Asbestos Survey Report.pdf
PDF 3 MB Posted
- Solicitation number
- 36C25020B0059
About this file
This notice announces a forthcoming solicitation for corrective facility condition deficiencies interior work. The Veterans Affairs Cincinnati VAMC intends to release solicitation number 36C25020B0059 for project number 539-20-211 with a projected value between $500,000 and $1,000,000. The work must be completed within 180 days of the notice to proceed. The solicitation will be a 100% set-aside for small businesses with an emphasis on service-disabled veteran-owned small businesses. The NAICS code is 238220 for the business size standard of $16.5 million. Interested offerors should register on beta.sam.gov where the full solicitation will be posted on or around August 10, 2020. Successful offerors must comply with VA security requirements and be registered and verified on vip.vetbiz.gov and sam.gov. Offerors must demonstrate no more than three serious OSHA or EPA violations and an experience modification rate of 1.0 or below. Bonds will be required in the form of bid, payment, and performance bonds.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| MH111.pdf | ||
| ED000A - BASEMENT ELECTRICAL DEMO PLAN- AREA A.pdf | ||
| AE111.pdf | ||
| FX101 - FIRE PROTECTION BASEMENT PLANS.pdf | ||
| 114121 Walk-In Coolers and Freezers.pdf | ||
| AD112.pdf | ||
| Site Visit Sign In Sheet.pdf | ||
| EP000A - BASEMENT ELECTRICAL NEW WORK - AREA A.pdf | ||
| 2nd Sign in Sheet.pdf | ||
| 230511 Common Work Results for HVAC.pdf | ||
| MD101.pdf | ||
| AE101.pdf | ||
| 36C25020B0059 0002.docx | DOCX document | |
| AD111.pdf | ||
| 36C25020B0059 0001.docx | DOCX document | |
| Corbin Russwin Locksets Sole Source Justification - Redacted.pdf | ||
| S02 RFI Form.docx | DOCX document | |
| S02 Contractor EMR Certification Form.docx | DOCX document | |
| 539-20-211_Specifications (Combined).pdf | ||
| 100_ CD Drawings_Combined -07202020.pdf | ||
| 36C25020B0059.docx | DOCX document | |
| Wage Determination.pdf |
Show all 22
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Asbestos Survey
VA Project: Correct FCA Deficiencies – B64
VA Project No.: 539-20-211
Fort Thomas VA Medical Center
1000 Fort Thomas Avenue
Fort Thomas, KY 41075
January 30, 2020
Terracon Project No. N1197176
Prepared for:
FFE, Inc.
Cincinnati, Ohio 45246
Prepared by:
Terracon Consultants, Inc.
Cincinnati, Ohio 45226
Terracon Consultants, Inc., 611 Lunken Park Dr ive, C incinnat i , OH 45226
P (513) 321-5816 terracon.com
FEE, Inc.
438 Springfield Pike, Suite C
Cincinnati, Ohio 45215
Attn: Mr. Clint Weekley, PE, CBCP, LEED AP President
T: 513.522.0956
E: clint.weekley@ffe-serv.com
Re: Asbestos Survey
VA Project: Correct FCA Deficiencies – B64
VA Project No.: 539-20-211
Fort Thomas VA Medical Center
1000 Fort Thomas Avenue
Fort Thomas, KY, 41075
Dear Mr. Weekley, Terracon Consultants, Inc. (Terracon) is pleased to submit the attached report for the above-referenced renovation project to FFE, Inc. (Client). The purpose of this report is to present the results of an asbestos survey which was performed at the site on January 14, 2020, and in general accordance with our proposal number PN1197176, dated May 10, 2019. We understand that this survey was requested for the purpose of a planned renovation project which will have impacts at various locations in Building 64 (B64) at the Fort Thomas VA Medical Center (FTVAMC).
Asbestos-containing materials (ACM) were identified as a result of the survey. Please refer to the attached report for detail.
Terracon appreciates the opportunity to provide this service to FFE, Inc. If you have any questions regarding this report, please contact the undersigned at 513-321-5816.
Sincerely, Terracon Consultants, Inc.
Lem Weyer Joseph A. Tussey, CHMM
Environmental Technician Sr. Associate / Group Manager
KY Asbestos Management Planner
Correct FCA Deficiencies – B64 ■ Fort Thomas VAMC January 30, 2020 ■ Terracon Project No. N1197176
TABLE OF CONTENTS
EXECUTIVE SUMMARY .......................................................................................................................... i
1.0 INTRODUCTION
1.1 Project Objective
1.2 Reliance
2.0 PROJECT DESCRIPTION
3.0 FIELD ACTIVITIES
3.1 Visual Assessment
3.2 Physical Assessment
3.3 Sample Collection
3.4 Sample Analysis
4.0 REGULATORY OVERVIEW
5.0 FINDINGS AND RECOMMENDATIONS
6.0 LIMITATIONS/GENERAL COMMENTS
APPENDIX A IDENTIFIED ASBESTOS-CONTAINING MATERIALS BY HOMOGENEOUS AREA (HA)
APPENDIX B ASBESTOS SURVEY SAMPLE & RESULTS SUMMARY
APPENDIX C ASBESTOS ANALYTICAL LABORATORY DATA
APPENDIX D LICENSES AND CERTIFICATIONS
APPENDIX E PROJECT / SAMPLE LOCATION DRAWINGS
APPENDIX F PHOTOS
Responsive ■ Resourceful ■ Reliable i
EXECUTIVE SUMMARY
Terracon Consultants, Inc. (Terracon) conducted an asbestos survey which was specifically limited to within the boundaries and intent of the planned renovation project entitled “Correct FCA
Deficiencies – FTD Interior Deficiencies” for Building 64 (B64) at the Fort Thomas VA Medical
Center (FTVAMC). We understand that this survey was requested prior to renovation for the purpose of compliance with the EPA National Emission Standards for Hazardous Air Pollutants
(NESHAP) regulation (40 CFR Part 61, Subpart M). The survey included identifying and sampling suspect asbestos-containing materials (ACM) for laboratory analysis, and providing information regarding the identity, location, condition, and approximate quantities of ACM (if any) pertaining to specific building components which may be impacted by the planned renovation as indicated on Client-provided drawings (see Appendix E). The survey was performed on January 14, 2020 by a Commonwealth of Kentucky Department of Environmental Protection, Division of Air Quality-licensed Asbestos Management Planner. The survey was conducted in general accordance with our proposal number PN1197176, dated May 10, 2019, and the sampling protocols established in USEPA 40 Code of Federal Regulations (CFR) Part 763, Subpart E, known as the Asbestos
Hazard Emergency Response Act (AHERA).
Specific to the subject renovation project areas and building systems indicated on Client-provided drawings (see Appendix E) and based on the analytical results of the collected samples, the materials listed below were identified to contain asbestos.
ACM Description Material Locations % and Type
Asbestos Condition
Estimated
Quantity*
12” x12” White Floor Tile with Black Specks and
Black Mastic Women’s Locker Room (Room 026)
Floor Tile: 2.6% Chrysotile, Mastic: 10% Chrysotile
Good 600 Square Feet (SF)
12” x12” White Floor Tile with Black Streaks and
Black Mastic Men’s Locker Room (Room 025A)
Floor Tile: 3.1% Chrysotile, Mastic: 10% Chrysotile
Good 450 SF
Black Mastic Under Non- Asbestos-Containing
12”x12” White Floor tile with Grey Specks
Linen Closet (Room 018) 4.2% Chrysotile Good 175 SF
*Estimated quantities listed above are based on a cursory field evaluation, and actual quantities may vary significantly, especially if
ACMs are present outside of the renovation areas, and in hidden and/or inaccessible areas not evaluated as part of this survey. This is not a bidding document and contractors would be responsible for drawing their own conclusions on quantities present.
