e f c,d d a,b j b a b j,k k h, i h i e,f c g a
2HA-6
2HX-1
OS
OS
OS
OS
OSOS
A4 A4 A4 A4
A4A4
A4E A4E A4E A4E
A4EA4E
A4E
OS
g
J
J J
J
J
J J
J
D
C
A
D.3
C.6
B
SOILED UTILITY
2C-123
EXAM 13
2C-121
EXAM 12
2C-119
EXAM 11
2C-117
BREAK ROOM
2C-115
EXAM 10
2C-113
EXAM 9
2C-111
EXAM 8
2C-109
EXAM 7
2C-107
EMS CLOSET
2C-102
EXAM 14
2C-112
EXAM 14
PATIENT TOILET(M)
2C-110
PATIENT TOILET(F)
2C-108
STAFF WOMEN'S TOILET
2C-106
STAFF MEN'S TOILET
2C-104
ELEVATOR AND WAITING
2B-100
IT
IT-2
ELEC
EL-2
SOILED UTILITY ROOM
2A-108
ROOF ACCESS
2A-107
SHARED OFFICE
2A-109
WHEELCHAIR ALCOVE
2A-103
UNISEX RESTROOM
2A-102
OFFICE PHARMACY
2C-128
CONFERENCE ROOM
2C-130
CHIEF OFFICE PHARMACY
2C-126
PHYSICIAN WORKROOM
2C-124
CORRIDOR
C2-2
CORRIDOR
C2-1
ELEV
OPEN TO BELOW
SHARED
STAIR
SCOPE OF WORK
LOCKERS
2C-100
HD ANTE ROOM
2C-120
DONNING ROOM
2C-114
NON-HD ANTE ROOM
2C-116
NON HD COMPOUNDING
2C-118
WORK AREA
2C-125
EXISTING ACT
EXISTING ACT
SUB WAITING
2B-101
HD COMPOUNDING
2C-122
K
D
C
A
D.3
C.2
B.4
A.6
C.6
B
K
1/4" = 1'-0"1 SECOND FLOOR PARTIAL LIGHTING PLAN AREA A
SECOND FLOOR PARTIAL LIGHTING
PLAN AREA A
E-102
SHEET NOTES
1 PROVIDE 24V CEILING MOUNTED OCCUPANCY SENSOR
AND POWER PACKS. SEE DETAIL 1 ON SHEET E-501.
2 PROVIDE WALL MOUNTED OCCUPANCY SENSOR.
SEE DETAIL 2 ON SHEET E-501.
3 INDIRECT TO MATCH EXISTING. CONNECT TO EXISTING CIRCUIT.
4 RELOCATED FROM "CHIEF OFFICE", CONNECT LIGHT AND SWITCH
TO EXISTING CIRCUIT.
5 RELOCATED FROM EXAM 14, CONNECT LIGHT AND SWITCH TO
EXISTING CIRCUIT.
E-401
1 TYP
GENERAL NOTES
A. SEE DETAIL 1 ON DWG. E-502 FOR CONDUIT EXPANSION JOINT CROSSING DETAIL.
B. SEE DETAIL 2 ON DWG. E-502 FOR CONDUIT TRAPEZE MOUNTING DETAIL.
C. SEE DETAIL 3 ON DWG. E-502 FOR FLOOR SLAB PENETRATION DETAIL.
D. SEE FIXTURE SCHEDULE ON DWG. E-700 FOR LIGHTING FIXTURE
MOUNTING DETAILS.
2nd FLOOR PROJECT BOUNDARY.
(NO WORK OUTSIDE THE BOUNDARY)
1 ASI #1 08/26/2015
N
13220 Evening Creek Drive S Suite 115
San Diego, California 92128-4103
Ph: 858.668.0707 www.reidmiddleton.com
Copyright 2019 Reid Middleton, Inc.
c
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Final Submittal Office of Programs and Project Management Jerry L.
Pettis VA Medical Center U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
605-17-500
RENOVATION OF SURGICAL ONCOLOGY,
BLDG 31
VA LOMA LINDA HEALTHCARE SYSTEM
11201 BENTON STREET
LOMA LINDA, CA 92357
N. SHERER M. PEREA05-27-19
Project Director
VA PG-18-13
C U s e r s e p e n a D e s k t o p E
D r i v e R e v i t
V
A
D e s i g n
R e n o v a t e
S u r g i c a l R
M V
A
R e n o
O n c o l o g y
B l d g
S
T R
U E
P r v t
A
M
Revisions: Date:
35% Submittal 09-22-17 65% Submittal 01-31-18 95% Submittal 03-22-19 100% Submittal 05-03-19
LOPEZ ENGINEERING, INC.
PROFESSIONAL CONSULTING ENGINEERS
4295 Gesner St. Suite 2C
San Diego, CA 92117
Tel (619) 275-5658
Fax (619) 275-1929 www.LopezEngineering.com
4700 Lincoln Rd. NE
Albuquerque, NM 87109
Tel (505) 342-6333
Fax (505) 342-6334
BA
Final Submittal 05-27-19 Amendment No. 02 08-20-19
AutoCAD SHX Text
KEYPLAN