About this file

This document contains an opportunity announcement for a federal construction contract and the related solicitation documents. The Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 10 intends to issue a solicitation for project number 539-20-211 to correct deficiencies at an FTD interior at the Cincinnati VAMC located at 3200 Vine Street in Cincinnati, Ohio. The scope of work involves renovations to restrooms, locker rooms, and installation of coolers and freezers. The total project value is between $500,000 and $1,000,000. The NAICS code is 238220 for commercial and institutional building construction with a size standard of $16.5 million. The solicitation is designated as a 100% set-aside for small business with an SDVOSB preference. The contract duration is 180 calendar days from notice to proceed. Bonds will be required. The solicitation and drawings will be posted on August 10, 2020.

View the file

Other files

File Type Posted
MH111.pdf PDF
ED000A - BASEMENT ELECTRICAL DEMO PLAN- AREA A.pdf PDF
FX101 - FIRE PROTECTION BASEMENT PLANS.pdf PDF
Asbestos Survey Report.pdf PDF
114121 Walk-In Coolers and Freezers.pdf PDF
AD112.pdf PDF
Site Visit Sign In Sheet.pdf PDF
EP000A - BASEMENT ELECTRICAL NEW WORK - AREA A.pdf PDF
2nd Sign in Sheet.pdf PDF
230511 Common Work Results for HVAC.pdf PDF
MD101.pdf PDF
AE101.pdf PDF
36C25020B0059 0002.docx DOCX document
AD111.pdf PDF
36C25020B0059 0001.docx DOCX document
Corbin Russwin Locksets Sole Source Justification - Redacted.pdf PDF
S02 RFI Form.docx DOCX document
S02 Contractor EMR Certification Form.docx DOCX document
539-20-211_Specifications (Combined).pdf PDF
100_ CD Drawings_Combined -07202020.pdf PDF
36C25020B0059.docx DOCX document
Wage Determination.pdf PDF
Show all 22

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

CORRIDOR

C*B*2

TOILET

022 CORRIDOR

C*B*3

CANTEEN

REC. TEMP

WOMENS

LOCKER

MENS RR

HAC

MENS

LOCKER

025A

EMPLOYEE

BREAK ROOM

1'

3" 1'

6"

5'

1/

2" 3'

7/ 8"

5'

7" 2'

2'

3'

3"

2'

6"

4'

6"

4'

0"

4' - 4"

5'

6" 1"

3'

0"

1'

9"

5' - 0"

3' - 10"

1" 2'

1/ 2"

1" 3'

0"

1" 5'

6"

4' - 0"

4' - 8" +/-

10 TYP. AT WC

M

IN

1'

7/

8" 4'

6"

4' - 0"

TYP

1'

6"

TYP

2'

3/

4"

3' - 8"

/2

14 14

TYP

10 1/2"7' - 11" 9' - 3 1/2" +/- 6' - 6"

18 18

8"3' - 4"

COOLER

COOLER

FREEZER

010A

COOLER

9' - 2 1/2" +/-

6' - 11 1/2" +/-

1'

7"

8' - 11 3/4" 5' - 4 1/4" 1' - 10"

10' - 1"

5'

1/

2"

5'

1/

2"

16' - 1 1/2"

CORRIDOR

C*B*1

OFFICE

009A

HCMI

OFFICE

H.W. TANK

007A

ELEC.

007B

BLDG

MANAG. OFF

2' - 0"

CLG. HEIGHT

7'-0" +/-

CLG. HEIGHT

8'-0" +/-

CLG. HEIGHT

8'-0" +/-

CLG. HEIGHT

8'-0" +/-

CLG. HEIGHT

8'-0" +/-

TYP.

TYP.

TYP.

31 TYP.

32 32

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

100% CONSTRUCTION

DOCUMENTS

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

FFE INC

110 Boggs Lane, Suite 170 Springdale, OH 45246 513-522-0956

C :\U se rs

\q ui nn \D oc um en ts

\F t T ho m as

(2

9)

_p at ric k.

qu in nF

BN

EU

.rv t 8/

/2

3:

:2

PM

AE111

ENLARGED BASEMENT PLANS CORRECT FCA DEFICIENCIES -

FTD INTERIOR DEFICIENCIES

FT THOMAS, KY 41075

539-20-211

BUILDING 64

05/01/20 PQ Author

1/4" = 1'-0"1 ENLARGED FLOOR PLAN - BASEMENT

1 WALL HUNG LAVATORY - REUSED AND RELOCATED FROM EXISTING WORK.

SEE PLUMBING DRAWINGS.

2 FOLD DOWN BARIATRIC SHOWER SEAT.

3 ACCESSIBLE TRANSFER SHOWER. SLOPE FLOOR TO DRAIN. SEE

PLUMBING DRAWINGS.

4 WALL MOUNTED STANDARD URINAL - SEE PLUMBING DRAWING

5 42" GRAB BAR.

6 NEW FLOORING, CEILING, AND WALL FINISH IN THIS ROOM - SEE ROOM

FINISH SCHEDULE.

7 36" GRAB BAR.

8 STAINLESS STEEL TOILET PARTITION - FLOOR MOUNTED - CONTINUOUS

PIANO HINGE

9 STAINLESS STEEL URINAL SCREEN - 18" X 42" - WALL MOUNTED WITH

CONTINUOUS STAINLESS STEEL PIANO HINGE

10 TOILET PAPER DISPENSER. (VC)

11 NEW DOUBLE PRONG ROBE HOOK.

12 SANITARY NAPKIN DISPOSAL UNIT. (VC)

13 NEW WALL-MOUNTED ACCESSIBLE WATER CLOSET. SEE PLUMBING

DRAWINGS.

14 SOAP DISPENSER. (VC)

15 PAPER TOWEL DISPENSER - SURFACE MOUNTED (VC)

16 MIRROR - 24W" X 36"H - INSTALL SO BOTTOM OF REFLECTIVE SURFACE IS

AT 3'-4" A.F.F.

17 EXISTING LOCKERS TO REMAIN.

18 WASTE RECEPTACLE (VV)

19 NEW SHOWER CURTAIN ROD.

20 NEW SHOWER HEAD AND CONTROLS - SEE PLUMBING DRAWINGS.

21 WALL-MOUNTED ACCESSIBLE URINAL. SEE PLUMBING DRAWINGS.

22 NEW FREEZER INSULATED PANEL WALLS AND CEILING – INSTALLATION

AND CLEARANCES PER MANUFACTURER’S REQUIREMENTS – MINIMUM 5”

PANEL SIZE.

23 NEW COOLER INSULATED PANEL WALLS AND CEILING – INSTALLATION AND

CLEARANCES PER MANUFACTURER’S REQUIREMENTS – MINIMUM 4”

PANEL SIZE. COOLERS DO NOT HAVE INSULATED PANEL FLOORS -

PROVIDE NEW STAINLESS STEEL BASE INCLUDED WITH WALL PANEL -

COMPLETELY SEAL UNDERSIDE OF WALL PANEL TO MAKE AIR TIGHT.

24 NEW 36" X 80" COOLER/FREEZER DOOR BY COOLER MANUFACTURER.

25 PROVIDE INTERMEDIATE PANEL TO DEMISE COOLER FROM FREEZER –

MINIMUM 5” PANEL THICKNESS.

26 STAINLESS STEEL TRIM AT ALL EXPOSED EDGES OF COOLER OPENING

INTO CORRIDOR.

27 PATCH V.C.T. FLOORING WITH VA-PROVIDED STOCK TILE TO MATCH

EXISTING. (VC)

28 NEW RAMP BY COOLER MANUFACTURER TO CONNECT EXISTING

CORRIDOR ELEVATION WITH EXISTING COOLER FLOOR ELEVATION

(APPROXIMATELY 3" +/- RISE, VERIFY IN FIELD).

29 NEW FREEZER INSULATED PANEL FLOORING – MINIMUM 4” DEPTH -

PROVIDE INTERNAL RAMP BY FREEZER MANUFACTURER – MINIMUM 24”

RUN.

30 ALIGN NEW WALL PANEL WITH EDGE OF DEMOLISHED WALL PANEL

LOCATION TO CONCEAL ANY IRREGULARITIES IN FLOOR FINISH.

31 SEAL AND CONNECT COOLER TO FREEZER - DETAILS PER COOLER

MANUFACTURER.

32 REINSTALL EXISTING SIGNAGE (R) CENTERED AT 5'-0" A.F.F. AT STRIKE

SIDE OF DOOR.

33 LINE AT BULKHEAD ABOVE - CEILING HEIGHT MAY VARY AROUND EXISTING

UNKNOWN CONSTRUCTION ABOVE CEILING - MAXIMIZE SPACE AVAILABLE

WITH NEW COOLER INSTALLATION.

D R A W I N G N O T E S

G E N E R A L N O T E S

A. REFER TO GI000 FOR GENERAL NOTES AND PHASING NOTES.

B. USE MOISTURE RESISTANT GYPSUM BOARD AT ALL RESTROOMS AND

LOCKER ROOMS NOT TO RECEIVE TILE BACKER BOARD.

C. ALL ITEMS ARE (CC) UNLESS NOTED OTHERWISE

D. CONTRACTOR SHALL VERIFY ALL EXISTING DIMENSIONS AND SPACES

PRIOR TO FABRICATION OF COOLER / FREEZERS.

P R O C U R M E N T L E G E N D

(CC) = CONTRACTOR FURNISHED/ CONTRACTOR INSTALLED

(VV) = VA FURNISHED/VA INSTALLED

(VC) = VA FURNISHED/CONTRACTOR INSTALLED

(R) = RELOCATED FROM EXISTING LOCATION

Revisions: Date:

100% Construction/BID Documents 05/01/2020 Addendum #2 09/02/2020

1/4" = 1'-0"2 ENLARGED FLOOR PLAN - COOLERS / FREEZER

Sheets
AE111 - ENLARGED BASEMENT PLANS

File details come from the government source that posted it. Updated .