BLDG 500 Renovate 3A-3B - Drawings 3A Issue for Bid_Part3.pdf

PDF 10 MB Posted

Attached to
Z2DA--Bldg 500 - Renovate 3A and 3B Proj 613-19-100
Solicitation number
36C24521B0008
Issued by

About this file

This document outlines a federal construction contract opportunity for renovations at a Veterans Affairs medical center. The Department of Veterans Affairs is seeking a prime contractor to provide all labor, materials, tools and equipment for a project to renovate buildings 3A and 3B at the VA Medical Center in Martinsburg, West Virginia. The work includes general construction, alterations, necessary removal of existing structures, millwork, permanently mounted equipment and interior finishes. The estimated construction cost range is between $10 million and $20 million. This opportunity is set aside exclusively for Service-Disabled Veteran Owned Small Businesses. Interested contractors must be registered on various federal websites and verified as an SDVOSB. A pre-bid site visit will be held on June 9th and questions about the solicitation are due by June 17th. The solicitation documents will be available on June 3rd and bids are due at a public opening on July 14th. The award is subject to availability of funds.

View the file

Other files

File Type Posted
092216 Non-Structural Metal Framing.pdf PDF
Martinsburg 3B Negative Air Bid Document Missing Spec SUBMITTAL TRANSMITTAL.pdf PDF
099100 Painting.pdf PDF
123600 Countertops.pdf PDF
36C24521B0008 0002.pdf PDF
090600 Schedule for finishes 3B-SV.pdf PDF
123200 Manufactured Wood Casework.pdf PDF
BLDG 500 Renovate 3A 3B - Specs VOL 1 Issue for Bid - REV 07132021.pdf PDF
101400 Signage.pdf PDF
092900 Gypsum Board.pdf PDF
123100 Manufactured Metal Casework.pdf PDF
096513 Resilient Base and Accessories.pdf PDF
117310 Ceiling Mounted ICU Boom 3B - Rev11092020.pdf PDF
613-19-101_Renovate 3A-3B_RFI-Log_21-0812.pdf PDF
BLDG 500 Renovate 3A 3B - Specs VOL 3 Issue for Bid - REV 07132021.pdf PDF
117310 Ceiling Mounted ICU Boom 3A - Rev 02162021.pdf PDF
096516 Resilient Sheet Flooring.pdf PDF
122400 Window Shades.pdf PDF
096519 Resilient Tile Flooring.pdf PDF
093013 Ceramic Porcelain Tiling.pdf PDF
095100 Acoustical Ceilings.pdf PDF
Martinsburg 3A Negative Air Bid Document Missing Spec SUBMITTAL TRANSMITTAL.pdf PDF
36C24521B0008 0001 signed.pdf PDF
BLDG 500 Renovate 3A-3B - Drawings 3A Issue for Bid_Part2.pdf PDF
BLDG 500 Renovate 3A-3B - Drawings 3B Issue for Bid_Part2.pdf PDF
Brand Name Justification 3B.pdf PDF
Security_CompletePacket.pdf PDF
613-19-100 Renovate 3A 3B_ILSM - Copy.pdf PDF
BLDG 500 Renovate 3A-3B - Specs VOL 1 Issue for Bid_.pdf PDF
BLDG 500 Renovate 3A-3B - Drawings 3B Issue for Bid_Part3.pdf PDF
BLDG 500 Renovate 3A-3B - Drawings 3A Issue for Bid_Part1.pdf PDF
613-19-101_Renovate 3B_Patient Lift Installation_Relocation - Copy.pdf PDF
BLDG 500 Renovate 3A-3B - Specs VOL 4 Issue for Bid_.pdf PDF
BLDG 500 Renovate 3A-3B - Drawings 3B Issue for Bid_Part1.pdf PDF
BLDG 500 Renovate 3A-3B - Specs VOL 2 Issue for Bid_.pdf PDF
BLDG 500 Renovate 3A-3B - Specs VOL 3 Issue for Bid_.pdf PDF
36C24521B0008_1.docx DOCX document
36C24521B0008.docx DOCX document
Show all 38

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

OS

OS

OS

OS

J JJ JJ JJ JJ J

J J J J J J J J J J

OS

OS OS

ES501

.OS

.LV .LV

.LV

.OS

.OS

.OS

.OS.OS

.OS

.OS

ICU STORAGE

3A-314

SOILED UTILITY

3A-316 MEDICATION ROOM

3A-320

CLEAN SUPPLIES

3A-318

TOILET ROOM

3A-309

OFFICE

3A-306

STAFF TOILET

3A-315A1

STAFF TOILET

3A-313

STAFF LOUNGE

3A-315E

PATIENT SHOW ER

3A-326

ICU PATIENT ROOM

3A-332

ICU PATIENT ROOM

3A-331

ICU PATIENT ROOM

3A-330

ICU PATIENT ROOM

3A-329

BARIATRIC ISOLATION ROOM

3A-328A

CONFERENCE ROOM

3A-308

TELE. RM.

3A-310

ELEC. RM.

3A-340

ICU TOILET

3A-331A

ICU TOILET

3A-329A

ICU TOILET

3A-319A

ANTE ROOM

3A-328

ISOLATION TOILET

3A-328B

ANTE ROOM

3A-325

ICU TOILET

3A-324A

NOURISHMENT

3A-317

ICU TOILET

3A-332A

ICU TOILET

3A-330A

ISOLATION TOILET

3A-325B

W ORKROOM

3A-305

CONSULT ROOM

3A-304

LINEN ALCOVE

3A-312

ISOLATION ROOM

3A-325A

HAC

3A-311

OFFICE

3A-315A

PHARM. OFFICE

3A-315B

NURSE MANAGER OFFICE

3A-315C

NURSE SUPERVISOR OFFICE

3A-315D

W ORKROOM

3A-315

CORRIDOR

C15

A2

A2

A2

A2

A2

A2

A2

A2 A2

A2

A2

A2

A2

A2A2

A2 A2

D6-20 B1

A2

A2 A2

A2

A2 A2

A2

A2A2A2

A2

A2

D6-20 D6-20

D6-20 D6-20

A2

A2

B1

DS-10

DS-10

F1

F1

F1

X1

X1

X1

X1

P2

A2 A2

D6-20

A2A2

A2A2

D4-15

D4-15

ICU PATIENT ROOM

3A-324

D4-15

D4-15

D4-15 D4-15

D4-15

ICU PATIENT ROOM

3A-330

ICU PATIENT ROOM

3A-329

B1B1B1B1B1

B1B1

B1 B1

B1

B1

B1

B1 B1

B1 B1B1B1

B1B1 B1

B1

B1 B1

B1 B1

B1 B1

B1B1B1 B1 B1

B1B1B1B1B1 B1 B1

P2P2P2 P2P2P2P2

P2P2P2P2P2 P2 P2 P2

ICU PATIENT ROOM

3A-321

D4-15

P2

P2P2

P2

ES501

E2 N2

E2 N2

E2 N2

E2N2E2N2

E2N2 E2N2 E2N2 E2N2 E2N2

TOILET ROOM

3A-307

IT

3A-303

BIOMED

3A-302

(TYP)

L1

(TYP)

L1

(TYP)

L1

(TYP)

L1

(TYP)

L1

(TYP)

L1

X1

A2A2

D6-20

D4-15D4-15

D4-15 D4-15D4-15

X1

D4-15

D4-15

B1

D4-15

D4-15

D4-15

A2A2

.LV

-15LP-3C

-1LP-3A

-2LP-3A

-3LP-3A

-4LP-3A

-1ELP-3A

-2ELP-3A

-3ELP-3A

-3ELP-3A

A2

SL1

SL1

L5

ICU PATIENT ROOM

3A-323

ICU PATIENT ROOM

3A-319

NURSE STATION

3A-322

CORRIDOR

C15

MOBILE X-RAY ALCOVE

3A-327

CORRIDOR

C3

V1

V1

V1

(TYP)

L1

(TYP)

L1

(TYP)

L1

(TYP)

L1

.LV

.LV

.LV

.LV

.LV

.LVD

.LV

.LV

7 9

6.9

A

B

C D

E

F

7.7 8.3

B.6

L15

L15

L15

-1ELP-3C

L16

L16

L16

13100 watertown plank road suite 200 elm grove, wi 53122

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

Nagel Architects + Engineers project number:

BLDG 500 RENOVATE 3A 613-19-100

19025

CMTA CONSULTING ENGINEERS, INC.

10411 MEETING STREET,

PROSPECT, KY 40059

(502)326-3085

VOLUME AC

U s e rs

\b k a rc h e r\

D o c u m e n ts

\V M

W V

-0 -E

-R b k a rc h e rR U

V A

B .r v t

/5

/2

:2

:4

P

M

ES201

THIRD FLOOR PLAN - 3A, LIGHTING

510 BUTLER AVENUE MARTINSBURG, WV 25405

04/07/2021 PDY BBK

BID DOCUMENTS

FULLY

SPRINKLERED

GENERAL NOTES (LIGHTING):

A. REFER TO THE ARCHITECT'S REFLECTED CEILING PLANS, ELEVATIONS,

AND CASEW ORK DETAILS FOR EXACT LOCATIONS OF ALL W ALL AND

CEILING MOUNTED ELECTRICAL DEVICES.

B. CONTRACTOR SHALL FOLLOW BRANCH CIRCUITING LAY-OUT, AS

INDICATED ON THE FLOOR PLANS, W ITH A MAXIMUM OF THREE (3)

BRANCH CIRCUITS PER HOMERUN. EACH BRANCH CIRCUIT SHALL BE

PROVIDED W ITH A DEDICATED NEUTRAL CONDUCTOR. DEDICATED

NEUTRAL CONDUCTORS SHALL BE CONSIDERED CURRENT

CARRYING. IF ADDITIONAL CONDUCTORS ARE RAN IN THE SAME

CONDUIT W ITH THOSE INDICATED, CONTRACTOR SHALL DERATE ALL

CURRENT CARRYING CONDUCTORS PER N.E.C. #310.15(B)(3), AND

UPSIZE CONDUIT AS REQUIRED PER N.E.C. #300.17 AND ANNEX

C. MULTIW IRE BRANCH CIRCUITS AS DEFINED IN N.E.C #100 / 210.4

(CIRCUITS SHARING A COMMON NEUTRAL CONDUCTOR) SHALL NOT BE

PERMITTED.

C. ALL DEVICE COVERPLATES SHALL BE #302 STAINLESS STEEL. IDENTIFY

THE PANEL AND CIRCUIT NUMBER FOR ALL RECEPTACLES, SW ITCHES,

ETC. IN AREA OF CONSTRUCTION. PROVIDE CLEAR ADHESIVE LABELS

W ITH BLACK LETTERING. IN HEALTHCARE FACILITIES, ENGRAVE

EMERGENCY DEVICE COVERPLATES IN PATIENT CARE AREAS. ALSO,

MARK INSIDES OF ALL DEVICE BOXES W ITH PANEL AND CIRCUIT

NUMBER.

D. LOCATE CHAIN-HUNG INDUSTRIAL FIXTURES IN MECHANICAL ROOMS TO

AVOID DUCTW ORK AND PIPING, TO MAXIMIZE AVAILABLE LIGHT. SPACE

AROUND EQUIPMENT, AIR HANDLERS, ETC. TO PROVIDE ADEQUATE

LIGHTING TO ALL AREAS OF ROOM. PROVIDE ADDITIONAL FIXTURES OF

SAME TYPE AS NEEDED TO FULFILL THIS REQUIREMENT.