A sample summary is included in Appendix B and the laboratory analytical report is included in
Appendix C. Sample locations/renovation project drawings are included in Appendix E and example photos of the identified ACM are included in Appendix F.
If the identified ACM will be impacted by the renovation project, the materials will need to be removed prior to renovation by a state-licensed asbestos abatement contractor in accordance
Responsive ■ Resourceful ■ Reliable ii with applicable federal, state, and local asbestos regulations, as well as per the VA’s abatement specification requirements.
Please note that additional suspect ACM (not sampled as part of this survey) could be present in inaccessible/hidden areas.
Responsive ■ Resourceful ■ Reliable 1
ASBESTOS SURVEY
VA Project: Correct FCA Deficiencies –B64
VA Project No. 539-20-211
Fort Thomas VA Medical Center
1000 Fort Thomas Avenue
Fort Thomas, KY 41075
1.0 INTRODUCTION
Terracon Consultants, Inc. (Terracon) conducted an asbestos survey specifically limited to within the boundaries and intent of the planned renovation project entitled “VA Project: Correct FCA
Deficiencies- FTD Interior Deficiencies” in Building 64 (B64) of the Fort Thomas VA Medical
Center (FTAMC). The survey was performed at the site on January 14, 2019 by a Commonwealth of Kentucky Department of Environmental Protection, Division of Air Quality-licensed Asbestos
Management Planner. Accessible building components and areas intended to be renovated were surveyed based upon Client-provided renovation plans. Homogeneous areas of suspect asbestos-containing materials (ACM) were visually identified and documented. Although reasonable effort was made to survey accessible suspect materials, additional suspect but un-sampled materials could be located in walls, in voids, or in other concealed areas. Suspect ACM samples were collected in general accordance with the sampling protocols outlined in USEPA 40
Code of Federal Regulations (CFR) Part 763, Subpart E, known as the Asbestos Hazard
Emergency Response Act (AHERA). Samples were delivered to an accredited laboratory for analysis by Polarized Light Microscopy (PLM).
1.1 Project Objective
We understand that this survey was requested for the purposes of a future planned renovation project. Please note that asbestos surveys are required prior to renovation or demolition to satisfy requirements of the USEPA 40 CFR Part 61, Subpart M, the National Emission Standards for
Hazardous Air Pollutants (NESHAP) regulation (as well as the state NESHAP equivalent).
1.2 Reliance
This report is for the exclusive use of FFE, Inc. (Client) for the project being discussed. Reliance by any other party on this report is prohibited without written authorization of Terracon and FFE, Inc. Reliance on this report by FFE, Inc. and all authorized parties will be subject to the terms, conditions, and limitations stated in the proposal and the agreement between Terracon and FFE, Inc.
Responsive ■ Resourceful ■ Reliable 2
2.0 PROJECT DESCRIPTION
In general, the planned renovation project includes replacement of the speaker system throughout the hallways; impacts to electrical closets, first floor bathrooms (108 and 165), basement bathrooms/locker rooms, and other various rooms; and the replacement of the basement walk-in coolers/freezers in B64 at the Fort Thomas VA Medical Center (FTVAMC). Client-provided drawings which indicate the areas and systems being impacted by the renovation are shown on the drawings included in Appendix E.
3.0 FIELD ACTIVITIES
The survey was conducted by Mr. Lemuel Weyer who is an EPA-accredited and Commonwealth of Kentucky Department of Environmental Protection, Division of Air Quality-licensed Asbestos
Management Planner. A copy of his current Kentucky Asbestos Management Planner credential is attached as Appendix D. The survey was conducted in general accordance with the sample collection protocols established in USEPA 40 CFR Part 763, Subpart E, Section 763.86, AHERA.
A summary of survey activities is provided below.
3.1 Visual Assessment
Survey activities were initiated with visual observation of accessible areas and accessible building components pertaining to the renovation project to identify homogeneous areas of suspect ACM.
A homogeneous area (HA) consists of building materials that appear similar throughout in terms of color and texture with consideration given to the date of application.
Please note that additional suspect ACM (not sampled as part of this survey) may be present in
3.2 Physical Assessment
A physical assessment of each HA of suspect ACM was conducted to assess the friability and condition of the materials. A friable material is defined by the USEPA as a material which can be crumbled, pulverized, or reduced to powder by hand pressure when dry. Friability was assessed by physically touching suspect materials.
3.3 Sample Collection
Based on results of the visual observation, bulk samples of suspect ACM were collected in general accordance with USEPA AHERA sampling protocols. Samples of suspect materials were collected from randomly selected locations in each homogeneous area. Bulk samples were
Responsive ■ Resourceful ■ Reliable 3 collected using wet methods as applicable to reduce the potential for fiber release. Samples were placed in sealable containers and labeled with unique sample numbers using an indelible marker.
The selection of sample locations and frequency of sampling were based on Terracon’s observations and the assumption that like materials in the same area are homogeneous in content.
Terracon collected a total of 116 bulk samples from 38 homogeneous areas of suspect ACM. A summary of suspect ACM samples collected during the survey is included as Appendix B.
3.4 Sample Analysis
Bulk samples were submitted under chain of custody to International Asbestos Testing
Laboratories (IATL) of Mount Laurel, New Jersey for analysis by PLM with dispersion staining techniques per USEPA methodology 600/R-93/116. The percentage of asbestos, where applicable, was determined by microscopic visual estimation. For samples identified by PLM to contain <10% asbestos, the additional point count method was utilized. IATL is accredited under the National Voluntary Laboratory Accreditation Program (NVLAP), accreditation number 101165-
0.
4.0 REGULATORY OVERVIEW
The asbestos NESHAP (40 CFR Part 61, Subpart M) regulates asbestos fiber emissions and asbestos waste disposal practices. The asbestos NESHAP regulation also requires the identification and classification of existing ACM according to friability prior to demolition or renovation activity. Friable ACM is a material containing more than 1% asbestos that, when dry, can be crumbled, pulverized, or reduced to powder by hand pressure. All friable ACM is considered regulated asbestos containing material (RACM).
The asbestos NESHAP regulation classifies material subject to demolition or renovation as either
RACM, Category I non-friable ACM, or Category II non-friable ACM. RACM includes all friable
ACM (pre-disturbance), along with Category I non-friable ACM that becomes friable (during disturbance), and Category I non-friable ACM subject to sanding, grinding, cutting, or abrading, or Category II non-friable ACM with a high probability of becoming crumbled, pulverized, or reduced to powder by forces expected to act on the material during disturbance. Category I non-friable ACM are exclusively asbestos-containing packings, gaskets, resilient floor coverings, and asphalt roofing products that contain more than 1% asbestos. Category II non-friable ACM are all other non-friable materials (other than Category I non-friable ACM) that contain more than 1% asbestos. Category II non-friable ACM generally includes (but is not limited to) cementitious material such as: cement pipes, cement siding (Transite™), cement panels, glazing, mortar, and grouts.
Responsive ■ Resourceful ■ Reliable 4
In Kentucky, the federal NESHAP regulation has been delegated to the state EPA and is administered under 401 Kentucky Administrative Regulation (KAR) 58:025. The Kentucky
Department for Environmental Protection (DEP), Division for Air Quality (DAQ) is responsible for administering and enforcing the federal and state NESHAP regulations as well as administering accreditations for asbestos professionals. NESHAP pre-renovation and pre-demolition notifications (are sent to the regional state EPA office). NESHAP pre-renovation (where >160 SF
/ 260 LF of friable ACM is removed) and pre-demolition notifications must be submitted to the
DAQ office 10 business days prior to project commencement. The Kentucky local regional DAQ office for the subject site is the Florence Region; 8020 Veterans Memorial Drive, Suite 110, Florence, KY 41042; telephone (859-525-4157); contact Mr. Clay Redmond
(clay.redmond@ky.gov).
