610A4-22-203 - BID Drawings.pdf
PDF 22 MB Posted
- Attached to
- Z1DA--Remodel Fort Wayne Chapel 610A4-22-203
- Solicitation number
- 36C25025B0010
About this file
This file contains the bid drawings for a chapel remodeling project at the Fort Wayne VA Medical Center (File #610A4-22-203). Based on the associated contract opportunity, these drawings detail the demolition and construction requirements for remodeling the chapel located at 2121 Lake Ave., Fort Wayne, IN 46805. The project requires adherence to infection control requirements and accounts for potential hazardous materials including asbestos and lead-based paint that may be encountered during demolition. While specific drawing details are not provided in this excerpt, they would show the technical specifications and architectural plans that contractors must follow to complete the 183-day renovation project for the Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 10.
View the file
Other files
Show all 33
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
VA NORTHERN INDIANA HEALTH CARE SYSTEM
#610A4-22-203
DEPARTMENT OF VETERANS AFFAIRS
2121 LAKE AVENUE FORT WAYNE, IN 46805
REMODEL FORT WAYNE CHAPEL
G E N E R A L N O T E S
A. THE CONTRACT DRAWINGS AND SPECIFICATIONS (INDICATED BY THE SAME PROJECT NUMBER) ARE COMPLIMENTARY. THE CONTRACTOR SHALL NOTIFY THE CONTRACTING OFFICER'S REPRESENTATIVE (C.O.R.) OF ANY DISCREPANCIES FOUND DURING
BIDDING AND THROUGH CONSTRUCTION.
B. DO NOT SCALE DRAWINGS; DIMENSIONS SHALL GOVERN.
C. THE GENERAL CONTRACTOR SHALL VERIFY ALL EXISTING DIMENSIONS AND FIELD CONDITIONS PRIOR TO DEMOLITION AND CONSTRUCTION. IF PROVIDED, THE GENERAL CONTRACTOR SHALL EXAMINE EXISTING BUILDING DOCUMENTS. THE CONTRACTOR SHALL BRING ANY DISCREPANCIES TO THE IMMEDIATE ATTENTION OF THE CONTRACTING OFFICER
REPRESENTATIVE.
D. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR THE PROTECTION OF EXISTING ITEMS TO REMAIN DURING DEMOLITION AND
CONSTRUCTION.
E. IF CONSTRUCTION NOISE IS ANTICIPATED, SUBMIT A WRITTEN REQUEST TO THE C.O.R. FOR THE SCHEDULED TIME OF CONSTRUCTION ACTIVITIES. THE CONTRACTING OFFICER REPRESENTATIVE RESERVES THE RIGHT TO DISCONTINUE NOISY CONSTRUCTION AT ANY TIME. NO RADIOS SHALL BE PERMITTED AT ANY TIME IN WORK AREAS ADJACENT TO OCCUPIED SPACES.
F. ALL WORK SHALL BE DONE IN ACCORDANCE WITH APPLICABLE CODES AND FEDERAL AUTHORITIES, RULES AND REGULATIONS.
G. THESE DOCUMENTS SHOW DESIGN INTENT WITH MINIMUM CONSTRUCTION REQUIREMENTS AND MINIMUM QUALITY OF WORK EXPECTED. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR ALL MEANS, METHODS AND TECHNIQUES FOR CONSTRUCTION
AND EXPECTED QUALITY.
H. ALL MATERIALS UTILIZED ON THIS PROJECT SHALL BE NEW UNLESS OTHERWISE NOTED TO BE SALVAGED AND REFURBISHED.
MATERIAL QUALITY SHALL MEET OR EXCEED APPLICABLE INDUSTRY STANDARDS.
I. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR COORDINATING ALL EQUIPMENT INSTALLATION AND VARYING ALL REQUIRED ROUGH OPENINGS AND ROUGH-IN DIMENSIONS WITH THE EQUIPMENT MANUFACTURER AND C.O.R. PRIOR TO CONSTRUCTION.
J. FIELD VERIFY SIZES AND DIMENSIONS OF ALL EXISTING UTILITIES APPARATUSES IMPACTING NEW CONSTRUCTION. DETERMINE EXACT SIZE AND LOCATION OF PENETRATION WITHIN NEW CONSTRUCTION, TIGHTLY SEAL AND CAULK.
K. GENERAL CONTRACTOR SHALL HOST ONLINE CONSTRUCTION MANAGEMENT SOFTWARE FOR THE DURATION OF THE PROJECT.
CAMPUS LOCATION
Gravel Lot
LOT B
LOT A
LOT C LOT E
LOT F
LO
T
G
LOT H
R an da lia
D r
Lake Ave
CONTRACTOR
LAYDOWN AREA
PROJECT LOCATION
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
VA FORM 08 - 6231
A
FULLY SPRINKLERED
U.S. Department of Veterans Affairs
B
C
D
E
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
EXP: 12/31/2023
A u to d e s k D o c s /F t W a y n e V
A
R e m o d e l C h a p e l/ F
F E
F t W a y n e
R e m o d e l C h a p e l_
B rv t
/3
/2
:5
:4
P
M
GI001
COVER SHEET
20230901 PQ TD
REMODEL FORT WAYNE CHAPEL 610A4-22-203
FORT WAYNE, IN
BID DOCUMENTS
VA NORTHERN
INDIANA
HEALTHCARE
SYSTEM
Approved: Veteran's Affairs Medical Center
GENERAL
GI001 COVER SHEET
GI002 ABBREVIATIONS AND SYMBOLS
GI003 OVERALL CODE AND LIFE SAFETY PLAN
ARCHITECTURE
AD101 DEMOLITION FLOOR PLAN AND REFLECTED CEILING PLAN
AD401 DEMOLITION ELEVATIONS
AE101 FLOOR PLAN AND REFLECTED CEILING PLAN
AE401 ELEVATIONS, SECTIONS, AND DETAILS
AE601 DOOR SCHEDULE AND CASEWORK DETAILS
AI101 FINISH PLAN AND SCHEDULE
ELECTRICAL
E001 LEGEND
EL101 ELECTRICAL DEMO AND NEW WORK PLAN
D R A W I N G I N D E X
N
NTS
VACINITY MAP
N
NTS
CAMPUS MAP
NOTE: RENDERINGS ARE FOR GENERAL UNDERSTANDING OF PROJECT SCOPE. THIS IS NOT INTENDED TO BE USED FOR CONSTRUCTION.
No. Revisions: Date:
BID DOCUMENTS 09/01/2023
A B B R E V I A T I O N S
A.B. ANCHOR BOLT
A.C.M. ASBESTOS CONTAINING MATERIALS
A.C.P. ASPHALT CONCRETE PAVING
A/C AIR CONDITIONING
ACOUS. ACOUSTIC
A.C.T. ACOUSTICAL CEILING TILE
A.D. AREA DRAIN
ADJ. ADJUSTABLE
AFF ABOVE FINISH FLOOR
AGG. AGGREGATE
AL. ALUMINUM
ALT. ALTERNATE
APPROX. APPROXIMATE
ARCH. ARCHITECT
ASPH. ASPHALT
BD. BOARD
BITUM. BITUMINOUS
BLDG. BUILDING
BLK. BLOCK
BLKG. BLOCKING
BM. BENCH MARK OR BEAM
BOT. BOTTOM
BRG. BEARING
BRK. BRICK
BRZ. BRONZE
BTWN. BETWEEN
B.U.R BUILT-UP ROOFING
CAB. CABINET
CARP. CARPET
C.B. CATCH BASIN
C.B.B. CEMENTITIOUS BACKER BOARD
CEM. CEMENT
CER. CERAMIC
CER.T. CERAMIC TILE
C.F.C.I. CONTRACTOR FURNISH/CONTRACTOR INSTALL
C.F.O.I. CONTRACTOR FURNISH/OWNER INSTALL
C.HK. COAT HOOK
C.I. CAST IRON
CIR. CIRCLE
C.J. CONSTRUCTION JOINT
CLG. CEILING
CLG.J. CEILING JOINT
CLKG. CAULKING
CLO. CLOSET
CLR. CLEAR
CLS. CLOSURE
CMU CONCRETE MASONRY UNIT
CNTR. COUNTER
C.O. CLEAN OUT
COL. COLUMN
COMB. COMBINATION
COMP. COMPOSITION
CONC. CONCRETE
CONN. CONNECTION
CONST. CONSTRUCTION
CONT. CONTINUOUS
CONV.O. CONVECTION OVEN
C.O.R. CONTRACTING OFFICER'S REPRESENTATIVE
CTR. CENTER
C.W. COLD WATER
CW. CURTAINWALL
DET. DETAIL
DF. DOUGLAS FIR
D.F. DRINKING FOUNTAIN
DIA. DIAMETER
DIAG. DIAGONAL
DIM. DIMENSION
DISP. DISPOSAL
DIV. DIVISION
DN. DOWN
D.O. DOOR OPENING
DR. DOOR
D.S. DOWN SPOUT
D.T. DRAIN TILE
D.W. DISHWASHER
DWG(S). DRAWING(S)
DWR. DRAWER
(E) EXISTING
EA. EACH
E.C. ELECTRICAL CONTRACTOR
E.E. EACH END
E.F. EXHAUST FAN
E.J. EXPANSION JOINT
ELEC. ELECTRICAL
ELEV. ELEVATION
E.N. EDGE NAIL
ENCL. ENCLOSURE
EQUIV. EQUIVALENT
E.S. EACH SIDE
E.W. EACH WAY
E.W.C. ELECTRICAL WATER CLOSET
EXP. EXPANSION
EXP.B. EXPANSION BOLT
EXPO. EXPOSURE
EXT. EXTERIOR
F. FACE
F.A. FIRE ALARM
F.B. FACE BRICK
F.BD. FIRE BOARD
F.BELL FIRE BELL
F.B.O. FURNISHED BY OTHERS
F.D. FLOOR DRAIN
FDN. FOUNDATION
F.E. FIRE EXTINGUISHER
F.E.C. FIRE EXTINGUISHER CABINET
F.F. FINISH FLOOR
F.G. FINISH GRADE
FGL. FIBERGLASS
F.H. FIRE HYDRANT
FH.M.S. FLAT HEAD MACHINE SCREW
FIN. FINISH
FIXT. FIXTURE
F.J. FLOOR JOIST
F.L. FLOOR LINE
FLASH FLASHING
FLOUR FLUORESCENT
FLR. FLOOR
F.N. FACE NAIL
F.O.B. FACE OF BUILDING
F.O.C. FACE OF CONCRETE
F.O.F. FACE OF FINISH
F.O.M. FACE OF MASONRY
F.O.S. FACE OF STUD
F.R.T.W. FIRE RETARDANT TREATED WOOD
F.S.C. FIRE SUPPRESSION CONTRACTOR
F.S.E.C. FOOD SERVICE EQUIPMENT CONTRACTOR
FTG. FOOTING
FUT. FUTURE