E. LOCATE EXIT SIGNS FOR MAXIMUM VIEW ING AREA TO IDENTIFY EGRESS

PATHS AS INDICATED ON PLANS. COORDINATE LOCATIONS SUCH THAT

ARCHITECTURAL FEATURES OR EQUIPMENT FROM OTHER TRADES DO

NOT OBSTRUCT VIEW .

F. W HERE EXIT SIGNS OR EMERGENCY BATTERY PACKS ARE PROVIDED,

THEY SHALL BE CONNECTED TO AN UNSW ITCHED LINE.

G. LUMINAIRES INDICATED W ITH MULTI-LEVEL SW ITCHING SHALL HAVE

SIMILAR LAMPS CONTROLLED TOGETHER, I.E. INBOARD AND OUTBOARD

LAMPS OR RIGHT AND LEFT HAND LAMPS.

H. ALL LIGHTING FIXTURE LENSES, PARABOLIC LOUVERS, DOW NLIGHTING

ALZAK CONES AND "PARACUBE" LOUVERS SHALL BE HANDLED W ITH

COTTON GLOVES DURING INSTALLATION AND LAMPING TO AVOID

FINGERPRINTS OR DIRT DEPOSITS. IT IS PREFERRED THAT FIXTURES

BE SHIPPED AND INSTALLED W ITH CLEAR PLASTIC BAGS TO PROTECT

LOUVERS. AT CLOSE OF PROJECT, AND AFTER CONSTRUCTION AIR

FILTERS ARE CHANGED, REMOVE BAGS. ANY LOUVER OR CONE

SHOW ING DIRT OR FINGER PRINTS SHALL BE CLEANED W ITH SOLVENT

RECOMMENDED BY THE MANUFACTURER, OR REPLACED AS

NECESSARY IN ORDER TO TURN OVER TO THE OW NER NEW FIXTURES

AT OCCUPANCY.

I. RECESSED LUMINAIRES SHALL BE SECURED SUCH THAT THE FORCE

REQUIRED INSERTING LAMPS, TRIMS, LENSES, LOUVERS, OR DOOR

FRAMES DOES NOT SHIFT HOUSING. ALL TRIMS SHALL BE COMPLETELY

FLUSH W ITH FINISHED CEILINGS AT COMPLETION OF CONSTRUCTION.

J. CONTRACTOR SHALL PROVIDE UNSW ITCHED CONDUCTOR TO ALL EXIT

SIGNS, EMERGENCY INVERTER BATTERY PACKS, AND NIGHT LIGHTS AS

REQUIRED.

NORTH

0' 4' 8' 16'

SCALE 1/8" = 1'-0"

TAGGED NOTES

L1 REFER TO TYPICAL ENLARGED PATIENT ROOM PLANS ON

DRAWING ES501 FOR WORK REQUIRED IN SHADED AREA

INDICATED. ROOMS MAY BE REVERSED AND/ OR MIRROR

IMAGE BUT ORIENTATION TO HEADWALL, FOOTWALL, ETC.

SHALL BE THE SAME REGARDLESS. NOTE: CERTAIN DEVICE

LOCATIONS ARE AS SPECIFICALLY NOTED ON THESE FLOOR

PLANS WHERE DIFFERENCES WERE NOTED FROM THE

TYPICAL DESIGN. ANY FURTHER DEVIATIONS DISCOVERED

SHOULD BE COORDINATED WITH THE ARCHITECT PRIOR TO

OUTLET ROUGH-IN.

L5 CONNECT NEW FIXTURES TO EXISTING 277V LIFE SAFETY

CIRCUIT IN THIS AREA.

L15 PROJECT DEDUCT ALTERNATE 6 AREA. ALL WORK SCOPE

WITHIN THIS AREA SHALL BE REMOVED FROM THE PROJECT IF

THE ALTERNATE IS ACCEPTED, ALL EXISTING ITEMS / DEVICES

PRESENTLY LOCATED IN THIS AREA SHALL REMAIN.

L16 EXCLUDE ALL WORK IN THIS AREA, FROM CEILING PLANE TO

FLOOR.

1/8" = 1'-0"ES201

2 THIRD FLOOR PLAN - 3A, LIGHTING

TYPICAL ROOM JUNCTION BOX CONNECTION LEGEND

N1 - 120V NORMAL POW ER CIRCUIT (SEE CONTINUATION ON POW ER

DRAW ING ES301).

N2 - 277V NORMAL POW ER LIGHTING CIRCUIT (SEE CONTINUATION ON

LIGHTING DRAW ING ES201).

E1 - 120V EMERGENCY CRITICAL POW ER CIRCUIT (SEE CONTINUATION ON

POW ER DRAW ING ES301).

E2 - 277V EMERGENCY CRITICAL LIGHTING CIRCUIT (SEE CONTINUATION ON

LIGHTING DRAW ING ES201).

E3 - 120V EMERGENCY CRITICAL ''BOOM'' POW ER CIRCUIT (SEE

CONTINUATION ON POW ER DRAW ING ES301).

G1 - 120V NORMAL POW ER GFI CIRCUIT (SEE CONTINUATION ON POW ER

DRAW ING ES301).

REVISIONS: DATE:

ISSUE FOR BID 04/07/2021

J

J

J

JJ JJJJ JJJ JJJJJ J

JJ JJJJ JJ JJJJ JJJ

J

J

JJ J

J

J

JJ J

J

ICU STORAGE

3A-314

SOILED UTILITY

3A-316

MEDICATION ROOM

3A-320

CLEAN SUPPLIES

3A-318

TOILET ROOM

3A-309

OFFICE

3A-306

STAFF TOILET

3A-315A1

STAFF TOILET

3A-313

STAFF LOUNGE

3A-315E

PATIENT SHOW ER

3A-326

ICU PATIENT ROOM

3A-321

ICU PATIENT ROOM

3A-323

ICU PATIENT ROOM

3A-324

ICU PATIENT ROOM

3A-332

ICU PATIENT ROOM

3A-331

ICU PATIENT ROOM

3A-330

ICU PATIENT ROOM

3A-329 BARIATRIC ISOLATION ROOM

3A-328A

CONFERENCE ROOM

3A-308

TELE. RM.

3A-310

ELEC. RM.

3A-340

ICU TOILET

3A-331A

ICU TOILET

3A-329A

ICU TOILET

3A-319A

ANTE ROOM

3A-328

ISOLATION TOILET

3A-328B

ANTE ROOM

3A-325

ICU TOILET

3A-324A

ICU TOILET

3A-323A

ICU TOILET

3A-321A

ICU PATIENT ROOM

3A-319

NOURISHMENT

3A-317

ICU TOILET

3A-332A

ICU TOILET

3A-330A

ISOLATION TOILET

3A-325B

W ORKROOM

3A-305

CONSULT ROOM

3A-304

LINEN ALCOVE

3A-312

ISOLATION ROOM

3A-325A

HAC

3A-311

OFFICE

3A-315A

PHARM. OFFICE

3A-315B

NURSE MANAGER OFFICE

3A-315C

NURSE SUPERVISOR OFFICE

3A-315D

W ORKROOM

3A-315

TOILET ROOM

3A-307

E

E

E

E

E

E

E

E

E/GFI

E/GFI

GFI

E

E

GFI

GFI

ES501

ES501

ES502

E

E

E

E

E

E

E

GFI

GFI

E

E

GFI

GFI

E

GFI

E

E

E/GFI

E

E

E

E

E

E

E

E

SAT. NURSE STATION

3A-338

E.

E

IT

3A-303

BIOMED

3A-302

NURSE STATION

3A-322

(TYP)

P13

(TYP)

P13

(TYP)

P13

(TYP)

P13

(TYP)

P13

(TYP)

P13

(TYP)

P13

(TYP)

P13

(TYP)

P13

(TYP)

P13

(TYP)

P14

(TYP)

P12

(TYP)

P12

(TYP)

P10

(TYP)

P10

E

E

E

E

E

E

ES502

FP

FP

FP

N1 G1

N1

G1

-21RP-3A

-20RP-3A

-27EP-3A

-29EP-3A

-22RP-3A

-23RP-3A

N1G1

-24RP-3A

-25RP-3A

-28EP-3A

N1G1

-28RP-3A

-29RP-3A

-30EP-3A

N1 G1

-31EP-3A

-26RP-3A

-27RP-3A

N1 G1

N1G1

-32EP-3A

-38RP-3A

-39RP-3A

-33EP-3A

-37RP-3A

-36RP-3A

N1 G1

-37EP-3A

-32RP-3A

-33RP-3A

N1G1

-35EP-3A

-34RP-3A

-35RP-3A

N1G1

-39EP-3A

-31RP-3A

-30RP-3A

CORRIDOR

C13

-40EP-3A

-3RP-3A

-5RP-3A

-19RP-3A

E

-18RP-3A

-1EP-3A

-4EP-3A

-3EP-3A

-2EP-3A

-5EP-3A

-34EP-3A

-10EP-3A

-7EP-3A

-12EP-3A

-8EP-3A

-9EP-3A

-11EP-3A

-14EP-3A

-13EP-3A

-16EP-3A

-18EP-3A

-19EP-3A

CORRIDOR

C15

-20EP-3A

-4RP-3A

-7RP-3A

-6RP-3A

-9RP-3A

-8RP-3A

-14RP-3A

-17RP-3A

-16RP-3A

-21EP-3A

-10RP-3A

-13RP-3A

-12RP-3A

-23EP-3A

-24EP-3A

-25EP-3A

-15RP-3A

-26EP-3A

-40RP-3A

CORRIDOR

C12-41RP-3A

-43RP-3A

-77RP-3C

-73RP-3C

-47RP-3C

-11EP-3C

-9EP-3C

FRIDGE

ICE

COFFEE

MICRO

FRIDGE

MICRO

ICE

COFFEE

E -41EP-3A

U.C, FRIDGE

MED.

STORAGE

W ARMER

COPIER

C/S

-7EP-3C

-71RP-3C

-64RP-3C

FP

-66RP-3C

-8EP-3C

-45RP-3C

T

-11RP-3A

-51RP-3A

-17EP-3C

-22EP-3A

E

E

-6EP-3A

E .

E

-38EP-3A

GFI

E

6' - 0"

E3-68EP-3A

-69EP-3A

-70EP-3A

-71EP-3A

E3-48EP-3A

-49EP-3A

-50EP-3A

-51EP-3A

E3

-42EP-3A

-44EP-3A

-46EP-3A

-47EP-3A

E3

-52EP-3A

-53EP-3A

-54EP-3A

-55EP-3A

E3

-60EP-3A

-61EP-3A

-62EP-3A

-63EP-3A

E3-56EP-3A

-57EP-3A

-58EP-3A

-59EP-3A

E3-76EP-3A

-77EP-3A

-78EP-3A

-79EP-3A

E3

-64EP-3A

-65EP-3A

-66EP-3A

-67EP-3A

E3

-72EP-3A

-73EP-3A

-74EP-3A

-75EP-3A

E3

-80EP-3A

-81EP-3A

-82EP-3A

-83EP-3A

-1RP-3A

-2RP-3A

-70RP-3C

FP

4' - 0"

4' - 0"

4' - 0"

GFI

E

P11

-15EP-3A

-17EP-3A

-87EP-3A

-85EP-3A

E1 E1

E1 E1

E1 E1 E1 E1 E1

SHREDDER

CABINET

7 9

6.9

A

B

C D

E

F

7.7 8.3

B.6

W P/GFI

P2

EF-71-B

(TYP)

P19

-46RP-3A

-19,21,23MP-3C

EF-71-A

-20,22,24MP-3C

-89EP-3A-84EP-3A

-107EP-3A-102EP-3A

-100EP-3A

-105EP-3A

-98EP-3A

-103EP-3A -96EP-3A

-101EP-3A

-99EP-3A -94EP-3A

-92EP-3A

-97EP-3A

-95EP-3A -90EP-3A-88EP-3A

-93EP-3A

-86EP-3A

-91EP-3A

P22

P22

P22

P33

P33

P33

13100 watertown plank road suite 200 elm grove, wi 53122

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

Nagel Architects + Engineers project number:

BLDG 500 RENOVATE 3A 613-19-100

19025

CMTA CONSULTING ENGINEERS, INC.

10411 MEETING STREET,

PROSPECT, KY 40059

(502)326-3085

VOLUME AC

U s e rs

\b k a rc h e r\

D o c u m e n ts

\V M

W V

-0 -E

-R b k a rc h e rR U

V A

B .r v t

/5

/2

:2

:4

P

M

ES301

THIRD FLOOR PLAN - 3A, POWER

510 BUTLER AVENUE MARTINSBURG, WV 25405

04/07/2021 PDY BBK

BID DOCUMENTS

FULLY

SPRINKLERED

1/8" = 1'-0"ES301

1 THIRD FLOOR PLAN - 3A, POWER

NORTH

0' 4' 8' 16'

SCALE 1/8" = 1'-0"

TAGGED NOTES

P2 PROVIDE UNISTRUT AS REQUIRED FOR MOUNTING SERVICE

RECEPTACLES ON ROOF. COORDINATE EXACT MOUNTING

LOCATION WITH ALL TRADES PRIOR TO ROUGH-IN.

P10 REFER TO ENLARGED PLAN OF ELECTRICAL ROOM ON

DRAWING ES502.

P11 PROVIDE CIRCUITRY AND CONNECTIONS FOR P-TUBE

STATION. PNEUMATIC TUBE TRANSFER STATION FINAL

LOCATION(S) TO BE DETERMINED BY OWNER'S VENDOR.

P12 PROVIDE PLUGMOLD STRIP LENGTH AS INDICATED.

PLUGMOLD SHALL BE BRUSHED ALUMINUM WITH 20A OUTLETS

SPACES AT 18” ON CENTERS. EMERGENCY RECEPTACLES

SHALL BE RED IN COLOR AND SHALL HAVE CIRCUIT

IDENTIFICATION (SEE GENERAL NOTE - THIS SHEET) MOUNT

AT 48" AFF.

P13 REFER TO TYPICAL ENLARGED PATIENT ROOM PLANS ON

DRAWING ES501 FOR WORK REQUIRED IN SHADED AREA

INDICATED. ROOMS MAY BE REVERSED AND/ OR MIRROR

IMAGE BUT ORIENTATION TO HEADWALL, FOOTWALL, ETC.

SHALL BE THE SAME REGARDLESS. NOTE: CERTAIN DEVICE

LOCATIONS ARE AS SPECIFICALLY NOTED ON THESE FLOOR

PLANS WHERE DIFFERENCES WERE NOTED FROM THE

TYPICAL DESIGN. ANY FURTHER DEVIATIONS DISCOVERED

SHOULD BE COORDINATED WITH THE ARCHITECT PRIOR TO

OUTLET ROUGH-IN.

P14 REFER TO ENLARGED PLAN OF DATA ROOM ON DRAWING

ES502.

P19 VARIABLE FREQUENCY DRIVE (VFD) WITH INTEGRAL

DISCONNECT SWITCH - REFER TO MECHANICAL EQUIPMENT

SCHEDULES FOR FURTHER REQUIREMENTS. (TYPICAL)

P22 PROJECT DEDUCT ALTERNATE 6 AREA. ALL WORK SCOPE

WITHIN THIS AREA SHALL BE REMOVED FROM THE PROJECT IF

THE ALTERNATE IS ACCEPTED, ALL EXISTING ITEMS / DEVICES

PRESENTLY LOCATED IN THIS AREA SHALL REMAIN.

P33 EXCLUDE ALL WORK IN THIS AREA, FROM CEILING PLANE TO

FLOOR.

GENERAL NOTES (POWER):

A. REFER TO THE ARCHITECT'S REFLECTED CEILING PLANS, ELEVATIONS,

AND CASEW ORK DETAILS FOR EXACT LOCATIONS OF ALL W ALL AND

CEILING MOUNTED ELECTRICAL DEVICES.

B. CONTRACTOR SHALL FOLLOW BRANCH CIRCUITING LAY-OUT, AS

INDICATED ON THE FLOOR PLANS, W ITH A MAXIMUM OF THREE (3)

BRANCH CIRCUITS PER HOMERUN. EACH BRANCH CIRCUIT SHALL BE

PROVIDED W ITH A DEDICATED NEUTRAL CONDUCTOR. DEDICATED

NEUTRAL CONDUCTORS SHALL BE CONSIDERED CURRENT

CARRYING. IF ADDITIONAL CONDUCTORS ARE RAN IN THE SAME

CONDUIT W ITH THOSE INDICATED, CONTRACTOR SHALL DERATE ALL

CURRENT CARRYING CONDUCTORS PER NEC 310.15(B)(3), AND UPSIZE

CONDUIT AS REQUIRED PER NEC 300.17 AND ANNEX C. MULTIW IRE

BRANCH CIRCUITS AS DEFINED IN NEC 100 / 210.4 (CIRCUITS SHARING A

COMMON NEUTRAL CONDUCTOR) SHALL NOT BE PERMITTED.

C. ALL DEVICE COVERPLATES SHALL BE #302 STAINLESS STEEL. IDENTIFY

THE PANEL AND CIRCUIT NUMBER FOR ALL RECEPTACLES, SW ITCHES,

ETC. IN AREA OF CONSTRUCTION. PROVIDE CLEAR ADHESIVE LABELS

W ITH BLACK LETTERING. IN HEALTHCARE FACILITIES, ENGRAVE

EMERGENCY DEVICE COVERPLATES IN PATIENT CARE AREAS. MARK

INSIDES OF ALL DEVICE BOXES W ITH PANEL AND CIRCUIT NUMBER.

D. RECEPTACLES THAT ARE CONTROLLED BY AN AUTOMATIC MEANS

SUCH AS OCCUPANCY SENSOR OR ENERGY MANAGEMENT SYSTEM

SHALL BE MARKED IN ACCORDANCE W ITH NEC 406.3(E).

E. LOCATIONS OF ELECTRICAL CONNECTIONS AND LOCAL DISCONNECTS

SHALL BE COORDINATED W ITH MECHANICAL AND PLUMBING

CONTRACTORS TO ENSURE ACCESS AND W ORKING CLEARANCE IS

MAINTAINED PER NEC. NOTIFY OTHER TRADES OF REQUIRED

CLEARANCE AREAS TO AVOID ROUTING OF OTHER SYSTEMS IN THESE

AREAS. DO NOT INSTALL ELECTRICAL EQUIPMENT OVER EQUIPMENT

NAMEPLATES OR ACCESS PANELS OR THROUGH

ACCESS/MAINTENANCE CLEARANCES OF EQUIPMENT BY OTHER

TRADES.

TYPICAL ROOM JUNCTION BOX CONNECTION LEGEND

N1 - 120V NORMAL POW ER CIRCUIT (SEE CONTINUATION ON POW ER

DRAW ING ES301).

N2 - 277V NORMAL POW ER LIGHTING CIRCUIT (SEE CONTINUATION ON

LIGHTING DRAW ING ES201).

E1 - 120V EMERGENCY CRITICAL POW ER CIRCUIT (SEE CONTINUATION ON

POW ER DRAW ING ES301).

E2 - 277V EMERGENCY CRITICAL LIGHTING CIRCUIT (SEE CONTINUATION ON

LIGHTING DRAW ING ES201).

E3 - 120V EMERGENCY CRITICAL ''BOOM'' POW ER CIRCUIT (SEE

CONTINUATION ON POW ER DRAW ING ES301).

G1 - 120V NORMAL POW ER GFI CIRCUIT (SEE CONTINUATION ON POW ER

DRAW ING ES301).

W P/GFI

P2

(TYP)

P19

EF-70-B

PA-RP

P17

EXISTING

277/480V

NORMAL POW ER

PANEL "MP-PH"

EXISTING

277/480V

NORMAL POW ER

MOTOR CONTROL

CENTER "MCC-1A"

TO REMAIN

EXISTING

277/480V

NORMAL POW ER

PANEL "P-P"

TO REMAIN

EXISTING

277/480V

EM-CRITICAL

PANEL "EMDP"

TO REMAIN

EXISTING

277/480V

EM-ELEVATOR

PANEL "EDP"

TO REMAIN

EXISTING

600A

EM-ELEVATOR

"ATS-EDP"

TO REMAIN

EXISTING

120/208V

NORMAL POW ER

PANEL "PA-RP"

TO REMAIN

EXISTING

277/480V

EM-LIFE SAFETY

PANEL "DP-LS"

TO REMAIN

7 9

B

C D

E

F

7.7 8.3

B.6

EF-70-A

-7,9,11MP-PH

-8,10,12MP-PH

13100 watertown plank road suite 200 elm grove, wi 53122

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

Nagel Architects + Engineers project number:

BLDG 500 RENOVATE 3A 613-19-100

19025

CMTA CONSULTING ENGINEERS, INC.

10411 MEETING STREET,

PROSPECT, KY 40059

(502)326-3085

VOLUME AC

U s e rs

\b k a rc h e r\

D o c u m e n ts

\V M

W V

-0 -E

-R b k a rc h e rR U

V A

B .r v t

/5

/2

:2

:4

P

M

ES302

ROOF PLAN - 3A, ELECTRICAL

510 BUTLER AVENUE MARTINSBURG, WV 25405

04/07/2021 PDY BBK

BID DOCUMENTS

FULLY

SPRINKLERED

GENERAL NOTES (ROOF):

A. REFER TO POW ER, SYSTEMS, AND LIGHTING PLANS FOR GENERAL

NOTES APPLICABLE TO INTERIOR SPACES SHOW N ON THIS PLAN.

B. CONTRACTOR SHALL FOLLOW BRANCH CIRCUITING LAY-OUT, AS

INDICATED ON THE FLOOR PLANS, W ITH A MAXIMUM OF THREE (3)

BRANCH CIRCUITS PER HOMERUN. EACH BRANCH CIRCUIT SHALL BE

PROVIDED W ITH A DEDICATED NEUTRAL CONDUCTOR. DEDICATED

NEUTRAL CONDUCTORS SHALL BE CONSIDERED CURRENT

CARRYING. IF ADDITIONAL CONDUCTORS ARE RAN IN THE SAME

CONDUIT W ITH THOSE INDICATED, CONTRACTOR SHALL DERATE ALL

CURRENT CARRYING CONDUCTORS PER NEC 310.15(B)(3), AND UPSIZE

CONDUIT AS REQUIRED PER NEC 300.17 AND ANNEX C. MULTIW IRE

BRANCH CIRCUITS AS DEFINED IN NEC 100 / 210.4 (CIRCUITS SHARING A

COMMON NEUTRAL CONDUCTOR) SHALL NOT BE PERMITTED.

C. IDENTIFY THE PANEL AND CIRCUIT NUMBER FOR ALL RECEPTACLES,

SW ITCHES, ETC. IN AREA OF CONSTRUCTION. PROVIDE ENGRAVED

LAMACOID LABLES FOR ALL EXTERIOR DEVICES. MARK INSIDES OF ALL

DEVICE BOXES W ITH PANEL AND CIRCUIT NUMBER.

D. PROVIDE UNI-STRUT AS REQUIRED FOR MOUNTING OF ALL DEVICES ON

ROOF. COORDINATE W ITH ROOFING CONTRACTOR PRIOR TO

CONSTRUCTION FOR ALL PENETRATIONS. SEAL PENETRATIONS AS

REQUIRED PER ROOFING CONTRACTOR AND ROOFING

MANUFACTURER'S RECOMMENDATIONS AS REQUIRED TO MAINTAIN

ROOF W ARRANTY. PROVIDE CURBS AND/OR FLASHED BOOTS AT ALL

DEVICES AND PENETRATIONS.

E. CONDUITS SHALL PENETRATE ROOF FROM BELOW AS CLOSE TO FINAL

ROOF EQUIPMENT TERMINATION POINT AS POSSIBLE. SUPPORT ALL

ROOF MOUNTED CONDUITS AT INTERVALS NOT EXCEEDING 10 FEET

W ITH STRUT-BASED SUPPORT SYSTEM. SUPPORT SYSTEM TO BE

CADDY PYRAMID ST SERIES OR APPROVED EQUAL.

F. ALL CONDUIT EXPOSED TO DIRECT SUNLIGHT SHALL BE AT LEAST 12''

ABOVE THE ROOF-TOP. NO CONDUIT SHALL BE EXPOSED TO DIRECT

SUNLIGHT BELOW THIS HEIGHT.

G. W HERE RACEW AY OR CONDUCTORS ARE INSTALLED EXPOSED ON

ROOF, DERATE AMPACITY OF CONDUCTORS IN ACCORDANCE W ITH

NEC.

H. LOCATIONS OF ELECTRICAL CONNECTIONS AND LOCAL DISCONNECTS

SHALL BE COORDINATED W ITH MECHANICAL AND PLUMBING

CONTRACTORS TO ENSURE ACCESS AND W ORKING CLEARANCE IS

MAINTAINED PER NEC. NOTIFY OTHER TRADES OF REQUIRED

CLEARANCE AREAS TO AVOID ROUTING OF OTHER SYSTEMS IN THESE

AREAS. DO NOT INSTALL ELECTRICAL EQUIPMENT OVER EQUIPMENT

NAMEPLATES OR ACCESS PANELS OR THROUGH

ACCESS/MAINTENANCE CLEARANCES OF EQUIPMENT BY OTHER

TRADES.

I. PROVIDE MAINTENANCE RECEPTACLE W ITHIN 25 FT OF EACH

MECHANICAL UNIT AS REQUIRED BY NEC. COORDINATE INSTALLATION

LOCATIONS W ITH FINAL EQUIPMENT LAYOUT PROVIDE BY MECHANICAL

CONTRACTOR.

J. CONDUIT FOR ROOF MOUNTED EQUIPMENT SHALL BE ROUTED IN

CEILING SPACE BELOW ROOF DECK UNO.

TAGGED NOTES

P2 PROVIDE UNISTRUT AS REQUIRED FOR MOUNTING SERVICE

RECEPTACLES ON ROOF. COORDINATE EXACT MOUNTING

LOCATION WITH ALL TRADES PRIOR TO ROUGH-IN.

P17 ROUTE NUMBER OF #12 CONDUCTORS AS INDICATED IN 3/4''

CONDUIT TO NEW / SPARE 20A/1P BREAKER(S) IN EXISTING

PANEL INDICATED. WHERE EXISTING PANEL IS

FLUSH-MOUNTED IN AN EXISTING WALL, CONTRACTOR SHALL

CUT, PATCH AND REPAIR WALL AS REQUIRED FOR

CONCEALED CONDUIT ENTRY.

P19 VARIABLE FREQUENCY DRIVE (VFD) WITH INTEGRAL

DISCONNECT SWITCH - REFER TO MECHANICAL EQUIPMENT

SCHEDULES FOR FURTHER REQUIREMENTS. (TYPICAL)

NORTH

GENERAL NOTES (LIGHTNING PROTECTION SYSTEM ):

A. LIGHTNING PROTECTION LAYOUT SHOW N IS INTENDED TO CONVEY

SCOPE OF PROJECT. CONTRACTOR SHALL PROVIDE FINAL DESIGN

AND INSTALLATION FOR A COMPLETE LIGHTNING PROTECTION

SYSTEM FOR THIS FACILITY. SYSTEM SHALL COMPLY W ITH UL #96A

"MASTER LABELED LIGHTNING PROTECTION SYSTEMS'' AND NFPA 780.

REFER TO THE ELECTRICAL SPECIFICATION SECTION 264113

"LIGHTNING PROTECTION FOR STRUCTURES" FOR ADDITIONAL

REQUIREMENTS.

B. CONTRACTOR SHALL PROVIDE BONDING PROTECTION TO ALL

CAMERAS.

C. PENETRATIONS THROUGH SHEET METAL INCLUDING BUT NOT LIMITED

TO COPINGS, AND COUNTER FLASHINGS SHALL NOT BE ALLOW ED.

CONNECTIONS TO PARAPETS SHALL BE BY CLAMPS MADE TO FASTEN

TO THE DRIP EDGE OF COPINGS W ITHOUT PENETRATION TO AND OF

THE COPINGS. REFER TO ARCHITECTURAL ROOF PLAN FOR DETAILS

OF PENETRATIONS THROUGH HORIZONTAL ROOF AREAS.

PENETRATIONS THROUGH HORIZONTAL ROOF AREAS SHALL BE NO

CLOSER THAN 16'' TO ANY VERTICAL BUILDING SURFACE.

D. ALL ROOF PENETRATIONS AND ASSOCIATED LABOR COSTS SHALL BE

AT THE EXPENSE OF THIS CONTRACTOR, BUT SHALL BE INSTALLED BY

THE ROOFING CONTRACTOR IN ORDER TO MAINTAIN ANY APPLICABLE

ROOF W ARRANTIES. ANY DEVIATIONS NECESSARY BY THIS

CONTRACTOR SHALL FIRST BE SUBMITTED TO THE ARCHITECT's

OFFICE FOR REVIEW . ANY COSTS ASSOCIATED W ITH CHANGES TO

THIS SYSTEM THAT ARE A RESULT OF PROPOSED DETAILS NOT BEING

ACCEPTABLE TO THE OW NER, ARCHITECT OR ENGINEER SHALL BE AT

THE EXPENSE OF THIS CONTRACTOR. ALL REQUIRED CONNECTION

DEVICES SHALL BE REVIEW ED BY THE ARCHITECT AND ENGINEER.

PENETRATION DEVICES THROUGH STANDING SEAM METAL ROOF

AREAS SHALL BE PROVIDED BY THE SHEET METAL ROOFING

CONTRACTOR.

E. ALL CABLING/W IRING SHALL BE CONCEALED W ITHIN THE BUILDING.

ROUTE ALL CONCEALED CABLING IN SCHEDULE 80 PVC CONDUIT.

F. PROVIDE LIGHTNING PROTECTION SYSTEM EXTENSION FOR ADDED

ROOFTOP HVAC EQUIPMENT AT THIS FACILITY. SYSTEM SHALL COMPLY

W ITH UL 96A “MASTER LABELED LIGHTNING PROTECTION SYSTEMS”,

NFPA 780 AND THE PROJECT SPECIFICATIONS.

G. W HERE ELEMENTS OF THE SYSTEM ARE IN DIRECT CONTACT W ITH THE

ALUMINUM BUILDING MATERIALS, UTILIZE ALUMINUM EQUIPMENT.

W HERE IN CONTACT W ITH ANY OTHER BUILDING MATERIALS, UTILIZE

COPPER EQUIPMENT.

H. AIR TERMINALS SHALL BE INSTALLED W ITH-IN 2'-0" OF OUTSIDE

BUILDING EDGE, OUTSIDE CORNERS AND RIDGE ENDS - SPACING

BETW EEN AIR TERMINALS NOT TO EXTEND 20 FT.

I. NO BEND OF A CONDUIT SHALL FORM AN ANGLE MORE THAN 90

DEGREES NOR SHALL HAVE A RADIUS OF BEND THAN 8".

J. CONDUCTORS W ITHIN BUILDING SHALL BE IN 1" CONDUIT.

K. THE STEEL COLUMNS OF THE BUILDING SHALL BE USED AS THE DOW N

CONDUCTORS.

L. BOND ALL ROOF DRAINS, AHU HOUSING, ANTENNAS AND OTHER ROOF

MOUNTED METALLIC OBJECTS TO THE SYSTEM IN AN APPROVED

MANNER.

M. ALL UNDERGROUND METALLIC OBJECTS LOCATED W ITHIN 6 FEET OF

THE SYSTEM SHALL BE BONDED TO THE SYSTEM IN AN APPROVED

MANNER.

N. PROPER FLASHING AND PITCH POCKETS SHALL BE PROVIDED FOR ALL

ROOF PENETRATIONS.

O. ALL ROOF PENETRATIONS AND ALL ITEMS FASTENED TO

ARCHITECTURAL ELEMENTS OF THE BUILDING SHALL MEET W ITH THE

ARCHITECT'S APPROVAL.

P. BOND ENTIRE SYSTEM TOGETHER TO THE COLD W ATER MAINS

ENTERING THE BUILDING IN AN APPROVED MANNER.

Q. INTERCONNECT LIGHTNING PROTECTION GROUND TO ELECTRIC,

TELEPHONE AND OTHER BUILDING GROUND SYSTEMS AS SHOW N OR

AS REQUIRED BY CODE.

R. THE SYSTEM SHALL BE THE PRODUCT OF ONE MANUFACTURER

REGULARLY ENGAGED IN THE PRODUCTION OF LIGHTNING

PROTECTION SYSTEMS AND SHALL BE REGISTERED AND APPROVED BY

THE LIGHTNING PROTECTION INSTITUTE.

0' 4' 8' 16'

SCALE 1/8" = 1'-0"1/8" = 1'-0"ES302

1 ROOF PLAN - 3A, ELECTRICAL

S

S

S S

S

S

F

F

F

F

F F

F

MS

PC

DL

W AP

FF

S

S

S

S

S

S

SS

W AP

W AP

W AP

W AP

W AP

C C

PB

PB PB PB

PB

PB

F

CR

CR CR CR

CR

IM

IM

SSSS SSSS

SS

P

IM

DS

DS DS

DS

DS

J

J

J

J

P C

CR

LPA

DP

DD SM

DDDD

DS

CR IR

DS

CR IR

DS

W AP

W AP

W AP

W AP

W AP

W AP

ICU STORAGE

3A-314

SOILED UTILITY

3A-316

MEDICATION ROOM

3A-320CLEAN SUPPLIES

3A-318

TOILET ROOM

3A-309

OFFICE

3A-306

STAFF TOILET

3A-315A1

STAFF TOILET

3A-313

STAFF LOUNGE

3A-315E

PATIENT SHOW ER

3A-326

ICU PATIENT ROOM

3A-321

ICU PATIENT ROOM

3A-323

ICU PATIENT ROOM

3A-324

ICU PATIENT ROOM

3A-332

ICU PATIENT ROOM

3A-331

ICU PATIENT ROOM

3A-330

ICU PATIENT ROOM

3A-329

BARIATRIC ISOLATION ROOM

3A-328A

CONFERENCE ROOM

3A-308

TELE. RM.

