXYGEN
COMPRESSED AIRA
VAC VACUUM
LPG PROPANE
G GAS
PURE WATER RETURNPWR
PURE WATER SUPPLYPWS
W WATER
SANITARY SEWERSS
EXISTING PIPE TO BE REMOVED(E)
(E) EXISTING PIPE
NON POTABLE WATER/
VENT THRU ROOFVTR
SRW SECONDARY RAINWATER
BELOW GRADE
SECONDARY RAINWATER
ABOVE GRADE
SRW
RW RAINWATER - BELOW GRADE
RAINWATER - ABOVE GRADERW
AW ACID WASTE - BELOW GRADE
160° HOT WATER RETURN160R
160° HOT WATER160
180° HOT WATER RETURN180R
DOMESTIC HOT WATER RECIRC (DHWR)
DOMESTIC HOT WATER (DHW)
DOMESTIC COLD WATER (DCW)
ACID WASTE - ABOVE GRADEAW
AV ACID VENT
VENT (V)
GREASE WASTE - BELOW GRADEGW
GREASE WASTE - ABOVE GRADEGW
SOIL, WASTE - BELOW GRADE (SW)
SOIL, WASTE - ABOVE GRADE (SW)
COMBINATION WASTE AND VENTCWV
180°F HOT WATER180
SD STORM DRAIN
PLUMBING PIPING LEGEND
SYMBOL DESCRIPTION
FP FIRE PROTECTION
A
B
C
D
E
F o n e e ig h t in c h o n e f o o t o n e q u a rt e r in c h o n e f o o t th re e e ig h th s i n c h o n e f o o t o n e h a lf i n c h o n e f o o t th re e q u a rt e rs i n c h o n e f o o t o n e i n c h o n e f o o t o n e a n d o n e h a lf i n c h e s o n e f o o t th re e i n c h e s o n e f o o t
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
F
IN
A L C
O N
S T
R U
C T
IO
N
D O
C U
M E
N T
S
CONSULTANTS: ARCHITECT / ENGINEERS: SEAL:
Revisions: Date:
Drawing Title
Approved: Project Director
Project Title
Location
Date Checked Drawn
Drawing Number
Building Number
Project Number
Dwg. _____ of _____197
URGENT CARE AND SUPPORT EXPANSION
VAMC SALT LAKE CITY, UTAH 84148
BOOGAARD GARTELL
660-332
PE001
PLUMBING COVER SHEET
08-11-2015
ABBREVIATIONS
NOTE: ALL ABBREVIATIONS MAY NOT BE USED.
DEFINITIONS
NOTE: ALL DEFINITIONS MAY NOT BE USED.
INDICATED: THE TERM "INDICATED" REFERS TO GRAPHIC REPRESENTATIONS,
NOTES, OR SCHEDULES ON THE DRAWINGS, OTHER PARAGRAPHS OR
SCHEDULES IN THE SPECIFICATIONS, AND SIMILAR REQUIREMENTS IN THE
CONTRACT DOCUMENTS. WHERE TERMS SUCH AS "SHOWN", "NOTED",
"SCHEDULED", AND "SPECIFIED" ARE USED, IT IS TO HELP THE READER LOCATE
THE REFERENCE, NO LIMITATION ON LOCATION IS INTENDED.
DIRECTED: TERMS SUCH AS "DIRECTED", "REQUESTED", AUTHORIZED",
"SELECTED", "APPROVED", "REQUIRED", AND "PERMITTED" MEAN "DIRECTED BY
THE ENGINEER", "REQUESTED BY THE ENGINEER", AND SIMILAR PHRASES.
APPROVED: THE TERM "APPROVED", WHERE USED IN CONJUNCTION WITH THE
ENGINEER'S ACTION ON THE CONTRACTOR'S SUBMITTALS, APPLICATIONS, AND
REQUESTS, IS LIMITED TO THE ENGINEER'S DUTIES AND RESPONSIBILITIES AS
STATED IN GENERAL AND SUPPLEMENTARY CONDITIONS.
FURNISH: THE TERM "FURNISH" IS USED TO MEAN "SUPPLY AND DELIVER TO THE
PROJECT SITE, READY FOR UNLOADING, UNPACKING, ASSEMBLY, INSTALLATION,
AND SIMILAR OPERATIONS."
INSTALL: THE TERM "INSTALL" IS USED TO DESCRIBE OPERATIONS AT PROJECT
SITE INCLUDING THE ACTUAL "UNLOADING, UNPACKING, ASSEMBLY, ERECTION,
PLACING, ANCHORING, APPLYING, WORKING TO DIMENSION, FINISHING, CURING,
PROTECTING, CLEANING, AND SIMILAR OPERATIONS."
PROVIDE: THE TERM "PROVIDE" MEANS "TO FURNISH AND INSTALL, COMPLETE
AND READY FOR THE INTENDED USE."
INSTALLER: AN "INSTALLER" IS THE CONTRACTOR OR AN ENTITY ENGAGED BY
THE CONTRACTOR, EITHER AS AN EMPLOYEE, SUBCONTRACTOR, OR SUB-
SUBCONTRACTOR, FOR PERFORMANCE OF A PARTICULAR CONSTRUCTION
ACTIVITY, INCLUDING INSTALLATION, ERECTION, APPLICATION, AND SIMILAR
OPERATIONS. INSTALLERS ARE REQUIRED TO BE EXPERIENCED IN THE
OPERATIONS THEY ARE ENGAGED TO PERFORM.
(E) EXISTING
(F) FUTURE
AD ACCESS DOOR
AIR COND AIR CONDITION(-ING,-ED)
APD AIR PRESSURE DROP
BD BALANCING DAMPER
BHP BRAKE HORSE POWER
BTU BRITISH THERMAL UNIT
BTUH BTU/HOUR
CFH CUBIC FEET PER HOUR
CFM CUBIC FEET PER MINUTE
CLG COOLING
COMP COMPONENT
COND CONDENS(-ER, -ING, -ATION)
CV CONTROL VALVE
DB DRY BULB TEMPERATURE
DCW DOMESTIC COLD WATER
DHW DOMESTIC HOT WATER
DHWR DOMESTIC HOT WATER RECIRC
DIA DIAMETER
DISCH DISCHARGE
DP DEPTH OR DEEP
EA EXHAUST AIR
EER ENERGY EFFICIENCY RATIO
EFF EFFICIENCY
EG ETHYLENE GLYCOL
ELEC ELECTRIC
ELEV ELEVATION
ENT ENTERING
EVAP EVAPORAT(-E, -ING, -ED, -OR)
EWT ENTERING WATER TEMPERATURE
EXT EXTERNAL
F FAHRENHEIT
FC FLEXIBLE CONNECT(-OR, -ION)
FD FIRE DAMPER
FLA FULL LOAD AMPS
FPI FINS PER INCH
FPM FEET PER MINUTE
FPS FEET PER SECOND
FSD FIRE SMOKE DAMPER
FT FEET
GAL GALLON(S)
GE GREASE EXHAUST
GPH GALLONS PER HOUR
GPM GALLONS PER MINUTE
HD HEAD
HG MERCURY
HP HORSEPOWER
HR HOUR
HT HEIGHT
HTG HEATING
HZ HERTZ (FREQUENCY)
ID INSIDE DIAMETER
IN INCH
KW KILOWATT
LAT LEAVING AIR TEMPERATURE
LBS POUNDS
LG LENGTH
LH LATENT HEAT
LRA LOCKED ROTOR AMPS
LVG LEAVING
LWT LEAVING WATER TEMPERATURE
MAX MAXIMUM
MBH THOUSAND BTU PER HOUR
MCA MINIMUM CIRCUIT AMPS
MFR MANUFACTUR(-ER, -ED)
MIN MINIMUM
N/A NOT APPLICABLE
NC NORMALLY CLOSED
NC NOISE CRITERIA
NIC NOT IN CONTRACT
NO NORMALLY OPEN
NPSH NET POSITIVE SUCTION HEAD
NTS NOT TO SCALE
OA OUTSIDE AIR
OD OUTSIDE DIAMETER
OZ OUNCE
PD PRESSURE DROP OR DIFFERENCE
PG PROPOLENE GLYCOL
PH PHASE
PPM PARTS PER MILLION
PRESS PRESSURE
PSF POUNDS PER SQUARE FOOT
PSI POUNDS PER SQUARE INCH
PSIA PSI ABSOLUTE
PSIG PSI GAUGE
R THERMAL RESISTANCE
RA RETURN AIR
RECIRC RECIRCULATE
REFR REFRIGERATION
REQD REQUIRED
RLA RATED LOAD AMPS
RPM REVOLUTIONS PER MINUTE
SA SUPPLY AIR
SC SHADING COEFFICIENT
SCFM STANDARD CUBIC FEET PER MINUTE
SCW SOFT COLD WATER
SF SAFETY FACTOR
SH SENSIBLE HEAT
SL SEA LEVEL
SP STATIC PRESSURE
SPEC(S) SPECIFICATION(S)
SQ SQUARE
STD STANDARD
SW SOIL, WASTE
TA(R) TRANSFER AIR (RETURN)
TA(S) TRANSFER AIR (SUPPLY)
TD TEMP. DROP OR DIFF.
TEMP TEMPERATURE
THERM THERMAL
TOT TOTAL
TSTAT THERMOSTAT
V VOLT
V VENT
VAC VACUUM
VAV VARIABLE AIR VOLUME
VEL VELOCITY TEMPERATURE
VEL VELOCITY
VENT VENT, VENTILATION
VERT VERTICAL
VFD VARIABLE FREQUENCY DRIVE
VOL VOLUME
WB WET BULB TEMP
WC WATER COLUMN
WG WATER GAUGE
WPD WATER PRESSURE DROP
WT WEIGHT
WTR WATER
YR YEAR
1 THE PLUMBING DRAWINGS SHOW THE GENERAL DESIGN, ARRANGEMENT AND
EXTENT OF THE PLUMBING SYSTEM. BECAUSE OF THE SMALL SCALE OF THE
DRAWINGS, THESE DRAWINGS DO NOT SHOW ALL OFFSETS, BENDS OR ELBOWS
NECESSARY FOR THE COMPLETE INSTALLATION IN THE SPACE PROVIDED.
CONTRACTOR SHALL MAKE SUCH SLIGHT ALTERATIONS AS MAY BE NECESSARY TO
MAKE THE SYSTEM COMPLETE AND OPERATIONAL IN ACCORDANCE WITH THE
DESIGN INTENT. MAJOR DEVIATIONS SUCH AS CHANGES IN COMPONENT SIZES,
WEIGHTS, QUANTITIES OR MATERIAL REQUIRE PRIOR APPROVAL BY THE DESIGN
ENGINEER.
2 THE DRAWINGS AND SPECIFICATIONS HAVE BEEN PREPARED TO SUPPLEMENT
EACH OTHER AND SHALL BE INTERPRETED AS AN INTEGRAL UNIT WITH THE ITEMS
SHOWN ON ONE AND NOT THE OTHER BEING FURNISHED AND INSTALLED AS
THOUGH SHOWN AND CALLED OUT IN BOTH.
3 THE ENTIRE PLUMBING INSTALLATION SHALL CONFORM TO THE REQUIREMENTS OF
THE MOST RECENTLY ADOPTED BUILDING CODES, MECHANICAL CODE, PLUMBING
CODE, ELECTRICAL CODE, AND ALL OTHER APPLICABLE CITY, COUNTY, STATE, AND
FEDERAL CODES AND REGULATIONS IN EFFECT.
