100_ CD Drawings_Combined -07202020.pdf
PDF 8 MB Posted
- Solicitation number
- 36C25020B0059
About this file
This notice provides information about a forthcoming solicitation for Correct FCA Deficiencies - FTD Interior Deficiencies project number 539-20-211. The project scope involves interior repairs and modifications to several group restrooms, locker rooms, and shower rooms; replacement of coolers and freezer; and replacement of public address system. The solicitation is expected to be released on or about August 10, 2020 on beta.sam.gov.
The opportunity is designated as a 100% set-aside for a small business, specifically a Service-Disabled Veteran Owned Small Business. The NAICS code is 238220 with a business size standard of $16.5 million. The duration of the project may not exceed 180 calendar days from notice to proceed. Bonds will be required in the form of offer, payment, and performance. The project magnitude is estimated between $500,000 to $1 million. Offerors must be able to provide safety, environmental, or OSHA violations history and experience modification rate prior to award.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| MH111.pdf | ||
| ED000A - BASEMENT ELECTRICAL DEMO PLAN- AREA A.pdf | ||
| AE111.pdf | ||
| FX101 - FIRE PROTECTION BASEMENT PLANS.pdf | ||
| Asbestos Survey Report.pdf | ||
| 114121 Walk-In Coolers and Freezers.pdf | ||
| AD112.pdf | ||
| Site Visit Sign In Sheet.pdf | ||
| EP000A - BASEMENT ELECTRICAL NEW WORK - AREA A.pdf | ||
| 2nd Sign in Sheet.pdf | ||
| 230511 Common Work Results for HVAC.pdf | ||
| MD101.pdf | ||
| AE101.pdf | ||
| 36C25020B0059 0002.docx | DOCX document | |
| AD111.pdf | ||
| 36C25020B0059 0001.docx | DOCX document | |
| Corbin Russwin Locksets Sole Source Justification - Redacted.pdf | ||
| S02 RFI Form.docx | DOCX document | |
| S02 Contractor EMR Certification Form.docx | DOCX document | |
| 539-20-211_Specifications (Combined).pdf | ||
| 36C25020B0059.docx | DOCX document | |
| Wage Determination.pdf |
Show all 22
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
1. SEE GENERAL PROJECT NOTES FOR NEW WORK FOR ADDITIONAL REQUIREMENTS FOR WORK WITHIN THE EXISTING FACILITY.
2. THE GENERAL CONTRACTOR SHALL VERIFY ALL EXISTING DIMENSIONS AND FIELD CONDITIONS PRIOR TO DEMOLITION AND CONSTRUCTION. IF PROVIDED, THE GENERAL CONTRACTOR SHALL CAREFULLY EXAMINE EXISTING BUILDING DOCUMENTS. THE CONTRACTOR SHALL BRING ANY
DISCREPANCIES TO THE IMMEDIATE ATTENTION OF THE ARCHITECT.
3. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR THE PROTECTION OF EXISTING ITEMS TO REMAIN DURING DEMOLITION AND CONSTRUCTION.
4. MAINTAIN EXIT EGRESS PATHS TO EXISTING EXIT DOORS DURING CONSTRUCTION.
5. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR THE PROTECTION OF ALL CONSTRUCTION ROUTES BEYOND THE AREAS OF WORK AND THE
ROUTES MUST BE RETURNED TO THEIR ORIGINAL CONDITION AT THE END OF THE PROJECT.
6. MAINTAIN THE BUILDING IN A WEATHER TIGHT CONDITION AT ALL TIMES.
7. ALL DEMOLITION AND CONSTRUCTION ACTIVITIES SHALL BE COORDINATED WITH THE COR TO MINIMIZE DISRUPTIONS OF NORMAL FUNCTIONS OF THE
VAMC'S OCCUPIED AREAS.
8. IF CONSTRUCTION NOISE IS ANTICIPATED, SUBMIT A WRITTEN REQUEST TO THE COR FOR THE SCHEDULED TIME OF THE CONSTRUCTION ACTIVITIES.
NO WORK SHALL BE DONE WITHOUT THE WRITTEN APPROVAL OF THE COR. THE COR RESERVES THE RIGHT TO DISCONTINUE NOISY CONSTRUCTION AT ANY TIME. NO RADIOS SHALL BE PERMITTED AT ANY TIME IN WORK AREAS ADJACENT TO OCCUPIED SPACES.
9. ALL EXISTING SERVICES AND UTILITIES SHALL BE MAINTAINED TO ADJACENT DEPARTMENTS OR AREAS THAT ARE IN OPERATION AND SERVED BY THEM. COORDINATE ALL DISRUPTIONS OR DISCONTINUATIONS OF UTILITIES AND SERVICES WITH THE COR. NO SHUT DOWN OF EXISTING SERVICES IS ALLOWED TO OCCUR UNTIL RECEIVING THE COR'S WRITTEN APPROVAL OF THE SHUT DOWN SCHEDULE. PROVIDE TEMPORARY SERVICES AND/OR
UTILITIES DURING INTERRUPTIONS AS REQUIRED AND APPROVED BY THE COR.
10. THE GENERAL CONTRACTOR SHALL TAKE ALL NECESSARY PRECAUTIONS TO PREVENT DAMAGE TO THE VA'S OCCUPIED AREAS ADJACENT TO NEW CONSTRUCTION OR OCCUPIED AREAS WHERE VARIOUS SYSTEM CONNECTIONS OR EXTENSIONS ARE REQUIRED. IN THESE AREAS, THE GENERAL CONTRACTOR IS RESPONSIBLE FOR DAMAGE CAUSED BY LACK OF SUFFICIENT PROTECTION FROM THE WEATHER AND FROM THE RESULTS OF ALL
CONSTRUCTION ACTIVITY INCLUDING BUT NOT LIMITED TO DUST AND WATER.
11. THE GENERAL CONTRACTOR SHALL RECEIVE WRITTEN APPROVAL FROM THE COR BEFORE USING OPEN FLAMES, WELDING RODS AND TORCHES. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR ALL MEANS AND METHODS TO PROHIBIT THE MIGRATION OF SMOKE AND OTHER PRODUCTS OF COMBUSTION INTO OCCUPIED AREAS OF THE EXISTING BUILDING AND FOR OBTAINING ALL REQUIRED PERMITS RELATED TO HOT WORK.
12. IT IS THE GENERAL CONTRACTORS RESPONSIBILITY TO PATCH ALL SPRAY-ON FIRE PROTECTION AT REMOVALS, AT ANY EXISTING LOCATIONS WHICH ARE VOID OF PROTECTION WITHIN THE AREA OF WORK AND AT NEW CONSTRUCTION WHICH DISTURBS EXISTING FIRE PROTECTION. FIREPROOFING
MUST BE CONTINUOUS AND UNOBSTRUCTED.
13. DO NOT OVERLOAD THE EXISTING BUILDING STRUCTURE. MAINTAIN THE STRUCTURAL INTEGRITY OF ALL STRUCTURAL FRAMING MEMBERS AND
SYSTEMS AT ALL TIMES.
14. ALL DEMOLISHED MATERIAL, EXCEPT MATERIAL THAT IS LISTED OR MARKED BY THE ARCHITECT OR THE COR FOR RETENTION, SHALL BECOME THE PROPERTY OF THE CONTRACTOR AND IT SHALL BE DISPOSED OF. NO DEBRIS RESULTING FROM WORK SHALL BE LEFT IN THE CONSTRUCTION ROUTES
BEYOND THE AREAS OF WORK.
15. REMOVAL OF A PARTICULAR ITEM IS TO INCLUDE ALL RELATED ITEMS, SUCH AS REMOVAL OF WALLS WOULD INCLUDE ASSOCIATED DOORS, HARDWARE, ELECTRICAL, PLUMBING, MECHANICAL, ETC. REFER TO DEMOLITION DRAWINGS FOR MORE INFORMATION. FOR ALL REMOVALS, THE GENERAL CONTRACTOR SHALL COORDINATE WITH ALL OTHER DISCIPLINES INCLUDING BUT NOT LIMITED TO MECHANICAL, ELECTRICAL AND
PLUMBING.
16. WHERE CEILINGS ARE SHOWN TO BE REMOVED, ALL UNUSED SUSPENDED EQUIPMENT, WIRES, ANGLES, ETC. SHALL BE REMOVED. SEE DEMOLITION DRAWINGS FOR ADDITIONAL INFORMATION. EXISTING LIGHTS MAY BE MAINTAINED AS TEMPORARY CONSTRUCTION LIGHTING.
17. THE CONTRACTOR SHALL PROVIDE TEMPORARY SUPPORT FOR ITEMS NOT DEMOLISHED OR REMOVED AS REQUIRED UNTIL PERMANENT SUPPORT IS
PROVIDED IN THE FINAL CONSTRUCTION.
18. ALL OPENINGS IN EXISTING WALLS, CEILINGS AND FLOORS, WHICH ARE THE RESULT OF REMOVALS AND OTHER NEW CONSTRUCTION ACTIVITY, SHALL BE PATCHED WITH NEW MATERIALS THAT MATCH THE EXISTING MATERIALS. IF THE PATCH IS TO BE MADE IN FIRE RATED CONSTRUCTION, THE PATCH MUST ACHIEVE THE REQUIRED FIRE RATING. THE PATCH SHALL BE FINISHED TO A LIKE NEW CONDITION TO MATCH THE EXISTING FINISH.
19. ALL EXISTING OPENINGS IN CEILINGS, FLOORS AND WALLS DISCOVERED IN THE EXISTING STRUCTURE SHALL BE PATCHED WITH NEW MATERIALS THAT MATCH THE EXISTING MATERIALS. IF THE PATCH IS TO BE MADE IN FIRE RATED CONSTRUCTION, THE PATCH MUST ACHIEVE THE REQUIRED FIRE RATING. THE PATCH SHALL BE FINISHED TO A LIKE NEW CONDITION TO MATCH THE EXISTING FINISH.
20. WHERE EXISTING SURFACES ARE TO BE REFINISHED OR ARE TO SERVE AS SUBSTRATE FOR THE ATTACHMENT OR APPLICATION OF NEW MATERIALS OR CONSTRUCTION, PREPARE OR ALTER THE EXISTING SURFACES AS NECESSARY TO PROPERLY ACCOMMODATE THE NEW MATERIALS.
21. FIELD VERIFY SIZES AND DIMENSIONS OF ALL EXISTING UTILITIES THAT IMPACT THE NEW WORK. DETERMINE THE SIZE AND LOCATION THE PENETRATIONS FROM THE EXISTING UTILITIES WITHIN THE NEW WORK. SEAL TIGHT TO ALL PENETRATIONS AND CAULK.
22. PENETRATIONS THROUGH EXISTING FIRE RATED CONSTRUCTION MUST BE PROPERLY CLOSED AND FIRE SAFE'D TO ACHIEVE THE PROPER FIRE
RATING BY THE END OF CONSTRUCTION OPERATIONS FOR EACH DAY.
23. NEW HOLES IN EXISTING ELEVATED FLOOR AND ROOF STRUCTURES FOR NEW WORK MUST BE COORDINATED WITH THE EXISTING STRUCTURE SO
THAT CRITICAL STRUCTURAL MEMBERS ARE NOT DAMAGED.
