This document is a lighting plan drawing for a new hospital project at the Orlando VA Healthcare System, specifically for Building 2 at the Lake Nona location. The drawing details electrical and lighting specifications for Level 1, Area D, Zone 5, including comprehensive lighting layouts for numerous rooms such as medical offices, diagnostic areas, corridors, restrooms, and administrative spaces. The drawing includes specific technical notes about electrical contractor coordination, under-counter lighting requirements, occupancy sensor specifications, and circuitry details for various room types.

The associated federal contract opportunity (Solicitation No. 36C24825R0025) is for renovating the Lake Nona Emergency Department and Observation Unit, with an estimated project value between $5,000,000 and $10,000,000. Key procurement details include a site visit scheduled for February 12, 2025, a SDVOSB (Service-Disabled Veteran-Owned Small Business) set-aside, and a requirement for Davis-Bacon wage determinations. Proposals are due electronically to the Contracting Officer Elizabeth Romero, with evaluation criteria focusing on technical approach, past performance, and price, with technical factors being significantly more important than cost.

View the file

Other files

File Type Posted
ATTACHMENT - MEP.pdf PDF
ATTACHMENT - RFI 39.pdf PDF
ATTACHMENT - VOLUME 11C_Lighting Plans Updated 07.08.13-3.pdf PDF
ATTACHMENT - RFI 38.pdf PDF
ATTACHMENT - VOLUME 2C_Arch Construction Plans Updated 05.30.13-2.pdf PDF
ATTACHMENT - VOLUME 7A_Ductwork Updated 07.23.13.pdf PDF
ATTACHMENT - HVAC.pdf PDF
ATTACHMENT - RFI 61.pdf PDF
ATTACHMENT - Site Visit Sign-in Sheet.pdf PDF
ATTACHMENT - Sirca Examination Light.pdf PDF
ATTACHMENT - RFI 108_PL702 Plumbing Details and Schedule.pdf PDF
ATTACHMENT - G2022-10000717-001-001_Diamond_Pledge_NDL_Roof_Guarantee.pdf PDF
ATTACHMENT - VOLUME 9A_Plumbing Updated 07.11.13-3.pdf PDF
ATTACHMENT - VOLUME 12A_Power Updated 07.25.13-2.pdf PDF
ATTACHMENT - RFI 11 and 21_Sirca Exam Light Brochure.pdf PDF
ATTACHMENT - RFI 73.pdf PDF
ATTACHMENT - VOLUME 9A_Plumbing Updated 07.11.13.pdf PDF
ATTACHMENT - VOLUME 9A_Plumbing Updated 07.11.13-2.pdf PDF
S06 Amendment 36C24825R0025 0001.pdf PDF
ATTACHMENT - Emergency Department Lake Nona Addendum 1.pdf PDF
ATTACHMENT - VOLUME 7A_Ductwork Updated 07.23.13-2.pdf PDF
ATTACHMENT - RFI 58 and 87 - 65 Percent Design Development CIH Report.pdf PDF
Solicitation 36C24825R0025.pdf PDF
ATTACHMENT 6 - Experience Information Sheet.pdf PDF
ATTACHMENT 8 - Past Performance Questionnaire.docx DOCX document
ATTACHMENT 7 - Limitation of Subcontracting Certificate.docx DOCX document
ATTACHMENT 4 - Contract Progress Schedule.docx DOCX document
ATTACHMENT 1 - Construction Specifications.pdf PDF
ATTACHMENT 2 - Construction Drawings.pdf PDF
ATTACHMENT 9 - Base Offer Price Breakdown.xlsx XLSX spreadsheet
ATTACHMENT 3 - DBA Wage Determination 01.24.2025.pdf PDF
ATTACHMENT 5 - EMR.pdf PDF
Show all 32

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

UP

DN

DD

D

D

GENERAL

PURPOSE/X-RAY

ROOM/(RAD

ROOM)

1M103

DIGITAL

ARCHIVE

1M604

TLT

1M302

SOILED HOLD

1M306 CLEAN UTILITY

1M308

CONCESSIONS

1M811

EMPLOYEE

BIO-SAFETY

1M307

RADIOLOGY

LOCKERS AND

TOILETS

1M303

COMM

1M403

OFFICE

(FDVA/STATE)

1N206

OFFICE

(FDVA/STATE)

1N204

OFFICE (VFW)