4 THE ENTIRE PLUMBING INSTALLATION SHALL CONFORM TO ANY CODES, RULES,
REGULATIONS AND REQUIREMENTS OF THE BUILDING OWNER.
5 PRIOR TO FABRICATION AND INSTALLATION OF ANY PLUMBING COMPONENT THE
CONTRACTOR SHALL COORDINATE THE INSTALLATION OF ALL PLUMBING WORK
WITH ALL OTHER BUILDING TRADES, INCLUDING BUILDING TRADES HIRED DIRECTLY
BY THE OWNER. WHERE CONFLICTS MAY OCCUR, THEY SHALL BE RESOLVED PRIOR
TO INSTALLATION.
6 ALL PLUMBING INFORMATION IS NOT SHOWN ON THE PLUMBING DRAWINGS. THE
CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING ALL INFORMATION ON
ALL OTHER CONSTRUCTION DOCUMENTS.
7 . THE CONTRACTOR SHALL BE RESPONSIBLE TO REVIEW AND USE, WHERE
APPROPRIATE, ALL THE PLUMBING DETAILS SHOWN ON THE DRAWINGS. DETAILS
MAY OR MAY NOT BE CALLED OUT ON THE DRAWINGS WITH SYMBOLS OR KEYED
NOTES. ANY CHANGES RESULTING FROM FAILURE TO INSTALL THE PLUMBING
SYSTEM WITHOUT USING THE INCLUDED DETAILS SHALL BE THE RESPONSIBILITY
OF THE CONTRACTOR.
8 ANY PART OF THE PLUMBING INSTALLATION THAT FAILS, IS UNFIT, OR BECOMES
DAMAGED DURING CONSTRUCTION SHALL BE REPAIRED OR REPLACED BY THE
CONTRACTOR AT NO ADDITIONAL COST TO THE OWNER.
9 PROVIDE PROPER PROVISIONS FOR EXPANSION, CONTRACTION, OR MOVEMENT OF
ALL PIPING.
10 PROVIDE LARGE ENOUGH PIPE SLEEVES THROUGH WALL OR FLOOR TO ALLOW FOR
ANTICIPATED DIFFERENTIAL MOVEMENT.
11 ALL PIPING SHALL BE SUPPORT WITH CLEVIS HANGERS (MSS TYPE 1). PERFORATED
METAL STRAPS OR PLASTIC STRAPPING (PLUMBER TAPE) SHALL NOT BE USED TO
SUPPORT OR BRACE ANY PIPE.
12 PROVIDE PIPE HANGERS WITHIN 18-INCHES OF ALL CHANGES OF DIRECTION.
13 PROVIDE SWAY BRACING FOR ALL PIPING 4” AND LARGER AT ALL CHANGES IN
DIRECTION GREATER THAN 45-DEGREES.
14 ALL STEEL CLEVIS HANGERS USED TO SUPPORT COPPER PIPING SHALL BE COPPER
OR PLASTIC COATED.
15 COPPER PIPING SHALL NOT COME IN CONTACT WITH FIRE TREATED LUMBER.
PROVIDE ½” THICK SLIP-ON CLOSED CELL INSULATION WHERE COPPER PIPING IS
ADJACENT TO FIRE TREATED LUMBER. CLOSED CELL INSULATION SHALL EXTEND A
MINIMUM OF 1-1/2” PAST LUMBER.
16 ALL EXPOSED PIPING SHALL BE INSTALLED IN A NEATLY ARRANGED MANNER
PARALLEL TO THE BUILDING STRUCTURE.
17 ALL EXPOSED DOMESTIC WATER PIPE IN OCCUPIED SPACES SHALL BE POLISHED
CHROME PLATED.
18 ALL EXPOSED DRAINAGE PIPING IN OCCUPIED SPACES INCLUDING TRAPS UNDER
SINKS SHALL BE POLISHED CHROME PLATED.
19 DRAWINGS SHOW GENERAL ARRANGEMENT OF THE DRAIN WASTE AND VENT
SYSTEM WITH THE REQUIRED CLEANOUTS. CONTRACTOR SHALL PROVIDE ALL
ADDITIONAL CLEANOUTS AS REQUIRED BY THE PLUMBING CODE.
20 ALL SANITARY DRAINAGE SYSTEM PIPING 3” AND LARGER SHALL BE SLOPED IN
DIRECTION OF FLOW AT A MINIMUM OF 1/8” PER FOOT.
21 ALL SANITARY DRAINAGE SYSTEM PIPING SMALLER THAN 3” SHALL BE SLOPED IN
DIRECTION OF FLOW AT A MINIMUM OF 1/4” PER FOOT.
22 SLOPE VENT SYSTEM TOWARDS DRAINAGE SYSTEM.
23 SIMILAR EQUIPMENT SHALL BE OF THE SAME MANUFACTURER.
24 ALL EQUIPMENT SHALL PROVIDE THE SCHEDULED PERFORMANCE AT THE JOB SITE
ELEVATION.
25 FIXTURE AND EQUIPMENT MODEL NUMBERS SHOWN IN PLUMBING FIXTURE
SCHEDULE AND PLUMBING EQUIPMENT SCHEDULE ARE SHOWN TO ESTABLISH THE
TYPE OF PRODUCT THAT SHALL BE USED. THE SELECTED PRODUCT SHALL MEET
THE SCHEDULED PERFORMANCE DATA SHOWN ON THE SCHEDULE EVEN IF A
DIFFERENT MODEL IS SUPPLIED THAT IS DIFFERENT THAN THAT SCHEDULED.
26 ALL EQUIPMENT SHALL BE INSTALLED IN STRICT ACCORDANCE WITH THE
EQUIPMENT MANUFACTURER’S INSTALLATION INSTRUCTIONS. PROVIDE ALL
NECESSARY FITTINGS, TRANSITIONS, VALVES AND OTHER DEVICES AND
ACCESSORIES REQUIRED FOR A COMPLETE, WORKABLE INSTALLATION.
27 SEE “PLUMBING FIXTURE SCHEDULE” FOR INDIVIDUAL TRAPS, WASTE, VENT, AND
DOMESTIC WATER PIPING FOR INDIVIDUAL FIXTURES.
28 ALL PLUMBING EQUIPMENT SHALL BE LISTED AND LABELED BY AN APPROVED
TESTING AGENCY.
29 FIXTURES, EQUIPMENT AND PIPING INSTALLATION SHALL MEET NSF STANDARDS.
PLUMBING GENERAL NOTES
PLUMBING SHEET INDEX
PE001 PLUMBING COVER SHEET
PE501 PLUMBING DETAILS
PE601 PLUMBING SCHEDULES
PD101 LEVEL 1 PLUMBING PLAN - DEMOLITION
PL101 DOMESTIC WATER PIPING PLAN
PL101A LEVEL 1 PLUMBING PLAN - DW - AREA A
PL101B LEVEL 1 PLUMBING PLAN - DW - AREA B
PL101C LEVEL 1 PLUMBING PLAN - DW - AREA C
PL101D LEVEL 1 PLUMBING PLAN - DW - AREA D
PL102 ADMIN AREA PLUMBING PLANS
PL111 DRAIN WASTE AND VENT PLAN
PL111A LEVEL 1 PLUMBING PLAN - DWV - AREA A
PL111B LEVEL 1 PLUMBING PLAN - DWV - AREA B
PL111C LEVEL 1 PLUMBING PLAN - DWV - AREA C
PL111D LEVEL 1 PLUMBING PLAN - DWV - AREA D
PL112 ROOF PLUMBING PLAN
PL121 MEDICAL GAS PIPING PLAN
PL121A LEVEL 1 MEDICAL GAS PIPING PLAN - AREA A
PL121B LEVEL 1 MEDICAL GAS PIPING PLAN - AREA B
PL121C LEVEL 1 MEDICAL GAS PIPING PLAN - AREA C
PL121D LEVEL 1 MEDICAL GAS PIPING PLAN - AREA D
SOLENOID VALVE
S
BUTTERFLY VALVE
FLOAT AND THERMOSTATIC TRAP
ANCHOR
CAPPED PIPE
UNION
90 DEG TEE DOWN
90 DEG TEE UP
90 DEG ELBOW DOWN
90 DEG ELBOW UP
REFRIGERANT FILTER DRIER
REFRIGERANT STRAINER
REFRIGERANT SITE GLASS
REDUCER ECCENTRIC
REDUCER CONCENTRIC
VICTUALIC COUPLING
THERMOMETER
PRESSURE GAUGE
FLEXIBLE CONNECTION
GAUGE COCK
STRAINER
MANUAL AIR VENTMAV
GAS COCK
EXPANSION VALVE (REFRIG.)
FLOW SETTER
BALANCING OR PLUG COCK
VENTURI
ANGLE VALVE
PRESSURE REDUCING VALVE
CHAIN OPERATED GATE VALVE
RELIEF VALVE
BALL VALVE
GLOBE VALVE
AUTO 3-WAY VALVE
AUTO 2-WAY VALVE
CHECK VALVE
GATE VALVE
SHUT OFF VALVE
SYMBOL LEGEND
SYMBOL DESCRIPTION
R E FE RE N CE A ND LI NE S Y M B O L S
VALVES, METERS, AND GAUGES
MINIMUM PIPE INSULATION THICKNESS
FIELD OPERATING
TEMP RANGE (F)
INSULATION CONDUCTIVITY INSULATION THICKNESS (INCHES) BASED ON NOMINAL PIPE SIZE
CONDUCTIVITY
BTU*IN/(H*T^2*F)
MEAN RAITING
TEMPERATURE, F
LESS THAN 1"
DIA.
1"-1 1/2" DIA. 1 1/2"-4" DIA 4"-8" DIA. 8" DIA. AND ABOVE
>350 0.32-0.34 250 4.5 5.0 5.0 5.0 5.0
251-350 0.29-0.32 200 3.0 4.0 4.5 4.5 4.5
201-250 0.27-0.30 150 2.5 2.5 2.5 3.0 3.0
141-200 0.25-0.29 125 1.5 1.5 2.0 2.0 2.0
105-140 0.22-0.28 100 1.0 1.0 1.5 1.5 1.5
40-60 0.27-0.30 75 0.5 0.5 1.0 1.0 1.0
<40 0.20-0.26 50 0.5 1.0 1.0 1.0 1.5
1. THESE THICKNESSES ARE BASED ON ENERGY EFFICIENCY CONSIDERATIONS ONLY. ADDITIONAL INSULATION IS SOMETIMES REQUIRED FOR SAFETY ISSUES/SURFACE TEMPERATURE.
FOR PIPING SMALLER THAN 1 1/2" AND LOCATEDIN PARTITIONS WITH CONDITOINS SPACES, REDUCTION OF THESE THICKNESSES BY 1" SHALL BE PERMITTED, BUT NOT TO INSULATOIN THICKNESSES BELOW 1".
2. FOR DIRECT-BURIED HEATING AND HOT WATER SYSTEM PIPING, REDUCTION OF THESE THICKNESSES BY 1.5" SHALL BE PERMITTED, BUT NOT IN THICKNESSES BELOW 1".
3. FOR DIRECT-BURIED COOLING SYSTEM PIPING, INSULATION IS NOT REQUIRED.
4. THE TABLE IS BASED ON STEEL PIPE. NON-METALIC PIPES, SHEDULE 80 THICKNESS OR LESS SHALL USE TABLE VALUES. FOR OTHER NON-METALIC PIPES HAVING THERMAL RESISTANCE GREATER THAN THAT OF
THE STEEL PIPE, REDUCED INSULATION THICKNESSES ARE PERMITTED IF DOCUMENTATION IS PROVIDED SHOWING THAT THE PIPE WITH THE PROPOSED INSULATION HAS NO MORE HEAT TRANSFER PER FOOT THAN A STEEL PIPE OF THE SAME SIZE WITH THE INSULATION THICKNESS SHOWN IN THE TABLE.
