AD112.pdf
PDF 488 KB Posted
- Solicitation number
- 36C25020B0059
About this file
This document contains details for a federal solicitation to correct deficiencies at a Veterans Affairs medical center. The Veterans Administration Cincinnati VAMC is seeking bids for Project #539-20-211 to correct FCA deficiencies and interior deficiencies at its facility located at 3200 Vine Street in Cincinnati, Ohio. The solicitation will be released on or about August 10, 2020 and can be found on www.beta.sam.gov. The project magnitude is estimated between $500,000 and $1,000,000. The NAICS code is 238220 for the construction of healthcare facilities and the size standard is $16.5 million. The duration of the project must not exceed 180 calendar days from receipt of the notice to proceed. The solicitation is set aside 100% for small businesses with a preference for service-disabled veteran-owned small businesses. Bidders must be registered and verified in the VIP and SAM databases. Successful bidders must provide safety, environmental, and experience modification violations history prior to award.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| MH111.pdf | ||
| ED000A - BASEMENT ELECTRICAL DEMO PLAN- AREA A.pdf | ||
| AE111.pdf | ||
| FX101 - FIRE PROTECTION BASEMENT PLANS.pdf | ||
| Asbestos Survey Report.pdf | ||
| 114121 Walk-In Coolers and Freezers.pdf | ||
| Site Visit Sign In Sheet.pdf | ||
| EP000A - BASEMENT ELECTRICAL NEW WORK - AREA A.pdf | ||
| 2nd Sign in Sheet.pdf | ||
| 230511 Common Work Results for HVAC.pdf | ||
| MD101.pdf | ||
| AE101.pdf | ||
| 36C25020B0059 0002.docx | DOCX document | |
| AD111.pdf | ||
| 36C25020B0059 0001.docx | DOCX document | |
| Corbin Russwin Locksets Sole Source Justification - Redacted.pdf | ||
| S02 RFI Form.docx | DOCX document | |
| S02 Contractor EMR Certification Form.docx | DOCX document | |
| 539-20-211_Specifications (Combined).pdf | ||
| 100_ CD Drawings_Combined -07202020.pdf | ||
| 36C25020B0059.docx | DOCX document | |
| Wage Determination.pdf |
Show all 22
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
MENS
RESTROOM
MENS
SHOWER
156A
KITCHENETTE
ELEVATOR
LOBBY
148A
2 BEDROOM
CORRIDOR
C*1*7
6 7
6 7
1 1 1
TYP.
8 11
TYP.
TYP.
TYP.
TYP.
TYP.
PATIENT
TOILET
SHOWER
ROOM
108A
SUPPLY
106B
AAMS
106A
PHARMACY
CORRIDOR
C*1*2
TYP. 5
TYP.
TYP.
TYP.
11 TYP.
TYP.
3'
8" 3'
0"
TYP.
TYP. 18 TYP.
TYP.
A. ALL WALL HUNG FIXTURES AND ACCESSORIES ARE TO BE REMOVED
UNLESS NOTED OTHERWISE.
G E N E R A L N O T E S
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
100% CONSTRUCTION
DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
FFE INC
110 Boggs Lane, Suite 170 Springdale, OH 45246 513-522-0956
C :\U se rs
\q ui nn \D oc um en ts
\F t T ho m as
(2
9)
_p at ric k.
qu in nF
BN
EU
.rv t 8/
/2
2:
:1
PM
AD112
ENLARGED FIRST FLOOR
DEMOLITION PLANS
CORRECT FCA DEFICIENCIES -
FTD INTERIOR DEFICIENCIES
FT THOMAS, KY 41075
539-20-211
BUILDING 64
05/01/20 PQ Author
1/4" = 1'-0"2 ENLARGED DEMOLITION PLAN - RM 156
1/4" = 1'-0"1 ENLARGED DEMOLITION PLAN - RM 108
1 REMOVE EXISTING LAVATORIES SHOWN AS DASHED. STORE FOR REUSE IN
NEW WORK. SEE PLUMBING DRAWINGS.
2 REMOVE EXISTING URINAL SHOWN AS DASHED AND ASSOCIATED GRAB
BARS. SEE PLUMBING DRAWINGS.
3 REMOVE EXISTING FLOOR MOUNTED WATER CLOSET SHOWN AS DASHED.
SEE PLUMBING DRAWINGS.
4 REMOVE EXISTING TOILET PARTITIONS SHOWN AS DASHED AND ALL
ATTACHED ACCESSORIES.
5 REMOVE EXISTING WALL SHOWN AS DASHED - CAP ALL PLUMBING
APPURTENANCES TO BE COORDINATED WITH NEW WORK LOCATIONS.
6 REMOVE EXISTING WALL TILE IN THIS ROOM. PREPARE TO RECEIVE NEW
WALL FINISH -- SEE NEW WORK DRAWINGS.
7 REMOVE EXISTING CEILING TILE AND GRID IN THIS ROOM. SEE NEW WORK
DRAWINGS.
8 REMOVE ONE SIDE OF EXISTING PLUMBING WALL SHOWN AS DASHED - SEE
PLUMBING DRAWINGS FOR EXTENT OF REPLACED PIPING AND COORDINATE
WITH NEW WORK DRAWINGS.
9 REMOVE EXISTING WALL MOUNTED WATER CLOSET SHOWN AS DASHED.
SEE PLUMBING DRAWINGS.
10 REMOVE EXISTING WALL MOUNTED BENCH AND COAT RACK SHOWN AS
DASHED.
11 REMOVE EXISTING GRAB BAR.
12 REMOVE EXISTING DOOR, FRAME, AND ASSOCIATED HARDWARE SHOWN AS
DASHED.
13 REMOVE EXISTING SHOWER ROD AND CURTAIN.
14 REMOVE EXISTING RECESSED WASTE RECEPTACLE SHOWN AS DASHED.
15 EXISTING RECESSED PAPER TOWEL DISPENSER/DISPOSAL TO REMAIN.
16 REMOVE EXISTING WALL-MOUNTED PAPER TOWEL DISPENSER.
17 REMOVE EXISTING MIRROR AT LAVATORY
18 REMOVE WALL MOUNTED SOAP DISPENSER
19 REMOVE EXISTING FLOOR TILE IN THIS ROOM - PREPARE TO RECEIVE NEW
FLOOR FINISH - SEE NEW WORK DRAWINGS
20 EXISTING FLOOR DRAIN TO REMAIN - SEE PLUMBING AND NEW WORK
DRAWINGS
D E M O L I T I O N N O T E S
TYP.
Revisions: Date:
100% Construction/BID Documents 05/01/2020 Addendum #2 09/01/2020
| Sheets |
| AD112 - ENLARGED FIRST FLOOR DEMOLITION PLANS |
File details come from the government source that posted it. Updated .