AE-410 - EXTERIOR ELEVATIONS - DEDUCT ALTERNATE 2.pdf
PDF 1 MB Posted
- Solicitation number
- 36C25020B0030
About this file
This pre-solicitation notice is for a new MRI site preparation project at the Dayton VA Medical Center in Dayton, Ohio. The Department of Veterans Affairs Network Contracting Office 10 is seeking a Service-Disabled Veteran-Owned Small Business to provide all labor, materials, supervision, and equipment for site preparation requiring demolition, excavation, grading, and utilities work according to project drawings and specifications. The performance period is 245 calendar days from notice to proceed. The solicitation will be posted on March 20, 2020 on FBO.gov with proposals due approximately 30 days later. The North American Industry Classification code is 236220 for new commercial and institutional building construction with a small business size standard of $39.5 million. The selected SDVOSB must perform a minimum of 15% of construction work. Bid, payment and performance bonds will be required, and a site visit will be scheduled.
View the file
Other files
Show all 25
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
TOP OF MANUF. STONE
18' - 0"
EXISTING FIRST FLOOR
0"
6.29.7 8.8 7.9 6.46.97.3
MANUFACTURED
STONE VENEER
NEW STOREFRONT
SYSTEM
METAL PANEL
COLUMN COVER
EXISTING
STOREFRONT TO
REMAIN
C.J. C.J.
TOP OF STEEL (LOW SIDE)
15' - 3 1/2"
OVERFLOW
DOWNSPOUT WITH
REMOVABLE
SCREEN
OVERFLOW
DOWNSPOUT WITH
REMOVABLE
SCREEN
A A A
OVERFLOW
DOWNSPOUT WITH
REMOVABLE
SCREEN
RE-USED LIGHT
BOLLARD (TYP.)
RE-USED LIGHT
BOLLARD (TYP.)
EXTERIOR LIGHT FIXTURE,
REFER TO ELECT. DWGS
TOP OF MANUF. STONE
18' - 0"
EXISTING FIRST FLOOR
0"
P.5 S.1P.81 P.9 Q.4
MANUFACTURED
STONE VENEER
EXISTING EXTERIOR
WALL TO REMAIN
EXISTING
STOREFRONT TO
REMAIN
NEW STOREFRONT
SYSTEM
METAL PANEL
COLUMN COVER
TOP OF STEEL (LOW SIDE)
15' - 3 1/2"
C.J.
EXISTING STOREFRONT
WINDOW SYSTEM BEYOND
CANOPY
SKYLIGHTS
BOLLARDS, REUSED
EXISTING BUILDING NEW CONSTRUCTION
EXTERIOR LIGHT
FIXTURE, REFER
TO ELECT. DWGS
KNOCK-OUT PANEL
SHADED AREA INDICATING
STONE VENEER PANELS WITH
REMOVABLE CHANNELS
8'-0"
10'-0"
MICHAEL DWAYNE
LIEZERT
S
TATE OF OHIO
R E
G
ISTERED ARCHIT
E C
T9939
Project Number
Office of Construction and Facilities Management
Building Number
Drawing Number
VA FORM 08-6231
CONSULTANTS: ARCHITECTS/ENGINEERS: ARCHITECTURAL PROJECT #
VA Building th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
F
E
D
C
B
A
F
E
D
C
B
A
987654321
987654321
Project Title
Location
Date Checked Drawn
Drawing Title
Approved: Project Director
7850 Freeway Circle
440.243.2000 t
Cleveland, OH 44130
440.243.3305 f
KEY PLAN
Dwg. of
FULLY SPRINKLERED
PHILIP P. KIRK
CHIEF ENGINEER
:2 :5
A M
C U s e rs jc h o D o c u m e n ts R
N E W
M R I S
IT
E
P R E P C e n tr a l_ jc h o .r v t
EXTERIOR ELEVATIONS - DEDUCT
ALTERNATE #2
AE-410
BH Designer
552-CSI-176
NEW MRI SITE PREP
02/21/2020
4100 WEST THIRD STREET, DAYTON, OHIO 45428
18106
BID & CONSTRUCTION
SCALE: 1/4" = 1'-0"AE-410
1 EXTERIOR ELEVATION EAST - DEDUCT ALTERNATE #2
SCALE: 1/4" = 1'-0"AE-410
2 EXTERIOR ELEVATION SOUTH - DEDUCT ALTERNATE #2
Revisions Date
95% CD SUBMISSION 10/07/2019
BID & CONSTRUCTION 12/19/2019
CAM REVIEW 02/21/2020
ADDENDUM #1 06/08/2020
| Sheets |
| AE-401 - EXTERIOR ELEVATIONS |
| AE-410 - EXTERIOR ELEVATIONS - DEDUCT ALTERNATE #2 |
| AE-411 - EXTERIOR ELEVATIONS - DEDUCT ALTERNATE #3 |
| AE-511 - DETAILS |
| AE-800 - INTERIOR ELEVATIONS |
| AE-1001 - DOOR & WINDOW SCHEDULES AND DETAILS |