24. UNLESS OTHERWISE NOTED, THE GENERAL CONTRACTOR IS RESPONSIBLE FOR VERIFYING ALL EXISTING SALVAGED STOCK BEFORE ORDERING NEW
MATERIAL.
25. ALL CONTRACTORS SHALL WEAR FACE COVERINGS OVER NOSE AND MOUTH WHILE ON THE PREMISES PER VA FACILITY POLICY. FACE COVERINGS
SHALL BE PROVIDED BY CONTRACTOR.
G E N E R A L N O T E S - E X I S T I N G F A C I L I T I E S
1. ALL WORK SHALL BE DONE IN ACCORDANCE WITH APPLICABLE LOCAL, STATE AND FEDERAL AUTHORITIES, CODES, RULES AND REGULATIONS.
2. THESE DOCUMENTS SHOW THE MINIMUM CONSTRUCTION REQUIREMENTS AND THE MINIMUM QUALITY OF WORK EXPECTED. MORE STRINGENT REQUIREMENTS STIPULATED WITHIN RELEVANT MANUFACTURER’S INSTALLATION INSTRUCTIONS WILL SUPERSEDE.
3. ANY UNFORESEEN OR UNCLEAR CONDITIONS SHALL BE REPORTED TO THE ARCHITECT PRIOR TO PROCEEDING WITH WORK.
4. ANY CONFLICTS WITHIN THE DRAWINGS, BETWEEN THE DRAWINGS AND THE SPECIFICATIONS, OR BETWEEN THE DRAWINGS AND THE ACTUAL CONDITIONS AT THE SITE, ARE TO BE BROUGHT TO THE IMMEDIATE ATTENTION OF THE ARCHITECT. THE CONTRACTOR SHALL NOT PROCEED WITH
WORK UNTIL WRITTEN CLARIFICATION FROM THE ARCHITECT IS RECEIVED.
5. UNLESS OTHERWISE NOTED, ALL MATERIALS AND EQUIPMENT ARE TO BE INSTALLED PER THE APPLICABLE PROVISIONS OF THESE DOCUMENTS AND
THE MANUFACTURER’S INSTRUCTIONS.
6. ALL MATERIALS USED ARE REQUIRED TO BE NEW UNLESS OTHERWISE NOTED AND/OR OF A QUALITY TO MEET OR EXCEED ALL APPLICABLE INDUSTRY STANDARDS. WHERE SPECIFIED PRODUCTS OR MANUFACTURERS ARE NOT NOTED, THE CONTRACTOR IS REQUIRED TO NOTIFY THE ARCHITECT TO
OBTAIN A MINIMUM STANDARD OF QUALITY.
7. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR ALL MEANS, METHODS AND TECHNIQUES FOR CONSTRUCTION.
8. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR JOB-SITE SAFETY INCLUDING BUT NOT LIMITED TO THE ADHERENCE TO OSHA REGULATIONS.
9. ALL ELECTRICAL AND MECHANICAL WORK SHALL BE PERFORMED BY PERSONNEL LICENSED IN THE STATE WHERE THIS PROJECT IS LOCATED.
10. REMOVE ALL DEBRIS PROPERLY FROM THE SITE. LOAD DEBRIS DIRECTLY ONTO TRUCKS OR INTO DUMPSTERS FOR REMOVAL. DISPOSE OF DEBRIS LEGALLY. DO NOT BURN DEBRIS ON THE SITE. DO NOT ALLOW DEBRIS TO ENTER SEWERS. DO NOT ALLOW PILED DEBRIS TO ENDANGER STRUCTURES, BLOCK EXISTS OR ROADWAYS. COMBUSTIBLE WASTE WHICH COULD CREATE A FIRE HAZARD SHALL NOT BE PERMITTED TO
ACCUMULATE IN OR AROUND THE CONSTRUCTION SITE.
11. COORDINATE ALL WORK WITH ALL OTHER DISCIPLINES, INCLUDING, BUT NOT LIMITED TO MECHANICAL, ELECTRICAL, PLUMBING & SITE DRAWINGS.
EXACT SIZE AND LOCATION OF ALL ROOF AND FLOOR OPENINGS SHOWN ON ARCHITECTURAL DRAWINGS SHALL BE VERIFIED WITH THE ASSOCIATED
SUB-CONTRACTORS PRIOR TO CONSTRUCTION.
12. DO NOT SCALE DRAWINGS. DIMENSIONS SHALL GOVERN. ALL PLAN DIMENSIONS ARE TAKEN TO FINISH FACE OF CONSTRUCTION.
13. LAYOUT AND VERIFY ALL PARTITION LOCATIONS PRIOR TO CONSTRUCTION FOR CLEARANCES AND DIMENSIONS. NOTIFY ARCHITECT OF ANY
DISCREPANCIES.
14. WITHIN ALL METAL STUD PARTITIONS, THE GENERAL CONTRACTOR IS TO PROVIDE BLOCKING FOR ALL WALL MOUNTED EQUIPMENT AND ACCESSORIES INCLUDING BUT NOT LIMITED TO: MECHANICAL, ELECTRICAL AND PLUMBING DEVICES, FURNITURE, CASEWORK, MILLWORK AND ALL OTHER WALL MOUNTED ACCESSORIES AND ITEMS. THE LOCATIONS, MOUNTING HEIGHTS AND BLOCKING REQUIREMENTS SHOWN HEREON ARE GIVEN FOR INFORMATIONAL PURPOSES ONLY AND IT IS THE RESPONSIBILITY OF THE GENERAL CONTRACTOR TO VERIFY THIS INFORMATION WITH THE ASSOCIATED SUB-CONTRACTORS, MANUFACTURERS, OR EQUIPMENT SUPPLIERS. SEE TYPICAL BLOCKING DETAILS IN METAL STUD WALLS
INCLUDED IN THESE DOCUMENTS FOR BLOCKING AND ANCHORING REQUIREMENTS.
15. ALL CONCEALED WOOD SHALL BE FIRE RETARDANT TREATED.
16. THE GENERAL CONTRACTOR SHALL COORDINATE WITH ALL OTHER DISCIPLINES INCLUDING BUT NOT LIMITED TO MECHANICAL, ELECTRICAL AND PLUMBING, TO DETERMINE THE SIZE AND LOCATION OF ALL PENETRATIONS IN NEW CONSTRUCTION. COORDINATE AND PROVIDE ALL OPENINGS. SEAL
CONSTRUCTION TIGHT TO ALL PENETRATIONS AND CAULK.
17. ALL PENETRATIONS THROUGH FIRE RATED CONSTRUCTION MUST BE FIRE SAFE'D IN ACCORDANCE WITH THE SPECIFICATIONS.
18. PROVIDE CONTROL JOINTS IN GYPSUM WALLBOARD INTERIOR PARTITIONS AT 30 FEET ON CENTER MAXIMUM. WHERE POSSIBLE, LOCATE AT CORNERS ABOVE OPENINGS. VERIFY LOCATIONS WITH ARCHITECT. SEE THE ASSOCIATED TYPICAL DETAILS INCLUDED IN THESE DOCUMENTS.
19. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR COORDINATING ALL EQUIPMENT INSTALLATION AND VERIFYING ALL REQUIRED ROUGH OPENINGS, AND ROUGH-IN DIMENSIONS WITH THE EQUIPMENT MANUFACTURER, COR AND ARCHITECT PRIOR TO CONSTRUCTION.
G E N E R A L N O T E S - N E W W O R K
G E N E R A L P H A S I N G N O T E S
A. NO MORE THAN ONE COOLER SHALL BE INOPERABLE AT ANY TIME DURING CONSTRUCTION. DURING RENOVATION, CONTENTS FROM COOLERS WILL BE RELOCATED INTO EXISTING OR NEW COOLERS BY VA. CONTRACTOR SHALL NOTIFY VA C.O.R. THREE WEEKS PRIOR TO DEMOLITION OF EACH COOLER OR FREEZER IN ORDER TO ENSURE RELOCATION OF CONTENTS OCCURS PRIOR TO DEMOLITION. CONTRACTOR SHALL PROVIDE TEMPORARY REFRIGERATION FOR CONTENTS OF FREEZER DURING RENOVATION OF FREEZER 010A.
B. CONTRACTOR SHALL NOTIFY VA C.O.R. THREE WEEKS PRIOR TO INSTALLATION OF NEW COOLERS AND FREEZER IN ORDER TO COORDINATE
INSTALLATION OF DOMESTIC WATER PIPES ABOVE COOLERS (BY VA; NOT IN CONTRACT).
