AE111.pdf
PDF 546 KB Posted
- Solicitation number
- 36C25020B0059
About this file
This document contains an opportunity announcement for a federal construction contract and the related solicitation documents. The Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 10 intends to issue a solicitation for project number 539-20-211 to correct deficiencies at an FTD interior at the Cincinnati VAMC located at 3200 Vine Street in Cincinnati, Ohio. The scope of work involves renovations to restrooms, locker rooms, and installation of coolers and freezers. The total project value is between $500,000 and $1,000,000. The NAICS code is 238220 for commercial and institutional building construction with a size standard of $16.5 million. The solicitation is designated as a 100% set-aside for small business with an SDVOSB preference. The contract duration is 180 calendar days from notice to proceed. Bonds will be required. The solicitation and drawings will be posted on August 10, 2020.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| MH111.pdf | ||
| ED000A - BASEMENT ELECTRICAL DEMO PLAN- AREA A.pdf | ||
| FX101 - FIRE PROTECTION BASEMENT PLANS.pdf | ||
| Asbestos Survey Report.pdf | ||
| 114121 Walk-In Coolers and Freezers.pdf | ||
| AD112.pdf | ||
| Site Visit Sign In Sheet.pdf | ||
| EP000A - BASEMENT ELECTRICAL NEW WORK - AREA A.pdf | ||
| 2nd Sign in Sheet.pdf | ||
| 230511 Common Work Results for HVAC.pdf | ||
| MD101.pdf | ||
| AE101.pdf | ||
| 36C25020B0059 0002.docx | DOCX document | |
| AD111.pdf | ||
| 36C25020B0059 0001.docx | DOCX document | |
| Corbin Russwin Locksets Sole Source Justification - Redacted.pdf | ||
| S02 RFI Form.docx | DOCX document | |
| S02 Contractor EMR Certification Form.docx | DOCX document | |
| 539-20-211_Specifications (Combined).pdf | ||
| 100_ CD Drawings_Combined -07202020.pdf | ||
| 36C25020B0059.docx | DOCX document | |
| Wage Determination.pdf |
Show all 22
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
CORRIDOR
C*B*2
TOILET
022 CORRIDOR
C*B*3
CANTEEN
REC. TEMP
WOMENS
LOCKER
MENS RR
HAC
MENS
LOCKER
025A
EMPLOYEE
BREAK ROOM
1'
3" 1'
6"
5'
1/
2" 3'
7/ 8"
5'
7" 2'
2'
3'
3"
2'
6"
4'
6"
4'
0"
4' - 4"
5'
6" 1"
3'
0"
1'
9"
5' - 0"
3' - 10"
1" 2'
1/ 2"
1" 3'
0"
1" 5'
6"
4' - 0"
4' - 8" +/-
10 TYP. AT WC
M
IN
1'
7/
8" 4'
6"
4' - 0"
TYP
1'
6"
TYP
2'
3/
4"
3' - 8"
/2
14 14
TYP
10 1/2"7' - 11" 9' - 3 1/2" +/- 6' - 6"
18 18
8"3' - 4"
COOLER
COOLER
FREEZER
010A
COOLER
9' - 2 1/2" +/-
6' - 11 1/2" +/-
1'
7"
8' - 11 3/4" 5' - 4 1/4" 1' - 10"
10' - 1"
5'
1/
2"
5'
1/
2"
16' - 1 1/2"
CORRIDOR
C*B*1
OFFICE
009A
HCMI
OFFICE
H.W. TANK
007A
ELEC.
007B
BLDG
MANAG. OFF
2' - 0"
CLG. HEIGHT
7'-0" +/-
CLG. HEIGHT
8'-0" +/-
CLG. HEIGHT
8'-0" +/-
CLG. HEIGHT
8'-0" +/-
CLG. HEIGHT
8'-0" +/-
TYP.
TYP.
TYP.
31 TYP.
32 32
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
100% CONSTRUCTION
DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
FFE INC
110 Boggs Lane, Suite 170 Springdale, OH 45246 513-522-0956
C :\U se rs
\q ui nn \D oc um en ts
\F t T ho m as
(2
9)
_p at ric k.
qu in nF
BN
EU
.rv t 8/
/2
3:
:2
PM
AE111
ENLARGED BASEMENT PLANS CORRECT FCA DEFICIENCIES -
FTD INTERIOR DEFICIENCIES
FT THOMAS, KY 41075
539-20-211
BUILDING 64
05/01/20 PQ Author
1/4" = 1'-0"1 ENLARGED FLOOR PLAN - BASEMENT
1 WALL HUNG LAVATORY - REUSED AND RELOCATED FROM EXISTING WORK.
SEE PLUMBING DRAWINGS.
2 FOLD DOWN BARIATRIC SHOWER SEAT.
3 ACCESSIBLE TRANSFER SHOWER. SLOPE FLOOR TO DRAIN. SEE
PLUMBING DRAWINGS.
4 WALL MOUNTED STANDARD URINAL - SEE PLUMBING DRAWING
5 42" GRAB BAR.
6 NEW FLOORING, CEILING, AND WALL FINISH IN THIS ROOM - SEE ROOM
FINISH SCHEDULE.