The United States Occupational Safety and Health Administration (USOSHA) asbestos standard for construction (29 CFR 1926.1101) regulates workplace exposure to asbestos. The USOSHA standard requires that employee exposure to airborne asbestos must not exceed 0.1 fibers per cubic centimeter of air (0.1 f/cc) as an eight-hour time weighted average (TWA) and not exceed
1.0 fibers per cubic centimeter of air (1.0 f/cc) over a 30-minute time period known as an excursion limit (EL). The TWA and EL are known as USOSHA’s asbestos permissible exposure limits
(PELs). The USOSHA standard classifies construction and maintenance activities which could disturb ACM and specifies work practices and precautions which employers must follow when engaging in each class of regulated work.
5.0 FINDINGS AND RECOMMENDATIONS
Specific to the subject renovation project areas and building systems indicated on Client-provided drawings (see Appendix E) and based on the analytical results of the collected samples, the materials listed below were identified to contain asbestos.
ACM Description Material Locations % and Type
Asbestos Condition
Estimated
Quantity*
12” x12” White Floor Tile with Black Specks and Black
Mastic
Women’s Locker Room (Room 026)
Floor Tile: 2.6% Chrysotile, Mastic: 10% Chrysotile
Good 600 Square Feet (SF)
12” x12” White Floor Tile with Black Streaks and Black
Mastic
Men’s Locker Room (Room 025A)
Floor Tile: 3.1% Chrysotile, Mastic: 10% Chrysotile
Good 450 SF
Black Mastic Under Non- Asbestos Containing 12” x 12”
White Floor Tile with Grey Specks
Linen Closet (Room 018) 4.2% Chrysotile Good 175 SF
*Estimated quantities listed above are based on a cursory field evaluation, and actual quantities may vary significantly, especially if
ACMs are present outside of the renovation areas, and in hidden and/or inaccessible areas not evaluated as part of this survey. This is not a bidding document and contractors would be responsible for drawing their own conclusions on quantities present
Responsive ■ Resourceful ■ Reliable 5
A sample summary is included in Appendix B and the laboratory analytical report is included in
Appendix C. Sample locations/renovation project drawings are included in Appendix E and example photos of the identified ACM are included in Appendix F.
If the identified ACM will be impacted by the renovation project, the materials will need to be removed prior to renovation by a state-licensed asbestos abatement contractor in accordance with applicable federal, state, and local asbestos regulations, as well as per the VA’s abatement specification requirements.
Please note that additional suspect ACM (not sampled as part of this survey) could be present in
6.0 LIMITATIONS/GENERAL COMMENTS
The survey was project specific and limited to our understanding of the Client’s intended renovation project scope; this survey is not meant to be a comprehensive survey of the entire building/facility and may not have included all building systems/materials in the subject area. In addition, Terracon did not perform sampling which required demolition or destructive activities such as knocking large holes in walls, dismantling of equipment or removal of protective coverings
(including ceramic coverings, sampling would cause irreparable damage). Reasonable efforts to access suspect materials within known areas of restricted access (e.g., crawl spaces) were made;
however, confined spaces or areas which may pose a health or safety risk to Terracon personnel were not sampled. Sampling did not include suspect materials which could not be safely reached with available ladders/man-lifts.
This asbestos survey was conducted in a manner consistent with the level of care and skill ordinarily exercised by members of the profession currently practicing under similar conditions in the same locale. The results, findings, conclusions, and recommendations expressed in this report are based on conditions observed during our survey of the building. The information contained in this report is relevant to the date on which this survey was performed and should not be relied upon to represent conditions at a later date. This report has been prepared on behalf of and exclusively for use by FFE, Inc. for specific application to their project as discussed. This report is not a bidding document. Contractors or consultants reviewing this report must draw their own conclusions regarding quantities, further investigation or remediation deemed necessary. Terracon does not warrant the work of regulatory agencies, laboratories, or other third-parties supplying information which may have been used in the preparation of this report. No warranty, express or implied is made.
Responsive ■ Resourceful ■ Reliable 6
APPENDIX A
VA Project: Correct FCA Deficiencies- FTD Interior Deficiencies
VA Project No. 539-20-211
Fort Thomas VA Medical Center
1000 Fort Thomas Avenue
Fort Thomas, KY 41075
IDENTIFIED ASBESTOS-CONTAINING MATERIALS BY HOMOGENEOUS AREA (HA)
HA
No.
ACM Description Material Location
% and Type
Asbestos
EPA NESHAP
Classification Condition
Estimated
Quantity*
12” x12” White Floor Tile with Black Specks and Black Mastic
Women’s Locker Room (Room 026) Floor Tile: 2.6% Chrysotile
Mastic: 10% Chrysotile Category I Non-Friable Good 600 SF
12” x12” White Floor Tile with Black Streaks and
Black Mastic Men’s Locker Room (Room 025A)
Floor Tile: 3.1% Chrysotile Mastic: 10% Chrysotile
Category I Non-Friable Good 450 SF
Black Mastic Under Non- Asbestos Containing 12” x 12” White Floor Tile with
Grey Specks
Linen Closet (Room 018) 4.2% Chrysotile Category I Non-Friable Good 175 SF
See Appendix B for a summary of samples collected, Appendix C for detailed analytical results, Appendix E for a sample location drawings/renovation plans, and
Appendix F for example photos of the identified ACM.
*Estimated quantities listed above are based on a cursory field evaluation, and actual quantities may vary significantly, especially if ACMs are present outside of the planned renovation areas, and in hidden and/or inaccessible areas not evaluated as part of this survey. This is not a bidding document and contractors would be responsible for drawing their own conclusions regarding quantities present.
It should be noted that inaccessible/concealed suspect materials, other than those identified during this survey, may exist. Should additional suspect materials be uncovered prior to or during renovation activities, those materials must be assumed asbestos-containing until sampled by a state-licensed asbestos inspector and analysis refutes the positive assumption.
If the identified ACM will be impacted by the renovation, such materials would need to be properly removed, handled, and disposed in accordance with applicable federal and state EPA regulations, OSHA regulations, and per VA project specifications.