F.V.C. FIRE VAULT CABINET
GA. GAUGE
GALV. GALVANIZED
G.C. GENERAL CONTRACTOR
G.B. GRAB BAR
G.D. GARBAGE DISPOSAL
G.E. GRATE ELEVATION
G.I. GALVANIZED IRON
GL. GLASS
GLB. GLUE LAMINATED BEAM
GND. GROUND
GR. GRADE
G.S.M. GALVANIZED SHEET METAL
GYP.BD. GYPSUM BOARD
H.B. HOSE BIB
HC. HANDICAPPED
HDR. HEADER
HDWD. HARDWOOD
HDWE. HARDWARE
HGT. HEIGHT
H.M. HOLLOW METAL
HORIZ. HORIZONTAL
H.P. HIGH POINT
HR. HOUR
H.S.S. HOLLOW STRUCTURAL STEEL
HTG. HEATING
H.V.A.C. HEATING, VENTILATION & AIR CONDITIONING
H.W. HOT WATER
I.D. INSIDE DIAMETER
INSUL. INSULATION
INT. INTERIOR
INV. INVERT
JAN. JANITOR
J.H. JOIST HANGER
JST. JOIST HANGER
JT. JOINT
KIT. KINTCHEN
LAB LABORATORY
LAM. LAMINATE
LAV. LAVATORY
L.B. LAG BOLT
L.H. LEFT HAND
L.L. LIVE LOAD
L.P. LOW POINT
LT. LIGHT
MAT. MATERIAL
MAX. MAXIMUM
M.B. MACHINE BOLT
M.C. MEDICINE CABINET
MECH. MECHANICAL
MED. MEDIUM
MEMB. MEMBRANE
M.E.P. MECHANICAL, ELECTRICAL, PLUMBING
MFG. MANUFACTURER
MH. MANHOLE
MIN. MINIMUM
MIR. MIRROR
MISC. MISCELLANEOUS
M.O. MASONRY OPENING
MOD. MODULAR
MP.H. MOP HOLDER
MR. FRAMED MIRROR
M.R. MOISTURE RESISTANT
M.T. METAL THRESHOLD
MTD. MOUNTED
MTL. METAL
(N) NEW
N. NORTH
NAT. NATURAL
N.I.C. NOT IN CONTRACT
(NOT PART OF OSA APPROVAL)
NO. NUMBER
NOM. NOMINAL
NON/COM NON-COMBUSTIBLE
N.T.S. NOT TO SCALE
O/ OVER
O.A. OVERALL
OBS. OBSCURE
O.C. ON CENTER
O.D. OUTSIDE DIAMETER
O.F. OVERFLOW
OFF. OFFICE
O.F.S. OUTSIDE FACE OF STUD
O.H.W.S. OVAL HEAD WOOD SCREW
OPP. OPPOSITE
P. PAINT
P.C. PLUMBING CONTRACTOR
P.C.F. POUNDS PER CUBIC FOOT
P.E.N. PANEL EDGE NAILING
PERF. PERFORATED
PL. PLATE
P.LAM PLASTIC LAMINATE
PLAS. PLASTER
P.L.F. POUNDS PER LINEAR FOOT
PLYWD. PLYWOOD
P.M.F. PRESSED METAL FRAME
PR. PAIR
PROP. PROPERTY
P.S.F. POUNDS PER SQUARE FOOT
P.S.I. POUNDS PER SQUARE INCH
P.STA. PULL STATION
PTD. PAINTED
P.T.D. PAPER TOWEL DISPENSER
PT. POINT
P.T.D.F. PRESSURE TREATED DOUGLAS
FIR
PTN. PARTITION
P.T.R. PAPER TOWEL RECEPTACLE
P.V.C. POLYVINYL-CHLORIDE
Q.T. QUARRY TILE
RAD. RADIUS
R.B. RUBBER BASE
R.C.P. REFLECTED CEILING PLAN
R.D. ROOF DRAIN
RDWD. REDWOOD
REF. REFERENCE
REFR. REFRIGERATOR
REINF. REINFORCING
REQD. REQUIRED
RESIL. RESILIENT
R.H. ROOF HATCH
R.HK. ROBE HOOK
R.H.M.S. ROUND HEAD METAL SCREW
R.H.W.S. ROUND HEAD WOOD SCREW
RM. ROOM
R.O. ROUGH OPENING
R.W.L. RAIN WATER LEADER
S. SOUTH
S.A.B. SOUND ATTENUATION BATT
S.A.D. SEE ARCHITECTURAL DRAWINGS
S.A.F.F. SELF ADHERED FLEXIBLE FLASHING
S.A.S.M. SELF ADHERED FLEXIBLE MEMBRANE
S.BLKG. SOLID BLOCKING
SCWD. SOLID CORE WOOD DOOR
S.C.D. SEE CIVIL DRAWINGS
S.D. STORM DRAIN
S.DISP. SOAP DISPENSER
SEAL. SEALANT
SECT. SECTION
S.E.D. SEE ELECTRICAL DRAWINGS
SHR. SHOWER
SHT. SHEET
SHTG. SHEATHING
SIM. SIMILAR
SL. SLIDING
S.L.D. SEE LANDSCAPE DRAWINGS
S.M.D. SEE MECHANICAL DRAWINGS
S.N.D. SANITARY NAPKIN DISPOSAL
S.N.V. SANITARY NAPKIN DISPENSER
S.P. SOUNDPROOF
SPEC. SPECIFICATION
SQ. SQUARE
SQ.FT. SQUARE FOOT (FEET)
S.S. SANITARY SEWER
S.S.D. SEE STRUCTURAL DRAWINGS
STA. STATION
STD. STANDARD
STL. STEEL
S.STL. STAINLESS STEEL
STO. STORAGE
STRUC. STRUCTRUAL
SUSP. SUSPENDED
T.B. TACKBOARD
T&B. TOP AND BOTTOM
TEL. TELEPHONE
TEMP. TEMPERED
TER. TERRAZZO
T&G. TOUNGE AND GROOVE
THK. THICK
T.J. TOOL JOINT
T.N. TOE NAIL
T.O.C. TOP OF CURB
T.O.P TOP OF PAVEMENT
T.O.PL. TOP OF PLATE
T.O.S. TOP OF SEAT
T.O.W. TOP OF WALL
T.P.D. TOILET PAPER DISPENSER
T.S. TUBE STEEL
T.V. TELEVISION
TYP. TYPICAL
UNF. UNFINISHED
U.N.O. UNLESS NOTED OTHERWISE
UR. URINAL
U/S. UNDERSIDE
V.C.T. VINYL COMPOSITION TILE
VERT. VERTICAL
VEST. VESTIBULE
V.G. VERTICAL GRAIN
V.I.F. VERIFY IN FIELD
V.T. VINYL TILE
V.T.R. VENT TO ROOF
V.W.C. VINYL WALL COVERING
(VC) V.A. FURNISHED / CONTRACTOR INSTALLED
(VV) V.A. FURNISHED AND INSTALLED
W. WEST
W/ WITH
W/IN WITHIN
W.C. WATER CLOSET
WD. WOOD
WDW. WINDOW
W.F. WATER COOLER
W.H. WATER HEATER
W/O WITHOUT
W.P. WATER PROOF
W.R. WATER RESISTANT
WT. WEIGHT
W.W.F. WELDED WIRE FABRIC
YD. YARD
P1
A101
SIM
A101
SIM
A101
SIM
A101
SIM
LEVEL NAME W/ ELEVATION
NEW GRID HEAD
CALL OUT HEAD W/ SHEET NUMBER
ROOM NAME W/ ROOM NUMBER, AREA
& OCCUPANCY
BUILDING SECTION NUMBER W/ SHEET
NUMBER
WALL SECTION NUMBER W/
SHEET NUMBER
DOOR NUMBER
WALL TAG
KEYNOTE
REVISION TAG
FINISH TAG
DETAIL SECTION NUMBER W/
SHEET NUMBER
NORTH ARROW
LEVEL
ELEVATION
150 SF
S Y M B O L S
N
WINDOW TAGA
0 EXISTING GRID HEAD
10'-0" CEILING HEIGHT TAG
ROOM NAME
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
VA FORM 08 - 6231
A
FULLY SPRINKLERED
U.S. Department of Veterans Affairs
B
C
D
E
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
EXP: 12/31/2023
A u to d e s k D o c s /F t W a y n e V
A
R e m o d e l C h a p e l/ F
F E
F t W a y n e
R e m o d e l C h a p e l_
B rv t
/3
/2
:5
:4
P
M
GI002
ABBREVIATIONS AND SYMBOLS
20230901 Checker Author
REMODEL FORT WAYNE CHAPEL 610A4-22-203
FORT WAYNE, IN
BID DOCUMENTSVA NORTHERN
INDIANA
HEALTHCARE
SYSTEM
Approved: Veteran's Affairs Medical Center
DN
GF
D D
D D
D
60" MH
MULTIPURPOSE
1-C-115
STAFF
LOUNGE
1-C-116
TOILET
1-C-146
TOILET
1-C-147
TEAM ROOM
(FUTURE
ELEV.)
1-C-EL3
CLEAN
UTILITY
1-C-145
CONSULT 26
1-C-144
EXAM 25
1-C-143
EXAM 24
1-C-142
OIT
1-C-139
MED ROOM 2
1-C-141
ELECTRICAL
1-C-140
HYBRID 23
1-C-138
EXAM 22
1-C-137
EXAM 21
1-C-136
HYBRID 20
1-C-135
TEAM ROOM
(FUTURE
ELEV.)
1-C-EL1-2
TOILET
1-C-132
CONSULT
1-C-129
EXAM 12
1-C-128
HYBRID 13
1-C-127
EXAM 14
1-C-126
EXAM 15
1-C-125
MED ROOM 1
1-C-124
CONSULT 16
1-C-122
CONSULT 19
1-C-119
CONSULT 18
1-C-120
CONSULT 17
1-C-121
EXAM 10
1-C-114
EXAM 9
1-C-113
EXAM 8
1-C-112
HYBRID 7
1-C-111P. TOILET
1-C-110
EXAM 6
1-C-109
EXAM 5
1-C-108
EXAM 4
1-C-107
EXAM 3
1-C-106
EXAM 2
1-C-105
NEG.
PRESSURE
HYBRID
1-C-104
STAIR 9
FUTURE
1-C-ST2
OPEN
OFFICE
1-C-148
CORRIDOR
1E-4
PATIENT
CORR.
1-C-C2
INTAKE #2
1-C-130
CORRIDOR
1-C-C3
OPEN
OFFICE
1-C-117
DW
1-C-123
DW
1-C-133
STORAGE
1-C-134
EQUIPMENT
STORAGE
1-C-118
PATIENT
CORR.
1-C-C1
INTAKE #1
1-C-103
STAIR 10
1-C-ST1
VESTIBULE
1-C-100
CONCIERGE
1-C-101A
RECEPTION
1-C-102
COFFEE
1-C-101D
KIOSKS
1-C-101C
CORRIDOR
1-C-C5
WAITING
1-C-101
WAITING
EGRESS
CORRIDOR
1-C-C4
NURSE
MANAGER
FUTURE HAC
148A
TOILET
MECHANICAL
PATIENT
EDUCATION
TOILET
STAIR 3
SOILED
UTILITY
OFFICE
RECEP
EXAM 5-2
154A
OFFICE
RECEP
CHECK-IN
EXAM 4-2
EXAM 4-1
158A
OFFICE
RN-3
EXAM 3-1
EXAM 3-2
162A
OFFICE
STAIR 4
OFFICE
CLEAN
UTILITY 2
OFFICE
PROCEDURE
PR. TOILET
167A
RN-2
EXAM 2-1
169A
OFFICE
RN-1
EXAM 1-2
172EXAM 1-1
175A
CORRIDOR
1E-3
DATA
TOILET
SMALL
CONFERENCE
STAFF
LOUNGE
MEANS
TESTING
138BELIGIBILITY
138A
PATIENT
REGISTRATION
MULTIPURPOSE
100A
STORAGE
OFFICE
LOCKERS
A169
SECURITY
MENS
TOILET
WOMENS
TOILET
DATA
176A
CONSULT
121G
OFFICE
121F
EXAM
121E
CORRIDOR
EXAM
121B
EXAM
120A
EXAM
LAB
OFFICE
TOILET
PHARMACY
ENGINEERING
109D
OFFICE
109C
MECH
A109B
STORAGE
A109A OFFICE
EXAM
EXAM
107A
EXAM
OFFICE
EXAM
EXAM
123A
EXAM
123B
EXAM
123C
WAITING
RECEP
EXAM
TOILET
OFFICE
EXAM
132BREAK
EXAM
EXAM
OFFICE
OFFICE
OFFICE
CORRIDOR
128A
OFFICE
A138
TRIAGE
A136
OFFICE
A135
EXAM
A133
EXAM
A131
EXAM
A115
EXAM
A114
EXAM
A112
EXAM
A110
EXAM
A108
OFFICE
A106
CLINIC
A102
ROOM
A102A
WAITING
A116
TOILET
A113
STORAGE
A130
H.A.C.