C. RESTROOMS ON FIRST FLOOR SHALL BE RENOVATED SEPARATELY. AT NO TIME WILL TWO PATIENT RESTROOMS BE INACCESSIBLE.
S U M M A R Y OF B I D A L T E R N A T E S
ALTERNATE #1: OMIT NEW PA SYSTEM. EXISTING PA SYSTEM TO REMAIN.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
100% CONSTRUCTION
DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
FFE INC
110 Boggs Lane, Suite 170
Springdale, OH 45246
513-522-0956
C U s e rs
\c ra ig \D o c u m e n ts \F t T h o m a s c ra ig .l ie g ib e l@ ff e
-s e rv .c o m
.r v t
/2
/2
:3
:1
P
M
GI000
COVER SHEET, SHEET INDEX CORRECT FCA DEFICIENCIES -
FTD INTERIOR DEFICIENCIES
FT THOMAS, KY 41075
539-20-211
BUILDING 64
05/01/20 PRQ PRQ
SHEET # SHEET NAME ISSUE DATE SD DD1 DD2 CD
GENERAL
GI000 COVER SHEET, SHEET INDEX 05/01/20 * * * *
GI001 LIFE SAFETY PLAN 05/01/20 * * * *
GI002 WALL TYPES AND NOTES 05/01/20 * * * *
ARCHITECTURAL
AD101 OVERALL DEMOLITION PLANS 05/01/20 * * * *
AD111 ENLARGED BASEMENT DEMOLITION PLAN 05/01/20 * * * *
AD112 ENLARGED FIRST FLOOR DEMOLITION PLANS 05/01/20 * * * *
AE101 OVERALL NEW WORK PLANS 05/01/20 * * * *
AE111 ENLARGED BASEMENT PLANS 05/01/20 * * * *
AE112 ENLARGED FIRST FLOOR PLANS 05/01/20 * * * *
AE141 REFLECTED CEILING PLANS 05/01/20 * * * *
AE601 ROOM FINISH SCHEDULE, DOOR SCHEDULE, AND
DETAILS
05/01/20 * * *
FIRE PROTECTION
FX101 FIRE PROTECTION BASEMENT PLANS 05/01/20 * * *
PLUMBING
P001 PLUMBING LEGEND AND ABBREVIATIONS 05/01/20 * * *
PD101 PLUMBING BASEMENT DEMOLITION PLANS 05/01/20 * * *
PD102 PLUMBING FIRST FLOOR DEMOLITION PLANS 05/01/20 * * *
PL101 PLUMBING BASEMENT NEW WORK PLANS 05/01/20 * * *
PL102 PLUMBING FIRST FLOOR NEW WORK PLANS 05/01/20 * * *
PL401 PLUMBING SECTIONS 05/01/20 * * *
PL501 PLUMBING DETAILS AND SCHEDULES 05/01/20 * * *
PL601 PLUMBING ISOMETRIC DIAGRAMS 05/01/20 * *
MECHANICAL
MI001 MECHANICAL SYMBOLS AND ABBREVIATIONS 05/01/20 * * * *
MD101 MECHANICAL DEMOLITION PLANS 05/01/20 * * * *
MH101 MECHANICAL NEW WORK PLANS 05/01/20 * * * *
MH111 ENLARGED MECHANICAL PLANS 05/01/20 * * *
MH501 HVAC CONTROLS AND DETAILS 05/01/20 * * *
MH601 MECHANICAL SCHEDULES 05/01/20 * * * *
ELECTRICAL
E001 ELECTRICAL LEGEND AND ABBREVIATIONS 05/01/20 * * *
E002 PANELBOARD SCHEDULES 05/01/20 * * *
E003 ELECTRICAL DETAILS 05/01/20 * * *
ED000A BASEMENT ELECTRICAL DEMO PLAN- AREA A 05/01/20 * * *
ED000B BASEMENT ELECTRICAL DEMO PLAN - AREA B 05/01/20 * * *
ED100A FIRST FLOOR ELECTRICAL DEMO PLAN - AREA A 05/01/20 * * *
ED100B FIRST FLOOR ELECTRICAL DEMO PLAN - AREA B 05/01/20 * * *
ED200A SECOND FLOOR ELECTRICAL DEMO PLAN - AREA A 05/01/20 * * *
ED200B SECOND FLOOR ELECTRICAL DEMO PLAN - AREA B 05/01/20 * * *
ED300A THIRD FLOOR ELECTRICAL DEMO PLAN - AREA A 05/01/20 * * *
ED300B THIRD FLOOR ELECTRICAL DEMO PLAN - AREA B 05/01/20 * * *
EP000A BASEMENT ELECTRICAL NEW WORK - AREA A 05/01/20 * * *
EP000B BASEMENT ELECTRICAL NEW WORK - AREA B 05/01/20 * * *
EP100A FIRST FLOOR ELECTRICAL NEW WORK - AREA A 05/01/20 * * *
EP100B FIRST FLOOR ELECTRICAL NEW WORK - AREA B 05/01/20 * * *
EP200A SECOND FLOOR ELECTRICAL NEW WORK - AREA A 05/01/20 * * *
EP200B SECOND FLOOR ELECTRICAL NEW WORK - AREA B 05/01/20 * * *
EP300A THIRD FLOOR ELECTRICAL NEW WORK - AREA A 05/01/20 * * *
EP300B THIRD FLOOR ELECTRICAL NEW WORK - AREA B 05/01/20 * * *
CINCINNATI VAMC
CORRECT FCA DEFICIENCIES
DEPARTMENT OF VETERANS AFFAIRS
1000 S FT THOMAS AVE,
FT. THOMAS, KENTUCKY 41075
FTD INTERIOR DEFICIENCIES
D R A W I N G I N D E X
CD 100% SUBMITTAL DATE 05/01/2020
C O D E N O T E S
CODE SUMMARY:
PROJECT CONSISTS OF INTERIOR REPAIR AND MINOR MODIFICATION TO SEVERAL GROUP RESTROOMS, LOCKER ROOMS, AND SHOWER ROOMS;
REPLACEMENT OF COOLERS AND FREEZER; AND REPLACEMENT OF PUBLIC ADDRESS SYSTEM.
APPLICABLE BUILDING CODES AND STANDARDS:
NFPA 101-2018 LIFE SAFETY CODE
NFPA 5000-2018 BUILDING CONSTRUCTION AND SAFETY STANDARD
ABAAS and VA SUPPLEMENT PG-18-13 "VA BARRIER FREE DESIGN STANDARD" REVISED NOVEMBER 1, 2017
NFPA 70, NATIONAL ELECTRIC CODE 2017 EDITION
NFPA 72, NATIONAL FIRE ALARM AND SIGNALING CODE 2019 EDITION
INTERNATIONAL BUILDING CODE 2018 EDITION
VA MASTER SPECIFICATION, TECHNICAL INFORMATION LIBRARY (TIL)
CONSTRUCTION TYPE:
TYPE II (222)
OCCUPANCY CLASSIFICATION (NFPA 101-2018 CHAPTER 6.1.5 AND 6.1.6):
AMBULATORY HEALTHCARE (BASEMENT), HEALTHCARE (1ST, 2ND, 3RD FLOORS)
BUILDING SERVICE AND FIRE PROTECTION EQUIPMENT (NFPA 101 CHAPTER 9):
BUILDING SHALL BE FULLY SPRINKLERED PER NFPA 13. EXISTING, COMPLIANT.
BUILDING REHABILITATION (NFPA 101-2018 CHAPTER 43):
43.3 REPAIRS.
WORK SHALL NOT MAKE THE BUILDING LESS CONFORMING TO CHAPTERS OF NFPA 101-2018, OR WITH ANY PREVIOUSLY APPROVED ALTERNATIVE
ARRANGEMENTS, THAN IT WAS BEFORE THE REPAIR WAS UNDERTAKEN.
43.5 MODIFICATIONS.
WORK MUST COMPLY WITH CHAPTERS OF NFPA 101-2018.
Revisions: Date:
100% Construction/BID Documents 05/01/2020 05/01/20 Exp: 12/31/2021
FE
FE
FE
FE
FE
FE
FE
FE
FE
FE
FE
FE
FE
FE
FEFE
FE
FE
SMOKE RESISTIVE HAZARDOUS ROOM ENCLOSURE
WALL: IF THE HAZARDOUS ROOM HAS A SUSPENDED CEILING CONSTRUCTED TO LIMIT
TRANSFER OF SMOKE, THE WALL HAS NO FIRE RESISTANCE RATING AND MAY
TERMINATE AT THE CEILING. IF THE ROOM DOES NOT HAVE SUSPENDED
CEILING, THE WALL HAS NO FIRE RESISTANCE RATING AND SHALL EXTEND TO
THE DECK ABOVE.
DUCTS: STEEL DUCT PENETRATIONS ARE NOT REQUIRED TO BE PROTECTED BY FIRE
DAMPERS OR SMOKE DAMPERS.
PENETRATIONS: SEALED WITH NON-FIRE-RATED MATERIAL TO BE RESISTIVE. USE OF LISTED
FIRESTOP MATERIALS IS NOT REQUIRED.
DOORS: EXISTING HAZARDOUS ROOMS:
1. NON-LABELED FRAME (NFPA 101 19.3.7.9)
2. 20 MINUTE OR SOLID WOOD CORE (NFPA 101 19.3.7.6) 1 3/4 THICK.
3. MAXIMUM 1296 SQ. IN. WINDOW (NFPA 101 19.3.6.3.17)
4. POSITIVE LATCHING NOT REQUIRED (NFPA 101 19.3.2.1.3)
5. SELF CLOSING OR AUTOMATIC CLOSING (NFPA 101 19.3.2.1.3)
6. MAXIMUM 1" UNDERCUT (NFPA 101 19.3.2.1.2)
7. MAXIMUM 1/8" GAP (NFPA 101 19.3.6.3.1)
8. MAXIMUM 48" PROTECTIVE PLATE (NFPA 101 19.3.2.1.2)
9. SWING IN ANY DIRECTION
10. SMOKE DOOR ASSEMBLIES SHALL BE TESTED AT LEAST ANNUALLY
(NFPA 105 5.2.1.1)
NON-RATED SMOKE ZONE PARTITION
FORMER DECOMMISSIONED SMOKE BARRIER RETAINED AS FIRE ALARM/SPRINKLER
ZONE. BUILDING OCCUPANTS PERMITTED TO DEFEND IN PLACE UNTIL DIRECTED BY
THE FIRE DEPARTMENT PER SECTION 16.7.4.3 OF NFPA 99-2018 EDITION AND PRIVATE
MODE AUDIBLE REQUIREMENTS OF SECTION 16.7.4.3 OR NFPA 72-2019 EDITION.
WALL: WALL EXTENDS FROM FLOOR TO SUSPENDED CEILING OR DECK ABOVE.
DUCTS: NO MINIMUM REQUIREMENTS.
PENETRATIONS: NO MINIMUM REQUIREMENTS FOR WALL PENETRATIONS ABOVE A SUSPENDED
CEILING. PENETRATIONS BELOW A SUSPENDED CEILING OR DECK SEALED
WITH NON-FIRE-RATED MATERIALS TO BE SMOKE RESISTIVE.
DOORS: NON-FIRE-RATED DOORS AND FRAMES SELF CLOSING OR AUTOMATIC CLOSING
IN AN EMERGENCY.
THIS APPLIES TO OCCUPANCY SEPARATION WALLS, HORIZONTAL EXITS, AND STAIRWELLS OF 4 OR MORE STORIES.
THIS COMBINATION WALL IS WHERE A PORTIONOF THE 2-HOUR RATED WALL IS ALSO PART OF THE SMOKE WALL.
WALL: WALL EXTENDS FROM FLOOR TO DECK ABOVE.
DUCTS: ALL DUCT PENETRATIONS ARE PROTECTED BY COMBINATION FIRE AND
SMOKE DAMPERS. SMOKE DAMPERS ARE NOT REQUIRED WHERE
ADJACENT SMOKE COMPARTMENTS ARE PROTECTED BY QUICK
RESPONSE SPRINKLERS THROUGHOUT EACH COMPARTMENT.
PENETRATIONS: ALL NEW PENETRATIONS ARE SEALED WITH LISTED FIRESTOP
MATERIALS FOR PROTECTING 2-HOUR WALL ASSEMBLIES. WALL
PENETRATIONS ARE REQUIRED TO BE FILLED ON BOTH SIDES OF THE
WALL. FLOOR PENETRATIONS ARE ONLY REQUIRED TO BE FILLED ON
THE TOP OF THE FLOOR.
DOORS: ALL DOORS REQUIRE THE FOLLOWING:
1. LABELED FRAMES (NFPA 80 4.2.1)
2. LABELED 1 1/2 HOUR DOOR (NFPA 80 4.3.1)
3. MAXIMUM 100 SQ. IN. WINDOW (NFPA 80 4.4.5)
4. POSITIVE LATCHING (NFPA 80 6.4.1.4)
5. SELF CLOSING OR AUTOMATIC CLOSING (NFPA 80 6.4.1)
6. COORDINATING DEVICES REQUIRED (NFPA 80 6.4.1.2.1)
7. MAXIMUM 1/8" GAP (NFPA 80 6.3.1.7.3)
8. MAXIMUM 3/4" UNDERCUT (NFPA 80 4.8.4.1)
9. MAXIMUM 16" PROTECTIVE PLATE (NFPA 80 6.4.5.1)
10. SWING IN PRIMARY DIRECTION OF TRAVEL (NFPA 101 18/19.2.2.2).
11. PERIODIC INSPECTION AND TESTING SHALL BE PERFORMED AT
LEAST ANNUALLY (NFPA 80 5.2.4.1)
2-HOUR FIRE AND SMOKE ZONE BARRIER
2-HOUR FIRE BARRIER
SUBSTANTIAL WALLS AND DOORS TO DIVIDE EACH FLOOR INTO COMPARTMENTS FOR DEFEND IN PLACE EMERGENCY OPERATIONS. IF THE SMOKE ZONE BARRIER WALL IS OF MASONRY, GYPSUM BOARD, OR METAL LATH AND PLASTER CONSTRUCTION, AND THE BARRIER WAS CONSTRUCTED POST 1948, THE SMOKE ZONE BARRIER WALLS ARE REQUIRED TO BE OF 1 HOUR FIRE RESISTANCE RATING. (NFPA 101, 18.3.2.7.5) SMOKE ZONE BARRIER WALLS OF WOOD LATH AND PLASTER CONSTRUCTION ARE PERMITTED TO BE OF A 1/2 HOUR FIRE RESISTANCE RATING (NFPA 101, 19.3.7.3)
WALL: WALL EXTENDS FROM FLOOR TO DECK ABOVE.
