AE-1001 - DOOR AND WINDOW SCHEDULES AND DETAILS.pdf

PDF 420 KB Posted

Attached to
Y1DB--552-CSI-176: New MRI Site Prep (VA-20-00027715)
Solicitation number
36C25020B0030
Issued by

About this file

This pre-solicitation notice seeks proposals for a new MRI site preparation project at the Dayton VA Medical Center. The contractor shall provide all labor, supervision, materials and equipment to professionally prepare the site for a new building to house MRI equipment as required by the drawings and specifications. The performance period is 245 calendar days from notice to proceed. Work will be conducted at the Dayton VA Medical Center located at 4100 West Third Street, Dayton, OH 45428, in accordance with the statement of work, specifications and drawings. Coordination is required with the VA contracting officer and contracting officer's representative.

The solicitation documents will be posted on March 20, 2020, with proposals due approximately 30 days later. This is a 100% set-aside for service-disabled veteran-owned small businesses, which must be registered and verified in various websites. The project value is between $2-5 million under NAICS code 236220 with a small business size standard of $39.5 million. The SDVOSB contractor must perform a minimum of 15% of construction work. Bid, payment and performance bonds are required. A site visit will be scheduled. Questions may be emailed by the deadline.

View the file

Other files

Show all 25

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

FRAME TYPE 1

FRAME WIDTH

SEE SCHED. FOR

2"

1/2" 1/2"

/8

2"

/8

APPLIED STOP

FOR GLAZING

MAY OCCUR

SEE PART. TYPES

WALL THICK.

SEALANT ALL SIDES,

TYP.

SCHEDULED

PARTITION

HEAD DETAIL 1

METAL STUDS AT 12"

O.C. ABOVE HEAD

ONLY

SEE SCHEDULE FOR

FRAME WIDTH AND TYPE

SEE PART. TYPES

WALL THICK.

SEALANT ALL SIDES,

TYP.

SCHEDULED

PARTITION

METAL STUDS AT 12"

O.C. ABOVE HEAD

ONLY

SEE SCHEDULE FOR

FRAME WIDTH AND TYPE

JAMB DETAIL 1

U.O.N.

4"

DOOR ELEV. 'A' DOOR ELEV. 'B' DOOR ELEV. 'C' DOOR ELEV. 'E'DOOR ELEV. 'D'

S E

E S

C H

E D

U L E

2"

SCHED.

SEE 2"

S E

E S

C H

E D

U L E

/4

FRAME ELEV. 'A'

1 3/4"

SCHED.

SEE 1 3/4"

FRAME ELEV. 'B'

ALUM.

FRAME

S E

E S

C H

E D

U L E

H E

IG

H

T

WIDTH

SPANDRAL GLASS

VISION GLASS

RF SHIELD

WINDOW

WINDOW ELEVATION 'A' WINDOW ELEVATION 'B'

H E

IG

H

T

WIDTH

TYPES

SEE PARTITION

RF FRAME

RF GASKET

RF GASKET

/8

REFER TO DETAIL 6/AE-511 FOR

RF FLOORING INFORMATION

RF DOOR SILL PER SHIELDING

MANUFACTURER'S RECOMMENDATION

/8

" USE PLASTIC

ANCHORS AND

DIELECTRIC UNDER

RF SILL, TYP.