1N202

OFFICE

(FAVA/STATE)

1N205

OFFICE

(FDVA/STATE)

1N203

RECEP(FDVA/STATE)

1N201

OFFICE (PVA)

1N406

OFFICE (PVA)

1N404

OFFICE/RECEP(PVA)

1N402

OFFICE/ADMIN(DAV)

1N401

OFFICE (DAV)

1N403

OFFICE

1N405

LOCKERS

MALE

1G302a

TLT & SHWR

MALE

1G302b

RETAIL

STORAGE

1G304

TLT & SHWR

FEMALE

1G303b

HAC

1G305

EVIDENCE

STOR

1H206a

OFFICE(COUNTY)

1G101b

OFFICE(COUNTY)

1G101a

POLICE

TRAINING

ROOM

1H206

TRAINING

ROOM

1G408

CO-ORDINATOR

1G406

WAITING

1G404

STORAGE

1G410

OFFICE

1H204

SERVICE

OFFICER

1G401

CHIEF

1G403

OFFICE

1H202

OFFICE

1H203

CLERICAL

1H201

ECG CUBICLE

1F104

STRESS

LAB/ECHO

1F604

STRESS

LAB/ECHO

1F602

STAFF TLT

1F402

TLT

1F403

HAC

1F401

STORAGE

1F101

ECG: CUBICLE

1F408

ECG CUBICLE

1F406

PHYSICIAN

1F303

PHYSICIAN

1F301

PACEMAKER/HOLTER

MONITOR

ROOM

1F307

CHIEF

NON-INVASIVE

1F203

UNASSIGNED

1F309

ECG/ECHO

READING

1F601

ECHO ROOM

1F605

ECG ROOM

1F106

STRESS LAB

1F607

PATIENT

STORAGE

1F716a

RAD/FLOURO

1M708

PACS OFFICE

1M406

ADPAC OFFICE

1M404

BIO MED

OFFICE

1M204

CONFERENCE

1M718

RF TLT

1M712

RF TLT

1M706

CHIEF OF

CARDIOLOGY

1M715

SECRETARY

1M717

GENERAL

PURPOSE/X-RAY

ROOM/(RAD

ROOM)

