Final Drawings Part-2.pdf

PDF 8 MB Posted

Attached to
Z2DA--589A4-25-102, Install Dedicated Pharmacy Air Handler Federal contract opportunity
Solicitation number
36C25526R0159
Issued by
Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 15

About this file

This file is a set of final construction drawings (Part 2) for a federal healthcare facility renovation project. The project involves installing a dedicated pharmacy air handler at Harry S. Truman Veterans Affairs Medical Center (VAMC) in Columbia, Missouri. The 100% bid-level drawings dated June 11, 2026, are organized across 73 sheets and address roofing, architectural, mechanical, electrical, fire protection, and structural components.

The scope of work includes roof repair and patching with new TPO membrane roofing system (R-30 with 6" rigid insulation), new roof walkway pads, and mechanical penetration flashing. Architectural work encompasses ceiling demolition and reinstallation, interior partitions, door frames, finishes (carpet tile, luxury vinyl tile), and flooring transitions. Fire protection systems include fire alarm (Siemens-based), smoke detection relocation due to ceiling work, and wet pipe sprinkler system protection during construction. The project must comply with NFPA standards (13, 70, 72, 90A, 96, 101), International Building Code 2024, and VA Fire Protection Design Manual Ninth Edition 2023. Work is limited to basement and levels 1-3 of the facility, with specific demolition areas identified for existing ceiling-mounted equipment requiring protection and reinstallation. All contractors must be approved by existing roof manufacturers to maintain warranty compliance, coordinate with mechanical and electrical trades, and deliver systems in like-new condition upon completion. The facility is fully sprinklered, and all roofing work, support systems, and new installations must maintain existing and new equipment warranties.

View the file

Other files for this federal contract opportunity

Other files attached to Z2DA--589A4-25-102, Install Dedicated Pharmacy Air Handler, newest first.
File Type Posted
07 81 00 Applied Fireproofing.pdf PDF
36C25526R0159 0004.pdf PDF
PRE-BID SIGN IN ROSTER.pdf PDF
Final Drawings Part-3.pdf PDF
Final Drawings Part-1.pdf PDF
36C25526R0159 0003.docx DOCX document
07_8100-001_Fireproofing_Mfr_Literature.pdf PDF
589a4-25-102_Addendum 02_260828.pdf PDF
01 00 00 General Requirements RX.pdf PDF
36C25526R0159 0002.docx DOCX document
finish schedule from specs.pdf PDF
01 00 10 - MEDICAL CENTER REQUIREMENTS RX.pdf PDF
Finish schedule from drawings.pdf PDF
01 33 23- Shop Drawings Product DAta and Samples.pdf PDF
Phasing info.pdf PDF
01 32 16-15 Project Schedules RX.pdf PDF
01 91 00 General Commissioning Requirements RX.pdf PDF
36C25526R0159 0001.docx DOCX document
S02-Final Specifications 1068 pages.pdf PDF
36C25526R0159.docx DOCX document
P09-Final Drawings Part-2 Pages 37.pdf PDF
P09-Final Drawings Part-1 Pages 37.pdf PDF
Show all 22

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

ROOF WALKWAY PAD

X:XX ROOF PITCH

VENT PIPE

EXHAUST FAN;

REF. MECHANICAL

VP

EF

ROOF PLAN PLAN LEGEND

NOTE: ALL SYMBOLS MAY NOT BE USED.

AREA NOT IN CONTRACT

1. ALL ROOFING WORK SHALL BE PERFORMED BY CONTRACTOR APPROVED BY EXISTING ROOF

MANUFACTURER TO PATCH AND REPAIR EXISTING ROOFING SYSTEM. CONTRACTOR SHALL BE

RESPONSIBLE FOR CHECKING EXISTING ROOFING SYSTEM WARRANTY STATUS AND

FURNISHING A COMPLETE ROOF REWORK, REPAIR AND PATCHING SYSTEM THAT WILL BE IN

COMPLIANCE WITH ANY EXISTING REMAINING ROOF WARRANTIES. NEW WORK SHALL PROVIDE

FULL NEW SYSTEM WARRANTIES.

2. PROVIDE PIPE BOOTS FLASHED INTO EXISTING ROOF AT ALL SANITARY VENT LINES,

ELECTRICAL SERVICE STANCHIONS AND WEATHERHEADS, CHILLED WATER LINES, AND OTHER

MISCELLANEOUS PENETRATIONS NOT ILLUSTRATED ON ARCHITECTURAL ROOF PLAN. SEE

MECHANICAL.

3. SUPPORTS ALLOWED TO SIT DIRECTLY ON ROOF SYSTEM FOR PIPING AND SIMILAR SHALL BE

PURPOSE MADE BY MANUFACTURER FOR APPLICATION AND SUPPORT ROOF SYSTEM EXISTING

AND NEW WARRANTIES. SEE MECHANICAL.

4. PROVIDE ROOF WALKWAY FROM NEW ACCESS POINT TO NEW ROOFTOP MECHANICAL

EQUIPMENT WHERE INDICATED.

5. REFER TO ELECTRICAL DRAWINGS FOR LIGHTNING PROTECTION SYSTEMS.

6. REFER TO STRUCTURAL DRAWINGS FOR ADDITIONAL DEMOLITION INFORMATION.

7. CONTRACTOR TO LOCATE AND IDENTIFY EXISTING STRUCTURAL MEMBERS AND ROOF

CONDITIONS, AND REPORT ANY DISCREPANCIES TO THE VA BEFORE COMENCING

CONSTRUCTION.

GENERAL ROOF PLAN NOTES

F

E

D

10 11

C

E.1

D.7

B

11.5 1312

EX. EF

EX. EF

22.01

AE201

S L O

P E

S L O

P E

SLOPE

AE201

8.48

AE104

AE104

7.232

'-0

/2

AE201

23.19

KEY PLAN

N

SCOPE

AREA

ROOF DECK

EL. VARIES

2'- 0" MIN.

ROOF DRAIN

2'- 0" MIN.

7.131

7.219

7.218

22.01

7.221

7.222

7.223

7.224

7.225

7.131

7.216

7.211

7.33

7.217

/2

2 1/2"

ROOF DECK

EL. VARIES

PER MANUFACTURER

2.105

7.131

7.228

7.227

7.226

7.2167.2317.229 7.2307.216

EXISTING ROOF

2.105 7.08 th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t

A

B

C

D

E

F

Veterans Health

Administration

VA FORM 08-6231

DRAWING TITLE PROJECT TITLE

LOCATION

DATE CHECKED DRAWN

PROJECT NUMBERCONSULTANTS:

DRAWING #

VA HEALTH CARE SYSTEM APPROVAL:

ARCHITECT:

SPUR DESIGN, LLC

312 SW 25TH STREET

Oklahoma City, OK 73109

(405) 842-6100

ARCH REG. NO. A-2012034754 EXP. 12/31/2026

ENGR REG. NO. E-2014031351 EXP. 12/31/2026

FULLY SPRINKLERED

1 2 3 4 5 6 7 8 9

1 2 3 4 5 6 7 8 9

A

B

C

D

E

F

STAMP:

DRAWING NUMBER

BUILDING NUMBER

CIVIL/STRUCTURAL

H2B ENGINEERING

1225 NORTH LOOP WEST, SUITE 800

HOUSTON, TX 77008

(713) 864-2900

PHYSICAL SECURITY

FORCE PROTECT

4015 VITRUVIAN WAY, UNIT 1212

ADDISON, TX 75001

PHONE NUMBER

MECH/ELEC/PLUMB/TECH ENGINEER

SPUR DESIGN

312 SW 25TH STREET

OKLAHOMA CITY, OK 73109

(405) 842-6100

FIRE PROTECTION ENGINEER

RATED ENGINEERING

609 S. KELLY AVE., SUITE H2

EDMOND, OK 73003

(405) 210-5814

/8

/2

:4

:3

P

M

PENTHOUSE ROOF PLAN AND DETAILS

JDM 22 OF 74BKM

100% BID DOCUMENTS

INSTALL DEDICATED

PHARMACY AIR HANDLER

06/11/2026

589A4-25-102

HARRY S. TRUMAN VAMC

800 HOSPITAL DRIVE

COLUMBIA, MO 65201

AE104

SPUR #: 2517

KEYNOTE LEGEND

2.105 EXISTING ROOF TO REMAIN

7.08 NEW ROOFING SYSTEM TO TIE INTO AND ALIGN WITH EXISTING ROOF; REF. 4/AE104

7.33 COUNTERFLASHING SYSTEM

7.131 R-30 ROOF WITH 6" RIGID INSULATION

7.211 CONTINUOUS WOOD NAILER

7.216 TPO ROOF MEMBRANE

7.217 SHEET METAL COVER

7.218 DECK CLAMP

7.219 PROTECTION BOARD AND METAL DECKING. PROVIDE TREATED WOOD BLOCKING AS

REQUIRED

7.221 THERMOPLASTIC MEMBRANE ROOFING SYSTEM

7.222 MINIMUM 1 1/2" HOT AIR WELD

7.223 TOP LAP SEALANT

7.224 CLAMPING RING

7.225 WATER CUT-OFF MASTIC

7.226 CONTINOUS WEATHER BARRIER UNDERLAYMENT

7.227 COVER BOARD

7.228 APPLY MASTIC OVER INSULATION FASTENERS

7.229 PROVIDE 6" OF OVERLAPPING MEMBRANE OVER FLASHING

7.230 CUT EXISTING ROOFING WHERE NECESSARY FOR INSTALLATION OF NEW ROOFING SYSTEM

7.231 SINGLE PLY FLASHING MEMBRANE FASTENED OR ADHERED PER MANUFACTURER

7.232 ROOF CRICKET

8.48 6'-0" X 6'-0" ROOF HATCH AND CURB

22.01 ROOF DRAIN; REF. PLUMBING DRAWINGS

23.19 EXHAUST FAN; REF. MECHANICAL DRAWINGS

N

1/8" = 1'-0"

ROOF PLAN1

1 1/2" = 1'-0"

OVERFLOW DRAIN DETAIL3

6" = 1'-0"

CURB DETAIL2

6" = 1'-0"

NEW ROOF SYSTEM TO EXISTING ROOF DETAIL4

No. REVISION DESCRIPTION DATE

GENERAL REFLECTED CEILING PLAN NOTES

1. ALL CEILINGS 9'-0" AFF UNO.

2. ALL SURFACES OF SOFFITS TO BE PAINTED XX UNO.

3. WHERE EXISTING CEILINGS ARE TO BE REMOVED AND REPLACED WITH NEW, THE GENERAL

CONTRACTOR SHALL COORDINATE THE REMOVAL AND REINSTALLATION OF ALL CEILING

MOUNTED DEVICES (CUBICLE CURTAIN TRACKS, IV-TRACKS, DETECTORS, SPEAKER, ETC.)

SEE MECHANICAL AND ELECTRICAL DRAWINGS FOR ADDITIONAL INFORMATION ON THE

ROUTING OF THE NEW SERVICES ABOVE THE CEILING.

EXIT LIGHT OR SIGN

REF: LIFE SAFETY

2' x 2' ACOUSTICAL CEILING

GYPSUM BOARD CEILING OR

SOFFIT

2 x 2 LIGHT FIXTURE

REF: ELECTRICAL

CEILING HEIGHT, ABOVE

FINISH FLOOR

RECESSED CAN LIGHT

(CENTER IN TILE U.N.O.)

