01 - Floor Plan Penthouse Drawings.pdf
PDF 322 KB Posted
- Attached to
- Y1DA--FY24: NRM (PROJ: 673-23-104) DB Install Fall Protection Anchorage and Guardrails for Bldg 1 and 2
- Solicitation number
- 36C24824R0016
About this file
This document contains floor plan drawings for penthouse renovations and the related federal contract opportunity for fall protection installations. The floor plan drawings depict the layout and construction details for renovating the penthouse area, including new wall installations, door locations, roof drainage features, and mechanical equipment placements. The related federal contract opportunity is seeking offers to install fall protection anchorage and guardrails for Buildings 1 and 2 of a Veterans Affairs medical facility. Offerors should respond by the listed solicitation number and date. The work will be completed for the Veterans Health Administration under Contract Number 36C24824R0016.
View the file
Other files
Show all 42
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
RJ
RJ
RH.1
RH.1
R1R1
R1.6
R1.9
RH
RH
R2R2
RG
RGRF
RF
RE
RE
RD
RD
RC
RCRB
RB
RA.9
RA.9
RA
RA
R2.5R2.5
R4R4
R3.2
R3R3
R3.4
MECH CHASE
ELEV. EQUIP.
PE02
EQUIPMENT
PA01
STAIRS
S1P
CHASE
PCH02
PLENUM
PA03
R3.3
R2.4
R1.7
RJ.1
RJ.1
11' - 9" 9"
23' - 0" 24' - 0" 24' - 0" 24' - 0" 24' - 0" 23' - 0" 9"
11' - 9" 4"
7'
- 1
1" 2'
- 4
0"
2"
0" 2'
- 1 1"
7'
- 4
3"
0"
2"
3"
EX
S
1P 3'
-0
EX PA03
3' - 0"
EX
P
A0 1B
2' -8
EX
P
A0 1A
3' -0
EX PE02
3' - 0"
A301
A302
04.04
DN
EXISTING
ELEVATOR
EL31
02.37
02.37 02.37
02.37
02.37 02.37
07.29
1/4
SL
OP
E
07.3207.33
07.34
07.35
02.94
07.54
07.56 04.09
04.04
04.0804.08
PA01C
7' - 0"
04.10
18' - 10"
01.20
05.4205.42
1. ALL DIMENSIONS ARE TO FACE OF STUD IN NEW CONSTRUCTION, FACE OF FINISH IN EXISTING.
2. ALL FLOOR FINISH CHANGES OCCUR AT CENTERLINE OF DOOR IN CLOSED POSITION, UNLESS NOTED OTHERWISE.
3. COORDINATE LOCATIONS OF ALL FLOOR AND ROOF DRAINS WITH PLUMBING PLANS.
4. PATCH INTERIOR HOLES IN NON-RATED MASONRY WALLS BY FILLING VOIDS WITH CLOSED CELL SPRAY INSULATION.
PATCH INTERIOR HOLES IN RATED MASONRY WALLS BY REPAIRING CELL WALLS WITH DRY PACK MORTAR. MASONRY WALL PATCHES ARE TO BE FINISHED FLUSH WITH EXISTING BLOCK PRIOR TO APPLYING WATER BARRIER OR FINISH.
NORTH 3/16" = 1'-0"1 FLOOR PLAN - PENTHOUSE FLOOR
04.10 PATCH AND INFILL WALL AROUND NEW DOOR WITH CONCRETE MASONRY BLOCKS
AND BRICK VENEER TO MATCH THE EXISTING ADJACENT PERIMETER WALLS, SEE
STRUCTURAL NOTES FOR REINFORCING
05.42 ROOFTOP EDGE PROTECTION IN COMPLIANCE WITH IBC 1015.6
07.29 OUTSIDE AIR INTAKE TUNNEL PLENUM
07.32 EPDM OVER TAPERED RIGID INSULATION OVER METAL DECKING
07.33 PARAPET CAP, SEE DETAIL ON A501
07.34 REPAIR DAMAGED ROOFING
07.35 REMOVE LOUVER AND INFILL WALL TO MATCH EXISTING
07.54 NEW THROUGH WALL ROOF SCUPPER
07.56 SEE MECHANICAL DRAWINGS FOR LOUVER REPLACEMENT
01.20 10 FOOT PERIMETER LINE AROUND DOOR ACCESS AREA
02.37 EXISTING ROOF DRAIN TO REMAIN
02.94 REMOVE EXISTING 4" CONCRETE CURB AND LEVEL FLOOR
04.04 NEW WALL INFILL TO MATCH EXISTING WALL, SEE STRUCTURAL NOTES FOR
REINFORCING
04.08 REMOVE EXISTING METAL WALL AND INFILL OPENING WITH CONCRETE MASONRY
UNITS AND BRICK VENEER TO MATCH THE EXISTING PENTHOUSE PERIMETER. FILL
UNGROUTED MASONRY CELLS WITH EXPANDED PERLITE CONSTRUCTION FILLER,
SEE STRUCTURAL NOTES FOR REINFORCING
04.09 PATCH AND INFILL WALL AROUND NEW LOUVER WITH CONCRETE MASONRY BLOCKS
AND BRICK VENEER TO MATCH THE EXISTING ADJACENT PERIMETER WALLS, SEE
STRUCTURAL NOTES FOR REINFORCING
RAND M.
EARDLEY
128806
ST
OF
AT
E UTAH
ARED CH
IT
EC
T
NS
CE
LI 04 DEC 2020