1M105

TECH WORK

1M210

ELEC

1N601a

CORRIDOR

1MC07

WAIT

1M702

CHEST RM

1M206

CHIEF TECH

OFFICE

1M402

CANTEEN

RETAIL

1N601CORRIDOR

1MC03

PASSAGE

1MC04

CORRIDOR

1MC06

CONTROL

1M103a

COMM

1N601b

CORRIDOR

1NC04

PASSAGE

1NC02

CORRIDOR

1GC03

WAITING/LOUNGE

1G101

STAIR

1ES01

ELEV LOBBY

1GC02

COFFEE SHOP

1F808

WORK

1F808a

CORRIDOR

1FC06

PATIENT REP

1F806

ELEC

1F802

ELEVATOR

LOBBY

1F716

PASSAGE

1HC02

VESTIBULE

1G303

CORRIDOR

1FC04

DETECTIVE

OFFICE

1H410

DRESS

1M714

CORRIDOR

1MC08

SECRETARY

1G402VEST

1F201

PATIENT REP

1F804

PUBLIC TLT

1F808b

CORRIDOR

1MC02

TECH WORK

1M210

CORRIDOR

1FC03

CORRIDOR

1FC05

ELEVATOR

1EE02

ELEVATOR

1EE01

ELEVATOR

1FE03

ELEVATOR

1FE01

CORRIDOR

1FC07

LOCKERS

FEMALE

1G303a

VESTIBULE

1G302

CORRIDOR

1FC08

PHYSICIAN

1F505

PHYSICIAN

1F503

CONTROL

1M206a

HAC

1G304a

OFFICE

1H206b

OFFICE

1H206c

CORRIDOR

1FC02

303136

1.2 8.1

C

D

E

F

G

D.9

30.235.2

D.7

F.4

E.4

C.7

1.4

32333435 A7

7.7

32.532.7

33.6

K.8

K.9 a

D D

D

D

D

D

D

D

D

D

D

D

D

D D D D

D

D

D

D

D

HA2

HA11

HF10

HA1

HA3

HA1

HA3

HA11

HA3

HA3

HA3

HA2

HA2 HA3

HA1

HA2

HF1

HA1

HA3

HA3

HF1

HA3

HA3

HA1

HA3

HA3

HA2

HA3

HA3

HA3

HA3

HA3

HA1

HA3

HA2

HA1

HA3

HA3

HA3

HA3 HA3

HA3

HA11 HA11 HA11

HA11

HA2

HA2

HA2

HA3

HA3 HA3

HA3

HF10

HF10

HA3

HA3

HA3

HA3

HA3

HA3

HA11

HA11

HA1 HA1 HA3

HA3

HA11

HA3 HA3

HA11

HA11HA11 HA11HA11

HA11

HA11 HA11

HA3

HA1HA1

HA1

HB2 HB2 HB2

HB2HB2HB2HB2

HA1 HA1 HA1

HA3 HA3

HA3

HA3 HA3

HA11

HA11

HA3

HA3 HA3

HA11

HA3

HA3

HA3 HA3

HA11

HA3

HA3

HA3

HA11

HA3

HA3

HA3

HA3

HA1 HA1 HA1

HA2

HA2 HA2

HA2

HA2HA1

HB1

HB1

HB1

HA2

HA2

HA2

HA1HA1 HA1

HA2

HA3

HA3

HA3

HA3

HA3

HA3

HA3

HA3

HB2 HB2

HB2 HB2

HB2

HA2

HB2

HA9

HA9

HA1

HA1

HA1

HA1

HA3

HA3

HA3

HA3

HA3

HA3 HA3

HA3

HA3HA3 HA3

HA3

HA3

HA3

HA1 HA1 HA1 HA1 HA1 HA1

HB2

HB2 HB2 HB2

HB2 HB2

HB2

HB2 HB2

HB2 HB2

HB2

HA1 HA1

HA2

HA9 HA9 HA9

HA9

HA9 HA9

HA1

HA1

HA1HA1

HA9

HA9HA9

HA9

HA9

HA3

HA3

HA2

HA2

HA2

HA3HA3HA3

HA9HA9

HA9

HA9

HA9

HA3

HA3HA3HA3 HA3

HA3

HA1HA1HA1

HA9

HB2

HB2

HB2

HA3

HA9 HA9

HB2

HB2

HB2

HB2

HB2

HB2 HB2

HB2

HA9

HA9

HA9

HA9

HA9

HA3

HA3

HA3

HA3

HA3

HA1

HA1

HA3

HA11

HA1

HA3

HA1

HA11

HA3

HA3

HA3

HB1 HB1

HA1 HA1

HA3

HF10 HF10

HA3

HHC

HHC

HW2

HW2

HA2HA2

HA3

HA3

HA1

HA1

HB1

HB1

HW

HB1

HW

HA1

HA1

HA1

HA1

HB1

HW

HA14

HB1 HB1

HU

HU

HU

a a,b a,b a,b a,b a,b a,b a a a a,b a,b a a,b a,b a,ba,b a,b a

HU

HU

a

HF1

HWHW

HB1 HB1 HB1

HA11

HA1 HA1 HA1 HA1

HA1

HA3

HU

HU

HU

HU

HU

HA3

HU

HU HU

a a,b a,b a,b

HU

HU HU

g

HB1

HW

HU

b b b b b bbb a a a a a,b a,b a,b a,b a a a,b a,b a a a,b a,ba,ba,b

HU

a a,b a,b

HU

HU

a a a,b a,ba,ba,ba,b a,b

HB2HB2

HB2

HB2

a,b a,b a a a,b a,b a,b a,ba,b

D a a a,b a,b a,b a,b a,b a,b a,b a,b a,b a,b a,b a,b a,b a,b a,b a,b a,b a,b a,b a,b a,b a,b a,b a,b a,ba,b a,b a,b a a a a a a a a a a a a a a a,ba,b a,b a,b aa,b a,b a a,b a,b a,b a,b a a a a,ba,b a,b a,b a,b a,b a a a,b a,b a,b a,b a a,b a,b a,b a,b a a,ba,b a,b a,b a,b a,ba,b

