This is a technical data sheet for Pinnacle (TS) Rubber Wall Base, a resilient flooring product manufactured by Roppe in Fostoria, Ohio. The product is available in eight nominal heights ranging from 2½ inches to 6 inches, with lengths of 48 inches or 120 feet and a thickness of 0.125 inches. It is offered in both traditional cove and no-toe base finishes, with corner options (outside and inside cove corners, and outside no-toe corners) available in select sizes of 2½, 4, and 6 inches. The product meets rigorous performance standards including ASTM F1861 Type TS Group 1 certification, achieves Class I fire rating under ASTM E648, passes smoke density requirements, and carries an ASTM E84 Class B flammability rating. Chemical resistance is excellent per ASTM F925, and the material demonstrates excellent flexibility with no cracking or breaking at 1/4-inch mandrel per ASTM F137.

The product is suitable for indoor use only within a service temperature range of 60–85°F and is compatible with in-floor radiant heating systems. Installation requires Excelsior WB-600 Wall Base Adhesive or Excelsior C-631 Contact Adhesive to obtain the full 5-year limited commercial warranty, which includes bond performance coverage. The material is not lot-controlled and does not require heat welding. The product contributes to LEED v4/4.1 requirements, holds NSF/ANSI 332 Level 1 and FloorScore certifications, meets California Department of Public Health V1.2 requirements, and qualifies for American Made Products Acts. Technical support is available through Roppe at (800) 537–9527 or (844) 393–4044, with additional documentation and installation guidelines available on www.roppe.com.

View the file

Other files

File Type Posted
14. B 24 ELECT DETAILS.docx DOCX document
Micro Air Asbestos Test Report 2009.pdf PDF
10. B24 C WING POWER PLAN 1ST FL.docx DOCX document
9. B24 LIGHTING C WING 2ND FL.docx DOCX document
8. B24 LIGHTING C WING 1ST FL.docx DOCX document
7. PANELBOARD NOR EMERG 3.docx DOCX document
4. PANELS BOARDS EMERG.docx DOCX document
1. PANELBOARDS.docx DOCX document
RFI Questions and Answers_02-09-2026.pdf PDF
36C25726R0043 0003.docx DOCX document
12. B 24 LIGHTING FIXTURES NOTES.docx DOCX document
11. B24 C WING POWER PLAN 2ND FL.docx DOCX document
6. PANELBOARDS NORM EMERG 2.docx DOCX document
5. PANELBAORDS NORM EMERG.docx DOCX document
copy SOW_Rev 2 02_09_2026.pdf PDF
13. B24 DRAWING INDEX V2.docx DOCX document
3. PANELBOARDS NORMAL.docx DOCX document
2. TYPICAL BEDROOM PANELS.docx DOCX document
36C25726R0043 0002.docx DOCX document
12__ Ceramic Tile.pdf PDF
36C25726R0043 0001.docx DOCX document
17__ B24 ACM Report Summary.pdf PDF
16__Water Fountain.pdf PDF
11__Armstrong Flooring-Biome Montaine Uluru 1.pdf PDF
9__B24-B-WING -Build Back Plans 1.pdf PDF
Statement of Work_Rev1_ 01-23-2026.pdf PDF
36C25726R0043_1 Conformed Solicitation.pdf PDF
18__RFI 65 Question_Palladium Doors.pdf PDF
15__Specification Haze Tile-5T037.pdf PDF
Site Visit Sign In Sheet_ Repair Halls and Walls Dm.pdf PDF
13__ Forge Planning Guide.pdf PDF
10__Drawing 24 AF102 Corrected.pdf PDF
1__Consolidated asbuilt 1-8.docx DOCX document
01-23-26 FINAL RFI QAs 36C25726R0043 594A4-22-221 Renovate Halls and Walls DOM.pdf PDF
36C25726R0043_1.docx DOCX document
Price Breakdown Worksheet.pdf PDF
Drawing_ 24-GC100.pdf PDF
Specs_ BONHAM RENOVATE HALLS WALLS FLOORS DOMICILIARY.pdf PDF
Show all 38

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Pinnacle (TS) Rubber Wall Base

TECHNICAL DATA

RHC Technical | 1600 North Union Street - Fostoria, OH 44830 | (844) 393-4044 | 10/17/2024 | Page 1

PRODUCT DESCRIPTION

Finish & Appearance Traditional Cove & No Toe Base Available in all Sizes

Nominal Dimensions 1 2 1/2" (6.4 cm) x 48” (1.22 m) or 120’ (36.58 m) x 0.125” (3.2 mm) 3” (7.6 cm) x 48” (1.22 m) or 120’ (36.58 m) x 0.125” (3.2 mm) 3 1/2” (8.9 cm) x 48” (1.22 m) or 120’ (36.58 m) x 0.125” (3.2 mm) 4” (10.2 cm) x 48” (1.22 m) or 120’ (36.58 m) x 0.125” (3.2 mm) 4 1/2” (11.4 cm) x 48” (1.22 m) or 120’ (36.58 m) x 0.125” (3.2 mm) 5” (12.7 cm) x 48” (1.22 m) or 120’ (36.58 m) x 0.125” (3.2 mm) 5 1/2” (13.9 cm) x 48” (1.22 m) or 120’ (36.58 m) x 0.125” (3.2 mm) 6” (15.2 cm) x 48” (1.22 m) or 120’ (36.58 m) x 0.125” (3.2 mm)

Available Corner Options All available corners have 3" returns Cove Outside Corners are available in 2 1/2", 4”, & 6” sizes Cove Inside Corners are available in 2 1/2", 4”, & 6” sizes No Toe Outside Corners are available in 2 1/2", 4”, & 6” sizes

Non-Available Corner Options No Toe Outside Corners are not available in 3”, 4 1/2", 5”, & 5 1/2" sizes No Toe Inside Corners are not available in any height

PRODUCT PERFORMANCE PROPERTIES

ASTM F1861 – Resilient Wall Base Type TS, Group 1, Styles A & B

ASTM E648 (NFPA 253) – Critical Radiant Flux Class I, ≥ 0.45 W/cm2

ASTM E662 (NFPA 258) – Smoke Density Passes, ≤ 450

ASTM E84 – Flammability Class B

CAN/ULC-S102.2 – Surface Burning 50 Flame Spread Rating 75 Smoke Development Classification

ASTM F925 – Chemical Resistance 2 Excellent, Additional Chemical List available via chart

ASTM F137 – Flexibility Excellent, No Crack or Break 1/4” Mandrel

ASTM F1515 – Light Stability ∆E ≤ 8

PRODUCT INSTALLATION & WARRANTY INFORMATION

Lot Controlled No

Suitable for In Floor Radiant Heat Yes

Heat Weldable / Required No

Indoor / Outdoor Suitability Indoor Use Only

Service & Storage Temperature Range 3 60° - 85° F

Recommended Adhesives 4 Excelsior WB-600 Wall Base Adhesive Excelsior C-631 Contact Adhesive

Product Warranty 5 5 Year Limited Commercial Warranty

VHANTXBehrC Highlight 6” (

VHANTXBehrC Highlight 6” (

VHANTXBehrC Callout

COLOR: CHARCOAL

VHANTXBehrC Architect

Pinnacle (TS) Rubber Wall Base

TECHNICAL DATA

RHC Technical | 1600 North Union Street - Fostoria, OH 44830 | (844) 393-4044 | 10/17/2024 | Page 2

ATTRIBUTES, CERTIFICATIONS, & REGULATORY INFORMATION

• Manufactured in Fostoria, Ohio

• Environmental Product Declaration (EPD) Available

• Contributes to LEED v4/4.1 Requirements

• Achieved NSF/ANSI 332 Level 1 Certification

• Achieved FloorScore Certification

• Meets California Department of Public Health V1.2 (CA Section 01350) requirements

• Meets Collaborative for High Performance Schools (CHPS) requirements

• Qualifies for American Made Products Acts and/or Requirements

SUPPORT & ADDITIONAL DOCUMENTATION

Product Support Phone & Email (800) 537 – 9527 / sales@roppe.com

Technical Support Phone & Email (844) 393 – 4044 / solutions@rhctechnical.com

Product Technical Documentation www.roppe.com

Associated or Related Documentation Excelsior WB-600 Wall Base Adhesive Excelsior C-631 Contact Adhesive Pinnacle Wall Base Installation Wall Base Care & Maintenance Roppe Products Warranty Referenced Standards within Technical Documents Technical Bulletin

1 Nominal Dimensions are the marketed dimensions of the product, tolerances are allowed in the manufacturing process and our tolerance range is what is allowed by the ASTM documentation overseeing the product construction.

2 ASTM F925 testing is utilized to ensure flooring materials will stand up to certain household standard chemistries. Additional chemical resistance testing performed using this test method is for informational and guidance purposes only. Proper maintenance will influence chemical resistance, but the best defense against a negative effect is to clean the drop/spill from the flooring surface immediately.

3 See installation documents for full installation details regarding approved substrates, job site conditions and acclimation procedures.

4 Recommended adhesives listed are recommended to be used to obtain the full listed system warranty that includes a bond performance warranty. Material installed with adhesives other than those listed here or an approved option in writing will only have a product manufacturing and wear warranty, no performance or bond warranty.

5 See product warranty for full details regarding limitations and warranty coverage.

The contents contained within this Technical Data Sheet (TDS) may be utilized or copied into another projected related document, but this original document will remain in effect at the time of product installation, this TDS shall not be supplemented or replaced by the resulting project documentation. Any alterations to the wording or requirements contained in or derived from this document shall void all related warranties.

See installation information and documents for full installation details regarding substrates, job site conditions, & acclimation procedures. The intent of this document is to provide technical and performance properties of the mentioned adhesive as well as define the intended method of installation for the products in which the adhesive is approved for use. Any installation guidelines are to be considered as a starting point at a minimum for a successful installation. We rely on the expertise and professionals that are installing the products to adjust based on site conditions. Anything that appears to be a link, is and leads to additional information if necessary or provides a means of contact in the event there are any additional questions. Prior to acceptance of this document refer to the product website to confirm that you have the most current revision.

These products are intended for installation by professionals, prior to use the user must determine the suitability of our products for the intended use, and the user alone assumes all risks and liability.

mailto:sales@roppe.com mailto:solutions@rhctechnical.com http://www.roppe.com/ https://www.rhctechnical.com/wp-content/uploads/2024/01/Excelsior_600WB_TechnicalData.pdf https://www.rhctechnical.com/wp-content/uploads/2024/01/Excelsior_631C_TechnicalData.pdf https://www.rhctechnical.com/wp-content/uploads/2024/05/Roppe_WallBasePinnacle_Installation.pdf https://www.rhctechnical.com/wp-content/uploads/2024/05/Roppe_WallBasePinnacle_Installation.pdf https://www.rhctechnical.com/wp-content/uploads/2024/03/Roppe_WallBase_CareMaintenance.pdf https://www.rhctechnical.com/wp-content/uploads/2024/01/Roppe_LimitedWarranty.pdf https://www.rhctechnical.com/wp-content/uploads/2024/05/TechnicalBulletin013_ReferencedStandardsWithinTechnicalDocuments.pdf