8-11-15
WALL FLANGE
OUTLET DRAIN
EXTERIOR WALL
OVERFLOW DRAIN PIPE
SCREW TO WALL
FINISHED FLOOR
PVC CLEANOUT
PLUG AND FERRULE
WASTE PIPING
WYE
1/8" BEND
HEAVY DUTY ACCESS FRAME
AND COVER TOP OF COVER
SHALL BE FLUSH W/TOP OF
FLOOR.
TRAP GUARD
BY PROSET
OR EQUAL
INSULATION
PROTECTION
SHIELD
MSS SP-69 MSS SP-69
TYPE 1
PIPE TEMPERATURE
BELOW AMBIENT
INSULATED
TYPE 1
PIPE TEMPERATURE
ABOVE AMBIENT
INSULATED OR
UNINSULATED
CLEVIS HANGER
INSULATION
STEEL PIPE HANGERS FOR
COPPER PIPE SHALL BE
PLASTIC COATED.
NOTES:
STEEL PIPE HANGERS FOR
PLASTIC PIPE SHALL BE
PLASTIC COATED.
1.
2.
ELEVATION
A
ACOLLAR
2 LAYERS OF 5/8"
UL CLASSIFIED
GYPSUM WALLBOARD
2" COLLAR FILLED
W/METACAULK 880
PVC/CPVC PIPE
(DWV OR PRESSURE)
METACAULK 880
1/4" BEAD IN
ANNULUS
BUGLE-HEAD SCREW
SUMP RECEIVER
RIGID
STEEL DECK
UNDER DECK CLAMP
ALUMINUM DOME
STRAINER
FLASHING COLLAR
AND GRAVEL STOP
ROOFING MEMBRANE
ROOF STRUCTURE
ROOF DRAIN LEADER
INSULATION
A
B
C
D
E
F o n e e ig h t in c h o n e f o o t o n e q u a rt e r in c h o n e f o o t th re e e ig h th s i n c h o n e f o o t o n e h a lf i n c h o n e f o o t th re e q u a rt e rs i n c h o n e f o o t o n e i n c h o n e f o o t o n e a n d o n e h a lf i n c h e s o n e f o o t th re e i n c h e s o n e f o o t
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
F
IN
A L C
O N
S T
R U
C T
IO
N
D O
C U
M E
N T
S
CONSULTANTS: ARCHITECT / ENGINEERS: SEAL:
Revisions: Date:
Drawing Title
Approved: Project Director
Project Title
Location
Date Checked Drawn
Drawing Number
Building Number
Project Number
Dwg. _____ of _____197
URGENT CARE AND SUPPORT EXPANSION
VAMC SALT LAKE CITY, UTAH 84148
BOOGAARD GARTELL
660-332
PE501
PLUMBING DETAILS
08-11-2015
SCALE: NTS1
DOWNSPOUT NOZZLE DETAIL
SCALE: NTS2
FLOOR CLEANOUT1
SCALE: NTS3
FLOOR DRAIN1
SCALE: NTS4
PIPE HANGER
SCALE: NTS5
PIPE WALL SLEEVE
SCALE: NTS6
ROOF DRAIN
SCALE: NTS7
WASTE AND VENT ISOMETRIC
SCALE: NTS8
DOMESTIC WATER ISOMETRIC
A
B
C
D
E
F o n e e ig h t in c h o n e f o o t o n e q u a rt e r in c h o n e f o o t th re e e ig h th s i n c h o n e f o o t o n e h a lf i n c h o n e f o o t th re e q u a rt e rs i n c h o n e f o o t o n e i n c h o n e f o o t o n e a n d o n e h a lf i n c h e s o n e f o o t th re e i n c h e s o n e f o o t
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
F
IN
A L C
O N
S T
R U
C T
IO
N
D O
C U
M E
N T
S
CONSULTANTS: ARCHITECT / ENGINEERS: SEAL:
Revisions: Date:
Drawing Title
Approved: Project Director
Project Title
Location
Date Checked Drawn
Drawing Number
Building Number
Project Number
Dwg. _____ of _____197
URGENT CARE AND SUPPORT EXPANSION
VAMC SALT LAKE CITY, UTAH 84148
BOOGAARD GARTELL
660-332
PE601
PLUMBING SCHEDULES
08-11-2015
PLUMBING FIXTURE SCHEDULE
TAG DESCRIPTION WASTE TRAP VENT CW HW MAKE AND MODEL COMMENTS
DN-1 3" DOWN SPOUT ZURN Z199
DN-2 4" DOWN SPOUT ZURN Z199
DT-1 DECONTAMINATION TANK NORWESCO PROVIDE WITH ALARM AND VENT CONNECTION.
ESH-1 EMERGENCY SHOWER BRADLEY S19-310AC PROVIDE WITH T&P MIXING VALVE
FD-1 FLOOR DRAIN 3" 3" 1 1/2" 3/4" 3/4" ZURN Z-100 PROVIDE WITH TRAP GUARD
FD-2 CHANNEL DRAIN BLUCHER SHOWER CHANNEL WATERLINE 700 PROVIDE WITH TRAP GUARD
FS-1 FLOOR SINK ZURN Z-1900-K PROVIDE WITH TRAP GUARD
H-1 HYDRANT - LOCKABLE BOX AND KEYED HANDLE WOODFORD MODEL 68
HB-2 JR SMITH 5672 ANTISIPHON HOSE BIBB.
IMB-1 ICE MAKER BOX 0" 0" 1/2" 0" IPS MIB1HAAB
P-104 FLOOR MOUNTED WATER CLOSET WITH FLUSH
VALVE AND BED PAN WASHER
4" 4" 2" 1 1/4" 0" KOHLER K-4350 & K-10673 PROVIDE WITH BARIATRIC WALL CARRIER
P-401 WALL MOUNTED LAVATORY 2" 2" 1 1/4" 1/2" 1/2" KOHLER K-2210-0 & K-15182-XF-CP PROVIDE WITH T&P MIXING VALVE
P-413 EXAM SINK WITH FOOT PEDAL OPERATORS ELKAY DLR 191910, CHICAGO WITH 8"
GOOSENECK AND FLOOR MOUNTED PEDALS
PROVIDE WITH T&P MIXING VALVE
P-503 FLOOR MOUNTED CORNER MOP SINK 3" 3" 1 1/2" 3/4" 3/4" MUSTEE 62M, WITH 63.6001, 65.700, 65.600, 67.2424
P-505 SERVICE SINK AMERICAN STANDARD 9512.999.020, ZURN
Z6000AV-BWN
P-524 BREAK SINK ELKAY DLR 332210, CHICAGO 2304-ABCP
P-604 TWO STATION DRINKING FOUNTAIN 2" 2" 1 1/4" 1/4" 0" ELKAY LZWS-EDFPBM117K
P-701 SHOWER WITH HAND HELD SPRAYER KOHLER K-P15601-X4N & K-8515 & K-9514 &
K-9660
RD-1 ROOD DRAIN ZURN Z-100
SRD-1 SECONDARY ROOF DRAIN ZURN Z-100
MEDICAL ALARM PANEL SCHEULE
TAG
BOX
SERVED NOTES
LPA-1 ZVB-1 LOW PRESSURE ALARM
LPA-2 ZVB-2 LOW PRESSURE ALARM
LPA-3 ZVB-3 LOW PRESSURE ALARM
LPA-4 ZVB-4 LOW PRESSURE ALARM
LPA-5 ZVB-5 LOW PRESSURE ALARM
LPA-6 ZVB-6 LOW PRESSURE ALARM
MGMA MEDICAL GAS MASTER ALARM
MEDICAL GAS ZONE VALVE BOX
TAG
NUMBER OF OUTLETS SERVED
ROOMS SERVED NOTESOX AIR VAC SLIDE
ZVB-1 4 4 6 6 1G31 TRAUMA
ZVB-2 4 4 6 6 1G29 TRAUMA
ZVB-3 15 14 14 14 1G21 DECON, 1G05, 1G07, 1G09, 1G11, 1G13, 1G15, 1G17 EXAM
ZVB-4 7 7 7 7 1G59, 1G61 EXAM, 1G67, 1G69,1G71 FAST TRACK, 1G63 INTERNAL WAITING
ZVB-5 6 6 6 6 1G53, 1G55, 1G57 EXAM
ZVB-6 4 4 4 4 1G33A, 1G35 ISOLATION
DOMESTIC WATER RECIRCULATING PUMP SCHEDULE
SYMBOL GPM HEAD V-PH-Hz HP MAKE & MODEL NOTES
RP-1 3 15 120/1/60 1/6 B&G PR 3/4 1,2
MEDICAL GAS OUTLET SCHEDULE
TAG OX AIR VAC SLIDE ROOMS SERVED NOTES
MGO-1 1 0 0 0 DECON, AND INTERNAL WAITING
MGO-2 1 1 1 1 FAST TRACK
MGO-3 2 2 2 2 EXAM ROOMS
MGO-4 4 4 6 6 TRAUMA
MGO-5 1 1 1 0 OUTSIDE STUBS OUTDOOR LOCKABLE BOX
3"
4"
3"
3"
2"
3"
2"
3"
2"
2"
3"
3"
1-1/4"1-1/2" 1/2" 1/2"
1-1/2"3 1" 1/2"
1-1/4"1-1/2" 1/2" 1/2"
3/4"
1-1/2"3" 3/4" 3/4"
1-1/4"1-1/2" 3/4" 3/4"
ALL MEDICAL GAS OUTLETS TO BE REINFORCED
SCALE: NTS1
ROOF DRAINAGE ISOMETRIC
3/4"HOSE BIBB
V vent
V o
V
V
V
A
B
C
D
E
F o n e e ig h t in c h o n e f o o t o n e q u a rt e r in c h o n e f o o t th re e e ig h th s i n c h o n e f o o t o n e h a lf i n c h o n e f o o t th re e q u a rt e rs i n c h o n e f o o t o n e i n c h o n e f o o t o n e a n d o n e h a lf i n c h e s o n e f o o t th re e i n c h e s o n e f o o t
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
F
IN
A L C
O N
S T
R U
C T
IO
N
D O
C U
M E
N T
S
CONSULTANTS: ARCHITECT / ENGINEERS: SEAL:
Revisions: Date:
Drawing Title
Approved: Project Director
Project Title
Location
Date Checked Drawn
Drawing Number
Building Number
Project Number
Dwg. _____ of _____197
URGENT CARE AND SUPPORT EXPANSION
VAMC SALT LAKE CITY, UTAH 84148
BOOGAARD GARTELL
660-332
PD101
LEVEL 1 PLUMBING PLAN - DEMOLITION
08-11-2015
SCALE: 3/32" = 1'-0"F1
LEVEL 1 PLUMBING PLAN - DEMOLITION
NORTH
0 6' 12' 24' SCALE: NTS
KEY PLAN - URGENT CARE
1 REMOVE ALL ROOF DRAIN FIXTURES AND ASSOCIATED PIPING TO THIS
APPROXIMATE LOCATION.
2 REMOVE ALL PLUMBING FIXTURES IN PORTION OF BUILDING TO BE DEMOLISHED.
REMOVE ALL VENT PIPING. REMOVE WASTE PIPING BACK TO THIS APPROXIMATE
LOCATION.