DUCTS: ALL DUCT PENETRATIONS ARE PROTECTED BY SMOKE DAMPERS. SMOKE
DAMPERS ARE NOT REQUIRED WHERE ADJACENT SMOKE COMPARTMENTS ARE
PROTECTED BY QUICK RESPONSE SPRINKLERS THROUGHOUT EACH
COMPARTMENT.
PENETRATIONS: ALL PENETRATIONS ARE SEALED WITH LISTED FIRESTOP MATERIALS FOR
PROTECTING 1-HOUR FIRE AND SMOKE WALL ASSEMBLIES. PENETRATIONS ARE
TO BE FILLED ON BOTH SIDES OF THE WALL.
DOORS: ALL DOORS FOR SMOKE BARRIERS REQUIRE THE FOLLOWING:
1. NON-LABELED FRAME (NFPA 101 18.3.7.6)
2. 20 MINUTE OR SOLID WOOD CORE (NFPA 101 18.3.7.6) 1 3/4" THICK.
3. MAXIMUM SIZE LISTED WINDOW (NFPA 80 TABLES 4.4.5)
4. POSITIVE LATCHING NOT REQUIRED (NFPA 101 18.3.7.8)
5. SELF CLOSING OR AUTOMATIC CLOSING (NFPA 101 18.3.7.8)
6. MAXIMUM 1/8" GAP (NFPA 101 18.3.7.6.)
7. MAXIMUM 3/4" UNDERCUT (NFPA 101 8.5.4)
8. UNLIMITED IN HEIGHT PROTECTIVE PLATE (NFPA 101 18.3.7.6/19.3.7.6.1
9. SWING IN DIRECTION OPPOSITE OF EACH OTHER (NFPA 101 18.3.7.6)
10. SMOKE DOOR ASSEMBLIES SHALL BE TESTED AT LEAST ANNUALLY (NFPA 105
5.2.1.1)
FIRE EXTINGUISHERFE
L E G E N D
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
100% CONSTRUCTION
DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
FFE INC
110 Boggs Lane, Suite 170
Springdale, OH 45246
513-522-0956
C U s e rs
\c ra ig \D o c u m e n ts \F t T h o m a s c ra ig .l ie g ib e l@ ff e
-s e rv .c o m
.r v t
/2
/2
:3
:1
P
M
GI001
LIFE SAFETY PLAN CORRECT FCA DEFICIENCIES -
FTD INTERIOR DEFICIENCIES
FT THOMAS, KY 41075
539-20-211
BUILDING 64
05/01/20 Checker Author
1/16" = 1'-0"
BASEMENT LIFE SAFETY PLAN
1/16" = 1'-0"
FIRST FLOOR LIFE SAFETY PLAN
Revisions: Date:
100% Construction/BID Documents 05/01/2020
INTERIOR STUD GAGE AND SPACING CHART*
STUD
WIDTH
DESIGN
THICKNESS
(GAGE)
STUD
SPACING
(INCHES)
PARTITION HEIGHT
DEFLECTION VALUE 5 psf
BRACING
SPACING WHERE
OCCURSL/120 L/240 L/360
1 5/8"
0.0179 " (25)
0.0312" (20)
0.0179 " (25)
0.0312" (20)
0.0179 " (25)
0.0312" (20)
0.0179 " (25)
0.0312" (20)
0.0179 " (25)
0.0312" (20)
2 1/2"
3 5/8"
4"
6"
16"
24"
16"
24"
16"
24"
16"
24"
16"
24"
16"
24"
16"
24"
16"
24"
16"
24"
16"
24"
10'-7"
9'-9"
12'-1"
11'-0"
13'-3"
11'-10"
16'-5"
14'-10"
15'-4"
13'-9"
20'-8"
18'-6"
17'-2"
15'-1"
23'-1"
20'-9"
19'-9"
16'-9"
30'-10"
27'-2"
8'-4"
7'-11"
9'-8"
8'-9"
11'-3"
10'-7"
12'-10"
11'-7"
14'-4"
13'-5"
16'-5"
14'-9"
15'-4"
14'-2"
18'-4"
16'-5"
19'-9"
16'-9"
24'-6"
21'-7"
8'-5"
7'-8"
9'-10"
9'-3"
11'-2"
10'-0"
12'-4"
11'-7"
14'-3"
12'-9"
13'-4"
12'-4"
15'-11"
14'-3"
17'-11"
16'-9"
21'-4"
18'-10"
4'-0" OC
4'-0" OC
4'-0" OC
4'-0" OC
6'-0" OC
6'-0" OC
6'-0" OC
6'-0" OC
8'-0" OC
8'-0" OC
8'-0" OC
8'-0" OC
8'-0" OC
8'-0" OC
8'-0" OC
8'-0" OC
10'-0" OC
10'-0" OC
10'-0" OC
10'-0" OC
1. PROVIDE MINIMUM 0.0312" STUDS AT WALLS TO RECEIVE FINISH (TILE, STONE, WOOD, ETC.)
2. PROVIDE MINIMUM 0.0312" STUDS AT JAMBS OF DOOR AND FIXED GLASS FRAMES, AT OPEN
PARTITION ENDS, AND WHERE PARTITION IS TO RECEIVE WALL MOUNTED SHELVES,
CASEWORK, PLUMBING FIXTURES, ETC.
3. USE 5/8" FR GWB AT ALL FIRE-RATED PARTITIONS, ANCHOR W/ SCREWS AT 8" OC ON EDGES
AT 12" OC IN FIELD PER UL DESIGN NUMBERS LISTED.
4. SEE ALL SPECIFICATIONS FOR GWB REQUIREMENTS AT TOILETS AND ALL WET AREAS.
5. FOR LOCATIONS OF EXISTING AND NEW FIRE-RATED PARTITIONS, SEE LIFE SAFETY PLANS.
6. PROVIDE ADDITIONAL BRACING AS REQUIRED AT ALL WALL STUD INSTALLATIONS EXCEEDING
STUD MANUFACTURER REQUIREMENTS FOR MAXIMUM ALLOWED HEIGHT AND DEFLECTION.
INTERIOR STUD CHART NOTES:
* REFERENCE STEEL STUD MANUFACTURER ASSOCIATION'S STANDARDS FOR SECTION PROPERTIES
AND DESIGN OF STUD SIZE LISTED HERE
USE L/240 DEFLECTION CHART FOR ALL AREA UNLESS OTHERWISE NOTED.
S T U D G A G E N O T E S
M
IN
2'-6" MIN
M A
X
M
IN
SINK
CLEAR FLOOR
SPACE
M
IN
GREATER THAN 24" DEEP
2'-6" MIN 3'-0" IF ALCOVE
URINAL
CLEAR FLOOR SPACE
5' - 0"
F
L O
O R
M O
U N
T
W
A L
L H
U N
G
1'-6" MAX
1'-4" MIN
WATER CLOSET
CLEAR FLOOR SPACE
CLEARANCE AT WATER CLOSET CLEARANCE AT SINK CLEARANCE AT URINAL
MAX
1'-0" 3'-6"
1' -7
M
A X
T O
S E
A T
1' -5
M
IN
T O
O U
T
LE
T O
F D
IS
P
E N
S E
R
1' -3
M
IN
T
O
'-0
M A
X A
F F
3' -0
M
A X
T O
B A
R
2' -9
M
IN
9" MAX
7" MIN
GRAB BAR
1"
SANITARY NAPKIN DISPOSAL
AT WOMEN RESTROOM
GRAB BAR
3' -0
M
A X
T O
B A
R
2' -9
M
IN
1'-6" MAX
1'-4" MIN
SANITARY NAPKIN DISPOSAL
AT WOMEN RESTROOM
1 1/2"
3'-0" MIN
6" MAX
2'-0" MIN 1'-0" MIN.
3'-0" MAX
3' -5
M
A X
3' -3
M
IN
1'
-6
M
IN
3'-5" MAX
3'-3" MIN VERTICAL GRAB BAR
TOILET PAPER
DISPENSER
4'-6" MIN
3' -5
M
A X
3' -3
M
IN
1'
-6
M
IN
SIDE WALL REAR WALL
VERTICAL GRAB BAR
FLOOR CLEARANCE
5'-0"
MIN
1'-3"
C
LR
K N
E E
S P
A C
E
2' -3
M
IN
M A
X T
O R
IM
2' -1
0"
R E
F
LE
C T
E D
S U
R F
A C
E O
F M
IR
R
O R
3' -4
M
A X
T O
B O
MIRROR - VERIFY SIZE
WITH PLANS AND
ELEVATIONS
MIN
8" DEEP
T O
R
IM
2' -1
0" M
A X
2'-1" MAX
1'-5" MIN
9" M
IN
9" M
IN
SIDE VIEW FRONT VIEW
CLEARANCE
6" MAX TOE
1'-5" MIN
LAVATORY
PLUMBING LINES
WITHIN HATCHED
AREA REQUIRED
TO BE INSULATED
LINES OF REQUIRED
CLEARANCE
FINISH FLOOR
4'-0" MIN CLR
2' -5
M
IN
5"
2' -3
M
IN
CLEAR SPACE
ALLOWABLE FOR
ACCESSIBILITY
MIRROR
2' -5
M
IN
LINES OF REQUIRED
CLEARANCE
5"
POSTURE MIRROR GARMENT HOOK
SHOWER CURTAIN ROD
T O
B O
T T
O M
M
A X
SOAP DISH
SHOWER HEAD
M A
X A
F F
A
B O
V E
S
IN
K T
O B
/O R
E F
L S
U R
F A
C E
MIRROR TOILET PAPER
DISPENSER
M
A X
M
IN
SANITARY NAPKIN
DISPOSAL UNIT
BARIATRIC SHOWER SEAT
M
A X
M
IN
1. TYPICAL PARTITION TYPE IS WALL TYPE "1" UNLESS NOTED OTHERWISE ON PLAN.
2. BUILD PARTITIONS IN ACCORDANCE WITH PARTITION SCHEDULE AND DESIGN REFERENCED. REFERENCES ARE TO LATEST EDITION OF GYPSUM ASSOCIATION (GA) FIRE RESISTANCE DESIGN MANUAL, OR TO
UNDERWRITERS LABORATORY (UL) FIRE RESISTANCE DIRECTORY.
3. ALL WALLBOARD IS TO BE TYPE "X" UNLESS NOTED OTHERWISE.
4. PARTITION TYPES INDICATED ARE CONTINUOUS TO A CORNER OR AN INTERSECTING PARTITION, UNLESS INDICATED OTHERWISE. WHERE PARTITIONS OF DIFFERENT THICKNESSES MEET, MAINTAIN A FLUSH SURFACE ON THE SIDE WHERE FACES ARE STRAIGHT AND CONTINUOUS, UNLESS NOTED OTHERWISE.
5. METAL STUD GAUGES SCHEDULED ARE THE MINIMUM REQUIRED, AND MAY BE INCREASED BY
SPECIFICATIONS TO ACCOMMODATE LOADS, FINISHES, OR UNBRACED CEILING HEIGHT LIMITS. DO NOT
CONSIDER CEILING SYSTEM(S) AS A PARTITION BRACING ELEMENT.
6. SOUND ATTENUATION BATTS (SAB) ARE TO BE PLACED IN ALL PARTITIONS WHICH ENCLOSE A ROOM
UNLESS NOTED OTHERWISE.
7. WOOD AND PLYWOOD BLOCKING TO BE FIRE RETARDANT TREATED (FRT).
8. EDGES OF GYPSUM WALL BOARD (GWB) LEFT EXPOSED TO VIEW, OR ABUTTING DISSIMILAR MATERIAL, IS
TO BE FINISHED WITH METAL "L" BEAD TRIM AND COMPOUND UNLESS NOTED OTHERWISE.
9. PARTITION SCHEDULE IS BASED ON THE USE OF GYPSUM WALL BOARD (GWB), BUT FACING BOARD MAY VARY, DEPENDENT ON FINAL FINISH SCHEDULED FOR THAT PARTITION: USE CEMENTITIOUS BACKER BOARD (CBB) WHERE CERAMIC TILE SCHEDULED IN "WET" AREAS; USE MOISTURE RESISTANT BOARD (MR) WHERE CERAMIC TILE SCHEDULED IN "DRY" AREAS; USE GYPSUM LATH (BLUE BOARD) WHERE VENEER PLASTER IS SCHEDULED. SEE FINISH SCHEDULE AND SPECIFICATIONS FOR PARTICULARS. AT ALL
PLUMBING FIXTURES INSTALL 4X8 (MR) MOISTURE RESISTANT BOARD CENTERED ON FIXTURE.
10. ALL FIRE RATED WALL AND FLOOR PENETRATION MUST COMPLY WITH ASTM-E814
11. ALL DOOR OPENINGS SHALL BE 4" FROM A PERPENDICULAR PARTITION TO OUTSIDE FACE OF FRAME, UNLESS NOTED OR DETAILED OTHERWISE.
12. ALL PARTITIONS, INCL. STUDS, BOARD, SOUND ATTENUATION BLANKETS, ETC. TO EXTEND FROM TOP OF
FLOOR SLAB TO UNDERSIDE OF CONCRETE SLAB ABOVE UNLESS OTHERWISE NOTED.
13. CONTRACTOR IS TO CLOSE OFF ANY VOIDS LEFT AS A RESULT OF ANY REMOVALS AND NEW CONSTRUCTION, AS WELL AS INFILL ANY EXISTING VOIDS IN NEWLY DESIGNATED FIRE RATED PARTITIONS.
ALL PATCHES SHALL MATCH AND ALIGN WITH SURROUNDING MATERIALS AND SHALL BE IN ACCORDANCE
WITH NFPA CODE.
14. REFER TO NEW ARCHITECTURAL FLOOR PLANS FOR PARTITION TYPE DESIGNATIONS.
15. CONTRACTOR SHALL SEAL PARTITION WALLS AROUND ALL M.E.P. PENETRATIONS OR OPENINGS, RESULTING FROM M.E.P. INSTALLATIONS INCLUDING BUT NOT LIMITED TO THE SLAB, ABOVE AND BELOW
CEILINGS.
16. ALL NEW MASONRY WORK INCLUDING NEW PARTITIONS, INFILL AND PATCHING; MATCH EXISTING COURSING
AND TOOTH IN WITH EXISTING ADJ. CONSTRUCTION.
17. NO EXISTING FIREPROOFING IS TO BE REMOVED FROM EXISTING BUILDING STRUCTURE FOR ANY NEW
INSTALLATION FOR ANY REASON.
18. IN AREAS OF TOILET ROOMS AND OTHER PLUMBING FIXTURES SUCH AS MOP BASINS, SINKS, SHOWERS, TOILETS, ETC. A TYPE 'X' MOISTURE RESISTANT GYPSUM WALLBOARD SHALL BE USED FOR THE WALL CONSTRUCTION. WHERE CERAMIC TILE IS SCHEDULED; CEMENTITIOUS BOARD SHALL BE USED FOR THE
WALL CONSTRUCTION.
19. UNLESS NOTED, THE CONNECTION AT THE TOP OF THE PARTITION TO THE STRUCTURE ABOVE MUST ALLOW FOR 1" MINIMUM VERTICAL MOVEMENT, EITHER UP OR DOWN. AT FIRE RATED METAL STUD PARTITIONS, THE TOP CONNECTION MUST BE A FIRE STOP CONNECTION THAT ALLOWS 1" MINIMUM VERTICAL MOVEMENT, EITHER UP OR DOWN. HOLD GYPSUM WALL BOARD AND STEEL STUDS 1" FROM THE BOTTOM OF THE STRUCTURE ABOVE. DO NOT SCREW-ATTACH STEEL VERTICAL STUDS OR GYPSUM WALL
BOARD TO THE TOP TRACK. INSTALL BRIDGING 12" MINIMUM FROM THE TOP OF THE STUDS.
P A R T I T I O N N O T E S
C1
10'-0"AFF
A101
SIM
A101
SIM
A101
SIM
A101
SIM
A B B R E V I A T I O N S
LEVEL NAME W/ ELEVATION
GRID HEAD
CALL OUT HEAD W/ SHEET NUMBER
ROOM NAME W/ ROOM NUMBER, AREA
BUILDING SECTION NUMBER W/ SHEET NUMBER
WALL SECTION NUMBER W/ SHEET NUMBER
DOOR NUMBER
WALL TAG
KEYNOTE
VIEW NAME WITH SCALE
REVISION TAG
CEILING TAG WITH HEIGHT
DETAIL SECTION NUMBER W/ SHEET NUMBER
NORTH ARROW
A.D.
A.C.T.
ACOUS.
A/C
A.C.P.
A.B.
AREA DRAIN
ACOUSTICAL CEILING TILE
ACOUSTIC
AIR CONDITIONING
ASPHALT CONCRETE
ANCHOR BOLT
PAVING
POUND OR NUMBER
PROPERTY LINE
FLOOR LINE
ANGLE
DIAMETER
CENTERLINE
AT
AND
BD.
APPROX.
ARCH.
ASPH.
ALT.
AL.
AGG.
BLDG.
BLK.
BLKG.
BM.
BRG.
BRK.
BOT.
BITUM.
CEM.
C.B.
CARP.
CAB.
B.U.R.
BTWN.
CLKG.
CLG.J.
CLG.
C.J.
CIR.
C.I.
CER.T.
CER.
BRZ.
COMB.
COL.
C.O.
CNTR.
CMU
CLS.
CLR.
C.W.
CTR.
CONV.O.
CONT.
CONST.
CONN.
CONC.
COMP.
DF.
D.F.
DIAG.
DIA.
DIM.
DISP.
DET.
DN.
D.O.
DR.
D.S.
D.T.
D.W.
DWR.
DIV.
CLO.
DOUGLAS FIR
DRINKING FOUNTAIN
DIAMETER
DIAGONAL
DIMENSION
DISPOSAL
DIVISION
DOWN
DOOR OPENING
DOOR
DOWN SPOUT
DRAIN TILE
DISHWASHER
DRAWER
DETAIL
COLD WATER
CENTER
CONVECTION OVEN
CONTINUOUS
CONSTRUCTION
CONNECTION
CONCRETE
COMPOSITION
BENCH MARK or BEAM
BOARD
BITUMINOUS
BUILDING
BLOCK
BLOCKING
APPROXIMATE
ARCHITECT
ASPHALT
CONCRETE MASONRY
COMBINATION
COLUMN
CLEAN OUT
COUNTER
CLOSURE
CLEAR
CLOSET
CAULKING
CEILING JOIST
UNIT
CEILING
BRICK
BEARING
CONSTRUCTION JOINT
CIRCLE
CAST IRON
CERAMIC TILE
CERAMIC
CEMENT
CATCH BASIN
CARPET
CABINET
BUILT-UP ROOFING
BETWEEN
BRONZE
BOTTOM
ALTERNATE
ALUMINUM
AGGREGATE
EA.
E.E.
E.F.
E.J.
ELEC.
ELEV.
E.N.
EXISTING
EACH
EACH END
EXHAUST FAN
EXPANSION JOINT
ELECTRICAL
ELEVATION
EDGE NAIL
(E)
ADJUSTABLEADJ.
LP
LC
LF
Ø
ABOVE FINISH FLOORAFF
CONTRACTOR FURNISH/
OWNER INSTALL
C.F.O.I.
C.F.C.I. CONTRACTOR FURNISH/
CONTRACTOR INSTALL
E.C. ELECTRICAL CONTRACTOR
C.HK. COAT HOOK
C.B.B. CEMENTITIOUS BACKER
BOARD
A.C.M. ASBESTOS CONTAINING
MATERIALS CW. CURTAINWALL
DWG(S). DRAWING(S)
FACE OF BUILDINGF.O.B.
FIXTURE
FACE OF CONCRETE
FLOOR
FLOOR JOIST
FLOOR LINE
FLASHING
FACE NAIL
GAUGE
FOOTING
FUTURE
FACE OF STUD
FIRE RETARDANT
TREATED WOOD
FACE OF MASONRY
FACE OF FINISH
F.O.S.
F.R.T.W.
FTG.
FUT.
GA.
FIXT.
F.J.
F.L.
FLASH.
FLR.
F.N.
F.O.C.
F.O.F.
F.O.M.
BEAM
GLASS
GLUE LAMINATED
GALVANIZED IRON
GRATE ELEVATION
GRAB BAR
GARBAGE DISPOSAL
GRADE
HOSE BIB
SHEET METAL
GYPSUM BOARD
HANDICAPPED
GALVANIZED
GROUND
HC.
GYP.BD.
H.B.
G.B.
G.D.
G.S.M.
GR.
GND.
GLB.
GL.
G.I.
G.E.
HEIGHT
HOUR
HEATING
HIGH POINT
HORIZONTAL
HOLLOW METAL
HARDWARE
HARDWOOD
INTERIOR
INVERT
HOT WATER
INSULATION
INSIDE DIAMETER
& AIR CONDITIONING
HEATING, VENTILATION
H.W.
INV.
INT.
INSUL.
I.D.
HDWE.
HDWD.
H.V.A.C.
HTG.
HR.
H.P.
HORIZ.
H.M.
HGT.