A129
EXAM
A111
EXAM
A128
EXAM
A109
EXAM
A126
CLEAN
UTILITY
A124
SOILED
UTILITY
A107
SOILED
UTILITY
A132 CLEAN
UTILITY
A134
ROOM
A127
OBSERVATION
A127A
BATH
A127B
MED
A137
NURSE
STATION
A145
TOILET
A146
OFFICE
A144
TOILET
A125
TOILET
A123
EMERGENCY
A139
NURSE
STATION
A122
EXAM
A105
MED
A120
EXAM
A103
EXAM
A118
OFFICE
A121
EXAM
A119
EXAM
A117
RECEPTION
A140
EXAM
A143
EXAM
A152
EXAM
A142
EXAM
A150
EXAM
A141
A170
MECH
A155
A154
OFFICE
A156
OFFICE
A156A
OFFICE
A156B
ROOM
A156C
OFFICE
A156D
EXAM
A153
STORAGE
A151
A149
OFFICE
A156F
ROOM
A156E
A157
CASHIER
A158
A159
OFFICE
STAIR 1
OFFICE
CLOSET
180A
H.A.C.
OFFICE
CHAPEL
STORAGE
192C
KITCHEN
192B
STORAGE
192A
AUDITORIUM
STORAGE
BELOW
STAIRS
OFFICE
OFFICE
CLOSET
184A
TOILET
A165
TOILET
A166
ON CALL
169E
VENDING
SPECIALTY
1-C-154
HYBRID 5-1
GARAGE
EXAM
VESTIBULE
OFFICE
OFFICE
STORAGE
WELCOME
LOUNGE
A167
STAIR 2
REGISTRATION
A164
WELCOME
DESK
A104
ONCOLOGY
WAITING
A101
REGISTER
MED
STORAGE
135A
STORAGE
134A
MED
133A
TOILET
126A
FIRE
PROTECTION
123D
SOILED
UTILITY
H.A.C.
124LACTATION
121D
EXAM
121A
MECH
EXAM
121H
110B
WAITING
BATH
VESTIBULE
EXAM
A148
MECH
A156G
VESTIBULE
STAIR 5
P A
T H
O F
T R
A V
E L
0'
PATH OF TRAVEL 230' < 250'
PROJECT AREA
2 HOUR FIRE BARRIER
1 HOUR FIRE BARRIER
2 HOUR SMOKE BARRIER
NON RATED SMOKE BARRIER
HE
EX EXIT
EP EXIT PASSAGEWAY
SUITE DESIGNATIONS
AREA OPEN TO CORRIDOR -
WITH SMOKE DETECTION
AREA OPEN TO
CORRIDOR - NO SMOKE
DETECTION REQUIRED
3 HOUR FIRE BARRIER
HAZARDOUS ROOM
UNDER RENOVATION
EXIT STAIR OR
PASSAGEWAY
EXIT SIGN
FIRE EXTINGUISHER
1 HOUR SMOKE BARRIER
HORIZONTAL EXIT PASSAGEWAY
HEALTHCARE OCCUPANCY CORRIDOR
SPRINKLER AND FIRE ALARM ZONE BOUNDARY
L E G E N D
C O D E N O T E S
2021 NFPA 101 LIFE SAFETY CODE REVIEW
BUILDING 1, 1ST FLOOR
AREA OF WORK = 1,350 GSF
CHAPTER 6 - CLASSIFICATION OF OCCUPANCY AND HAZARD OF CONTENT
6.1.2 EXISTING ASSEMBLY OCCUPANCY (CHAPTER 13) - NO CHANGE
6.2.2 HAZARD CLASSIFICATION: ORDINARY - NO CHANGE
CHAPTER 7- MEANS OF EGRESS: NO CHANGE
T7.3.1.2 OCCUPANT LOAD OF SPACE: 100 - NO CHANGE
CHAPTER 8 - FEATURES OF FIRE PROTECTION: FULLY SPRINKLERED - NO CHANGE
CHAPTER 9 - BUILDING SERVICE AND FIRE PROTECTION EQUIPMENT: NO CHANGE
CHAPTER 10 - INTERIOR FINISH, CONTENTS, AND FURNISHES
10.2.3.1
INTERIOR WALL AND CEILING FINISH MATERIALS TESTED IN ACCORDANCE
WITH NFPA 286.
10.2.3.1.1
INTERIOR WALL AND CEILING FINISH MATERIALS SHALL BE CLASSIFIED IN
ACCORDANCE WITH NFPA 286 AND COMPLY WITH 10.2.3.2.
10.2.3.1.2
MATERIALS TESTED IN ACCORDANCE WITH 10.2.3.1.1 AND COMPLYING
WITH 10.2.3.2 SHALL BE CONSIDERED ALSO TO COMPLY WITH THE
REQUIREMENTS OF CLASS A, CLASS B, OR CLASS C IN ACCORDANCE WITH 10.2.3.3
10.2.3.2.
(1) DURING THE 40 KW EXPOSURE, FLAMES SHALL NOT SPREAD TO THE CEILING.
(2) THE FLAME SHALL NOT SPREAD TO THE OUTER EXTREMITY OF THE SAMPLE
ON ANY WALL OR CEILING.
(3) FLASHOVER, AS DESCRIBED IN NFPA 286, SHALL NOT OCCUR.
(4) THE PEAK HEAT RELEASE RATE THROUGHOUT THE TEST SHALL NOT EXCEED
800 KW.
(5) FOR NEW INSTALLATIONS, THE TOTAL SMOKE RELEASED THROUGH-OUT THE
TEST SHALL NOT EXCEED 1000 M2.
10.2.3.3
WALL AND CEILING- CLASSIFICATIONS CHARACTERISTICS.
(1) CLASS A: FLAME SPREAD: 0-25; SMOKE DEV. : 0-450.
(2) CLASS B: FLAME SPREAD: 26-75; SMOKE DEV. : 0-450
(3) CLASS C: FLAME SPREAD: 76-200; SMOKE DEV. : 0-450
10.2.7.2
INTERIOR FLOOR- CLASSIFICATIONS CHARACTERISTICS:
(1) CLASS I: RAD FLUX: FIN .45 W/CM2
(2) CLASS II: RAD FLUX: FIN .22 W/CM2, AND MAX. .45 W/CM2
10.2.7.3
INTERIOR FLOOR FINISH- SHALL BE CLASSIFIED BASED ON NFPA 253 OR
ASTM E 648.
10.2.8.1
WALL AND CEILING FINISHES, WHERE APPROVED SPRINKLER SYSTEM INSTALLED:
CLASS C PERMITTED IN ANY LOCATION WHERE CLASS B IS REQ’D.
CLASS B PERMITTED IN ANY LOCATION WHERE CLASS A IS REQ’D.
10.2.8.2
FLOOR FINISHES, WHERE APPROVED SPRINKLER SYSTEM INSTALLED:
CLASS II PERMITTED IN ANY LOCATION WHERE CLASS I IS REQ’D.
NO CRITICAL RAD. FLUX PERMITTED IN ANY LOCATION WHERE CLASS II IS
REQ’D
20.3.5.3
AND NFPA 10 SECTION 9.9 FIRE EXTINGUISHERS ARE REQUIRED WITHIN
75’ OF ANY POINT IN THE SPACE.
- MAINTAIN ACCESSIBILITY TO EXISTING FIRE EXTINGUISHERS DURING CONSTRUCTION
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
VA FORM 08 - 6231
A
FULLY SPRINKLERED
U.S. Department of Veterans Affairs
B
C
D
E
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
EXP: 12/31/2023
A u to d e s k D o c s /F t W a y n e V
A
R e m o d e l C h a p e l/ F
F E
F t W a y n e
R e m o d e l C h a p e l_
B rv t
/3
/2
:5
:4
P
M
GI003
OVERALL CODE AND LIFE SAFETY
PLAN
20230901 Checker Author
REMODEL FORT WAYNE CHAPEL 610A4-22-203
FORT WAYNE, IN
BID DOCUMENTS
VA NORTHERN
INDIANA
HEALTHCARE
SYSTEM
Approved: Veteran's Affairs Medical Center
D
D D
AD401
AD401
AD401
AD401
AD401
STRIP WOODEN DISPLAY
FOR REFINISHING
VA TO REMOVE
ALTAR PRIOR TO
CONSTRUCTION
REMOVE SEATING
VA TO REMOVE PIANO
PRIOR TO CONSTRUCTION
REMOVE CARPET
REMOVE CARPET
REMOVE CARPET
REMOVE CARPET
REMOVE DOOR
AND FRAME
REMOVE DOOR AND FRAME
VA TO REMOVE PULPIT
PRIOR TO CONSTRUCTION
REMOVE PLANTS
REMOVE WALL BASE
THROUGHOUT ROOM
REMOVE WALL BASE
THROUGHOUT ROOM
REMOVE STAINED
GLASS - TYP.
REMOVE PEW
SEATING
REMOVE BUILT-IN WOOD SPEAKERS
REMOVE VCT -
SEE SPECS FOR
REMOVAL OF
ASBESTOS
REMOVE BUILT-IN
REMOVE BUILT-IN
STRIP WOODEN STAIRS
FOR REFINISHING
REMOVE MINI FRIDGE
SINKS TO REMAIN - SINK
BELOW MINI FRIDGE NOT
SHOWN FOR CLARITY
REMOVE WALL BASE
NO WORK IN
THIS AREAREMOVE CONFESSIONAL
OPENING
REMOVE CURTAIN
REMOVE CABINETS
AD401
TEMPORARY CONSTRUCTION BARRIER AND ZIPPER
DOOR - OPAQUE 10 MIL FIRE RETARDANT POLYETHYLENE
SHEET PLASTIC PER SPECIFICATION 01 35 26.
AD401
AD401
AD401
AD401
AD401
REMOVE 14' PENDANT LIGHT
REMOVE 14' PENDANT LIGHT
REMOVE 14' PENDANT LIGHT
REMOVE 14' PENDANT LIGHT
REMOVE 14' PENDANT LIGHT
REMOVE
DOWNLIGHT
REMOVE WIRELESS
ACCESS POINT
REMOVE WIRELESS
ACCESS POINT
REMOVE CAN LIGHTS
REMOVE WALL SCONCE
REMOVE WALL SCONCE
REMOVE CAN LIGHTS
REMOVE WALL SCONCE
REMOVE WALL SCONCE
REMOVE EXIT SIGN
REMOVE EXIT SIGN
REMOVE STAINED GLASS - TYP.