REF: ELECTRICAL

2 x 4 LIGHT FIXTURE

REF: ELECTRICAL

00'-00"

REFLECTED CEILING PLAN LEGEND

2' x 4' ACOUSTICAL CEILING

RETURN AIR GRILLE

REF: MECHANICAL

SUPPLY AIR DIFFUSER

REF: MECHANICAL

EXHAUST AIR GRILLE

REF: MECHANICAL

SUSPENDED LIGHT FIXTURE

REF: ELECTRICAL

NOTE: ALL SYMBOLS MAY NOT BE USED.

OCCUPANCY SENSOR

REF: ELECTRICAL

AREA NOT IN SCOPE

PARTITION LEGEND

NOTE: NOT ALL WALL TYPES MAY BE USED

EXISTING WALL TO REMAIN

EXISTING HORIZONTAL EXIT

(& REFUSE AREA)

FIRE BARRIER

EXISTING BUILDING

SEPARATION: FIRE BARRIER

(FIRE WALL IN IBC)

EXISTING SUBDIVIDED SPACE

SMOKE BARRIER

EXISTING HAZ./INCIDENTAL

USE SMOKE BARRIER

(SPRINKLERED)

NEW PARTITION WALL;

REF. AE001

3 4 5 6 7 8 9

F

E

D

10 112

C

E.1

D.7

B

6.3 11.5

E002F

CONFERENCE

ROOM

E002E

PROGRAM

SUPPRT R&D

E002C

A.O. RAD

E002D

CORRIDOR

CBE3

MECHANICAL

ROOM

E003

MECHANICAL

ROOM

E003

FREEZER

F030A

REFRIGERATOR

F030

CAMERA DARK

ROOM

F031

MICRO DARK

ROOM

F032

ELEC

CLOSET

F035

WORK ROOM

F002

OFFICE

F003

WORK ROOM

F006

OFFICE

F007

OFFICE

F008

OFFICE

F009

VESTIBULE

F009A

SHARED OFFICE

F011

JANITOR

F036

STAIR

#11

JANITOR

E013

STORAGE

E001G

PHARMACY

E001

TELE / DATA

E006

ELEV MACHINE

ROOM

E007

WOMAN TOILET

E010

MEN TOILET

E008

ELEC ROOM

E009

CORRIDOR

CBE2

CORRIDOR

CBE2

OFFICE

E002A

RESEARCH

SERVICE

CORRIDOR

E002

CORRIDOR

CBF1

CORRIDOR

CBE5

E005

ELEV

#10

ELEV

#9

ELEV

#11

E004CORRIDOR

CBE4

MECHANICAL

ROOM

E003A

9'-0"

9'-0"

9'-0" 9'-0"9'-0"9'-0"

9.170

9.1709.1709.1709.170

9.170

9.170

2.96

OFFICE

E002H

R.C.O. R&D

E002I

CLINICAL

RESEARCH

E002J

MFMR EXEC

OFFIC

E002K

WORK ROOM

E002B

9.170

9'-0"

10'-0"

F033

9'-0"

9.170

STORAGE

E002E

NON-HAZARD IV

PREP

E001H

STERILE

PROCESSING

AREA

E001L

IV ROOM

STORAGE

E001F

HAZARDOUS

IV PREP

E001J

HAZARDOUS

DRUG

STORAGE

E001K

TEAM ROOM

E001D

OFFICE

E001B

NARCOTIC

VAULT

E001A

OFFICE

E001C

CHASE

9.170

9.170

9.170

9.170

9.170

9.170

9.170

9.170

9'-0"

KEY PLAN

N

SCOPE AREA

th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t

A

B

C

D

E

F

Veterans Health

Administration

VA FORM 08-6231

DRAWING TITLE PROJECT TITLE

LOCATION

DATE CHECKED DRAWN

PROJECT NUMBERCONSULTANTS:

DRAWING #

VA HEALTH CARE SYSTEM APPROVAL:

ARCHITECT:

SPUR DESIGN, LLC

312 SW 25TH STREET

Oklahoma City, OK 73109

(405) 842-6100

ARCH REG. NO. A-2012034754 EXP. 12/31/2026

ENGR REG. NO. E-2014031351 EXP. 12/31/2026

FULLY SPRINKLERED

1 2 3 4 5 6 7 8 9

1 2 3 4 5 6 7 8 9

A

B

C

D

E

F

STAMP:

DRAWING NUMBER

BUILDING NUMBER

CIVIL/STRUCTURAL

H2B ENGINEERING

1225 NORTH LOOP WEST, SUITE 800

HOUSTON, TX 77008

(713) 864-2900

PHYSICAL SECURITY

FORCE PROTECT

4015 VITRUVIAN WAY, UNIT 1212

ADDISON, TX 75001

PHONE NUMBER

MECH/ELEC/PLUMB/TECH ENGINEER

SPUR DESIGN

312 SW 25TH STREET

OKLAHOMA CITY, OK 73109

(405) 842-6100

FIRE PROTECTION ENGINEER

RATED ENGINEERING

609 S. KELLY AVE., SUITE H2

EDMOND, OK 73003

(405) 210-5814

/8

/2

:3

:5

P

M

REFLECTED CEILING PLAN - BASEMENT

LEVEL

JDM 23 OF 74JP

100% BID DOCUMENTS

INSTALL DEDICATED

PHARMACY AIR HANDLER

06/11/2026

589A4-25-102

HARRY S. TRUMAN VAMC

800 HOSPITAL DRIVE

COLUMBIA, MO 65201

AC131

SPUR #: 2517

KEYNOTE LEGEND

2.96 EXISTING CEILING OPEN TO STRUCTURE ABOVE

9.170 REINSTALLED CEILING AS SCHEDULED

N

1/8" = 1'-0"

BASEMENT - REFLECTED CEILING PLAN1

LEVEL 3

33'-0"

EX. ROOF

49'-0"

9 10 11 11.5 1312

INTERSTITIAL LEVEL

26'-4 3/4"

EX. ROOF

4.03

7.06

2.100 2.76

AE201

AE201

2.103

2.99

2.104 1.31

2.104

26'-6 1/2"EXISTING BUILDING

3' -2

8"

F

9A

7.10

7.234

LEVEL 3

33'-0"

EX. ROOF

49'-0"

EDC E.1D.7

INTERSTITIAL LEVEL

26'-4 3/4"

23.17 23.17

'-7

/4

7.06

4.03

2.99

2.1041.31

7.10

2.104

2.103

28'-6 1/2" EXISTING BUILDING

7.234

1. REFER TO PLANS FOR ELEVATION LOCATIONS.

GENERAL BUILDING ELEVATION NOTES

1. REFER TO PLANS FOR SECTION LOCATIONS.

2. THE CONTRACTOR SHALL VERIFY DIMENSIONS, AND NOTIFY THE ARCHITECT IN WRITING OF ANY

DISCREPANCIES. ALL INFORMATION SHOWN ON THE CONSTRUCTION DOCUMENTS IS BASED ON

FIELD OBSERVATIONS AND/OR THE ORIGINAL CONSTRUCTION DOCUMENTS OF THE FACILITY.

3. THE CONTRACTOR SHALL PROVIDE PROTECTIVE COVERING IN AREAS NOT DESIGNATED FOR NEW

CONSTRUCTION. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE REPAIR OF ANY DAMAGE

CAUSED BY THEIR WORK OR ANY SUBCONTRACTOR.

GENERAL WALL SECTION NOTES

LEVEL 3

33'-0"

EX. ROOF

49'-0"

DC

INTERSTITIAL LEVEL

26'-4 3/4"

MECHANICAL

PENTHOUSE

F399

ACA-AHU-12

ACA-AHU-11

ELEC

F396

22.01

AE201

8.48

INTERSTITIAL

SPACE

F399A

'-0

23.19

23.20

TYP.

EXISTING

INTERSTITIAL

SPACE

F

1/4" / 1'-0" 1/4" / 1'-0"

23.11

23.11

23.19

AE201

LEVEL 3

33'-0"

EX. ROOF

49'-0"

C

INTERSTITIAL LEVEL

26'-4 3/4"

7.122

7.130

7.97

6.09

MECHANICAL

PENTHOUSE

F399

9.06

9.120

INTERSTITIAL

SPACE

AE201

ACA-AHU-11

23.11

3.07

23.20

7.70

9.17

5.01

5.01

5.01

AE201

2.51

7.210

5.01

7.102

7.101

7.33

7.130

7.09

9.17

7.216

7.122 7.131

6.03

8" M

IN

2.105

7.08 7.96

7.103

6.09

7.34

7.35

9.06

7.80

7.1357.233

1/4" / 1'-0"6.90

7.215

ROOF DECK

EL. VARIES

7.09

6.03

7.214

7.130

5.01

7.131

7.216

7.96

7.122 5.23

7.213

7.215

1' -0

6"

C

6.09

5.01

2.992.76

9.17

7.97

6.09 7.130 2.103

1.31

1.31

1' -1

/2

7.10

1' -0

7.11

ROOF DECK

EL. VARIES

5.01

7.213

7.131

7.12

7.122

7.96th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t

A

B

C

D

E

F

Veterans Health

Administration

VA FORM 08-6231

DRAWING TITLE PROJECT TITLE

LOCATION

DATE CHECKED DRAWN

PROJECT NUMBERCONSULTANTS:

DRAWING #

VA HEALTH CARE SYSTEM APPROVAL:

ARCHITECT:

SPUR DESIGN, LLC

312 SW 25TH STREET

Oklahoma City, OK 73109

(405) 842-6100

ARCH REG. NO. A-2012034754 EXP. 12/31/2026

ENGR REG. NO. E-2014031351 EXP. 12/31/2026

FULLY SPRINKLERED

1 2 3 4 5 6 7 8 9

1 2 3 4 5 6 7 8 9

A

B

C

D

E

F

STAMP:

DRAWING NUMBER

BUILDING NUMBER

CIVIL/STRUCTURAL

H2B ENGINEERING

1225 NORTH LOOP WEST, SUITE 800

HOUSTON, TX 77008

(713) 864-2900

PHYSICAL SECURITY

FORCE PROTECT

4015 VITRUVIAN WAY, UNIT 1212

ADDISON, TX 75001

PHONE NUMBER

MECH/ELEC/PLUMB/TECH ENGINEER

SPUR DESIGN

312 SW 25TH STREET

OKLAHOMA CITY, OK 73109

(405) 842-6100

FIRE PROTECTION ENGINEER

RATED ENGINEERING

609 S. KELLY AVE., SUITE H2

EDMOND, OK 73003

(405) 210-5814

/8

/2

:3

:2

P

M

BUILDING ELEVATIONS AND SECTIONS

JDM 24 OF 74BKM

100% BID DOCUMENTS

INSTALL DEDICATED

PHARMACY AIR HANDLER

06/11/2026

589A4-25-102

HARRY S. TRUMAN VAMC

800 HOSPITAL DRIVE

COLUMBIA, MO 65201

AE201

SPUR #: 2517

1/8" = 1'-0"

BUILDING ELEVATION - SOUTH1

1/8" = 1'-0"

BUILDING ELEVATION - EAST4

KEYNOTE LEGEND

1.31 ALIGN

2.51 EXISTING CONCRETE BEAM TO REMAIN

2.76 EXISTING WINDOW SYSTEM SHALL REMAIN

2.99 EXISTING EIFS WALL ON ROOF TO REMAIN

2.100 EXISTING WALL FEATURE TO REMAIN

2.103 EXISTING CONCRETE PANEL EXTERIOR TO REMAIN

2.104 EXISTING ROOF PARAPET TO REMAIN

2.105 EXISTING ROOF TO REMAIN

3.07 CONCRETE HOUSEKEEPING PAD; REF. STRUCTURAL DRAWINGS

4.03 CONCRETE PANEL WALL TO MATCH EXISTING

5.01 STRUCTURAL STEEL; REF. STRUCT. DRAWINGS

5.23 6" METAL STUD TRACK

6.03 5/8" PLYWOOD SHEATHING (NAILABLE)

6.09 5/8" EXTERIOR GYPSUM SHEATHING

6.90 WOOD BLOCKING

7.06 ACRYLIC-BASED EIFS OVER 2" EPS INSULATION TO MATCH EXISTING: R-3.85 PER INCH = R7.7

7.08 NEW ROOFING SYSTEM TO TIE INTO AND ALIGN WITH EXISTING ROOF; REF. 4/AE104

7.09 6" BATT INSULATION, R-13 MINIMUM

7.10 COMPRESSIBLE FOAM EXPANSION JOINT

7.11 1/4" SEALANT, EACH SIDE

7.12 FLEXIBLE WALL BELLOWS EXPANSION JOINT SYSTEM

7.33 COUNTERFLASHING SYSTEM

7.34 THRU-WALL FLASHING

7.35 TRANSITION MEMBRANE

7.70 FLUID-APPLIED AIR BARRIER

7.80 AIR VAPOR BARRIER

7.96 CANT STRIP

7.97 BATT INSULATION, R-13 MIN.

7.101 WEEP SCREED. MAINTAIN PATH ABOVE THRU-WALL FLASHING FOR WATER MIGRATION.

7.102 PAN FLASHING PER ROOF MANUFACTURER'S REQUIREMENTS

7.103 TERMINATION BAR

7.122 ROOF AND DECK INSULATION

7.130 DRAINABLE EXTERIOR INSULATION AND FINISH SYSTEM (EIFS)

7.131 R-30 ROOF WITH 6" RIGID INSULATION

7.135 FIRE RESISTENT JOINT SEALANT

7.210 PARAPET

7.213 TPO MEMBRANE BONDING ADHESIVE

7.214 TPO MEMBRANE LAPPED UP AND OVER PARAPET

7.215 PREFINISHED METAL COPING

7.216 TPO ROOF MEMBRANE

7.233 ROOF AIR BARRIER

7.234 CAP FLASHING COVER AT BUILDING JOINT

8.48 6'-0" X 6'-0" ROOF HATCH AND CURB

9.06 6" C STUD

9.17 5/8" GYPSUM WALL BOARD

9.120 FLOORING AS SCHEDULED

22.01 ROOF DRAIN; REF. PLUMBING DRAWINGS

23.11 AIR HANDLING UNIT (AHU); REF. MECHANICAL DRAWINGS

23.17 LOUVER; REF. MECHANICAL DRAWINGS

23.19 EXHAUST FAN; REF. MECHANICAL DRAWINGS

23.20 EQUIPMENT CURB; REF. MECHANICAL DRAWINGS

1/4" = 1'-0"

BUILDING SECTION - EAST6

1/2" = 1'-0"

WALL SECTION2

1 1/2" = 1'-0"

TYP. PARAPET DETAIL AT EIFS5

1 1/2" = 1'-0"

HORIZONTAL ROOF AT WALL DETAIL3

1 1/2" = 1'-0"

LEVEL 3 - PLAN DETAIL - EXISTING TO NEW WALL8

No. REVISION DESCRIPTION DATE

1 1/2" = 1'-0"

TYP. DETAIL AT EXISTING ROOF7

A B C F G

D E

2" 5/

8"

1 15/16" VARIES 1 9/16"

1/2"

INT. STUD WALLS

WALL THICKNESS AT 1/2"

RE: DOOR SCHEDULE

FRAME DEPTH

1 15/16" VARIES 1 9/16"

1/2"

INT. STUD WALLS

WALL THICKNESS AT 1/2"

RE: DOOR SCHEDULE

FRAME DEPTH

1/2"

INT. STUD WALLS

WALL THICKNESS AT 1/2"

RE: DOOR SCHEDULE

FRAME DEPTH

1/2"

INT. STUD WALLS

WALL THICKNESS AT 1/2"

RE: DOOR SCHEDULE

FRAME DEPTH

RE: DOOR SCHEDULE

FRAME DEPTH

1/2"

INT. STUD WALLS

WALL THICKNESS AT 1/2"

RE: DOOR SCHEDULE

FRAME DEPTH

1 15/16" VARIES 1 9/16"

VARIES 1 15/16" VARIES 1 15/16" VARIES 1 9/16" 1 15/16" VARIES 1 9/16" 2 37/256"

65/128"

113/256"

65/128"

VARIES

RE: DOOR SCHEDULE

FRAME DEPTH

1 15/16" VARIES 1 9/16"

APPLIED

STOPS

APPLIED

STOP APPLIED

STOP

APPLIED

STOP

2 3/16"

65/128"

51/128"

65/128"

VARIES

5/ 8"

2" 5/

8"

2" 5/

8"

5/ 8"

2" 5/

8"

2" 5/

8"

2" 5/

8"

5/ 8"

4" 5/

8"

NOTE: NOT ALL FRAME TYPES MAY BE USED

3" V

A R

IE

S

6"

2" 2'-9" 2" 2'-9" 2"

F

SCHED. DIM.

S C

H E

D . D

IM

SCHED. DIM.

S C

H E

D . D

IM

SCHED. DIM.SCHED. DIM.

S C

H E

D . D

IM

S C

H E

D . D

IM

.2' -0

4'

-0

2' -0

6"

V A

R

IE

S 6"

6" 4"

4' -0

2'

-6

6" VARIES 6" 6" VARIES 6"

FFE

SCHED. DIM.

S C

H E

D . D

IM

V A

R

IE

S 6"

6" 2'-6"

NL HL DL FL

FULL LITEDOUBLE LITEHALF LITENARROW LITEFLUSH

SCHED. DIM.

S C

H E

D . D

IM

5' -0

EQ 10" EQ

VL

VISION LITE SLIDING GLASS

SG

S C

H E

D . D

IM

NOTES

1. NOT ALL FRAME ELEVATIONS

MAY BE USED

2. 1/4" FIRE GLASS AT RATED

DOORS*

- TEMPERED GLAZING

AP

ACCESS PANEL

3' -0

S

C H

E D

. D

IM

SCHED. DIM.

HM-1

NOTE: NOT ALL FRAME

ELEVATIONS MAY BE USED

2"

DIM.

SCHED. 2"

2"

2" S

C H

E D

. D

IM

2"

DIM.

SCHED. 2"

2" S

C H

E D

. D

IM

2" S

C H

E D

. D

IM

2"

DIM.

SCHED. 2"

G2

FFE

STANDARD FRAME

INTERIOR DETAILS:

HEAD: 4/AE601

JAMB: 5/AE601

HM-2

4" S

C H

E D

. D

IM

2"

DIM.

SCHED. 2"

STANDARD FRAME (MASONRY)

INTERIOR DETAILS:

HEAD: 4/AE601

JAMB: 5/AE601

HM-3

DOUBLE EGRESS FRAME

INTERIOR DETAILS:

HEAD: 4/AE601

JAMB: 5/AE601

HM-4

INTERIOR DETAILS:

HEAD: 4/AE601

JAMB: 5/AE601

SIDELITE FRAME

HM-0

2" S

C H

E D

. D

IM

2"

DIM.

SCHED. 2"

FRAMED OPENING

INTERIOR DETAILS:

HEAD: 4/AE601

JAMB: 5/AE601

ACCESS PANEL FRAME

HM-AP

INTERIOR DETAILS:

HEAD: 4/AE601

JAMB: 5/AE601

1 1/2"

DIM.

SCHED. 1 1/2"

3' -0

1/

2"

S C

H E

D . D

IM

1/

2"

9.20

9.05

7.135

8.01

8.01

7.135

9.05

9.20

U.N.O.

4" TYP.

FLOOR SLAB

NEW

EX. FLOOR SLAB

8"

1/ 4"

1/ 4"

SLOPE MAX.

8.12

8.95

8.96

CARPET TILE

RUBBER REDUCER

STRIP, FINISH: TR3

SEALED CONCRETE

LUXURY VINYL

TILE

RUBBER REDUCER

STRIP, FINISH: TR3

SEALED CONCRETE

th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t

A

B

C

D

E

F

Veterans Health

Administration

VA FORM 08-6231

DRAWING TITLE PROJECT TITLE

LOCATION

DATE CHECKED DRAWN

PROJECT NUMBERCONSULTANTS:

DRAWING #

VA HEALTH CARE SYSTEM APPROVAL:

ARCHITECT:

SPUR DESIGN, LLC

312 SW 25TH STREET

Oklahoma City, OK 73109

(405) 842-6100

ARCH REG. NO. A-2012034754 EXP. 12/31/2026

ENGR REG. NO. E-2014031351 EXP. 12/31/2026

FULLY SPRINKLERED

1 2 3 4 5 6 7 8 9

1 2 3 4 5 6 7 8 9

A

B

C

D

E

F

STAMP:

DRAWING NUMBER

BUILDING NUMBER

CIVIL/STRUCTURAL

H2B ENGINEERING

1225 NORTH LOOP WEST, SUITE 800

HOUSTON, TX 77008

(713) 864-2900

PHYSICAL SECURITY

FORCE PROTECT

4015 VITRUVIAN WAY, UNIT 1212

ADDISON, TX 75001

PHONE NUMBER

MECH/ELEC/PLUMB/TECH ENGINEER

SPUR DESIGN

312 SW 25TH STREET

OKLAHOMA CITY, OK 73109

(405) 842-6100

FIRE PROTECTION ENGINEER

RATED ENGINEERING

609 S. KELLY AVE., SUITE H2

EDMOND, OK 73003

(405) 210-5814

/8

/2

:4

:0

P

M

DOOR SCHEDULE & DETAILS

JDM 25 OF 74BKM

100% BID DOCUMENTS

INSTALL DEDICATED

PHARMACY AIR HANDLER

06/11/2026

589A4-25-102

HARRY S. TRUMAN VAMC

800 HOSPITAL DRIVE

COLUMBIA, MO 65201

AE601

SPUR #: 2517

3" = 1'-0"

DOOR FRAME TYPES3

1/4" = 1'-0"

DOOR TYPES11/4" = 1'-0"

HOLLOW METAL FRAME ELEVATIONS2

KEYNOTE LEGEND

7.135 FIRE RESISTENT JOINT SEALANT

8.01 METAL DOOR & FRAME

8.12 SLIDING WOOD DOOR

8.95 LAMINATED GLASS

8.96 FIRE-RATED GLASS

9.05 3 5/8" C STUD

9.20 5/8" TYPE X GYPUSM WALLBOARD

3" = 1'-0"

TYP. HM HEAD DETAIL - INTERIOR43" = 1'-0"

TYP. HM JAMB DETAIL - INTERIOR53" = 1'-0"

ACCESSIBLE DOOR THRESHOLD6

DOOR SCHEDULE

MARK ROOM NAME

DOOR PANEL FRAME FIRE RATING

HARDWARE

SET

T E

LE

C

O M

COMMENTS

TYPE MATERIAL WIDTH HEIGHT TYPE

IN

C1F22 CORRIDOR AP MTL 2'-6" 3'-0" HM-AP ● 090 RATED ACCESS PANEL; REF. 1/AE601 AND 2/AE601

E210 REFRAC. AP MTL 2'-6" 3'-0" HM-AP ● 090 RATED ACCESS PANEL; REF. 1/AE601 AND 2/AE601

F300 WAITING AP MTL 2'-6" 3'-0" HM-AP ● 090 RATED ACCESS PANEL; REF. 1/AE601 AND 2/AE601

F399 PAIR-F MTL 8'-0" 7'-0" HM-1 090

F399A INTERSTITAL SPACE AP MTL 3'-0" 3'-0" HM-AP ● 090 RATED ACCESS PANEL; REF. 1/AE601 AND 2/AE601

12" = 1'-0"

TRANSITION DETAIL - CPT TO SEALED CONCRETE17

12" = 1'-0"

TRANSITION DETAIL - LVT TO SEALED CONCRETE8

No. REVISION DESCRIPTION DATE

ROOM FINISH SCHEDULE

ROOM # ROOM NAME

FLOOR FINISHES WALL FINISHES

CEILING

COMMENTSMATERIAL BASE PLAN NORTH PLAN EAST PLAN SOUTH PLAN WEST

C1F22 CORRIDOR ETR ETR ETR ETR ETR ETR ACT1 REF. PLAN AE101, 1/AE101, 2/AE101, 3/AE101, 4/AE101

E210 REFRAC. ETR ETR ETR P1 ETR ETR ACT1 REF. PLAN AE101, 5/AE101, 6/AE101, 7/AE101, 8/AE101

F300 WAITING ETR ETR ETR P1 ETR ETR ACT1 REF. PLAN AE103, 3/AE103, 4/AE103, 5/AE103, 6/AE103

F399 MECHANICAL PENTHOUSE EPY1 RB1 P1 P1 P1 P1 OTS REF. PLAN AE103, 1/AE103, 2/AE103

F399A INTERSTITAL SPACE EPY1 RB1 P1 P1 P1 P1 OTS REF. PLAN AE102, 2/AE102

C B

E

E001

E009

E002B

E002H E002I E002J E002K

E003

C O

R R

E001E

DN

UP

UPDN

F001B

F003*

JAN.

VEST.

CORR.

STAIR

#11

HATCH TO

TUNNEL BELOW

ELEV

#11

ELEV

#10

ELEV

#9

F023A

CBF3

F024

F001A

F004

F021

F018

F020 F019

F017 F016

F015A

F015

F014

C B

F

F005 F010

F012

F013

F011 F036 F009A

F003 F006 F007 F008 F009

CBF5

F001

F002A

F002

CBF1

E010

E008

E007

E006

CBE2

CBE5

CBE2

E004

E005

F037

E001K

E001H

E001L

E002F

E002E

E002D E002C

E002A

E002

A001

CORR-1

F029 F028

F027A

F028A F025

F025A

F027 F026

F034

F034A

F035A

F035

F030 F031 F032 F033

F030A

F023 F022

CBE4

C B

F

F029A

E001F

E001J

CORR.

CORR.

CORR.

C O

R R

C O

R R

E001BE001D

E001A

OFFICETEAM ROOM

NARCOTIC

VAULT

E001C

OFFICE

STERILE PROCESSING AREA

NON-HAZARD IV PREP

IV STORAGE ROOM

STORAGE

CORRIDOR

HAZARDOUS

DRUG STORAGE

HAZARDOUS

IV PREP

OFFICE

F

F

F175

F174C

F174B

F174A

F181

F176

F174

E-1100

E139

E144

E140

F169

E146

E148

E147

C1E8 E145

E143

F179B

F177

F160

F177A F178

F161

F164

F166

F167

F165

F162

F170

E100A

E138

TLT.

CORR

F.M.S. ENG.

F.M.S. ENG.

ENTR.

VEST.

LOBBY

STAIR

#11DN

UP

C1F22

CORR.

F F

UP

FE

FE

FE

FE

FE

FE

UP UP

FE

C1E33

C1E31

E125F E109 E110

C1E24

E125EE125A E125B E125C E125D

E124

E123

E126

C E

E133

E122 E121 E120

E117

E116

E115

E114

E130 E131

E132

E112

E111

E129

E127

B109 B110 B112 A130

C E

E137

E102G

E102L

C1E35

E102F E102E E102A

F129

F135

C E

E102J E102K

F104

E-1204

F171

F128

F134

C1E13

E108B

F122

C1E21

F171A F150

F101

F125

E102H

E107

E108

C F

F123

F151B

F102

F126

E102

E106

E108C

C F

F124

F151A

C1F7

C1E12

F168

F137A

C1F7

F121

F137

C1E11

C1F1

C1F19

C F

C1F2

C1F21

F136

F118

F117

F163

C1E15

C1F20

F103

C1E9

B144B

F116

C1F6

C F

F115

C1E16

B143

E134

C1E32

C1E10

B137

C F

F109

F108

C F

F146

F179

F131

C1F15

F105

F113 F114A

F127

F130

F103B

F114

F132

F151

F180

F149

C1E17

F119

F107

F106

F112 F155

F147

F152

C F

C F

F144

F138

F153

F138A

F145

F148

F110 F111 F139 F140 F141 F142 F156

C1F12

C F

F133

F157 F158 F159

C1F17

F143 F154

F120

E127A

F103A

A119A A121 A123 A125A

F100

TLT. TLT.

CORR.

SOILED

UTIL.

TLT.

CLEAN UTIL.

C O

R R

TLT.

CORR.

ST. TLT.

CORR.

CLEAN UTIL.

TLT.

SOILED

UTIL.

CORR.

TLT.

CORR.

TLT.

ST. TLT.

TLT.

CORR.

ELEC./

TELE./

MECH.

F.M.S. ENG.

DECONTAMINATION

PT. TLT. H. NURSE/

NOD

ST. TLT.

SOILED

CLEAN

UTIL.

C O

R R

MED.

PT. TLT/

SHR.

CORR.

CORR.

CORR.

CORR.

CORR.

ELEVATOR

LOBBY

ELEVATOR

LOBBY

EQ. STG.

F.M.S. ENG.

VEST.

VEST.

JAN.

ST. TLT.

STAIR

#10

F. TLT.

M. TLT.

CORR. STAIR

#4

ELEV

#11

ELEV

#10

ELEV

#9

TLT.

CORR.

C O

R R

C O

R R

C O

R R

CORR.

TLT.

CORR.

CORR.

C O

R R

E102BE102CE102D

C O

R R

CORR.

CORR.

CORR.

C O

R R

C O

R R

TLT.

ROOF BELOW

F

F

DN

UP

DN

F

F E

FE

C2E8

C2E7

C2E12

F210 F211 F212 F214 F215 F217 F235

F236 F239 F240 F267 F266 F265

F269

C2F23

F268 F264 F263

F210A C2F3

F204

C2F1

F201

F202

F206C F206D

C2F7

F203

C2E10

F224

C2F8

F206B F206A

F205

F242

F237

F206

F207

C2F20

E201

C2F20

F256

F245

F241

C F

F231

F223

C2F14 F257

F230

F232

F219

F238

F233

C2F16

F234

F243

F246

C F

E207

F209

C2F4

C2F6

F216

F208

C F

F209A

E204 C2E6

F247

F244

C2F17

F225

F228

E205A

C2E3

E226 E225 E223 E222

F218

C2F12

F222

C E

E212A

E224A E214

E213

E205

F221

C2F19

F222A F227

E208

E217

E211

E

C E

C F

F250

F255

C F

F226

E255

E216

C2E1

E220

F211A

F248

F249

C F

F220

E211A

E254

E256

C F

F213A

F213

E221

E219

E218

C F

E215

F271 F260

F270 F261

F262

C F

F273 F258

F272 F259

F229

F200

F274

F

E209A

F275

F213B

E203

E241

E239

E237

E236

C2E9

C2E11

E229

E227E235 E234 E233 E232 E230

E238

C2E16

C2E14

C2E17 E244

E240

E242 E243 E249

C2E18

E245

C E

E246 E247

E248 E250

E231

E228

C2E13

E251 E252

F251

F

F

F

F

E202

F227A

OPEN TO BELOW OPEN TO BELOW

TLT. ALCOVE

CORR.

CORR.

SOILED

UTIL.

ST. TLT.

CLEAN

DISPATCH

CORR.

CORR.

C O

R R

TLT.

ST. WK.

CORR.

C O

R R

C O

R R

TLT.

CLEAN

STORAGE

CORR.

JAN.

C O

R R

SURG.

SUPPLIES

TLT. TLT.

CORR.

SIGNAL

CORR.

CORR.

STERIL.

C O

R R

ALCOVE

ALCOVE

CORR.

SOILED

UTIL.

TLT.

TLT.

CORR.

TELE/ DATA

ELECTRICAL

CORR.

CORR.

TLT.

CORR.

C O

R R

CLEAN UTIL.

CORR.

CORR.

TLT.

TLT.

CORR.

ELEV

#11

ELEV

#10

ELEV

#9

STAIR

#11STAIR

#10

ELEC.

CLOSET

E212

CORR.

C O

R R

C O

R R

C O

R R

CORR.

CORR.

C O

R R

E305

F396

UP

DN

UP

DN

DN

#10

#11

#9

F315

F312.1

C3F3

E312

E306

E308

E310

E311

E329 E332 E333 E334 E338

E339

E340

E341

E336 E337

E331

E328

E327

E326

E324

E323 E322

E321

E319

C3E2

E320

E318 E317

C3F1

E316

E315 E314 E313

E300

E307

E304

C3F5

E309

F395

S T

R

F397

F300

F303

F302

F322

F304

F307

F

F305

F310 F309

F312

S T

R

F312.2 F311

E325

C E

C3E4

C E

E330

E335

F348 F346 F345 F343 F340 F339 F338 F337

C3F9

F349

F350

F321

F320

F317

F316

C F

F347 F344

F342 F341

F336

F324 F325 F326

F334

F333

F335

F332

F331

F327 F328 F329

F330

F323

F318

F314

C3F7

C F

F319

E A

F361 F359

F364 F360

F363 F362

F386

F372 F371

F375 F376 F377 F378

F382 F381 F380

F389

F391

F392

F393

F390

F385 F383

F358

F352 F353 F354 F355 F356

F357

F366 F367 F368

F370

F379

F369

F388

F398

F365

CORRIDOR

CBE3

MECHANICAL

ROOM

E003

PHARMACY

E001

MECHANICAL

ROOM

E003A

OFFICE

E002H

R.C.O. R&D

E002I

CLINICAL

RESEARCH

E002J

WORK ROOM

E002B

ELEC CLOSET

F001B

ELEC ROOM

E009

FA101

FA102

FX101

FX102

ELEC

F170

FA103

FX103

FX103

FA103

SC

1-

SC

1-

S C 1-10

S C 1-9

S C

1-11

S C

1-12

SC1-10

SC1-3

SC

1-

10SC

1-

REFRAC.

E210

DIRTY

E213

ELEC. CLOST

F252

RESTROOM

F253

FX103

FX103

FA103

FA103

S C

-5

S C

-7

SC2-7

SC2-6

SC2-5

SC2-6

MECHANICAL

PENTHOUSE

F399

WAITING

F300

ELEC.

F396

STAFF LOUNGE

E305

EXAM ROOM

F352

FA104

FX104

FX104

FA104

FA104

FX104

3S C 3-7S

C 3-8

S C 3-7S

C 3-8

RATEDENGINEERING.COM

MO LIC #2026005125

RATEDENGINEERING.COM

MO LIC #2026005125

RATEDENGINEERING.COM

MO LIC #2026005125

th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t

A

B

C

D

E

F

Veterans Health

Administration

VA FORM 08-6231

DRAWING TITLE PROJECT TITLE

LOCATION

DATE CHECKED DRAWN

PROJECT NUMBERCONSULTANTS:

DRAWING #

VA HEALTH CARE SYSTEM APPROVAL:

ARCHITECT:

SPUR DESIGN, LLC

312 SW 25TH STREET

Oklahoma City, OK 73109

(405) 842-6100

ARCH REG. NO. A-2012034754 EXP. 12/31/2026

ENGR REG. NO. E-2014031351 EXP. 12/31/2026

The information on this document is preliminary or incomplete, not for construction, recording purposes, or implementation.

FULLY SPRINKLERED

1 2 3 4 5 6 7 8 9

1 2 3 4 5 6 7 8 9

A

B

C

D

E

F

STAMP:

DRAWING NUMBER

BUILDING NUMBER

CIVIL/STRUCTURAL

H2B ENGINEERING

1225 NORTH LOOP WEST, SUITE 800

HOUSTON, TX 77008

(713) 864-2900

PHYSICAL SECURITY

FORCE PROTECT

4015 VITRUVIAN WAY, UNIT 1212

ADDISON, TX 75001

PHONE NUMBER

MECH/ELEC/PLUMB/TECH ENGINEER

SPUR DESIGN

312 SW 25TH STREET

OKLAHOMA CITY, OK 73109

(405) 842-6100

FIRE PROTECTION ENGINEER

RATED ENGINEERING

609 S. KELLY AVE., SUITE H2

EDMOND, OK 73003

(405) 210-5814

/9

/2

:4

:0

A

M

OVERALL REFERENCE PLANS -

BASEMENT, LEVELS 1, 2, AND 3

JCP 26 OF 73DBN

100% BID DOCUMENTS

INSTALL DEDICATED

PHARMACY AIR HANDLER

06/11/2026

589A4-25-102

HARRY S. TRUMAN VAMC

800 HOSPITAL DRIVE

COLUMBIA, MO 65201

F-101

32'16

64'0 32'16

64'0

N

3/64" = 1'-0"

BASEMENT - OVERALL REFERENCE PLAN1

N

3/64" = 1'-0"

LEVEL 1 - OVERALL REFERENCE PLAN2

N

3/64" = 1'-0"

LEVEL 2 - OVERALL REFERENCE PLAN3

N

3/64" = 1'-0"

LEVEL 3 - OVERALL REFERENCE PLAN4

06/11/2026

1. SYSTEM DESCRIPTION

A. THE EXISTING SYSTEM HEREIN IS A IN-BUILDING FIRE EMERGENCY VOICE/ALARM COMMUNICATION SYSTEM AS

DEFINED BY NFPA 72. UPON AUTOMATIC OR MANUAL ACTIVATION, THE SYSTEM MUST AUTOMATICALLY

COMMUNICATE EMERGENCY INFORMATION AS ORIGINALLY PROGRAMMED.

B. EXISTING SYSTEM MANUFACTURER IS SIEMENS, ALL NEW COMPONENTS SHALL BE MANUFACTURED BY

SIEMENS.

2. PURPOSE OF PLANS

A. THESE PLANS ARE INTENDED TO DEMONSTRATE CRITERIA, DEMONSTRATE CODE COMPLIANCE, AND SOLICIT

COMPETITIVE BIDS.

B. THESE PLANS ARE INTENDED TO DEMONSTRATE COORDINATED AND COMPLIANT LOCATIONS, TYPES, AND

SETTINGS OF INITIATING DEVICES, NOTIFICATION APPLIANCES, ANNUNCIATORS, CONTROL UNITS, AND

ASSOCIATED MAJOR COMPONENTS.

C. THESE PLANS ARE NOT INTENDED TO SHOW ALL CIRCUITS, COMPONENTS, ACCESSORIES, AND OTHER DETAILS

WHICH MUST BE DOCUMENTED IN THE CONTRACTOR’S SHOP DRAWINGS.

D. MODIFICATIONS MADE BY THE CONTRACTOR RESULTANT FROM COORDINATION, CALCULATIONS, OR CONTRACTOR ROUTING AND INSTALLATION PREFERENCES MUST BE PERFORMED AT NO ADDITIONAL COST TO

THE OWNER.

E. UNLESS SPECIFICALLY NOTED OTHERWISE, ALL MANUFACTURER AND MODEL DATA INDICATED HEREIN IS A

BASIS OF DESIGN AND IS NOT SOLE-SOURCED.

3. APPLICABLE CRITERIA

A. VA FIRE PROTECTION DESIGN MANUAL, NINTH EDITION, 2023

B. INTERNATIONAL BUILDING CODE, 2024

C. NFPA 13 STANDARD FOR THE INSTALLATION OF SPRINKLER SYSTEMS, 2025

D. NFPA 70 NATIONAL ELECTRICAL CODE, 2026

E. NFPA 72 NATIONAL FIRE ALARM AND SIGNALING CODE, 2025

F. NFPA 90A STANDARD FOR THE INSTALLATION OF AIR-CONDITIONING AND VENTILATION SYSTEMS, 2024 G. NFPA 96 STANDARD FOR VENTILATION CONTROL AND FIRE PROTECTION OF COMMERCIAL COOKING

OPERATIONS, 2024

H. NFPA 101 LIFE SAFETY CODE, 2024

4. SPECIFICATIONS

A. REFER TO PROJECT SPECIFICATIONS FOR ANY QUALIFICATIONS, SUBMITTAL, PRODUCT, INSTALLATION, TESTING, AND DOCUMENTATION CRITERIA.

B. SPECIFICATION CRITERIA STATED ON THESE PLANS IS INTENDED TO SUMMARIZE MAJOR SYSTEM CRITERIA;

REFER TO SPECIFICATIONS FOR ALL DETAILS.

C. IN THE EVENT OF A CONFLICT BETWEEN THESE DRAWINGS AND THE SPECIFICATIONS, THE FOLLOWING

CONFLICT RESOLUTION MUST BE FOLLOWED. IF THE CONFLICT IS OF EQUAL SPECIFICITY, THE MORE DEMANDING CRITERIA IS APPLICABLE. IF THE CONFLICT IS OF DIFFERING SPECIFICITY, THE MORE SPECIFIC

CRITERIA IS APPLICABLE.

5. SUPERVISING STATION COMMUNICATIONS

A. EXISTING - NOT MODIFIED BY THE SOW.

B. ALL FIRE ALARM CONTROL UNITS ARE EXISTING AND SUPERVISING METHOD IS NOT ALTERED BY THE FIRE

ALARM WORK REQUIRED FOR THIS PROJECT.

6. INITIATING DEVICES

A. THIS SYSTEM MUST SUPERVISE INITIATING DEVICES AS INDICATED ON THE PLANS.

B. SMOKE DETECTOR PLACEMENT RATIONALE - DURING CEILING DEMOLITION - EXISTING SMOKE DETECTION

SHALL BE PROTECTED DURING CONSTRUCTION. UPON INSTALLATION OF NEW CEILING SMOKE DETECTION SHALL BE REINSTALLED IN ACCORDANCE WITH NFPA 72, NFPA 101, AND THE VA FIRE PROTECTION DESIGN

MANUAL.

C. FIRE AND SMOKE DAMPERS - SMOKE DAMPERS ARE NOT INCLUDED WITHIN THIS SCOPE OF WORK, AS NO NEW DUCT PENETRATIONS OF SMOKE BARRIERS OR AIR TRANSFER OPENINGS IN SMOKE PARTITIONS ARE PROPOSED. REFER TO THE MECHANICAL DRAWINGS FOR LOCATIONS OF FIRE DAMPERS. FIRE DAMPERS SHALL BE PROVIDED WITH FUSIBLE LINK ACTUATION AND ARE NOT CONNECTED TO OR MONITORED BY THE FIRE

ALARM SYSTEM.

D. DUCT SMOKE DETECTOR PLACEMENT RATIONALE - ALL NEW AHU EQUIPMENT WHICH HAS A SUPPLY IN EXCESS OF 2000 CFM WILL BE PROVIDED WITH NEW DUCT DETECTORS IN ACCORDANCE WITH NFPA 90A. REFER TO

PLANS FOR ADDITIONAL INFORMATION ON NEW DUCT DETECTOR LOCATIONS.

7. NOTIFICATION

A. ALL OCCUPIABLE AREAS MUST ACHIEVE EITHER PUBLIC / PRIVATE MODE AUDIBILITY DEPENDING ON THE AREA

OF THE HOSPITAL IS IN THE AFFECTED NOTIFICATION ZONE. AREAS OF DEMOLITION WILL MAINTAIN THE SAME NOTIFICATION REQUIREMENTS POST CONSTRUCTION. THIS PROJECT DOES NOT MODIFY THE OCCUPANCY, NOTIFICATION REQUIREMENTS, OR PROGRAMMING OF FIRE ALARM VOICE EVACUATION SYSTEM.

B. VISUAL NOTIFICATION IS REQUIRED THROUGHOUT ALL PUBLIC AND COMMON WORK AREAS IN THE AFFECTED

NOTIFICATION ZONE.

8. CIRCUITS

A. CIRCUIT INTEGRITY AND SURVIVABILITY SHALL MATCH EXISTING CONDITIONS.

B. CIRCUIT CLASS B OR MORE RESILIENT IS REQUIRED.

C. FIRE ALARM SYSTEM CIRCUITS MUST BE PULLED SPLICE-FREE FROM DEVICE-TO DEVICE.

9. INSTALLATION

A. ALL COMPONENTS MUST BE COORDINATED WITH OTHER TRADES AND INSTALLED PARALLEL OR

PERPENDICULAR TO THE BUILDING STRUCTURE.

B. SYSTEM INSTALLATION MUST BE PERFORMED IN A NEAT, WORKMAN-LIKE MANNER.

C. CIRCUITS MAY ONLY BE PULLED INTO A CABINET WHEN NECESSARY FOR TERMINATION ON EQUIPMENT INSIDE

THAT CABINET.

D. DEVICES INSTALLED ON ACOUSTICAL CEILING TILES MUST BE INSTALLED USING CEILING BRIDGES.

E. THE LOCATION AND ORIENTATION OF PLFA, NPLFA, AND POWER CIRCUITS MUST BE PRE-PLANNED INSIDE THE

CABINET PRIOR TO ANY CABINET KNOCKOUTS BEING REMOVED. LOCATE POWER SUPPLY IN A LOCATION TO

MINIMIZE CONFLICT WITH PLFA AND NPLFA CIRCUITS.

F. AT SURGE PROTECTIVE DEVICES, THE PROTECTED AND UNPROTECTED CABLE MUST NOT BE IN CONTACT AND

MUST NOT BE INSTALLED IN THE SAME CONDUIT.

G. ALL INSTALLATION AND TESTING MUST COMPLY WITH THE APPLICABLE CRITERIA AND MANUFACTURER’S

INSTRUCTIONS.

H. THE SYSTEM MUST BE TURNED OVER TO THE OWNER IN LIKE-NEW CONDITION. THE CONTRACTOR MUST

REPLACE DAMAGED COMPONENTS WITH NEW COMPONENTS IF DAMAGED BEFORE TURNOVER.

SYMBOL MODIFIER

FIRE ALARM LEGEND

F

S

S

S

EXISTING MANUAL PULL STATION - TO REMAIN

EXISTING SPEAKER - TO REMAIN

EXISTING SPEAKER/STROBE - TO REMAIN

EXISTING STROBE - WALL MOUNT - TO REMAIN

EXISTING STROBE - CEILING MOUNT - TO REMAIN

EXISTING SMOKE DETECTOR - SPOT TYPE -

TO REMAIN OR RELOCATE

EXISTING SMOKE DETECTOR - DUCT TYPE -

TO REMAIN

SYMBOL MODIFIERS

ncd CANDELA RATING nW

C

WATT TAP

CEILING MOUNT

SA SUPPLY AIR DUCT

RA RETURN AIR DUCT

S

S

S

SPEAKER

SMOKE DETECTOR - SPOT TYPE

SMOKE DETECTOR - DUCT TYPE

F MANUAL PULL STATION

RATEDENGINEERING.COM

MO LIC #2026005125

RATEDENGINEERING.COM

MO LIC #2026005125

RATEDENGINEERING.COM

MO LIC #2026005125

th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t

A

B

C

D

E

F

Veterans Health

Administration

VA FORM 08-6231

DRAWING TITLE PROJECT TITLE

LOCATION

DATE CHECKED DRAWN

PROJECT NUMBERCONSULTANTS:

DRAWING #

VA HEALTH CARE SYSTEM APPROVAL:

ARCHITECT:

SPUR DESIGN, LLC

312 SW 25TH STREET

Oklahoma City, OK 73109

(405) 842-6100

ARCH REG. NO. A-2012034754 EXP. 12/31/2026

ENGR REG. NO. E-2014031351 EXP. 12/31/2026

The information on this document is preliminary or incomplete, not for construction, recording purposes, or implementation.

FULLY SPRINKLERED

1 2 3 4 5 6 7 8 9

1 2 3 4 5 6 7 8 9

A

B

C

D

E

F

STAMP:

DRAWING NUMBER

BUILDING NUMBER

CIVIL/STRUCTURAL

H2B ENGINEERING

1225 NORTH LOOP WEST, SUITE 800

HOUSTON, TX 77008

(713) 864-2900

PHYSICAL SECURITY

FORCE PROTECT

4015 VITRUVIAN WAY, UNIT 1212

ADDISON, TX 75001

PHONE NUMBER

MECH/ELEC/PLUMB/TECH ENGINEER

SPUR DESIGN

312 SW 25TH STREET

OKLAHOMA CITY, OK 73109

(405) 842-6100

FIRE PROTECTION ENGINEER

RATED ENGINEERING

609 S. KELLY AVE., SUITE H2

EDMOND, OK 73003

(405) 210-5814

/9

/2

:4

:0

A

M

FIRE ALARM NOTES MATRIX AND RISER

DIAGRAM

JCP 27 OF 73DBN

100% BID DOCUMENTS

INSTALL DEDICATED

PHARMACY AIR HANDLER

06/11/2026

589A4-25-102

HARRY S. TRUMAN VAMC

800 HOSPITAL DRIVE

COLUMBIA, MO 65201

FA001

FIRE ALARM GENERAL NOTES

S S

F

S

S

F

C S

S

C

C

S

S S

S

C

C

C

C

E001E

E001H

E001L

E001F

E001J

E001K

E002F

CONFERENCE

ROOM

E002E

PROGRAM

SUPPRT R&D

E002C

A.O. RAD

E002D

OFFICE

E002H

R.C.O. R&D

E002I

CLINICAL

RESEARCH

E002J

MFMR EXEC

OFFIC

E002K

WORK ROOM

E002B

CORRIDOR

CBE3

MECHANICAL

ROOM

E003

FREEZER

F030A

REFRIGERATOR

F030

CAMERA DARK

ROOM

F031

MICRO DARK

ROOM

F032

OFFICE

F033

ELEC CLOS.

F035

WORK ROOM

F002

OFFICE

F003

WORK ROOM

F006

OFFICE

F007

OFFICE

F008

OFFICE

F009

VESTIBULE

F009A

SHARED

OFFICE

F011

JANITOR

F036

STAIR #11

F307

JANITOR

F013

STORAGE

E001G

PHARMACY

E001

TELE / DATA

E006

ELEV MACHINE

ROOM

E007

WOMAN

TOILET

E010

MEN TOILET

E008

ELEC ROOM

E009

CORRIDOR

CBE2

STAGING

ROOM

E001D

E001C

STERILE IV

PREP

E001B

NARCOTIC

VAULT

E001A

CORRIDOR

CBE2

OFFICE

E002A

RESEARCH

SERVICE

CORRIDOR

E002

CORRIDOR

CBF1

CORRIDOR

CBE5

E005

ELEV

#10

ELEV

#09

ELEV

#11

E004CORRIDOR

CBE4

MECHANICAL

ROOM

E003A

CORRIDOR

CBF5

ELEC CLOSET

F001B

S

SA AHU-1

S

SA AHU-2

S

SA AHU-3

S

RA AHU-1

S

RA AHU-2

S

RA AHU-3

S

SA AHU-4

S

RA AHU-4

1 1

FIRE PROTECTION

LEGEND

THE AREA OF DEMOLITION IS SPECIFIC TO EXISTING

CEILING AND HVAC SYSTEM COMPONENTS, THE

FIRE PROTECTION SYSTEM COMPONENTS SHALL BE

PROTECTED TO THE MAXIMUM EXTENT POSSIBLE

AND REINSTALLED UPON COMPLETION OF NEW

CEILING AND HVAC SYSTEM COMPONENTS IN

ACCORDANCE WITH APPLICABLE CRITERIA

AREA NOT IN SCOPE

RATEDENGINEERING.COM

MO LIC #2026005125

RATEDENGINEERING.COM

MO LIC #2026005125

RATEDENGINEERING.COM

MO LIC #2026005125

th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t

A

B

C

D

E

F

Veterans Health

Administration

VA FORM 08-6231

DRAWING TITLE PROJECT TITLE

LOCATION

DATE CHECKED DRAWN

PROJECT NUMBERCONSULTANTS:

DRAWING #

VA HEALTH CARE SYSTEM APPROVAL:

ARCHITECT:

SPUR DESIGN, LLC

312 SW 25TH STREET

Oklahoma City, OK 73109

(405) 842-6100

ARCH REG. NO. A-2012034754 EXP. 12/31/2026

ENGR REG. NO. E-2014031351 EXP. 12/31/2026

The information on this document is preliminary or incomplete, not for construction, recording purposes, or implementation.

FULLY SPRINKLERED

1 2 3 4 5 6 7 8 9

1 2 3 4 5 6 7 8 9

A

B

C

D

E

F

STAMP:

DRAWING NUMBER

BUILDING NUMBER

CIVIL/STRUCTURAL

H2B ENGINEERING

1225 NORTH LOOP WEST, SUITE 800

HOUSTON, TX 77008

(713) 864-2900

PHYSICAL SECURITY

FORCE PROTECT

4015 VITRUVIAN WAY, UNIT 1212

ADDISON, TX 75001

PHONE NUMBER

MECH/ELEC/PLUMB/TECH ENGINEER

SPUR DESIGN

312 SW 25TH STREET

OKLAHOMA CITY, OK 73109

(405) 842-6100

FIRE PROTECTION ENGINEER

RATED ENGINEERING

609 S. KELLY AVE., SUITE H2

EDMOND, OK 73003

(405) 210-5814

/9

/2

:4

:0

A

M

FIRE ALARM DEMO PLAN - BASEMENT

JCP 28 OF 73DBN

100% BID DOCUMENTS

INSTALL DEDICATED

PHARMACY AIR HANDLER

06/11/2026

589A4-25-102

HARRY S. TRUMAN VAMC

800 HOSPITAL DRIVE

COLUMBIA, MO 65201

FA101

N

1/8" = 1'-0"

FIRE ALARM DEMO PLAN - BASEMENT1

0 4' 8' 16'

KEYNOTES

1 PROTECT CEILING MOUNT FIRE ALARM SYSTEM

COMPONENTS, WIRING, CONDUIT, AND EQUIPMENT AS

REQUIRED TO FACILITATE THE AHU/MECHANICAL

REPLACEMENT AND CEILING RECONFIGURATION.

S S

F

S

S

F

C S

S

C

C

S

S S

S

C

C

C

C

3 4 5 6 7 8 9

F

E

D

10 112

C

E.1

D.7

B

6.3 11.5

E001H

E001L

E001F

E001J

E001K

E002F

CONFERENCE

ROOM

E002E

PROGRAM

SUPPRT R&D

E002C

A.O. RAD

E002D

CORRIDOR

CBE3

MECHANICAL

ROOM

E003

MECHANICAL

ROOM

E003

FREEZER

F030A

REFRIGERATOR

F030

CAMERA DARK

ROOM

F031

MICRO DARK

ROOM

F032

ELEC CLOS.

F035

WORK ROOM

F002

OFFICE

F003

WORK ROOM

F006

OFFICE

F007

OFFICE

F008

OFFICE

F009

VESTIBULE

F009A

SHARED

OFFICE

F011

JANITOR

F036

STAIR #11

F307

JANITOR

F013

STORAGE

E001G

PHARMACY

E001

TELE / DATA

E006

ELEV MACHINE

ROOM

E007

WOMAN

TOILET

E010

MEN TOILET

E008

ELEC ROOM

E009

CORRIDOR

CBE2

STAGING

ROOM

E001D

E001C

STERILE IV

PREP

E001B

NARCOTIC

VAULT

E001A

CORRIDOR

CBE2

OFFICE

E002A

RESEARCH

SERVICE

CORRIDOR

E002

CORRIDOR

CBF1

CORRIDOR

CBE5

E005

ELEV

#10

ELEV

#09

ELEV

#11

E004CORRIDOR

CBE4

MECHANICAL

ROOM

E003A

OFFICE

E002H

R.C.O. R&D

E002I

CLINICAL

RESEARCH

E002J

MFMR EXEC

OFFIC

E002K

WORK ROOM

E002B

S

SA AHU-1

S

SA AHU-2

S

SA AHU-3

S

RA AHU-1

S

RA AHU-2

S

RA AHU-3

S

SA AHU-4

S

RA AHU-4

S

SA AHU-10

S

FIRE PROTECTION

LEGEND

AREA NOT IN SCOPE

RATEDENGINEERING.COM

MO LIC #2026005125

RATEDENGINEERING.COM

MO LIC #2026005125

RATEDENGINEERING.COM

MO LIC #2026005125

th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t

A

B

C

D

E

F

Veterans Health

Administration

VA FORM 08-6231

DRAWING TITLE PROJECT TITLE

LOCATION

DATE CHECKED DRAWN

PROJECT NUMBERCONSULTANTS:

DRAWING #

VA HEALTH CARE SYSTEM APPROVAL:

ARCHITECT:

SPUR DESIGN, LLC

312 SW 25TH STREET

Oklahoma City, OK 73109

(405) 842-6100

ARCH REG. NO. A-2012034754 EXP. 12/31/2026

ENGR REG. NO. E-2014031351 EXP. 12/31/2026

The information on this document is preliminary or incomplete, not for construction, recording purposes, or implementation.

FULLY SPRINKLERED

1 2 3 4 5 6 7 8 9

1 2 3 4 5 6 7 8 9

A

B

C

D

E

F

STAMP:

DRAWING NUMBER

BUILDING NUMBER

CIVIL/STRUCTURAL

H2B ENGINEERING

1225 NORTH LOOP WEST, SUITE 800

HOUSTON, TX 77008

(713) 864-2900

PHYSICAL SECURITY

FORCE PROTECT

4015 VITRUVIAN WAY, UNIT 1212

ADDISON, TX 75001

PHONE NUMBER

MECH/ELEC/PLUMB/TECH ENGINEER

SPUR DESIGN

312 SW 25TH STREET

OKLAHOMA CITY, OK 73109

(405) 842-6100

FIRE PROTECTION ENGINEER

RATED ENGINEERING

609 S. KELLY AVE., SUITE H2

EDMOND, OK 73003

(405) 210-5814

/9

/2

:4

:0

A

M

FIRE ALARM PLAN - BASEMENT

JCP 29 OF 73DBN

100% BID DOCUMENTS

INSTALL DEDICATED

PHARMACY AIR HANDLER

06/11/2026

589A4-25-102

HARRY S. TRUMAN VAMC

800 HOSPITAL DRIVE

COLUMBIA, MO 65201

FA102

N

1/8" = 1'-0"

FIRE ALARM PLAN - BASEMENT1

0 4' 8' 16'

KEYNOTES

1 REINSTALL EXISTING FIRE ALARM EQUIPMENT IN

ACCORDANCE WITH NFPA 72, NFPA 101, AND THE VA

FIRE PROTECTION DESIGN MANUAL.

S

S

F

F

C S S

S

S

F

F

C S S

E

D

10 11

E.1

D.7

11.5 1312

OFFICE

F175

STAIR

#11

ELEC

E170

TELE HEALTH

E141

E101 E142

PHARMACY

E141

TELEH.

E143

ENV. MGT.

F169

HOME

TELEHEALTH

F166

CORRIDOR

C1F22

SC1-9

SC1-10

E

D

10 11

E.1

D.7

11.5 1312

OFFICE

F175

STAIR

#11

ELEC

E170

TELE HEALTH

E141

E101 E142

PHARMACY

E141

TELEH.

E143

ENV. MGT.

F169

HOME

TELEHEALTH

F166

CORRIDOR

C1F22

SC1-9

SC1-10

CORRIDOR

C2E1

C O

R R

ID

O

R

C E

EXAM

E217

E216

E256

INTENR / RES.

SWAMP

E215

ELEC CLOSET

E252

RESTROOM

W253

REFRAC.

E210

DIRTY

E253

HAC

F275

CORRIDOR

C2F21

STAIR

#1

OFFICE

F255

CLEAN

STORAGE

E254

WORK

ROOM

E255

OFFICE

E209A

SC2-5

SC2-6

CORRIDOR

C2E1

C O

R R

ID

O

R

C E

EXAM

E217

E216

E256

INTENR / RES.

SWAMP

E215

ELEC CLOSET

E252

RESTROOM

W253

REFRAC.

E210

DIRTY

E253

HAC

F275

CORRIDOR

C2F21

STAIR

#1

OFFICE

F255

CLEAN

STORAGE

E254

WORK

ROOM

E255

OFFICE

E209A

SC2-5

SC2-6

FIRE PROTECTION

LEGEND

THE AREA OF DEMOLITION IS SPECIFIC TO EXISTING

CEILING AND HVAC SYSTEM COMPONENTS, THE

FIRE PROTECTION SYSTEM COMPONENTS SHALL BE

PROTECTED TO THE MAXIMUM EXTENT POSSIBLE

AND REINSTALLED UPON COMPLETION OF NEW

CEILING AND HVAC SYSTEM COMPONENTS IN

ACCORDANCE WITH APPLICABLE CRITERIA

AREA NOT IN SCOPE

RATEDENGINEERING.COM

MO LIC #2026005125

RATEDENGINEERING.COM

MO LIC #2026005125

RATEDENGINEERING.COM

MO LIC #2026005125

th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t

A

B

C

D

E

F

Veterans Health

Administration

VA FORM 08-6231

DRAWING TITLE PROJECT TITLE

LOCATION

DATE CHECKED DRAWN

PROJECT NUMBERCONSULTANTS:

DRAWING #

VA HEALTH CARE SYSTEM APPROVAL:

ARCHITECT:

SPUR DESIGN, LLC

312 SW 25TH STREET

Oklahoma City, OK 73109

(405) 842-6100

ARCH REG. NO. A-2012034754 EXP. 12/31/2026

ENGR REG. NO. E-2014031351 EXP. 12/31/2026

The information on this document is preliminary or incomplete, not for construction, recording purposes, or implementation.

FULLY SPRINKLERED

1 2 3 4 5 6 7 8 9

1 2 3 4 5 6 7 8 9

A

B

C

D

E

F

STAMP:

DRAWING NUMBER

BUILDING NUMBER

CIVIL/STRUCTURAL

H2B ENGINEERING

1225 NORTH LOOP WEST, SUITE 800

HOUSTON, TX 77008

(713) 864-2900

PHYSICAL SECURITY

FORCE PROTECT

4015 VITRUVIAN WAY, UNIT 1212

ADDISON, TX 75001

PHONE NUMBER

MECH/ELEC/PLUMB/TECH ENGINEER

SPUR DESIGN

312 SW 25TH STREET

OKLAHOMA CITY, OK 73109

(405) 842-6100

FIRE PROTECTION ENGINEER

RATED ENGINEERING

609 S. KELLY AVE., SUITE H2

EDMOND, OK 73003

(405) 210-5814

/9

/2

:4

:1

A

M

FIRE ALARM ENLARGED DEMOLITION AND

PLANS - LEVEL 1 AND 2

JCP 30 OF 73DBN

100% BID DOCUMENTS

INSTALL DEDICATED

PHARMACY AIR HANDLER

06/11/2026

589A4-25-102

HARRY S. TRUMAN VAMC

800 HOSPITAL DRIVE

COLUMBIA, MO 65201

FA103

N

1/8" = 1'-0"

FIRE ALARM DEMO PLAN - LEVEL 11

N

1/8" = 1'-0"

FIRE ALARM PLAN - LEVEL 12

N

1/8" = 1'-0"

FIRE ALARM DEMO PLAN - LEVEL 23

N

1/8" = 1'-0"

FIRE ALARM PLAN - LEVEL 24

0 4' 8' 16'

KEYNOTES

1 PROTECT CEILING MOUNT FIRE ALARM SYSTEM

COMPONENTS, WIRING, CONDUIT, AND EQUIPMENT AS

REQUIRED TO FACILITATE THE AHU/MECHANICAL

REPLACEMENT AND CEILING RECONFIGURATION.

2 REINSTALL EXISTING FIRE ALARM EQUIPMENT IN

ACCORDANCE WITH NFPA 72, NFPA 101, AND THE VA

FIRE PROTECTION DESIGN MANUAL.

MECHANICAL

PENTHOUSE

F399

INFUSION #5

F377

INFUSION #4

F376

INFUSION #6

F378

PRIVATE

INFUSION ROOM

F380

PRIVATE

INFUSION ROOM

F381

TOILET

F382

STAFF LOUNGE

E305

ELEC

F396

STAIR #11

ELEC

E304

BIOMED

E305A

STAFF LOCKERS

E306

STAFF LOCKERS

E308

STOR.

F397

CORRIDOR

C3F5

CORRIDOR

F379

S

SA AHU-11

S

SA AHU-12

FS

W

ACA-AHU-12

ACA-AHU-11

S

PATIENT

CONFERENCE

F352

CLINIC TRAILS

OFC

F353

SOILED

DISPATCH

F363

EXAM ROOM

F393

CORRIDOR

F358

WAITING

F300

H

G

PATIENT

CONFERENCE

F352

CLINIC TRAILS

OFC

F353

SOILED

DISPATCH

F363

EXAM ROOM

F393

CORRIDOR

F358

WAITING

F300

FIRE PROTECTION

LEGEND

THE AREA OF DEMOLITION IS SPECIFIC TO EXISTING

CEILING AND HVAC SYSTEM COMPONENTS, THE

FIRE PROTECTION SYSTEM COMPONENTS SHALL BE

PROTECTED TO THE MAXIMUM EXTENT POSSIBLE

AND REINSTALLED UPON COMPLETION OF NEW

CEILING AND HVAC SYSTEM COMPONENTS IN

ACCORDANCE WITH APPLICABLE CRITERIA

AREA NOT IN SCOPE

RATEDENGINEERING.COM

MO LIC #2026005125

RATEDENGINEERING.COM

MO LIC #2026005125

RATEDENGINEERING.COM

MO LIC #2026005125

th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t

A

B

C

D

E

F

Veterans Health

Administration

VA FORM 08-6231

DRAWING TITLE PROJECT TITLE

LOCATION

DATE CHECKED DRAWN

PROJECT NUMBERCONSULTANTS:

DRAWING #

VA HEALTH CARE SYSTEM APPROVAL:

ARCHITECT:

SPUR DESIGN, LLC

312 SW 25TH STREET

Oklahoma City, OK 73109

(405) 842-6100

ARCH REG. NO. A-2012034754 EXP. 12/31/2026

ENGR REG. NO. E-2014031351 EXP. 12/31/2026

The information on this document is preliminary or incomplete, not for construction, recording purposes, or implementation.

FULLY SPRINKLERED

1 2 3 4 5 6 7 8 9

1 2 3 4 5 6 7 8 9

A

B

C

D

E

F

STAMP:

DRAWING NUMBER

BUILDING NUMBER

CIVIL/STRUCTURAL

H2B ENGINEERING

1225 NORTH LOOP WEST, SUITE 800

HOUSTON, TX 77008

(713) 864-2900

PHYSICAL SECURITY

FORCE PROTECT

4015 VITRUVIAN WAY, UNIT 1212

ADDISON, TX 75001

PHONE NUMBER

MECH/ELEC/PLUMB/TECH ENGINEER

SPUR DESIGN

312 SW 25TH STREET

OKLAHOMA CITY, OK 73109

(405) 842-6100

FIRE PROTECTION ENGINEER

RATED ENGINEERING

609 S. KELLY AVE., SUITE H2

EDMOND, OK 73003

(405) 210-5814

/9

/2

:4

:1

A

M

FIRE ALARM DEMOLITION AND PLANS -

LEVEL 3

JCP 31 OF 73DBN

100% BID DOCUMENTS

INSTALL DEDICATED

PHARMACY AIR HANDLER

06/11/2026

589A4-25-102

HARRY S. TRUMAN VAMC

800 HOSPITAL DRIVE

COLUMBIA, MO 65201

FA104

N

1/8" = 1'-0"

FIRE ALARM PLAN - LEVEL 31

N

1/8" = 1'-0"

FIRE ALARM DEMO PLAN - LEVEL 32

N

1/8" = 1'-0"

FIRE ALARM PLAN - LEVEL 33

0 4' 8' 16'

No. REVISION DESCRIPTION DATE

KEYNOTES

1 MECHANICAL PENTHOUSE F399 IS AN EXTENSION OF

SMOKE COMPARTMENT 3.7

2' - 0"

2' - 0"

DETAIL NOTES:

1. DETAIL TYPICAL FOR ALL CEILING-MOUNT FIRE ALARM DEVICES,

NOT JUST THE INDICATED SPEAKER/STROBE.

2. INSTALL FIRE ALARM DEVICES IN 2' X 4' AND 2' X 2' CEILING TILES

AS INDICATED ABOVE.

3. ALIGN FIRE ALARM DEVICES AMONGST ADJACENT CEILING TILES

WHERE IN THE SAME FIELD OF VIEW INCLUDING THROUGH OPEN

DOORS AND GLASS PARTITIONS.

4. WHERE FIRE ALARM DEVICES ARE INSTALLED IN CEILINGS OTHER

THAN 2' X 4' AND 2' X 2' CEILING TILES, ALIGN WITH LIGHTS,

DIFFUSERS, AND ARCHITECTURAL FEATURES.

1' - 0"

1' - 0"

FINISHED FLOOR

FIRE ALARM

CONTROL UNIT

OR

TRANSPONDER

OR

NETWORK NODE

BATTERY

CABINET

M A

X

REMOTE

POWER

SUPPLY

M A

X

DOCUMENT

CABINET

M A

X

NOTES:

1. THIS DETAIL IS DIAGRAMMATIC. PANELS MAY BE INSTALLED ABOVE AND BELOW EACH OTHER WHERE NECESSARY DUE TO LIMITED WALL SPACE.

WALL

REMOTE

POWER

SUPPLY

LOCAL

OPERATORS

CONSOLE

T O

L O

C C

O N

T R

O L S

M

IC

M

IN

M A

X

F

T

O

T O

H A

N D

L E

FIRE

ALARM

ANNUNCIATOR

T O

T O

P O

F L

C D

D

IS

P L A

Y

RATEDENGINEERING.COM

MO LIC #2026005125

RATEDENGINEERING.COM

MO LIC #2026005125

RATEDENGINEERING.COM

MO LIC #2026005125

th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t

A

B

C

D

E

F

Veterans Health

Administration

VA FORM 08-6231

DRAWING TITLE PROJECT TITLE

LOCATION

DATE CHECKED DRAWN

PROJECT NUMBERCONSULTANTS:

DRAWING #

VA HEALTH CARE SYSTEM APPROVAL:

ARCHITECT:

SPUR DESIGN, LLC

312 SW 25TH STREET

Oklahoma City, OK 73109

(405) 842-6100

ARCH REG. NO. A-2012034754 EXP. 12/31/2026

ENGR REG. NO. E-2014031351 EXP. 12/31/2026

The information on this document is preliminary or incomplete, not for construction, recording purposes, or implementation.

FULLY SPRINKLERED

1 2 3 4 5 6 7 8 9

1 2 3 4 5 6 7 8 9

A

B

C

D

E

F

STAMP:

DRAWING NUMBER

BUILDING NUMBER

CIVIL/STRUCTURAL

H2B ENGINEERING

1225 NORTH LOOP WEST, SUITE 800

HOUSTON, TX 77008

(713) 864-2900

PHYSICAL SECURITY

FORCE PROTECT

4015 VITRUVIAN WAY, UNIT 1212

ADDISON, TX 75001

PHONE NUMBER

MECH/ELEC/PLUMB/TECH ENGINEER

SPUR DESIGN

312 SW 25TH STREET

OKLAHOMA CITY, OK 73109

(405) 842-6100

FIRE PROTECTION ENGINEER

RATED ENGINEERING

609 S. KELLY AVE., SUITE H2

EDMOND, OK 73003

(405) 210-5814

/9

/2

:4

:1

A

M

FIRE ALARM DETAILS

JCP 32 OF 73DBN

100% BID DOCUMENTS

INSTALL DEDICATED

PHARMACY AIR HANDLER

06/11/2026

589A4-25-102

HARRY S. TRUMAN VAMC

800 HOSPITAL DRIVE

COLUMBIA, MO 65201

FA501

NTS

FIRE ALARM DEVICE CEILING TILE INSTALLATION DETAIL2

NTS

FIRE ALARM EQUIPMENT MOUNTING HEIGHTS1

1. SYSTEM DESCRIPTION

A. THE AUTOMATIC FIRE SUPPRESSION SYSTEMS IN THIS BUILDING AFFECTED BY THE

SCOPE OF WORK IS: WET PIPE SPRINKLER SYSTEMS.

2. PURPOSE OF PLANS

A. THESE PLANS ARE INTENDED TO DEMONSTRATE CRITERIA, DEMONSTRATE CODE

COMPLIANCE, AND SOLICIT COMPETITIVE BIDS.

B. THESE PLANS ARE INTENDED TO DEMONSTRATE A COORDINATED PROOF-OF-

CONCEPT. THE CONTRACTOR MAY DEVIATE FROM THE LAYOUT INDICATED HEREIN

BUT MUST MAINTAIN COMPLIANCE WITH THE APPLICABLE CRITERIA, PROJECT

SPECIFICATIONS, AND SPECIFIC NOTES AND KEYNOTES ON THESE DRAWINGS.

C. THESE PLANS ARE NOT INTENDED TO BE USED FOR CONSTRUCTION.

D. MODIFICATIONS MADE BY THE CONTRACTOR RESULTANT FROM COORDINATION,

CALCULATIONS, OR CONTRACTOR ROUTING AND INSTALLATION PREFERENCES MUST

BE PERFORMED AT NO ADDITIONAL COST TO THE OWNER.

E. THESE PLANS ARE NOT INTENDED TO SHOW ALL HANGERS, COMPONENTS,

ACCESSORIES, AND OTHER DETAILS WHICH WILL BE DOCUMENTED IN THE

CONTRACTOR'S SHOP DRAWINGS, CALCULATIONS, AND PRODUCT DATA SELECTIONS.

F. UNLESS SPECIFICALLY NOTED OTHERWISE, ALL MANUFACTURER AND MODEL DATA

INDICATED HEREIN IS A BASIS OF DESIGN AND IS NOT SOLE-SOURCED. THE

CONTRACTOR MAY SELECT THEIR OWN MANUFACTURER AND MODEL, EXCEPT WHERE

EXPLICITLY NOTED OTHERWISE.

G. FITTING AND COUPLING TYPE INDICATED ON PLANS IS NOT CONTRACTUALLY BINDING;

REFER TO SPECIFICATIONS FOR FITTING AND COUPLING REQUIREMENTS.

H. AS THE CONTRACTOR REVISES AND COORDINATES THEIR LAYOUT WITH OTHER

TRADES, THE NUMBER OF TRAPPED SECTIONS MUST BE AS MINIMAL AS FEASIBLE.

3. APPLICABLE CRITERIA

A. VA FIRE PROTECTION DESIGN MANUAL, NINTH EDITION, 2023

B. INTERNATIONAL BUILDING CODE, 2024

C. NFPA 13 STANDARD FOR THE INSTALLATION OF SPRINKLER SYSTEMS, 2025

D. NFPA 70 NATIONAL ELECTRICAL CODE, 2026

E. NFPA 72 NATIONAL FIRE ALARM AND SIGNALING CODE, 2025

F. NFPA 90A STANDARD FOR THE INSTALLATION OF AIR-CONDITIONING AND VENTILATION

SYSTEMS, 2024

G. NFPA 96 STANDARD FOR VENTILATION CONTROL AND FIRE PROTECTION OF

COMMERCIAL COOKING OPERATIONS, 2024

H. NFPA 101 LIFE SAFETY CODE, 2024

4. SPECIFICATIONS

A. REFER TO PROJECT SPECIFICATIONS FOR MANY QUALIFICATIONS, SUBMITTAL,

PRODUCT, INSTALLATION, TESTING, AND DOCUMENTATION CRITERIA. THE PROJECT

SPECIFICATIONS ARE WRITTEN WITH INTENT AND WILL BE ENFORCED.

B. SPECIFICATION CRITERIA STATED ON THESE PLANS IS INTENDED TO SUMMARIZE

MAJOR SYSTEM CRITERIA. REFER TO SPECIFICATIONS FOR ALL DETAILS.

5. DESIGN

A. EXISTING FIRE SPRINKLER SYSTEM SHALL BE PROTETED AND MAINTAINED DURING

DEMOLITION OF CEILING AND INSTALLATION OF NEW HVAC AND CEILING EQUIPMENT.

ANY MODIFICATIONS MADE TO ACCOMODATE HVAC DESIGN WHICH IMPACT THE FIRE

SPRINKLER DESIGN SHALL BE ADDRESSED IN ACCORDANCE WITH APPLICABLE

CRITERIA. REFERENCE PLANS FOR ADDITIONAL INFORMATION ON FLOORPLAN

MODIFICATIONS AND ANTICIPATED CEILING DEMOLITION AREAS.

6. INSTALLATION

A. ALL COMPONENTS MUST BE COORDINATED WITH OTHER TRADES AND INSTALLED

PARALLEL OR PERPINDICULAR TO THE BUILDING STRUCTURE.

B. SYSTEM INSTALLATION MUST BE PERFORMED IN A NEAT, WORKMAN-LIKE MANNER.

C. ALL INSTALLATION AND TESTING MUST COMPLY WITH THE APPLICABLE CRITERIA AND

MANUFACTURER'S INSTRUCTIONS.

D. THE SYSTEM MUST BE TURNED OVER TO THE OWNER IN LIKE-NEW CONDITION. THE

CONTRACTOR MUST REPLACE DAMAGED COMPONENTS WITH NEW COMPONENTS IF

DAMAGED BEFORE TURNOVER.

E. ALL EXPOSED SPINKLER PIPING, NEW OR EXISTING, TO BE PAINTED RED.

RATEDENGINEERING.COM

MO LIC #2026005125

RATEDENGINEERING.COM

MO LIC #2026005125

RATEDENGINEERING.COM

MO LIC #2026005125

th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t

A

B

C

D

E

F

Veterans Health

Administration

VA FORM 08-6231

DRAWING TITLE PROJECT TITLE

LOCATION

DATE CHECKED DRAWN

PROJECT NUMBERCONSULTANTS:

DRAWING #

VA HEALTH CARE SYSTEM APPROVAL:

ARCHITECT:

SPUR DESIGN, LLC

312 SW 25TH STREET

Oklahoma City, OK 73109

(405) 842-6100

ARCH REG. NO. A-2012034754 EXP. 12/31/2026

ENGR REG. NO. E-2014031351 EXP. 12/31/2026

The information on this document is preliminary or incomplete, not for construction, recording purposes, or implementation.

FULLY SPRINKLERED

1 2 3 4 5 6 7 8 9

1 2 3 4 5 6 7 8 9

A

B

C

D

E

F

STAMP:

DRAWING NUMBER

BUILDING NUMBER

CIVIL/STRUCTURAL

H2B ENGINEERING

1225 NORTH LOOP WEST, SUITE 800

HOUSTON, TX 77008

(713) 864-2900

PHYSICAL SECURITY

FORCE PROTECT

4015 VITRUVIAN WAY, UNIT 1212

ADDISON, TX 75001

PHONE NUMBER

MECH/ELEC/PLUMB/TECH ENGINEER

SPUR DESIGN

312 SW 25TH STREET

OKLAHOMA CITY, OK 73109

(405) 842-6100

FIRE PROTECTION ENGINEER

RATED ENGINEERING

609 S. KELLY AVE., SUITE H2

EDMOND, OK 73003

(405)…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .