ATTACHMENT - VOLUME 9A_Plumbing Updated 07.11.13.pdf

PDF 286 KB Posted

Attached to
Y1DZ--PROJECT 675-23-100, Bid-Build (BB) Renovate Lake Nona Building 2 for Emergency Department and Observation Unit
Solicitation number
36C24825R0025
Issued by

About this file

This file is a plumbing plan drawing for a new VA hospital project located in Orlando, Florida. The drawing details plumbing specifications for Hospital/Clinic Level 1, Area D, including secondary roof drainage systems, water supply lines, floor drains, and piping routes for various medical spaces such as imaging rooms, MRI areas, nuclear medicine departments, and patient care zones. The document includes technical annotations for pipe sizes, routing, and connections, with specific reference to zones like H-PL1.1FD4-A and includes scale measurements, graphic scales, and a key plan layout.

The related federal contract opportunity (Solicitation Number: 36C24825R0025) is for renovating the Lake Nona Building 2 Emergency Department and Observation Unit, with a total project value between $5-10 million. Key details include a mandatory site visit on February 12, 2025, a SDVOSB (Service-Disabled Veteran-Owned Small Business) set-aside, Davis-Bacon wage requirements, and a technical proposal evaluation process focusing on specialized experience, project management approach, and past performance. Proposals are due electronically to the Contracting Officer Elizabeth Romero, with contractors required to perform at least 15% of work with their own employees and maintain an Experience Modification Rate (EMR) of 1.0 or less.

View the file

Other files

File Type Posted
ATTACHMENT - MEP.pdf PDF
ATTACHMENT - RFI 39.pdf PDF
ATTACHMENT - VOLUME 11C_Lighting Plans Updated 07.08.13-3.pdf PDF
ATTACHMENT - RFI 38.pdf PDF
ATTACHMENT - VOLUME 2C_Arch Construction Plans Updated 05.30.13-2.pdf PDF
ATTACHMENT - VOLUME 7A_Ductwork Updated 07.23.13.pdf PDF
ATTACHMENT - HVAC.pdf PDF
ATTACHMENT - RFI 61.pdf PDF
ATTACHMENT - Site Visit Sign-in Sheet.pdf PDF
ATTACHMENT - Sirca Examination Light.pdf PDF
ATTACHMENT - RFI 108_PL702 Plumbing Details and Schedule.pdf PDF
ATTACHMENT - G2022-10000717-001-001_Diamond_Pledge_NDL_Roof_Guarantee.pdf PDF
ATTACHMENT - VOLUME 11C_Lighting Plans Updated 07.08.13-2.pdf PDF
ATTACHMENT - VOLUME 9A_Plumbing Updated 07.11.13-3.pdf PDF
ATTACHMENT - VOLUME 12A_Power Updated 07.25.13-2.pdf PDF
ATTACHMENT - RFI 11 and 21_Sirca Exam Light Brochure.pdf PDF
ATTACHMENT - RFI 73.pdf PDF
ATTACHMENT - VOLUME 9A_Plumbing Updated 07.11.13-2.pdf PDF
S06 Amendment 36C24825R0025 0001.pdf PDF
ATTACHMENT - Emergency Department Lake Nona Addendum 1.pdf PDF
ATTACHMENT - VOLUME 7A_Ductwork Updated 07.23.13-2.pdf PDF
ATTACHMENT - RFI 58 and 87 - 65 Percent Design Development CIH Report.pdf PDF
Solicitation 36C24825R0025.pdf PDF
ATTACHMENT 6 - Experience Information Sheet.pdf PDF
ATTACHMENT 8 - Past Performance Questionnaire.docx DOCX document
ATTACHMENT 7 - Limitation of Subcontracting Certificate.docx DOCX document
ATTACHMENT 4 - Contract Progress Schedule.docx DOCX document
ATTACHMENT 1 - Construction Specifications.pdf PDF
ATTACHMENT 2 - Construction Drawings.pdf PDF
ATTACHMENT 9 - Base Offer Price Breakdown.xlsx XLSX spreadsheet
ATTACHMENT 3 - DBA Wage Determination 01.24.2025.pdf PDF
ATTACHMENT 5 - EMR.pdf PDF
Show all 32

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

PM

C

PM

C

15" SECONDARY

ROOF DRIANAGE.

24" ABOVE

FINISHED GRADE

(39170 S.F.)

15" RW UP &

DN (39170 S.F.)

8" RW UP &

DN (9705 S.F.)

15" SRW UP

(39170 S.F.)

P-528

P-528

P-528

P-401

P-528

P-401

P-401

P-701 P-401

P-401

P-528B P-505

P-528

P-528

P-528

P-560C

P-401

P-102

P-102

P-102

P-102

FLOOR

C.O.

FLOOR

C.O.

FLOOR

C.O.

FLOOR

C.O.

P-528

P-528

P-560C

P-803

P-803

6" CD UP & DN

FLOOR C.O.

FLOOR C.O.

2" W UP

& DN

1 1/2" V

UP & DN

1 1/2" V

UP & DN

H -P

L1 .1

FD

5-

A

H -P

L1 .1

FD

4-

A

H -P

L1 .1

FD

5-

A

H -P

L1 .1

FD

4-

A

C.T. (ED)

1E702

IMAGING RM-2

1K505c-2

MRI EQUIP

1E206a

HAC

1A609

WAIT

1M702

BIO MED OFFICE

1M204

NUC MED WAIT

1K510

VEST

1F201

CLEAN SUPPLY

1E604

NURSE

1F212

NURSE

1F214

IV PREP

1E304

STORAGE

1E402

ECG CUBICLE

1F404

ECG: CUBICLE

1F408

ECG CUBICLE

1F406

STRETCHER

HOLD

1E301

RECEPTION

1E305

MRI WAIT

1E501

STAFF PHYSICIAN

1K802

STAFF PHYSICIAN

1K804

STAFF PHYSICIAN

1K806

C.T. (#2)

1E605

C.T.

1E601

NURSE

1F206

NURSE

1F204

NURSE

1F202

NURSE

1F208

NURSE

1F210

CORRIDOR

1MC02

COMPUTER

EQUIPMENT

1E201

CLEAN SUPPLY

1E205

SOILED UTILITY

1E203

PHYSICIAN

1F301

CORRIDOR

1EC07

CONTROL RM

1E603

NURSE

PRACTIONER

1K705

TLT

1E404

DRESS

1E403

DRESS

1E401

CORRIDOR

1EC03

CLEAN SUPPLY

1K203

PATIENT DOSE

1K205

READING/CONSULT

1K502

RECEPTION

1K508

RSO/PHYSICIST

OFFICE

1K504

EXAM RM

1K509

TLT

1K511

PASSAGE

1KC08

CHIEF NUC MED

OFFICE

1K807

PROFESS

NON-PHYSICIAN

1K805

STAFF PHYSICIAN

1K803

CORRIDOR

1EC05

CHEST RM

1M206

COMMON

VIEWING RM

1K801

STAFF TLT

1F402

ENTRY

1K505

THYROID UPTAKE

1K503

TECH WORK

AREA

1K505d

CORRIDOR

1KC05

TLT

1K513

CORRIDOR

1KC06

ELEC

1E610

CORRIDOR

1EC06

CORRIDOR

1KC07

EQUIP

1KC06a

CORRIDOR

1FC02

IMAGING RM

1K505a

IMAGING RM

1K505b

CORRIDOR

1EC04

CRASH CART

1E306

WHEELCHAIR &

STRETCHER

WAITING

1E608

MRI ROOM

1E202

MRI CONTROL

1E302

MRI CONTROL

1E204

CORRIDOR

1EC02

MRI ROOM

1E206

NUC WASTE STOR

1K202

IV PREP

1K214a

PET SIM UPTAKE

1K212

PET UPTAKE

1K210

UPTAKE

1K208

UPTAKE

1K206

CORRIDOR

1KC02

CORRIDOR

1EC01

10" SECONDARY ROOF DRIANAGE. 24"

ABOVE FINISHED GRADE (18616 SF)

3" RW UP & DN (1297 S.F.)

3" V UP & DN

P-806

MOUNT 1'-6" O.C. ABOVE

ASSOCIATED LEVEL.

1" CW DN

1" CW DN

FLOOR C.O.

FLOOR C.O.

FOR EXACT LOCATION

OF 3/4" CW UP TO

YARD HYDRANT FOR

MOBILE MRI VECHICLE

SEE CIVIL DRAWING

WALL C.O.

FD-V

H-PL1.1FE1

H-PL1.1FD4-A

H-PL1.1FE1

H-PL1.1FD4-A

H-PL1.1FD4-A

H-PL1.1FD1

H-PL1.1FD4-A

H-PL1.1FD1

H -P

L1 .1

FE

2-

A

H -P

L1 .1

FE

3738394041

C

D

E

F

G

D.9

D.7

F.4

E.4

C.7

E.6

D.6

40.6 39.440.5

37.2

39.7

H-CRAC-12

H-CRAC-13

H-CRAC-14

FOR EXACT LOCATION

OF 3/4" CW UP TO

YARD HYDRANT FOR

MOBILE MRI VECHICLE

SEE CIVIL DRAWING

FD-C

FD-C

FLOOR

C.O.

ROUTE CONDENSATE

TO FLOOR DRAIN

MAINTAIN 2" AIR GAP

ROUTE

CONDENSATE TO

FLOOR DRAIN

MAINTAIN 2" AIR GAP

FLOOR

CO

N

1/8" = 1'-0" GRAPHIC SCALE

4' 8' 24'16'

A1

C2

KEY PLAN

C1

D3

D4

E2

A2 A3

B1 B2

AREA D, ZONE 4

D2

D5 D6

E1 E3

D1

Drawing Title

Approved: Project Director

Project Title

Date

Location

Checked

Building Number

Project Number

Drawing Number

Drawn

CONSULTANTS: ARCHITECT/ENGINEERS:

OFFICE OF

FACILITIES

MANAGEMENT

on e ei gh th in ch o ne f oo t

B

A

C

D

E

F th re e in ch es o ne f oo t

6"

6" on e an d on e ha lf in ch es o ne f oo t on e in ch o ne f oo t

6" 6" th re e qu ar te rs in ch o ne f oo t on e ha lf in ch o ne f oo t th re e ei gh th s in ch o ne f oo t on e qu ar te r in ch o ne f oo t

VA FORM 08-6231, OCT 1978

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

BUILDING IS FULLY SPRINKLERED

A NEW HOSPITAL FOR

VAMC ORLANDO, FLORIDA

Orlando, Florida

673-950

04 JUNE, 2010

Professional Seals:

EB / RLF

NOTES:

SHEET NOTES:

01 AND 02

4322Dwg. ofGO/PPG

ZONE 4 PLUMBING PLAN

BID ALTERNATE NO. 3

HOSPITAL/CLINIC LEVEL 1, AREA D,

H-PL1.1FD4-A

1. 1" PUMPED CONDENSATE TO PLUMBING DRAIN

LOCATED IN INTERSTITIAL SPACE BY

MECHANICAL.

2. 3/4" COLD WATER SUPPLY TO FLOOR MOUNTED

AIR CONDITIONING UNIT FOR HUMIDIFIERS.

No. Description Date

1 CPR 122 09/16/11

2 CPR 234 02/16/12

3 CPR 236 03/09/12

4 CPR 382 03/15/13

File details come from the government source that posted it. Updated .