HDR. HEADER
JOIST
JANITOR
KITCHEN
JOINT
LABORATORY
JOIST HANGER
LAG BOLT
LAVATORY
LAMINATE
J.H.
JAN.
L.B.
LAV.
LAM.
LAB.
KIT.
JT.
JST.
EQUIV.
E.S.
E.W.
EXP.
EXP.B.
EXPO.
EXT.
F.
ENCL.
F.B.
F.BD.
F.BELL
F.B.O.
F.D.
FDN.
FE
FH.M.S.
F.HORN
F.F.
F.G.
FGL.
F.H.
F.E.C.
F.A.
FH.W.S.
FIN.
F.H.S.
ENCLOSURE
EQUIVALENT
EACH SIDE
EACH WAY
EXPANSION
EXPANSION BOLT
EXPOSURE
EXTERIOR
FLAT HEAD MACHINE
SCREW
SCREW
FIRE HORN
FIRE HOSE STATION
FLAT HEAD WOOD
FINISH
FLOOR DRAIN
FOUNDATION
FIRE EXTINGUISHER
FIRE EXTINGUISHER
FINISH FLOOR
FINISH GRADE
FIBERGLASS
FIRE HYDRANT
CABINET
FIRE ALARM
FACE BRICK
FIREBOARD
FIRE BELL
FURNISHED BY OTHERS
FACE
GALV. GALVANIZED
HOLLOW STRUC. STL.H.S.S.
FLUORESCENTFLOUR.
GENERAL CONTRACTORG.C.
E.W.C. ELECTRIC WATER CLOSET
FIRE VALVE CABINETF.V.C.
FOOD SERVICE EQUIPMENT
CONTRACTOR
F.S.E.C.
H.V.A.C. CONTRACTORH.C.
FIRE SUPPRESSION
CONTRACTOR
F.S.C.
PLASTIC LAMINATEP.LAM.
O.H.W.S.
SCREW
OVAL HEAD WOOD
APPROVAL)
PAPER TOWEL DISPENSER
PAPER TOWEL
PARTITION
DOUGLAS FIR
PRESSURE TREATED
REFLECTED CEILING
RADIUS
RUBBER BASE
QUARRY TILE
POLYVINYL-CHLORIDE
RECEPTACLE
R.C.P.
Q.T.
RAD.
R.B.
P.T.D.
PTN.
P.T.R.
P.V.C.
P.T.D.F.
REDWOOD
REFERENCE
REINFORCING
ROOF HATCH
ROUND HEAD METAL
RESILIENT
REFRIGERATOR
ROOF DRAIN
SCREW
ROOM
RAIN WATER LEADER
ROUGH OPENING
ROUND HEAD WOOD
SCREW
RDWD.
R.H.W.S.
R.W.L.
R.O.
RM.
R.H.M.S.
R.H.
RESIL.
REINF.
REFR.
REF.
R.D.
LIGHT
MATERIAL
LOW POINT
LIVE LOAD
LEFT HAND
MAT.
LT.
L.P.
L.L.
L.H.
MANHOLE
MINIMUM
MEDIUM
MANUFACTURER
MEMBRANE
MECHANICAL
MEDICINE CABINET
MACHINE BOLT
METAL
MASONRY OPENING
METAL THRESHOLD
MISCELLANEOUS
MODULAR
MOISTURE RESISTANT
MIRROR
M.C.
M.B.
MIN.
MH.
MFG.
MEMB.
MED.
MECH.
MIR.
MISC.
M.O.
MOD.
M.R.
M.T.
MTL.
MAX. MAXIMUM
NORTH
NATURAL
OVER
NUMBER
NOMINAL
NOT TO SCALE
NOT IN CONTRACT
OBSCURE
OUTSIDE DIAMETER
STUD
OFFICE
OUTSIDE FACE OF
ON CENTER
OVERFLOW
OVERALL
N.T.S.
O/ O.A.
OBS.
O.C.
O.D.
O.F.
OFF.
O.F.S.
(NOT PART OF OSA
N.
NAT.
N.I.C.
NO.
NOM.
PAINT
PLATE
PERFORATED
FOOT
POUNDS PER CUBIC
PANEL EDGE NAILING
PRESSED METAL
PAIR
FRAME
FOOT
POUNDS PER LINEAR
PLYWOOD
POUNDS PER SQUARE
PROPERTY
PLASTER
P.
P.C.F.
P.E.N.
PERF.
PL.
PLAS.
P.L.F.
PLYWD.
P.M.F.
PR.
P.S.F.
PROP.
OPP. OPPOSITE
POINT
PULL STATION
POUNDS PER SQUARE
INCH
P.STA.
PT.
P.S.I.
FOOT
(N) NEW
PLAN
REQUIREDREQD.
NON-COMBUSTIBLENON/COM
PLUMBING CONTRACTORP.C.
MECHANICAL, ELECTRICAL,
PLUMBING
M.E.P.
FRAMED MIRRORMR.
ROBE HOOKR.HK.
MOP HOLDERMP.H.
MOUNTEDMTD.
PAINTEDPTD.
TONGUE AND GROOVE
DRAWINGS
SOUTH
SEE CIVIL DRAWINGS
STORM DRAIN
SOLID CORE WOOD DOOR
DRAWINGS
SHEET
SIMILAR
SLIDING
SHEATHING
SHOWER
SECTION
SEALANT
SEE ELECTRICAL
SOLID BLOCKING
SOAP DISPENSER
SEE ARCHITECTURAL
S.E.D.
SHR.
SHT.
SIM.
SL.
SHTG.
S.BLKG.
S.A.D.
S.
SECT.
SEAL.
S.DISP.
S.D.
S.C.D.
SCWD
SQUARE
DRAWINGS
SPECIFICATION
SOUNDPROOF
DRAWINGS
STATION
STEEL
STORAGE
STANDARD
SUSPENDED
STRUCTURAL
DRAWINGS
STAINLESS STEEL
SEE MECHANICAL
SANITARY SEWER
SEE STRUCTURAL
SQUARE FOOT (FEET)
THICK
TEMPERED
TELEPHONE
TERRAZZO
TACKBOARD
TOP OF CURB
TRANSOM
TOP OF PLATE
TOP OF WALL
TOILET PAPER DISPENSER
TOE NAIL
TOOL JOINT
TOP OF PAVEMENT
TOP AND BOTTOM
T.O.C.
T.O.P.
T.O.PL.
T.O.W.
T.P.D.
TRN.
S.M.D.
SPEC.
S.P.
SQ.
S.S.D.
S. STL.
STO.
STL.
STD.
STA.
S.S.
SQ. FT.
T.B.
T&B.
TEL.
TEMP.
TER.
T&G.
SUSP.
T.J.
T.N.
THK.
STRUC.
S.L.D. SEE LANDSCAPE
TYPICAL
UNLESS NOTED OTHERWISE
URINAL
UNFINISHED
TELEVISION
VENT TO ROOF
VERTICAL
VESTIBULE
VERIFY IN FIELD
VINYL TILE
VINYL COMPOSITION
TILE
VERTICAL GRAIN
WEST
WITH
WINDOW
WOOD
WATER CLOSET
VINYL WALL COVERING
WITHOUT
WEIGHT
YARD
WATER PROOF
WATER HEATER
WATER COOLER
WELDED WIRE FABRIC
WATER RESISTANT
W/O
W.W.F.
W.P.
W.R.
WT.
YD.
T.V.
TYP.
UNF.
U.N.O.
V.C.T.
VERT.
VEST.
V.G.
V.I.F.
UR.
V.W.C.
W.
W/
W.C.
V.T.R.
W.F.
W.H
WDW.
WD.
V.T.
T.S. TUBE STEEL
SELF ADHERED SHEET
MEMBRANE
S.A.S.M.
SELF ADHERED FLEXIBLE
FLASHING
S.A.F.F.
WITHINW/IN
UNDERSIDEU/S
SANITARY NAPKIN
DISPOSAL
S.N.D.
T.S.C.D. TOILET SEAT COVER
DISPENSER
SANITARY NAPKIN
DISPENSER
S.N.V.
TOP OF SEATT.O.S.
SOUND ATTENUATION
BATT
S.A.B.
Name
Elevation
1 View Name
1/8" = 1'-0"A101
ROOM NAME
150 SF
S Y M B O L S
V.A. FURNISHED / CONTRACTOR
INSTALLED
(VC)
V.A. FURNISHED AND INSTALLED(VV)
TYPE 1 (U.N.O.)
ONE LAYER OF 5/8" GYPSUM
WALLBOARD ON EACH SIDE OF
3-5/8" 20 GA. METAL STUDS @ 16"
O.C. WITH 3" SOUND ATTENUATION
BLANKETS IN STUD SPACE. EXTEND
STUDS, BOARD, AND BLANKETS
FULL HEIGHT TO DECK ABOVE.
ATTACH TO STRUCTURE ABOVE W/
VERTICAL SLIP CONNECTIONS. SEE
PARTITION NOTES THIS DWG.
TYPE 2
ONE LAYER OF 5/8" GYPSUM
WALLBOARD ON ROOM SIDE OF 3-5/8"
20 GA. METAL STUDS @ 16" O.C. WITH
3" SOUND ATTENUATION BLANKET IN
STUD SPACE. EXTEND STUDS,
BOARD AND SOUND BLANKETS FULL
HEIGHT TO DECK ABOVE. ATTACH TO
STRUCTURE ABOVE W/ VERTICAL
SLIP CONNECTIONS. SEE PARTITION
NOTES THIS DWG.
DEFLECTION HEAD
3 5/8" MTL STUD @ 16" 0.C.
5/8" TYPE X GYPSUM
BOARD, BOTH SIDES
5/8" TYPE X GYPSUM
BOARD, ONE SIDE
3" SOUND ATTENUATION
BLANKETS
1 2
M A
X
M A
X
13 1/2" MAX
M A
X
M A
X
13 1/2" MAX
ACCESSABLE URINAL CLEARANCE STANDARD URINAL CLEARANCE
FLUSH CONTROLS
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
100% CONSTRUCTION
DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
FFE INC
110 Boggs Lane, Suite 170
Springdale, OH 45246
513-522-0956
C U s e rs
\c ra ig \D o c u m e n ts \F t T h o m a s c ra ig .l ie g ib e l@ ff e
-s e rv .c o m
.r v t
/2
/2
:3
:2
P
M
GI002
WALL TYPES AND NOTES CORRECT FCA DEFICIENCIES -
FTD INTERIOR DEFICIENCIES
FT THOMAS, KY 41075
539-20-211
BUILDING 64
05/01/20 Checker Author
1/4" = 1'-0"
TYP. CLEAR FLOOR SPACES AT ACCESSIBLE FIXTURES
1/2" = 1'-0"
TYP. ACCESSIBLE WATER CLOSET CLEARANCE
1/2" = 1'-0"
TYP. ACCESSIBLE LAVATORY CLEARANCE
1/2" = 1'-0"
RESTROOM FIXTURES AND ACCESSORIES
1/2" = 1'-0"
URINAL CLEARANCE
KITCHEN
MECHANICAL
004C
COOLER
COOLER
FREEZER
010A
COOLER
DINING ROOM
MENS
LOCKER
025A
MENS RR
WOMENS
LOCKER
PHYS.
THERAPY
ENGINEERING
STORAGE
BOILER
ROOM
AD111
SOILED
LINEN
018D
H.W. TANK
007A
21 1
3 3
MENS
RESTROOM
MENS
SHOWER
156A
SOCIAL
WORK
SERVICE
PATIENT
TOILET
SHOWER
ROOM
108A
DAY ROOM &
LOUNGE
LIBRARY
LOBBY
WEIGHT
ROOM
RECEIVING
106G
OXYGEN
STORAGE
106D
AD112
AD112
GAS
STORAGE
029D
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
100% CONSTRUCTION
DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
FFE INC
110 Boggs Lane, Suite 170
Springdale, OH 45246
513-522-0956
C U s e rs
\c ra ig \D o c u m e n ts \F t T h o m a s c ra ig .l ie g ib e l@ ff e
-s e rv .c o m
.r v t
/2
/2
:3
:5
P
M
AD101
OVERALL DEMOLITION PLANS CORRECT FCA DEFICIENCIES -
FTD INTERIOR DEFICIENCIES
FT THOMAS, KY 41075
539-20-211
BUILDING 64
05/01/20 PQ Author
1/16" = 1'-0"
BASEMENT OVERALL DEMOLITION
1/16" = 1'-0"
FIRST FLOOR OVERALL DEMOLITION
1 REMOVE EXISTING COOLER AND ALL ASSOCIATED EQUIPMENT.
2 REMOVE EXISTING FREEZER AND ALL ASSOCIATED EQUIPMENT.
3 SEE NEW WORK PLANS FOR NEW BACKFLOW PREVENTER TO BE
INSTALLED IN THIS ROOM.
D E M O L I T I O N N O T E S
G E N E R A L N O T E S
A. REFER TO GI000 FOR GENREAL NOTES AND PHASING NOTES.
MENS
LOCKER
025A
MENS RR
WOMENS
LOCKER
CORRIDOR
C*B*3
EMPLOYEE
BREAK ROOM
TOILET
CORRIDOR
C*B*2
CANTEEN
REC. TEMP
HAC
024 1
TYP.
8 9 10
TYP.
8 9 10
8 9
13 TYP.
13TYP
TYP.
TYP.
15 TYP.
A. ALL WALL HUNG FIXTURES AND ACCESSORIES ARE TO BE REMOVED
UNLESS NOTED OTHERWISE.
G E N E R A L N O T E S
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
100% CONSTRUCTION
DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
FFE INC
110 Boggs Lane, Suite 170
Springdale, OH 45246
513-522-0956
C U s e rs
\c ra ig \D o c u m e n ts \F t T h o m a s c ra ig .l ie g ib e l@ ff e
-s e rv .c o m
.r v t
/2
/2
:3
:5
P
M
AD111
ENLARGED BASEMENT
DEMOLITION PLAN
CORRECT FCA DEFICIENCIES -
FTD INTERIOR DEFICIENCIES
FT THOMAS, KY 41075
539-20-211
BUILDING 64
05/01/20 PQ Author
1/4" = 1'-0"
BASEMENT ENLARGED DEMOLITION
1 REMOVE EXISTING DOOR, FRAME, AND ASSOCIATED HARDWARE SHOWN AS
DASHED.
2 REMOVE EXISTING LOCKER SHOWN AS DASHED.
3 REMOVE EXISTING TOILET PARTITIONS SHOWN AS DASHED AND ALL
ATTACHED ACCESSORIES.
4 REMOVE EXISTING LAVATORIES SHOWN AS DASHED. STORE FOR REUSE IN
NEW WORK. SEE PLUMBING DRAWINGS.
5 REMOVE EXISTING URINAL SHOWN AS DASHED AND ASSOCIATED GRAB
BARS. SEE PLUMBING DRAWINGS.
6 REMOVE EXISTING FLOOR MOUNTED WATER CLOSET SHOWN AS DASHED.
SEE PLUMBING DRAWINGS.
7 EXISTING MIRROR TO REMAIN
8 REMOVE EXISTING FLOOR FINISH IN THIS ROOM. PREPARE SURFACE FOR
NEW FLOOR FINISH. SEE NEW WORK DRAWINGS.
9 REMOVE EXISTING CEILING TILE AND GRID IN THIS ROOM. SEE NEW WORK
DRAWINGS.
10 REMOVE EXISTING WALL TILE IN THIS ROOM. PREPARE TO RECEIVE NEW
WALL FINISH -- SEE NEW WORK DRAWINGS.
11 NO WORK IN THIS AREA.
12 EXISTING LOCKERS TO REMAIN.
13 REMOVE EXISTING MIRROR AT LAVATORY
14 EXISTING MECHANICAL EQUIPMENT TO REMAIN.
15 REMOVE EXISTING GRAB BAR.
16 REMOVE EXISTING DOOR AND ASSOCIATED HARDWARE
D E M O L I T I O N N O T E S
RESTROOM
MENS
SHOWER
156A
KITCHENETTE
ELEVATOR
LOBBY
148A
2 BEDROOM
CORRIDOR
C*1*7
6 7
6 7
1 1 1
TYP.
8 11
TYP.
TYP.
TYP.
TYP.
TYP.
PATIENT
TOILET
SHOWER
ROOM
108A
SUPPLY
106B
AAMS
106A
PHARMACY
CORRIDOR
C*1*2
TYP. 5
TYP.
TYP.
TYP.
11 TYP.
TYP.
TYP.
TYP.
18 TYP.
TYP.
A. ALL WALL HUNG FIXTURES AND ACCESSORIES ARE TO BE REMOVED
UNLESS NOTED OTHERWISE.
G E N E R A L N O T E S
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
100% CONSTRUCTION
DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
FFE INC
110 Boggs Lane, Suite 170
Springdale, OH 45246
513-522-0956
C U s e rs
\c ra ig \D o c u m e n ts \F t T h o m a s c ra ig .l ie g ib e l@ ff e
-s e rv .c o m
.r v t
/2
/2
:3
:5
P
M
AD112
ENLARGED FIRST FLOOR
DEMOLITION PLANS
CORRECT FCA DEFICIENCIES -
FTD INTERIOR DEFICIENCIES
FT THOMAS, KY 41075
539-20-211
BUILDING 64
05/01/20 PQ Author
1/4" = 1'-0"
ENLARGED DEMOLITION PLAN - RM 156
1/4" = 1'-0"
ENLARGED DEMOLITION PLAN - RM 108
1 REMOVE EXISTING LAVATORIES SHOWN AS DASHED. STORE FOR REUSE IN
NEW WORK. SEE PLUMBING DRAWINGS.
2 REMOVE EXISTING URINAL SHOWN AS DASHED AND ASSOCIATED GRAB
BARS. SEE PLUMBING DRAWINGS.
3 REMOVE EXISTING FLOOR MOUNTED WATER CLOSET SHOWN AS DASHED.
SEE PLUMBING DRAWINGS.
4 REMOVE EXISTING TOILET PARTITIONS SHOWN AS DASHED AND ALL
ATTACHED ACCESSORIES.
5 REMOVE EXISTING WALL SHOWN AS DASHED - CAP ALL PLUMBING
APPURTENANCES TO BE COORDINATED WITH NEW WORK LOCATIONS.
6 REMOVE EXISTING WALL TILE IN THIS ROOM. PREPARE TO RECEIVE NEW
WALL FINISH -- SEE NEW WORK DRAWINGS.
7 REMOVE EXISTING CEILING TILE AND GRID IN THIS ROOM. SEE NEW WORK
DRAWINGS.
8 REMOVE ONE SIDE OF EXISTING PLUMBING WALL SHOWN AS DASHED - SEE
PLUMBING DRAWINGS FOR EXTENT OF REPLACED PIPING AND COORDINATE
WITH NEW WORK DRAWINGS.
9 REMOVE EXISTING WALL MOUNTED WATER CLOSET SHOWN AS DASHED.
SEE PLUMBING DRAWINGS.
10 REMOVE EXISTING WALL MOUNTED BENCH AND COAT RACK SHOWN AS
DASHED.
11 REMOVE EXISTING GRAB BAR.
12 REMOVE EXISTING DOOR, FRAME, AND ASSOCIATED HARDWARE SHOWN AS
DASHED.
13 REMOVE EXISTING SHOWER ROD AND CURTAIN.
14 REMOVE EXISTING WALL-MOUNTED METAL CABINET SHOWN AS DASHED.
15 EXISTING RECESSED PAPER TOWEL DISPENSER/DISPOSAL TO REMAIN.
16 REMOVE EXISTING RECESSED WASTE RECEPTACLE SHOWN AS DASHED.
17 REMOVE EXISTING MIRROR AT LAVATORY
18 REMOVE WALL MOUNTED SOAP DISPENSER
19 REMOVE EXISTING FLOOR TILE IN THIS ROOM - PREPARE TO RECEIVE NEW
FLOOR FINISH - SEE NEW WORK DRAWINGS
20 EXISTING FLOOR DRAIN TO REMAIN - SEE PLUMBING AND NEW WORK
DRAWINGS
D E M O L I T I O N N O T E S
TYP.
KITCHEN
COOLER
COOLER
FREEZER
010A
COOLER
DINING ROOM
FITNESS
CENTER
027A
MENS
LOCKER
025A
MENS RR
WOMENS
LOCKER
OCC.
THEREAPY
PHYS.
THERAPY
ELECT.
SUPPLY
ELECT.
SUPPLY
030A
ENGINEERING
STORAGE
BOILER
ROOM
AE111
H.W. TANK
007A
SOILED
LINEN
018D
MECHANICAL
004C
6 6
MENS
RESTROOM
MENS
SHOWER
156A
PATIENT
TOILET
SHOWER
ROOM
108A
DAY ROOM &
LOUNGE
LOBBY
WEIGHT
ROOM
RECEIVING
106G
OXYGEN
STORAGE
106D
AE112
AE112
GAS
STORAGE
029D
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
100% CONSTRUCTION
DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
FFE INC
110 Boggs Lane, Suite 170
Springdale, OH 45246
513-522-0956
C U s e rs
\c ra ig \D o c u m e n ts \F t T h o m a s c ra ig .l ie g ib e l@ ff e
-s e rv .c o m
.r v t
/2
/2
:3
:0
P
M
AE101
OVERALL NEW WORK PLANS CORRECT FCA DEFICIENCIES -
FTD INTERIOR DEFICIENCIES
FT THOMAS, KY 41075
539-20-211
BUILDING 64
05/01/20 PQ Author
1/16" = 1'-0"
BASEMENT OVERALL NEW WORK
1/16" = 1'-0"
FIRST FLOOR OVERALL NEW WORK
1 PROVIDE NEW INSULATED WALK-IN COOLER IN THIS ROOM. SEE MECHANICAL
DRAWINGS.
2 PROVIDE NEW INSULATED WALK-IN FREEZER IN THIS ROOM. SEE MECHANICAL
DRAWINGS.
3 PROVIDE NEW BACKFLOW PREVENTER AT WATER ENTRANCE IN THIS ROOM. SEE
PLUMBING DRAWINGS.