Responsive ■ Resourceful ■ Reliable 7
APPENDIX B
VA Project: Correct FCA Deficiencies- FTD Interior Deficiencies
VA Project No. 539-20-211
Fort Thomas VA Medical Center
1000 Fort Thomas Avenue
Fort Thomas, KY 41075
ASBESTOS SURVEY SAMPLE & RESULTS SUMMARY
Sample # Sample Material
Description Sample Location HA Location(s)
Results (% /
Type of
Asbestos) HA # SEQ. #
Tan Duct Mastic
Electrical Closet –
Room 276
Associated with
2nd and 3rd Floor
Duct Work
None Detected
(ND)
Electrical Closet-
Room 242d
ND
Electrical Closet-
Room 356
ND
Red Fire-Stop
Caulking
Electrical Closet –
Room 276 Penetrations in
Electrical Closet
Walls on 2nd and
3rd Floors
ND
Electrical Closet-
Room 242d
ND
Electrical Closet-
Room 356
ND
Drywall System:
Gypsum Board with
Joint Compound
Doorway of Room
2nd and 3rd Floor
Electrical Closets
Gypsum Board:
ND, Joint
Compound: ND
Northwest Corner of 242d
Gypsum Board:
ND, Joint
Compound: ND
Doorway of Room
Gypsum Board:
ND, Joint
Compound: ND
2’ x 2’ White Plain
Ceiling Tiles
Hallway near
Electrical Closet
253 Throughout 2nd
Floor
ND
Hallway Outside
Room 244
ND
Responsive ■ Resourceful ■ Reliable 8
Hallway Outside
Room 232
ND
Grey Duct Mastic
Hallway Outside
Room 200 Associated with
Various
Locations of Duct
Work throughout the Building
ND
Hallway Outside
Room 329
ND
Hallway Outside
Room 129
ND
White Encapsulant
Hallway Outside
Room 200 Associated with
Fiberglass Pipes
Throughout
Building
Encapsulant: ND, Fiberglass: ND
Hallway Near
Room 307a
Encapsulant: ND, Fiberglass: ND
Hallway Outside
Room 029
Encapsulant: ND, Fiberglass: ND
2’ x 2’ Ceiling Tiles with Small Fissures
Outside Offices
Throughout 3rd
Floor
ND
Hallway Outside
Room 307
ND
Hallway Outside
Room 336
ND
2’ x 2’ Ceiling Tiles with Large Fissures
Hallway Outside
Room 113
Throughout 1st
Floor and
Basement
ND
Hallway Outside
Room 101
ND
Hallway Outside
Room 031
ND
Tan Duct Mastic
Hallway Outside
Room123 Associated with
1st and
Basement Duct
Work
ND
Hallway Outside
Room 023
ND
Hallway Outside
Room 029
ND
10 28
1” x 1” Red and White
Ceramic Floor Tile with Mastic and Grout
Room 108-
Doorway to
Shower Area
Bathrooms 108, 156, 025
Ceramic: ND, Mastic: ND, Grout: ND
Responsive ■ Resourceful ■ Reliable 9
Room 108- Main
Doorway to
Bathroom
Ceramic: ND, Mastic: ND, Grout: ND
Room 156- Main
Doorway to
Bathroom
Ceramic: ND, Mastic: ND, Grout: ND
4” x 4” Tan Wall Tile with Yellow Mastic
Room 108-
Northeast Corner of Bathroom Area
Bathrooms 108 and 156
Ceramic: ND, Mastic: ND
Room 108-
Northeast Corner of Bathroom Area
Ceramic: ND, Mastic: ND
Room 156-
Northwest Corner of Room
Ceramic: ND, Mastic: ND
2’ x 2’ Ceiling Tile with
Small Fissures
Room 108- Middle of Room
Bathrooms 108 and 156
ND
Room 156- Middle of Room
ND
Room 156-
Northwest Corner
ND
Drywall System:
Gypsum Board with
Joint Compound
Room 108-
Northeast Corner of Bathroom Area
Bathrooms 108 and 156
Gypsum Board:
ND
Room 108-
Northeast Corner of Shower Area
Gypsum Board:
ND, Joint
Compound: ND
Room 156-
Northwest Corner of Center Dividing
Wall
Gypsum Board:
ND, Joint
Compound: ND
2’ x 2’ Drywall Ceiling
Tiles
Room 108-
Northwest Corner
Bathrooms 108 and 156 Shower
Areas
ND
Room 156-
Southeast Corner
ND
Room 156-
Southwest Corner
ND
15 43 White Encapsulant with Mastic
Room 108- Middle of Shower Area
Associated with
Fiberglass Pipes
Throughout
Encapsulant: ND, Fiberglass: ND, Mastic: ND
Responsive ■ Resourceful ■ Reliable 10
Room 108- Middle of Shower Area
Bathrooms 108 and 156
Encapsulant: ND, Fiberglass: ND, Mastic: ND
Room 156 Middle of Bathroom Area
Encapsulant: ND, Fiberglass: ND
Pipe Insulation and
Hard Fittings
North End of
Center Divider Wall in Room 156 Behind Walls in
Pipe Chases of
Bathrooms 108 and 156
Insulation: ND, Wrap: ND
North End of
Center Divider Wall in Room 156
Insulation: ND, Wrap: ND
North End of
Center Divider Wall in Room 156
Insulation: ND, Wrap: ND
Red Fire-Stop
Caulking
Room 108- Middle
North Wall Associated with
Penetrations in
Walls of
Bathrooms 108 and 156
ND
Room 108- Middle
North Wall
ND
Room 156-
Northeast Corner
ND
Plaster Walls and
Ceilings
Middle North Wall
Bathroom 156
ND
53 Middle North Wall ND
54 Northeast Corner ND
Fiberglass Reinforced
Plastic (FRP) Board with White Mastic
Doorway of Cooler
Room 007 Basement Walk-in Coolers.
Rooms 006, 007, 008, 010, 010A
FRP Board: ND, Mastic: ND
Doorway of Cooler
Room 010
FRP Board: ND, Mastic: ND
Doorway of Cooler
Room 010A
FRP Board: ND, Mastic: ND
6” x 6” Red Ceramic
Floor Tile with Mortar
Doorway of Cooler
Basement Walk-in Coolers.
Rooms 006, 007, 008, 010, 010A
Ceramic: ND, Mortar: ND
Doorway of Cooler
Ceramic: ND, Mortar: ND
Doorway of Cooler
Ceramic: ND, Mortar: ND
Responsive ■ Resourceful ■ Reliable 11
Multi-Sized (1” x 1” and 1” x 2”) Blue
Ceramic Floor Tile with Mastic and Grout
Doorway
Room 022
Ceramic: ND, Grout: ND
62 Doorway Ceramic: ND, Grout: ND
63 Northeast Corner Ceramic: ND, Grout: ND
4” x 4” Blue Wall Tile with Mastic and Grout
Southwest Corner
Room 022
Ceramic: ND, Mastic: ND, Grout: ND
65 Southwest Corner
Ceramic: ND, Mastic: ND, Grout: ND
66 Southwest Corner
Ceramic: ND, Mastic: ND, Grout: ND
4” x 4” White Wall Tile with Mastic and Grout
Southwest Corner
Southwest
Corner of 017
Ceramic: ND, Mastic: ND, Grout: ND
68 Southwest Corner
Ceramic: ND, Mastic: ND, Grout: ND
69 Southwest Corner
Ceramic: ND, Mastic: ND, Grout: ND
Unfinished Gypsum
Board
Southwest Corner
West Wall in
Room 017
Sample Not
Analyzed
71 Southwest Corner
Gypsum Board:
ND, White
Texture: ND
72 Northwest Corner
Gypsum Board:
ND, White
Texture: ND
1” x 1” Grey Floor Tile with Mastic and Grout
Doorway
Room 024
Ceramic: ND, Mastic: ND, Grout: ND
74 Doorway
Ceramic: ND, Mastic: ND, Grout: ND
75 Doorway
Ceramic: ND, Mastic: ND, Grout: ND
26 76 Plaster Walls and
Ceilings
Room 022-
Northwest Corner
Skim Coat: ND, Plaster: ND
Responsive ■ Resourceful ■ Reliable 12
Room 023-
Northeast Corner
Rooms 017, 022, 023, 024, 025 &
Skim Coat: ND, Plaster: ND
Room 017-
Doorway
Skim Coat: ND, Plaster: ND
Room 024-
Southwest Corner of Locker Room
Skim Coat: ND, Plaster: ND
Room 026-
Northeast Corner
Skim Coat: ND, Plaster: ND
12” x 12” Pink Floor
Tile with Yellow
Mastic
Southwest Corner
Room 023
Ceramic: ND, Mastic: ND
82 Northwest Corner Ceramic: ND, Mastic: ND