HA3

HA3

b c c cc c a,b a,b c c

D

HB1

HB1

HB1

HW

HW

HF1

HF1

HF2

HF3

a

HB1

HW

DD

H1D5HN1- 2

H1D5HN1- 3

HB1

H1D6HN2- 4

a,b a,b a,b a a,ba,b a,b a,b a,b b b b b ee ff ff f ff a a aa a a a a c c c c

D Df aDc3e 3b

D b

HB2 b bb

HB1

b b b

HB1

b b b b bb b

HB1

b

HB1

b b b b b b b b b b a b b b b b b b bb b b b b b

HB1

b b b

HW

b

H1D5HN3

b a,b

HE

HB2

D

H1D5HN2- 3

HA1

HA1

H1D5HN2- 1

H1D5HN1- 4

H1D5HN1- 1

H1D5HN1- 6

H1D5HN2- 4 H1D5HN2- 9

HF9

HF9HF8

b

HA3

HUHW

HA9HA9HA9HA9

HA9

HA9HA9HA9HA9

HA9 HA9 HA9

HA9HA9 HA9 HA9

HA9 HA9

HA9 HA9

HA9 HA9

HA9

HA9

HA9 HA9

HA9

HA9HA9

HA9

HA9 HA9 HA9

HA9HA9

HA9 HA9

HA9HA9

HA9

HA9

HA9

HA9

HA9

HA9HA9

HA9

HA9

HA9

HA9HA9

HA9HA9

HA9

HA9

HA9

HA9 HA9

HA9 HA9

HA9HA9

HA9

HA9

HA9

HA9

HA9

HA9 HA9 HA9

HA9

HA9HA9

HA9HA9HA9

HA9

HA9

HA9

HA9 HA9 HA9 HA9

HA9

HA9

HA9

HA9

HA9HA9HA9HA9

D

D D

D

D

D

D

HU

HA9

HA9

H1D5HN3- 1

HA3

a,b

D

HE

D

D D

D

D

D

D

D

D

D

D D

D

D

D D

D D

D

D

HT1

HT2HT2

H1D5HC1- 3

D D

D

D

D D

D

D

D

D

D

D

D

HA2

H1D5HN2- 6

D

HB2

HB2

HA9

a

UP TO 3RD FLOOR CKT.

TYPICAL.

HA9

HT1 HT1 HT1

ZONE KZONE I

ZONE G,H

ZONE J

ZONE E,F

DOWN

UP

UP

UP

DOWN

DOWN

HW2

HP

HP

D b D a a a a a b b b b b b b b b b a a a a a

U

HT3

HT3

2 3

D

D

D a

D

D

D

H1D5HC1- 1

HB1 HB1

HB1

H1D5HC1- 2

D

H1D5HN2- 7

U

HU

HU

D D

HE

HA9HA9HA9

HA9 HA9

HA9

HA9

HA9 HA9

HE

HE

HA2

HA1

HA2

HF10

HF10

HF10 HF10

HA11

HA1

HE

HA1HA1

HA1

HA1

HE

HE

HA1

HA1HA1

HA1 HA1 HA1 HA1

HA1

HA1

HA1

HA1

HA1

HA1

HA1

HA11

HA11HA11

HA11

HA3

HA3

HE

HA3

HE

HA11

HE

HE

HE

H1E2HS1-2

HB16 HB16

HE

H1E2HS2-2

HB1

HB1

HA11

HA11

HE

HE

HE

HB1

HE

HB1

HA11

HA11

HE

HE

HE

HA1

H1E2HS2-7

HE

H1E2HS2-9

HE

HE

HE

HB5

HB5

HB1 HB1

HB1 HB1

HB1HB1

HB1 HB1

HB1 HB1

HE

HB19 HB19HB19

HB19 HB19 HB19 HB19 HB19 HB19 HB19 HB19 HB19 HB19 HB19 HB19 HB19

HB19HB19HB19HB19HB19HB19HB19HB19HB19HB19HB19HB19HB19

HB1

HB1

H1E2HN1-10

HB6

HT2 HT2HT2HT2

HT1

HT2

HT2

HU HU

HU

HU g g

HP

HP

HUHU

HB2

HB2

HU

HU

HU

HF1 HF1

HB1

HU

HU

HU

HB2

HU

a,b b b b b b b

3 3 a a a bb b

D a bbb b

D

HU HUc c c c c c a a a a a a a a a a a a a 1 b b

HU

d d d d d d e e e a,b ccc b b bb a a a a a a aa a a a a aa b b a,b c c c b a a c c c cc a,b a,b a a a a e e e e e d d d d d b b b b b b b b a a a a a,b D f d d f f f f gHU HU HU a b c c a,b b b b b a a

HA9

HA9

HA9

d

HA2

HA2

U a a a

U

U

U

U

U

U b

U

U

U

U

U

U

U

UU

HB6

HU

d

H B

HB2

HB2

HB2

H B

HB2

HB2

HB2

HB2

HA9

HA9

HA9

HA9

HB2

HB2

b b b b a a a c a a a a aaa a3b cDD

D

D c c c c c

HE

RAD/FLOURO

1M710

CONTROL

1M710a

MAIL ROOM

1C112a

HA3

a,b

HA3

a,b

HA3

a,b

D

D a b a b

HA3

a,b

HB1 HB1

HA1

a

HF10

16D

16D

HB2

HB2

a

3e

3b 3b d

HU

d

HB2 a

HB2

a

D

Drawing Title

Approved: Project Director

Project Title

Date

Location

Checked

Building Number

Project Number

Drawing Number

Drawn

Dwg.

CONSULTANTS: ARCHITECT/ENGINEERS:

OFFICE OF

FACILITIES

MANAGEMENT

on e ei gh th in ch o ne fo ot

B

A

C

D

E

F th re e in ch es o ne fo ot

6"

6" on e an d on e ha lf in ch es o ne fo ot on e in ch o ne fo ot

6" 6" th re e qu ar te rs in ch o ne fo ot on e ha lf in ch o ne fo ot th re e ei gh th s in ch o ne fo ot on e qu ar te r in ch o ne fo ot

VA FORM 08-6231, OCT 1978

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

A NEW HOSPITAL FOR

VAMC ORLANDO, FLORIDA

Orlando, Florida

673-950Professional Seals:

EB / RLF of04 JUNE, 2010

BUILDING IS FULLY SPRINKLERED

01 AND 02

HOSPITAL/CLINIC

H-EL1.1FD5-A

LEVEL 1, AREA D, ZONE 5

LIGHTING PLAN BID ALTERNATE NO. 1

EB/RLF 3662

N

1/8" = 1'-0" GRAPHIC SCALE

4' 8' 24'16'

A1

C2

KEY PLAN

AREA D, ZONE 5

C1

D3

D4

E2

A2 A3

B1 B2

D2

D5 D6

E1 E3

D1

D7

CLINIC

HOSPITAL

P-W P-E

A4

E4

W

KEY NOTES:

H -E

L1 .1

FD

5-

A

H -E

L1 .1

FD

H-EL1.1FE2-A

H-EL1.1FD5-A

No. Description Date

4 CPR 122 09/16/2011

5 CPR 178 11/07/2011

6 CPR 219 01/16/2012

7 CPR 236 03/09/2012

8 CPR 272 04/30/2012

9 CPR 319 08/02/2012

10 CPR 323 08/16/2012

11 CPR 373 01/24/2013

GENERAL NOTES:

1. ELECTRICAL CONTRACTOR SHALL COORDINATE CEILING TYPE WITH FIXTURE FLANGE OR GRID TYPE

MOUNTING PRIOR TO INSTALLATION.

2. ALL UNDER COUNTER LIGHTING FIXTURES SHALL BE CIRCUITED TO NEAREST RECEPTACLE. A WALL SWITCH SHALL BE INSTALLED TO CONTROL UNDER CABINET LIGHTING FIXTURES. WHERE TWO OR MORE UNDER CABINET LIGHTING FIXTURES, TYPE "HU", SHALL BE CIRCUITED TO THE SAME CIRCUIT AND CONTROLLED BY THE SAME WALL SWITCH. MOUNTING LOCATION OF FIXTURES SHALL BE AT CENTER OF

CABINETS.

3. LIFE SAFETY LIGHTING SHALL BE CONTROLLED BY CIRCUIT BREAKER IN LIFE SAFETY PANEL EXCEPT

WHERE INDICATED ON THE DRAWING.

4. OCCUPANCY SENSOR IN OFFICE SHALL BE THE DUAL TECHNOLOGY TYPE WITH THE 20'x20' PATTERN (OR DESCRIPTION 3), UNLESS OFFICE IS LARGER THAN 20'x20'.

5. ALL HOME RUNS SHALL BE ROUTED FROM THE DEVICE/FIXTURE INDICATED TO THE APPROPRIATE WIREWAY WITHIN THE INTERSTITIAL SPACE ABOVE. SEE 1/H-EP5.510 FOR INTERSTITIAL FLOOR

PENETRATION DETAIL.