4 SEE MECHANICAL DRAWINGS FOR COOLER/FREEZER CONDENSER UNITS -
PROVIDE LANDSCAPE SCREENING TO BE PROVIDED BY VA.
5 THIS ROOM IS DESIGNATED AS CONSTRUCTION LAYDOWN AREA. EXISTING
STORAGE WILL BE RELOCATED BY THE VA PRIOR TO CONSTRUCTION
6 PREPARE FLOOR TO BE LEVEL PER COOLER AND FREEZER MANUFACTURER'S
REQUIREMENTS.
D R A W I N G N O T E S
G E N E R A L N O T E S
A. REFER TO GI000 FOR GENREAL NOTES AND PHASING NOTES.
CORRIDOR
C*B*2
TOILET
022 CORRIDOR
C*B*3
CANTEEN
REC. TEMP
WOMENS
LOCKER
MENS RR
HAC
MENS
LOCKER
025A
EMPLOYEE
BREAK ROOM
/2
/8
4' - 4"
5' - 0"
3' - 10"
/2
4' - 0"
4' - 8" +/-
10 TYP. AT WC
M
IN
/8
4' - 0"
TYP
TYP
/4
3' - 8"
/2
14 14
TYP
10 1/2"7' - 11" 9' - 3 1/2" +/- 6' - 6"
18 18
8"3' - 4"
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
100% CONSTRUCTION
DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
FFE INC
110 Boggs Lane, Suite 170
Springdale, OH 45246
513-522-0956
C U s e rs
\c ra ig \D o c u m e n ts \F t T h o m a s c ra ig .l ie g ib e l@ ff e
-s e rv .c o m
.r v t
/2
/2
:3
:0
P
M
AE111
ENLARGED BASEMENT PLANS CORRECT FCA DEFICIENCIES -
FTD INTERIOR DEFICIENCIES
FT THOMAS, KY 41075
539-20-211
BUILDING 64
05/01/20 PQ Author
1/4" = 1'-0"
ENLARGED FLOOR PLAN - BASEMENT
1 WALL HUNG LAVATORY - REUSED AND RELOCATED FROM EXISTING WORK.
SEE PLUMBING DRAWINGS.
2 FOLD DOWN BARIATRIC SHOWER SEAT.
3 ACCESSIBLE TRANSFER SHOWER. SLOPE FLOOR TO DRAIN. SEE
PLUMBING DRAWINGS.
4 WALL MOUNTED STANDARD URINAL - SEE PLUMBING DRAWING
5 42" GRAB BAR.
6 NEW FLOORING, CEILING, AND WALL FINISH IN THIS ROOM - SEE ROOM
FINISH SCHEDULE.
7 36" GRAB BAR.
8 STAINLESS STEEL TOILET PARTITION - FLOOR MOUNTED - CONTINUOUS
PIANO HINGE
9 STAINLESS STEEL URINAL SCREEN - 18" X 42" - WALL MOUNTED WITH
CONTINUOUS STAINLESS STEEL PIANO HINGE
10 TOILET PAPER DISPENSER. (VC)
11 NEW DOUBLE PRONG ROBE HOOK.
12 SANITARY NAPKIN DISPOSAL UNIT. (VC)
13 NEW WALL-MOUNTED ACCESSIBLE WATER CLOSET. SEE PLUMBING
DRAWINGS.
14 SOAP DISPENSER. (VC)
15 PAPER TOWEL DISPENSER - SURFACE MOUNTED (VC)
16 MIRROR - 24W" X 36"H - INSTALL SO BOTTOM OF REFLECTIVE SURFACE IS
AT 3'-4" A.F.F.
17 EXISTING COLUMN TO REMAIN. BYPASS STRUCTURAL COLUMN WITH NEW
ADJACENT PLUMBING WALLS.
18 WASTE RECEPTACLE (VV)
19 NEW SHOWER CURTAIN ROD.
20 NEW SHOWER HEAD AND CONTROLS - SEE PLUMBING DRAWINGS.
21 WALL-MOUNTED ACCESSIBLE URINAL. SEE PLUMBING DRAWINGS.
D R A W I N G N O T E S
G E N E R A L N O T E S
A. REFER TO GI000 FOR GENREAL NOTES AND PHASING NOTES.
B. USE MOISTURE RESISTANT GYPSUM BOARD AT ALL RESTROOMS AND
LOCKER ROOMS NOT TO RECEIVE TILE BACKER BOARD.
C. ALL ITEMS ARE (CC) UNLESS NOTED OTHERWISE
P R O C U R M E N T L E G E N D
(CC) = CONTRACTOR FURNISHED/ CONTRACTOR INSTALLED
(VV) = VA FURNISHED/VA INSTALLED
(VC) = VA FURNISHED/CONTRACTOR INSTALLED
SHOWER
ROOM
108APATIENT
TOILET
CORRIDOR
C*1*2
PHARMACY
AAMS
106A
SUPPLY
106B
EQ EQ 5'-0" CLR.
V.I.F.
12' - 10" +/-
7 8
10 10
TYP.
TYP.
TYP.
TYP. AT WC
TYP
TYP
TYP
TYP
1 1
AE601
6' - 0"
MENS
RESTROOM
MENS
SHOWER
156A
CORRIDOR
C*1*7
KITCHENETTE
2 BEDROOM
TOILET
158A
3' - 0" 2' - 9"
1' - 6" 2' - 6" 2' - 6"
1' - 6"
5' - 6"
5' - 6" 1" 3' - 0" 1" 2' - 8"
1"
2' - 8"
5 5 5
TYP.
TYP.
/4
/8
/8
4' - 0"
17 4
TYP
TYP.
10"
TYP. AT WC
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
100% CONSTRUCTION
DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
FFE INC
110 Boggs Lane, Suite 170
Springdale, OH 45246
513-522-0956
C U s e rs
\c ra ig \D o c u m e n ts \F t T h o m a s c ra ig .l ie g ib e l@ ff e
-s e rv .c o m
.r v t
/2
/2
:3
:0
P
M
AE112
ENLARGED FIRST FLOOR PLANS CORRECT FCA DEFICIENCIES -
FTD INTERIOR DEFICIENCIES
FT THOMAS, KY 41075
539-20-211
BUILDING 64
05/01/20 PQ PRQ
1/4" = 1'-0"
ENLARGED FLOOR PLAN - RM 108
1/4" = 1'-0"
ENLARGED FLOOR PLAN - RM 156
1 FLOOR-MOUNTED ACCESSIBLE WATER CLOSET. SEE PLUMBING
DRAWINGS.
2 WALL MOUNTED STANDARD URINAL - SEE PLUMBING DRAWING
3 WALL-MOUNTED ACCESSIBLE URINAL. SEE PLUMBING DRAWINGS.
4 STAINLESS STEEL URINAL SCREEN - 18" X 42" - WALL MOUNTED WITH
CONTINUOUS STAINLESS STEEL PIANO HINGE
5 WALL HUNG LAVATORY - REUSED AND RELOCATED FROM EXISTING WORK.
SEE PLUMBING DRAWINGS.
6 36" ANTI-LIGATURE GRAB BAR.
7 48" ANTI-LIGATURE GRAB BAR.
8 FOLD DOWN BARIATRIC SHOWER SEAT.
9 42" ANTI-LIGATURE GRAB BAR.
10 NEW ANTI-LIGATURE SHOWER CURTAIN ROD.
11 NEW FLOORING, CEILING, AND WALL FINISH IN THIS ROOM - SEE ROOM
FINISH SCHEDULE.
12 NEW ANTI-LIGATURE DOUBLE PRONG ROBE HOOK.
13 ACCESSIBLE ROLL-IN SHOWER. SLOPE FLOOR TO DRAIN. PROVIDE
WATER STOP ALONG OPEN END OF SHOWER. SEE PLUMBING DRAWINGS.
14 ACCESSIBLE TRANSFER SHOWER. SLOPE FLOOR TO DRAIN. SEE
PLUMBING DRAWINGS.
15 RECESSED HOSE BIBB AT 18" AFF. SEE PLUMBING DRAWINGS.
16 18" ANTI-LIGATURE VERTICAL GRAB BAR.
17 STAINLESS STEEL TOILET PARTITION - FLOOR MOUNTED - CONTINUOUS
PIANO HINGE
18 TOILET PAPER DISPENSER. (VC)
19 MIRROR - 24W" X 36"H - INSTALL SO BOTTOM OF REFLECTIVE SURFACE IS
AT 3'-4" A.F.F.
20 SOAP DISPENSER. (VC)
21 PAPER TOWEL DISPENSER - SURFACE MOUNTED (VC)
22 NEW ANTI-LIGATURE SHOWER HEAD AND CONTROLS - SEE PLUMBING
DRAWINGS.
23 INFILL PORTION OF WALL AT REMOVED TRASH RECEPTACLE
24 WASTE RECEPTACLE (VV)
25 NEW FLOOR-MOUNTED BARIATRIC WATER CLOSET - SEE PLUMBING
DRAWINGS.
26 CEILING MOUNTED CURTAIN TRACK AND CURTAIN
D R A W I N G N O T E S
G E N E R A L N O T E S
A. REFER TO GI000 FOR GENREAL NOTES AND PHASING NOTES.
B. USE MOISTURE RESISTANT GYPSUM BOARD AT ALL RESTROOMS AND
LOCKER ROOMS NOT TO RECEIVE TILE BACKER BOARD.
C. ALL ITEMS ARE (CC) UNLESS NOTED OTHERWISE
D. AT ALL SHOWER LOCATIONS, SLOPE NEW TILE FLOORING TO EXISTING
DRAINS AT MIN. 1/4" PER FOOT.
E. SEE SHEET AE601 FOR TYPICAL TOILET PARTION ELEVATIONS.
P R O C U R E M E N T L E G E N D
(CC) = CONTRACTOR FURNISHED/ CONTRACTOR INSTALLED
(VV) = VA FURNISHED/VA INSTALLED
(VC) = VA FURNISHED/CONTRACTOR INSTALLED
LOCKER
025A
EMPLOYEE
BREAK ROOM
TOILET
CORRIDOR
C*B*3
WOMENS
LOCKER
MENS RR
HAC
7' - 10"
7' - 10"
7' - 10"
7' - 10"
7' - 8"
7' - 10"
44 44
7' - 6" 1
PATIENT
TOILET
SHOWER
ROOM
108A
PHARMACY
AAMS
106A
SUPPLY
106B
CORRIDOR
C*1*2
2 22
8' - 0"
8' - 0"
7' - 8"7' - 8" 7' - 8"
6 6
6 66
MENS
SHOWER
156A
MENS
RESTROOM
CORRIDOR
C*1*7
KITCHENETTE
2 BEDROOM
ELEVATOR
LOBBY
148A
TOILET
158A
8' - 0"
8' - 0"
7' - 8"
7' - 8"
6 6
2' X 4' LIGHTING FIXTURE
(EXISTING/RELOCATED)
L E G E N D
1' X 4' LIGHTING FIXTURE
(EXISTING/RELOCATED)
CAN LIGHT (NEW)
EXHAUST GRILLE - SEE MECHANICAL
(NEW)
2' X 4' LIGHTING FIXTURE
(EXISTING/RELOCATED)
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
100%…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .