36C25819B0025-003.pdf
PDF 11 MB Posted
- Solicitation number
- 36C25819B0025
About this file
36C25819B0025 S02 - ATTACHMENT 2 - 605-17-500 Architectural 100 Percent.pdf
View the file
Other files
Show all 41
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
ISOMETRIC VIEW (N.T.S.)
TWO PIECE UMBRELLA
SOLDERED
FIELD FABRICATED BASE
FLASHING, PER ROOFING
MANUFACTURER SPEC.,
ADHERE TO STL POST AND
SEAL AT EDGES
STL. POST
SOLDER
M
IN
2"SOLDER
/4
6" M
IN
TWO PIECE
UMBRELLA
GL
T/ SCREEN 41' - 2"
70" PANEL SCREEN
HSS COLUMN BEYOND
WHERE OCCURS, SEE
STRUCTURAL
STRUCTURAL COLUMN CAP
HSS STRUCTURAL MEMBER,
SEE STRUCTURAL
HSS STRUCTURAL MEMBER,
SEE STRUCTURAL
HSS COLUMN BEYOND
WHERE OCCURS, SEE
STRUCTURAL
HSS STRUCTURAL MEMBER,
SEE STRUCTURAL
35" PANEL SCREEN
COLUMN BRACKET
COLUMN CORNER BRACKET,
WHERE OCCURS
COLUMN CORNER BRACKET,
WHERE OCCURS
COLUMN BRACKET
COLUMN BRACKET
COLUMN CORNER BRACKET,
WHERE OCCURS
(E) CONCRETE
METAL DECK
(N) CONCRETE
METAL DECK PER
STRUCTURAL
(N) STIFFINER
PER STRUCTURAL
(E) BEAM - SEE
STRUCTURAL DWGS
(N) PLATE PER
STRUCTURAL
30' - 0"
HSS STRUCTURAL MEMBER,
SEE STRUCTURAL
ALL SIDES U.N.O.
1' - 0" TYP.
SBS MODIFIED BITUMINOUS
MEMBRANE ROOFING,
SINGLE-PLY ROOFING
MEMBRANE OVER
1/2" COVER BOARD
(N) RIGID INSULATION
BOARD
SS DRAWBAND
TWO PIECE UMBRELLA -18
GA GALV SHT METAL
(N) BASE FLASHING
(N) TAPERED RIGID
INSULATION FILL
SEALANT - REQUIRED
/2
T.O.S. ROOF
30' - 0"
D C A
T/ LOW PARAPET
32' - 6"
D.3 C.6 B
35" PANEL MECHANICAL SCREEN
70" PANEL MECHANICAL SCREEN
A301
TOP ROOF SCREEN
41'-3"
18' - 5 1/2" 7' - 10" 31' - 10"
58' - 1 1/2"
A.8
1C
AE115
1B
AE115
T.O.S. ROOF
30' - 0"
DCA
T/ LOW PARAPET
32' - 6"
C.6B
35" PANEL SCREEN
70" PANEL SCREEN
TOP ROOF SCREEN
41'-3"
58' - 1 1/2"
A.8
A301
T.O.S. ROOF
30' - 0"
4 5 6
T/ LOW PARAPET
32' - 6"
35" PANEL SCREEN
70" PANEL SCREEN
TOP ROOF SCREEN
41'-3"
75' - 10"
PRESSURE TREATED BLOCKING
SLOTTED SLIP CLIP
14 GA 8"X8" BENT MTL
PLATE ATTACHED TO
BLOCKING
EDGE OF SLAB FIRESTOPING
JOINT SYSTEM
2' - 3" V.I.F.
1' - 1 1/2" V.I.F.
V.I.F.
3"
(E) SURFACE MOUNTED
REGLET - PRESERVE
SEALANT - REPLACE AS
NEEDED
(E) CONCRETE
METAL DECK
(N) CONCRETE
METAL DECK PER
STRUCTURAL
(N) STIFFINER
PER STRUCTURAL
(E) BEAM - SEE
STRUCTURAL DWGS
(N) PLATE PER
STRUCTURAL
SBS MODIFIED BITUMINOUS
MEMBRANE ROOFING,
SINGLE-PLY ROOFING
MEMBRANE OVER
1/2" COVER BOARD
(N) RIGID INSULATION
BOARD
(N) SS
DRAWBAND
(N) TWO PIECE UMBRELLA
-18 GA GALV SHT METAL
(N) BASE FLASHING
(N) TAPERED RIGID
INSULATION FILL
(N) SEALANT - REQUIRED
15231 Laguna Canyon Road, Suite 200 Irvine, CA 92618
Tel: 949-417-7550 Fax: 949-585-9391
N
13220 Evening Creek Drive S Suite 115 San Diego, California 92128-4103 Ph: 858.668.0707 www.reidmiddleton.com Copyright 2019 Reid Middleton, Inc.
c
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Final Submittal
Office of Programs and Project
Management Jerry L.
Pettis VA Medical
Center U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
605-17-500
RENOVATION OF SURGICAL ONCOLOGY,
BLDG 31
VA LOMA LINDA HEALTHCARE SYSTEM
11201 BENTON STREET
LOMA LINDA, CA 92357
JC BP05-27-19
Project Director
Scale:
VA PG-18-1335% Submittal 09-22-17
65% Submittal
95% Submittal
01-31-18
03-22-19
05-03-19100% Submittal
EC PROJECT NO. 20170433
05-27-19Final Submittal
C R e v it L o c a l F ile s \V
A L o m a L in d a C
C A
C
E N
T R
A L b p e g a h i.
rv t /2
/2
:0
:4
A
M
As indicated
A301
EXTERIOR DETAILS
1 1/2" = 1'-0"4 FLASHING AT STEEL POST, TYP.
1 1/2" = 1'-0"1 MECHANICAL EQMT ROOF SCREEN
1/4" = 1'-0"13 MECHANICAL EQUIPMENT SCREEN EAST ELEVATION
1/4" = 1'-0"14 MECHANICAL EQUIPMENT SCREEN NORTH ELEVATION (SOUTH SIM.)
1/4" = 1'-0"15 MECHANICAL EQUIPMENT SCREEN WEST ELEVATION
1 1/2" = 1'-0"5 ROOF SCREEN @ PARAPET
Revisions: Date:
SEE FIN SCHED FOR APPLIED FIN SUCH AS CT, VINYL FABRIC, PANELING, ETC.
STANDARD STUD SIZE SHALL BE 3 5/8" 20 GA SSMA DES 362 S 137-33 UNO. NON-STANDARD STUD
SIZES ARE INDICATED AS FOLLOWS: FOR LEAD LINED PTN'S STANDARD STUD SIZE
SHALL BE 6" 20 GA SSMA 600 S 137-33.
STANDARD CMU SHALL BE 8" (NOM) THK UNO. NON-STANDARD CMU THK ARE INDICATED AS
FOLLOWS:
WHERE MFR'S HGT LIMITATIONS ARE EXCEEDED DUE TO FIELD CONDITIONS, USE HEAVIER
GAUGE STUDS IN ACCORDANCE W/ MFR'S RECOMMENDATIONS.
SEE FLOOR PLANS FOR WALL PARTITION LEGEND.
6"
2 G3LA
2 M3
1.
2.
3.
4.
5.
6"
PTN CHANGES
TYPE
M1
INDICATES PTN TYPE
6"
2 G3LA
FIRE RATING
• NUMBER OF HOURS
• IF NO NUMBER PTN
IS NON-RATED
• S - SMOKE PTN
STUD SIZE/THICKNESS
IF DIFFERENT FROM
STANDARD 3 5/8" STUD
OR 8" CMU
MATERIAL
G - GWB STUD PTN
F - FURRING W/GWB
M - CMU
S - SHAFT WALL
LEAD THICKNESS
THE NUMBER OF
1/16" OF LEAD
HEIGHT OF PTN
1 - UP TO CLG
2 - TO 6" ABV CLG
3 - TO STRUCTURE ABV
4 - LOW HT PTN
5 - UNDERSIDE OF
CEILING JOIST
SPECIAL ATTRIBUTE
A - ACOUSTICAL
L - LEAD LINED
B - GWB BOTH SIDES
@ SHAFT WALL
R - RESILIENT FURRING
NON-RATED PTN FIRE RATED OR ACOUS PTN
FURR @ PTN'S
PTN INTERSECTION
COL ENCL
FURR @ PTN'S
PTN INTERSECTION
COL ENCL
NON-RATED
PTN
FURR
PTN
NON-RATED
PTN'S
FURR
PTN
SPRAY
FPRF FURR
PTN
SPRAY
FPRF
FIRE SL
NON-RATED
PTN
RATED PTN (SEE PTN
SCHED FOR
CONFIGURATION)
IF DIM ALLOWS
RUN FIRE RATED
PTN PAST COL
ALTERNATE-BUTT
FIRE RATED GWB
INTO COL FPRF
ACOUS INS
WHERE SCHED
ACOUS INS
WHERE SCHED
FURR
PTN
RATED PTN (SEE
PTN SCHED FOR
CONFIGURATION)
NON-RATED PTN
DETAIL 'X'
1/2" BTWN STUDS
1/4" GWB CJ
DBL STUD
CRIPPLE STUD
DR FR BELOW
3" = 1'-0"
DOOR ELEVATION
NTS
'X'
LINE OF CLG
CRIPPLE STUDS
1/4" GWB CJ
DBL STUDS
HM DR FR
NOTES:
1. FOR ALL FURRING
TYPES TERMINATE
GWB 6" ABV FIN CLG UNO
FOR ALL FURRING TYPES
GWB TO EXTEND
TO STRUCTURE ABV
2. FOR EXT WALLS
ISOLATE MET FURR FROM
CONC OR MAS W/15 LB
BLDG PAPER
3. FOR STUD NOT FIXED
DIRECTLY BACK TO ADJ
MAS/CONC WALL BRACE
BACK TO WALL @ 4'-0" OC
OR EXTEND STUD TO
STRUCTURE ABV
4. FOR FURRING TYPE
TERMINATE GYB
AT UNDERSIDE OF CEILING
JOIST
SECTION
SECTION
PLAN
PLAN
SECTION
F2R
F3R
1.5" F3A
1.5" F2A
D F3
D F2
F3
F3A
F2
F2A
7/8" F3
7/8" F2
ADJACENT WALL TYPE
5/8" GWB ON HORIZ RES
FURR CHANNELS @ 2'-0" OC.
FURR & GWB TO UNDERSIDE
OF STRUCTURE, WHERE
REQUIRED
F2
F3
5/8" GWB ON Z-FURR CHANNELS
@ 2'-0" OC. W/ J-FURR RUNNERS
TOP & BOT
RIGID INS & GWB TO
UNDERSIDE OF STRUCTURE
5/8" GWB ADHERED DIRECTLY
TO WALL
MET STUD BRACE @
4'-0" OC VERT
5/8" GWB ON 3 5/8" MET
STUDS @ 1'-4" OC
SAFB @ F2A , F3A &
ONLY
5/8" GWB ON HORIZ 7/8" MET
FURR CHANNELS @ 2'-0" OC
VERT W/ MET FURR RUNNERS
TOP & BOT
F5
F5A F5A
SEE STRUCTURAL
SHEETS FOR
FASTENER FOR
DETAILS
J STOP BEAD EA SIDE
PERIM RELIEF @ WALLS
(PLAN VIEW)
CONTROL JT
(PLAN VIEW)
MET STUD
MET STUD EA SIDE OF CJ
COMPRESSIBLE FILLER
@ ACOUS PTN
CJ TRIM EA SIDE
SEAL BOTH SIDES W/ ACOUS
SL @ ACOUS & SMOKE PTN'S
/4
WALL
M A
X /2
G
A P
STRUCTURE ABV
20 GA RUNNER W/3" LEGS
HEAD DETAIL
PLAN DETAIL
POWDER ACTUATED FASTENERS
8" OC STAGGERED 1" EMBED
4 7/8"
ACOUS SL @ ACOUS PTN'S
& SMOKE PTN'S EA SIDE
J STOP BEAD EA SIDE
DETAIL @ FL
SEAL AROUND PENETRATING
DEVICES W/ACOUS SL @
ACOUS & SMOKE PTN'S AND
FDA COMPLIANT SEAL AT BSL
SUITE, TYP.