6. CORRIDOR OCCUPANCY SENSORS SHALL BE THE ' ULTRASONIC ' TYPE WHEN SPACE MORE THAN 40' APART. ALL CORRIDOR FIXTURES OF NORMAL CIRCUITRY SHALL BE CONTROLLED BY OCCUPANCY

SENSOR LOCATED IN SAME CORRIDOR, UNLESS OTHERWISE INDICATED BY SWITCH LEGS.

7. CIRCUIT ALL IN-USE LIGHT "HN2" TO 120V CIRCUIT SERVING THE RESPECTIVE IMAGING SUITE AND CIRCUIT PER IMAGING EQUIPMENT MANUFACTURERS RECOMMENDATIONS. (CIRCUIT FROM RADIOLOGY EQUIPMENT)

1 1

H -E

L1 .1

FD

H -E

L1 .1

FD

5-

A1

8. THIS BID ALTERNATE DRAWING SHALL REPLACED THE BASE BID DRAWING H-EL1.1FD5. REMOVE

DRAWING H-EL1.1FD5 FROM THE DRAWING SET.

1 NOT USED.

2 COORDINATE MOUNTING HEIGHT OF THE "HHC" FIXTURE WITH ARCHITECT.

3 DIMMER CONTROL FOR DIMMING SYSTEM CONTROLLING LIGHTING IN THIS

ROOM.

4 SEE POWER DRAWING H-EP1.1FD5 FOR THE CONNECTION OF PIT LIGHT.

5 INVERTER FOR WALL MOUNTED HID FIXTURES. INVERTER SHALL BE 3.0 KVA,

277V, SINGLE PHASE UNIT. TRANSFER TIME SUFFICIENT FOR HID LAMPS

REMAIN ILLUMINATED THROUGH THE TRANSFER. BATTERY TIME SHALL BE FOR

A MINIMUM OF 10 MINUTES.

6 NORMAL LIGHTING CIRCUIT SHALL BE CONTROLLED BY THE LIGHTING

CONTROL SYSTEM LOCATED IN ROOM 1B201a. SEE DRAWING H-EL6.001 DETAIL

# 7 FOR LIGHTING CONTROL DETAIL.

7 NOT USED.

8 CIRCUIT TO 120/208V PANEL H2D2LN2 CIRCUIT #19,21 LOCATED IN ELECTRICAL

ROOM 2N506.

9 20A, 3P CIRCUIT (5250W) TO 120/208V PANEL H1D5LN1 CIRCUIT #44,46,48.

10 DIMMER PANEL TO SERVE CANTEEN RETAIL ROOM 1N601. SEE LIGHTING

MATRIX ON DRAWING.

11 20A, 1P CIRCUIT (4437W) TO PANEL H1D5HN2 CIRCUIT # 7.

12 NOT USED.

13 SEE SHEET H-EL1.1FE2-A FOR CONTINUATION.

14 (2) 20A, 120/277V SINGLE POLE SWITCHES MOUNTED IN DEMOUNTABLE

PARTITION. MOUNT AT 48" AFF TO CENTER. COORDINATE WITH

MANUFACTURERS REQUIREMENTS FOR BACKBOX AND RACEWAY.

15 SEE TYPICAL CONFERENCE ROOM AUDIO/VISUAL RISER DIAGRAM DETAIL

2/H-ET5.505 FOR LIGHTING CONTROLS IN THIS AREA.

16 PROVIDE TWO WALL MOUNTED DIMMING SWITCHES FOR CONTROL OF THE

LIGHTING FIXTURES IN THIS ROOM IN THE EVENT THAT THE AUDIO/VISUAL

CONTROL SYSTEM IS NOT PROVIDED. COORDINATE WITH THE RESIDENT

ENGINEER. THE SWITCHES SHALL BE MOUNTED IN THE BOX ADJACENT TO THE

DOOR DESIGNATED FOR THE THE LOW VOLTAGE DIMMING CONTROLS.

17 SEE TYPICAL CONFERENCE ROOM AUDIO/VISUAL RISER DIAGRAM DETAIL

1/H-ET5.505 FOR LIGHTING CONTROLS IN THIS AREA.

File details come from the government source that posted it. Updated .