3 REMOVE ALL ROOF DRAIN FIXTURES AND ASSOCIATED PIPING TO THIS
APPROXIMATE LOCATION AND CAP.
4 REMOVE ALL PLUMBING FIXTURES IN PORTION OF BUILDING TO BE DEMOLISHED.
REMOVE ALL DOMESTIC WATER PIPING BACK TO THIS APPROXIMATE LOCATION.
SHEET KEYNOTES
P F
P F
STAFF WC/SHOWER
1G47A
STAFF LOUNGE
1G27
EQUIPMENT
1G25
DISASTER/DECON SUPPLY
1G23
DECON ROOM
1G21
EMS SUPPLY
1G19A
STAT LAB
1G00GB
TRAUMA ROOM
1G29
TRAUMA ROOM
1G31
ISOLATION EXAM
1G33A
ISOLATION EXAM
1G35
EXAM
1G17
EXAM
1G15
EXAM
1G13
EXAM
1G11
EXAM
1G09
EXAM
1G07
BARIATRIC EXAM
1G08
EXAM
1G10
EXAM
1G12
MEDS
1G22A
TOILET
1G04
TOILET
1G06
CLEAN SUPPLY
1G22D
MH CLINICAL OFFICE
1G24
HALL
1G00C FAST TRACK/EXAM
1G71
FAST TRACK/EXAM
1G69
FAST TRACK/EXAM
1G67
TOILET
1G65
VIS. TOILET
1G79
VIS. TOILET
1G77
EXAM
1G61
EXAM
1G59
EXAM
1G57
EXAM
1G53
SOILED UTILITY
1G49
IT ROOM
1B47
ARMORY
1B45B
OFFICER
1B45.01
CHIEF
1B45E
OFFICER
1B45.07
OFFICER
1B45.05
OFFICER
1B45.04
STORAGE
1B45F
NURSE SUPER.
1G37
ER DIRECTOR
1G39
ON-CALL
1G41
SHARED CONFERENCE
1G43
ALCOVE
1G00GA
REC / ENROLLMENT / POLICE
1G73
WAITING ROOM
1G01
VESTIBULE
1G00A
PHYS. WORK
1G16
NURSE WORK S
1G18
STORAGE
1B41
VESTIBULE
1G00DA
BIOMED
1G87
STAFF WC
1G47
SHARED EDUCATION
1G45
EVIDENCE
1B45G
1G00HA
CHARTING
1G00FA
GENERATOR
1G81
HALL
1B00G
X-RAY
1G20
ANTE ROOM
1G33
SECLUSION
1G51
EXAM
1G55
UM WK.
1G00E.02
PHARM. WK.
1G00E.01
BREAK ROOM
1B45A
OFFICER
1B45.02
OFFICER
1B45.03
MENS WC
1B45D
WOMENS WC
1B45C
ELECTRICAL ROOM
1G85
EM ELEC. ROOM
1G83
OB toilet
1G05A
DISPATCH
1B45H
VESTIBULE
1B43
PSA
1B43A.01
HOLD
1B43AA
INTERVIEW
1B43B
CLEAN LINEN
1G22B
EVS
1G22C
NURSE WORK/ FAST TRACK
1G02
INTERNAL WAITING
1G63
REC / ENROLLMENT / POLICE
1G73
OB/GYN Exam
1G05
FAMILY CONSULT
1G03
TRIAGE
1G00BA
ENROLLMENT
1G75
NURSE WORK N
1G14
ALCOVE
1G00GA
HALL
1G00F
HALL
1G00E
HALL
1G00E
HALL
1G00F
CORRIDOR
1G00O
HALL
1G00K
R6
R6
R7
R7
1.3
A
H
B
C
D
E.1
E.1
2.5
M
K
J
RG
RD
RB
EV
EX
EW
R4
R3
R2
EU
E18
E21 E23 E26
RC
G
D.2
2.9
H.8
L
2.1 2.3 2.7
R5
E24
D.8
E33B
E26A
RE
O
RA
RF
RF
F.5
RH
E
E
C.9
C.9
E.5
F F.4
E.7
R1
E.4
/4
"ø D
H W
R
/2 "ø
D C
W
/2 "ø
D H
W
RCP-1
MATCHLINE AREA B
MATCHLINE AREA D
MATCHLINE AREA C
MATCHLINE AREA D
M A
T C
H L
IN
E A
R E
A C
M A
T C
H L
IN
E A
R E
A B
MATCHLINE AREA A
MATCHLINE AREA C
MATCHLINE AREA A
MATCHLINE AREA B
A
B
C
D
E
F o n e e ig h t in c h o n e f o o t o n e q u a rt e r in c h o n e f o o t th re e e ig h th s i n c h o n e f o o t o n e h a lf i n c h o n e f o o t th re e q u a rt e rs i n c h o n e f o o t o n e i n c h o n e f o o t o n e a n d o n e h a lf i n c h e s o n e f o o t th re e i n c h e s o n e f o o t
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
F
IN
A L C
O N
S T
R U
C T
IO
N
D O
C U
M E
N T
S
CONSULTANTS: ARCHITECT / ENGINEERS: SEAL:
Revisions: Date:
Drawing Title
Approved: Project Director
Project Title
Location
Date Checked Drawn
Drawing Number
Building Number
Project Number
Dwg. _____ of _____197
URGENT CARE AND SUPPORT EXPANSION
VAMC SALT LAKE CITY, UTAH 84148
BOOGAARD GARTELL
660-332
PL101
DOMESTIC WATER PIPING PLAN
08-11-2015
SCALE: 3/32" = 1'-0"F3
OVERALL DOMESTIC WATER PLUMBING PLAN
NORTH
0 6' 12' 24' SCALE: NTS
KEY PLAN - URGENT CARE
SHEET KEYNOTES
1 CONNECT TO EXISTING DOMESTIC WATER PIPING IN "L" SHAPED ROOM NORTH
OF STAIRS ADJACENT TO ELEVATORS.
SCALE: 1/32" = 1'-0"F1
DOMESTIC WATER TIE IN LOCATION
1.3 H
E.1
E.1
2.5
M
K
J
EV
EX
EW
EU
E18 E21 E23 E26
G
2.9
H.8
L
2.1 2.3 2.7E24
D.8
E26A
F.5
E
E E.5
P-104
P-104
P-104
P-401
P-401
P-413
P-401P-505
P-401
P-701RCP-1
P-701
P-413
/4
"ø D
H W
R
2 1/2"ø DCW
1/2"ø DHWR 1 1/4"ø DHW
1 1/4"ø DHW
1/2"ø DHWR
2 1/2"ø DCW
2 1/2"ø D C W
1"ø D H W 1/2"ø D
H W
R 1/ 2" ø D H W
1/ 2" ø D C W
1/
4" ø
D C W
1/ 2" ø D H W
1/
4" ø
D C W
1"ø D H W
1/2"ø D H W
R
2 1/2"ø DCW
/4
"ø D
H W
R
/4 "ø
D H
W
/4
"ø D
H W 3/4"ø D
C W
1"ø DHW 1/2"ø DHWR
3/ 4" ø D C W
1/
2" ø
D C W1/
2" ø D
H W
R
1" ø D
H W
3/4"ø D H W
1 1/4"ø D C W
1/2"ø D H W
1 1/4"ø D C W
/4
"ø D
C W
1 1/4"ø D C W
/4
"ø D
H W
1/2"ø D C W
1/
2" ø
D C W3/
4" ø D
H W
1/ 2" ø D H W
R
ISOLATION EXAM
1G35
CORRIDOR
1G00O
CHARTING
1G00FA
NURSE SUPER.
1G37
ER DIRECTOR
1G39
HALL
1B00E
ON-CALL
1G41
HALL
1G00J
DISPATCH
1B45H
HALL
1B45
IT ROOM
1B47
ARMORY
1B45B
BREAK ROOM
1B45A
WOMENS WC
1B45C
MENS WC
1B45D
OFFICER
1B45.01
OFFICER
1B45.02
OFFICER
1B45.03
Hall
1B43A
OFFICER
1B45.05
OFFICER
1B45.04
EVIDENCE
1B45G
STORAGE
1B45F
PSA
1B43A.01
VESTIBULE
1B43
Hall
1B43A
OFFICER
1B45.06
CHIEF
1B45E
OFFICER
1B45.07
HOLD
1B43AA
INTERVIEW
1B43B
STORAGE
1B41
SHARED CONFERENCE
1G43
HALL
1B00G
OFFICE
1B22
BIOMED
1G87
ELECTRICAL ROOM
1G85
SOILED UTILITY
1G49
TOILET
1G33B
SHARED EDUCATION
1G45
1G00HA
HALL
1G00P
H-1
3/ 4" ø D C W
1/2"ø DCW
MATCHLINE AREA A
MATCHLINE AREA C
MATCHLINE AREA A
MATCHLINE AREA B
/2
"ø D
H W
R
1"ø DHW 1 1/2"ø DCW
A
B C
D
DEDUCT ALTERNATE F: SHELL POLICE AREA. COMPLETE THE EXTERIOR WALLS
WITH INSULATION AND VAPOR BARRIER (BUT NO INTERIOR GYPSUM BOARD)
AND ELECTRICAL ROUGH-IN. OTHERWISE SHELL THE AREA. DEMOLISH ALL
ARCHITECTURAL, MECHANICAL, ELECTRICAL AND PLUMBING FEATURES WITH IN
THE SHELL AS IDENTIFIED IN THE BASE SCOPE OF WORK. DO NOT COMPLETE
ANY OF THE INTERIOR WALLS, DOORS, FINISHES MECHANICAL, ELECTRICAL,
PLUMBING AND FIRE WORK. CONSTRUCT DOOR 1B43 FOR ACCESS TO SHELLED
AREA. SEE AE001 FOR FURTHER INFORMATION.
DEDUCT ALTERNATE G: DEDUCT NEW CONSTRUCTION IN POLICE AREA INCLUDING
NO DEMOLITION OF CURTAIN WALL ENCLOSED EXTRASTITIAL SPACE, NO
MODIFICATIONS TO BRIDGE ABOVE AND ALL ASSOCIATED CIVIL, STRUCTURAL,
ARCHITECTURAL, MECHANICAL, ELECTRICAL, PLUMBING AND FIRE WORK.
DEMOLITION OF EXISTING INTERIOR SPACE THAT WOULD COMPRISE NEW POLICE
AREA IS STILL REQUIRED, AND IS TO REMAIN AS IS, AND NOT AFFECTED BY THIS
DEDUCTIVE ALTERNATE. EXTEND NEW EXTERIOR WALL TO FACE OF EXISTING
CURTAIN WALL AND MODIFY STRUCTURE AND ROOF ABOVE. SEE AE001 FOR
FURTHER INFORMATION.
DEDUCT ALTERNATE H: DEDUCT NEW CONSTRUCTION IN POLICE AREA INCLUDING
NO DEMOLITION OF CURTAIN WALL ENCLOSED EXTRASTITIAL SPACE, NO
MODIFICATIONS TO BRIDGE ABOVE AND ALL ASSOCIATED CIVIL, STRUCTURAL,
ARCHITECTURAL, MECHANICAL, ELECTRICAL, PLUMBING AND FIRE WORK. DO NOT
DEMOLISH ANY EXISTING INTERIOR. EXTEND NEW EXTERIOR WALL TO FACE OF
EXISTING CURTAIN WALL AND MODIFY STRUCTURE AND ROOF ABOVE. SEE AE001
FOR FURTHER INFORMATION.