83 Northeast Corner Ceramic: ND, Mastic: ND
8” Tan Cove Base with Tan Mastic
Southwest Corner
Room 023
Cove Base: ND, Mastic: ND
85 Northwest Corner Cove Base: ND, Mastic: ND
86 Northeast Corner Cove Base: ND, Mastic: ND
Black Sink
Undercoating
Southwest Corner
Sink
Room 023
Southwest Sink
ND
Southwest Corner
Sink
ND
Southwest Corner
Sink
ND
2’ x 2’ Drywall Ceiling
Tiles
Northwest Corner
Room 023
ND
91 Northeast Corner ND
92 Southeast Corner ND
31 93 Tan Duct Mastic Middle of Room
Associated with
Duct Work
ND
Responsive ■ Resourceful ■ Reliable 13
Middle of Room
Throughout
Rooms 017, 022, 023, 024, 025 &
ND
Middle of Room
ND
White Duct Sealant
Middle of Room
Associated with
Room 023 Duct
Work
ND
Middle of Room
ND
Middle of Room
ND
12” x 12” White Floor
Tile with Black Specks and Black Mastic
Southeast Corner
Women’s
Restroom- 026
Floor Tile: 2.2%
Chrysotile by
Point Count
(PC), Mastic:
7.3% Chrysotile
PC
100 Northeast Corner
Floor Tile: 2.6%
Chrysotile PC, Mastic: 10%
Chrysotile
101 Southwest Corner
Floor Tile: 1.9%
Chrysotile PC, Mastic: 2.4%
Chrysotile PC
8” Black Cove Base with Brown Mastic
Southeast Corner
Women’s
Restroom- 026
Cove Base: ND, Mastic: ND
103 Northeast Corner Cove Base: ND, Mastic: ND
104 Southwest Corner Cove Base: ND, Mastic: ND
1” x 1” Tan Ceramic
Floor Tile with Mastic and Grout
Southwest of 026
Southwest
Corner of
Women’s
Restroom- 026
Ceramic: ND, Grout: ND, Mastic: ND
106 Southwest of 026
Ceramic: ND, Grout: ND, Mastic: ND
107 Southwest of 026
Ceramic: ND, Grout: ND, Mastic: ND
Responsive ■ Resourceful ■ Reliable 14
12” x12” White Floor
Tile with Black
Streaks and Black
Mastic
Northeast Corner
Men’s Locker
Room- Room
025A
Floor Tile: 3.1%
Chrysotile PC, Mastic: 8.3%
Chrysotile PC
109 Northwest Corner
Floor Tile: 2.0%
Chrysotile PC, Mastic: 10%
Chrysotile
110 Southeast Corner
Floor Tile: 1.8%
Chrysotile PC, Mastic: 10%
Chrysotile
4” x 4” Aqua Wall Tile with Mastic and Grout
Northeast Corner
Men’s Restroom-
Room 025
Ceramic: ND, Mastic: ND, 112 Northeast Corner Ceramic: ND, Mastic: ND, 113 Northwest Corner Ceramic: ND, Mastic: ND, 12” x 12” White Floor
Tile with Grey Specks and Black Mastic
Southwest Corner
Linen Closet-
Room 018
Floor Tile: ND, Mastic: 4.2%
Chrysotile PC
115 Northwest Corner
Floor Tile: ND, Mastic: 3.7%
Chrysotile PC
116 Southeast Corner Floor Tile: ND
Responsive ■ Resourceful ■ Reliable
APPENDIX C
ASBESTOS ANALYTICAL LABORATORY DATA
Lab No.: 6953376 Client No.: 1-01
Analyst Observation: Tan Mastic Client Description: Tan Duct Mastic
Location: Electrical Closet- Room 276 Facility:
Percent Asbestos:
None Detected
Percent Non-Asbestos Fibrous Material:
Percent Non-Fibrous Material:
Lab No.: 6953377 Client No.: 1-02
Location: Electrical Closet- Room 242d
Lab No.: 6953378 Client No.: 1-03
Location: Electrical Closet- Room 356
Lab No.: 6953379 Client No.: 2-04
Analyst Observation: Red Firestop Client Description: Red Fire-Stop Caulking
5 Fibrous Glass
Lab No.: 6953379(L2) Client No.: 2-04
Analyst Observation: Off-White Insulation
10 Cellulose
Lab No.: 6953380 Client No.: 2-05
Laboratory Director
Approved By:
Date Analyzed:
1/16/2020Date Received:
Analyst:
Please refer to the Appendix of this report for further information regarding your analysis.
Signature:
Amy Latham
01/28/2020 Frank E. Ehrenfeld, III
9000 Commerce Parkway Suite B Mt. Laurel, New Jersey 08054
Telephone: 856-231-9449 Email: customerservice@iatl.com
CERTIFICATE OF ANALYSIS
Client: Terracon
611 Lunken Park Drive Cincinnati OH 45226
1/29/2020Report Date:
Report No.: 607942 - PLM Project: Fort Thomas VAMC Project No.: N1197176
PLM BULK SAMPLE ANALYSIS SUMMARY
Client: TER940
Dated : 1/29/2020 1:29:01 Page 1 of 43
Lab No.: 6953380(L2) Client No.: 2-05
Lab No.: 6953381 Client No.: 2-06
Lab No.: 6953381(L2) Client No.: 2-06
Lab No.: 6953382 Client No.: 3-07
Analyst Observation: White Drywall Client Description: Drywall System: Gypsum Board With Joint Compound
Location: Doorway Of Room 276
3 Fibrous Glass
Lab No.: 6953382(L2)
Analyst Observation: White Joint Compound
Lab No.: 6953382(L3)
Analyst Observation: Composite
5 Cellulose
Laboratory Director
Approved By:
Date Analyzed:
1/16/2020Date Received:
Analyst:
Please refer to the Appendix of this report for further information regarding your analysis.
Signature:
Amy Latham
01/28/2020 Frank E. Ehrenfeld, III
9000 Commerce Parkway Suite B Mt. Laurel, New Jersey 08054
Telephone: 856-231-9449 Email: customerservice@iatl.com
CERTIFICATE OF ANALYSIS
Client: Terracon
611 Lunken Park Drive Cincinnati OH 45226
1/29/2020Report Date:
Report No.: 607942 - PLM Project: Fort Thomas VAMC Project No.: N1197176
PLM BULK SAMPLE ANALYSIS SUMMARY
Dated : 1/29/2020 1:29:01 Page 2 of 43
Lab No.: 6953383 Client No.: 3-08
Location: Northwest Corner Of 242d
3 Fibrous Glass
Lab No.: 6953383(L2)
Lab No.: 6953383(L3)
Lab No.: 6953384 Client No.: 3-09
Location: Doorway Of Room 365
Lab No.: 6953384(L2)
Laboratory Director
Approved By:
Date Analyzed:
1/16/2020Date Received:
Analyst:
Please refer to the Appendix of this report for further information regarding your analysis.
Signature:
Amy Latham
01/28/2020 Frank E. Ehrenfeld, III
9000 Commerce Parkway Suite B Mt. Laurel, New Jersey 08054
Telephone: 856-231-9449 Email: customerservice@iatl.com
CERTIFICATE OF ANALYSIS
Client: Terracon
611 Lunken Park Drive Cincinnati OH 45226
1/29/2020Report Date:
Report No.: 607942 - PLM Project: Fort Thomas VAMC Project No.: N1197176
PLM BULK SAMPLE ANALYSIS SUMMARY
Dated : 1/29/2020 1:29:01 Page 3 of 43
Lab No.: 6953384(L3)
Lab No.: 6953385 Client No.: 4-10
Analyst Observation: Tan/White Ceiling Tile Client Description: 2'x2' White Plain Ceiling Tiles
Location: Hallway Near Electrical Closet Facility:
40 Cellulose 40 Mineral Wool
Lab No.: 6953386 Client No.: 4-11
Location: Hallway Outside Room 244
Lab No.: 6953387 Client No.: 4-12
Location: Hallway Outside Room 232
Lab No.: 6953388 Client No.: 5-13
Analyst Observation: Grey Mastic Client Description: Grey Duct Mastic
Location: Hallway Outside Room 200
Lab No.: 6953389 Client No.: 5-14
Location: Hallway Outside Room 329
Laboratory Director
Approved By:
Date Analyzed:
1/16/2020Date Received:
Analyst:
Please refer to the Appendix of this report for further information regarding your analysis.
Signature:
Amy Latham
01/28/2020 Frank E. Ehrenfeld, III
9000 Commerce Parkway Suite B Mt. Laurel, New Jersey 08054
Telephone: 856-231-9449 Email: customerservice@iatl.com
CERTIFICATE OF ANALYSIS
Client: Terracon
611 Lunken Park Drive Cincinnati OH 45226
1/29/2020Report Date:
Report No.: 607942 - PLM Project: Fort Thomas VAMC Project No.: N1197176
PLM BULK SAMPLE ANALYSIS SUMMARY
Dated : 1/29/2020 1:29:01 Page 4 of 43
Lab No.: 6953390 Client No.: 5-15
Location: Hallway Outside Room 129
Laboratory Director
Approved By:
Date Analyzed:
1/16/2020Date Received:
Analyst:
Please refer to the Appendix of this report for further information regarding your analysis.
Signature:
Amy Latham
01/28/2020 Frank E. Ehrenfeld, III
9000 Commerce Parkway Suite B Mt. Laurel, New Jersey 08054
Telephone: 856-231-9449 Email: customerservice@iatl.com
CERTIFICATE OF ANALYSIS
Client: Terracon
611 Lunken Park Drive Cincinnati OH 45226
1/29/2020Report Date:
Report No.: 607942 - PLM Project: Fort Thomas VAMC Project No.: N1197176
PLM BULK SAMPLE ANALYSIS SUMMARY
Dated : 1/29/2020 1:29:01 Page 5 of 43
Lab No.: 6953391 Client No.: 6-16
Analyst Observation: White Sealant Client Description: White Encapsulant
Lab No.: 6953391(L2) Client No.: 6-16
Analyst Observation: Yellow Insulation
95 Fibrous Glass
Lab No.: 6953392 Client No.: 6-17
Location: Hallway Near Room 307a
Lab No.: 6953392(L2) Client No.: 6-17
Location: Hallway Near Room 307a
Lab No.: 6953393 Client No.: 6-18
Location: Hallway Outside Room 029
Lab No.: 6953393(L2) Client No.: 6-18
Laboratory Director
Approved By:
Date Analyzed:
1/16/2020Date Received:
Analyst:
Please refer to the Appendix of this report for further information regarding your analysis.
Signature:
Christopher Riffe
01/28/2020 Frank E. Ehrenfeld, III
9000 Commerce Parkway Suite B Mt. Laurel, New Jersey 08054
Telephone: 856-231-9449 Email: customerservice@iatl.com
CERTIFICATE OF ANALYSIS
Client: Terracon
611 Lunken Park Drive Cincinnati OH 45226
1/29/2020Report Date:
Report No.: 607942 - PLM Project: Fort Thomas VAMC Project No.: N1197176
PLM BULK SAMPLE ANALYSIS SUMMARY
Dated : 1/29/2020 1:29:01 Page 6 of 43
Lab No.: 6953394 Client No.: 7-19
Client Description: 2'x2' Ceiling Tile With Small Fissures
Location: Outside Offices 371
50 Cellulose 30 Mineral Wool
Lab No.: 6953395 Client No.: 7-20
Location: Hallway Outside Room 307
Lab No.: 6953396 Client No.: 7-21
Location: Hallway Outside Room 336
Lab No.: 6953397 Client No.: 8-22
Client Description: 2'x2 Ceiling Tile With Large Fissures
Location: Hallway Outside Room 113
Lab No.: 6953398 Client No.: 8-23
Location: Hallway Outside Room 102
Lab No.: 6953399 Client No.: 8-24
Location: Hallway Outside Room 031
Laboratory Director
Approved By:
Date Analyzed:
1/16/2020Date Received:
Analyst:
Please refer to the Appendix of this report for further information regarding your analysis.
Signature:
Christopher Riffe
01/28/2020 Frank E. Ehrenfeld, III
9000 Commerce Parkway Suite B Mt. Laurel, New Jersey 08054
Telephone: 856-231-9449 Email: customerservice@iatl.com
CERTIFICATE OF ANALYSIS
Client: Terracon
611 Lunken Park Drive Cincinnati OH 45226
1/29/2020Report Date:
Report No.: 607942 - PLM Project: Fort Thomas VAMC Project No.: N1197176
PLM BULK SAMPLE ANALYSIS SUMMARY
Dated : 1/29/2020 1:29:01 Page 7 of 43
Lab No.: 6953400 Client No.: 9-25
Location: Hallway Outside Room 123
Lab No.: 6953401 Client No.: 9-26
Location: Hallway Outside Room 023
Lab No.: 6953402 Client No.: 9-27
Lab No.: 6953403 Client No.: 10-28
Analyst Observation: Tan/White Ceramic Client Description: 1"x1" Red And White Ceramic Floor Tile With Mastic And Grout
Location: Room 108- Doorway To Shower Area Facility:
Lab No.: 6953403(L2)
Analyst Observation: Tan Mastic / Paper
Facility:
Lab No.: 6953403(L3)
Analyst Observation: Dk Grey Grout
Facility:
Laboratory Director
Approved By:
Date Analyzed:
1/16/2020Date Received:
Analyst:
Please refer to the Appendix of this report for further information regarding your analysis.
Signature:
Christopher Riffe
01/28/2020 Frank E. Ehrenfeld, III
9000 Commerce Parkway Suite B Mt. Laurel, New Jersey 08054
Telephone: 856-231-9449 Email: customerservice@iatl.com
CERTIFICATE OF ANALYSIS
Client: Terracon
611 Lunken Park Drive Cincinnati OH 45226
1/29/2020Report Date:
Report No.: 607942 - PLM Project: Fort Thomas VAMC Project No.: N1197176
PLM BULK SAMPLE ANALYSIS SUMMARY
Dated : 1/29/2020 1:29:01 Page 8 of 43
Lab No.: 6953404 Client No.: 10-29
Location: Room 108- Main Doorway To Bathroom Facility:
Lab No.: 6953404(L2)
Facility:
Lab No.: 6953404(L3)
Facility:
Lab No.: 6953405 Client No.: 10-30
Location: Room 156- Main Doorway To
Facility:
Lab No.: 6953405(L2)
Facility:
Lab No.: 6953405(L3)
Facility:
Laboratory Director
Approved By:
Date Analyzed:
1/16/2020Date Received:
Analyst:
Please refer to the Appendix of this report for further information regarding your analysis.
Signature:
Christopher Riffe
01/28/2020 Frank E. Ehrenfeld, III
9000 Commerce Parkway Suite B Mt. Laurel, New Jersey 08054
Telephone: 856-231-9449 Email: customerservice@iatl.com
CERTIFICATE OF ANALYSIS
Client: Terracon
611 Lunken Park Drive Cincinnati OH 45226
1/29/2020Report Date:
Report No.: 607942 - PLM Project: Fort Thomas VAMC Project No.: N1197176
PLM BULK SAMPLE ANALYSIS SUMMARY
Dated : 1/29/2020 1:29:02 Page 9 of 43
Lab No.: 6953406 Client No.: 11-31
Client Description: 4"x4" Tan Wall Tile With Yellow Mastic And Grout
Location: Room 108- Northeast Corner Of Bathroom Area Facility:
Lab No.: 6953406(L2) Client No.: 11-31
Facility:
Lab No.: 6953407 Client No.: 11-32
Facility:
Lab No.: 6953407(L2) Client No.: 11-32
Facility:
Lab No.: 6953408 Client No.: 11-33
Location: Room 156- Northwest Corner Of Room Facility:
Lab No.: 6953408(L2) Client No.: 11-33
Room Facility:
Laboratory Director
Approved By:
Date Analyzed:
1/16/2020Date Received:
Analyst:
Please refer to the Appendix of this report for further information regarding your analysis.
Signature:
Christopher Riffe
01/28/2020 Frank E. Ehrenfeld, III
9000 Commerce Parkway Suite B Mt. Laurel, New Jersey 08054
Telephone: 856-231-9449 Email: customerservice@iatl.com
CERTIFICATE OF ANALYSIS
Client: Terracon
611 Lunken Park Drive Cincinnati OH 45226
1/29/2020Report Date:
Report No.: 607942 - PLM Project: Fort Thomas VAMC Project No.: N1197176
PLM BULK SAMPLE ANALYSIS SUMMARY
Dated : 1/29/2020 1:29:02 Page 10 of 43
Lab No.: 6953409 Client No.: 12-34
Location: Room 108- Middle Of Room
Lab No.: 6953410 Client No.: 12-35
Location: Room 156- Middle Of Room
Lab No.: 6953411 Client No.: 12-36
Location: Room 156- Northwest Corner
Lab No.: 6953412 Client No.: 13-37
Analyst Observation: White/Tan Drywall
Facility:
11 Cellulose
Lab No.: 6953413 Client No.: 13-38
Shower Area Facility:
Lab No.: 6953413(L2)
Facility:
Laboratory Director
Approved By:
Date Analyzed:
1/16/2020Date Received:
Analyst:
Please refer to the Appendix of this report for further information regarding your analysis.
Signature:
Christopher Riffe
01/28/2020 Frank E. Ehrenfeld, III
9000 Commerce Parkway Suite B Mt. Laurel, New Jersey 08054
Telephone: 856-231-9449 Email: customerservice@iatl.com
CERTIFICATE OF ANALYSIS
Client: Terracon
611 Lunken Park Drive Cincinnati OH 45226
1/29/2020Report Date:
Report No.: 607942 - PLM Project: Fort Thomas VAMC Project No.: N1197176
PLM BULK SAMPLE ANALYSIS SUMMARY
Dated : 1/29/2020 1:29:02 Page 11 of 43
Lab No.: 6953413(L3)
Facility:
Lab No.: 6953414 Client No.: 13-39
Center Dividing Wall Facility:
Lab No.: 6953414(L2)
Facility:
Lab No.: 6953414(L3)
Facility:
Lab No.: 6953415 Client No.: 14-40
Analyst Observation: White/Tan Ceiling Tile Client Description: 2'x2' Drywall Ceiling Tiles
Location: Room 108- Northwest Corner
2 Fibrous Glass
Lab No.: 6953416 Client No.: 14-41
Location: Room 156- Southeast Corner
Laboratory Director
Approved By:
Date Analyzed:
1/16/2020Date Received:
Analyst:
Please refer to the Appendix of this report for further information regarding your analysis.
Signature:
Christopher Riffe
01/28/2020 Frank E. Ehrenfeld, III
9000 Commerce Parkway Suite B Mt. Laurel, New Jersey 08054
Telephone: 856-231-9449 Email: customerservice@iatl.com
CERTIFICATE OF ANALYSIS
Client: Terracon
611 Lunken Park Drive Cincinnati OH 45226
1/29/2020Report Date:
Report No.: 607942 - PLM Project: Fort Thomas VAMC Project No.: N1197176
PLM BULK SAMPLE ANALYSIS SUMMARY
Dated : 1/29/2020 1:29:02 Page 12 of 43
Lab No.: 6953417 Client No.: 14-42
Location: Room 156- Southwest Corner
Lab No.: 6953418 Client No.: 15-43
Location: Room 108- Middle Of Shower
Facility:
Lab No.: 6953418(L2)
Analyst Observation: Clear Mastic
Facility:
Lab No.: 6953418(L3)
Facility:
Lab No.: 6953418(L4)
Analyst Observation: Silver/White/Tan Wrap / Mastic
Facility:
30 Fibrous Glass
Laboratory Director
Approved By:
Date Analyzed:
1/16/2020Date Received:
Analyst:
Please refer to the Appendix of this report for further information regarding your analysis.
Signature:
Christopher Riffe
01/28/2020 Frank E. Ehrenfeld, III
9000 Commerce Parkway Suite B Mt. Laurel, New Jersey 08054
Telephone: 856-231-9449 Email: customerservice@iatl.com
CERTIFICATE OF ANALYSIS
Client: Terracon
611 Lunken Park Drive Cincinnati OH 45226
1/29/2020Report Date:
Report No.: 607942 - PLM Project: Fort Thomas VAMC Project No.: N1197176
PLM BULK SAMPLE ANALYSIS SUMMARY
Dated : 1/29/2020 1:29:02 Page 13 of 43
Lab No.: 6953418(L5)
Facility:
Lab No.: 6953418(L6)
Facility:
Lab No.: 6953419 Client No.: 15-44
Facility:
Lab No.: 6953419(L2)
Facility:
Lab No.: 6953419(L3)
Facility:
Laboratory Director
Approved By:
Date Analyzed:
1/16/2020Date Received:
Analyst:
Please refer to the Appendix of this report for further information regarding your analysis.
Signature:
Christopher Riffe
01/28/2020 Frank E. Ehrenfeld, III
9000 Commerce Parkway Suite B Mt. Laurel, New Jersey 08054
Telephone: 856-231-9449 Email: customerservice@iatl.com
CERTIFICATE OF ANALYSIS
Client: Terracon
611 Lunken Park Drive Cincinnati OH 45226
1/29/2020Report Date:
Report No.: 607942 - PLM Project: Fort Thomas VAMC Project No.: N1197176
PLM BULK SAMPLE ANALYSIS SUMMARY
Dated : 1/29/2020 1:29:02 Page 14 of 43
Lab No.: 6953419(L4)
Facility:
Lab No.: 6953420 Client No.: 15-45
Location: Room 156- Middle Of Bathroom
Facility:
Lab No.: 6953420(L2) Client No.: 15-45
Location: Room 156- Middle Of Bathroom
Facility:
Lab No.: 6953421 Client No.: 16-46
Analyst Observation: Lt Grey Insulation Client Description: Pipes Insulation And Hard Fittings
Location: North End Of Center Divider Wall In Room 156 Facility:
Lab No.: 6953421(L2) Client No.: 16-46
Analyst Observation: White Wrap
Facility:
95 Cellulose
Lab No.: 6953422 Client No.: 16-47
Facility:
Laboratory Director
Approved By:
Date Analyzed:
1/16/2020Date Received:
Analyst:
Please refer to the Appendix of this report for further information regarding your analysis.
Signature:
Christopher Riffe
01/28/2020 Frank E. Ehrenfeld, III
9000 Commerce Parkway Suite B Mt. Laurel, New Jersey 08054
Telephone: 856-231-9449 Email: customerservice@iatl.com
CERTIFICATE OF ANALYSIS
Client: Terracon
611 Lunken Park Drive Cincinnati OH 45226
1/29/2020Report Date:
Report No.: 607942 - PLM Project: Fort Thomas VAMC Project No.: N1197176
PLM BULK SAMPLE ANALYSIS SUMMARY
Dated : 1/29/2020 1:29:02 Page 15 of 43
Lab No.: 6953422(L2) Client No.: 16-47
Facility:
Lab No.: 6953423 Client No.: 16-48
Facility:
Lab No.: 6953423(L2) Client No.: 16-48
Facility:
Lab No.: 6953424 Client No.: 17-49
Location: Room 108- Middle North Wall
20 Fibrous Glass
Lab No.: 6953424(L2) Client No.: 17-49
Lab No.: 6953425 Client No.: 17-50
Laboratory Director
Approved By:
Date Analyzed:
1/16/2020Date Received:
Analyst:
Please refer to the Appendix of this report for further information regarding your analysis.
Signature:
Christopher Riffe
01/28/2020 Frank E. Ehrenfeld, III
9000 Commerce Parkway Suite B Mt. Laurel, New Jersey 08054
Telephone: 856-231-9449 Email: customerservice@iatl.com
CERTIFICATE OF ANALYSIS
Client: Terracon
611 Lunken Park Drive Cincinnati OH 45226
1/29/2020Report Date:
Report No.: 607942 - PLM Project: Fort Thomas VAMC Project No.: N1197176
PLM BULK SAMPLE ANALYSIS SUMMARY
Dated : 1/29/2020 1:29:02 Page 16 of 43
Lab No.: 6953425(L2) Client No.: 17-50
Lab No.: 6953426 Client No.: 17-51
Location: Room 156- Northeast Corner
Lab No.: 6953426(L2) Client No.: 17-51
Location: Room 156- Northeast Corner
Lab No.: 6953427 Client No.: 18-52
Analyst Observation: Lt Tan Plaster Client Description: Plaster Walls And Ceilings
Location: Middle North Wall
Lab No.: 6953428 Client No.: 18-53
Location: Middle North Wall
Lab No.: 6953429 Client No.: 18-54
Location: Northeast Corner
Laboratory Director
Approved By:
Date Analyzed:
1/16/2020Date Received:
Analyst:
Please refer to the Appendix of this report for further information regarding your analysis.
Signature:
Christopher Riffe
01/28/2020 Frank E. Ehrenfeld, III
9000 Commerce Parkway Suite B Mt. Laurel, New Jersey 08054
Telephone: 856-231-9449 Email: customerservice@iatl.com
CERTIFICATE OF ANALYSIS
Client: Terracon
611 Lunken Park Drive Cincinnati OH 45226
1/29/2020Report Date:
Report No.: 607942 - PLM Project: Fort Thomas VAMC Project No.: N1197176
PLM BULK SAMPLE ANALYSIS SUMMARY
Dated : 1/29/2020 1:29:02 Page 17 of 43
Lab No.: 6953430 Client No.: 19-55
Analyst Observation: White Covering Material Client Description: Fiberglass Reinforced Plastic Board With White Mastic
Location: Doorway Of Cooler Room 007
40 Fibrous Glass
Lab No.: 6953430(L2) Client No.: 19-55
Analyst Observation: White Mastic
Location: Doorway Of Cooler Room 007
Lab No.: 6953431 Client No.: 19-56
Location: Doorway Of Cooler Room 010
Lab No.: 6953431(L2) Client No.: 19-56
Location: Doorway Of Cooler Room 010
Lab No.: 6953432 Client No.: 19-57
Location: Doorway Of Cooler Room 010A
Lab No.: 6953432(L2) Client No.: 19-57
Location: Doorway Of Cooler Room 010A
Laboratory Director
Approved By:
Date Analyzed:
1/16/2020Date Received:
Analyst:
Please refer to the Appendix of this report for further information regarding your analysis.
Signature:
Christopher Riffe
01/28/2020 Frank E. Ehrenfeld, III
9000 Commerce Parkway Suite B Mt. Laurel, New Jersey 08054
Telephone: 856-231-9449 Email: customerservice@iatl.com
CERTIFICATE OF ANALYSIS
Client: Terracon
611 Lunken Park Drive Cincinnati OH 45226
1/29/2020Report Date:
Report No.: 607942 - PLM Project: Fort Thomas VAMC Project No.: N1197176
PLM BULK SAMPLE ANALYSIS SUMMARY
Dated : 1/29/2020 1:29:02 Page 18 of 43
Lab No.: 6953433 Client No.: 20-58
Analyst Observation: Red Brick Client Description: 6"x6" Red Ceramic Floor Tile With Mortar And Grout
Location: Doorway Of Cooler 006
Lab No.: 6953433(L2) Client No.: 20-58
Analyst Observation: Grey Mortar
Lab No.: 6953434 Client No.: 20-59
Lab No.: 6953434(L2) Client No.: 20-59
Lab No.: 6953435 Client No.: 20-60
Location: Doorway Of Cooler 010
Lab No.: 6953435(L2) Client No.: 20-60
Location: Doorway Of Cooler 010
Laboratory Director
Approved By:
Date Analyzed:
1/16/2020Date Received:
Analyst:
Please refer to the Appendix of this report for further information regarding your analysis.
Signature:
Christopher Riffe
01/28/2020 Frank E. Ehrenfeld, III
9000 Commerce Parkway Suite B Mt. Laurel, New Jersey 08054
Telephone: 856-231-9449 Email: customerservice@iatl.com
CERTIFICATE OF ANALYSIS
Client: Terracon
611 Lunken Park Drive Cincinnati OH 45226
1/29/2020Report Date:
Report No.: 607942 - PLM Project: Fort Thomas VAMC Project No.: N1197176
PLM BULK SAMPLE ANALYSIS SUMMARY
Dated : 1/29/2020 1:29:02 Page 19 of 43
Lab No.: 6953436 Client No.: 21-61
Analyst Observation: Blue/White Ceramic Client Description: Multi-Sized (1"x1" and 1'x2") Blue Ceramic Floor Tile With Mastic And Grout
Location: Doorway
Lab No.: 6953436(L2) Client No.: 21-61
Analyst Observation: Grey Grout
Lab No.: 6953437 Client No.: 21-62
Lab No.: 6953437(L2) Client No.: 21-62
Lab No.: 6953438 Client No.: 21-63
Lab No.: 6953438(L2) Client No.: 21-63
Laboratory Director
Approved By:
Date Analyzed:
1/16/2020Date Received:
Analyst:
Please refer to the Appendix of this report for further information regarding your analysis.
Signature:
Christopher Riffe
01/28/2020 Frank E. Ehrenfeld, III
9000 Commerce Parkway Suite B Mt. Laurel, New Jersey 08054
Telephone: 856-231-9449 Email: customerservice@iatl.com
CERTIFICATE OF ANALYSIS
Client: Terracon
611 Lunken Park Drive Cincinnati OH 45226
1/29/2020Report Date:
Report No.: 607942 - PLM Project: Fort Thomas VAMC Project No.: N1197176
PLM BULK SAMPLE ANALYSIS SUMMARY
Dated : 1/29/2020 1:29:02 Page 20 of 43
Lab No.: 6953439 Client No.: 22-64
Client Description: 4"x4" Blue Wall Tile With Mastic And Grout
Location: Southwest Corner
Lab No.: 6953439(L2)
Analyst Observation: Lt Tan Mastic
Lab No.: 6953439(L3)
Lab No.: 6953439(L4)
Analyst Observation: Off-White Cementitious
Lab No.: 6953440 Client No.: 22-65
Lab No.: 6953440(L2)
Laboratory Director
Approved By:
Date Analyzed:
1/16/2020Date Received:
Analyst:
Please refer to the Appendix of this report for further information regarding your analysis.
Signature:
Christopher Riffe
01/28/2020 Frank E. Ehrenfeld, III
9000 Commerce Parkway Suite B Mt. Laurel, New Jersey 08054
Telephone: 856-231-9449 Email: customerservice@iatl.com
CERTIFICATE OF ANALYSIS
Client: Terracon
611 Lunken Park Drive Cincinnati OH 45226
1/29/2020Report Date:
Report No.: 607942 - PLM Project: Fort Thomas VAMC Project No.: N1197176
PLM BULK SAMPLE ANALYSIS SUMMARY
Dated : 1/29/2020 1:29:02 Page 21 of 43
Lab No.: 6953440(L3)
Lab No.: 6953440(L4)
Lab No.: 6953441 Client No.: 22-66
Lab No.: 6953441(L2)
Lab No.: 6953441(L3)
Lab No.: 6953441(L4)
Laboratory Director
Approved By:
Date Analyzed:
1/16/2020Date Received:
Analyst:
Please refer to the Appendix of this report for further information regarding your analysis.