This addendum provides revisions to construction drawings for Electronic Health Records Management Infrastructure Upgrades project 589A7-21-700 at the Veterans Affairs Medical Center in Wichita, Kansas. The revisions include changes to site plans, communications diagrams, and architectural drawings for multiple buildings. On the site plans, revisions specify that conduit and manholes for new AT&T fiber and telephone cables will be contractor-provided and installed. Interior changes shown on architectural drawings modify existing walls to become smoke-rated and relocate electrical panels and equipment for new telecommunications rooms. The addendum provides updated drawings to reflect revisions to the construction project for infrastructure upgrades at the VA medical center.
View the file
Other files for this federal contract opportunity
Show all 50
Z2DA--589A7-21-700 EHRM Infrastructure Upgrades has more files on GovTribe.
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
CVE Verified Service-Disabled Veteran-Owned Small Business
TRIPLE C – THE A&E GROUP
OUR REASONABLE SERVICE - TO PROVIDE YOU WITH EXEMPLARY SERVICE
410 Grand Avenue, Suite 201C � Laramie, Wyoming 82070 � Telephone: (307) 460-2054 � Fax: (307) 460-2053
Addendum
Project: 589A7-21-700/EHRM INFRASTRUCTURE
UPGRADES, Wichita VAMC
Subject: Addendum No. 1
Date: 01/20/2022
Revisions:
1. Site
a. Site conduit and handholes for new AT&T WAN fiber and telephone copper cable shall be contractor provided/contractor installed (CPCI). AT&T will pull new fiber and copper cable after conduit and manholes are commissioned, inspected and accepted by the VA.
Fiber will be tested, terminated and placed into use by AT&T.
b. Contractor shall provide new conduit/cable tray for all ISP (Inside Plant) fiber.
2. Building 01
a. Sheet A-402: Added Key Notes 7, 8 and 9 to clarify existing conditions and demolition scope on Level 4. Identified existing ductwork, electrical disconnect and lightning protection to be relocated.
3. Building 03
a. Sheet A-401: Added Key Notes 8, 9 and 10 to clarify existing conditions and demolition scope on Level 0. Identified existing slabs, electrical panels and utilities above.
b. Sheet A-402: Added Key Note 10 to clarify existing conditions and identify existing slope/ramp on Level 1. Contractor shall coordinate with new construction.
4. Building 19
a. Sheet A-403: Added Key Note 7 to clarify existing conditions and identify existing slope/ramp on Level 2. Contractor shall coordinate with new construction.
Meeting Agenda
BLDG/Sheet Number Revision Description of / Reason for Change
SITE/AS100 ADD 01 Revised AT&T fiber/copper conduit and manholes to be CPCI.
SITE/AS100 ADD 01 All ISP fiber routes shall be new conduit/cable tray, CPCI.
SITE/T-602 ADD 01 Revised AT&T fiber/copper conduit and manholes to be CPCI.
SITE/T-602 ADD 01 All ISP fiber routes shall be new conduit/cable tray, CPCI.
B01/A-402 ADD 01 Added KN 7, 8 and 9 to clarify demolition scope.
B03/A-401 ADD 01 Added KN 8, 9 and 10 to clarify demolition scope.
B03/A-402 ADD 01 Added KN 10 to identify existing slope/ramp.
B19/A-403 ADD 01 Added KN 7 to identify existing slope/ramp.
End of Addenda
Attachments: SITE.AS100.ADD01.20220120.pdf
SITE.T-602.ADD01.20220120.pdf
B01.A-402.ADD01.20220120.pdf
B03.A-401.ADD01.20220120.pdf
B03.A-402.ADD01.20220120.pdf
B19.A-403.ADD01.20220120.pdf
F A
C P
NEW PULL BOX.
STAIR 1
ELEV. 1
ELEV.
EQUIP.
HALL
BOILER
ROOM
EXISTING CONDUIT
EXISTING ROUTE WITHIN
BUILDING
EXISTING BUILDING
NEW FIBER IN EXISTING CONDUIT -
MAIN ROUTE
EXISTING ROUTE WITHIN BUILDING -
NEEDS VERIFICATION
NEW FIBER IN NEW CONDUIT / TRAY -
MAIN ROUTE
EXISTING ELECTRICAL
CONDUIT
SERVICE PROVIDER A -
AT&T
SERVICE PROVIDER B -
COX COMM.
OMAR B
RADLEY D
RIVE
KELLOGG DRIVE
E D
G E
M O
O R
S T
R E
E T
B L E
C K
L E
Y D
R
IV
E
WATERMAN STREET
B5
B5B
B7
B6
B21
B16
B12B13B20
B10 B11
B60
B4 B1B3
B29
B62
B26
B61
B19 B2
B1C
B1B
B34
B59
B1A
COMM MANHOLE - 5
COMM MANHOLE - 3
COMM MANHOLE - 4
COMM MANHOLE - 2
COMM MANHOLE - 6
COMM MANHOLE - 9
COMM MANHOLE - 10
SOUTH END STEAM
TUNNEL / B13
COMM MANHOLE - 11
COMM
HANDHOLE - H1
B58
COMM MANHOLE - 1
COMM
MANHOLE - 7
COMM MANHOLE - 12
COMM MANHOLE - 13
COMM
MANHOLE - 8
T-604
C1
T-603
F5
T-603
C5
T-603
C1
T-606
C1
T-606
F1
T-604
F1
T-605
C1
T-605
C5
T-604
F5
(N) COMM
HANDHOLE - T2
(N) COMM HANDHOLE -
AT&T 1
(N) COMM HANDHOLE -
AT&T 2
T-605
F1
T-604
C5
T-603
F1
T-605
F5
(N) COMM
HANDHOLE -
T1
FUTURE CHILLER
LOCATION
ELEC MANHOLE
(N) COMM HANDHOLE -
AT&T 3
EXISTING PERIMETER
FENCE
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
GENERAL NOTES
KEYNOTES
TRIPLE C - The A/E Group
4625 Lindell Blvd., 2nd Floor, 2064
St. Louis, MO 63108
MAT PERKINS
314-372-0067
B
IM
/5
A
-2
-7
E H
R M
I n fr a s tr u c tu re U p g ra d e s
W ic h it a /5
A
-2
-7
E H
R M
W ic h it a
S it e
A
R C
H .r v t
/1
/2
:2
:5
P
M
AS100
SITE PLAN - NEW COMMUNICATIONS BASE BID 589A7-21-700
SITE
06/30/21 M. Perkins K. Struble
ISSUED FOR
CONSTRUCTION
EHRM INFRASTRUCTURE
UPGRADES
5500 E. KELLOGG, WICHITA, KANSAS 67218-1607
0 30'-0" 60'-0" 120'-0"
1 EXISTING FIBER FEED TO REMAIN
2 INSTALL NEW FIBER - FEED THROUGH EXISTING CONDUIT
3 INSTALL NEW FIBER AND NEW CONDUIT OR CABLE TRAY
4 DRILL EXISTING MANHOLE CONNECT 4" PVC CONDUIT
5 CONSTRUCT TWO (2) 4" PVC CONDUIT - TRENCH AND REPLACE EXISTING
LANDSCAPE - MATCH EXISTING, SEE DETAIL B4, SHEET AS501.
DIRECTIONAL BORE AT SIDEWALK, CURB AND ASPHALT. PROVIDE FIBER
OPTIC CABLE PER SHEET T-602
6 CONSTRUCT 24"X36"X36" COMM PULLBOX, OLDCASTLE MODEL
DURALITE 2436 (TRAFFIC RATED - TIER 22) OR APPROVED EQUAL - SEE
DETAILS E1, B7 AND D7, SHEET AS501
7 PROVIDE 30"X60"X36" COMM PULLBOX, OLDCASTLE MODEL FRP 306.
AT&T WILL PULL NEW FIBER AND COPPER CABLES AFTER CONTRACTOR
PROVIDES INFRASTRUCTURE.
8 PROVIDE 48"X96"X48" COMM PULLBOX, OLDCASTLE MODEL FRP 4896.
AT&T WILL PULL NEW FIBER AND COPPER CABLES AFTER CONTRACTOR
PROVIDES INFRASTRUCTURE.
9 SEE BUILDING 34 SHEET T-101 FOR CONTINUATION
10 EXISTING TREE TO REMAIN - PROTECT IN PLACE
11 CONSTRUCT GROUND ROD SYSTEM AND BOND BAR - SEE DETAIL F7,
SHEET AS501
12 PROVIDE TWO (2) 4" PVC CONDUIT. AT&T WILL PULL NEW FIBER AND
COPPER CABLES AFTER CONTRACTOR PROVIDES INFRASTRUCTURE.
13 CONSTRUCT TWO (2) 5" PVC CONDUIT - TRENCH AND REPLACE EXISTING
LANDSCAPE - MATCH EXISTING, SEE DETAIL B4, SHEET AS501.
DIRECTIONAL BORE AT SIDEWALK, CURB AND ASPHALT. PROVIDE FIBER
OPTIC CABLE PER SHEET T-602, SEE BUILDING PLANS 5, 5B SHEET T-101
FOR ADDITIONAL INFORMATION
14 CONSTRUCT HANDHOLE AND CHASE PER B34 PLANS, SHEET A-404
LINETYPE
1" = 60'-0" F1
SITE PLAN - NEW COMMUNICATIONS BASE BID
NOTE
BASE BID: FIBER HOME RUNS FROM EACH BUILDING BACK TO B34.
PROVIDE 100' EXTRA SLACK EACH FIBER OPTIC CABLE FOR FUTURE
EXTENSION TO NEW SERVER ROOM. EXTEND FIBER FROM B34 TO B19
FOR TERMINATION AT EXISTING SERVER ROOM. FUTURE SCOPE WILL
REMOVE THIS B34 TO B19 EXTENSION. SEE SITE PLANS FOR
ADDITIONAL INFORMATION.
NOTE
AT&T/CHC contact information:
Janice Bowers CHC Consulting
(785) 806-2828 jbowers@chcconsulting.com
Jason Edwards Mgr. Osp Plng & Engrg Design Wichita, KS 316-268-2008 je1682@att.com
COX Communications contact information:
Bilal H. Batroukh, PMP Project Manager, Development T-Mobile Direct 425.436.4199 | Mobile 708.253.2018| bilal.batroukh1@t-mobile.com
Revisions: Date:
Addendum 1 01/20/2022
BLDG 1
BLDG 1A
BLDG 3
BLDG 2
BLDG 26
BLDG 61
BLDG 29
BLDG 62
BLDG 19
BLDG 34
BLDG 4
BLDG 59
BLDG 60
BLDG 20 BLDG 13 BLDG 12
BLDG 16BLDG 11S
T
E A
M T
U N
N E
L
BLDG 21
BLDG 6
BLDG 5
BLDG 5B
BLDG 7
MH
MH
MH
MH
MH
MH
MH
MH
MH
MH
MH
MH
MH
HALLWAY
3X12F
OS2-10GB
1X24F
OS2-10GB
7X24F
OS2-10GB
HH
T2
3X12F
OS2-10GB
HH
T1
MH
AT&T 1
HH
AT&T 3
MH
AT&T 2
HH
H1
SERVICE
PROVIDER B
COX COMM.
SERVICE
PROVIDER B
COX COMM.
SERVICE
PROVIDER B
COX COMM.
SERVICE
PROVIDER A
AT&T
SERVICE
PROVIDER A
AT&T
1X12F
OM4-10GB
4X12F
OM4-10GB
2X24F
OM4-10GB
6X24F
OM4-10GB
4X12F
OM4-10GB
6X24F
OM4-10GB
2X24F
OM4-10GB
3X24F
OS2-10GB
1X12F OS2-10GB
1X12F OS2-10GB
3X12F OS2-10GB
1X12F OS2-10GB
2X12F OS2-10GB
5X12F OS2-10GB
1X12F
OM4-10GB
5X12F OS2-10GB
1X12F OM4-10GB
1X12F
OM4-10GB
5X24F
OM4-10GB
7X24F
OM4-10GB
1X12F OS2-10GB
1X12F
OS2-10GB
1X12F
OS2-10GB
1X24F
OS2-10GB
1X12F
OS2-10GB
8X24F
OS2-10GB
4X12F
OS2-10GB
8X24F
OS2-10GB
4X12F
OS2-10GB
8X24F
OS2-10GB
1X24F
OM4-10GB
4X12F
OS2-10GB
8X24F
OS2-10GB
5X12F OM4-GB
14X24F OM4-10GB
4X12F OS2-10GB
8X24F OS2-10GB
BASE BID: FIBER HOME RUNS FROM EACH BUILDING BACK THROUGH B34 AND
TERMINATING IN B19. PROVIDE 100' EXTRA SLACK EACH FIBER OPTIC CABLE
FOR FUTURE EXTENSION TO NEW SERVER ROOM. EXTEND FIBER FROM SLACK
LOOPS IN B34 TO B19 FOR TERMINATION AT EXISTING SERVER ROOM. FUTURE
SCOPE WILL REMOVE THIS B34 TO B19 EXTENSION. SEE B34 TECHNOLOGY
PLANS AND SITE PLANS FOR ADDITIONAL INFORMATION.
DEDUCT ALTERNATE: FIBER HOMERUNS FROM EACH BUILDING BACK TO B19
SERVER ROOMS (001). SEE SITE PLANS FOR ADDITIONAL INFORMATION.
CONTRACTOR
PROVIDED/CONTRACTOR
INSTALLED MANHOLES AND
CONDUIT (2X 4" PVC) AND
CABLE TRAY.
AT&T WILL PULL NEW FIBER
AND COPPER CABLE. AT&T
FIBER WILL BE TESTED,
TERMINATED AND PLACED
INTO USE BY AT&T.
CONTRACTOR
PROVIDED/CONTRACTOR
CONDUIT AND CABLE TRAY
COX WILL PULL NEW FIBER
AND COPPER CABLE. COX
FIBER WILL BE TESTED
TERMINATED, AND PLACED
INTO USE BY COX.
EXISTING ROUTE WITHIN
BUILDING
EXISTING BUILDING
NEW FIBER IN EXISTING CONDUIT -
MAIN ROUTE
NEW FIBER IN NEW CONDUIT / TRAY -
MAIN ROUTE
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
GENERAL NOTES
KEYNOTES
TRIPLE C - The A/E Group
4625 Lindell Blvd., 2nd Floor, 2064
St. Louis, MO 63108
MAT PERKINS
314-372-0067
B
IM
/5
A
-2
-7
E H
R M
I n fr a s tr u c tu re U p g ra d e s
W ic h it a /5
A
-2
-7
E H
R M
W ic h it a
S it e
A
R C
H .r v t
/1
/2
:2
:2
P
M
T-602
SITE PLAN - COMMUNICATIONS ONE-LINE
DIAGRAM - NEW BASE BID
589A7-21-700
SITE
06/30/21 M. PERKINS K. STRUBLE
ISSUED FOR
CONSTRUCTION
EHRM INFRASTRUCTURE
UPGRADES
5500 E. KELLOGG, WICHITA, KANSAS 67218-1607
1/2" = 1'-0" F1
COMMUNICATIONS ONE-LINE DIAGRAM NEW
NOT USED
Revisions: Date:
Addendum 1 01/20/2022
UP
SHEET SYMBOL LEGEND
KEYNOTES
GENERAL NOTES
EXISTING CONSTRUCTION TO REMAIN
EXISTING CONSTRUCTION TO BE DEMOLISHED
NEW CONSTRUCTION, WITH PARTITION TYPE
A
A. SEE GENERAL NOTES AND PLANS FOR TYPICAL GENERAL
PROJECT REQUIREMENTS AND PROJECT LOCATION DRAWINGS.
B. SEE INTERIOR FINISH DRAWINGS FOR ADDITIONAL FINISHES
INFORMATION.
C. SEE MECHANICAL AND ELECTRICAL DRAWINGS FOR ADDITIONAL
SYSTEMS INFORMATION.
D. NEW IT CLOSETS SHALL BE SMOKE RATED AND COMPLY WITH
THE LATEST VA PHYSICAL SECURITY STANDARDS, AND CAMPUS
STANDARDS.
E. SEE TYPICAL WALL FRAMING DETAILS ON SHEET A-511.
F. SEE TYPICAL HEAD OF WALL DETAIL ON SHEET A-512.
G. SEE TYPICAL CEILING DETAILS ON SHEET A-531
PARTITION RATING GRAPHICS:
4 HR FIRE BARRIER
3 HR FIRE BARRIER
2 HR FIRE & SMOKE BARRIER
2 HR FIRE BARRIER
2 HR FIRE BARRIER/SHAFT
1 HR FIRE & SMOKE BARRIER
1 HR FIRE BARRIER
1 HR FIRE BARRIER/SHAFT
SMOKE PARTITION (NON RATED)
NON RATED
PARTITION RATING GRAPHIC DESIGNATION: PRIORITY
1 HIGHEST
5 LOWEST
PARTITIONS REQUIRED TO BE SMOKE RESISTANT, FIRE
RESISTANT, OR BOTH FIRE AND SMOKE RESISTANT ARE SHOWN
GRAPHICALLY ON PLANS WITH HATCH PATTERNS.
ACOUSTICAL OR RATED
FLEXIBLE SEALANT
FLOOR LINE
ADD ONE LAYER OF 5/8" GWB,
ONE-SIDE WITH APPROVED UL
SETTING COMPOUND BETWEEN
LAYERS AND FASTENED TO
WALL AS REQUIRED, AT
EXISTING GWB WALL
ASSEMBLIES
STRUCTURAL DECK
EXISTING METAL STUDS AND
BATT INSULATION TO REMAIN
A/C GRADE, 3/4" FIRE-TREATED
PLYWOOD TO 8'-0" ABOVE FINISHED
FLOOR, ADHERED TO CONCRETE AT
EXISTING CONCRETE WALL
ASSEMBLIES
BOTTOM OF PLYWOOD
TO BE AT 12" AFF
UL DESIGN V497
1-HOUR PARTITION RATED FROM BOTH SIDES
EXISTING GWB OR
CONCRETE WALL
ASSEMBLY, WHERE OCCURS
SIDE OF
EXISTING
ROOM OR
CORRIDOR TO
REMAIN
A-512
E4
A-512
B4
ACOUSTICAL OR RATED
SEALANT BOTH SIDES
FLOOR LINE
5/8" GWB BOTH SIDES
SOUND ATTENUATION
BATTS (SAB) PER
SCHEDULE.
CEILING LINE
STRUCTURAL DECK
METAL STUDS, SIZE
PER SCHEDULE
A-512
E4
A/C GRADE, 3/4" FIRE-
TREATED PLYWOOD TO 8'-0"
ABOVE FINISHED FLOOR
A-512
B4
AT FIRE RATED
PARTITIONS
AT SMOKE RATED
PARTITIONS
BOTTOM OF PLYWOOD TO
BE AT 12" AFF
TELECOM
ROOM
440A
119 SF
'-0
10'-0"
440A
D3
A-402
B
B
A-401
D1
S L O
P E
SLOPE
S L O
P E
SLOPE
TELECOM
ROOM
440A
119 SF
D3
A-402
/2
D3
A-402
FOURTH LEVEL
48' - 0"
1/2" / 1'-0"
'-0
TELECOM
ROOM
440A
119 SF
TIE IN NEW WALL MEMBRANE
INTO NEW ROOFING MEMBRANE
NEW EXTERIOR WALL:
FIBER-CEMENT PANELS (PRE-FINISHED, WHITE, TEXTURED,
HARDIEBOARD BASIS OF DESIGN)
2" RIGID INSULATION
MOISTURE BARRIER
EXTERIOR SHEATHING
6" METAL STUDS
5/8" GYPSUM WALL-BOARD
NEW ROOF:
EPDM ROOFING
2" RIGID INSULATION
MOISTURE BARRIER
EXTERIOR SHEATHING
6" METAL STUDS
5/8" GYPSUM WALL-BOARD
PROVIDE SLEEPERS AND NEW SUBFLOOR AS REQUIRED
FOR A LEVEL FLOOR THAT IS AT THE SAME ELEVATION
AS THE FOURTH FLOOR
SECURE BOTTOM TRACK TO ROOF STRUCTURAL DECK
TELECOM
ROOM
440A
119 SF
A-402
B7
N
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
KEY PLAN
B1
AREA A
TRIPLE C - The A/E Group
4625 Lindell Blvd., 2nd Floor, 2064
St. Louis, MO 63108
MAT PERKINS
314-372-0067
/30 /20
B
IM
/5
A
-2
-7
E H
R M
I n fr a s tr u c tu re U p g ra d e s
W ic h it a /5
A
-2
-7
E
H R
M
W ic h it a
B
A R
C H
.r v t
/1
/2
:0
:3
P
M
A-402
ARCHITECTURAL ENLARGED PLANS - FOURTH
LEVEL
589A7-21-700
B1, 1A, 1B, 1C
06/30/21 M. Perkins K. McDermott
ISSUED FOR
CONSTRUCTION
EHRM INFRASTRUCTURE
UPGRADES
5500 E. KELLOGG, WICHITA, KANSAS 67218-1607
DOOR AND FRAME SCHEDULE
IDENTIFICATION DIMENSIONS PANEL FRAME DETAIL
FIRE RATING
HARDWARE
NOTESLEVEL ROOM NO. ROOM NAME DOOR NO. W H T TYPE MATERIAL FINISH GLAZING UNDERCUT TYPE MATERIAL FINISH HEAD JAMB SILL GROUP ELECTRICAL
FIRST LEVEL 150 TELECOM ROOM 150 3' - 0" 7' - 0" 1 3/4" EXT'G WD WD NONE 3/8" EXT'G HM PTD 45 MIN SEE SPEC SEE ELEC 1,2,3
FOURTH LEVEL 440A TELECOM ROOM 440A 3' - 0" 7' - 0" 1 3/4" F HM PTD NONE 3/8" 1 HM PTD 45 MIN SEE SPEC SEE ELEC 1,2,3
NOTE: FIRE RESISTANCE TEST FOR ONE HOUR RATED WALLS: UL
U465
(TYPE A) TYPICAL PARTITION
MARK STUD WIDTH PRTN WIDTH DESIGN STC
A4 4" 5 1/4" 35
NOTE: FIRE RESISTANCE TEST FOR TWO HOUR RATED WALLS: UL
V438, UL U411
(TYPE B) TYPICAL PARTITION
MARK STUD WIDTH PRTN WIDTH DESIGN STC
B 2 1/2" 3/4" 45
1 REMOVE / RELOCATE ROOF UTILITIES / FIXTURES FOR NEW TELECOM
ROOM.
2 NEW DOOR AND FRAME IN EXISTING WALL, VERIFY DEPTH. MODIFY
EXISTING FRAMING AS REQUIRED FOR INSTALLATION. PATCH /
REPAIR ADJACENT FINISHES AS REQUIRED FOR CONTINUOUS FINISH.
3 TELECOM ROOM TO BE OPEN TO DECK ABOVE.
4 REMOVE AND RELOCATE ROOF DRAIN. MODIFY PIPING IN CEILING
SPACE BELOW AS REQUIRED FOR RELOCATION. COORDINATE
ACCESS WITH COR.
5 REMOVE PORTION OF GUTTER TO DRAIN ONTO NEW ROOF.
6 PROVIDE NEW SLOPED INSULATION AND ROOFING MEMBRANE TO
RE-SLOPE ROOF TO DRAIN TOWARDS RELOCATED ROOF DRAIN. SEE
DETAIL F3/A-501
7 REMOVE EXISTING DUCT AND CAP BELOW ROOF DECK. REPAIR
EXISTING ROOF.
8 RELOCATE EXISTING ELECTRICAL DISCONNECT. REPULL
CONDUCTORS AND INSTALL ON NEW PARTITION
9 RECLOCATE EXISTING LIGHTNING PROTECTION SYSTEM TO
COORDINATE WITH NEW TR.
1/4" = 1'-0" B7
ARCHITECTURE FLOOR PLAN - 4TH LEVEL
1/4" = 1'-0" D7
ARCHITECTURE DEMO PLAN - 4TH LEVEL
1/4" = 1'-0" B5
ARCHITECTURE RCP - 4TH LEVEL
1/4" = 1'-0" D5
ARCHITECTURE ROOF PLAN - 4TH LEVEL
DOOR SCHEDULE NOTES:
1. DOOR PANEL AND FRAME TO BE SMOKE-RATED FOR TRANSITION, INCLUDING CLOSER, SEALS, THRESHOLD, AND SWEEP.
2. PAINT DOOR TRIM TO MATCH EXISTING TRIM PAINT IN SPACE.
3. COORDINATE DOOR PANEL, FRAME, AND HARDWARE WITH ELECTRICAL HARDWARE (ACCESS CONTROL, ELECTRICAL STRIKE, DOOR-CONTACT SWITCH, ETC.) SEE ELECTRICAL PLANS FOR ADDITIONAL INFORMATION.
1/4" = 1'-0" D3
NEW TELECOM ROOM SECTION
NOT TO SCALE
B3
FOURTH LEVEL NEW TELECOM ROOM LOCATION
1/32" = 1'-0" F3
FOURTH FLOOR PLAN REFERENCE
RELOCATE ROOF DRAIN
REMOVE PORTION OF GUTTER TO DRAIN ONTO NEW ROOF.
Revisions: Date:
Addendum 1 01/20/2022
1/2" 1/2"
VARIES
SEE PLAN
NEW PARTITION
WALL, BEYOND -
SEE PLAN FOR
TYPE
NEW THRESHOLD,
SET IN FULL BED OF
SEALANT - EA. SIDE
& ALL AROUND, TYP.
NEW HOLLOW METAL
FRAME
NEW SWEEP
U N
D E
R C
U T
V E
R
IF
Y
1/2" 1/2"
VARIES
SEE PLAN
WALL - SEE PLAN
FOR TYPE
SEALANT - EA. SIDE
& ALL AROUND,
TYP.
HOLLOW METAL
FRAME
/2
V
A R
IE
S
S E
E P
L A
N
/2
4" 2"
ADJACENT WALL
WHERE OCCURS
SEALANT - EA SIDE &
ALL AROUND, TYP.
HOLLOW METAL
FRAME
WALL - SEE PLAN
FOR TYPE
D1
TYPICAL FRAME
H E
IG
H
T
2" WIDTH 2"
E1
FRAME TYPE ELEVATIONS DOOR TYPE ELEVATIONS
F
FLUSH
F1
SHEET SYMBOL LEGEND
KEYNOTES
GENERAL NOTES
EXISTING CONSTRUCTION TO REMAIN
EXISTING CONSTRUCTION TO BE DEMOLISHED
NEW CONSTRUCTION, WITH PARTITION TYPE
A
A. SEE GENERAL NOTES AND PLANS FOR TYPICAL GENERAL
PROJECT REQUIREMENTS AND PROJECT LOCATION DRAWINGS.
B. SEE INTERIOR FINISH DRAWINGS FOR ADDITIONAL FINISHES
INFORMATION.
C. SEE MECHANICAL AND ELECTRICAL DRAWINGS FOR ADDITIONAL
SYSTEMS INFORMATION.
D. NEW IT CLOSETS SHALL BE SMOKE RATED AND COMPLY WITH
THE LATEST VA PHYSICAL SECURITY STANDARDS, AND CAMPUS
STANDARDS.
E. SEE TYPICAL WALL FRAMING DETAILS ON SHEET A-511.
F. SEE TYPICAL HEAD OF WALL DETAIL ON SHEET A-512.
G. SEE TYPICAL CEILING DETAILS ON SHEET A-531
PARTITION RATING GRAPHICS:
4 HR FIRE BARRIER
3 HR FIRE BARRIER
2 HR FIRE & SMOKE BARRIER
2 HR FIRE BARRIER
2 HR FIRE BARRIER/SHAFT
1 HR FIRE & SMOKE BARRIER
1 HR FIRE BARRIER
1 HR FIRE BARRIER/SHAFT
SMOKE PARTITION (NON RATED)
NON RATED
PARTITION RATING GRAPHIC DESIGNATION: PRIORITY
1 HIGHEST
5 LOWEST
PARTITIONS REQUIRED TO BE SMOKE RESISTANT, FIRE
RESISTANT, OR BOTH FIRE AND SMOKE RESISTANT ARE SHOWN
GRAPHICALLY ON PLANS WITH HATCH PATTERNS.
BUILDING 1A
BREAK
ROOM
366 SF
E L
E C
T R
IC
A
L
A
S
F
TELECOM
ROOM
002A
100 SF
CORRIDOR
0CORRA
62 SF
SERVER
ROOM
355 SF
MECHANICAL
ROOM
650 SF
BUILDING 3
8'-2 1/4"
'-2
/8
A
A4
A
B
B
BUILDING 1A
BREAK
ROOM
366 SF
E L
E C
T R
IC
A
L
A
S
F
CORRIDOR
0CORRA
62 SF
SERVER
ROOM
355 SF
MECHANICAL
ROOM
002002
BUILDING 3
742 SF
TELECOM
ROOM
002A002A
CORRIDOR
0CORRA0CORRA
MECHANICAL
ROOM
002002
SERVER
ROOM
001001
BREAK
ROOM
006006
ELECTRICAL
006A006A
BUILDING 1ABUILDING 3
CORRIDOR
0CORRA0CORRA
MECHANICAL
ROOM
002002
SERVER
ROOM
001001
BREAK
ROOM
006006
ELECTRICAL
006A006A
BUILDING 1ABUILDING 3
TELECOM
ROOM
002A002A
A-402
C7
N
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
KEY PLAN
TRIPLE C - The A/E Group
4625 Lindell Blvd., 2nd Floor, 2064
St. Louis, MO 63108
MAT PERKINS
314-372-0067
BUILDING
/30
/20
B
IM
/5
A
-2
-7
E H
R M
I n fr a s tr u c tu re U p g ra d e s
W ic h it a /5
A
-2
-7
E
H R
M
W ic h it a
B
A R
C H
.r v t
/1
/2
:4
:0
P
M
A-401
ARCHITECTURAL ENLARGED PLANS - GROUND
LEVEL
589A7-21-700
B3
06/30/21 M. Perkins K. McDermott
ISSUED FOR
CONSTRUCTION
EHRM INFRASTRUCTURE
UPGRADES
5500 E KELLOGG, WICHITA, KANSAS 67218-1607
3" = 1'-0" F1
HOLLOW METAL THRESHOLD DETAIL
3" = 1'-0" D1
HOLLOW METAL HEAD DETAIL
3" = 1'-0" E1
HOLLOW METAL JAMB DETAIL
1/4" = 1'-0" C1
WRAPPED FRAME TYPES ELEVATIONS
1 TELECOM ROOM CEILING TO BE OPEN TO DECK ABOVE.
2 ALIGN NEW WALL WITH FACE OF EXISTING FOR CONTINUOUS
FINISH.
3 REMOVE DUMB-WAITER EQUIPMENT AND CHASE-WALLS IN IT'S
ENTIRERTY.
4 REMOVE FLOORING FOR NEW TELECOM ROOM. PREP SUBFLOOR
FOR NEW FINISH.
5 TRIANGLE HATCH INDICATES AREA KNOWN TO CONTAIN ASBESTOS
CONTAINING MATERIAL, MASTIC UNDER FLOORING. CONTRACTOR
TO VERIFY EXTENT AND FULLY REMOVE, FOLLOWING THE
REQUIREMENTS OF SPECIFICATION SECTION 02 82 11 OR 02 82 13.
6 WALLS TO BE SMOKE-RATED. PATCH AND SEAL ALL PENETRATIONS
AS NECESSARY.
7 DOOR TO BE SMOKE-RATED. SEE DOOR SCHEDULE AND
SPECIFICATIONS FOR ADDITIONAL INFORMATION. COORDINATE
DOOR WITH NEW ACCESS CONTROL HARDWARE.
8 REMOVE PORTION OF EXISTING SLAB TO PREPARE FOR NEW TR.
9 EXISTING UTILITIES ABOVE TO REMAIN. COORDINATE WITH NEW
PARITIONS AND PROVIDE RATED PENETRATIONS.
10 EXISTING ELECTRICAL PANELS TO BE RELOCATED AND
REINSTALLED WITH NEW TR.
1/4" = 1'-0" C7
ARCH ENLARGED FLOOR PLAN - GROUND LEVEL
1/4" = 1'-0" F7
ARCH ENLARGED DEMO FLOOR PLAN - GROUND LEVEL
1/4" = 1'-0" C5
ARCH ENLARGED RCP - GROUND LEVEL
1/4" = 1'-0" F5
ARCH ENLARGED DEMO RCP - GROUND LEVEL
DOOR AND FRAME SCHEDULE
IDENTIFICATION DIMENSIONS PANEL FRAME DETAIL
FIRE
RATING
STC
Rating
HARDWARE
NOTESLEVEL ROOM NO. ROOM NAME DOOR NO.
WIDTH
H T TYPE MATERIAL FINISH GLAZING UNDERCUT TYPE MATERIAL FINISH HEAD JAMB SILL GROUP ELECTRICALW1
FIRST LEVEL 162 OFFICE 162 3' - 0" 7' - 0" 1 3/4" F WD WD NONE 3/8" 1 HM PTD
FIRST LEVEL 162A TELECOM ROOM 162A 3' - 0" 7' - 0" 1 3/4" F WD WD NONE 3/8" 1 HM PTD
GROUND LEVEL 002A TELECOM ROOM 002A 3' - 0" 7' - 0" 1 3/4" F WD WD NONE 3/8" 1 HM PTD
SECOND FLOOR 210 TELECOM ROOM 210 3' - 6" 7' - 0" 1 3/4" EXT'G EXT'G --- --- 3/8" EXT'G EXT'G --- SEE SPEC SEE ELEC
DOOR SCHEDULE NOTES:
1. DOOR PANEL AND FRAME TO BE SMOKE-RATED FOR TRANSITION, INCLUDING CLOSER, SEALS, THRESHOLD, AND SWEEP.
2. PAINT DOOR TRIM TO MATCH EXISTING TRIM PAINT IN SPACE.
3. COORDINATE DOOR PANEL FRAME, AND HARDWARE WITH ELECTRICAL HARDWARE (ACCESS CONTROL, ELECTRICAL STRIKE, DOOR CONTACT SWITCH, ETC.) SEE ELECTRICAL PLANS FOR ADDITIONAL INFORMATION.
4. NEW DOOR PANEL AND FRAME - RE-USE EXISTING OFFICE DOOR HARDWARE.
SEE SPEC SEE ELEC
SEE SPEC SEE ELEC
1,3
1,2,3
1,2,3
2,4
F1
F1
F1
E1
E1
E1
E1
D1
D1
D1
D1
1" = 20'-0" F2
GROUND FLOOR REFERENCEPLAN
Revisions: Date:
Addendum 1 01/20/2022
KEYNOTES
GENERAL NOTES
EXISTING CONSTRUCTION TO REMAIN
EXISTING CONSTRUCTION TO BE DEMOLISHED
NEW CONSTRUCTION, WITH PARTITION TYPE
A
A. SEE GENERAL NOTES AND PLANS FOR TYPICAL GENERAL
PROJECT REQUIREMENTS AND PROJECT LOCATION DRAWINGS.
B. SEE INTERIOR FINISH DRAWINGS FOR ADDITIONAL FINISHES
INFORMATION.
C. SEE MECHANICAL AND ELECTRICAL DRAWINGS FOR ADDITIONAL
SYSTEMS INFORMATION.
D. NEW IT CLOSETS SHALL BE SMOKE RATED AND COMPLY WITH
THE LATEST VA PHYSICAL SECURITY STANDARDS, AND CAMPUS
STANDARDS.
E. SEE TYPICAL WALL FRAMING DETAILS ON SHEET A-511.
F. SEE TYPICAL HEAD OF WALL DETAIL ON SHEET A-512.
G. SEE TYPICAL CEILING DETAILS ON SHEET A-531
PARTITION RATING GRAPHICS:
4 HR FIRE BARRIER
3 HR FIRE BARRIER
2 HR FIRE & SMOKE BARRIER
2 HR FIRE BARRIER
2 HR FIRE BARRIER/SHAFT
1 HR FIRE & SMOKE BARRIER
1 HR FIRE BARRIER
1 HR FIRE BARRIER/SHAFT
SMOKE PARTITION (NON RATED)
NON RATED
PARTITION RATING GRAPHIC DESIGNATION: PRIORITY
1 HIGHEST
5 LOWEST
PARTITIONS REQUIRED TO BE SMOKE RESISTANT, FIRE
RESISTANT, OR BOTH FIRE AND SMOKE RESISTANT ARE SHOWN
GRAPHICALLY ON PLANS WITH HATCH PATTERNS.
OFFICE
127 SF
POLICE /
SECURITY
SERVICE
123 SF
STORAGE
162A
42 SF
DUMB
WAITER
OFFICE
145 SF
OFFICE
167 SF
BUILDING 1ABUILDING 3
OFFICE
127 SF
POLICE /
SECURITY
SERVICE
123 SF
CORRIDOR
1CORR
322 SF
OFFICE
145 SF
CORRIDOR
1-CORR
367 SF
OFFICE
139 SF
TELECOM
ROOM
162A
148 SF
BUILDING 1ABUILDING 3
(EXT'G, VIF)
12'-1 1/4"
(E X
T 'G
, V
IF
'-2
/8
A
B
B
B
B
OFFICE
162162OFFICE
108108
CORRIDOR
1CORR1CORR
CORRIDOR
1-CORR1-CORR
POLICE /
SECURITY
SERVICE
107107
OFFICE
164164
STORAGE
162A
BUILDING 1ABUILDING 3
OFFICE
162162
OFFICE
164164
CORRIDOR
1CORR1CORR
CORRIDOR
1-CORR1-CORR
POLICE /
SECURITY
SERVICE
107107
OFFICE
108108
TELECOM
ROOM
162A162A
BUILDING 1ABUILDING 3
TELECOM
ROOM
162A162A A-402
C7
N
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
KEY PLAN
TRIPLE C - The A/E Group
4625 Lindell Blvd., 2nd Floor, 2064
St. Louis, MO 63108
MAT PERKINS
314-372-0067
BUILDING
/30
/20
B
IM
/5
A
-2
-7
E H
R M
I n fr a s tr u c tu re U p g ra d e s
W ic h it a /5
A
-2
-7
E
H R
M
W ic h it a
B
A R
C H
.r v t
/1
/2
:4
:3
P
M
A-402
ARCHITECTURAL ENLARGED PLANS - FIRST
LEVEL
589A7-21-700
B3
06/30/21 M. Perkins K. McDermott
ISSUED FOR
CONSTRUCTION
EHRM INFRASTRUCTURE
UPGRADES
5500 E KELLOGG, WICHITA, KANSAS 67218-1607
1 NEW IT CLOSET TO HAVE OPEN CEILING TO DECK
2 INFILL WINDOW OPENING TO MATCH ADJACENT FINISHES
3 TRIANGLE HATCH INDICATES AREA KNOWN TO CONTAIN ASBESTOS
CONTAINING MATERIAL, MASTIC AND FLOORING. CONTRACTOR TO
VERIFY EXTENT AND FULLY REMOVE, FOLLOWING THE
REQUIREMENTS OF SPECIFICATION SECTION 02 82 11 OR 02 82 13.
4 EXISTING WINDOW TO REMAIN, PROVIDE FURRING TO INFILL
OPENING ON INSIDE OF WALL FOR CONTINUOUS FINISH.
5 REMOVE CEILING TILE IN ROOM. ASBESTOS CONTAINING MASTIC IS
PRESENT AT BOTTOM OF THE HARD-LID CEILING STRUCTURE
ABOVE. CONTRACTOR TO VERIFY EXTENT AND QUANITIY OF
ASBESTOS CONTAINING MATERIAL AND DISPOSE OF PROPERLY AS
REQUIRED IN PROJECT SPECIFICATIONS.
6 INFILL WALL OPENING TO MATCH ADJACENT CONSTRUCTION FOR
CONTINUOUS FINISH.
7 EXISTING WALLS TO BECOME SMOKE-RATED. PATCH AND SEAL ALL
PENETRATIONS AS NECESSARY.
8 DOOR TO BE SMOKE-RATED. SEE DOOR SCHEDULE AND
SPECIFICATIONS FOR ADDITIONAL INFORMATION. COORDINATE
DOOR WITH NEW ACCESS CONTROL HARDWARE.
9 REMOVE FLOORING AND WALL BASE. REFER TO INTERIOR PLANS
FOR ADDITIONAL INFORMATION.
10 EXISTING RAMP. COORDINATE NEW CONSTRUCTION WITH
EXISTING SLOPE.
1/4" = 1'-0" F7
ARCH DEMO FLOOR PLAN - FIRST LEVEL
1/4" = 1'-0" C7
ARCH FLOOR PLAN - FIRST LEVEL
1/4" = 1'-0" F5
ARCH RCP DEMO PLAN - FIRST LEVEL
1/4" = 1'-0" C5
ARCH REFLECTED CEILING PLAN - FIRST LEVEL
NOT TO SCALE
F1
FIRST LEVEL NEW TELECOM ROOM LOCATION
1/16" = 1'-0" B1
FIRST FLOOR REFERENCE PLAN
Revisions: Date:
Addendum 1 01/20/2022
KEYNOTES
GENERAL NOTES
EXISTING CONSTRUCTION TO REMAIN
EXISTING CONSTRUCTION TO BE DEMOLISHED
NEW CONSTRUCTION, WITH PARTITION TYPE
A
1. SEE GENERAL NOTES AND PLANS FOR TYPICAL GENERAL
PROJECT REQUIREMENTS AND PROJECT LOCATION DRAWINGS.
2. SEE INTERIOR FINISH DRAWINGS FOR ADDITIONAL FINISHES
INFORMATION.
3. SEE MECHANICAL AND ELECTRICAL DRAWINGS FOR ADDITIONAL
SYSTEMS INFORMATION.
4. NEW IT CLOSETS SHALL BE SMOKE RATED AND COMPLY WITH
THE LATEST VA PHYSICAL SECURITY STANDARDS, AND CAMPUS
STANDARDS.
5. SEE TYPICAL WALL FRAMING DETAILS ON SHEET A-511.
6. SEE TYPICAL HEAD OF WALL DETAIL ON SHEET A-512.
7. SEE TYPICAL CEILING DETAILS ON SHEET A-531
PARTITION RATING GRAPHICS:
4 HR FIRE BARRIER
3 HR FIRE BARRIER
2 HR FIRE & SMOKE BARRIER
2 HR FIRE BARRIER
2 HR FIRE BARRIER/SHAFT
1 HR FIRE & SMOKE BARRIER
1 HR FIRE BARRIER
1 HR FIRE BARRIER/SHAFT
SMOKE PARTITION (NON RATED)
NON RATED
PARTITION RATING GRAPHIC DESIGNATION: PRIORITY
1 HIGHEST
5 LOWEST
PARTITIONS REQUIRED TO BE SMOKE RESISTANT, FIRE
RESISTANT, OR BOTH FIRE AND SMOKE RESISTANT ARE SHOWN
GRAPHICALLY ON PLANS WITH HATCH PATTERNS.
OXYGEN
34 SF
CARDIOLOGY
TEAM
ADMIN
197 SF
HAC
34 SF
TLT
44 SF
CORRIDOR
2-CORR
331 SF
STORAGE
238 SF
OXYGEN
34 SF
CARDIOLOGY
TEAM
ADMIN
197 SF
HAC
34 SF
TLT
44 SF
CORRIDOR
2-CORR
331 SF
STORAGE
238 SF
STORAGE
106 SF
OXYGEN
34 SF
CARDIOLOGY
TEAM
ADMIN
197 SF
HAC
34 SF
TLT
44 SF
CORRIDOR
2-CORR
331 SF
TELECOM
ROOM
200A
117 SF
8'-7 7/8"
'-1
1/
2"
B
B
B
B
B
A4
A
A
STORAGE
106 SF
OXYGEN
34 SF
CARDIOLOGY
TEAM
ADMIN
197 SF
HAC
34 SF
TLT
44 SF
CORRIDOR
2-CORR
331 SF
TELECOM
ROOM
200A
117 SF
TELECOM
ROOM
200A
117 SF
A-403
B7
N
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
KEY PLAN
TRIPLE C - The A/E Group
4625 Lindell Blvd., 2nd Floor, 2064
St. Louis, MO 63108
MAT PERKINS
314-372-0067
BUILDING
B
IM
/5
A
-2
-7
E H
R M
I n fr a s tr u c tu re U p g ra d e s
W ic h it a /5
A
-2
-7
E
H R
M
W ic h it a
B
A R
C H
.r v t
/1
/2
:5
:4
P
M
A-403
ARCHITECTURAL ENLARGED PLANS - SECOND
LEVEL
589A7-21-700
B19
06/30/21 M. Perkins K. McDermott
ISSUED FOR
CONSTRUCTION
EHRM INFRASTRUCTURE
UPGRADES
5500 E. KELLOGG, WICHITA, KANSAS 67218-1607
1/4" = 1'-0" E7
ARCHITECTURAL SECOND LEVEL - DEMOLITION PLAN
1/4" = 1'-0" E4
ARCHITECTURAL SECOND LEVEL - REFLECTED CEILING DEMOLITION PLAN
1/4" = 1'-0" B7
ARCHITECTURAL SECOND LEVEL - PROPOSED PLAN
1/4" = 1'-0" B4
ARCHITECTURAL SECOND LEVEL - REFLECTED CEILING PLAN
1 MODIFY WALL FRAMING AS REQUIRED FOR NEW DOOR AND FRAME.
2 NEW DOOR AND FRAME. MODIFY WALL FRAMING AS REQUIRED.
3 EXISTING DOOR TO BECOME SMOKE RATED. SEE DOOR SCHEDULE
AND SPECIFICATION FOR ADDITIONAL INFORMATION. MODIFY DOOR
AS REQUIRED FOR NEW ACCESS CONTROL HARDWARE.
4 EXISTING WALLS TO BECOME SMOKE-RATED. MODIFY AS
REQUIRED TO EXTEND TO DECK ABOVE.
5 REMOVE SUSPENDED CEILING TILES AND GRID IN IT'S ENTIRETY.
6 TELECOM ROOM TO BE OPEN UP TO DECK ABOVE.
7 EXISTING RAMP WITH APPROX. 5" ELEVATION CHANGE.
COORDINATE WITH NEW CONSTRUCTION.
NOT TO SCALE
E2
SECOND LEVEL NEW TELECOM ROOM LOCATION
1" = 10'-0"
E1
SECOND FLOOR PLAN REFERENCE
Revisions: Date:
Addendum 1 01/20/2022
| 589A7-21-700_EHRM Infrastructure Upgrades_Addendum_1.20220120 |
| SITE.AS100.ADD1.20220120 |
| Sheets |
| AS100 - SITE PLAN - NEW COMMUNICATIONS BASE BID |
| SITE.T-602.ADD1.20220120 |
| Sheets |
| T-602 - SITE PLAN - COMMUNICATIONS ONE-LINE DIAGRAM - NEW BASE BID |
| B01.A-402.ADD1.20220120 |
| Sheets |
| A-402 - ARCHITECTURAL ENLARGED PLANS - FOURTH LEVEL |
| B03.A-401.ADD1.20220120 |
| Sheets |
| A-401 - ARCHITECTURAL ENLARGED PLANS - GROUND LEVEL |
| B03.A-402.ADD1.20220120 |
| Sheets |
| A-402 - ARCHITECTURAL ENLARGED PLANS - FIRST LEVEL |
| B19.A-403.ADD1.20220120 |
| Sheets |
| A-403 - ARCHITECTURAL ENLARGED PLANS - SECOND LEVEL |
File details come from the government source that posted it. Updated .