A
B
C
D
E
F o n e e ig h t in c h o n e f o o t o n e q u a rt e r in c h o n e f o o t th re e e ig h th s i n c h o n e f o o t o n e h a lf i n c h o n e f o o t th re e q u a rt e rs i n c h o n e f o o t o n e i n c h o n e f o o t o n e a n d o n e h a lf i n c h e s o n e f o o t th re e i n c h e s o n e f o o t
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
F
IN
A L C
O N
S T
R U
C T
IO
N
D O
C U
M E
N T
S
CONSULTANTS: ARCHITECT / ENGINEERS: SEAL:
Revisions: Date:
Drawing Title
Approved: Project Director
Project Title
Location
Date Checked Drawn
Drawing Number
Building Number
Project Number
Dwg. _____ of _____197
URGENT CARE AND SUPPORT EXPANSION
VAMC SALT LAKE CITY, UTAH 84148
BOOGAARD GARTELL
660-332
PL101A
LEVEL 1 PLUMBING PLAN - DW - AREA A
08-11-2015
SCALE: 3/16" = 1'-0"F3
DOMESTIC WATER PLAN - AREA A
NORTH
0 2' 4' 8'
SCALE: NTS
KEY PLAN - AREA A
1 PROVIDE 1/2" WATER LINE TO HUMIDIFIER ABOVE. PROVIDE WITH SHUTOFF
VALVE IN ACCESSIBLE LOCATION.
2 SEE PL101C FOR CONTINUATION.
3 3/4" COLD WATER THREADED CONNECTION TO PULP DISPOSAL UNIT.
COORDINATE EXACT LOCATION WITH OWNER. PULP DISPOSAL IS OWNER
PROVIDED.
4 SEE PL101B FOR CONTINUATION
5 SEE PL101B FOR CONTINUATION.
6 CONNECT TO EXISTING DOMESTIC WATER PIPING IN "L" SHAPED ROOM NORTH
OF STAIRS ADJACENT TO ELEVATORS.
1.3
A
H
B
C
D
E.1
E.1
2.5
EXEX
R3R2
E18 E21 E23 E26
RC
RC
D.2
2.1 2.3
E24
E24
D.8
E26A
O
RA
RA RF
RF
E
E
C.9
C.9
E.5
R1
E.4
P-524
P-104
P-401
P-401
P-104
P-413
P-413
P-413
P-413
P-413
P-413
P-413
P-701P-701
ESH-1
P-413
P-413
P-413
P-413
P-401
P-104
P-401
P-104
P-413
P-413
P-413
P-413
P-505
P-401
P-413
3/ 4" ø D C W
3/ 4" ø D H W
1/2"ø D H W
R
1/2"ø D H W
2 1/2"ø D C W
1/
2" ø D
C W
1/ 2" ø D H W
R
1" ø D
H W
1"ø D C W
1"ø D H W
3/4"ø DCW 3/4"ø DHW
1/
2" ø D
C W
1/ 2" ø D H W
R 1" ø D H W
2" ø D
C W
1/ 2" ø D H W
R
1" ø D
H W
1/2"ø D H W
R
1"ø D H W
2"ø D C W
3/4"ø D H W
R
1 1/4"ø D H W
1/ 2" ø D H W
R
1/
4" ø
D H W
2" ø D
C W
1" ø D
H W
3/4"ø D C W
3/4"ø D H W
3/4"ø D H W
1 1/4"ø D C W
/4
"ø D
H W
R
/4 "ø
D H
W
1/2"ø DHWR
1 1/4"ø DHW 2 1/2"ø DCW
1/ 2" ø D H W1
1/ 4" ø D C W
/2 "ø
D C
W
/2 "ø
D H
W /4
"ø D
H W
R
3/4"ø DCW
1/2"ø D C W
3/4"ø D C W
1"ø DHW
1/2"ø DHWR
P-701
P-104
P-401
1 1/2"ø DCW
1"ø DHW
1/2"ø DHWR
IMB-1
TRAUMA ROOM
1G29
TRAUMA ROOM
1G31
ISOLATION EXAM
1G33A
ANTE ROOM
1G33
ISOLATION EXAM
1G35
TOILET
1G33B
STAFF WC/SHOWER
1G47A
STAFF LOUNGE
1G27
EQUIPMENT
1G25
VESTIBULE
1G00DA
EXAM
1G17
EXAM
1G15
EXAM
1G13
BARIATRIC EXAM
1G08
EXAM
1G10
EXAM
1G12
MEDS
1G22A
TOILET
1G06
TOILET
1G04
DISASTER/DECON SUPPLY
1G23
DECON ROOM
1G21
EMS SUPPLY
1G19A
STAT LAB
1G00GB
ALCOVE
1G00GA
HALL
1G00G
NURSE WORK N
1G14
PHYS. WORK
1G16
NURSE WORK S
1G18
HALL
1G00P
HALL
1G00E
NOURISHMENT
1G22
CLEAN LINEN
1G22B
PHARM. WK.
1G00E.01
UM WK.
1G00E.02
X-RAY
1G20
CHARTING
1G00FA
CORRIDOR
1G00O
1G00HA
NURSE SUPER.
1G37
BREAK ROOM
1B45A
ARMORY
1B45B
IT ROOM
1B47
SOILED UTILITY
1G49
HALL
1G00D
HALL
1G00C
SECLUSION
1G51
HALL
1B00E
CORRIDOR
1G00O
SHARED EDUCATION
1G45
STAFF WC
1G47
FIRE RISER CLOSET
1G19B
EXAM
1G11
HALL
1G00P
MATCHLINE AREA B
MATCHLINE AREA D
M A
T C
H L
IN
E A
R E
A C
M A
T C
H L
IN
E A
R E
A B
MATCHLINE AREA A
MATCHLINE AREA B
A
B C
D
A
B
C
D
E
F o n e e ig h t in c h o n e f o o t o n e q u a rt e r in c h o n e f o o t th re e e ig h th s i n c h o n e f o o t o n e h a lf i n c h o n e f o o t th re e q u a rt e rs i n c h o n e f o o t o n e i n c h o n e f o o t o n e a n d o n e h a lf i n c h e s o n e f o o t th re e i n c h e s o n e f o o t
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
F
IN
A L C
O N
S T
R U
C T
IO
N
D O
C U
M E
N T
S
CONSULTANTS: ARCHITECT / ENGINEERS: SEAL:
Revisions: Date:
Drawing Title
Approved: Project Director
Project Title
Location
Date Checked Drawn
Drawing Number
Building Number
Project Number
Dwg. _____ of _____197
URGENT CARE AND SUPPORT EXPANSION
VAMC SALT LAKE CITY, UTAH 84148
BOOGAARD GARTELL
660-332
PL101B
LEVEL 1 PLUMBING PLAN - DW - AREA B
08-11-2015
SCALE: 3/16" = 1'-0"F1
DOMESTIC WATER PLAN - AREA B
NORTH
0 2' 4' 8'
SCALE: NTS
KEY PLAN - AREA B
1 SEE PL101C FOR CONTINUATION
2 SEE PL101A FOR CONTINUATION
3 CAPPED AND VALVED FOR FUTURE.
4 PROVIDE BALANCING VALVE AND SET TO 0.5 GPM.
5 SEE PL101D FOR CONTINUATION
H H
E.1
E.1
2.5
E26
G
2.9
2.3
2.7
D.8
E26A
RF
RF
F.5
E
E
C.9
C.9 5
E.5
E.5
F
F.4
E.7
E.4
E.4
P-104 P-701
P-401P-701
P-104
RCP-1
P-401P-505
P-413
P-413
P-413
P-413
P-413
P-604
P-401
P-104
P-701
P-104
P-401
P-413
P-503
P-104
P-401
P-413
IMB-1
1/
2" ø
D C W
3/ 4" ø D H W
1/ 2" ø D H W
R
1/
2" ø
D C W
1" ø D
H W
1/ 2" ø D H W
R 1 1/4"ø D C W
3/4"ø D H W
1/2"ø D H W1 1/4"ø D
C W
3/4"ø D H W
1 1/2"ø D C W
1/ 2" ø D H W
R
3/ 4" ø D H W
1/
2" ø D
C W
3/4"ø D C W
3/4"ø D H W
1/2"ø D H W
R
1"ø D H W
2"ø D C W
1/2"ø D H W
R
3/4"ø D H W
2"ø D C W 1
1/ 2" ø D C W
3/ 4" ø D H W
3/ 4" ø D C W3/
4" ø D
H
WP-104
3/ 4" ø D H W
1/
2" ø D
C W
3/4"ø D H W1 1/4"ø D
C W
1/2"ø D C W
/4 "ø
D H
W
/4
"ø D
H W
R
EXAM
1G61
EXAM
1G59
EXAM
1G57
EXAM
1G55
EXAM
1G53
CORRIDOR
1G00M
EM ELEC. ROOM
1G83
ELECTRICAL ROOM
1G85
BIOMED
1G87
SECLUSION
1G51
X-RAY
1G20
MH CLINICAL OFFICE
1G24
HALL
1G00K
CLEAN SUPPLY
1G22D
NOURISHMENT
1G22
CLEAN LINEN
1G22B
EVS
1G22C
MEDS
1G22A
EXAM
1G12
FAST TRACK/EXAM
1G67
HALL
1G00C
TOILET
1G65
SHOWER
1G65A
INTERNAL WAITING
1G63
VIS. TOILET
1G79
MENS WC
1B45D
MENS SHOWER
1B45DA
WOMENS SHOWER
1B45CA
CORRIDOR
1G00O
IT ROOM
1B47
UM WK.
1G00E.02
PHARM. WK.
1G00E.01
CHARTING
1G00FA
ARMORY
1B45B
GENERATOR
1G81
FAST TRACK/EXAM
1G69
HALL
1G00C
TOILET
1G04
HALL
1G00E
MATCHLINE AREA C
MATCHLINE AREA D
M A
T C
H L
IN
E A
R E
A C
M A
T C
H L
IN
E A
R E
A B
MATCHLINE AREA A
MATCHLINE AREA C
HB-2
A
B C
D
DEDUCT ALTERNATE K: SHELL RECEPTION, PATIENT WAITING, CONSULT
ROOM, ENROLLMENT, VISITOR TOILET, AND WRAP AROUND CORRIDOR. DO
NOT COMPLETE ANY OF THE INTERIOR WALLS, DOORS, FINISHES,
MECHANICAL, ELECTRICAL, PLUMBING AND FIRE. COMPLETE THE
EXTERIOR WALLS WITH INSULATION AND VAPOR BARRIER (BUT NO
INTERIOR GYPSUM BOARD) AND ELECTRICAL ROUGH-IN. SEE AE001 FOR
FURTHER INFORMATION.
A
B
C
D
E
F o n e e ig h t in c h o n e f o o t o n e q u a rt e r in c h o n e f o o t th re e e ig h th s i n c h o n e f o o t o n e h a lf i n c h o n e f o o t th re e q u a rt e rs i n c h o n e f o o t o n e i n c h o n e f o o t o n e a n d o n e h a lf i n c h e s o n e f o o t th re e i n c h e s o n e f o o t
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
F
IN
A L C
O N
S T
R U
C T
IO
N
D O
C U
M E
N T
S
CONSULTANTS: ARCHITECT / ENGINEERS: SEAL:
Revisions: Date:
Drawing Title
Approved: Project Director
Project Title
Location
Date Checked Drawn
Drawing Number
Building Number
Project Number
Dwg. _____ of _____197
URGENT CARE AND SUPPORT EXPANSION
VAMC SALT LAKE CITY, UTAH 84148
BOOGAARD GARTELL
660-332
PL101C
LEVEL 1 PLUMBING PLAN - DW - AREA C
08-11-2015
SCALE: 3/16" = 1'-0"F2
DOMESTIC WATER PLAN - AREA C
NORTH
0 2' 4' 8'
REF SHEET: 1" = 200'-0"
KEY PLAN - AREA C
1 1/2" WATER LINE UP TO HUMIDIFIER ABOVE.
2 SEE PL101A FOR CONTINUATION.
3 SEE PL101D FOR CONTINUATION.
4 PROVIDE BALANCING VALVE AND SET TO 0.5 GPM.
5 PROVIDE DOUBLE CHECK VALVE AT WATER PIPING TO SERVICE SINK. PROVIDE A
SEPARATE HOSE BIBB WITH VACUUM BREAKER FOR USE WITH CLEANING
CHEMICAL STATION..
R6
R6
R7
R7
E.1
E.1
RG
RD
RB
R4
R3
R3
RC
R5
RE
O
O
RA
RA
RF
RF
RH
E
E
C.9
C.9
E.5
E.5
E.7
E.4
E.4
P-413
P-413
P-401
P-104
P-503
P-413
P-413
P-413
P-401
P-104
P-413
P-413
P-413
P-413
P-701
P-104
P-401
P-401
P-104
P-604
P-104 P-413
1/ 2" ø D H W
R
1" ø D
H W
2" ø D
C W
1/2"ø D H W
R
1"ø D H W
2"ø D C W
2"ø D C W1"ø D
H W
1/2"ø D H W
R
1/
4" ø
D C W
1/ 2" ø D H W
/2
"ø D
C W
1/2"ø DCW
EXAM
1G09
EXAM
1G11
EXAM
1G13
EXAM
1G15
EXAM
1G17
EXAM
1G07
OB/GYN Exam
1G05
TOILET
1G04
HALL
1G00D
TOILET
1G06
EVS
1G22C
TRIAGE
1G00BA
REC / ENROLLMENT / POLICE
1G73
FAST TRACK/EXAM
1G71
FAST TRACK/EXAM
1G69
FAST TRACK/EXAM
1G67
ENROLLMENT
1G75
SHOWER
1G65A
VIS. TOILET
1G79
CORRIDOR
1G00M
VIS. TOILET
1G77
HALL
1G00B
HALL
1G00C
VESTIBULE
1G00A
WAITING ROOM
1G01
HALL
1G00
H-1
3/4"ø D C W
MATCHLINE AREA B
MATCHLINE AREA D
MATCHLINE AREA C
MATCHLINE AREA D
A
B C
D
DEDUCT ALTERNATE K: SHELL RECEPTION, PATIENT WAITING, CONSULT
ROOM, ENROLLMENT, VISITOR TOILET, AND WRAP AROUND CORRIDOR. DO
NOT COMPLETE ANY OF THE INTERIOR WALLS, DOORS, FINISHES,
MECHANICAL, ELECTRICAL, PLUMBING AND FIRE. COMPLETE THE
EXTERIOR WALLS WITH INSULATION AND VAPOR BARRIER (BUT NO
INTERIOR GYPSUM BOARD) AND ELECTRICAL ROUGH-IN. SEE AE001 FOR
FURTHER INFORMATION.
A
B
C
D
E
F o n e e ig h t in c h o n e f o o t o n e q u a rt e r in c h o n e f o o t th re e e ig h th s i n c h o n e f o o t o n e h a lf i n c h o n e f o o t th re e q u a rt e rs i n c h o n e f o o t o n e i n c h o n e f o o t o n e a n d o n e h a lf i n c h e s o n e f o o t th re e i n c h e s o n e f o o t
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
F
IN
A L C
O N
S T
R U
C T
IO
N
D O
C U
M E
N T
S
CONSULTANTS: ARCHITECT / ENGINEERS: SEAL:
Revisions: Date:
Drawing Title
Approved: Project Director
Project Title
Location
Date Checked Drawn
Drawing Number
Building Number
Project Number
Dwg. _____ of _____197
URGENT CARE AND SUPPORT EXPANSION
VAMC SALT LAKE CITY, UTAH 84148
BOOGAARD GARTELL
660-332
PL101D
LEVEL 1 PLUMBING PLAN - DW - AREA D
08-11-2015
SCALE: 3/16" = 1'-0"F2
DOMESTIC WATER PLAN - AREA D
NORTH
0 2' 4' 8'
SCALE: NTS
KEY PLAN - AREA D
1 SEE PL101B FOR CONTINUATION.
2 PROVIDE 1/2" WATER LINE TO MIST FIREPLACE. PROVIDE SHUTOFF VALVE IN
ACCESSIBLE LOCATION IN CEILING.
(E)DHWR
(E)DHW
(E)DCW
(E)V
(E)SS3
/2
"ø D
H W
/2
"ø D
C W
/2
"ø D
H W
R
"ø
V
2"ø SS
DIRECTOR
1A23E
CHIEF OF STAFF
1A23F
ASSOCIATE DIRECTOR
1A23G
BOARD ROOM
1A23H
BOARD ROOM
1A23H
HALL
1A00
STORAGE
1A21A
ASSOCIATE DIRECTOR FOR QUALITY
AND SAFETY
1A23A
ASSOCIATE DIRECTOR FOR PATIENT
CARE SERVICES
1A23B
CHEIF OF COMMUNICATIONS
1A23C
CONSULTATION
1A23D
CUBICLE
1A23.02
CUBICLE
1A23.01
CUBICLE
1A23.03
CUBICLE
1A23.04
CUBICLE
1A23.06
CUBICLE
1A23.05
CUBICLE
1A23.09
CUBICLE
1A23.07
BREAK ROOM
1A23.08
CUBICLE
1A23.12
CUBICLE
1A23.11
DIRECTORS SECRETARY
1A23.10
STAIR
1AB
22222
A
B
C
D
E
F o n e e ig h t in c h o n e f o o t o n e q u a rt e r in c h o n e f o o t th re e e ig h th s i n c h o n e f o o t o n e h a lf i n c h o n e f o o t th re e q u a rt e rs i n c h o n e f o o t o n e i n c h o n e f o o t o n e a n d o n e h a lf i n c h e s o n e f o o t th re e i n c h e s o n e f o o t
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
F
IN
A L C
O N
S T
R U
C T
IO
N
D O
C U
M E
N T
S
CONSULTANTS: ARCHITECT / ENGINEERS: SEAL:
Revisions: Date:
Drawing Title
Approved: Project Director
Project Title
Location
Date Checked Drawn
Drawing Number
Building Number
Project Number
Dwg. _____ of _____197
URGENT CARE AND SUPPORT EXPANSION
VAMC SALT LAKE CITY, UTAH 84148
BOOGAARD GARTELL
660-332
PL102
ADMIN AREA PLUMBING PLANS
08-11-2015
SCALE: 1/8" = 1'-0"C2
NEW ADMIN AREA WASTE AND VENT DEMOLITION PLAN
SCALE: 1/8" = 1'-0"F2
NEW ADMIN AREA WASTE AND VENT PLAN
1 PROVIDE NEW BALANCING VALVE AND SET TO 0.5 GPM.
2 CONNECT TO EXISTING PIPING IN THIS APPROXIMATE LOCATION. FIELD VERIFY.
3 REMOVE EXISTING SINK. SEE NEW PLAN FOR PIPING TIES INS TO EXISTING
PIPING.
4 REMOVE EXISTING SINK AND ASSOCIATED PIPING BACK TO MAIN AND CAP.
31 32
R6
R6
R7
R7
1.3
A
H
B
C
D
E.1
2.5
M
K
J
RG
RD
RB
EV
EX
EW
R4
R3
R2
EU
E18
E21 E23 E26
RC
G
D.2
2.9
H.8
L
2.1 2.3 2.7
R5
E24
D.8
E33B
E26A
RE
O
RA
RF
RF
F.5
RH
E
C.9
C.9
E.5
F F.4
E.7
R1
E.4
DN-1
DN-1
DN-2
DN-1
DN-1
DN-2
DN-2
DECON ROOM
1G21
EMS SUPPLY
1G19A
STAT LAB
1G00GB
ALCOVE
1G00GA
VESTIBULE
1G00DA
EXAM
1G17
EXAM
1G15
EXAM
1G13
EXAM
1G11
EXAM
1G09
EXAM
1G07
OB/GYN Exam
1G05
OB toilet
1G05A
FAMILY CONSULT
1G03
VESTIBULE
1G00A
HALL
1G00B
HALL
1G00
WAITING ROOM
1G01
REC / ENROLLMENT / POLICE
1G73
TRIAGE
1G00BA
FAST TRACK/EXAM
1G71
FAST TRACK/EXAM
1G69
FAST TRACK/EXAM
1G67
VIS. TOILET
1G77
ENROLLMENT
1G75
CORRIDOR
1G00M
INTERNAL WAITING
1G63
SHOWER
1G65A
VIS. TOILET
1G79
TOILET
1G65
EXAM
1G61
EXAM
1G59
EXAM
1G57
HALL
1G00K
CLEAN SUPPLY
1G22D
MH CLINICAL OFFICE
1G24
GENERATOR
1G81
EM ELEC. ROOM
1G83
ELECTRICAL ROOM
1G85
BIOMED
1G87
MENS SHOWER
1B45DA
MENS WC
1B45D
WOMENS WC
1B45C
WOMENS SHOWER
1B45CAIT ROOM
1B47
OFFICER
1B45.01
OFFICER
1B45.02
EVIDENCE
1B45G
OFFICER
1B45.05
OFFICER
1B45.04
OFFICER
1B45.03
HALL
1B45
DISPATCH
1B45H
ARMORY
1B45B
BREAK ROOM
1B45A
PSA
1B43A.01
VESTIBULE
1B43
INTERVIEW
1B43B
STORAGE
1B41
HOLD
1B43AA
Hall
1B43A
STORAGE
1B45F
OFFICER
1B45.06
OFFICER
1B45.07
CHIEF
1B45E
HALL
1B00E
SHARED CONFERENCE
1G43
ON-CALL
1G41
HALL
1G00J
ER DIRECTOR
1G39
HALL
1B00G
OFFICE
1B22
1G00HA
HALL
1G00H
HALL
1G00P CHARTING
1G00FA
CORRIDOR
1G00O
SOILED UTILITY
1G49
SECLUSION
1G51
CORRIDOR
1G00N
EXAM
1G55
EXAM
1G53
UM WK.
1G00E.02
X-RAY
1G20
PHARM. WK.
1G00E.01
NOURISHMENT
1G22
MEDS
1G22A
EXAM
1G12
EXAM
1G10
BARIATRIC EXAM
1G08
TOILET
1G06
TOILET
1G04
CLEAN LINEN
1G22B
EVS
1G22C
HALL
1G00C
HALL
1G00D
HALL
1G00G
EQUIPMENT
1G25
TRAUMA ROOM
1G29
TRAUMA ROOM
1G31
STAFF LOUNGE
1G27
STAFF WC/SHOWER
1G47A
STAFF WC
1G47
SHARED EDUCATION
1G45
HALL
1G00I
ISOLATION EXAM
1G33A
ANTE ROOM
1G33
ISOLATION EXAM
1G35
NURSE WORK S
1G18
PHYS. WORK
1G16
NURSE WORK N
1G14
HALL
1G00P
HALL
1G00E
ALCOVE
1G00GA
2 3
MATCHLINE AREA B
MATCHLINE AREA D
MATCHLINE AREA C
MATCHLINE AREA D
M A
T C
H L
IN
E A
R E
A C
M A
T C
H L
IN
E A
R E
A B
MATCHLINE AREA A
MATCHLINE AREA C
MATCHLINE AREA A
MATCHLINE AREA B
A
B
C
D
E
F o n e e ig h t in c h o n e f o o t o n e q u a rt e r in c h o n e f o o t th re e e ig h th s i n c h o n e f o o t o n e h a lf i n c h o n e f o o t th re e q u a rt e rs i n c h o n e f o o t o n e i n c h o n e f o o t o n e a n d o n e h a lf i n c h e s o n e f o o t th re e i n c h e s o n e f o o t
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
F
IN
A L C
O N
S T
R U
C T
IO
N
D O
C U
M E
N T
S
CONSULTANTS: ARCHITECT / ENGINEERS: SEAL:
Revisions: Date:
Drawing Title
Approved: Project Director
Project Title
Location
Date Checked Drawn
Drawing Number
Building Number
Project Number
Dwg. _____ of _____197
URGENT CARE AND SUPPORT EXPANSION
VAMC SALT LAKE CITY, UTAH 84148
BOOGAARD GARTELL
660-332
PL111
DRAIN WASTE AND VENT PLAN
08-11-2015
SCALE: 3/32" = 1'-0"F1
OVERALL DRAIN WASTE AND VENT PLAN
NORTH
0 6' 12' 24' SCALE: NTS
KEY PLAN - URGENT CARE
1 50 GALLON HOLDING TANK. PROVIDE WITH VENT CONNECTION AND TOP PUMP
OUT OPENING. PROVIDE WITH ALARM AT 50% AND 75% FULL. COORDINATE WITH
GC TO PROVIDE MANHOLE COVER.
2 PROVIDE MANUAL DIVERTING VALVE. NORMALLY CLOSED. PROVIDE WITH FLOOR
COVER.
3 PROVIDE MANUAL DIVERTING VALVE. NORMALLY OPEN. PROVIDE WITH FLOOR
COVER.
4 CONNECT TO EXISTING AREA WELL. SEE CIVIL SITE UTILITY PLAN.
| PE001 - PLUMBING COVER SHEET |
| Sheets |
| PD101 - LEVEL 1 PLUMBING PLAN - DEMOLITION |
| PE001 - PLUMBING COVER SHEET |
| PE501 - PLUMBING DETAILS |
| PE601 - PLUMBING SCHEDULES |
| PL101 - DOMESTIC WATER PIPING PLAN |
| PL101A - LEVEL 1 PLUMBING PLAN - DW - AREA A |
| PL101B - LEVEL 1 PLUMBING PLAN - DW - AREA B |
| PL101C - LEVEL 1 PLUMBING PLAN - DW - AREA C |
| PL101D - LEVEL 1 PLUMBING PLAN - DW - AREA D |
| PL102 - ADMIN AREA PLUMBING PLANS |
| PL111 - DRAIN WASTE AND VENT PLAN |
| PL111A - LEVEL 1 PLUMBING PLAN - DWV - AREA A |
| PL111B - LEVEL 1 PLUMBING PLAN - DWV - AREA B |
| PL111C - LEVEL 1 PLUMBING PLAN - DWV - AREA C |
| PL111D - LEVEL 1 PLUMBING PLAN - DWV - AREA D |
| PL112 - ROOF PLUMBING PLAN |
| PL121 - MEDICAL GAS PIPING PLAN |
| PL121A - LEVEL 1 MEDICAL GAS PIPING PLAN - AREA A |
| PL121B - LEVEL 1 MEDICAL GAS PIPING PLAN - AREA B |
| PL121C - LEVEL 1 MEDICAL GAS PIPING PLAN - AREA C |
| PL121D - LEVEL 1 MEDICAL GAS PIPING PLAN - AREA D |
| PE501 - PLUMBING DETAILS |
| Sheets |
| PD101 - LEVEL 1 PLUMBING PLAN - DEMOLITION |
| PE001 - PLUMBING COVER SHEET |
| PE501 - PLUMBING DETAILS |
| PE601 - PLUMBING SCHEDULES |
| PL101 - DOMESTIC WATER PIPING PLAN |
| PL101A - LEVEL 1 PLUMBING PLAN - DW - AREA A |
| PL101B - LEVEL 1 PLUMBING PLAN - DW - AREA B |
| PL101C - LEVEL 1 PLUMBING PLAN - DW - AREA C |
| PL101D - LEVEL 1 PLUMBING PLAN - DW - AREA D |
| PL102 - ADMIN AREA PLUMBING PLANS |
| PL111 - DRAIN WASTE AND VENT PLAN |
| PL111A - LEVEL 1 PLUMBING PLAN - DWV - AREA A |
| PL111B - LEVEL 1 PLUMBING PLAN - DWV - AREA B |
| PL111C - LEVEL 1 PLUMBING PLAN - DWV - AREA C |
| PL111D - LEVEL 1 PLUMBING PLAN - DWV - AREA D |
| PL112 - ROOF PLUMBING PLAN |
| PL121 - MEDICAL GAS PIPING PLAN |
| PL121A - LEVEL 1 MEDICAL GAS PIPING PLAN - AREA A |
| PL121B - LEVEL 1 MEDICAL GAS PIPING PLAN - AREA B |
| PL121C - LEVEL 1 MEDICAL GAS PIPING PLAN - AREA C |
| PL121D - LEVEL 1 MEDICAL GAS PIPING PLAN - AREA D |
| PE601 - PLUMBING SCHEDULES |
| Sheets |
| PD101 - LEVEL 1 PLUMBING PLAN - DEMOLITION |
| PE001 - PLUMBING COVER SHEET |
| PE501 - PLUMBING DETAILS |
| PE601 - PLUMBING SCHEDULES |
| PL101 - DOMESTIC WATER PIPING PLAN |
| PL101A - LEVEL 1 PLUMBING PLAN - DW - AREA A |
| PL101B - LEVEL 1 PLUMBING PLAN - DW - AREA B |
| PL101C - LEVEL 1 PLUMBING PLAN - DW - AREA C |
| PL101D - LEVEL 1 PLUMBING PLAN - DW - AREA D |
| PL102 - ADMIN AREA PLUMBING PLANS |
| PL111 - DRAIN WASTE AND VENT PLAN |
| PL111A - LEVEL 1 PLUMBING PLAN - DWV - AREA A |
| PL111B - LEVEL 1 PLUMBING PLAN - DWV - AREA B |
| PL111C - LEVEL 1 PLUMBING PLAN - DWV - AREA C |
| PL111D - LEVEL 1 PLUMBING PLAN - DWV - AREA D |
| PL112 - ROOF PLUMBING PLAN |
| PL121 - MEDICAL GAS PIPING PLAN |
| PL121A - LEVEL 1 MEDICAL GAS PIPING PLAN - AREA A |
| PL121B - LEVEL 1 MEDICAL GAS PIPING PLAN - AREA B |
| PL121C - LEVEL 1 MEDICAL GAS PIPING PLAN - AREA C |
| PL121D - LEVEL 1 MEDICAL GAS PIPING PLAN - AREA D |
| PD101 - LEVEL 1 PLUMBING PLAN - DEMOLITION |
| Sheets |
| PD101 - LEVEL 1 PLUMBING PLAN - DEMOLITION |
| PE001 - PLUMBING COVER SHEET |
| PE501 - PLUMBING DETAILS |
| PE601 - PLUMBING SCHEDULES |
| PL101 - DOMESTIC WATER PIPING PLAN |
| PL101A - LEVEL 1 PLUMBING PLAN - DW - AREA A |
| PL101B - LEVEL 1 PLUMBING PLAN - DW - AREA B |
| PL101C - LEVEL 1 PLUMBING PLAN - DW - AREA C |
| PL101D - LEVEL 1 PLUMBING PLAN - DW - AREA D |
| PL102 - ADMIN AREA PLUMBING PLANS |
| PL111 - DRAIN WASTE AND VENT PLAN |
| PL111A - LEVEL 1 PLUMBING PLAN - DWV - AREA A |
| PL111B - LEVEL 1 PLUMBING PLAN - DWV - AREA B |
| PL111C - LEVEL 1 PLUMBING PLAN - DWV - AREA C |
| PL111D - LEVEL 1 PLUMBING PLAN - DWV - AREA D |
| PL112 - ROOF PLUMBING PLAN |
| PL121 - MEDICAL GAS PIPING PLAN |
| PL121A - LEVEL 1 MEDICAL GAS PIPING PLAN - AREA A |
| PL121B - LEVEL 1 MEDICAL GAS PIPING PLAN - AREA B |
| PL121C - LEVEL 1 MEDICAL GAS PIPING PLAN - AREA C |
| PL121D - LEVEL 1 MEDICAL GAS PIPING PLAN - AREA D |
| PL101 - DOMESTIC WATER PIPING PLAN |
| Sheets |
| PD101 - LEVEL 1 PLUMBING PLAN - DEMOLITION |
| PE001 - PLUMBING COVER SHEET |
| PE501 - PLUMBING DETAILS |
| PE601 - PLUMBING SCHEDULES |
| PL101 - DOMESTIC WATER PIPING PLAN |
| PL101A - LEVEL 1 PLUMBING PLAN - DW - AREA A |
| PL101B - LEVEL 1 PLUMBING PLAN - DW - AREA B |
| PL101C - LEVEL 1 PLUMBING PLAN - DW - AREA C |
| PL101D - LEVEL 1 PLUMBING PLAN - DW - AREA D |
| PL102 - ADMIN AREA PLUMBING PLANS |
| PL111 - DRAIN WASTE AND VENT PLAN |
| PL111A - LEVEL 1 PLUMBING PLAN - DWV - AREA A |
| PL111B - LEVEL 1 PLUMBING PLAN - DWV - AREA B |
| PL111C - LEVEL 1 PLUMBING PLAN - DWV - AREA C |
| PL111D - LEVEL 1 PLUMBING PLAN - DWV - AREA D |
| PL112 - ROOF PLUMBING PLAN |
| PL121 - MEDICAL GAS PIPING PLAN |
| PL121A - LEVEL 1 MEDICAL GAS PIPING PLAN - AREA A |
| PL121B - LEVEL 1 MEDICAL GAS PIPING PLAN - AREA B |
| PL121C - LEVEL 1 MEDICAL GAS PIPING PLAN - AREA C |
| PL121D - LEVEL 1 MEDICAL GAS PIPING PLAN - AREA D |
| PL101A - LEVEL 1 PLUMBING PLAN - DW - AREA A |
| Sheets |
| PD101 - LEVEL 1 PLUMBING PLAN - DEMOLITION |
| PE001 - PLUMBING COVER SHEET |
| PE501 - PLUMBING DETAILS |
| PE601 - PLUMBING SCHEDULES |
| PL101 - DOMESTIC WATER PIPING PLAN |