5/8" GB EA SIDE
3.5" BATT INSULATION
@ G3A
3 5/8" 20 GA SSMA 362 S
137-33 STUDS @ 16" OC,
OTHER STUDS INDICATED ON
PLANS G3
6"
SCHED BASE
MET RUNNER
ACOUS SL @ ACOUS PTNS & SMOKE
PTN'S EA SIDE AND FDA COMPLIANT
SEAL AT BSL SUITE, TYP.
/4
1" CLEAR BETWEEN TOP OF
STUDS & RUNNER
1 1/2" X 2" 19 GA CLIP
1 1/2" COLD ROLLED CHANNEL
BRIDGING
ATTACH CLIPS TO STUD &
BRIDGING W/FRAMING SCREWS
G3
G3A STC 49 SA-870717
STC 40 USG 860808
FL
SEE STRUCTURAL FOR
FASTENER DETAILS.
CEILING AS SCHEDULED
20 GA MET RUNNER
HEAD DETAIL
PLAN DETAIL
5 1/4"
3 5/8" 20G STUD BRCG DIAG
FROM PTN TO UNDERSIDE OF
STRUCTURE ABV @ 4'-0" OC
2"X2" 16GA CLIP ANGLE FIX TO
DIAG BRACE & HEAD RUNNER
W/ 4 #8-18 SM SCREWS
TERMINATE GWB 6" ABV FIN
CLG
DETAIL @ FL
SEAL AROUND PENETRATING
DEVICES W/ACOUS SL @
ACOUS & SMOKE PTN'S AND
FDA COMPLIANT SEAL AT BSL
SUITE, TYP.
5/8" GB EA SIDE
3.5" BATT INSULATION @
4" 20 GA SSMA 362 S 137-33
STUDS @ 16" OC, OTHER
STUDS INDICATED ON PLANS
G2A 6"
SCHED BASE
MET RUNNER
ACOUS SL @ ACOUS PTNS &
SMOKE PTN'S EA SIDE, FDA
COMPLIANT SEAL AT BSL SUITE,
TYP.
/4
SEE STRUCTURAL FOR
FASTENER DETAILS.
/2
C
L R
G2A
5/8" GWB
MET STUD
SCHED PTN
ALUMINUM CLOSURE
PIECE TO MATCH
WINDOW FRAME
SILICONE COATED
FOAM FILLER
ALTERNATE END
OF PTN DETAIL
C PTNL
L CASING BEAD
DOUBLE STUD @
END OF WALL
FACE OF WIN
STC 53
UNDERSIDE OF STRUCTURE
RUNNER W/3" LEGS
SCHED CLG
MET STUD BRCG @ 4'-0" OC TO
UNDERSIDE OF STRUCTURE -
MIN 2 UP TO 12'-0" HGT
CONT 4"X20 GA ATTACHMENT
PL OR 3/4" FRT PLWD PNL
LOCATED TO RECEIVE TOILET
PTN'S & SCREENS EA SIDE
PTN TYPE F3A EA SIDE
MET RUNNER
FLOOR
ACOUS SL EA SIDE
FIRE SAFING @ FLUTED DECK
1" CLEAR BETWEEN TOP OF
STUDS & RUNNER
ACOUS SL EA SIDE
SEE PLAN FOR DIM
GWB TYPE & # OF LAYERS
AS REQD BY PTN TYPE
M A
X
SAFB WHERE SCHED
3/4" CLEAR BETWEEN TOP
OF STUDS & RUNNER
16 GA Z CLIPS @ 24" OC MAX
SIZE TO CLR FPRF THK (PTN
MUST WITHSTAND A MIN OF
5 PSF LATERAL LOAD)
SPRAY SL MIN 1/8" THK @
RATED CONDITION ONLY
MIN WOOL BATTS 4 PCF
20 GA RUNNER W/3" LEGS
RATED PTN:
SHOWN UL HW D 0465
1 HR & 2 HR RATED
NON-RATED PTN:
SL @ SIDE OR SIDES
W/O CLG
ACOUS & SMOKE PTN'S:
SL EA SIDE W/ACOUS SL
GWB TYPE & # OF LAYERS
AS REQD BY PTN TYPE
M A
X
SAFB WHERE SCHED
3/4" CLEAR BETWEEN TOP
OF STUDS & RUNNER
16 GA Z CLIPS @ 24" OC MAX
SIZE TO CLR FPRF THK (PTN
MUST WITHSTAND A MIN OF
5 PSF LATERAL LOAD)
SPRAY SL MIN 1/8" THK @
RATED CONDITION ONLY
MIN WOOL BATTS 4 PCF
20 GA RUNNER W/3" LEGS
SPRAY SL MIN 1/8" THK @
RATED CONDITION ONLY
MW BATTS
PTN TYPE AS SCHED
RATED PTN:
SHOWN UL HW S 0069
1 HR & 2 HR RATED
NON-RATED PTN:
SL @ SIDE OR SIDES
W/O CLG
ACOUS & SMOKE PTN'S:
SL EA SIDE W/ACOUS SL
2" MIN
1" MIN
M A
X
/2
M
IN
EXPAND MET LATH SCREW
FIXED TO Z FURRING
STL Z FURRING SHANNELS
16 GA @ 24" OC MAX WELDED
TO STL BEAM
SPRAY FRPF TO COVER MET
LATH & Z FURRING W/SAME
THK AS FRPF TO STL BEAM
UL APPROVED FIRE STOP
ASSEMBLY HW D 0049 PARALLEL
AND HW D 0042 PERPENDICULAR
HEAD DETAIL
4 7/8"
DETAIL @ FLR
SEAL AROUND PENETRATING
DEVICES WITH ACOUSTICAL SL
3" SAFB @ 1 G3A
3 5/8" SSMA 362 S 137-33
STUDS @ 16" OC, OTHER
STUDS INDICATED ON PLANS
1 G3 6"
SCHED BASE
MET RUNNER
FIRE SL EA SIDE AND FDA
COMPLIANT SEALANT AT
BSL SUITE, TYP.
/4
STRUCTURE ABV (MET DECK)
FLR
SPRAY SL
MW BATT
RUNNER - MIN SSMA 362T 250-43
FOR STUDS FROM 12' TO 22' L
POWDER ACTUATED FASTENERS
8" OC STAGGERED 1" EMBED
1" CLEAR BETWEEN TOP OF
STUDS & RUNNER
1 1/2" X 2" 20 GA CLIP
1 1/2" COLD ROLLED CHANNEL
BRIDGING
ATTACH CLIPS TO STUD &
BRIDGING W/FRAMING SCREWS
5/8" TYPE X GWB EA SIDE
1 HR - UL DES U465
BOT OF RUNNER
C SCREWL
/4
1 HR - UL BW-S-0013
M A
X
M A
X
SEE STRUCTURAL FOR
FASTENER INFORMATION
CL
UNDERSIDE OF MET DECK
OR STRUCTURE
STL BM (SEE STR)
GWB FIRE RESISTANT BM
ENCLOSURE UL SYS N501
UL APPROVED FIRE
STOP SYS HW D 0049
RATED PTN
CL
UNDERSIDE OF MET DECK
OR STRUCTURE
UL APPROVED FIRE
STOP SYS HW D 0218
SPRAY FPRF
STL BM (SEE STR)
MET STUDS TO FRAME
AROUND BM
EDGE OF GWB
FIRE SL
15231 Laguna Canyon Road, Suite 200 Irvine, CA 92618
Tel: 949-417-7550 Fax: 949-585-9391
N
13220 Evening Creek Drive S Suite 115 San Diego, California 92128-4103 Ph: 858.668.0707 www.reidmiddleton.com Copyright 2019 Reid Middleton, Inc.
c
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Final Submittal
Office of Programs and Project
Management Jerry L.
Pettis VA Medical
Center U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
605-17-500
RENOVATION OF SURGICAL ONCOLOGY,
BLDG 31
VA LOMA LINDA HEALTHCARE SYSTEM
11201 BENTON STREET
LOMA LINDA, CA 92357
JC BP05-27-19
Project Director
Scale:
VA PG-18-1335% Submittal 09-22-17
65% Submittal
95% Submittal
01-31-18
03-22-19
05-03-19100% Submittal
EC PROJECT NO. 20170433
05-27-19Final Submittal
C R e v it L o c a l F ile s \V
A L o m a L in d a C
C A
C
E N
T R
A L b p e g a h i.
rv t /2
/2
:0
:5
A
M
As indicated
A302
PARTITION TYPES
SCALE: 3" = 1'-0"
PARTITION KEY
SCALE: 3/4" = 1'-0"
PARTITION CONTINUITY PLAN DIAGRAMS
SCALE: 3" = 1'-0"
TYP DETAIL OF GWB CJ @ DOOR FRAME
SCALE: 3" = 1'-0"
FURRING PARTITION TYPES F
SCALE: 3" = 1'-0"
TYP GWB PARTITION DETAILS - NON-RATED
SCALE: 3" = 1'-0"
PARTITION TYPE G3 - FULL HEIGHT
SCALE: 3" = 1'-0"
PARTITION TYPE G2 - NON-RATED INCOMBUSTIBLE
SCALE: 3" = 1'-0"
PARTITION CLOSURE - @ CURTAIN WALL
SCALE: 1 1/2" = 1'-0"
PIPE CHASE W/ ACOUSTICAL WALLS
SCALE: 3" = 1'-0"
GWB PARTITION ON CENTER LINE OR MINIMAL OFFSET OF STEEL FRAME
SCALE: 3" = 1'-0"
GWB PARTITION OFFSET OF CENTER LINE OF FPRF STEEL FRAME
SCALE: 3" = 1'-0"
1 hour FR partition
SCALE: 1 1/2" = 1'-0"
10A
RATED PTN ON CL OF UNPROTECTED BEAM - 1HR FIRE RATED
SCALE: 1 1/2" = 1'-0"
10B
RATED PTN PERP TO SPRAY FPRF STL BEAM
ASI #1 TBD
PARTITION AS
SCHEDULED
3/8" ALLOWANCE FOR
Z-CLIP AND CLEATS
1/2" BALTIC BIRCH
PLYWOOD BACKER
DECORATIVE PANEL
2 1/2" METAL STUDS
CORNER GUARD AS
SCHEDULED
5"
/8
/8
PARTITION AS
SCHEDULED
3/8" ALLOWANCE FOR
Z-CLIP AND CLEATS
1/2" BALTIC BIRCH
PLYWOOD BACKER
DECORATIVE PANEL
2 1/2" METAL STUDS
CORNER GUARD AS
SCHEDULED
5"
CORNER GUARD AS
SCHEDULED
THINSET CERAMIC
TILES, AS SCHEDULED
/8
/8
/8
DECORATIVE PANEL
.125 STAINLESS STEEL
STRIP TO COVER EDGE
OF PANEL WALL
DECORATIVE PANEL PRESSES ONTO A SOLID CORE
DOOR WITH CONSTRUCTION MASTIC. PER
MANUFACTURERS RECOMMENDATION
PARTITION AS
SCHEDULED
3/8" ALLOWANCE FOR
Z-CLIP AND CLEATS
1/2" BALTIC BIRCH
PLYWOOD BACKER
DECORATIVE PANEL
.125 STAINLESS STEEL
ANGLE TO COVER EDGE
OF PANEL WALL
SOLID CORE DOOR
PARTITION AS SCHEDULED
BACKING PLATE @ Z-CLIPS
1/2" BALTIC BIRCH
PLYWOOD BACKER
DECORATIVE PANEL
2 1/2" METAL STUDS
3/8" ALLOWANCE FOR Z-CLIP. Z-CLIP
TO RUN FULL LENGTH OF PANEL
WIDTH. MINIMUM (3) OF Z-CLIPS PER
PANEL. EXTREME TOP, BOTTOM AND
CENTER.