PATIENT SIDE

MICHAEL DWAYNE

LIEZERT

S

TATE OF OHIO

R E

G

ISTERED ARCHIT

E C

T9939

Project Number

Office of Construction and Facilities Management

Building Number

Drawing Number

VA FORM 08-6231

CONSULTANTS: ARCHITECTS/ENGINEERS: ARCHITECTURAL PROJECT #

VA Building th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t

F

E

D

C

B

A

F

E

D

C

B

A

987654321

987654321

Project Title

Location

Date Checked Drawn

Drawing Title

Approved: Project Director

7850 Freeway Circle

440.243.2000 t

Cleveland, OH 44130

440.243.3305 f

KEY PLAN

Dwg. of

FULLY SPRINKLERED

PHILIP P. KIRK

CHIEF ENGINEER

:2 :5

A M

C U s e rs jc h o D o c u m e n ts R

N E W

M R I S

IT

E

P R E P C e n tr a l_ jc h o .r v t

DOOR & WINDOW SCHEDULES AND DETAILS

AE-1001

BH Designer

552-CSI-176

NEW MRI SITE PREP

02/21/2020

4100 WEST THIRD STREET, DAYTON, OHIO 45428

18106

BID & CONSTRUCTION

DOOR FRAMES

DOOR HEADS DOOR JAMB

DOOR LOCATION

DOOR ELEVATIONS DOOR FRAME ELEVATIONS

DOOR SCHEDULE

OPENING

NUMBER

OPENING DOOR FRAME DETAILS

U.L. LABEL SHIELD HDWE. SET NOTESWIDTH HEIGHT MAT. THICK. ELEV. GLASS MAT. WIDTH ELEV. TYPE HEAD JAMB SILL

01 First Floor

A100A 7'-11 1/32" 8'-11 3/8" ALUM 1 3/4" E TG-1 ALUM B 1 HD-1 JD-1 1 ALUMINUM AUTOMATIC SLIDING STOREFRONT DOOR

A100B 7'-0" 7'-0" ALUM 1 3/4" D TG-1 ALUM 5 7/8" B 1 HD-1 JD-1 1 ALUMINUM AUTOMATIC SWING STOREFRONT DOOR

A102A 8'-0" 7'-0" HM 1 3/4" C - HM 5 7/8" A 1 HD-1 JD-1 20 MIN 2

A105A 4'-0" 7'-0" HM 1 3/4" A - HM 5 7/8" A 1 HD-1 JD-1 20 MIN 3

A106A 4'-0" 7'-0" WD 1 3/4" A - HM 5 7/8" A 1 HD-1 JD-1 4

A107A 4'-0" 7'-0" WD 1 3/4" A - HM 5 7/8" A 1 HD-1 JD-1 4

A108A 3'-0" 7'-0" WD 1 3/4" - HM 5 7/8" HD-1 JD-1 5

A109A 3'-0" 7'-0" B TG-1 HD-1 JD-1 10 ALUMINUM SWING STOREFRONT DOOR

A110A 4'-0" 7'-0" HM 1 3/4" A - HM 5 7/8" A 1 HD-1 JD-1 6

A110B 4'-0" 7'-0" HM 1 3/4" A - HM 5 7/8" A 1 HD-1 JD-1 7

A111A 4'-0" 7'-0" 1 3/4" A - 1' - 1 3/16" A 1 -- -- RF SHIELD 8 RF SHIELDED DOOR, COORDINATE WITH MRI MANUFACTURER, REFER

TO MRI DETAIL 1 BELOW

A112A 4'-0" 7'-0" WD 1 3/4" A - HM 5 7/8" A 1 HD-1 JD-1 9

A113A 4'-0" 7'-0" WD 1 3/4" A - HM 5 7/8" A 1 HD-1 JD-1 4

WINDOW SCHEDULE

Type Mark

OPENING FRAME DETAILS

U.L. LABEL SHIELD NOTESWIDTH HEIGHT MAT. WIDTH ELEV. TYPE HEAD JAMB SILL

B 5' - 6" 4' - 0" 5" B 1 -- -- -- RF SHEILD RF SHIELDED VIEWING WINDOW BY RF SHIELDING

MANUFACTURER

A 1' - 7" 5' - 7" ALUM 4 1/2"

A 1' - 7" 5' - 7" ALUM 5"

A 1' - 7" 5' - 7" ALUM 5"

WINDOW ELEVATION TYPE

SCALE: 3" = 1'-0"AE-1001

1 MRI DOOR HEADER / SILL DETAIL

Revisions Date

65% DD SUBMISSION 07/29/2019

95% CD SUBMISSION 10/07/2019

BID & CONSTRUCTION 12/19/2019

CAM REVIEW 02/21/2020

ADDENDUM #1 06/08/2020

Sheets
AE-401 - EXTERIOR ELEVATIONS
AE-410 - EXTERIOR ELEVATIONS - DEDUCT ALTERNATE #2
AE-411 - EXTERIOR ELEVATIONS - DEDUCT ALTERNATE #3
AE-511 - DETAILS
AE-800 - INTERIOR ELEVATIONS
AE-1001 - DOOR & WINDOW SCHEDULES AND DETAILS

File details come from the government source that posted it. Updated .