| PL101A - LEVEL 1 PLUMBING PLAN - DW - AREA A |
| PL101B - LEVEL 1 PLUMBING PLAN - DW - AREA B |
| PL101C - LEVEL 1 PLUMBING PLAN - DW - AREA C |
| PL101D - LEVEL 1 PLUMBING PLAN - DW - AREA D |
| PL102 - ADMIN AREA PLUMBING PLANS |
| PL111 - DRAIN WASTE AND VENT PLAN |
| PL111A - LEVEL 1 PLUMBING PLAN - DWV - AREA A |
| PL111B - LEVEL 1 PLUMBING PLAN - DWV - AREA B |
| PL111C - LEVEL 1 PLUMBING PLAN - DWV - AREA C |
| PL111D - LEVEL 1 PLUMBING PLAN - DWV - AREA D |
| PL112 - ROOF PLUMBING PLAN |
| PL121 - MEDICAL GAS PIPING PLAN |
| PL121A - LEVEL 1 MEDICAL GAS PIPING PLAN - AREA A |
| PL121B - LEVEL 1 MEDICAL GAS PIPING PLAN - AREA B |
| PL121C - LEVEL 1 MEDICAL GAS PIPING PLAN - AREA C |
| PL121D - LEVEL 1 MEDICAL GAS PIPING PLAN - AREA D |
| PL101B - LEVEL 1 PLUMBING PLAN - DW - AREA B |
| Sheets |
| PD101 - LEVEL 1 PLUMBING PLAN - DEMOLITION |
| PE001 - PLUMBING COVER SHEET |
| PE501 - PLUMBING DETAILS |
| PE601 - PLUMBING SCHEDULES |
| PL101 - DOMESTIC WATER PIPING PLAN |
| PL101A - LEVEL 1 PLUMBING PLAN - DW - AREA A |
| PL101B - LEVEL 1 PLUMBING PLAN - DW - AREA B |
| PL101C - LEVEL 1 PLUMBING PLAN - DW - AREA C |
| PL101D - LEVEL 1 PLUMBING PLAN - DW - AREA D |
| PL102 - ADMIN AREA PLUMBING PLANS |
| PL111 - DRAIN WASTE AND VENT PLAN |
| PL111A - LEVEL 1 PLUMBING PLAN - DWV - AREA A |
| PL111B - LEVEL 1 PLUMBING PLAN - DWV - AREA B |
| PL111C - LEVEL 1 PLUMBING PLAN - DWV - AREA C |
| PL111D - LEVEL 1 PLUMBING PLAN - DWV - AREA D |
| PL112 - ROOF PLUMBING PLAN |
| PL121 - MEDICAL GAS PIPING PLAN |
| PL121A - LEVEL 1 MEDICAL GAS PIPING PLAN - AREA A |
| PL121B - LEVEL 1 MEDICAL GAS PIPING PLAN - AREA B |
| PL121C - LEVEL 1 MEDICAL GAS PIPING PLAN - AREA C |
| PL121D - LEVEL 1 MEDICAL GAS PIPING PLAN - AREA D |
| PL101C - LEVEL 1 PLUMBING PLAN - DW - AREA C |
| Sheets |
| PD101 - LEVEL 1 PLUMBING PLAN - DEMOLITION |
| PE001 - PLUMBING COVER SHEET |
| PE501 - PLUMBING DETAILS |
| PE601 - PLUMBING SCHEDULES |
| PL101 - DOMESTIC WATER PIPING PLAN |
| PL101A - LEVEL 1 PLUMBING PLAN - DW - AREA A |
| PL101B - LEVEL 1 PLUMBING PLAN - DW - AREA B |
| PL101C - LEVEL 1 PLUMBING PLAN - DW - AREA C |
| PL101D - LEVEL 1 PLUMBING PLAN - DW - AREA D |
| PL102 - ADMIN AREA PLUMBING PLANS |
| PL111 - DRAIN WASTE AND VENT PLAN |
| PL111A - LEVEL 1 PLUMBING PLAN - DWV - AREA A |
| PL111B - LEVEL 1 PLUMBING PLAN - DWV - AREA B |
| PL111C - LEVEL 1 PLUMBING PLAN - DWV - AREA C |
| PL111D - LEVEL 1 PLUMBING PLAN - DWV - AREA D |
| PL112 - ROOF PLUMBING PLAN |
| PL121 - MEDICAL GAS PIPING PLAN |
| PL121A - LEVEL 1 MEDICAL GAS PIPING PLAN - AREA A |
| PL121B - LEVEL 1 MEDICAL GAS PIPING PLAN - AREA B |
| PL121C - LEVEL 1 MEDICAL GAS PIPING PLAN - AREA C |
| PL121D - LEVEL 1 MEDICAL GAS PIPING PLAN - AREA D |
| PL101D - LEVEL 1 PLUMBING PLAN - DW - AREA D |
| Sheets |
| PD101 - LEVEL 1 PLUMBING PLAN - DEMOLITION |
| PE001 - PLUMBING COVER SHEET |
| PE501 - PLUMBING DETAILS |
| PE601 - PLUMBING SCHEDULES |
| PL101 - DOMESTIC WATER PIPING PLAN |
| PL101A - LEVEL 1 PLUMBING PLAN - DW - AREA A |
| PL101B - LEVEL 1 PLUMBING PLAN - DW - AREA B |
| PL101C - LEVEL 1 PLUMBING PLAN - DW - AREA C |
| PL101D - LEVEL 1 PLUMBING PLAN - DW - AREA D |
| PL102 - ADMIN AREA PLUMBING PLANS |
| PL111 - DRAIN WASTE AND VENT PLAN |
| PL111A - LEVEL 1 PLUMBING PLAN - DWV - AREA A |
| PL111B - LEVEL 1 PLUMBING PLAN - DWV - AREA B |
| PL111C - LEVEL 1 PLUMBING PLAN - DWV - AREA C |
| PL111D - LEVEL 1 PLUMBING PLAN - DWV - AREA D |
| PL112 - ROOF PLUMBING PLAN |
| PL121 - MEDICAL GAS PIPING PLAN |
| PL121A - LEVEL 1 MEDICAL GAS PIPING PLAN - AREA A |
| PL121B - LEVEL 1 MEDICAL GAS PIPING PLAN - AREA B |
| PL121C - LEVEL 1 MEDICAL GAS PIPING PLAN - AREA C |
| PL121D - LEVEL 1 MEDICAL GAS PIPING PLAN - AREA D |
| PL102 - ADMIN AREA PLUMBING PLANS |
| Sheets |
| PD101 - LEVEL 1 PLUMBING PLAN - DEMOLITION |
| PE001 - PLUMBING COVER SHEET |
| PE501 - PLUMBING DETAILS |
| PE601 - PLUMBING SCHEDULES |
| PL101 - DOMESTIC WATER PIPING PLAN |
| PL101A - LEVEL 1 PLUMBING PLAN - DW - AREA A |
| PL101B - LEVEL 1 PLUMBING PLAN - DW - AREA B |
| PL101C - LEVEL 1 PLUMBING PLAN - DW - AREA C |
| PL101D - LEVEL 1 PLUMBING PLAN - DW - AREA D |
| PL102 - ADMIN AREA PLUMBING PLANS |
| PL111 - DRAIN WASTE AND VENT PLAN |
| PL111A - LEVEL 1 PLUMBING PLAN - DWV - AREA A |
| PL111B - LEVEL 1 PLUMBING PLAN - DWV - AREA B |
| PL111C - LEVEL 1 PLUMBING PLAN - DWV - AREA C |
| PL111D - LEVEL 1 PLUMBING PLAN - DWV - AREA D |
| PL112 - ROOF PLUMBING PLAN |
| PL121 - MEDICAL GAS PIPING PLAN |
| PL121A - LEVEL 1 MEDICAL GAS PIPING PLAN - AREA A |
| PL121B - LEVEL 1 MEDICAL GAS PIPING PLAN - AREA B |
| PL121C - LEVEL 1 MEDICAL GAS PIPING PLAN - AREA C |
| PL121D - LEVEL 1 MEDICAL GAS PIPING PLAN - AREA D |
| PL111 - DRAIN WASTE AND VENT PLAN |
| Sheets |
| PD101 - LEVEL 1 PLUMBING PLAN - DEMOLITION |
| PE001 - PLUMBING COVER SHEET |
| PE501 - PLUMBING DETAILS |
| PE601 - PLUMBING SCHEDULES |
| PL101 - DOMESTIC WATER PIPING PLAN |
| PL101A - LEVEL 1 PLUMBING PLAN - DW - AREA A |
| PL101B - LEVEL 1 PLUMBING PLAN - DW - AREA B |
| PL101C - LEVEL 1 PLUMBING PLAN - DW - AREA C |
| PL101D - LEVEL 1 PLUMBING PLAN - DW - AREA D |
| PL102 - ADMIN AREA PLUMBING PLANS |
| PL111 - DRAIN WASTE AND VENT PLAN |
| PL111A - LEVEL 1 PLUMBING PLAN - DWV - AREA A |
| PL111B - LEVEL 1 PLUMBING PLAN - DWV - AREA B |
| PL111C - LEVEL 1 PLUMBING PLAN - DWV - AREA C |
| PL111D - LEVEL 1 PLUMBING PLAN - DWV - AREA D |
| PL112 - ROOF PLUMBING PLAN |
| PL121 - MEDICAL GAS PIPING PLAN |
| PL121A - LEVEL 1 MEDICAL GAS PIPING PLAN - AREA A |
| PL121B - LEVEL 1 MEDICAL GAS PIPING PLAN - AREA B |
| PL121C - LEVEL 1 MEDICAL GAS PIPING PLAN - AREA C |
| PL121D - LEVEL 1 MEDICAL GAS PIPING PLAN - AREA D |
| PL111A - LEVEL 1 PLUMBING PLAN - DWV - AREA A |
| Sheets |
| PD101 - LEVEL 1 PLUMBING PLAN - DEMOLITION |
| PE001 - PLUMBING COVER SHEET |
| PE501 - PLUMBING DETAILS |
| PE601 - PLUMBING SCHEDULES |
| PL101 - DOMESTIC WATER PIPING PLAN |
| PL101A - LEVEL 1 PLUMBING PLAN - DW - AREA A |
| PL101B - LEVEL 1 PLUMBING PLAN - DW - AREA B |
| PL101C - LEVEL 1 PLUMBING PLAN - DW - AREA C |
| PL101D - LEVEL 1 PLUMBING PLAN - DW - AREA D |
| PL102 - ADMIN AREA PLUMBING PLANS |
| PL111 - DRAIN WASTE AND VENT PLAN |
| PL111A - LEVEL 1 PLUMBING PLAN - DWV - AREA A |
| PL111B - LEVEL 1 PLUMBING PLAN - DWV - AREA B |
| PL111C - LEVEL 1 PLUMBING PLAN - DWV - AREA C |
| PL111D - LEVEL 1 PLUMBING PLAN - DWV - AREA D |
| PL112 - ROOF PLUMBING PLAN |
| PL121 - MEDICAL GAS PIPING PLAN |
| PL121A - LEVEL 1 MEDICAL GAS PIPING PLAN - AREA A |
| PL121B - LEVEL 1 MEDICAL GAS PIPING PLAN - AREA B |
| PL121C - LEVEL 1 MEDICAL GAS PIPING PLAN - AREA C |
| PL121D - LEVEL 1 MEDICAL GAS PIPING PLAN - AREA D |
| PL111B - LEVEL 1 PLUMBING PLAN - DWV - AREA B |
| Sheets |
| PD101 - LEVEL 1 PLUMBING PLAN - DEMOLITION |
| PE001 - PLUMBING COVER SHEET |
| PE501 - PLUMBING DETAILS |
| PE601 - PLUMBING SCHEDULES |
| PL101 - DOMESTIC WATER PIPING PLAN |
| PL101A - LEVEL 1 PLUMBING PLAN - DW - AREA A |
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .