Attch11_8 Arch Drawings Part 2.pdf

PDF 16 MB Posted

Attached to
Y1DA--Emergency Department and Support Expansion / 660-800
Solicitation number
36C25920R0096
Issued by

About this file

This document provides details on a federal contract opportunity for emergency department and support expansion at the Salt Lake City VA Medical Center. The contractor will be responsible for providing all materials and labor to build an 18,500 square foot addition and renovate 4,000 square feet of existing space to create a new emergency department and associated police department. The project budget is between $10-20 million. The solicitation number is 36C25920R0096 and the opportunity type is a pre-solicitation notice, with the request for proposal expected to be posted on July 27, 2020. This procurement has a NAICS code of 236220 and is reserved 100% for Service-Disabled Veteran-Owned Small Businesses. Offerors must be verified and listed in the Vendor Information Pages database to be considered for award. The point of contact for questions is Rebeca Hinz of the Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 19.

View the file

Other files

Show all 22

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

WALL TYPE:

DOOR SCHEDULE

STOREFRONT HEAD DETAIL

SCALE: 3" = 1'-0"

STOREFRONT JAMB DETAIL

SCALE: 3" = 1'-0"

STOREFRONT JAMB DETAIL

SCALE: 3" = 1'-0"

STOREFRONT HEAD DETAIL

SCALE: 3" = 1'-0"

STOREFRONT JAMB DETAIL

SCALE: 3" = 1'-0"

Drawing Title

Approved: Project Director

Project Title

Date

Location

Checked

Building Number

Project Number

Drawing Number

Drawn

Dwg. of

Revisions: Date

CONSULTANTS:

VAMC, Salt Lake City, UT 84148

ARCHITECT/ENGINEERS:

VAMC Urgent Care Addition

2015-01-12

B.04

Office of

Construction and Facilities

Management

1490 S. Price Road, Suite 302, Chandler, AZ 85286 office: (480) 244-3355 www.engineeredwithlayton.com

F I N

A L

C

O N

S T

R U

C T

I O

N

D

O C

U M

E N

T S

SEAL:

324 S. State St., Suite 400

Salt Lake City, UT 84111

800-678-7077, 801-328-5151 fax: 801-328-5155 www.spectrum-engineers.com

2766 S. Main Street

Salt Lake City, Utah 84115 801.355.5656 bhb@bhbengineers.com

R O O M F I N I S H S C H E D U L E

JAMB DETAIL

SCALE: 3" = 1'-0" (HEAD SIMILAR)

CARD ACCESS DOOR TYPE SCHEDULE

DOOR

TYPE #

SYMBOL DESCRIPTION PROTECTED SIDE ELEVATION UNPROTECTED SIDE ELEVATION LOCK TYPE(S) DIVISION OF WORK AND COMMENTS

TYPE 1

HARDWARE GROUP:

SINGLE DOOR, 1 CARD

READER, (FREE EGRESS)

ELECTRIC STRIKE SECURITY CONTRACTOR PROVIDES:

CR, L/PS

HARDWARE CONTRACTOR PROVIDES:

ES, REX, CI

LOCK CONTROLLED BY:

CR

.75" C (TYP)

4SQ J-BOX

ABOVE ACC

CEILING

CONTACT

INDICATOR 1G

BOX IN FRAME

TO ACS

.75" C (TYP)

4SQ J-BOX

ABOVE ACC

CEILING

CARD READER

4SQ BOX W/ 1G

RING

ELECTRIC STRIKE 1G

BOX IN FRAME

J

J

J

#1

CR

SECURITY CONTRACTOR PROVIDES:

CR, L/PS

HARDWARE CONTRACTOR PROVIDES:

ML, L/PS, REX, RL

LOCK CONTROLLED BY:

CR, RL

ABBREVIATIONS

DBL = DOUBLE

DIR = DIRECTION

HDWR = HARDWARE

C = CONDUIT

4SQ = FOUR SQUARE

W/ = WITH

1G = 1 GANG

PWR = POWER

ACC = ACCESSIBLE

OCC = OCCUPANCY

TYP = TYPICAL

L/PS = LOCK POWER SUPPLY

CR = CARD READER

CI = DOOR CONTACT INDICATOR

EPT = ELECTRIC POWER TRANSFER

ES = ELECTRIC STRIKE

ED = EXIT DEVICE

ML = ELECTROMAGNETIC LOCK

KS = KEY SWITCH

ACS = ACCESS CONTROL SYSTEM

EL = ELECTRIC LOCKSET

MD = MOTION DETECTOR

TLC = TIME/SYSTEM LOCK CONTROL

ELC = EMERGENCY LOCK CONTROL

IDS = INTRUSION DETECTION SYSTEM

ADA = AUTO DOOR OPENER

REX = REQUEST TO EXIT

FA = FIRE ALARM SYSTEM

OFP = OBTAIN FROM PLANS

A/R = AS REQUIRED

AED = ACCESS EXIT DEVICE (SEE SECTION 87100)

AEL = ACCESS ELECTRIC LOCKSET (SEE SECTION 87100)

FH = FRAME HARNESS

DH = DOOR HARNESS

PROVIDE RACEWAY AND EQUIPMENT AS INDICATED FOR CARD ACCESS

DOOR TYPE INDICATED. REFER TO SECTION 281300 AND CARD ACCESS LOCK

CONTROL DETAILS FOR ADDITIONAL REQUIREMENTS.

PROVIDE CONCEALED .75" C TYPICAL FOR LINES SHOWN TO DEVICE BOXES

ON PROTECTED SIDE AND UNPROTECTED SIDE ELEVATIONS.

CONFIRM CORRECT CARD ACCESS DOOR RACEWAY, LOCK VOLTAGE, AND

EXIT SWITCH CURRENT RATING (2 AMPS MIN.) WITH DIV. 8 FURNISHED CARD

ACCESS DOOR HARDWARE PER DIV. 8 DOOR HARDWARE SPECIFICATIONS.

LOCATE CARD READER BOX AS INDICATED ON FLOOR PLANS. RACEWAY AND

BOXES BY DIV. 26. REFER TO 281300 FOR CARD ACCESS SYSTEM

REQUIREMENTS.

DOUBLE 4SQ J-BOX ON PROTECTED SIDE OF DOORWAY (SIDE OPPOSITE OF

CARD READER) ABOVE ACCESSIBLE CEILING OR IN OTHER ACCESSIBLE

LOCATION. PROVIDE COVER FOR J-BOX.

ELECTRIC LOCKING HARDWARE (MAG LOCKS, ELECTRIC STRIKES, POWER

TRANSFER HINGES, ETC.) BY DIV 8. REVIEW DOOR HARDWARE FURNISHED

AND VERIFY LOCK VOLTAGES AND OPERATIONAL FUNCTIONALITY OF LOCKS.

CONTACT ENGINEER WITH QUESTIONS OR CONCERNS.

4.

3.

1.

2.

NOTES

5.

6.

.75" C (TYP)

4SQ J-BOX

ABOVE ACC

CEILING

CARD READER

4SQ BOX W/ 1G

RING

J

TO ACS

SINGLE DOOR, 1 CARD

READER

(FREE EGRESS)

CR

#2

J

4SQ J-BOX

ABOVE ACC

CEILING

J

.75" C (TYP)

LOCK & CONTACT

INDICATOR 1G

BOX IN FRAME

EXIT MOTION

1G BOX

REMOTE

RELEASE

RL

HARDWARE GROUP:

HARDWARE GROUP:

TYPE 9

TYPE 10 SECURITY CONTRACTOR PROVIDES:

CR, L/PS

HARDWARE CONTRACTOR PROVIDES:

ML, L/PS, REX

LOCK CONTROLLED BY:

CR

.75" C (TYP)

4SQ J-BOX

ABOVE ACC

CEILING

CARD READER

4SQ BOX W/ 1G

RING

J

TO ACS

SINGLE DOOR, 1 CARD

READER

(FREE EGRESS)

CR

#3

J

4SQ J-BOX

ABOVE ACC

CEILING

J

.75" C (TYP)

LOCK & CONTACT

INDICATOR 1G

BOX IN FRAME

EXIT MOTION

1G BOX

TYPE 5

HARDWARE GROUP:

SINGLE DOOR, 1 CARD

READER, (FREE EGRESS)

ELECTRIC STRIKE SECURITY CONTRACTOR PROVIDES:

CR, L/PS

HARDWARE CONTRACTOR PROVIDES:

ES, REX, CI, PB

LOCK CONTROLLED BY:

CR, PB

.75" C (TYP)

4SQ J-BOX

ABOVE ACC

CEILING

CONTACT

INDICATOR 1G

BOX IN FRAME

TO ACS

.75" C (TYP)

4SQ J-BOX

ABOVE ACC

CEILING

CARD READER

4SQ BOX W/ 1G

RING

ELECTRIC STRIKE 1G

BOX IN FRAME

J

J

J

#4

CR

EXIT MOTION

1G BOX

PB

PUSH BUTTON

PB

Drawing Title

Approved: Project Director

Project Title

Date

Location

Checked

Building Number

Project Number

Drawing Number

Drawn

Dwg. of

Revisions: Date

CONSULTANTS:

VAMC, Salt Lake City, UT 84148

ARCHITECT/ENGINEERS:

VAMC Urgent Care Addition

2015-01-12

B.04

Office of

Construction and Facilities

Management

1490 S. Price Road, Suite 302, Chandler, AZ 85286 office: (480) 244-3355 www.engineeredwithlayton.com

F I N

A L

C

O N

S T

R U

C T

I O

N

D

O C

U M

E N

T S

SEAL:

324 S. State St., Suite 400

Salt Lake City, UT 84111

800-678-7077, 801-328-5151 fax: 801-328-5155 www.spectrum-engineers.com

2766 S. Main Street

Salt Lake City, Utah 84115 801.355.5656 bhb@bhbengineers.com

AD101
Sheets
AD101 - LEVEL 1 DEMOLITION PLAN
AD102
AD102A
AE100
AE101
AE101A
AE101B
AE101C
AE101D
AE102
AE103
AE141
AE141A
AE141B
AE141C
AE141D
AE161
AE201
AE202
AE301
AE302
AE303
AE304
AE305
AE451
AE452
AE453
AE454
AE455
AE456
AE501
AE502
AE510
AE530
AE540
AE550
AE551
AE560
AE561
AE570
AE571
AE572
AE581
AE582
AE601
AE602
AI101
AI501
AI601