INSTALLER TO GLUE CLEATS
TO THE BACK OF THE PANEL
FINISH FLOOR
6" WALL BASE
2 3/8" 1/8"
PARTITION AS SCHEDULED
BACKING PLATE @ Z-CLIPS
DECORATIVE PANEL SYSTEM
2 1/2" METAL STUDS
Z-CLIP AND CLEATS
HANGER
WIRE
SCHEDULED
SUSPENDED
ACOUSTICAL
CEILING
METAL KICKER TO
STRUCTURE ABOVE @ 48"
O.C. WITH (3) - #10 SMS
EA FOR IN PLACE BRACING
1' - 0"
4" METAL STUDS
9'-0" AFF
8'-6" AFF
10'-0" AFF
EQ EQ
LIGHTING FIXTURE
SEE ELEC. DWGS
8" MAX.
2 3/8" 1/8"
REFER TO PLAN FOR
PARTITION TYPE
ACCESSIBLE
HARDWARE & LATCH
FIRE EXTINGUISHER
CABINET FIRE
EXTINGUISHER
BLOCKING, AS NEEDED
SECTION A
PLAN A
REFER TO PLAN FOR PARTITION TYPE
MTL CORNER BEAD, TYP
FIRE EXTINGUISHER CABINET
FIRE EXTINGUISHER
10" RO
VERIFY
/2
F I R E
E X T I N G U I S H E R
A F
F
T O
H
IG
H E
S T
H A
N D
L E
(E X
T
IN
G U
IS
H
E R
O R
C A
B
IN
E T
H A
N D
L E
ELEVTION A
11 1/2"
/8
1' - 0" 1' - 0"
C
(E) STEEL COLUMN
AND FIRE PROOFING
DECORATIVE WALL
SYSTEM
PARTITION AS
SCHEDULED
/4
/8
/8
1' - 0" 1' - 0"
B
(E) STEEL COLUMN
AND FIRE PTOOFING
NON RATED COLUMN
FURRING
/4
/4
A .F
.F
WALL AS SCHEDULED
3"
1 1/2" 1 1/2"
1 1/4" DIAMETER SS GRAB BAR
ATTACH TO BACKING W/
(3) #10 12 X 2 1/2" STAINLESS
STEEL SELF TAPPING SCREWS
PLATE- 3 1/4" DIA.
SPACER SLEEVE
3 (#10 SMS) 2 AT TOP
AND ONE AT BOTTOM
COVER PLATE
PROVIDE CONT 16 GA STUD
TRACK BACKING PER DETAIL 4/AE303
3 (310 SMS) 2 AT TOP
AND ONE AT BOTTOM
1" 1"
M A
X
/2
3"
15231 Laguna Canyon Road, Suite 200 Irvine, CA 92618
Tel: 949-417-7550 Fax: 949-585-9391
N
13220 Evening Creek Drive S Suite 115 San Diego, California 92128-4103 Ph: 858.668.0707 www.reidmiddleton.com Copyright 2019 Reid Middleton, Inc.
c
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Final Submittal
Office of Programs and Project
Management Jerry L.
Pettis VA Medical
Center U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
605-17-500
RENOVATION OF SURGICAL ONCOLOGY,
BLDG 31
VA LOMA LINDA HEALTHCARE SYSTEM
11201 BENTON STREET
LOMA LINDA, CA 92357
JC BP05-27-19
Project Director
Scale:
VA PG-18-1335% Submittal 09-22-17
65% Submittal
95% Submittal
01-31-18
03-22-19
05-03-19100% Submittal
EC PROJECT NO. 20170433
05-27-19Final Submittal
C R e v it L o c a l F ile s \V
A L o m a L in d a C
C A
C
E N
T R
A L b p e g a h i.
rv t /2
/2
:0
:4
A
M
As indicated
A303
FRAMING DETAILS
3" = 1'-0"4 END WALL @ WOOD ACCENT WALL
3" = 1'-0"7 END WALL @ WOOD ACCENT WALL
3" = 1'-0"5 DOOR JAMB @ WOOD ACCENT WALL
3" = 1'-0"1 BASE @ WOOD ACCENT WALL
3" = 1'-0"2 HEAD @ WOOD ACCENT WALL
1 1/2" = 1'-0"15 FIRE EXTINGUISHER CABINET DETAIL
1 1/2" = 1'-0"9 COLUMN @ WOOD ACCENT WALL
1 1/2" = 1'-0"6 COLUMN @ WAITING RM
3" = 1'-0"12 GRAB BAR ANCHORAGE
CAULK AT WALL
VERTICAL
SUPPORT OR
CABINET
(BEYOND)
F
IN
IS
H
W A
L L
FINISH FLOOR
2' - 1"
(O R
A S
I N
D
IC
A T
E D
O N
P L A
N
COUNTER: SOLID SURFACE
3/4" X 3 1/2" HDWD BACK CLEAT
(PROVIDE END CLEAT @
ADJOINING WALL). MOUNT
COUNTER TO BLKG
3/4" X 2 1/4" HDWD CLEAT @ EA
SUPPORT BRKT - PTD TO MATCH
WALL SURF
FULL PNL SUPPORT @ OPEN
END OF COUNTER. PLAM FIN
ON 3/4" PBD
ENDSPLASH @ ADJOINING WALL
ELEC / DATA DEVICE
BACKSPLASH: AS SPECIFIED
WALL BASE AS SPECIFIED
BACKING PLATE, TYP SEE
DETAIL 4/AE304 FOR
ADDITIONAL ANCHORAGE AND
BACKING REQUIREMENTS TYP.
CASEWORK W/ LAMINATED
FINISH OR SOLID SURFACE (@ WET)
COUNTERS PER SPECS
CONTINUOUS FRENCH CLEAT
BACK: 1/2" BIRCH
PLYWOOD
BACKING PLATE PER DETAIL 4/AE304
PARTITION TYPE
REFER TO FLOOR
PLAN FOR
BLOCKING
CONTINUOUS FRENCH CLEAT
CONT. 2x4 PRESSURE-
TREATED BLOCKING
16 GA TRACK
1/4" THK CASEWORK BACK SET
INTO 3/8" CONT. DADO GROOVE IN
CASEWORK SIDES, T&B
14 GA 3X3X CONT. BENT PL.
WITH (1) HILTI X-U POWDER
DRIVEN FASTENERS @ 8"
O.C. WITH 1 1/4" EMBED
ESR #2269
BACKING PLATE PER DETAIL 4/AE304
1/4" DIA. LAG SCREW
WITH 1" MIN EMBED @
12" O.C. TYP.
PARTITION TYPE
PLAN FOR
REFER TO FLOOR
RES BASE ON CONT SUB-BASE
CASEWORK FRONT
CASEWORK BOTTOM
CONT. 2x4 PRESSURE
TREATED WD BLOCKING
1/4" DIA. LAG SCREW WITH
1" MIN EMBED @ 12" O.C. TYP.
3"
14 GA 3X3X CONT. BENT PL. WITH (1) HILTI
X-U POWDER DRIVEN FASTENERS @ 8"
O.C. WITH 1 1/4" EMBED ESR #2269
/2
2' - 0"
FAUCET, SINK AND
ACCESSORIES PER
SPECIFICATIONS
ENDSPLASH AT ANY
ADJOINING WALLS, TYP.
1/8" QUIRK
PROFILE OF MIN
CLEARANCE REQD
FOR ACCESSIBILITY
PLAM SELF
EDGING @
ALL FOUR
EDGES OF
DWR'S & DR'S
3"
6" BASE (SEE
FINISH PLANS)
DR'S & FALSE DWR
FRONTS: PLAM ON
3/4" BIRCH PLYWD
8" MIN
MIN
3"
SSUR COUNTERTOP AND
INTRAGRAL 4"
BACKSPLASH
BACKSPLASH: AS
SPECIFIED
BACK: 1/2" BIRCH PLYWD
INS DRAIN AND HOT
WATER SUPPLY PIPING
SIDES OF BASE CAB:
3/4" BIRCH PLYWOOD
BACKING PLATE, TYP
SEE DETAIL 4/AE304 FOR
ADDITIONAL
ANCHORAGE AND
BACKING
REQUIREMENTS TYP.
C L R
A F
F /8
NOTE:
UNO, INT FIN ON ALL
EXPOSED SURF -
MELAMINE
CONTINUOUS
FRENCH CLEAT
NOTE:
AT CABS WITHOUT DOORS,
FIN INT OF CAB & SHELVES
W/ PLAM TO MATCH EXT
3"
2' - 1"
BACKSPLASH: PLAM
BACKING PLATE, TYP SEE DETAIL
4/AE304 FOR ADDITIONAL
ANCHORAGE AND BACKING
REQUIREMENTS TYP.
TOP AND BOTTOM
DRAWER SLIDE
P-LAM DOOR FRONT
PLAM SELF EDGING @ ALL FOUR
EDGES OF DRAWER FRONTS
DRAWER FRONTS: PLAM ON 3/4"
BIRCH PLYWD
RES BASE ON CONT SUB-BASE
/2
A304
3A
SIM
A304
SIM
A304
SIM
/2
TOP: PLASTIC LAMINATE
DWR SUBHEAD, BACK & SIDES:
PLAM ON 1/2" BIRCH PLYWD
DWR BOTTOM: THERMOSET
DECORATIVE OVERLAY ON 1/2"
BIRCH PLYWD
BACK: 1/2" BIRCH PLYWD
TOP, BOT & SIDES OF BASE CAB:
3/4" BIRCH PLYWOOD
A304
3B
SIM
CONTINUOUS FRENCH CLEAT
(3) #12 PAN HEAD SMS
TYPICAL AT EACH STUD AT
TYPE A1, A2 AND A3
BACKING PLATES
(3) FULL HEIGHT 16 GA STL STUDS
@ 16" OC, WHERE BACK PLATE
OCCURS, TYP-#8 PAN HEAD SMS
TYPICAL
6" X 1 1/4" X 16 GA STL TRACK, NOTCH
AROUND STUDS AND EXTRENDING
OVER 3 STUDS (MINIMUM)
1/8" MAX
1/8" MAX
NOTE:
1. PROVIDE BACKING PLATES AS INDICATED ON
THE DRAWINGS OR, WHERE NOT INDICATED,
ACCORDING TO THE FOLLOWING SCHEDULE:
2. COORDINATE LOCATION, LENGTH, HEIGHT AND
NUMBER OF BACKING PLATED REQUIRED WITH
ITHM TO BE MOUNTED.
3. FOR METHOD OF ATTACHMENT OF ITEM TO BE
MOUNTED, REFER TO THE APPLICABLE DETAIL
OR, IF NOT DETAILED, THE INSTRUCTIONS
PROVIDED BY THE MANUFACTURER.
4. SEE STRUCTURAL DRAWINGS FOR ADDITIONAL
INFORMATION.
TYPE AO BACKING PLATE
-NO BACKING REQUIRED FOR NON-STRUCTRUAL
SUPPORTING ITEMS SUCH AS PEEL AND STICK
HAND SANTIZER AND SOAP DISPENSERS LESS
THEN 5 LBS.
TYPE A1 BACKING PLATE:
-AT SMALL ITEMS (SUCH AS TOILET ACCESSORIES,
MIRRORS, CLOTHES HOOKS, DOOR STOPS ETC)
WHICH WEIGH OR SUPPORT WEIGHTS OF LESS
THAN 50 POUNDS.
TYPE A2 BACKING PLATE:
-AT ALL UPPER WALL-HUNG CABINETS
-AT ALL BASE CABINETS
-AT ALL FULL HEIGHT CABINETS
-AT ALL WALL-MOUNTED HANDRAILS,
GUARDRAILS, GRAB BARS, BUMPER RAILS, CRASH
RAILS
-AT WALL-MOUNTED ADJUSTABLE SHELVING
TYPE A3 BACKING PLATE:
-AT LAVATORY SINKS
NOTE:
REFER TO MILLWORK DETAILS FOR
CABINETS TO BE CONNECTED
M A
X
2' - 0"
ENDSPLASH AT ANY
ADJOINING WALLS, TYP.
PROFILE OF MIN
CLEARANCE REQD
FOR ACCESSIBILITY
TOP: SOLID SURFACE
BACKSPLASH: SOILD
SURFACE
UNDERMOUNT SINK
INSULATION KIT
TRUEBRO #102
WALL BASE AS
SPECIFIED
6" MAX.
1"
M
IN
8" MIN.
CUSTOM SUPPORT
BRACKET
1' - 1"
CASE WORK CLOSURE PANEL
PLAM ON 3/4" BIRCH PLYWD
PVC EDGE ON 4 SIDES OF SHELF
A L
IG
N
DOOR: PLAM ON 3/4" BIRCH PLYWD
/2
S E
E E
L E
V A
T
IO
N S
CLG AS SCHEDULED
HOLES DRILLED 1 1/4" OC TO
RECEIVE MOLDED SHELF CLIP
ADJUSTIBLE SHELF: NUMBER AS
REQUIRED
HOLES DRILLED 1 1/4" OC TO
RECEIVE MOLDED SHELF CLIP
NOTE:
AT CABS W/OUT DOORS, FINISH INT
OF CAB & SHELVES W/ PLAM TO
MATCH EXT
SCRIBE STRIP - PAINT BLACK
BACKING PLATE, TYP SEE DETAIL
4/AE304 FOR ADDITIONAL
ANCHORAGE AND BACKING
REQUIREMENTS TYP.
TOP AND BOTTOM
CONTINUOUS FRENCH CLEAT
1' - 3 3/4"
CASE WORK CLOSURE PANEL
PLAM ON 3/4" BIRCH PLYWD
PVC EDGE ON 4 SIDES OF SHELF
A L
IG
N
DOOR: PLAM ON 3/4" BIRCH PLYWD
/2
CLG AS SCHEDULED
HOLES DRILLED 1 1/4" OC TO
RECEIVE MOLDED SHELF CLIP
ADJUSTIBLE SHELF: NUMBER AS
REQUIRED
BOTTOM & SIDES OF BASE CAB:
3/4" BIRCH PLYWD
NOTE:
UNO, INT FIN ON ALL EXPOSED
SURF - NOTE: AT CABS WITHOUT
DOORS, FINISH INT OF CAB &
SHELVES W/ PLAM TO MATCH EXT
SCRIBE STRIP - PAINT BLACK
BACKING PLATE, TYP SEE
DETAIL 4/AE304 FOR ADDITIONAL
ANCHORAGE AND BACKING
REQUIREMENTS TYP.
TOP AND BOTTOM
C L E
A R
1' - 1"
PLAM ON 3/4" BIRCH PLYWD SIDE
PANEL, BOTH SIDES
SEE ELECTRICAL FOR MORE INFO
PLAM ON ALL EXPOSED SURFACES
OF BACK: 1/2" BIRCH PLYWD
CONTINUOUS FRENCH CLEAT
1/8" RADIUS
WHERE CABINET DOOR
OR FILLER PANEL
OCCURS
/2
1"
CAULK AT WALL
VERTICAL
SUPPORT OR
CABINET
(BEYOND)
F
IN
IS
H
W A
L L
FINISH FLOOR
2' - 1"
S
E A
T E
D H
E
IG
H T
L O
C A
T
IO
N S
COUNTER: SOLID SURFACE
PREFAB PENCIL DWR OR
KEYBOARD TRAY
PROVIDE 2X BLOCKING INSIDE
MTL. STUD AND ATTACH
BRACKET TO MTL. STUD W/ (3)
1/4"∅ A307 THROUGH BOLTS,
PRE-DRILL HOLE THROUGH
STUD AND BLOCKING, TYP.
ENDSPLASH @ ADJOINING WALL
ELEC / DATA DEVICE
BACKSPLASH: AS SPECIFIED
WALL BASE AS SPECIFIED
L O
C A
T
IO
N S
O N
L Y
S
T A
N D
IN
G
H E
IG
H
T
GROMMET FOR EA DEVICE
1/4" S.M.S. @ 12" O. C. (2 MIN.)
PRE MANUFACTURED FLUSH
MOUNTED COUNTERTOP
BRACKET AT 4'-0" O.C.
FIXED PANEL
3" 6
B A
S E
S E
E E
L E
V A
T
IO
N V
A R
IE
S
/2
"SCREW W/ CAP TO
MATCH CABINET
INTERIOR
WOOD BLOCKING
3/4" X 3 1/2" CONT
WD CLEAT
ADJUSTABLE SHELVES,
SEE ELEVATION FOR
COUNT
WALL SHEATING
SCHEDULED BASE
2'-0"
ALTERNATE
SLOPED TOP
15231 Laguna Canyon Road, Suite 200 Irvine, CA 92618
Tel: 949-417-7550 Fax: 949-585-9391
N
13220 Evening Creek Drive S Suite 115 San Diego, California 92128-4103 Ph: 858.668.0707 www.reidmiddleton.com Copyright 2019 Reid Middleton, Inc.
c
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Final Submittal
Office of Programs and Project
Management Jerry L.
Pettis VA Medical
Center U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
605-17-500
RENOVATION OF SURGICAL ONCOLOGY,
BLDG 31
VA LOMA LINDA HEALTHCARE SYSTEM
11201 BENTON STREET
LOMA LINDA, CA 92357
JC BP05-27-19
Project Director
Scale:
VA PG-18-1335% Submittal 09-22-17
65% Submittal
95% Submittal
01-31-18
03-22-19
05-03-19100% Submittal
EC PROJECT NO. 20170433
05-27-19Final Submittal
C R e v it L o c a l F ile s \V
A L o m a L in d a C
C A
C
E N
T R
A L b p e g a h i.
rv t /2
/2
:0
:0
A
M
As indicated
A304
MILLWORK DETAILS
1 1/2" = 1'-0"6 OPEN COUNTER - STANDING HEIGHT
3" = 1'-0"3A TYPICAL BACK SPLASH
3" = 1'-0"2 CABINET ANCHORAGE BASE REAR
3" = 1'-0"1
CABINET ANCHOR DETAIL @ CABINET
BASE FRONT
1 1/2" = 1'-0"8
FOWARD REACH ACCESSIBLE SINK
CABINET
1 1/2" = 1'-0"5
MILLWORK BASE CABINET W/ DRAWERS
& PLASTIC LAMINATE TOP
1 : 14 TYPICAL BACKING DETAIL
1 1/2" = 1'-0"11 ACCESSIBLE VANITY
1 1/2" = 1'-0"7 UPPER WALL CABINET
1 1/2" = 1'-0"10 MICROWAVE WALL CABINET
3" = 1'-0"3B TYPICAL EDGE DETAIL
1 1/2" = 1'-0"9 OPEN COUNTER - SEATED HEIGHT
1/2" = 1'-0"12 FULL HEIGHT CABINET
HOLLOW METAL FRAME
GYP BOARD - THICKNESS
AND NUMBER OF
LAYERS PER PARTITION
TYPES SCHEDULE
SEALANT EA SIDE(TYP.)
JAMB ANCHOR, TYP
BOXED 3 5/8" 20 GA SSMA
362 S 137-33 STUDS
THROAT VARIES
HOLLOW METAL FRAME
NOTE:
PROVIDE MFR'S RECOMMENDED
HEAD REINFORCING FOR DOORS
OVER 3' - 0" WIDE. PROVIDE
MINIMUM DOUBLE CHANNEL.
GYP BOARD - THICKNESS
AND NUMBER OF
LAYERS PER PARTITION
TYPES SCHEDULE
SEALANT (TYP.)
CLEARANCE PER DOOR
FRAME MANUFACTURER
TYPICAL TRACK
DR THK +3/16" VARIES DR THK +3/16"
ACTUAL PTN THK +1"
/8
1/2" TYP.
20 GA METAL "U" STRAP
@ 24" O.C.
ACTUAL PTN THK
H A
R D
W A
R E
T Y
P
IC
A L
/4
E
L E
C T
R
IF
IE
D
B
HEAD DETAIL (SECT)
A
JAMB DETAIL (PLAN)
O P
N G
S
IZ
E
HOLLOW METAL FRAME
GYP BOARD - THICKNESS
AND NUMBER OF
LAYERS PER PARTITION
TYPES SCHEDULE
SEALANT EA SIDE(TYP.)
JAMB ANCHOR, TYP
BOXED 3 5/8" 20 GA SSMA
362 S 137-33 STUDS
THROAT VARIES
HOLLOW METAL FRAME
GYP BOARD - THICKNESS
AND NUMBER OF
LAYERS PER PARTITION
TYPES SCHEDULE
SEALANT (TYP.)
CLEARANCE PER DOOR
FRAME MANUFACTURER
20 GA RUNNER
DR THK +3/16" VARIES DR THK +3/16"
ACTUAL PTN THK +1"
/8
1/2" TYP.
20 GA METAL "U" STRAP
@ 24" O.C.
ACTUAL PTN THK
H A
R D
W A
R E
T Y
P
IC
A L
/4
E
L E
C T
R
IF
IE
D
B
HEAD DETAIL (SECT)
A
JAMB DETAIL (PLAN)
O P
N G
S
IZ
E
L CLIP BEYOND TO CONNECT
TO JAMB TYPICAL TRACK
BOXED 3 5/8" 20 GA SSMA
362 S 137-33 STUDS
20 GA RUNNER
ACTUAL PTN THK
1" 1" 3'-10 1/2" FRAME OPENING 1" 1"
4'-0 1/2" ROUGH OPENING STUD FRAMING
1 1/2"
/8
LINE OF FRAME ABOVE
/8
/8
P E
R P
L A
N
P A
R T
IT
IO
N
EPDM GASKET
BOTH SIDES
VALANCE & END
CAP ABOVE
BACK TO BACK
LADDER PULLS
ROOM SIDE
OUTSIDE
/4
EDGE GASKET
SILL GUIDE
LINE OF VALANCE ABOVE2 1/4"
4'-1 1/4" DOOR LEAF
3/4" 7'-8 5/8" CARRIAGE TRACK 3/4"
7'-10" VALLANCE
DOOR SHOWN IN
OPEN POSITION
PULL BACKSET
2 1/2" 2"
4 1/2"
SILICONE LIP
SEAL
3'-6" CLEAR OPENING
LINE OF VALANCE ABOVE
4'-1 1/4" DOOR LEAF
VALANCE & END
CAP ABOVE
A
JAMB @ PULL SIDE (DOOR SHOWN IN CLOSED POSITION)
B
AA BB
JAMB @ PULL SIDE (DOOR SHOWN IN OPEN POSITION) JAMB @ SILL GUIDE (DOOR SHOWN IN OPEN POSITION)
JAMB @ SILL GUIDE (DOOR SHOWN IN CLOSED POSITION)
STILE POCKET
LINE OF DOOR
FRAME
BOTTOM TRACK
SILL GUIDE
ANCHOR
/8
FINISH FLOOR
ROOM SIDEOUTSIDE
ROOM SIDEOUTSIDE
2 7/8"
PER PLAN
PARTITION 7/8"
EPDM GASKET
BOTH SIDES
CARRAGE TRACK
6' -1
1/
2" A
F F
C
LE
A R
O P
E N
IN
G
6' -1
3/
4" D
O O
R L
E A
F
/8
1 3/4"
#14 x 2 1/2" HHSDS
@ 12" O.C. MAX
BOXED HEADER
BACKING FOR SUPPORT
TRACK AS REQUIRED.
SLOPED VALANCE
WITH END CAPS
A
FLUSH SLIDER @ DOOR HEAD OPENING
B
FLUSH SLIDER HEAD @ WALL FRAMING
4 1/2"
4 1/2"
3/8" 2 1/4"
/4
O .F
.H S
T D
R .O
.H S
T D
RECESSED TRACK
LEVELED IN 1/4"
GROUTING
CLEAN ROOM
HORIZONTAL
BEVELED GLASS
STOP SYSTEM (TYP)
1/4" STANDARD
MOTION / PRESENCE
SENSORS
/8
S T
D H
T
/4
A
CLEAN ROOM DOOR @ SILL
B
MUTINS @ CLEAN ROOM DOOR
CLEAN ROOM DOOR HEAD
@ WALL FRAMING
COVER SIDE
BREAKOUT SIDE
FINISH FLOOR
C
CLEAN ROOM DOOR @ OPENING
/2
BACKING AS
REQUIRED FOR
DOOR TRACK
CLEAN ROOM
HORIZONTAL
BEVELED GLASS
STOP SYSTEM (TYP)
1/4" STANDARD
CLEAN ROOM
HORIZONTAL
BEVELED GLASS
STOP SYSTEM (TYP)
1/4" STANDARD
WALL
JAMB
BEYOND
WALL
JAMB
BEYOND
WALL
JAMB
BEYOND
EXTERIOR SIDE INTERIOR SIDE
EXTERIOR SIDE INTERIOR SIDE
D
3' - 6" OPENING WIDTH
3' - 8 5/8" ACTIVE LEAF WIDTH
/2
1 3/4"
COVER SIDE
BREAKOUT SIDE
3' - 2 3/8" CLEAR DOOR OPENING
PIVOT POINT
GUIDE TRACK
CLEAN ROON NON-SHEDDING
WEATHER STRIPPING
LEFT HAND SHOWN (R.H.S. OPPOSITE)
7' - 6 1/4" OVERALL FRAM WIDTH
EXTERIOR SIDE
INTERIOR SIDE
LINE OF FRAME ABOVE
CLEAN ROON VERTICAL
GLASS STOP SYSTEM, TYP.
1/4" STANDARD
15231 Laguna Canyon Road, Suite 200 Irvine, CA 92618
Tel: 949-417-7550 Fax: 949-585-9391
N
13220 Evening Creek Drive S Suite 115 San Diego, California 92128-4103 Ph: 858.668.0707 www.reidmiddleton.com Copyright 2019 Reid Middleton, Inc.
c
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Final Submittal
Office of Programs and Project
Management Jerry L.
Pettis VA Medical
Center U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
605-17-500
RENOVATION OF SURGICAL ONCOLOGY,
BLDG 31
VA LOMA LINDA HEALTHCARE SYSTEM
11201 BENTON STREET
LOMA LINDA, CA 92357
JC BP05-27-19
Project Director
Scale:
VA PG-18-1335% Submittal 09-22-17
65% Submittal
95% Submittal
01-31-18
03-22-19
05-03-19100% Submittal
EC PROJECT NO. 20170433
05-27-19Final Submittal
C R e v it L o c a l F ile s \V
A L o m a L in d a C
C A
C
E N
T R
A L b p e g a h i.
rv t /2
/2
:0
:0
A
M
3" = 1'-0"
A305
DOORS AND WINDOWS
3" = 1'-0"1 HM DOOR FRAME IN GWB PARTITION
3" = 1'-0"4
HM DOOR HEAD & JAMB OF OPENING
OVER 3'-6" WIDE
3" = 1'-0"10 FLUSH SLIDER JAMBS
3" = 1'-0"8 FLUSH SLIDER @ DOOR BOTTOM
3" = 1'-0"11 FLUSH SLIDER @ DOOR HEAD
3" = 1'-0"13 CLEAN ROOM SLIDER HEAD / SILL
3" = 1'-0"15 CLEAN ROOM SLIDER JAMBS
SUSPENDED CEILING SYSTEMS - - SECTION 803.9 AND SECTION
2506.2, 2016 CBC
- ASTM C-633 AND SECTION
13.5.6, ASCE-7-05
SUSPENDED CEILING SYSTEMS SHALL BE DESIGNED TO RESIST A LATERAL FORCE
OF 20% OF THE CEILING ASSEMBLY AND ANY LOADS TRIBUTARY TO THE SYSTEM
FOR PURPOSES OF DETERMINING THE LATERAL FORCE. A MINIMUM WEIGHT OF 5
POUNDS PER SQUARE FOOT SHALL BE USED.
WHEN THE CEILING LOADS DO NOT EXCEED 5 POUNDS PER SQUARE FOOT AND
WHERE PARTITIONS ARE NOT CONNECTED TO THE CEILING SYSTEM. THE
FOLLOWING BRACING SYSTEM MAY BE EMPLOYED.
A. LATERAL SUPPORT MAY BE PROVIDED BY FOUR WIRES OF MAXIMUM NO. 12
GAUGE SPLAYED IN FOUR DIRECTIONS 90 DEGREES APART, AND CONNECTED TO
THE MAIN RUNNER WITHIN 2" OF THE CROSS RUNNER AND TO THE STRUCTURE
ABOVE AT AN ANGLE NOT EXCEEDING 45 DEGREES FROM THE PLANE OF THE
CEILING. THESE LATERAL SUPPORT POINTS SHALL BE PLACED 12'-0" ON CENTER IN
EACH DIRECTIONS, WITHHELD FIRST POINT WITHIN 6'-0" FROM EACH WALL.
B. ALLOWANCE SHALL BE MADE FOR LATERAL MOVEMENT OF THE SYSTEM. MAIN
RUNNERS AND CROSS RUNNERS MAT BE ATTACHED AT TWO ADJACENT WALLS
WITH CLEARANCE BETWEEN THE WALL AND THE RUNNERS MAINTAINED AT THE
OTHER TOW WALLS.
C. VERTICAL SUPPORT SHALL BE PROVIDED AS REQUIRED IN UBC STANDARD
WITH THE ADDED REQUIREMENT THAT DISCONTINUOUS ENDS OF CROSS RUNNERS
AND MAIN RUNNERS SHALL BE VERTICALLY SUPPORTED WITHIN 8" OF SUCH
DISCONTINUITIES AS MAY OCCUR WHEN THE CEILING IS DISRUPTED BY A WALL.
D. LIGHTING FIXTURES AND AIR DIFFUSERS SHALL BE SUPPORTED DIRECTLY BY
WIRES TO THE STRUCTURE ABOVE.
EXCEPTION:
SECTION 25.213 - LIGHTING FIXTURES.
INTERMEDIATE OF HEAVY DUTY CEILING SYSTEMS AS DEFINED IN SECTION 47.1802
SHALL BE USED FOR THE SUPPORT OF LIGHT FIXTURES.
ALL LIGHTING FIXTURES SHALL BE POSITIVELY ATTACHED TO THE SUSPENDED
CEILING SYSTEMS. THE ATTACHMENT DEVICE SHALL HAVE A CAPACITY OF 100% OF
THE LIGHTING FIXTURES WEIGHT ACTING IN ANY DIRECTION.
WHEN INTERMEDIATE SYSTEMS ARE USED, NO 12 GAUGE HANGERS SHALL BE
ATTACHED TO THE GRID MEMBERS WITHIN 3" OF EACH CORNER OF EACH FIXTURE.
TANDEM FIXTURES MAY USE COMMON WIRES.
WHEN HEAVY DUTY SYSTEMS ARE USED, SUPPLEMENTAL HANGERS ARE NOT
REQUIRED IF A 48 INCH MODULAR HANGER PATTERN IS FOLLOWED. WHEN CROSS
RUNNERS ARE USED WITHOUT SUPPLEMENTAL HANGERS TO SUPPORT LIGHTINGS
FIXTURES, THESES CROSS RUNNERS SHALL PROVIDE THE SAME CARRYING
CAPACITY AS THE MAIN RUNNERS.
LIGHTING FIXTURES WEIGHING LESS THAN 56 POUNDS (24.5 KG) SHALL HAVE, IN
ADDITION TO THE REQUIREMENTS ABOVE, TWO NO. 12 GAUGE HANGERS
CONNECTED FROM THE FIXTURE HOUSING TO THE STRUC TRUE ABOVE. THESE
WIRES MAY BE SLACK.
LIGHTING FIXTURES WEIGHING 56 POUNDS (25.4 KG) OR MORE SHALL BE
SUPPORTED DIRECTLY FROM THE STRUCTURE ABOVE BY APPROVE HANGARS.
PENDANT HUNG LIGHTING FIXTURES SHALL BE SUPPORTED DIRECTLY FROM THE
STRUCTURE ABOVE WITH NO. 9 GAUGE WIRE OR APPROVED ALTERNATE SUPPORT
WITHOUT USING THE CEILING SYSTEM FOR DIRECT SUPPORT.
AIR DIFFUSERS WHICH WEIGH NO MORE THAN 20 POUNDS AND WHICH RECEIVE NO
TRIBUTARY LOADING FORM DUCTWORK MAY BE POSITIVELY ATTACHED TO AND
SUPPORTED BY THE CEILING.
WHERE THE CEILING SYSTEM PROVIDES LATERAL SUPPORT FOR NON-WEIGHT
BEARING PARTITIONS, IT HALL BE DESIGNED FOR THE SPECIFIES LATERAL FORCES
IN ACCORDANCE WITH THE UBC STANDARDS.
OTHER METHODS MAY BE USED PROVIDED THEY ARE SUBSTANTIATED BY DESIGN
CALCULATIONS. THE APPROVED BUILDING PLANS SHALL IDENTIFY ALL ELEMENTS
AND SHOW ALL DETAILS OF THE PROPOSED ASSEMBLY.
RIGID VERTICAL SUPPORT, AS SHOWN IN THE SECTION, SHALL BE FASTENED TO
THE MAIN RUNNER AND SHALL EXTENDED TO THE STRUCTURAL MEMBERS
SUPPORTING THE ROOF OR FLOOR ABOVE. THE STRUT SHALL BE ADEQUATE TO
RESIST THE VERTICAL COMPONENT INDUCED BY THE BRACING WIRE, AND SHALL
HAVE AN L/R RATION OF LESS THAN 200. THESE RESTRAINT POINTS SHALL BE
PLACED AT 12'-0" ON CENTER IN BOTH DIRECTIONS WITH THE FIRST POINT WITHIN
6'-0" FROM EACH WALL.
COMPRESSION PIPE STRUT SIZE
SCHEDULE (BASED ON L/R LESS THAN 200)
SIZE
1/2" X 22 GAUGE
1/4" X 22 GAUGE
3/4" X 22 GAUGE
1" X 20 GAUGE
1 1/4" X 20 GAUGE
1 1/2" X 20 GAUGE
2" X 20 GAUGE
2 1/2" X18 GAUGE
3" X 16 GAUGE
3 1/2" X 16 GAUGE
MAX. HEIGHT:
3'-0" 4'-0" 4'-0" 6'-0" 7'-0" 8'-6" 11'-6" 14'-6" 17'-3" 23'-3"
NOTE:
ALL 24"X48" CEILING LIGHT FIXURES AND
24"X24" HVAC AIR REGISTER SHALL BE
SUPPORTED BY A MINIMUM OF TWO 12
GAUGE WIRE HANGERS AT OPPOSITE
CORNERS. CEILING SYSTEM SHALL NOT
SUPPORT OTHER ITEMS.
MAIN RUNNER
CROSS TEE
12 GA VERTICAL HANGER WIRES
COMPRESSIOIN STRUT AT EA.
GROUP OF SPLAYED BRACING
WIRES. SEE DETAIL 8/A306.
D E
G . M
A X
D E G
. M A X
12 GA SPLAYED BRACE
WIRES 4 TYP.
2"
MAX
2x2 OR 2x4 DIVIDED TILE
2 X 4 LIGHT FIXTUREE
Q
E Q
EQ EQ
SPRINKLER HEAD, DOWN
LIGHT, OR CLG. MTD ITEMS
DIFFUSER OR GRILLE, OR
2 x 2 LIGHT FIXTURE
E Q
E Q
1' - 0" 2' - 0" 1' - 0"
2x4 CEILING
2 X 4 LIGHT FIXTUREE
Q
E Q
EQ EQ
DIFFUSER OR GRILLE,
OR 2 X 2 LIGHT FIXTURE
E Q
E Q
EQ EQ
E Q
E Q
SPRINKLER HEAD, DOWN
LIGHT, OR CLG. MTD ITEMS
1' - 0" 1' - 0" 1' - 0" 1' - 0"
MTL STUD
COMPRESSION STRUT
2-#12 S.M.S @ EA.
COMPRESSION STRUT.
LAY-IN ACOUSTIC
CLG. & GRID.
T-BAR MAIN RUNNER
ACT
SEE RCP
ATTACH W/ #12 S.M.S.
@ 18" O.C.
STRUT HEIGHT
(FT)
STRUT
0' - 7'
10'
12'
1 5/8" X 20 GA.
2 - 1 5/8" X 20 GA.
2 - 2 1/2" X 20 GA.
CROSS TEE
MAIN RUNNER
VERTICAL HANGER
WIRE AT 4'-0" O.C. W/
3 TIGHT TRUNS IN 1
1/2" AT BOTH ENDS,
COMPRESSION STRUT @
12'-0" O.C. EACH WAY
12GA. SPLAYED BRACE WIRES
SPACED 12'-0" X 12'-0" MAX
AND WITHIN 4'-0" OF WALLS
ATTACH W/ 4 TIGHT TURNS IN
1-1/2" AT BOTH ENDS.
M A
X
45 DEG
M A X
45 DEG
12 GAUGE WIRE SPLAYED IN
FOUR DIRECTIONS 90 DEGREES
APART AT 12'-0" EACH WAY.
WALL
A306
A306
A306
A307
6" MAX
1/2" MIN.1/2" MIN.
#10 SMS @ EA 20GA
MIN WALL STUD
(24" OC MAX)
HANGER WIRES
FURRING
CHANNEL
#10 SMS @ EA
MAIN RUNNER
1"x2"x24GA CONT
ANGLE, TYP
/2
M
IN
SADDLE TIES
PER
NO CONNECTION
BETWEEN ANGLE
AND FURRING
CHANNEL
AT FREE SIDE
MIN
1" CLR
4" MAX
6" MAX
NOTE: FOR CONN. TO
WALL, SEE ATTACHED
JOINT.
MAIN RUNNER
FURRING
CHANNEL
#10 SMS @ EA
MAIN RUNNER
1"x2"x24GA CONT
ANGLE, TYP
#10 SMS @ EA 20 GA MIN
WALL STUD (24" OC MAX)
/2
M
IN
3/4" MIN3/4" MIN
6" MAX
1" MIN.
ATTACHED JOINT FREE JOINT
ATTACHED JOINT FREE JOINT
HANGER
WIRE
SADDLE TIE
PER
6" MAX
MIN
1" CLR
NO CONNECTION
BETWEEN ANGLE
AND FURRING
CHANNEL
AT FREE SIDE
NOTE: FOR CONN. TO WALL.
SEE ATTACHED JOINT .
NOTES: 1. PERIMETER WALLS SHALL BE DESIGNED TO CARRY TRIBUTARY LATERAL FORCES
PER TABLE BELOW. RDP TO VERFIY. RDP TO SPECIFY CONNECTION OF BACKING TO STUDS
1" MIN
REFER TO STRUC. DWGS FOR
CONNECTION TO STRUCTURE
.0
M A
XTYP.
1/2"
1/2" MAX. UNO
4 TURNS @ BRACE WIRES
TYP. @ EACH END
#12 GA. WIRE ASTM A641 WITH
CLASS, 1 COATING
M
AX
1 1/2"
REFER TO STRUC. DWGS
FOR CONNECTION TO
STRUCTURE
1/2" MAX. UNO
3 TURNS @ HANGER WIRE
TYP. @ EACH END
#12 GA. WIRE ASTM
A641 WITH CLASS 1
COATING
/2
T
Y P
M A
X
HANGER WIRE
BRACING WIRE
(2) 12 GA. SLACK WIRE
HANGERS FOR DEVICES
THAT WEIGH LESS THAN 56
LBS ( HEAVY DUTY GRID
SYSTEM REQUIRED), PLACE
ON DIAGONAL CORNERS.
EXCEPTION: 4'x4' FIXTURES
SHALL HAVE (4) TAUT
HANGERS @ CORNERS
2 #8 S.M.S EA.SIDE
RECESSED
LIGHT FIXTURE,
REFER TO
ELECTRICAL
SUSPENDED LAY-IN CEILING
HEAVY DUTY SYSTEM
WITH SPLAY WIRE
CL.
WITHOUT SPLAY WIRE
WALL VARIES
5/8" TYPE "X" GYP. BD.
WITH CASING BEAD
HANGER WIRE
MAIN RUNNER OR
CROSS TEE.
WALL TRIM
#12 GA. SEISMIC
SPLAY WIRES
MAIN RUNNER OR
CROSS TEE.
WALL TRIM
POP RIVET
MIN.
2"
MIN.
2"
3/4" CLEAR, TYP. 45°
8" MAX. 8" MAX. CL.
3/4" CLEAR, TYP.
A B
O V
E C
E
IL
IN
G
M
IN
HANGER WIRE
MAIN RUNNER OR
CROSS TEE
METAL KICKER TO
STRUCTURE ABOVE @ 48"
O.C. WITH (3) - #10 SMS
EA FOR IN PLACE BRACING
9'-0" AFF
8" MAX.
SCHEDULED CEILING
METAL BEAD
5/8" TYPE "X" GYP. BD.
#12 SEISMIC SPLAY
WIRES @ 96 SF.,
WHERE OCCURS
MOLD WI/ #6 x 1 1/4" SELF
TAPPING SCREWS @ EA.
STUD.
NOTE: WHERE MOLDING
COMES IN CONTACT W/ ALUM.
PLACE 20 GA. PVC SHEETING
BETWEEN & USE "S" STEEL
SCREWS OR CADMIUM
PLATED SCREWS.
2"
3/4"
HANGER WIRE
MAIN RUNNER OR
CROSS TEE
9'-0" AFF
8" MAX.
SCHEDULED
CEILING
METAL BEAD
5/8" TYPE
"X" GYP. BD.
#12 SEISMIC SPLAY
WIRES @ 96 SF.,
WHERE OCCURS
2"
3/4"
A B
O V
E C
E
IL
IL
IN
G
M
IN
METAL KICKER TO
STRUCTURE ABOVE @ 48"
O.C. WITH (3) - #10 SMS
EA FOR IN PLACE BRACING
MOLD WI/ #6 x 1 1/4" SELF
TAPPING SCREWS @ EA.
STUD.
NOTE: WHERE MOLDING
COMES IN CONTACT W/ ALUM.
PLACE 20 GA. PVC SHEETING
BETWEEN & USE "S" STEEL
SCREWS OR CADMIUM
PLATED SCREWS.
1' - 0"
METAL STUD AT 16" O.C.
15231 Laguna Canyon Road, Suite 200 Irvine, CA 92618
Tel: 949-417-7550 Fax: 949-585-9391
N
13220 Evening Creek Drive S Suite 115 San Diego, California 92128-4103 Ph: 858.668.0707 www.reidmiddleton.com Copyright 2019 Reid Middleton, Inc.
c
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Final Submittal
Office of Programs and Project
Management Jerry L.
Pettis VA Medical
Center U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
605-17-500
RENOVATION OF SURGICAL ONCOLOGY,
BLDG 31
VA LOMA LINDA HEALTHCARE SYSTEM
11201 BENTON STREET
LOMA LINDA, CA 92357
JC BP05-27-19
Project Director
Scale:
VA PG-18-1335% Submittal 09-22-17
65% Submittal
95% Submittal
01-31-18
03-22-19
05-03-19100% Submittal
EC PROJECT NO. 20170433
05-27-19Final Submittal
C R e v it L o c a l F ile s \V
A L o m a L in d a C
C A
C
E N
T R
A L b p e g a h i.
rv t /2
/2
:0
:1
A
M
As indicated
A306
CEILING DETAILS
3/8" = 1'-0"2 SUSPENED LAY-IN CEILING NOTES
1" = 1'-0"4 COMPRESSION STRUT
1/2" = 1'-0"5 TYPICAL CEILING TILE LAYOUTS
3" = 1'-0"8 TYPICAL COMPRESSION STRUT
1" = 1'-0"7 TYPICAL SUSPENDED LAY-IN CEILING
1 1/2" = 1'-0"14 CEILING PERIMETER
3" = 1'-0"11
HANGER AND BRACING WIRE
CONNECTIONS
3" = 1'-0"
SUSPENDED CEILING - LIGHT FIXTURE
SUPPORT
3" = 1'-0"
LAY-IN CEILING
3" = 1'-0"
BULKHEAD OPENING
3" = 1'-0"
BULKHEAD OPENING
2"
MA
X
MA
X
2"
COMPRESSION STRUT AT EA.
GROUP OF SPLAYED BRACING
WIRES, FOR ATTACHMENT
8GA. VERT HANGER WIRE AT 4'-0" O.C.
MAXIMUM. 6" MAXIMUM FROM END OF
COLD ROLLED CHANNEL
7/8" HAT CHANNEL
GYP. BD. SCREWED 12" O.C.
1 1/2" COLD ROLLED CHANNEL
45 DEG. MAX
45 DEG. MAX
12GA. SPLAYED BRACE
WIRES 4 TYP
1. CONSTRUCTION, WORKMANSHIP AND MATERIAL SHALL CONFORM TO THE 2013 CALIFORNIA
BUILDING STANDARDS CODE (CBSC 2013).
2. THE CONTRACTOR SHALL NOTIFY OSHPD AND THE REGISTERED DESIGN PROFESSIONAL (RDP) IN RESPONSIBLE CHARGE WHERE A CONFLICT OR DISCREPANCY OCCURS BETWEEN THE CONSTRUCTION DRAWINGS AND ANY OTHER PORTION OF THE CONSTRUCTION DOCUMENTS, FIELD CONDITIONS, OR
WHERE ANY CONDITIONS ARISE NOT COVERED BY THESE DOCUMENTS WHEREIN WORK WILL NOT
COMPLY WITH CODE REQUIREMENTS.
3. THE INTENT OF THE DRAWINGS AND SPECIFICATIONS IS TO CONSTRUCT THE HOSPITAL BUILDING IN ACCORDANCE WITH THE CALIFORNIA BUILDING STANDARD CODE, 2013 (CBSC 2013). SHOULD ANY
CONDITION DEVELOP NOT COVERED BY THE APPROVED CONSTRUCTION DOCUMENTS WHEREIN THE
WORK WILL NOT COMPLY WITH CBSC 2013, A CHANGE ORDER DETAILING AND SPECIFYING THE
REQUIRED WORK SHALL BE SUBMITTED TO AND APPROVED BY OSHPD BEFORE PROCEEDING WITH THE
WORK.
4. GALVANIZED METAL STUDS, TRACKS AND SHEET STEEL SHALL CONFORM TO ASTM A653-11 MATERIAL, OR OTHER EQUIVALENT ASTM LISTED MATERIALS IN SECTION A2.1 OF THE AISI SI00-07/S2-10; NORTH AMERICAN SPECIFICATION FOR THE DESIGN OF COLD-FORMED STEEL STRUCTURAL MEMBERS WITH SUPPLEMENT 2, DATED 2010, WITH A MINIMUM YIELD STRENGTH OF 33 KSI FOR 43 MIL (18 GAGE) AND
LIGHTER AND MINIMUM YIELD STRENGTH OF 50 KSI FOR HEAVIER GAGES.
METAL STUDS AND TRACKS SHALL BE OF SIZE, THICKNESS AND SECTION PROPERTIES SHOWN ON TABLES 1-1, 1-2 AND 1-3 OF THE AISI MANUAL, COLD-FORMED STEEL DESIGN, 2008 EDITION. THE RDP IN
RESPONSIBLE CHARGE SHALL OBTAIN OSHPD APPROVAL FOR ANY SUBSTITUTIONS.
5. ELECTRICAL METALLIC TUBE (EMT) SHALL BE ANSI C80.3/UL 797 CARBON STEEL WITH G90 GALVANIZING. EMT SHALL HAVE MINIMUM YIELD STRENGTH OF (Fy = ) 30 KSI AND MINIMUM ULTIMATE STRENGTH OF (Fu = ) 48 KSI.
6. THESE OPD REFER TO FASTENER TYPE AND SIZE BUT DO NOT SPECIFY OR ENDORSE A SPECIFIC MANUFACTURER. THE RDP IN RESPONSIBLE CHARGE SHALL SELECT A MANUFACTURER AND SELECTED FASTENER CAPACITIES SHALL MATCH OR EXCEED THE STRENGTHS LISTED HEREIN. THE FOLLOWING
REQUIREMENTS SHALL ALSO BE MET:
a. SHEET METAL SCREWS SHALL COMPLY WITH ASTM C 1513-10, ASME B18.6.4-98 (R2005) AND ICC-ES AC 118 AND ALLOWABLE STRENGTH SHALL BE BASED ON INFORMATION PROVIDED IN CG1.31 AND CG1.32.
PENETRATION OF SCREWS THROUGH JOINED MATERIAL SHALL NOT BE LESS THAN THREE EXPOSED
THREADS.
b. WELDING SHALL BE IN ACCORDANCE WITH AWS D1.3 USING E60XX SERIES ELECTRODES. FIELD WELDING SHALL HAVE SPECIAL INSPECTION IN ACCORDANCE WITH 2013 CBC SECTION 1705A.2.
c. POST- INSTALLED ANCHORS (E.G. EXPANSION ANCHORS, SCREW ANCHORS AND POWER ACTUATED FASTENERS) SHALL HAVE SPECIAL INSPECTION AND TESTING IN ACCORDANCE WITH THE 2013 CBC SECTIONS 1705A.3 & 1913A.7. FOR QUALIFICATION, DESIGN AND USE OF POST-INSTALLED ANCHORS IN CONCRETE SEE THE 2013 CBC SECTIONS 1616A.1.19 AND 1908A.1.1. LISTING OF CURRENT ICC-ES EVALUATION REPORTS (OR REPORTS FROM OTHER TESTING AGENCIES ACCEPTABLE TO OSHPD) SHALL
BE REQUIRED FOR FASTENER USED.
d. POWER-ACTUATED FASTENERS (PAF), POWDER DRIVEN FASTENERS (PDF), POWER DRIVEN PINS (PDP) AND SHOT PINS ALL REPRESENT THE SAME FASTENER AND WILL HEREAFTER BE REFERRED TO AS POWER ACTUATED FASTENERS (PAF). PAF'S SHALL SATISFY THE CURRENT AC70-ACCEPTANCE CRITERIA FOR FASTENERS POWER-DRIVEN INTO CONCRETE, STEEL AND MASONRY ELEMENTS AND THE 2013 CBC SECTIONS 1908A.1.1. LISTING OF CURRENT ICC ES EVALUATION REPORTS (OR REPORTS FROM OTHER TESTING AGENCIES ACCEPTABLE TO OSHPD) SHALL BE REQUIRED FOR FASTENERS USED.
e. FOR PAF INSTALLED IN STEEL THE FASTENER PENETRATION SHALL HAVE THE ENTIRE POINTED END OF THE FASTENER DRIVEN THROUGH THE STEEL MEMBER, EXCEPT AS NOTED IN CURRENT REPORTS
FROM TESTING AGENCIES ACCEPTABLE TO OSHPD.
7. DESIGN CRITERIA
a. BUILDING CODE: 2013 CALIFORNIA BUILDING CODE (2013 CBC), ASCE 7-10, AISI S100-07/S2-10, AND ASTM C754-11. FOR LOAD COMBINATIONS, ALLOWABLE STRESS DESIGN SHALL BE IN ACCORDANCE WITH
2013 CBC SECTION 1605A.3.1.
b. FASTENER CAPACITIES TABLES WERE DEVELOPED BASED ON ICC REPORTS BY SEVERAL
MANUFACTURERS.
c. THE DESIGN ASSUMES THAT BUILDING ELEMENTS AND SUPPORTS, TO WHICH THE COMPONENTS ADDRESSED IN THIS DOCUMENT ARE ANCHORED, HAVE SUFFICIENT CAPACITY TO CARRY THE LOADS
IMPOSED BY THE COMPONENTS IN COMBINATION WITH ALL OTHER LOADS. EVALUATION OF THE
CAPACITY OF THESE SUPPORTING BUILDING ELEMENTS IS BEYOND THE SCOPE OF THE OPD.
d. THIS OPD IS LIMITED TO CEILING ASSEMBLIES HAVING MAXIMUM DEAD WEIGHT OF 4 PSF, INCLUDING LIGHTING FIXTURES (LUMINERIES) AND MECHANICAL SERVICES, EACH WEIGHING LESS THAN 56 LBS AND ATTACHED TO CEILING FRAMING SYSTEM. HEAVIER SYSTEM AND THOSE SUPPORTING LATERAL FORCES FROM PARTITION WALLS ARE OUTSIDE THE SCOPE OF THIS OPD AND WILL REQUIRE PROJECT
SPECIFIC DESIGN.
8. THE RDP IN RESPONSIBLE CHARGE SHALL VERIFY THE FIRE RESISTENCE AND ACOUSTICAL RATINGS
FOR ALL CEILING ASSEMBLIES.
9. "CEILING WIRE" SHALL CONFORM WITH GALVANIZED SOFT ANNEALED MILD STEEL WIRE AS DEFINED
IN ASTM A641 (CLASS 1 COATING) WITH 70 KSI MINIMUM TENSILE STRENGTH:
a. FOUR (4) TWISTS OF WIRE WITHIN 1.5" DEVELOPS THE ALLOWABLE LOAD FOR THE WIRE.
b. THREE (3) TWISTS WITHIN 3" MAY BE USED TO DEVELOP THE MAXIMUM 50% OF ALLOWABLE LOAD.
10. SUSPENSION SYSTEM COMPONENTS SHALL COMPLY WITH ASTM C754:
a. MAIN RUNNNERS SHALL CONSIST OF 16 GAGE 1-1/2” COLD ROLLED U-CHANNEL 150U050-54 SPACED AT 4'-0” OC MAX. MAIN RUNNERS SHALL BE SUPPORTED BY HANGER WIRES AT 4'-0” OC MAX AND WITHIN
6” FROM EA END.
b. FURRING CHANNEL SHALL CONSIST OF 25 GAGE 7/8” (HAT) FURRING CHANNELS (087F125-18) at 2'-0” OC MAX. FURRING CHANNELS SHALL BE SADDLE TIED TO MAIN RUNNERS WITH 16 GAGE TIE WIRE OR A
DOUBLE STRAND OF 18 GAGE TIE WIRE.
c. MAIN RUNNERS SHALL BE SPLICED BY LAPPING IN ACCORDANCE WITH CG2.31.
d. FURRING CHANNELS SHALL BE SPLICED BY LAPPING IN ACCORDANCE WITH CG2.31.
e. MAIN RUNNERS AND FURRING CHANNELS ALONG WITH THEIR SPLICES, INTERSECTION CONNECTORS, AND EXPANSION DEVICES SHALL BE DESIGNED AND CONSTRUCTED TO CARRY A MEAN
ULTIMATE TEST LOAD OF NOT LESS THAN 270 LBS. IN COMPRESSION & TENSION.
f. HANGER AND BRACING WIRES SHALL BE #12 GAGE (0.106" DIAMETER), SOFT ANNEALED, AND GALVANIZED STEEL WIRES WITH CLASS 1 COATING. THEY MAY BE USED FOR UP TO AND INCLUDING 4'-0"x 4'-0" GRID SPACING ALONG AND ATTACHED TO MAIN RUNNERS. SPLICES ARE NOT PERMITTED IN
ANY HANGER WIRE.
g. WIRE HANGERS SHALL BE SADDLE-TIED AROUND MAIN RUNNERS SO AS TO PREVENT TURNING OR
TWISTING OF THE MEMBER.
11. SUSPENSION SYSTEM INSTALLATION SHALL COMPLY WITH ASTM C754:
a. CEILING GRID MEMBERS SHALL BE ATTACHED TO TWO (2) ADJACENT WALLS. MAIN RUNNERS AND FURRING CHANNEL SHALL BE AT LEAST 1 INCH CLEAR OF OTHER WALL AND FURRING SHALL BE AT LEAST 3/4” CLEAR OF OTHER WALL. IF WALLS RUN DIAGONAL TO THE CEILING GRID SYSTEM RUNNERS, ONE END OF MAIN RUNNER AND FURRING SHOULD BE FREE WITH STANDARD CLEARANCES.
b. THE WIDTH OF THE PERIMETER SUPPORTING CLOSURE ANGLE SHALL BE NOT LESS THAN TWO (2) INCHES. USE OF ANGLES WITH SMALLER WIDTHS IN CONJUNCTION WITH PERIMETER CLIPS SHALL REQUIRE AN ALTERNATE METHOD OF COMPLIANCE WITH ADEQUATE JUSTIFICATION AND ARE OUTSIDE
THE SCOPE OF THIS OPD.
12. EXPANSION JOINTS, SEISMIC SEPARATIONS, AND PENETRATIONS:
a. EXPANSION JOINTS SHALL BE PROVIDED IN THE CEILING AT INTERSECTIONS OF CORRIDORS AND
AT JUNCTIONS OF CORRIDORS WITH LOBBIES OR OTHER SIMILAR AREAS.
b. FOR CEILING AREAS EXCEEDING 2500 SQUARE FEET, A SEISMIC SEPARATION JOINT SHALL BE
PROVIDED TO DIVIDE THE CEILING INTO AREAS NOT EXCEEDING 2500 SQ. FT.
c. PENETRATIONS THROUGH THE CEILING FOR SPRINKLER HEADS AND OTHER SIMILAR DEVICES THAT ARE NOT INTEGRALLY TIED TO THE CEILING SYSTEM IN THE LATERAL DIRECTION SHALL HAVE A TWO (2) INCH OVERSIZED RING, SLEEVE OR ADAPTER THROUGH THE CEILING TILE TO ALLOW FREE MOVEMENT OF ONE (1) INCH IN ALL HORIZONTAL DIRECTIONS. A FLEXIBLE SPRINKLER HOSE FITTING THAT CAN ACCOMMODATE ONE (1) INCH OF CEILING MOVEMENT SHALL BE PERMITTED TO BE USED IN LIEU OF THE OVERSIZED RING, SLEEVE OR ADAPTER. SUCH FLEXIBLE SPRINKLER HOSE SHALL BE ADEQUATELY SUPPORTED FROM SOFFIT SO AS NOT TO EXCEED THE MAXIMUM TRIBUTARY WEIGHT OF THE CEILING.
13. LATERAL FORCE BRACING:
LATERAL FORCE BRACING IS REQUIRED IN ACCORDANCE WITH THIS SECTION FOR ALL
CEILING AREAS, UON.
EXCEPTION: LATERAL FORCE BRACING MAY BE OMITTED FOR SUSPENDED ACOUSTICAL
CEILING SYSTEMS WITH A CEILING AREA OF 144 SQ. FT. OR LESS, WHEN PERIMETER SUPPORT ARE
PROVIDED AND PERIMETER WALLS ARE DESIGNED TO CARRY THE CEILING LATERAL FORCES.
a. PROVIDE LATERAL-FORCE BRACING ASSEMBLIES CONSISTING OF A STRUT AND FOUR (4) #12 GAGE
BRACING WIRES ORIENTED 90 DEGREES FROM EACH OTHER.
b. LATERAL-FORCE BRACING ASSEMBLIES SHALL BE SPACED IN ACCORDANCE WITH CG2.20 THROUGH CG2.22 AND CG2.30 FROM EACH WALL AND AT THE EDGES OF ANY CHANGE OF ELEVATION OF THE
CEILING.
c. THE SLOPE OF BRACING WIRES MAY BE FROM 10 TO 45 DEGREES BUT MAY NOT EXCEED 45
DEGREES FROM THE PLANE OF THE CEILING AND WIRES SHALL BE TAUT.
d. STRUTS SHALL BE ADEQUATE TO RESIST THE VERTICAL COMPONENT INDUCED BY THE BRACING
WIRES, AND SHALL NOT BE MORE THAN 1 (HORIZONTAL) IN 6 (VERTICAL) OUT OF PLUMB.
10° TO 45° FROM
HORIZONTAL, TYP.
12 GA VERTICAL HANGERS AT
4'-0" O.C. EACH WAY AT MAIN
RUNNER WITH MINIMUM (3)
TIGHT TURNS IN 3" AT BOTH
ENDS OF WIRE, SEE
SADDLE -TIED FURRING
CHANNEL TO MAIN RUNNERS
WITH (2) STRANDS OF 18GA
WIRE OR (1) STRAND OF 16GA
WIRE, SEE
12GA BRACING WIRE WITH
MINIMUM 4 TIGHT TURNS IN
1-1/2" AT BOTH ENDS OF WIRE,
TYP (4) TOTAL AT EA STRUT,
SEE
STRUT PER
MAIN RUNNER
150U050-54 @ 4'-0" OC
5/8" GYPSUM BOARD
PERPENDICULAR TO
FURRING
FURRING CHANNEL
087F125-18 @ 24" OC
ATTACH GYP BOARD TO FURRING
WITH ASTM C1002 TYPE S
SCREWS WITH CORROSION
RESISTANT TREATMENT @12" OC
MAX
NOTES:
1. SEE GENERAL NOTES
2. STRUTS SHALL NOT REPLACE HANGER WIRES.
3. FOR CONDITIONS AT CORRIDOR SEE DRAWINGS
4. FOR MAIN RUNNER AND FURRING CHANNEL SPLICE CONNECTIONS
6 MIN
2'-0" T
YP
4'-0" TYP
A307
A307
A306
A307
NOTE: PRE ENGINEERED
SOFFIT FRAMING SYSTEMS
SUCH AS ARMSTRONG "DGS"
ARE ACCEPTABLE
#12 GAGE HANGER
WIRES (3) TIGHT
TURNS WITHIN 3"
MAIN RUNNER
SADDLE TIE HAS DOUBLE
LOOP AT SUPPORT
WHEN MULTIPLE SADDLE TIES
ARE REQUIRED THEY SHALL
ALTERNATE BACK AND FORTH
TO PREVENT TWISITNG
FURRING CHANNEL
MAIN RUNNER
#16 GAGE WIRE OR
DOUBLE STRAND OF
#18 GAGE WIRE
SADDLE TIE AT
MAIN RUNNER TO
HANGER WIRE
SADDLE TIE AT
FURRING RUNNER
TO MAIN RUNNER
HANGER WIRE
(2) SLACK SAFETY
WIRES TO STRUCTURE
SADDLE TIES
PER
MAIN RUNNER
FURRING CHANNEL
(4) #8 SMS INTO
FURRING CHANNELS
GYP BOARD
SURFACE MOUNTED FIXTURE
MAXIMUM WEIGHT = 56#
STRUT BEYOND
FURRING
CHANNEL
HANGER WIRE
BRACE WIRE, TYP.
4 TURNS IN 1 1/2" @ EA END
OF BRACE WIRE, TYP.
MAIN RUNNER
GYP BOARD
STRUT SCHEDULE
L L < 5'-0"_
5'-0" < L < 8'-0"
STRUT
250T125-33
400S137-33SIDE VIEW
METAL STUDS STRUT
PER SCHEDULE
3/8" DIA EXPANSION ANCHOR, SEE
HANGER WIRE
MAIN RUNNER
BRACE WIRE, SEE
4 TURNS IN
1 1/2" @ EA END
OF BRACE
WIRE, TYP.
#8 SMS TO PREVENT
SLIPPAGE OF BRACE
WIRES PARALLEL TO
MAIN RUNNER
3" MAX 2" MAX
(2) #10 SMS
GYP BOARD
FURRING CHANNEL
"L
S E
E S
C H
E D
U L E
(2) 12 GA SLACK SAFETY HANGER
WIRE AT DIAGONALLY OPPOSITE
CORNERS ANCHORED TO
STRUCTURE ABOVE PER
HANGER WIRE
SADDLE TIES
RECESSED LIGHT FIXTURE
MAX WT=56#
PROVIDE (1) OR MORE
150U050-54 AS REQUIRED.
SEE GENERAL NOTE #15B
SUPPORT BY FURRING
CHANNEL IS NOT PERMITTED
MAIN RUNNER
GYPSUM BOARD
8" MAX
FURRING CHANNEL
ADDITIONAL FURRINGN CHANNEL
AT FIXTURE AS REQUIRED
CLIP FLANGE & BEND
BACK TO FORM "L" CLIP
(2) #10 SMS ATTACH TO
WEB OF MAIN RUNNER,
TYP EA END.
SUPPLEMENTAL 150U050-54
MAIN RUNNER
NOTE: IF THE MAIN RUNNER IS CUT DUE TO FIXTURES, RDP SHALL SPECIFIY ADDITIONAL HANGER
WIRES AND/OR BRACING WIRES, AS REQUIRED TO MAINTAIN STRUCTURAL INTEGRITY
A
DETAIL
NTS
A
GYP. BOARD FURRING CHANNEL
WIRE HANGER
RUNNER (FRAMING)
CHANNELS
2-LAYERS OF 5/8"
TYPE 'X' GYP. BD.
PLASTIC GOMMIT DOOR
DRYWALL CASING
BEADS TYP.
TACK-WELD AS
REQUIRED
1 1/2" X 1 1/2" X 1 1/2"
16 GA. ANGLE CONN.
@ RUNNER W/ 2 #12 SMS
15231 Laguna Canyon Road, Suite 200 Irvine, CA 92618
Tel: 949-417-7550 Fax: 949-585-9391
N
13220 Evening Creek Drive S Suite 115 San Diego, California 92128-4103 Ph: 858.668.0707 www.reidmiddleton.com Copyright 2019 Reid Middleton, Inc.
c
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Final Submittal
Office of Programs and Project
Management Jerry L.
Pettis VA Medical
Center U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
605-17-500
RENOVATION OF SURGICAL ONCOLOGY,
BLDG 31
VA LOMA LINDA HEALTHCARE SYSTEM
11201 BENTON STREET
LOMA LINDA, CA 92357
JC BP05-27-19
Project Director
Scale:
VA PG-18-1335% Submittal 09-22-17
65% Submittal
95% Submittal
01-31-18
03-22-19
05-03-19100% Submittal
EC PROJECT NO. 20170433
05-27-19Final Submittal
C R e v it L o c a l F ile s \V
A L o m a L in d a C
C A
C
E N
T R
A L b p e g a h i.
rv t /2
/2
:0
:2
A
M
As indicated
A307
CEILING DETAILS
1" = 1'-0"4 TYPICAL SUSPENDED GYP. BD. CEILING
3/8" = 1'-0"5
SUSPENDED CEILING BRACING
ASSEMBLY
1" = 1'-0"7 SADDLE TIE DETAILS
3" = 1'-0"8 SURFACE MOUNTED FIXTURE
1 1/2" = 1'-0"6
STRUT & BRACING WIRE ASSEMBLY -
METAL STUD TYPE STRUT
1 1/2" = 1'-0"9 RECESSED LIGHT FIXTURE
3" = 1'-0"10 CEILING ACCESS PANEL
INDICATOR
LIGHT BAR
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it.