REMOVE 1' X 4'
DOWNLIGHTS
REMOVE BUILT-IN WOOD SPEAKERS
AD401
REMOVE BUILT-INS
REMOVE BUILT-INS
A. FOR ALL REMOVALS, THE GENERAL CONTRACTOR SHALL COORDINATE WITH ALL OTHER DISCIPLINES
B. ALL ITEMS INDICATED AS DASHED SHALL BE REMOVED. THIS INCLUDES ALL FINISHES, MATERIALS, AND ASSOCIATED FIXTURES NOT SPECIFICALLY CALLED OUT. CONTRACTOR SHALL COORDINATE ALL ASSOCIATED WORK BETWEEN ALL
TRADES.
C. HALF-TONED ITEMS INDICATE EXISTING CONSTRUCTION SHALL BE PROTECTED & REMAIN.
D. THE CONTRACTOR SHALL PROVIDE TEMPORARY SUPPORT FOR ITEMS NOT DEMOLISHED OR REMOVED AS REQUIRED UNTIL
PERMANENT SUPPORT IS PROVIDED IN THE FINAL CONSTRUCTION.
E. UTILITIES THAT REMAIN, WITHIN WALLS BEING DEMOLISHED, SHALL BE REROUTED AS REQUIRED TO FACILITATE THE NEW
PLAN CONFIGURATION.
F. AT PENETRATIONS, ALL UTILITY SYSTEM & OTHER COMPONENTS THAT ARE SCHEDULED FOR DISCONNECTION SHALL BE REMOVED IN THEIR ENTIRETY. CONTRACTOR SHALL NOT CAP AND ABANDON IN PLACE UNLESS SPECIFICALLY NOTED OTHERWISE. ANY FIRE RESISTIVE MEMBER OR THROUGH PENETRATIONS RESULTING FROM SUCH DEMOLITION WORK SHALL BE FIRESTOPPED OR SEALED IN ACCORDANCE WITH NFPA FOR THE NECESSARY RATING PROTECTIONS.
G. SEE ELECTRICAL DRAWINGS FOR REPLACEMENT OF ALL RECEPTACLE COVERPLATES.
H. ALL PAINT IS PRESUMED TO BE LEAD-BASED PAINT UNLESS NOTED OTHERWISE. ALL CEILING, GYPSUM BOARD WALLS, AND HOLLOW METAL DOOR FRAMES ARE PAINTED. SEE SPECIFICATIONS FOR HANDLING AND DISPOSAL REQUIREMENTS.
I. PROJECT REQUIRES ICRA CLASS IV REQUIREMENTS. SEE SPECIFICATION SECTION 01 35 26 SAFETY REQUIREMENTS FOR
MORE INFORMATION.
G E N E R A L D E M O L I T I O N N O T E S
K E Y P L A N
L E G E N D
2 HOUR FIRE BARRIER
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
VA FORM 08 - 6231
A
FULLY SPRINKLERED
U.S. Department of Veterans Affairs
B
C
D
E
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
EXP: 12/31/2023
A u to d e s k D o c s /F t W a y n e V
A
R e m o d e l C h a p e l/ F
F E
F t W a y n e
R e m o d e l C h a p e l_
B rv t
/3
/2
:5
:4
P
M
AD101
DEMOLITION FLOOR PLAN AND
REFLECTED CEILING PLAN
20230901 PQ TD
REMODEL FORT WAYNE CHAPEL 610A4-22-203
FORT WAYNE, IN
BID DOCUMENTS
VA NORTHERN
INDIANA
HEALTHCARE
SYSTEM
Approved: Veteran's Affairs Medical Center
N
1/4" = 1'-0"
DEMOLITION FLOOR PLAN
N
1/4" = 1'-0"
DEMOLITION REFLECTED CEILING PLAN
AD401
AD401
REMOVE WOOD DOOR AND FRAME
SANCTUARY LAMP TO REMAIN
REMOVE ROOM SIGN
REMOVE LIGHT SWITCHES
REMOVE DUPLEX OUTLETS
REMOVE DOWNLIGHTS
REMOVE 14' PENDANT LIGHT - TYP.
REMOVE WOOD DOOR
AND HM FRAME
REMOVE EXIT SIGNS
REMOVE WALL SCONCE
REMOVE DIFFUSER
REMOVE AND RELOCATE
HAND SANITIZER
REMOVE PUSH TO OPEN
REMOVE WALL BASE
REMOVE WALL BASE
REMOVE SWITCHES
PHONE TO REMAIN
REMOVE DIFFUSER
REMOVE DIFFUSER
REMOVE WALL SCONCE
REMOVE WOOD DOOR
AND HM FRAME
REMOVE WALL BASE
REMOVE EXISTING PLATFORM
STRIP WOODEN DISPLAY
FOR REFINISHING
REMOVE PLYWOOD AND TRIM
AD401
REMOVE SPEAKER
REMOVE LINEAR DIFFUSER
REMOVE SPEAKER
REMOVE LINEAR DIFFUSER
REMOVE STAINED GLASS
REMOVE LIGHT SWITCH
REMOVE DUPLEX OUTLET
REMOVE WALL BASE
REMOVE 14'-0" PENDENT LIGHT
REMOVE 2' X 2' DOWN LIGHT
VA TO REMOVE SANCTUARY LAMP
REMOVE WALL BASE
REMOVE DUPLEX OUTLET
REMOVE WOOD DOOR AND HM FRAME
AD401
STRIP WOODEN DISPLAY
FOR REFINISHING
REMOVE CARPET AT STAIRS
NOTE: ALTAR, PULPIT, AND PIANO NOT
SHOWN IN ELEVATIONS FOR CLARITY
REMOVE EXISTING PLATFORM
VA TO REMOVE TABERNACLE
REMOVE PLYWOOD AND TRIM
AD401
REMOVE STAINED GLASS
REMOVE WALL BASE
REMOVE 14' PENDANT LIGHT
REMOVE PORTION
OF WALL
REMOVE ALL WALL
MOUNTED ITEMS
TURN OVER TO THE VA
REMOVE DIFFUSER
AD401
AD401
AD401
REMOVE WOOD DOOR AND FRAME
REMOVE ROOM SIGN
REMOVE COVERPLATES
REMOVE DOWNLIGHTS
REMOVE 14' PENDANT LIGHT - TYP.
REMOVE WALL BASE
REMOVE WALL BASE
REMOVE STAINED GLASS
WINDOW - TYP.
REMOVE WALL SCONCE - TYP.
REMOVE LINEAR DIFFUSER - TYP.
REMOVE RECESSED WOODEN
DISPLAY AND ASSOCIATED TRIM
REMOVE THERMOSTAT
AND WIRING BACK TO UNIT
REMOVE EXISTING PLATFORM
REMOVE DIFFUSER
A. FOR ALL REMOVALS, THE GENERAL CONTRACTOR SHALL COORDINATE WITH ALL OTHER DISCIPLINES
B. ALL ITEMS INDICATED AS DASHED SHALL BE REMOVED. THIS INCLUDES ALL FINISHES, MATERIALS, AND ASSOCIATED FIXTURES NOT SPECIFICALLY CALLED OUT. CONTRACTOR SHALL COORDINATE ALL ASSOCIATED WORK BETWEEN ALL
TRADES.
C. HALF-TONED ITEMS INDICATE EXISTING CONSTRUCTION SHALL BE PROTECTED & REMAIN.
D. THE CONTRACTOR SHALL PROVIDE TEMPORARY SUPPORT FOR ITEMS NOT DEMOLISHED OR REMOVED AS REQUIRED UNTIL
PERMANENT SUPPORT IS PROVIDED IN THE FINAL CONSTRUCTION.
E. UTILITIES THAT REMAIN, WITHIN WALLS BEING DEMOLISHED, SHALL BE REROUTED AS REQUIRED TO FACILITATE THE NEW
PLAN CONFIGURATION.
F. AT PENETRATIONS, ALL UTILITY SYSTEM & OTHER COMPONENTS THAT ARE SCHEDULED FOR DISCONNECTION SHALL BE REMOVED IN THEIR ENTIRETY. CONTRACTOR SHALL NOT CAP AND ABANDON IN PLACE UNLESS SPECIFICALLY NOTED OTHERWISE. ANY FIRE RESISTIVE MEMBER OR THROUGH PENETRATIONS RESULTING FROM SUCH DEMOLITION WORK SHALL BE FIRESTOPPED OR SEALED IN ACCORDANCE WITH NFPA FOR THE NECESSARY RATING PROTECTIONS.
G. SEE ELECTRICAL DRAWINGS FOR REPLACEMENT OF ALL RECEPTACLE COVERPLATES.
H. ALL PAINT IS PRESUMED TO BE LEAD-BASED PAINT UNLESS NOTED OTHERWISE. ALL CEILING, GYPSUM BOARD WALLS, AND HOLLOW METAL DOOR FRAMES ARE PAINTED. SEE SPECIFICATIONS FOR HANDLING AND DISPOSAL REQUIREMENTS.
I. PROJECT REQUIRES ICRA CLASS IV REQUIREMENTS. SEE SPECIFICATION SECTION 01 35 26 SAFETY REQUIREMENTS FOR
MORE INFORMATION.
G E N E R A L D E M O L I T I O N N O T E S
K E Y P L A N
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
VA FORM 08 - 6231
A
FULLY SPRINKLERED
U.S. Department of Veterans Affairs
B
C
D
E
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
EXP: 12/31/2023
A u to d e s k D o c s /F t W a y n e V
A
R e m o d e l C h a p e l/ F
F E
F t W a y n e
R e m o d e l C h a p e l_
B rv t
/3
/2
:5
:4
P
M
AD401
DEMOLITION ELEVATIONS
20230901 PQ TD
REMODEL FORT WAYNE CHAPEL 610A4-22-203
FORT WAYNE, IN
BID DOCUMENTS
VA NORTHERN
INDIANA
HEALTHCARE
SYSTEM
Approved: Veteran's Affairs Medical Center
1/4" = 1'-0"
EAST - DEMOLITION SECTION / ELEVATION
1/4" = 1'-0"
NORTH - DEMOLITION SECTION / ELEVATION
1/4" = 1'-0"
SOUTH - DEMOLITION SECTION / ELEVATION
1/4" = 1'-0"
WEST - DEMOLITION SECTION / ELEVATION
60" MH
AE401
AE401
AE401
AE401
REFINISH WOOD STAIRS -
STAIN: ST-1
LVT1
RESIN PATTERNED WINDOW WITH
HINGES/MAGNETIC LATCH AND
BACKLIT WITH LED STRIPS
SEE ELEVATIONS ON SHEET AE401
6" - DECORATIVE FAUX WOOD
PROFILE BASE THROUGHOUT ROOM
FURR-OUT WALL - 5"
DECORATIVE PANELING/WAINSCOTING
REFINISH WOODEN DISPLAY -
STAIN: ST-1
FAUX WOOD RAILING
/A
E
4/AE601
801 SF
CHAPEL
252 SF
CHANCEL
194A
54 SF
MECHANICAL
194B
102 SF
CHAPLAIN
194A
194B
AE601
RESHAPE ALTAR PLATFORM TO
MATCH SHAPE OF CEILING ABOVE
PUSH TO OPEN OPERATOR
PLASTIC LAMINATE CASEWORK
15' - 4"
ROOM SIGN
ROOM SIGN
AE601
AE401
TEMPORARY CONSTRUCTION BARRIER
AND ZIPPER DOOR - OPAQUE 10 MIL
FIRE RETARDANT POLYETHYLENE
SHEET PLASTIC PER SPECIFICATION 01
35 26.
1'
VA TO PROVIDE
NEW ALTAR
AE401
ALTERNATE #1: PROVIDE DECORATIVE
PANEL/WAINSCOTING SYSTEM TO MATCH
ADJACENT WALL IN LIEU OF CASEWORK
NEW CASEWORK - SEE
ELEVATIONS
NEW CASEWORK - SEE
ELEVATIONS
INFILL WALL - SEE DETAIL 10/AE401
INFILL WALL - SEE DETAIL 10/AE401
AE401
AE101
VA TO PROVIDE NEW PULPIT
VA TO PROVIDE NEW PIANO
AE401
AE401
AE401
AE401
LED COVE LIGHTING
HALO LED
PENDENT LIGHT
LED COVE LIGHTING
LED COVE LIGHTING
LED COVE LIGHTING
LED COVE LIGHTING
LED STRIP LIGHTING
LED CAN LIGHT
LED CAN LIGHT
LED CAN LIGHT
LED CAN LIGHT
REPAIR SCALLOPED GYPSUM CEILING
FROM EXISTING LIGHT FIXTURE
REPAIR SCALLOPED GYPSUM CEILING
FROM EXISTING LIGHT FIXTURE
REPAIR SCALLOPED GYPSUM CEILING
FROM EXISTING LIGHT FIXTURE
REPAIR SCALLOPED GYPSUM CEILING
FROM EXISTING LIGHT FIXTURE
REPAIR SCALLOPED GYPSUM CEILING
FROM EXISTING LIGHT FIXTURE
EXIT SIGN
EXIT SIGN
REPAIR GYPSUM CEILING FROM
EXISTING LIGHT FIXTURE
LED CAN
LIGHT
WIRELESS
ACCESS POINT
WIRELESS ACCESS POINT
AE401
GYPSUM SOFFIT
AE601
LED CAN LIGHT
LED CAN
LIGHT
LED CAN LIGHT
CROWN MOLDING
TYP.
CROWN MOLDING
TYP.
AE601
801 SF
CHAPEL
10' - 0"
252 SF
CHANCEL
194A
10' - 0"
9' - 6"
54 SF
MECHANICAL
194B
102 SF
CHAPLAIN
9' - 0" 10' - 0"
EXISTING BULKHEAD
AT 8'-10" AFF
A. PARTITIONS/FURRING SHALL BE 3 5/8" COLD FORMED STEEL FRAMING AND 5/8" GYPSUM BOARD, UNLESS OTHERWISE NOTED.
B. REFER TO DEMOLITION DRAWINGS FOR WORK REQUIRED IN ADVANCE OF CONSTRUCTION AND COORDINATE ACCORDINGLY.
C. ALL WALL HUNG CASEWORK AND EQUIPMENT ATTACHED TO WALLS SHALL BE ANCHORED TO FIRE RETARDANT TREATED WOOD BLOCKING ANCHORED BETWEEN STUDS UNLESS OTHERWISE NOTED. BLOCKING SHALL BE CONTINUOUS AND
LOCATED AT BOTTOM AND TOP OF EQUIPMENT.
D. SOUND ATTENUATION BATTS (SAB) ARE TO BE PLACED IN ALL PARTITIONS WHICH ENCLOSE A ROOM UNLESS NOTED
OTHERWISE.
E. PROJECT REQUIRES ICRA CLASS IV REQUIREMENTS. SEE SPECIFICATION SECTION 01 35 26 SAFETY REQUIREMENTS FOR
MORE INFORMATION.
G E N E R A L N O T E S
A. ALL VERTICAL FACES OF SOFFITS OR BULKHEADS SHALL BE FINISHED TO MATCH ADJACENT SURFACES.
B. ALL GYPSUM BOARD CEILINGS SHALL BE PAINTED P-1, UNLESS OTHERWISE NOTED.
G E N E R A L C E I L I N G N O T E S
K E Y P L A N
L E G E N D
2 HOUR FIRE BARRIER
1/4" PLYWOOD WITH WOOD
SCREWS AT 16" O.C.
FRT 2x4 WOOD SLEEPER AT 16" O.C.
LVT-1 - SEE FINISH LEGEND
CPT-2 - SEE FINISH LEGEND
V
IF4
EXISTING STRUCTURE BELOW
ALUMINUM STUD CLIP
1/2" FRT PLYWOOD WITH
WOOD SCREWS AT 16" O.C.
1/8" SMOOTH FRP PANEL - ADHERE
AND SCREW TO PLYWOOD
EDGING PROFILE FOR RESILIENT
FLOOR COVERING
BOD: SCHLUTER-VINPRO-STEP-R
AE101
FRT 2x4 WOOD STUDS AT 16" O.C.
LVT-1 - SEE FINISH LEGEND
9' - 9"
FRT BLOCKING AS REQUIRED
FOR RADIUS, TYP.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
VA FORM 08 - 6231
A
FULLY SPRINKLERED
U.S. Department of Veterans Affairs
B
C
D
E
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
EXP: 12/31/2023
A u to d e s k D o c s /F t W a y n e V
A
R e m o d e l C h a p e l/ F
F E
F t W a y n e
R e m o d e l C h a p e l_
B rv t
/3
/2
:2
:5
P
M
AE101
FLOOR PLAN AND REFLECTED
CEILING PLAN
20230901 PQ TD
REMODEL FORT WAYNE CHAPEL 610A4-22-203
FORT WAYNE, IN
BID DOCUMENTS
VA NORTHERN
INDIANA
HEALTHCARE
SYSTEM
Approved: Veteran's Affairs Medical Center
N
1/4" = 1'-0"
FLOOR PLAN
N
1/4" = 1'-0"
REFLECTED CEILING PLAN
1 1/2" = 1'-0"
ALTAR PLATFORM SECTION
1/2" = 1'-0"
ALTAR PLATFORM FRAMING PLAN
AE401
AE401
LED COVE LIGHTING - TYP.
HALO LED PENDENT LIGHT
STRIP LED LIGHTING
DOOR AND FRAME
OUTLET AND COVERPLATE
DECORATIVE LINEAR DIFFUSER
EXIT SIGN - CENTERED
ABOVE DOOR
SWITCHES AND COVER PLATE
6" - DECORATIVE FAUX
WOOD PROFILE BASE
DECORATIVE LINEAR
DIFFUSER
EXIT SIGN - CENTERED
ABOVE DOOR
DECORATIVE
PANELING/WAINSCOTING
RESIN PATTERNED WINDOW WITH
HINGES/MAGNETIC LATCH AND
BACKLIT WITH LED STRIPS
PUSH TO OPEN
SWITCHES AND COVERPLATE
HR-1 FAUX WOOD AND
STAINLESS STEEL RAILING -
SEE FINISH LEGEND
9' - 2" 8" 3' - 8" 8" 3' - 0" 8" 3' - 8" 8" 8' - 10"
5'
ROOM SIGN
SOFFIT
WP-1 WP-1 WP-1
WP-3 WP-3 WP-3
WP-3 WP-3 WP-3
WP-4
WP-3
P-2 P-2
WP-2 WP-2WP-2
P-2
P-2
WP-4
WP-4
AE401
WP-4
REFINISH WOODEN
DISPLAY - STAIN: ST-1
194194A193
AE101
4NEW ALTAR PLATFORM
CM-1CM-1CM-1 CM-1
2" C
LR
AE401
AE401
AE401
DECORATIVE LINEAR DIFFUSER DECORATIVE LINEAR DIFFUSER
INFILL WALL - SEE DETAIL 10/AE401INFILL WALL - SEE DETAIL 10/AE401
LIGHT SWITCH AND COVERPLATE
DUPLEX OUTLET AND
COVERPLATE
DUPLEX OUTLET AND COVERPLATE
REFINISH WOODEN DISPLAY - STAIN: ST-1
LED COVE LIGHTING
HALO LED PENDENT LIGHT
2' - 4"
FAUX WOOD AND STAINLESS
STEEL RAILING
FURR-OUT WALL - 5"
DECORATIVE
PANELING/WAINSCOTING
RESIN PATTERNED WINDOW
WITH HINGES/MAGNETIC LATCH
AND BACKLIT WITH LED STRIPS
EXIT SIGN CENTERED
ABOVE DOOR
AE401
1'
P-2 P-2
WP-4 WP-4
LVT-1 AT RISERS
FAUX WOOD RAILING
WP-4 WP-4
WP-3
WP-1
WP-2
P-2 P-2
WP-3 WP-3
WP-3
WP-3
WP-1
WP-2
WP-3
CROWN MOLDING
CROWN MOLDING
PLASTIC LAMINATE CASEWORK
AE401
NOTE: ALTAR, PULPIT, AND PIANO NOT
SHOWN IN ELEVATIONS FOR CLARITY
NEW ALTAR PLATFORM - SEE DETAIL 3/AE101
CM-1 CM-1
VA TO REINSTALL SANCTUARY LAMP
VA TO REINSTALL TABERNACLE
NEW CURTAIN HOOKS ON
BOTH SIDES OF DISPLAY
AE401
AE401
AE401
VERIFY CEILING HEIGHT
DECORATIVE LINEAR DIFFUSER
FURR-OUT WALL - 5"
DECORATIVE
PANELING/WAINSCOTING
RESIN PATTERNED WINDOW
WITH HINGES/MAGNETIC LATCH
AND BACKLIT WITH LED STRIPS
PATCH WALL DAMAGE FROM WALL MOUNTED OBJECTS
FURR-OUT WALL - 5"
DECORATIVE
PANELING/WAINSCOTING
RESIN PATTERNED WINDOW
WITH HINGES/MAGNETIC LATCH
AND BACKLIT WITH LED STRIPS
14' - 0"
6' - 4" 8" 6' - 8" 6' - 8" 8" 6' - 4"
WP-1
WP-3
WP-3
WP-3
P-2
WP-2
WP-4
CM-1
WP-1
WP-3
WP-3
P-2
WP-2
WP-4
CM-1
P-2
CM-1
PLASTIC LAMINATE CASEWORK
5'
SS-1
ALTERNATE #1: PROVIDE DECORATIVE
PANEL/WAINSCOTING SYSTEM TO MATCH
ADJACENT WALL IN LIEU OF CASEWORK
RELOCATED HAND SANITIZER
WP-3
AE401
AE401
LED COVE LIGHTING - TYP.
HALO LED PENDENT LIGHT
STRIP LED LIGHTING
INFILL WALL - SEE DETAIL 10/AE401
DOOR AND FRAME
DUPLEX OUTLET AND
COVERPLATE
6" - DECORATIVE FAUX
WOOD PROFILE BASE
RESIN PATTERNED WINDOW
WITH HINGES/MAGNETIC LATCH
AND BACKLIT WITH LED STRIPS
DECORATIVE LINEAR DIFFUSER
DECORATIVE
PANELING/WAINSCOTING
FAUX WOOD RAILING
AE401
TYP.
AE401
9 3/8" 8" 3' - 8" 8" 3' - 0" 8" 3' - 8" 8" 3' - 0" 8" 3' - 8" 8" 3' - 0" 8" 3' - 8" 8" 1' - 2"
ROOM SIGN
SOFFIT
WP-1WP-1WP-1
WP-3
WP-3WP-3WP-3
WP-4
WP-3
P-2P-2
WP-2WP-2 WP-2
P-2
WP-4
WP-3 WP-3
WP-3 WP-3
WP-1WP-1
WP-2 WP-2
WP-1WP-1
WP-2WP-2
CM-1
P-2
CM-1CM-1
WP-4 WP-4
WP-4
REFINISH WOODEN
DISPLAY - STAIN: ST-1
AE401
AE401
194B
NEW ALTAR PLATFORM -
SEE DETAIL 4/AE101
CM-1
2" C
LR
TAPE BOTTOM WITH MESH
TAPE AND PLASTER WELD
INDIRECT COVE LIGHT LEDGE.
GYPSUM BOARD - ALIGN COVE
LIGHT LEDGE WITH CEILING
ANGLED LED STRIP LIGHT -
SEE ELECTRICAL DRAWINGS
CUT OFF SCREWS TO NOT
INTERFERE WITH LIGHTS
ATTACH LIGHT LEDGE TO EXISTING
FRAMING. REMOVE EXISTING
GYPSUM AS NECESSARY
5 5/16"
1/
2"
EXISTING SCALLOPED CEILING
CONTRACTOR TO VERIFY EXISTING
FRAMING AND STRUCTURE.
LED STRIP LIGHTING AND DIFFUSER
3 5/8" COLD FORMED METAL FRAMING
RESIN PATTERNED WINDOW AND FRAME
HINGE AND MAGNETIC LATCH
EXISTING GYPSUM WALL
WP-3 TRIM - SEE
FINISH LEGEND
5/8" GYPSUM BOARD
6" COLD FORMED
METAL FRAMING
7 3/16"
WP-3 - TRIM TO FIT
WP-3 - TRIM TO FIT
6" COLD FORMED METAL FRAMING
WP-2 - SEE FINISH LEGEND
EXISTING GYPSUM WALL
WP-3 TRIM - SEE
FINISH LEGEND
5/8" GYPSUM BOARD
3 5/8" COLD FORMED
METAL FRAMING
WP-3 - TRIM TO FIT
4'
0"
5'
AE401
6" 8"
4" 4"
8" 2'
P-2
CM-1
WP-3
WP-2
WP-1
WP-2
WP-3
WP-4
4'
6"
EXISTING GYPSUM
BOARD SURFACE
WP-3 - TRIM
TO FIT
AE401
WP-4
WP-2 TRIM
WP-2 TRIM
WP-1 PANEL
DIFFUSER ATTACHED
TO EXISTING DUCTS
DIFFUSER ATTACHED
TO EXISTING DUCTS
LED STRIP LIGHTING
AND DIFFUSER
HINGE AND MAGNETIC LATCH
EXISTING GYPSUM
BOARD SURFACE
RESIN PATTERNED WINDOW
6"
8"
4"
6"
WP-4 WP-3 WP-2 CM-1
13/16"
13/16"
13/16"
5 1/2"
P R O F I L E L E G E N D
E Q
E Q
1' - 6"
SHELF
SHELF
SS-1
WP-3 - TRIM
TO FIT
CM-1
WP-4
WP-3
1'
4'
(2) LAYERS
3/4" PLYWOOD
WP-2
WP-1
WP-2
*ALL CASEWORK IS LOCKABLE.
NOTES:
A. PARTITIONS/FURRING SHALL BE 3 5/8" COLD FORMED STEEL FRAMING AND 5/8" GYPSUM BOARD, UNLESS OTHERWISE NOTED.
B. REFER TO DEMOLITION DRAWINGS FOR WORK REQUIRED IN ADVANCE OF CONSTRUCTION AND COORDINATE ACCORDINGLY.
C. ALL WALL HUNG CASEWORK AND EQUIPMENT ATTACHED TO WALLS SHALL BE ANCHORED TO FIRE RETARDANT TREATED WOOD BLOCKING ANCHORED BETWEEN STUDS UNLESS OTHERWISE NOTED. BLOCKING SHALL BE CONTINUOUS AND
LOCATED AT BOTTOM AND TOP OF EQUIPMENT.
D. SOUND ATTENUATION BATTS (SAB) ARE TO BE PLACED IN ALL PARTITIONS WHICH ENCLOSE A ROOM UNLESS NOTED
OTHERWISE.
E. PROJECT REQUIRES ICRA CLASS IV REQUIREMENTS. SEE SPECIFICATION SECTION 01 35 26 SAFETY REQUIREMENTS FOR
MORE INFORMATION.
G E N E R A L N O T E S
A. ALL VERTICAL FACES OF SOFFITS OR BULKHEADS SHALL BE FINISHED TO MATCH ADJACENT SURFACES.
B. ALL GYPSUM BOARD CEILINGS SHALL BE PAINTED P-1, UNLESS OTHERWISE NOTED.
G E N E R A L C E I L I N G N O T E S
K E Y P L A N
8"
4 7/8"
EXISTING STRUCTURE ABOVE
EXISTING GYPSUM BOARD
5/8" GYPSUM BOARD
3 5/8" 20 GA. CFS FRAMING
EXISTING FRAMING
EXISTING GYPSUM BOARD
5/8" TYPE X GYPSUM BOARD
2 1/2" 20 GA. COLD FORMED
METAL FRAMING
ALIGN FACE WITH EXISTING
E Q
E Q
*ALL CASEWORK IS LOCKABLE.
NOTES:
1' - 6" V.I.F.
MAGNETIC LATCH
BLOCKING AS REQUIRED -
SEE PHOTOS BELOW FOR
EXISTING BLOCKING
ADJUSTABLE SHELVING
EXISTING CLAY
MASONRY UNIT WALL
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
VA FORM 08 - 6231
A
FULLY SPRINKLERED
U.S. Department of Veterans Affairs
B
C
D
E
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
EXP: 12/31/2023
A u to d e s k D o c s /F t W a y n e V
A
R e m o d e l C h a p e l/ F
F E
F t W a y n e
R e m o d e l C h a p e l_
B rv t
/3
/2
:5
:5
P
M
AE401
ELEVATIONS, SECTIONS, AND
DETAILS
20230901 PQ TD
REMODEL FORT WAYNE CHAPEL 610A4-22-203
FORT WAYNE, IN
BID DOCUMENTS
VA NORTHERN
INDIANA
HEALTHCARE
SYSTEM
Approved: Veteran's Affairs Medical Center
1/4" = 1'-0"
EAST - SECTION / ELEVATION
1/4" = 1'-0"
NORTH - SECTION / ELEVATION
1/4" = 1'-0"
SOUTH - SECTION / ELEVATION
1/4" = 1'-0"
WEST - SECTION / ELEVATION
3" = 1'-0"
COVE LIGHTING DETAIL - TYPICAL
1 1/2" = 1'-0"
VERTICAL MOLDING - UPPER SECTION
1 1/2" = 1'-0"
VERTICAL MOLDING - LOWER SECTION
1" = 1'-0"
WAINSCOTING SECTION DETAIL
1" = 1'-0"
WAINSCOTING SECTION DETAIL
1/2" = 1'-0"
BACK CASEWORK SECTION
3" = 1'-0"
SOFFIT DETAIL
1" = 1'-0"
WALL INFILL - TYPICAL
1/2" = 1'-0"
CASEWORK SECTION
EXISTING WOOD FRAMING / BLOCKING
TRIM TO BE REMOVED AND REPLACED
REFINISH WOODEN DISPLAY
SLIDING DOORS TO BE
REMOVED, REFINISHED, AND
REINSTALLED
CURTAIN HOOKS TO BE
REMOVED AND REPLACED
EXISTING BLOCKING
TRIM TO BE REMOVED
AND REPLACED
EXISTING WOOD
FRAMING / BLOCKING
3' - 8"
4'
0"
PATTERNED RESIN
BACK FRONT
4'
4" 4"
4" 3' - 0" 4"
TYPE 1
SEE SCHEDULE
S E
E S
C H
E D
U L E
2" 2"
TYPE 2
SEE SCHEDULE
S E
E S
C H
E D
U L E
2" 2"
1 15/16" VARIES VARIES
REFER TO WALL
TYPE
DOUBLE STUDS
BACK TO BACK
CONTINUOUS
SEALANT BOTH
SIDES HOLLOW METAL FRAME
JAMB ANCHORS
/4
WP-3
WP-1
F S
S E
E S
C H
E D
U L E
SEE SCHEDULE
S E
E S
C H
E D
U L E
SEE SCHEDULE
4" 22"
PATTERNED
RESIN
FLUSH STAINED GLASS
4' - 0"2' - 0"
1'
1'
1'
2'
SHELVING
MINI
REFRIGERATOR
SHELVING
SHELVING
2'
8" FILLER PANEL
TALL CLOSET TALL CLOSET
FILLER PANEL
AE601
4' - 0"4' - 0"
AE601
AE601
9'
TALL CLOSET
WALL CABINETS
P-2
4" UNDERCOUNTER
DRAWERS
REFINISH WOOD STAIRS - STAIN ST-1
*ALL CASEWORK IS LOCKABLE.
ALL CASEWORK FACES SHALL BE PL-1
NOTES:
2'
0"
AE601
1-1/4" DIA.
CLOSET ROD
SHELVING
FILLER PANEL
SHELVING
TALL CLOSET
6"
8'
0"
8" 8"
8" 6'
9'
1' - 2"
5'
3/
4"
1/ 2"
3'
0"
8"
9'
4'
2'
/4
4"
UNDERCOUNTER
DRAWER
2' - 0"
WALL
CABINET
2'
0"
FILLER
PANEL
TALL CLOSET
BEYOND
LED LIGHT
E Q
E Q
E Q
A B C
D E F
NOTE: CEILING AND SOFFIT NOT SHOWN IN
RENDERING FOR CLARITY. ALL CASEWORK WITHIN
THIS ROOM IS FULL HEIGHT TO EXISTING SOFFIT.
SHELVING
FILLER PANEL
SHELVING
SHELVING
SHELVING
(3) ADJUSTABLE SHELVES
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
VA FORM 08 - 6231
A
FULLY SPRINKLERED
U.S. Department of Veterans Affairs
B
C
D
E
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
EXP: 12/31/2023
A u to d e s k D o c s /F t W a y n e V
A
R e m o d e l C h a p e l/ F
F E
F t W a y n e
R e m o d e l C h a p e l_
B rv t
/3
/2
:5
:5
P
M
AE601
DOOR SCHEDULE AND
CASEWORK DETAILS
20230901 PQ TD
REMODEL FORT WAYNE CHAPEL 610A4-22-203
FORT WAYNE, IN
BID DOCUMENTS
VA NORTHERN
INDIANA
HEALTHCARE
SYSTEM
Approved: Veteran's Affairs Medical Center
DOOR SCHEDULE
DOOR #
PANEL FRAME DETAILS
FIRE
RATING HW#
NO. OF
LEAF
DOOR
TYPE MATERIAL
DIMENSION
TYPE MATERIAL HEAD JAMBW H T
193 1 F SCWD 2' - 8" 6' - 8" 1 3/4" 1 HM - - - 1
194 2 S SCWD 5' - 0" 7' - 0" 1 3/4" 2 HM - - - 2
194A 2 S SCWD 5' - 0" 7' - 0" 1 3/4" 2 HM - - - 2.1
194B 1 F SCWD 2' - 8" 6' - 8" 1 3/4" 1 HM - - - 1
1" = 1'-0"
TYPICAL WINDOW ELEVATON
D O O R S C H E D U L E N O T E S
1. SEE HARDWARE SPECIFICATION 08 71 00 FOR HARDWARE SETS.
2. ALL DOOR FRAMES SHALL RECEIVE PAINT TYPE P-3. SEE FINISH LEGEND.
3. ALL DOORS TO BE WD-1. SEE FINISH LEGEND.
4. ALL CYLINDERS WILL BE KEYED INTO EXISTING BEST GREAT GRAND MASTER KEY SYSTEM BY THE VA. PROVIDE REMOVABLE CORE CYLINDER HOUSING.
CYLINDERS SHALL BE 7 PIN TYPE.
3" = 1'-0"
DOOR HEAD AND JAMB DETAIL
1/2" = 1'-0"
CASEWORK CLOSET
1/2" = 1'-0"
CASEWORK DESK AND CLOSET
1/2" = 1'-0"
CASEWORK SECTION DETAIL
1/2" = 1'-0"
CASEWORK SECTION DETAIL
1/2" = 1'-0"
PATTERNED RESIN OPTIONS
NTS
CHAPLAIN CASEWORK 3D
1/2" = 1'-0"
CASEWORK SECTION DETAIL
BASIS OF DESIGN: 3FORM KODA XT - SUBMIT MANUFACTURER'S PRODUCT LITERATURE,
INSTALLATION INSTRUCTIONS, AND DETAILS FOR SHOP DRAWING REVIEW
60" MH
AE401
AE401
AE401
AE401
/A
E
4/AE601
CHAPEL
CPT-1 P-1
P-2PB-1
CHANCEL
194A
CPT-2 P-1
P-2PB-1
CHAPLAIN
LVT-1 P-1
P-2RB-1
MECHANICAL
194B
AE601
AE601
LVT-1 AT RISERS
LVT-1 AT RISER
F I N I S H L E G E N D
MARK DESCRIPTION BASIS OF DESIGN STYLE/ COLOR COMMENTS
LVT-1 LUXURY VINYL TILE SHAW COMMERCIAL
BRANCHING OUT 4256V
56730 RAVINE OAK
6" X 48" - PLATFORM AND OFFICE
P-2 PAINT - TYPE 2 SHERWIN WILLIAMS ALABASTER SW7008
WP-1 WALL PANELING ACROVYN WOODGRAINS 1352-FOSSIL TEAK WALL PANELS
P-1 PAINT - TYPE 1 SHERWIN WILLIAMS WHITE GENERAL CEILING PAINT - LATEX EGGSHELL
WALL PAINT - LATEX EGGSHELL
P-3 PAINT - TYPE 3 SHERWIN WILLIAMS WORLDLY GRAY SW7043 DOOR FRAMES
PL-1 PLASTIC LAMINATE MATCH ACROVYN WP-1 MATCH 1352-FOSSIL TEAK CHANCEL CASEWORK
CPT-1 CARPET TILE PATCRAFT Z6474-INSTINSIC - 00522-MOOD DU JOUR ASHLAR - 24" X 24" RUNNING N/S - CHAPEL
HR-1 HANDRAIL CONTRACTOR TO DETERMINE MATCH WOODGRAINS 1351-SMOKEY ELM
FLOOR MOUNTED FAUX WOOD AND
STAINLESS STEEL RAIL
WP-2 WALL PANELING ACROVYN WOODGRAINS 1351-SMOKEY ELM WALL PANEL TRIM AND FRAME
CPT-2 CARPET TILE PATCRAFT Z6474-INSTINSIC - 00522-MOOD DU JOUR ASHLAR - 24" X 24" RUNNING E/W - CHANCEL
RB-1 RUBBER BASE JOHNSONITE A530 - 66 EITHER OR USED WITH LVT-1
CM-1 CROWN MOLDING ACROVYN
EDWARDS SMOOTH
WOODGRAINS 1352-FOSSIL TEAK
ALL WALLS IN THE CHAPEL WITH
WAINSCOTING
WP-3 WALL PANELING ACROVYN WOODGRAINS 1352-FOSSIL TEAK HORIZONTAL AND VERTICAL BOARDS
SS-1 SOLID SURFACE CORIAN CLAM SHELL BACK COUNTERTOP
WP-4 FAUX WOOD PROFILE BASE WOODGRAINS 1352-FOSSIL TEAK 6" PROFILE BASE - SEE DETAIL ACROVYN
ST-1 WOOD STAIN CONTRACTOR TO DETERMINE MATCH WOODGRAINS 1352-FOSSIL TEAK ALL REFINISHED WOOD SURFACES
WD-1 SOLID WOOD DOOR ACROVYN WOODGRAINS 1352-FOSSIL TEAK ALL WOOD DOORS
FLOOR FINISH
WALL BASE
F I N I S H T A G L E G E N D
ROOM NAME
WALL FINISH
CEILING FINISH
WP-4 WP-3 WP-2 CM-1
13/16"
13/16"
13/16"
5 1/2"
P R O F I L E L E G E N D
/A
E
4/AE601
5' - 0"
2' - 0"
3' - 5" 3' - 5"
A. FURNITURE PROVIDED BY VA.
B. CONTRACTOR TO PROVIDE SHOP DRAWINGS FOR CASEWORK AND WAINSCOTING.
G E N E R A L N O T E S
K E Y P L A N
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
VA FORM 08 - 6231
A
FULLY SPRINKLERED
U.S. Department of Veterans Affairs
B
C
D
E
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
EXP: 12/31/2023
A u to d e s k D o c s /F t W a y n e V
A
R e m o d e l C h a p e l/ F
F E
F t W a y n e
R e m o d e l C h a p e l_
B rv t
/3
/2
:2
:0
P
M
AI101
FINISH PLAN AND SCHEDULE
20230901 PQ TD
REMODEL FORT WAYNE CHAPEL 610A4-22-203
FORT WAYNE, IN
BID DOCUMENTS
VA NORTHERN
INDIANA
HEALTHCARE
SYSTEM
Approved: Veteran's Affairs Medical Center
N
1/4" = 1'-0"
FINISH FLOOR PLAN
F I N I S H S C H E D U L E
ROOM NAME
ROOM
NUMBER FLOOR CEILING WALL FINISH WALL BASE
WALL FINISH CEILING
HEIGHTN E S W
DATA 176A
CHAPLAIN 193 LVT-1 P-1 P-2 RB-1 P-2 P-2 P-2 P-2 9' - 6"
CHAPEL 194 CPT-1 P-1 P-2 PB-1 P-2 / WP-1 / WP-2 / WP-3 P-2 / WP-1 / WP-2 / WP-3 P-2 / WP-1 / WP-2 / WP-3 P-2 / WP-1 / WP-2 / WP-3 10' - 0"
CHANCEL 194A CPT-2 P-1 P-2 PB-1 P-2 P-2 P-2 P-2 10' - 0"
MECHANICAL 194B ETR ETR ETR ETR ETR ETR ETR ETR
N
1/4" = 1'-0"
FURNITURE PLAN
C
C
E
FLEXIBLE CONDUIT CONNECTION
SUBSCRIPT: WP - WEATHERPROOF, GF - GROUND FAULT CIRCUIT
INTERRUPTER
FLUSH FLOOR MOUNTED NEMA 5-20 DUPLEX RECEPTACLE
UNLESS NOTED OTHERWISE
NEMA 5-20 DUPLEX RECEPTACLE MOUNTED 18" AFF
UNLESS NOTED OTHERWISE
JUNCTION BOX
NON-FUSED DISCONNECT SWITCH. SIZE AS SHOWN
FUSED DISCONNECT SWITCH. SIZE FUSES FOR EQUIPMENT
BASED ON MANUFACTURERS RECOMMENDATIONS
SURFACE MOUNTED PANELBOARD OR AUTOMATIC TRANSFER
SWITCH AS INDICATED.
MOTOR
J
WP/GF
POWER
CONCEALED OR OPEN
UNDERGROUND
WIRINGLIGHTING
EXTERIOR SITE
FLUSH FLOOR MOUNTED NEMA 5-20 QUAD RECEPTACLE
UNLESS NOTED OTHERWISE
RECESSED MOUNTED PANELBOARD
RECEPTACLE, (NEMA CONFIGURATION AS NOTED)
GROUNDING
ABBREVIATIONS
NEW PAD MOUNTED TRANSFORMER
EXISTING COMMUNICATIONS MANHOLE
NEW COMMUNICATIONS MANHOLE
EXISTING POLE MOUNTED LIGHTING FIXTURE
NEW POLE MOUNTED LIGHTING FIXTURE
EXISTING UNDERGROUND ELECTRICAL LINE.
EXISTING OVERHEAD ELECTRICAL LINE.
EXISTING UNDERGROUND COMMUNICATION LINE
EXISTING OVERHEAD COMMUNICATION LINE
NEW ELECTRICAL HANDHOLE
NEW BOLLARD LIGHT FIXTURE.
EUP
EP
EUC
EC
GRID COUNTERPOISE CONDUCTOR
LIGHTNING PROTECTION ROOF CONDUCTOR
CONNECTION TO GROUND
LIGHTNING PROTECTION DOWN CONDUCTOR
RC
DC
G
AIR TERMINAL
GROUNDING ROD
STATIC GROUNDING RECEPTACLE
UP
US
UC
NEW UNDERGROUND PRIMARY
NEW UNDERGROUND SECONDARY
NEW UNDERGROUND COMMUNICATIONS
EXISTING SECTIONALIZER CABINETS
T
H
M
M
FIRE ALARM
DATA/TELEPHONE
DATA/TELEPHONE OUTLET. PROVIDE (2) CAT 6a CABLES WITHIN
CONDUIT OR OTHER APPROVED RACEWAY FROM OUTLET TO
NEAREST IT CLOSET OR CABLE TRAY. SUBSCRIPT INDICATES # OF
DATA CABLES.
NURSE CALL - A/V
PA SPEAKER, CEILING MOUNTED
NURSE CALL STATION
PS = PATIENT STATION
TS = TOILET STATION WITH PULL STRING
SW = SHOWER STATION
DS = DUTY STATION
MS = MASTER STATION
SS = STAFF STATION
NURSE CALL STATION
ZL = ZONE INDICATING DOME LIGHT FOR CORRIDOR
NURSE CALL SIGNAL
CARD READER
PANIC BUTTON
HANDICAP DOOR MOTOR
HANDICAP DOOR OPERATOR
ELECTRIC LATCH
SECURITY CAMERA CCTV - DOME
DURESS/PANIC ALARM
SECURITY / ACCESS CONTROL
TV BEDSIDE TELEVISION
PILOT LIGHT / CHIME
PUSHBUTTON
SMOKE DETECTOR
F FIRE ALARM SPEAKER/STROBE
FIRE ALARM STROBE
F FIRE ALARM SENDING STATION
S R
FIRE ALARM CONTROL RELAY. C- CONTROL I-INPUT.
DUCT DETECTOR. "R" INDICATES RETURN DUCT. "S"
INDICATES SUPPLY DUCT.
AM
C a
OS
1' x 4' FIXTURE. UPPERCASE INDICATES TYPE PER THE FIXTURE SCHEDULE.
LOWER CASE LETTER "a" INDICATES SWITCH ZONE.
OS
LC#
2' x 4' FIXTURE.
WALL MOUNTED FIXTURE.
INDUSTRIAL FIXTURE.
WALL MOUNTED FIXTURE.
EXIT SIGN WITH DIRECTIONAL ARROWS AS INDICATED
RECESSED FIXTURE, DOWNLIGHT
3-WAY, 20 AMP, 125 VOLT TOGGLE SWITCH MOUNTED 42" AFF.
4-WAY, 20 AMP, 125 VOLT TOGGLE SWITCH MOUNTED 42" AFF.
WALL MOUNTED OCCUPANCY SENSOR WITH OVERRIDE SWITCH
CEILING MOUNTED OCCUPANCY SENSOR
20 AMP, 125 VOLT SINGLE-POLE TOGGLE SWITCH MOUNTED 42" AFF.
a - CONTROLS LIGHTS WITH "a" DESIGNATION
LIGHTING CONTROLLER
D
20A, 125V DIMMER SWITCH MOUNTED 42" AFF
2' x 2' FIXTURE.
A1 a
EMERGENCY LIGHT
2' x 4' FIXTURE. SOLID FILL INDICATES FIXTURE ON LIFE SAFETY OR
EMERGENCY CIRCUIT.
(WHERE GENERATOR POWER IS NOT AVAILABLE PROVIDE A UNIT
BATTERY AT 1400 LM)
2' x 4' FIXTURE. DIAGONAL FILL INDICATES FIXTURE ON CRITICAL
CIRCUIT.
MD MOTION DETECTOR
CC
CR
EL
AP
X
PB
K
HD
HA
PP
WIRELESS ACCESS POINT
KEY PAD
COMBINATION STARTER
NEMA 5-20 DUPLEX RECEPTACLE MOUNTED 44" AFF
UNLESS NOTED OTHERWISE
NEMA 5-20 DOUBLE DUPLEX RECEPTACLE MOUNTED 18" AFF
UNLESS NOTED OTHERWISE
POWER CONNECTION
N
PS
N
KC KEY PAD / CARD READER
6-30R
NEMA 5-20 DUPLEX RECEPTACLE WITH USB CHARGER MOUNTED 18" AFF
UNLESS NOTED OTHERWISE
NEMA 5-20 DUPLEX SPLIT RECEPTACLE MOUNTED 18" AFF
UNLESS NOTED OTHERWISE
NEMA 5-20 SIMPLEX RECEPTACLE MOUNTED 18" AFF
UNLESS NOTED OTHERWISE
S
FACP
FIRE ALARM CONTROL PANEL
FAA
FIRE ALARM ANNUNCIATOR PANEL
F FIRE ALARM CHIME/STROBE
FIRE ALARM SPEAKER/STROBE CEILDING MOUNTEDS
F COMBINATION HORN/STROBE WITH SENDING STATIONF
HEAT DETECTOR
R DUCT REMOTE TEST STATION
K KNOX BOX
D DOOR HOLDER
DS CEILING MOUNTED DAYLIGHT SENSOR
PC PHOTOCELL
S
H
A AMPERE
AC ABOVE COUNTER, 42"AFF UNLESS OTHERWISE INDICATED
ADA MERICANS WITH DISABILITIES ACT
AFF ABOVE FINISHED FLOOR - TO BOTTOM
AL ALUMINUM
1/C ONE CONDUCTOR
C CONDUIT
CB CIRCUIT BREAKER
CKT CIRCUIT
CU COPPER
(E) EXISTING
EF EXHAUST FAN
(EM) EMERGENCY LIGHTING
EMT ELECTRICAL METALLIC TUBING
EWC ELECTRIC WATER COOLER
FACP FIRE ALARM CONTROL PANEL
FM FREQUENCY MODULATION
GFI GROUND FAULT CIRCUIT INTERRUPTER
GFP GROUND FAULT PROTECTION
HACR HEATING AIR CONDITIONING REFRIGERATION
HP HORSEPOWER
HPS HIGH PRESSURE SODIUM
HT HEIGHT
HZ HERTZ
IDS INTRUSION DETECTION SYSTEM
J JUNCTION BOX
KWH KILOWATT HOUR
LED LIGHT EMITTING DIODE
MCB MAIN CIRCUIT BREAKER
MH MOUNTING HEIGHT - TO CENTER
MLO MAIN LUGS ONLY
MTD MOUNTED
NEC NATIONAL ELECTRICAL CODE
NF NON FUSED
NO. NUMBER
OS OCCUPANCY SENSOR
PH PHASE
PIR PASSIVE INFRARED
RGS RIGID GALVANIZED STEEL
SM SINGLE MODE
SPD SURGE PROTECTIVE DEVICE
TTB TELEPHONE TERMINAL BOARD
TV TELEVISION
UNO UNLESS NOTED OTHERWISE
V VOLT
VA VOLTAMPERE
VVD VARIABLE VOLUME DAMPER
W WATTS
WP WEATHERPROOF
XFMR TRANSFORMER
CEILING MOUNT
D2 FIXTURE
AIRCRAFT CABLE
AIRCRAFT CABLE
D2 FIXTURE
CEILING MOUNT
CEILING
MIN: 11"
MAX: 13''
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
VA FORM 08 - 6231
A
FULLY SPRINKLERED
U.S. Department of Veterans Affairs
B
C
D
E
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
09/01/2023
A u to d e s k D o c s /F t W a y n e V
A
R e m o d e l C h a p e l/ F
F E
F t W a y n e
R e m o d e l C h a p e l_
B rv t
/3
/2
:5
:5
P
M
E001
LEGEND
20230901 JB IA
REMODEL FORT WAYNE CHAPEL 610A4-22-203
FORT WAYNE, IN
BID DOCUMENTS
VA NORTHERN
INDIANA
HEALTHCARE
SYSTEM
Approved: Veteran's Affairs Medical Center
LIGHTING FIXTURE SCHEDULE
IMAGE TYPE DESCRIPTION FFE_Voltage LOAD (VA) LAMP(S)
LUMINOUS
FLUX
COLOR
TEMPERATURE
MOUNTING
S-SURFACE
R-RECESSED
CH-CHAIN HUNG
P-PENDANT
A1 LED COVE LIGHT, 0-10V DIMMING 120 V 54 LED 2400 lm 4000 K COVE
A1 (EM) LED COVE LIGHT, 0-10V DIMMING 120 V 54 LED 2400 lm 4000 K COVE
A2 LED TASK LIGHTING 18 LED SURFACE
A3 LED STRIP LIGHT, 0-10V DIMMING, COLOR CHANGING 120 V 6 LED 5700 lm 4000 K PENDANT
D1 6" LED DOWNLIGHT, CLEAR REFLECTOR, SEMI-SPECULAR, 0-10V DIMMING, MEDIUM DISTRIBUTION. 0-10V
DIMMING
18 1250 lm 4230 K RECESSED
D1 (EM) 6" LED DOWNLIGHT, CLEAR REFLECTOR, SEMI-SPECULAR, 0-10V DIMMING, MEDIUM DISTRIBUTION. 0-10V
DIMMING
18 LED 1250 lm 4230 K RECESSED
D2 FRAME ACCORD OVAL LED PENDANT, MATTE BLACK. 0-10V DIMMING LED PENDANT
D3 LED STRIP LIGHTING. 0-10V DIMMING LED SURFACE
X1 SINGLE FACE EXIT SIGN WITH STENCIL RED LETTERS, WHITE BODY 4 RED LED 0 lm 0 K SURFACE
NTS
Chandelier Detail
120/277 V
120/277 V
2987 lm
2987 lm
3500 K
120/277 V
120/277 V
120/277 V
120/277 V
LED
2605 lm 4000 K
D/3
GF
D/3
D/3
D/3
D/3
D/3
D/3
D/3
D
36" MH
D
60" MH
D D
D D
A1
A1 (EM)
A1
A1
A1
A1
A1
A1
A1
X1
X1
A1
A3
A3
A3
A3
A3
A3
TYP
TYP
TYP
HA
HD
HA
AE401
D1D1
D1 D1
D1
D1 (EM)
D1
D1 (EM)
D1
D1 (EM)
D1
D1 (EM)
D1 D1 D2
D1
D1
D1
D3
A2
TALL CABINET
b a a a ab c c c c c c c c a c c c c d d d d d d
11 11
11 11 a b c d b c a d
TYP
TYP
TYP
CHAPEL
AP
AP
27 27
TELEPHONE
REMOVE 14' PENDANT LIGHT
REMOVE 14' PENDANT LIGHT
REMOVE 14' PENDANT LIGHT
REMOVE 14' PENDANT LIGHT
REMOVE 14' PENDANT LIGHT
REMOVE 2' X 2'
LIGHT
REMOVE 1' X 4'
LIGHT
REMOVE WIRELESS
ACCESS POINT
REMOVE WIRELESS
ACCESS POINT
REMOVE CAN LIGHTS
REMOVE WALL
SCONCE
REMOVE WALL
SCONCE
REMOVE CAN LIGHTS
REMOVE WALL
SCONCE
REMOVE WALL
SCONCE
REMOVE EXIT
SIGN
REMOVE 1' X 4'
LIGHT
REMOVE SPEAKERS
REMOVE 1' X 4'
LIGHT
REMOVE
LIGHT SWITCH
HA
HD
HA 4
REMOVE
LIGHT SWITCH
TYP
TYP
CHAPEL
EM
AP
AP
DATA
176A
CHAPEL
DATA DROP
DATA CLOSET
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
VA FORM 08 - 6231
A
FULLY SPRINKLERED
U.S. Department of Veterans Affairs
B
C
D
E
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
09/01/2023
A u to d e s k D o c s /F t W a y n e V
A
R e m o d e l C h a p e l/ F
F E
F t W a y n e
R e m o d e l C h a p e l_
B rv t
/3
/2
:5
:5
P
M
EL101
ELECTRICAL DEMO AND NEW
WORK PLAN
20230901 BS IA
REMODEL FORT WAYNE CHAPEL 610A4-22-203
FORT WAYNE, IN
BID DOCUMENTS
VA NORTHERN
INDIANA
HEALTHCARE
SYSTEM
Approved: Veteran's Affairs Medical Center
N
1/4" = 1'-0"
ELECTRICAL FLOOR PLAN
D R A W I N G N O T E S :
1 TYPE A3 LED COLOR CHANGING LIGHTS MOUNTED BEHIND STAINED GLASS WINDOW. (4) 3' LIGHTS IN EACH WINDOW, TOP
BOTTOM AND BOTH SIDES. CONNECT WITH MAINTAINED CIRCUIT IN DEMO PHASE.
2 LED LIGHT FIXTURE MOUNTED IN COVE. ANGLED UPWARD. SEE ARCHITECTURAL DRAWINGS FOR MOUNTING LOCATION
AND DETAILS. CONNECT WITH MAINTAINED CIRCUIT IN DEMO PHASE.
3 REMOVE WALL SCONCE AND SURFACE WIREMOLD RACEWAY AND WIRING TO NEXT DEVICE. PROTECT AND MAINTAIN EMERGENCY CIRCUIT TO BE USED IN THE INSTALLATION OF NEW EMERGENCY FIXTURES IN NEW WORK PHASE.
4 REMOVE ADA ACTUATOR BUTTON.
5 REMOVE ADA DOOR OPENING MOTOR LOCATED ABOVE DOOR. PRESERVE CIRCUIT FOR USE IN NEW WORK.
6 INSTALL ADA ACTUATOR BUTTON AND CONNECT TO NEW ADA DOOR OPENING MOTOR ABOVE DOOR.
7 INSTALL ADA DOOR OPENING MOTOR ABOVE DOOR TO OPERATE BOTH DOORS IN DOORWAY AND ACTIVATED BY ADA
DOOR ACTUATOR. USE MAINTAINED EXISTING CIRCUIT FROM DEMO PHASE.
8 INSTALL LED STRIP LIGHT UNDER CABINET. MOUNT DRIVER INSIDE TALL CABINET AT OR NEAR THE TOP. ROUTE WIRING HIDDEN IN CABINET FROM DRIVER TO LED STRIP. CONNECT TO D1 LIGHT FIXTURE CIRCUIT IN ROOM.
9 TYPE D2 LED LED CHANDELIER MOUNTED WITH AIRCRAFT CABLE. SEE SHEET AE401 FOR HANGING HEIGHT. SEE SHEET
E001 FOR D2 FIXTURE DETAIL. CONNECT USING PRESERVED EXISTING CIRCUIT.
10 TYPE D3 LED LIGHTS MOUNTED AROUND SOFFIT IN CEILING.
This is the start of the file's text. The full file is on GovTribe.