7 36" GRAB BAR.
8 STAINLESS STEEL TOILET PARTITION - FLOOR MOUNTED - CONTINUOUS
PIANO HINGE
9 STAINLESS STEEL URINAL SCREEN - 18" X 42" - WALL MOUNTED WITH
CONTINUOUS STAINLESS STEEL PIANO HINGE
10 TOILET PAPER DISPENSER. (VC)
11 NEW DOUBLE PRONG ROBE HOOK.
12 SANITARY NAPKIN DISPOSAL UNIT. (VC)
13 NEW WALL-MOUNTED ACCESSIBLE WATER CLOSET. SEE PLUMBING
DRAWINGS.
14 SOAP DISPENSER. (VC)
15 PAPER TOWEL DISPENSER - SURFACE MOUNTED (VC)
16 MIRROR - 24W" X 36"H - INSTALL SO BOTTOM OF REFLECTIVE SURFACE IS
AT 3'-4" A.F.F.
17 EXISTING LOCKERS TO REMAIN.
18 WASTE RECEPTACLE (VV)
19 NEW SHOWER CURTAIN ROD.
20 NEW SHOWER HEAD AND CONTROLS - SEE PLUMBING DRAWINGS.
21 WALL-MOUNTED ACCESSIBLE URINAL. SEE PLUMBING DRAWINGS.
22 NEW FREEZER INSULATED PANEL WALLS AND CEILING – INSTALLATION
AND CLEARANCES PER MANUFACTURER’S REQUIREMENTS – MINIMUM 5”
PANEL SIZE.
23 NEW COOLER INSULATED PANEL WALLS AND CEILING – INSTALLATION AND
CLEARANCES PER MANUFACTURER’S REQUIREMENTS – MINIMUM 4”
PANEL SIZE. COOLERS DO NOT HAVE INSULATED PANEL FLOORS -
PROVIDE NEW STAINLESS STEEL BASE INCLUDED WITH WALL PANEL -
COMPLETELY SEAL UNDERSIDE OF WALL PANEL TO MAKE AIR TIGHT.
24 NEW 36" X 80" COOLER/FREEZER DOOR BY COOLER MANUFACTURER.
25 PROVIDE INTERMEDIATE PANEL TO DEMISE COOLER FROM FREEZER –
MINIMUM 5” PANEL THICKNESS.
26 STAINLESS STEEL TRIM AT ALL EXPOSED EDGES OF COOLER OPENING
INTO CORRIDOR.
27 PATCH V.C.T. FLOORING WITH VA-PROVIDED STOCK TILE TO MATCH
EXISTING. (VC)
28 NEW RAMP BY COOLER MANUFACTURER TO CONNECT EXISTING
CORRIDOR ELEVATION WITH EXISTING COOLER FLOOR ELEVATION
(APPROXIMATELY 3" +/- RISE, VERIFY IN FIELD).
29 NEW FREEZER INSULATED PANEL FLOORING – MINIMUM 4” DEPTH -
PROVIDE INTERNAL RAMP BY FREEZER MANUFACTURER – MINIMUM 24”
RUN.
30 ALIGN NEW WALL PANEL WITH EDGE OF DEMOLISHED WALL PANEL
LOCATION TO CONCEAL ANY IRREGULARITIES IN FLOOR FINISH.
31 SEAL AND CONNECT COOLER TO FREEZER - DETAILS PER COOLER
MANUFACTURER.
32 REINSTALL EXISTING SIGNAGE (R) CENTERED AT 5'-0" A.F.F. AT STRIKE
SIDE OF DOOR.
33 LINE AT BULKHEAD ABOVE - CEILING HEIGHT MAY VARY AROUND EXISTING
UNKNOWN CONSTRUCTION ABOVE CEILING - MAXIMIZE SPACE AVAILABLE
WITH NEW COOLER INSTALLATION.
D R A W I N G N O T E S
G E N E R A L N O T E S
A. REFER TO GI000 FOR GENERAL NOTES AND PHASING NOTES.
B. USE MOISTURE RESISTANT GYPSUM BOARD AT ALL RESTROOMS AND
LOCKER ROOMS NOT TO RECEIVE TILE BACKER BOARD.
C. ALL ITEMS ARE (CC) UNLESS NOTED OTHERWISE
D. CONTRACTOR SHALL VERIFY ALL EXISTING DIMENSIONS AND SPACES
PRIOR TO FABRICATION OF COOLER / FREEZERS.
P R O C U R M E N T L E G E N D
(CC) = CONTRACTOR FURNISHED/ CONTRACTOR INSTALLED
(VV) = VA FURNISHED/VA INSTALLED
(VC) = VA FURNISHED/CONTRACTOR INSTALLED
(R) = RELOCATED FROM EXISTING LOCATION
Revisions: Date:
100% Construction/BID Documents 05/01/2020 Addendum #2 09/02/2020
1/4" = 1'-0"2 ENLARGED FLOOR PLAN - COOLERS / FREEZER
| Sheets |
| AE111 - ENLARGED BASEMENT PLANS |
File details come from the government source that posted it. Updated .