X1 - edg-edgr.pdf
PDF 587 KB Posted
- Attached to
- Z1DA--Remodel Fort Wayne Chapel 610A4-22-203
- Solicitation number
- 36C25025B0010
About this file
This file is a technical specification document for LED edge-lit exit signs from Lithonia Lighting, specifically the EDG (surface mount) and EDGR (recessed mount) models, which appears to be part of the requirements for the Fort Wayne VA Chapel remodeling project.
The document details two types of LED edge-lit exit signs with extruded brushed aluminum finish and clear acrylic panels featuring 6" high letters with 3/4" stroke and 100 ft viewing distance rating. Both models offer dual voltage input (120/277V), optional nickel-cadmium battery backup providing 90 minutes of emergency operation, and self-diagnostic testing capabilities. The signs are UL damp location listed for 32°-122°F, meet UL924, NFPA 101, NEC and OSHA standards, and include a 5-year warranty. The BAA (Buy American Act) option ensures compliance with government procurement requirements. Key options include single or double face displays, red or green lettering, and various mounting configurations. The typical LED life is rated at 10 years, with input power ranging from 2.2 to 4.5 watts depending on configuration.
View the file
Other files
Show all 33
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
EMERGENCY EDG-EDGR
Catalog Number
Notes
Type
ORDERING INFORMATION For shortest lead times, configure products using bolded options. Example: EDG 1 R EL
Family Housing color Number of faces Letter color Operations Options
EDG Surface mount LED edge-lit exit
EDGR Recessed LED edge-lit exit
(blank) Brushed aluminum
W White
1 Single face 2 Double face
R Red on clear (single face only)1
G Green on clear (single face only)1
RMR Red on mirror2
GMR Green on mirror2
RW Red on white3
GW Green on white3
(blank) AC only EL Nickel-cadmium battery
X2 Lamp wired on two separate AC circuits (specify 120V or 277V)4
SD Self-diagnostics5
(blank) None WM Recessed wall mount6
BAA Buy America(n) Act Compliant
Accessories: Order as separate item.
ELA US12 12” stem kit with brushed aluminum canopy7
ELA W US12 12” stem kit with white canopy7
ELA WG1 Wireguard (13 3/4”H x 15 1/4”W x 6” D, back mount only)
FEATURES & SPECIFICATIONS
INTENDED USE — Suitable for applications requiring attractive edge-lit exit signage, universal installa-tion and low energy consumption.
CONSTRUCTION — Extruded brushed aluminum finish.
Clear acrylic panels- letters measure 6” high with 3/4” stroke, with 100 ft viewing distance rating, based upon UL 924 standard.
For single-face clear panels, EXIT is seen as a reversed image from the back.
OPTICS — LEDs mounted on printed circuit board. The typical life of the exit LED lamp is 10 years.
The LED operating frequency is 120Hz.
ELECTRICAL — Dual voltage input capacity (120/277V).
Battery: (EL Option) – Sealed, maintenance free nickel-cadmium battery delivers 90 minutes capacity to emergency lamps. Test switch provides manual activation of 30-second diagnostic testing for on-demand visual inspection.
Self-diagnostic testing (EL Option Only) for 30 seconds every 30 days and 90 minutes annually. Diagnostic evaluation of LED light source, AC to DC transfer, charging and battery condition.
INSTALLATION — EDG – Universal mounting canopy for top or end mount. Back mount standard for single face only. Canopy provided.
EDGR – Recessed mounting. Bar hanger and brackets provided for both new or restricted ceiling access installation applications. Available for use in drop ceiling applications. Back wall mount (WM) option.
Universal directional indicators. Field selected and attached.
LISTINGS — UL damp location listed 32°-122°F (0°-50°C) standard. Meets UL924, NFPA 101 (current Life Safety Code), NEC and OSHA illumination standards. Meets all applicable FCC Title 47, Part 15, Subpart B requirements.
BUY AMERICAN ACT — Product with the BAA option is assembled in the USA and meets the Buy America(n) government procurement requirements under FAR, DFARS and DOT regulations.
Please refer to www.acuitybrands.com/buy-american for additional information.
WARRANTY — 5-year limited warranty. This is the only warranty provided and no other statements in this specification sheet create any warranty of any kind. All other express and implied warranties are disclaimed. Complete warranty terms located at: www.acuitybrands.com/support/warranty/ terms-and-conditions
NOTE: Actual performance may differ as a result of end-user environment and application.
All values are design or typical values, measured under laboratory conditions at 25°C.
Specifications subject to change without notice.
† Exit Signs Certified in the CA Title 20 Appliance Efficiency Database.
LED Edge-Lit Exits
EDG
EDGR
LED Lamps
Notes
1 For single-face clear panels, EXIT is seen as a reversed image from the back.
2 Available with single and double face.
3 White panel standard for double and single face.
4 Not available with EL and SD options. Both circuits can be energized at the same time.
5 Available with EL option only.
6 Available on EDGR single face only
7 See spec sheet ELA-StemKits. Only available for EDG.
All dimensions are inches (centimeters) unless otherwise noted.
EDG (surface mount)
EDGR (recessed mount)
Specifications EDG (End Mount) EDG (Top Mount) Length: 13-5/8 (34.6) Length: 13 (33.0) Depth: 5-1/2(14.0) Depth: 4-5/16 (11.0) Height: 11-1/8 (28.3) Height: 11-3/4 (29.8) Shipping Weight : 4 lbs (1.8 kgs) Shipping Weight : 4 lbs (1.8 kgs)
EDG (Back Mount) EDGR Length: 13 (33.0) Length: 13 (33.0) Depth: 3 (7.6) Depth: 1-3/4 (4.4) Height: 11-1/8 (28.3) Height: 8 (20.3) Shipping Weight : 4 lbs (1.8 kgs) Shipping Weight : 6.8 lbs (3.1 kgs) Shipping Weight (WM option) :
8.1 lbs (3.7 kgs) https://www.acuitybrands.com/resources/buy-american http://www.acuitybrands.com/support/warranty/terms-and-conditions http://www.acuitybrands.com/support/warranty/terms-and-conditions https://img.acuitybrands.com/public-assets/catalog/111462/ela-stemkits.pdf?abl_version=01%2f06%2f2021+17:51:46&DOC_Type=SPEC_SHEET issac Rectangle issac Rectangle issac Rectangle issac Rectangle issac Rectangle
EDG-EDGR
EMERGENCY: One Lithonia Way Conyers, GA 30012 Phone: 800-705-SERV (7378) techsupport-emergency@acuitybrands.com www.lithonia.com © 2003-2022 Acuity Brands Lighting, Inc. All rights reserved. Rev. 11/08/22
SPECIFICATIONS
KEY FEATURES
EDG-EDGR LED, Surface and Recessed Mount Edge-Lit Exits
Notes
1 Based on continuous operation. The typical life of the exit LED lamp is 10 years.
2 At 77°F (25°C).
3 All life safety equipment, including emergency lighting for path of egress must be maintained, serviced, and tested in accordance with all National Fire Protection Association (NFPA) and local codes. Failure to perform the required maintenance, service, or testing could jeopardize the safety of occupants and will void all warranties.
4 Temperature range where unit will provide capacity for 90 minutes. Higher and lower temperatures affect life and capacity.
Universal chevron indicators for field selection/installation.
Test Switch Pilot Light
(Emergency Only)
Back Mount
End Mount
Top Mount 4-3/8 (11.0)
11-3/4 (29.8)
11-1/8 (28.3)
13-5/8 (34.6)
12-3/4 (32.4)
5-1/2 (14.0)
12-1/8 (30.8)
(7.6)
1/2 (1.3)
11-1/8 (28.3)
4-3/8 (11.1)
(33.0)
12-3/4 (32.4)
3/8 (1.0)
Canopy dimensions is 5-1/2" x 4-3/8"
(33.0)
1-3/4 (4.4)
(20.3)
EDG
EDGR
BATTERY (EL option)
Sealed Nickel-Cadmium
Shelf life2
Typical life2 Maintenance3 Temperature range4
3 years 6-8 years none 32-122°F (0-50°C)
14-1/2 (36.8)
3-1/4 (8.3)
2-13/16 (7.1)
5-1/2 (14.0)
4-1/8 (10.5)
15-3/4 (40.0) 8
(20.3)
(33.0)
EDGR WM option
MOUNTING
Note: For drop ceiling applications refer to the standard installation section of the instruction sheet.
Not applicable for “bracket mount” installation.
ELECTRICAL
Primary Circuit
Type Typical LED life1
Supply voltage
EDG EDGR
Input Watts
Max amps.
Input Watts
Max amps.
Red LED AC only
10 years 120 2.5 0.020 3.8 0.030
277 2.8 0.010 4.5 0.014
Green LED AC only
10 years 120 2.2 0.020 3.8 0.030
277 2.2 0.010 4.5 0.020
Red LED emergency
10 years 120 3.0 0.030 3.8 0.031
277 3.1 0.010 4.5 0.015
Green LED emergency
10 years 120 2.6 0.020 3.8 0.031
277 2.8 0.010 4.5 0.020 http://www.lithonia.com