3A-310

ELEC. RM.

3A-340

ICU TOILET

3A-331A

ICU TOILET

3A-329A

ICU TOILET

3A-319A

ANTE ROOM

3A-328

ISOLATION TOILET

3A-328B

ANTE ROOM

3A-325

ICU TOILET

3A-324A

ICU TOILET

3A-323A

ICU TOILET

3A-321A

ICU PATIENT ROOM

3A-319

NOURISHMENT

3A-317

ICU TOILET

3A-332A

ICU TOILET

3A-330A

ISOLATION TOILET

3A-325B

W ORKROOM

3A-305

CONSULT ROOM

3A-304

LINEN ALCOVE

3A-312

ISOLATION ROOM

3A-325A

HAC

3A-311

OFFICE

3A-315A

PHARM. OFFICE

3A-315B

NURSE MANAGER OFFICE

3A-315C

NURSE SUPERVISOR OFFICE

3A-315D

W ORKROOM

3A-315

CORRIDOR

C15

ES501

ES501

NURSE STATION

3A-322

IT

3A-303

BIOMED

3A-302

TOILET ROOM

3A-307

(TYP)

S1

(TYP)

S1

(TYP)

S2

(TYP)

S2

3D/1V

3D/1V

FS

FS

FS

3D/1V

ES502

C

T

FS

1D

6' - 0"

(TYP)

S5

(TYP)

S5

(TYP)

S5

(TYP)

S5 (TYP)

S5

(TYP)

S5

(TYP)

S5

(TYP)

S5

(TYP)

S5

(TYP)

S5

ELLS-3A

P17

3D/1V

3D/1V

3D/1V

S12

T-TUBE

STATION

S10

S10

S10

S10

ELLS-3A

P17

7 9

6.9

A

B

C D

E

F

7.7 8.3

B.6

ELLS-3A

P17

S18

S18

S18

S18

S11

S11

S11

S21

S21

S21

13100 watertown plank road suite 200 elm grove, wi 53122

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

Nagel Architects + Engineers project number:

BLDG 500 RENOVATE 3A 613-19-100

19025

CMTA CONSULTING ENGINEERS, INC.

10411 MEETING STREET,

PROSPECT, KY 40059

(502)326-3085

VOLUME AC

U s e rs

\b k a rc h e r\

D o c u m e n ts

\V M

W V

-0 -E

-R b k a rc h e rR U

V A

B .r v t

/5

/2

:2

:5

P

M

ES401

THIRD FLOOR PLAN - 3A,

SYSTEMS

510 BUTLER AVENUE MARTINSBURG, WV 25405

04/07/2021 PDY BBK

BID DOCUMENTS

FULLY

SPRINKLERED

1/8" = 1'-0"ES401

1 THIRD FLOOR PLAN - 3A, SYSTEMS

GENERAL NOTES (SYSTEMS):

A. REFER TO THE ARCHITECT'S REFLECTED CEILING PLANS, ELEVATIONS,

AND CASEW ORK DETAILS FOR EXACT LOCATIONS OF ALL W ALL AND

CEILING MOUNTED ELECTRICAL DEVICES.

B. CONTRACTOR SHALL FOLLOW BRANCH CIRCUITING LAY-OUT, AS

INDICATED ON THE FLOOR PLANS, W ITH A MAXIMUM OF THREE (3)

BRANCH CIRCUITS PER HOMERUN. EACH BRANCH CIRCUIT SHALL BE

PROVIDED W ITH A DEDICATED NEUTRAL CONDUCTOR. DEDICATED

NEUTRAL CONDUCTORS SHALL BE CONSIDERED CURRENT

CARRYING. IF ADDITIONAL CONDUCTORS ARE RAN IN THE SAME

CONDUIT W ITH THOSE INDICATED, CONTRACTOR SHALL DERATE ALL

CURRENT CARRYING CONDUCTORS PER NEC 310.15(B)(3), AND UPSIZE

CONDUIT AS REQUIRED PER NEC 300.17 AND ANNEX C. MULTIW IRE

BRANCH CIRCUITS AS DEFINED IN NEC 100 / 210.4 (CIRCUITS SHARING A

COMMON NEUTRAL CONDUCTOR) SHALL NOT BE PERMITTED.

C. ALL DEVICE COVERPLATES SHALL BE #302 STAINLESS STEEL. IDENTIFY

THE PANEL AND CIRCUIT NUMBER FOR ALL RECEPTACLES, SW ITCHES,

ETC. IN AREA OF CONSTRUCTION. PROVIDE CLEAR ADHESIVE LABELS

W ITH BLACK LETTERING. IN HEALTHCARE FACILITIES, ENGRAVE

EMERGENCY DEVICE COVERPLATES IN PATIENT CARE AREAS. MARK

INSIDES OF ALL DEVICE BOXES W ITH PANEL AND CIRCUIT NUMBER.

D. REFER TO "SYSTEM INSTALLATION MATRIX" (ON SYSTEMS LEGEND

SHEET) AND SPECIFICATIONS FOR CONTRACTOR REQUIREMENTS OF

EACH SYSTEM.

E. THE CONTRACTOR SHALL ROUTE ALL ''SYSTEM CONDUIT STUB-UPS'' TO

THE NEAREST CORRIDOR CABLING PATH (SEE ''STUB-UP'' DETAILS).

REFER TO CABLING PATH INSTALLATION DETAIL FOR ADDITIONAL

REQUIREMENTS.

F. CONTRACTOR SHALL PAINT ALL SYSTEMS CONDUIT STUB-UPS LIGHT

BLUE FOR SYSTEMS CABLING INTO THE CORRIDOR CABLING PATH.

PROVIDE PULL STRINGS IN ALL NEW CONDUIT RUNS FOR SYSTEM

CABLING INSTALLATION.

TAGGED NOTES

P17 ROUTE NUMBER OF #12 CONDUCTORS AS INDICATED IN 3/4''

CONDUIT TO NEW / SPARE 20A/1P BREAKER(S) IN EXISTING

PANEL INDICATED. WHERE EXISTING PANEL IS

FLUSH-MOUNTED IN AN EXISTING WALL, CONTRACTOR SHALL

CUT, PATCH AND REPAIR WALL AS REQUIRED FOR

CONCEALED CONDUIT ENTRY.

S1 PROPOSED J-HOOK CABLING PATH - COORDINATE ALL PATHS

WITH VENDOR's AND HOSPITAL STAFF (NOTE : STUB-UP

CONDUITS WILL NEED TO BE RAN TO THESE CABLING PATHS).

PROVIDE J-HOOKS ALONG ALL REQUIRED CABLING PATHS -

REFER TO INSTALLATION DETAIL ON DRAWING ES802 FOR

FURTHER REQUIREMENTS (TYPICAL). PROVIDE CONDUITS AND

SLEEVES WHERE REQUIRED DUE TO HARD/INACCESSIBLE

CEILING LOCATIONS. REFER TO REFLECTED CEILING PLAN

AND FIELD VERIFY EXACT REQUIREMENTS.

S2 CABLING CONTRACTOR SHALL INSTALL SLEEVES OF

SUFFICIENT SIZE AND QUANTITY FOR PATHWAY THROUGH

WALL. REFER TO SYSTEMS CABLING SLEEVE DETAIL ON

ES802. CABLING CONTRACTOR SHALL INSTALL ALL SLEEVES

PER MANUFACTURER INSTRUCTIONS.

S5 REFER TO TYPICAL ENLARGED PATIENT ROOM PLANS ON

DRAWING ES501 FOR WORK REQUIRED IN SHADED AREA

INDICATED. ROOMS MAY BE REVERSED AND/ OR MIRROR

IMAGE BUT ORIENTATION TO HEADWALL, FOOTWALL, ETC.

SHALL BE THE SAME REGARDLESS. NOTE: CERTAIN DEVICE

LOCATIONS ARE AS SPECIFICALLY NOTED ON THESE FLOOR

PLANS WHERE DIFFERENCES WERE NOTED FROM THE

TYPICAL DESIGN. ANY FURTHER DEVIATIONS DISCOVERED

SHOULD BE COORDINATED WITH THE ARCHITECT PRIOR TO

OUTLET ROUGH-IN.

S10 PROVIDE 4-DATA DROPS AT EACH FURNITURE CONNECTION.

S11 PROJECT DEDUCT ALTERNATE 6 AREA. ALL WORK SCOPE

WITHIN THIS AREA SHALL BE REMOVED FROM THE PROJECT IF

THE ALTERNATE IS ACCEPTED, ALL EXISTING ITEMS / DEVICES

PRESENTLY LOCATED IN THIS AREA SHALL REMAIN.

S12 CONTRACTOR TO VERIFY THE EXACT LOCATION OF DEVICE

INDICATED WITH OWNER / ARCHITECT PRIOR TO ROUGH-IN.

S18 OUTLET BOX ROUGH-IN FOR DEVICES INDICATED TO BE

PROVIDED UNDER SEPERATE CONTRACT ('3B' RENOVATION).

S21 EXCLUDE ALL WORK IN THIS AREA, FROM CEILING PLANE TO

FLOOR.

NORTH

0' 4' 8' 16'

SCALE 1/8" = 1'-0"

P

C

C B

S C

SD

S

P C

DLJ J J RF

J

J

DCCC

S P

C

C B

S C

SD

S

P C

DL

J

JJ J RF

J

DC

CC

J J

J J

ICU PATIENT ROOM

3A-331

ICU TOILET

3A-331A

GFI

USB

E

1' - 4" 2' - 0"

2' - 0"

5' - 0" T

PATIENT

LIFT

CEILING

BOOM

N1

G1 C

8' - 0"

2' - 0" 3D/1V

E 2' - 0"

2' - 0" E3

L11

P23

(TYP)

P24

E1

A

E 6' - 6"

6' - 6"

3D

2D

P31

S20

P32

ANTE ROOM

3A-325

ICU TOILET

3A-324A ISOLATION TOILET

3A-325B

ISOLATION ROOM

3A-325A

GFI

USB

1' - 4" 2' - 0"

E2' - 0"

5' - 0"

T

PATIENT

LIFT

CEILING

BOOM

N1

G1

2' - 0"

3D/1V

2' - 0"

2' - 0"

E

8' - 0"

B3

C

P23

L11

(TYP)

P24

E1

P25

P25

P25

C

D

B.6

E6' - 6"

3D6' - 6"

2D

S20

P31

P32

ICU PATIENT ROOM

3A-331

ICU TOILET

3A-331A

ICU TOILET

3A-330A

.D .N D4-15

D4-15

B1F

DS-10

V1

ST

B1F

B1F

E2

N2

H

H

L7

(TYP)

P24

L11

A

B.6

C

D

B1F

B1F B1F

D4-15G

ST

D4-15G

HG

DS-10

V1

HG

B1F

E2 N2

.D .N

L7

B1F

P25

P25

P25

L11

(TYP)

P24

C

D

B.6

13100 watertown plank road suite 200 elm grove, wi 53122

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

Nagel Architects + Engineers project number:

BLDG 500 RENOVATE 3A 613-19-100

19025

CMTA CONSULTING ENGINEERS, INC.

10411 MEETING STREET,

PROSPECT, KY 40059

(502)326-3085

VOLUME AC

U s e rs

\b k a rc h e r\

D o c u m e n ts

\V M

W V

-0 -E

-R b k a rc h e rR U

V A

B .r v t

/5

/2

:2

:5

P

M

ES501

ENLARGED PLANS

510 BUTLER AVENUE MARTINSBURG, WV 25405

04/07/2021 PDY BBK

BID DOCUMENTS

FULLY

SPRINKLERED

2' 4' 16'8'0

1/4" = 1'-0"

12'1'

SCALE: 1/4" = 1'-0"

THIRD FLOOR - POW ER/SYSTEMS - TYPICAL

ICU PATIENT ROOM

2' 4' 16'8'0

1/4" = 1'-0"

12'1'

SCALE: 1/4" = 1'-0"

THIRD FLOOR - POW ER/SYSTEMS - TYPICAL

ICU ISOLATION ROOM

GENERAL NOTES (POWER):

A. REFER TO THE ARCHITECT'S REFLECTED CEILING PLANS, ELEVATIONS,

AND CASEW ORK DETAILS FOR EXACT LOCATIONS OF ALL W ALL AND

CEILING MOUNTED ELECTRICAL DEVICES.

B. CONTRACTOR SHALL FOLLOW BRANCH CIRCUITING LAY-OUT, AS

INDICATED ON THE FLOOR PLANS, W ITH A MAXIMUM OF THREE (3)

BRANCH CIRCUITS PER HOMERUN. EACH BRANCH CIRCUIT SHALL BE

PROVIDED W ITH A DEDICATED NEUTRAL CONDUCTOR. DEDICATED

NEUTRAL CONDUCTORS SHALL BE CONSIDERED CURRENT

CARRYING. IF ADDITIONAL CONDUCTORS ARE RAN IN THE SAME

CONDUIT W ITH THOSE INDICATED, CONTRACTOR SHALL DERATE ALL

CURRENT CARRYING CONDUCTORS PER NEC 310.15(B)(3), AND UPSIZE

CONDUIT AS REQUIRED PER NEC 300.17 AND ANNEX C. MULTIW IRE

BRANCH CIRCUITS AS DEFINED IN NEC 100 / 210.4 (CIRCUITS SHARING A

COMMON NEUTRAL CONDUCTOR) SHALL NOT BE PERMITTED.

C. ALL DEVICE COVERPLATES SHALL BE #302 STAINLESS STEEL. IDENTIFY

THE PANEL AND CIRCUIT NUMBER FOR ALL RECEPTACLES, SW ITCHES,

ETC. IN AREA OF CONSTRUCTION. PROVIDE CLEAR ADHESIVE LABELS

W ITH BLACK LETTERING. IN HEALTHCARE FACILITIES, ENGRAVE

EMERGENCY DEVICE COVERPLATES IN PATIENT CARE AREAS. MARK

INSIDES OF ALL DEVICE BOXES W ITH PANEL AND CIRCUIT NUMBER.

D. RECEPTACLES THAT ARE CONTROLLED BY AN AUTOMATIC MEANS

SUCH AS OCCUPANCY SENSOR OR ENERGY MANAGEMENT SYSTEM

SHALL BE MARKED IN ACCORDANCE W ITH NEC 406.3(E).

E. LOCATIONS OF ELECTRICAL CONNECTIONS AND LOCAL DISCONNECTS

SHALL BE COORDINATED W ITH MECHANICAL AND PLUMBING

CONTRACTORS TO ENSURE ACCESS AND W ORKING CLEARANCE IS

MAINTAINED PER NEC. NOTIFY OTHER TRADES OF REQUIRED

CLEARANCE AREAS TO AVOID ROUTING OF OTHER SYSTEMS IN THESE

AREAS. DO NOT INSTALL ELECTRICAL EQUIPMENT OVER EQUIPMENT

NAMEPLATES OR ACCESS PANELS OR THROUGH

ACCESS/MAINTENANCE CLEARANCES OF EQUIPMENT BY OTHER

TRADES.

GENERAL NOTES (ENLARGED AND TYPICAL):

A. ALL ROOM LAYOUTS ARE TYPICAL AND MAY VARY OR MIRROR OTHER

ASSOCIATED ROOMS. CONTRACTOR SHALL REFER TO ARCHITECTURAL

ELEVATIONS AND COORDINATE EACH ROOM PRIOR TO ROUGH-IN.

2' 4' 16'8'0

1/4" = 1'-0"

12'1'

SCALE: 1/4" = 1'-0"

THIRD FLOOR - LIGHTING - TYPICAL ICU

PATIENT ROOM

TAGGED NOTES

L7 CURBELL #LVC-2000-004 DIMMING RELAY PROVIDED AND

INSTALLED BY THIS CONTRACTOR. MOUNT IN 5-GANG

MASONRY BOX AT THE HEADWALL (ABOVE SUSPENDED

CEILING) AS REQUIRED TO CONTROL HEADWALL DOWNLIGHT

UNITS. REFER ALSO TO "PATIENT READING LIGHT CONTROL

SCHEMATIC" ON DRAWING ES701.

L11 CONTRACTOR TO ROUTE CONTROL WIRING IN CONDUIT FROM

LIGHTING CONTROL RELAY INDICATED TO CONTROL READING

LIGHTS (FIXTURE TYPE "H" OR "HG") VIA NURSE CALL PATIENT

STATION FOR PATIENT PILLOW SPEAKER CONTROL.

COORDINATE EXACT WIRING REQUIREMENTS WITH NURSE

CALL SYSTEM MANUFACTURER AND RELAY MANUFACTURER

PRIOR TO ROUGH-IN.

P23 PROVIDE JUNCTION BOX ABOVE ACCESSIBLE CEILING (NEAR

AN ACCESS PANEL) FOR FUTURE ULTRAVIOLET (UV) LIGHT.

P24 ROOM POWER JUNCTION BOXES ABOVE ACCESSIBLE CEILING.

REFER TO LIGHTING / POWER FLOOR PLANS FOR

CONTINUATION. SUBSCRIPT LETTER BESIDE JUNCTION BOX

CORRESPONDS WITH LETTER ON FLOOR PLAN DRAWINGS.

(TYPICAL).

P25 PROVIDE NEOPRENE GASKET AROUND ALL OUTLET BOXES

(ON CEILINGS AND WALLS) WITHIN THE ISOLATION PATIENT

ROOMS (INCLUDING THE ANTE AND TOILET ROOMS). TYPICAL.

P31 CONTRACTOR TO WIRE THREE (3) OUTLETS IN SKYTRON

BOOM TO EACH CIRCUIT AND LABEL EACH OF THESE

SKYTRON BOOM OUTLETS FOR CIRCUIT IDENTIFICATION.

REFER TO SKYTRON BOOM VENDOR DRAWINGS FOR

ADDITIONAL REQUIREMENTS.

P32 PROVIDE AN ADDITIONAL EMERGENCY POWER DUPLEX

OUTLET WITHIN A STEEL ENCLOSURE (LOCATE ABOVE THE

CEILING AND PROVIDE PER VENDOR DRAWINGS) FOR THE

OWNERS DISPLAY INTERFACE. CONNECT TO ONE OF THE

EMERGENCY POWER CIRCUITS INDICATED FOR THE CEILING

BOOM.

S20 PROVIDE DATA OUTLET WITHIN BOOM EQUIPMENT AS

REQUIRED. COORDINATE CONNECTION REQUIREMENTS WITH

BOOM INSTALLATION.

2' 4' 16'8'0

1/4" = 1'-0"

12'1'

SCALE: 1/4" = 1'-0"

THIRD FLOOR - LIGHTING - TYPICAL ICU

ISOLATION ROOM

TYPICAL ROOM JUNCTION BOX CONNECTION LEGEND

N1 - 120V NORMAL POW ER CIRCUIT (SEE CONTINUATION ON POW ER

DRAW ING ES301).

N2 - 277V NORMAL POW ER LIGHTING CIRCUIT (SEE CONTINUATION ON

LIGHTING DRAW ING ES201).

E1 - 120V EMERGENCY CRITICAL POW ER CIRCUIT (SEE CONTINUATION ON

POW ER DRAW ING ES301).

E2 - 277V EMERGENCY CRITICAL LIGHTING CIRCUIT (SEE CONTINUATION ON

LIGHTING DRAW ING ES201).

E3 - 120V EMERGENCY CRITICAL ''BOOM'' POW ER CIRCUIT (SEE

CONTINUATION ON POW ER DRAW ING ES301).

G1 - 120V NORMAL POW ER GFI CIRCUIT (SEE CONTINUATION ON POW ER

DRAW ING ES301).

F

SD

SD

MS

MD

B

ELEC. RM.

3A-340

REMOVE ABANDONED

CABINET

REMOVE EXISTING

STACKING TRANSFORMERS

TOP-"T3" FOR "EP-3A" (30-KVA)

TOP-"T6" FOR "RP-3A" (30-KVA)

REMOVE EXISTING

120/208V

NORMAL POWER

DOUBLE-TUB

PANEL "RP-3A"

REMOVE EXISTING

277/480V

NORMAL POWER

PANEL "LP-3A"

REMOVE EXISTING

120/208V

EM-CRITICAL BRANCH

PANEL "EP-3A"

EXISTING 277/480V

EM-LIFE SAFETY

PANEL "ELS-3A"

TO REMAIN

EXISTING 120/208V

EM-LIFE SAFETY

PANEL "ELLS-3A"

TO REMAIN

EXISTING 9-KVA FLOOR-MTD.

TRANSFORMER FOR

"ELLS-3A" TO REMAIN

REMOVE EXISTING

277/480V

EM-CRITICAL POW ER

PANEL "ELP-3A"

P26

P26

P26

P26

B

ELEC. RM.

3A-340

B

P16

EXISTING 277/480V

EM-LIFE SAFETY

PANEL "ELS-3A"

TO REMAIN

EXISTING 9-KVA FLOOR-

MTD. TRANSFORMER FOR

"ELLS-3A" TO REMAIN

EXISTING 120/208V

EM-LIFE SAFETY

PANEL "ELLS-3A"

TO REMAIN

NEW REPLACEMENT

277/480V

EM-CRITICAL POW ER

PANEL "ELP-3A"

NEW REPLACEMENT

120/208V

EM-CRITICAL BRANCH

QUADRUPLE TUB

PANEL "EP-3A"

NEW REPLACEMENT

277/480V

NORMAL POWER

PANEL "LP-3A"

NEW REPLACEMENT

120/208V

NORMAL POWER

TRIPLE TUB

PANEL "RP-3A"

NEW REPLACEMENT

TRANSFORMERS

SUSPENDED FROM

CEILING STRUCTURE

(SEE DETAIL)

T-RP-3A

T-EP-3A

B

7.77.6

C

D

C

D

7.7

NAC

SEC

NC-A

AMP

NAC

SEC

NC-A

AMP

TV-A

IT

3A-303

BIOMED

3A-302

-49RP-3A

-45EP-3A

-36EP-3A

-43EP-3A

-1ELLS-3A

EXISTING

FIRE ALARM

3B

EXISTING

PACS

3B

EXISTING

NURSE CALL

3B

EXISTING

PAGING

3B

EXISTING

CATV

3B

NURSE CALL

3A

PAGING

3A

CATV

3A

FIRE ALARM

3A

PACS

3A

TV-A

C

D

7.7

7.77.6

C

D

C

D

7.7

IDF

EXISTING

DATA

RACKS

NACEXISTING

FIRE ALARM

3B

EXISTING

PACS

3B

SEC

NC-AEXISTING

NURSE CALL

3B

AMP

EXISTING

PAGING

3B

TV-A

EXISTING

CATV

3B

NAC

SEC

NC-A

NURSE CALL

3A

AMP PAGING

3A

TV-A

CATV

3A

TEL

TEL

FIRE ALARM

3A

PACS

3A

IT

3A-303

BIOMED

3A-302

NEW BACKBOARD AT

ROOM PERIMETER

NEW BACKBOARD AT

ROOM PERIMETER

C

D

7.7

T-EP-3C T-RP-3C

BD-1 BD-2 BD-3 BD-4

EXISTING BUS-

DUCT RISERS TO

REMAIN (TYP.)

LOCATION FOR FUTURE

PANEL TUB

SEC

EXISTING BUS-DUCT

RISERS TO REMAIN

(SEE POW ER RISER

FOR ADDITIONAL

REQUIREMENTS)

TV-A

EXISTING RADIO

EQUIP. TO REMAIN

EXISTING

REPLACEMENT

120/208V

EM-CRITICAL BRANCH

DOUBLE TUB

PANEL "EP-3C"

EXISTING 9-KVA FLOOR-MTD.

TRANSFORMER FOR

"ELLS-3C" TO REMAIN

EXISTING

REPLACEMENT

277/480V

NORMAL POWER

PANEL "LP-3C"

EXISTING

REPLACEMENT

277/480V

EM-CRITICAL POW ER

PANEL "ELP-3C"

EXISTING

PACS

TO REMAIN

EXISTING

TO REMAIN

EXISTING 120/208V

EM-LIFE SAFETY

PANEL "ELLS-3C"

TO REMAIN

EXISTING 277/480V

EM-LIFE SAFETY

PANEL "ELS-3C"

TO REMAIN

EXISTING REPLACEMENT

TRANSFORMERS SUSPENDED

FROM CEILING STRUCTURE (SEE

DETAIL)

LOCATION FOR FUTURE

PANEL TUB

EXISTING

REPLACEMENT

120/208V

NORMAL POW ER

DOUBLE TUB

PANEL "RP-3C"

EXISTING

277/480V

NORMAL POW ER

PANEL "MP-3C"

B

P16

T-EP-3B

T-RP-3B

EXISTING REPLACEMENT

TRANSFORMERS SUSPENDED FROM

CEILING STRUCTURE (SEE DETAIL)

LOCATION FOR FUTURE

PANEL TUB

EXISTING

REPLACEMENT

120/208V

NORMAL POWER

DOUBLE TUB

PANEL "RP-3B"

EXISTING

REPLACEMENT

277/480V

NORMAL POWER

PANEL "LP-3B"

EXISTING

REPLACEMENT

120/208V

EM-CRITICAL

BRANCH

DOUBLE TUB

PANEL "EP-3B"

EXISTING REPLACEMENT

277/480V

EM-CRITICAL POWER

PANEL "ELP-3B"

EXISTING 9-KVA FLOOR-MTD.

TRANSFORMER FOR

"ELLS-3B" TO REMAIN

EXISTING 277/480V

EM-LIFE SAFETY

PANEL "ELS-3B"

TO REMAIN

EXISTING 120/208V

EM-LIFE SAFETY

PANEL "ELLS-3B"

TO REMAIN

B

13100 watertown plank road suite 200 elm grove, wi 53122

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

Nagel Architects + Engineers project number:

BLDG 500 RENOVATE 3A 613-19-100

19025

CMTA CONSULTING ENGINEERS, INC.

10411 MEETING STREET,

PROSPECT, KY 40059

(502)326-3085

VOLUME AC

U s e rs

\b k a rc h e r\

D o c u m e n ts

\V M

W V

-0 -E

-R b k a rc h e rR U

V A

B .r v t

/5

/2

:2

:0

P

M

ES502

ENLARGED PLANS

510 BUTLER AVENUE MARTINSBURG, WV 25405

04/07/2021 PDY BBK

BID DOCUMENTS

FULLY

SPRINKLERED

2' 4' 16'8'0

1/4" = 1'-0"

12'1'

SCALE: 1/4" = 1'-0"

ENLARGED THIRD FLOOR "3A" ELECTRICAL

ROOM 348 - ELECTRICAL DEMOLITION

2' 4' 16'8'0

1/4" = 1'-0"

12'1'

SCALE: 1/4" = 1'-0"

THIRD FLOOR "3A" ELECTRICAL ROOM 348 -

ELECTRICAL NEW W ORK

2' 4' 16'8'0

1/4" = 1'-0"

12'1'

SCALE: 1/4" = 1'-0"

THIRD FLOOR "3A" IT AND BIO-MED ROOMS -

POW ER

2' 4' 16'8'0

1/4" = 1'-0"

12'1'

SCALE: 1/4" = 1'-0"

THIRD FLOOR "3A" IT AND BIO-MED ROOMS -

SYSTEMS

GENERAL NOTES (LIGHTING):

A. REFER TO THE ARCHITECT'S REFLECTED CEILING PLANS, ELEVATIONS,

AND CASEW ORK DETAILS FOR EXACT LOCATIONS OF ALL W ALL AND

CEILING MOUNTED ELECTRICAL DEVICES.

B. CONTRACTOR SHALL FOLLOW BRANCH CIRCUITING LAY-OUT, AS

INDICATED ON THE FLOOR PLANS, W ITH A MAXIMUM OF THREE (3)

BRANCH CIRCUITS PER HOMERUN. EACH BRANCH CIRCUIT SHALL BE

PROVIDED W ITH A DEDICATED NEUTRAL CONDUCTOR. DEDICATED

NEUTRAL CONDUCTORS SHALL BE CONSIDERED CURRENT

CARRYING. IF ADDITIONAL CONDUCTORS ARE RAN IN THE SAME

CONDUIT W ITH THOSE INDICATED, CONTRACTOR SHALL DERATE ALL

CURRENT CARRYING CONDUCTORS PER N.E.C. #310.15(B)(3), AND

UPSIZE CONDUIT AS REQUIRED PER N.E.C. #300.17 AND ANNEX

C. MULTIW IRE BRANCH CIRCUITS AS DEFINED IN N.E.C #100 / 210.4

(CIRCUITS SHARING A COMMON NEUTRAL CONDUCTOR) SHALL NOT BE

PERMITTED.

C. ALL DEVICE COVERPLATES SHALL BE #302 STAINLESS STEEL. IDENTIFY

THE PANEL AND CIRCUIT NUMBER FOR ALL RECEPTACLES, SW ITCHES,

ETC. IN AREA OF CONSTRUCTION. PROVIDE CLEAR ADHESIVE LABELS

W ITH BLACK LETTERING. IN HEALTHCARE FACILITIES, ENGRAVE

EMERGENCY DEVICE COVERPLATES IN PATIENT CARE AREAS. ALSO,

MARK INSIDES OF ALL DEVICE BOXES W ITH PANEL AND CIRCUIT

NUMBER.

D. LOCATE CHAIN-HUNG INDUSTRIAL FIXTURES IN MECHANICAL ROOMS TO

AVOID DUCTW ORK AND PIPING, TO MAXIMIZE AVAILABLE LIGHT. SPACE

AROUND EQUIPMENT, AIR HANDLERS, ETC. TO PROVIDE ADEQUATE

LIGHTING TO ALL AREAS OF ROOM. PROVIDE ADDITIONAL FIXTURES OF

SAME TYPE AS NEEDED TO FULFILL THIS REQUIREMENT.

E. LOCATE EXIT SIGNS FOR MAXIMUM VIEW ING AREA TO IDENTIFY EGRESS

PATHS AS INDICATED ON PLANS. COORDINATE LOCATIONS SUCH THAT

ARCHITECTURAL FEATURES OR EQUIPMENT FROM OTHER TRADES DO

NOT OBSTRUCT VIEW .

F. W HERE EXIT SIGNS OR EMERGENCY BATTERY PACKS ARE PROVIDED,

THEY SHALL BE CONNECTED TO AN UNSW ITCHED LINE.

G. LUMINAIRES INDICATED W ITH MULTI-LEVEL SW ITCHING SHALL HAVE

SIMILAR LAMPS CONTROLLED TOGETHER, I.E. INBOARD AND OUTBOARD

LAMPS OR RIGHT AND LEFT HAND LAMPS.

H. ALL LIGHTING FIXTURE LENSES, PARABOLIC LOUVERS, DOW NLIGHTING

ALZAK CONES AND "PARACUBE" LOUVERS SHALL BE HANDLED W ITH

COTTON GLOVES DURING INSTALLATION AND LAMPING TO AVOID

FINGERPRINTS OR DIRT DEPOSITS. IT IS PREFERRED THAT FIXTURES

BE SHIPPED AND INSTALLED W ITH CLEAR PLASTIC BAGS TO PROTECT

LOUVERS. AT CLOSE OF PROJECT, AND AFTER CONSTRUCTION AIR

FILTERS ARE CHANGED, REMOVE BAGS. ANY LOUVER OR CONE

SHOW ING DIRT OR FINGER PRINTS SHALL BE CLEANED W ITH SOLVENT

RECOMMENDED BY THE MANUFACTURER, OR REPLACED AS

NECESSARY IN ORDER TO TURN OVER TO THE OW NER NEW FIXTURES

AT OCCUPANCY.

I. RECESSED LUMINAIRES SHALL BE SECURED SUCH THAT THE FORCE

REQUIRED INSERTING LAMPS, TRIMS, LENSES, LOUVERS, OR DOOR

FRAMES DOES NOT SHIFT HOUSING. ALL TRIMS SHALL BE COMPLETELY

FLUSH W ITH FINISHED CEILINGS AT COMPLETION OF CONSTRUCTION.

J. CONTRACTOR SHALL PROVIDE UNSW ITCHED CONDUCTOR TO ALL EXIT

SIGNS, EMERGENCY INVERTER BATTERY PACKS, AND NIGHT LIGHTS AS

REQUIRED.

TAGGED NOTES

P16 ROUTE 1 #10 GROUND CONDUCTOR IN 1/2'' CONDUIT CONTINUOUSLY

AROUND ROOM (FULL CIRCLE) CONNECTING TO ALL PANELBOARD

GROUND BARS IN ROOM AS REQUIRED BY N.E.C. #517.14. CONTRACTOR

SHALL ALSO SUBMIT DETAILED ''DIMENSIONED'' SHOP DRAWINGS OF

ELECTRIC ROOMS INDICATING PANELBOARD LOCATIONS,

TRANSFORMER LOCATIONS, DISCONNECT SWITCHES, ETC.

P26 REMOVE EXISTING POWER PANEL INDICATED AND PANEL FEED

COMPLETELY BACK TO SOURCE. FIELD VERIFY IF PANEL HAS ANY

DEVICES, LIGHTS, ETC. ON CIRCUITS THAT ARE TO REMAIN. RE-ROUTE

THESE CIRCUITS TO EXISTING/NEW PANELS THAT ARE IN THE SAME

AREA AS REQUIRED (UTILIZE SPACES/SPARES IN THESE PANELS AS

NECESSARY). CONTRACTOR SHALL CAREFULLY DETERMINE EXTENT OF

WORK PRIOR TO DEMOLITION OF THE PANEL/PANEL FEEDER. REFER TO

PANEL DEMOLITION DETAIL ON ES802 AND POWER RISER ON ES601.

2' 4' 16'8'0

1/4" = 1'-0"

12'1'

SCALE: 1/4" = 1'-0"

ENLARGED THIRD FLOOR "3C" ELECTRICAL

ROOM 300 - ELECTRICAL EXISTING

2' 4' 16'8'0

1/4" = 1'-0"

12'1'

SCALE: 1/4" = 1'-0"

ENLARGED THIRD FLOOR "3B" ELECTRICAL

ROOM 346 - ELECTRICAL EXISTING

GENERAL NOTES (CABLING):

A. ROUTE ALL NEW DATA / VOICE / CCTV CABLING FROM NEW DEVICES ON

PROJECT TO THE NEW 'IT' CLOSET.

B. ROUTE ALL OTHER LOW VOLTAGE SYSTEM CABLING TO NEW 'BIOMED'

CLOSET

SPC

120V BRANCH

CIRCUIT

W IRING IN CONDUIT

PER NURSE CALL

MANUFACTURERS

RECOMMENDATIONS

READING PATIENT

LIGHT FIXTURES

TYPE "H"

CURBELL #LVC-2000-004 DIMMING RELAY

PROVIDED AND INSTALLED BY THIS

CONTRACTOR. MOUNT IN 5-GANG MASONRY

BOX AT THE HEADW ALL (ABOVE SUSPENDED

CEILING) AS REQUIRED TO CONTROL

HEADW ALL DOW NLIGHT UNITS.

NURSE CALL

PATIENT

STATION

13100 watertown plank road suite 200 elm grove, wi 53122

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

Nagel Architects + Engineers project number:

BLDG 500 RENOVATE 3A 613-19-100

19025

CMTA CONSULTING ENGINEERS, INC.

10411 MEETING STREET,

PROSPECT, KY 40059

(502)326-3085

VOLUME AC

U s e rs

\b k a rc h e r\

D o c u m e n ts

\V M

W V

-0 -E

-R b k a rc h e rR U

V A

B .r v t

/5

/2

:2

:0

P

M

ES701

ELECTRICAL SCHEDULES

510 BUTLER AVENUE MARTINSBURG, WV 25405

04/07/2021 PDY BBK

BID DOCUMENTS

FULLY

SPRINKLERED

ELEC - LUMINAIRE SCHEDULE 3A

TYPE DESCRIPTION BASIS OF DESIGN EQUAL MANUFACTURERS MOUNTING LAMPS / CCT MINIMUM LUMENS

MAXIMUM

WATTAGE VOLTAGE REMARKS

A1 2X4 LED FLAT PANEL, LOW OUTPUT METALUX #24FPX-31-L835-GL-HCD LITHONIA EQUAL,

APPROVED EQUAL

LED/3500K 3100 LUMENS 59 277

A1F 2X4 LED FLAT PANEL, LOW OUTPUT, WITH DRYWALL FRAME

KIT

METALUX #24FPX-31-L835-GL-HCD-DF-24W-U LITHONIA EQUAL,

APPROVED EQUAL

LED/3500K 3100 LUMENS 59 120

A2 2X4 LED FLAT PANEL, MEDIUM OUTPUT METALUX #24FPX-47-L835-GL-HCD LITHONIA EQUAL, APPROVED EQUAL

LED/3500K 4700 LUMENS 59 277

A3 2X4 LED FLAT PANEL, HIGH OUTPUT METALUX #24FPX-64-L835-GL-HCD LITHONIA EQUAL,

APPROVED EQUAL

LED/3500K 6400 LUMENS 59 120

B1 2X2 LED FLAT PANEL, LOW OUTPUT WITH INTERNAL

GASKET KIT

METALUX #22FPX-32-L835-GL-HCD LITHONIA EQUAL,

APPROVED EQUAL

LED/3500K 3200 LUMENS 59 277

B1F 2X2 LED FLAT PANEL, HIGH OUTPUT WITH DRYWALL TRIM

KIT AND WITH INTERNAL GASKET KIT

METALUX # 22FPX-42-L835-GL-HCD-DF-22W-U LITHONIA EQUAL,

APPROVED EQUAL

LED/3500K 3200 LUMENS 59 277

D3-10 3" RECESSED ADJUSTABLE LED CAN LIGHT LUMENPULSE #LACS-A-120-L10-DTWP-CR90-NFR-RD-WH-DA-IC GOTHAM EQUAL, APPROVED EQUAL

LED/3500K 1000 LUMENS 37 277

D4-15 4" RECESSED LED CAN LIGHT PORTFOLIO #LD4B-15-D010-EU4B-1020-835-4LBM-1H LITHONIA EQUAL, APPROVED EQUAL

LED/3500K 1500 LUMENS 37 277

D4-15G 4" RECESSED LED CAN LIGHT W/GASKET KIT PORTFOLIO #LDS4B-15-D010-EU4B-1020-835-LGSKT4IP66 LITHONIA EQUAL, APPROVED EQUAL

LED/3500K 1500 LUMENS 37 277

D6-20 6" RECESSED LED CAN LIGHT PORTFOLIO #LD6B-20-D010-EU6B-1020-835-6LBM-1H LITHONIA EQUAL, APPROVED EQUAL

LED/3500K 2000 LUMENS 37 277

DS-10 6" RECESSED LED SHOWER CAN LIGHT HALO #SLD612-8-35-WH-JB LITHONIA EQUAL,

APPROVED EQUAL

LED/3500K 1000 LUMENS 37 277

F1 LED ROUND STRIP FIXTURE WITH LENS METALUX #4SNLED-LD5-41SL-LW-L835-HCD-1-U-AYC-CHAIN/SET LITHONIA EQUAL, APPROVED EQUAL

LED/3500K 4100 LUMENS 59 277

H 4" RECESSED LED READING LIGHT PORTFOLIO # LDA4A-13-8-35-D010TE/4LAL1-HB26 LITHONIA EQUAL, APPROVED EQUAL

LED/3500K 1300 LUMENS 37 277

HG 4" RECESSED LED READING LIGHT W/GASKET KIT PORTFOLIO # LDA4A-13-8-35-D010TE/4LAL1-HB26-LGSKT4IP66 LITHONIA EQUAL, APPROVED EQUAL

LED/3500K 1300 LUMENS 37 277

P2 DECORATIVE PENDENT LIGHTOLIER #6R-N-C6L-25-8-35-M-Z10-U-D6A03 LITHONIA EQUAL,

APPROVED EQUAL

LED/3500K 1000 LUMENS 11 277 FIXTURE FINISHES AS SELECTED BY ARCHITECT

SL1 LED RECESSED STRIP FIXTURE ALW #LP1RWWT LITHONIA EQUAL,

APPROVED EQUAL

LED/3500K 1000 LUMENS 51 277

ST RECESSED AMBER STEP NIGHT LIGHT FAIL-SAFE #MSN-UNV-W LITHONIA EQUAL,

APPROVED EQUAL

LED/3500K AMBER LIGHTS 59 277 FIXTURE FINISHES AS SELECTED BY ARCHITECT

V1 LED WALL MOUNT VAINTY FIXTURE, UL DAMP LOCATION

LABELLED

LEGION #244L-2-1-LL1-35-DL-AM ACUITY EQUAL, APPROVED

EQUAL

LED/3500K 1000 LUMENS 59 277 FIXTURE FINISHES AS SELECTED BY ARCHITECT

X1 EXIT SIGN, SINGLE FACE, DIRECTION ARROWS AS

INDICATED

SURE-LITES #ES6-X LITHONIA EQUAL,

APPROVED EQUAL

LED/3500K 2 277

X2 EXIT SIGN, DUAL FACE, DIRECTION ARROWS AS INDICATED SURE-LITES #ES6-X LITHONIA EQUAL, APPROVED EQUAL

LED/3500K 2 277

GENERAL NOTES (LUMINAIRE SCHEDULE):

A. ALL LUMINAIRES AND COMPONENTS SHALL BE UL LISTED.

B. W HERE LUMINAIRES ARE SHOW N SPLIT-W IRED (HALF EMERGENCY

POW ER/ HALF NORMAL POW ER) ON FLOOR PLANS, LUMINAIRES SHALL

BE PROVIDED W ITH MULTIPLE ELECTRONIC BALLASTS FOR MULTIPLE

POW ER CIRCUITS AS INDICATED ON FLOOR PLANS.

C. PROVIDE BALLASTS FOR FIXTURE LAMP SW ITCHING AS INDICATED ON

LIGHTING FLOOR PLANS. W HERE A SINGLE FIXTURE IS POW ERED FROM

NORMAL AND EMERGENCY POW ER, HALF OF THE LAMPS W ITH A

MINIMUM OF TW O LAMPS SHALL BE ON EMERGENCY POW ER.

D. CONTRACTOR SHALL FOCUS, AIM AND ADJUST LUMINAIRES UNDER THE

SUPERVISION AND DIRECTION OF THE ENGINEER AND ARCHITECT.

ALLOW LABOR FOR FINAL FOCUS AND ADJUSTMENTS AFTER DARK.

LIFTS AND SCAFFOLDING SHALL BE AVAILABLE.

E. ALL LAY-IN FIXTURES SHALL BE PROVIDED W ITH SCREW ON HOLD

DOW N CLIPS AND MAXIMUM 6'-0" LONG FLEXIBLE CONDUIT W HIPS.

F. W HERE LIGHT FIXTURES ARE SHOW N ON PLANS TO BE CONTROLLED

W ITH A DIMMER SW ITCH, COORDINATE EXACT DIMMER TYPE W ITH

LIGHT FIXTURE MANUFACTURER TO ENSURE COMPATIBILITY.

ELEC - EQUIPMENT CONNECTION SCHEDULE 3A

EQUIP ID DESCRIPTION DISCONNECT MEANS VOLTAGE POLES HP POWER (kVA) MCA

EF-70-A EXHAUST FAN VFD FURNISHED BY MECHANICAL CONTRACTOR 480 3 2 2.80

EF-70-B EXHAUST FAN VFD FURNISHED BY MECHANICAL CONTRACTOR 480 3 2 2.80

EF-71-A EXHAUST FAN VFD FURNISHED BY MECHANICAL CONTRACTOR 480 3 5 6.30

EF-71-B EXHAUST FAN VFD FURNISHED BY MECHANICAL CONTRACTOR 480 3 5 6.30

SCALE: NONE

PATIENT READING LIGHT CONTROL

SCHEMATIC

13100 watertown plank road suite 200 elm grove, wi 53122

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

Nagel Architects + Engineers project number:

BLDG 500 RENOVATE 3A 613-19-100

19025

CMTA CONSULTING ENGINEERS, INC.

10411 MEETING STREET,

PROSPECT, KY 40059

(502)326-3085

VOLUME AC

U s e rs

\b k a rc h e r\

D o c u m e n ts

\V M

W V

-0 -E

-R b k a rc h e rR U

V A

B .r v t

/5

/2

:2

:0

P

M

ES702

PANELBOARD SCHEDULES

510 BUTLER AVENUE MARTINSBURG, WV 25405

04/07/2021 PDY BBK

BID DOCUMENTS

FULLY

SPRINKLERED

PANELBOARD SHALL BE SQUARE-D, TYPE "NF" OR EQUAL WITH 42-POLES.

1. REFER TO POWER RISER FOR CIRCUIT BREAKER SIZE AND CONDUIT / WIRING SIZES

NOTES: WHERE NOT LISTED, WIRE AND CONDUIT SHALL BE BE MINIMUM PER SPECIFICATIONS. SPARE BREAKERS TO BE 20A/1P.

TOTAL ESTIMATED DEMAND CURRENT: 65 A

REC 12060 VA 91.46% 11030 VA TOTAL CONNECTED CURRENT: 67 A

LTNG 1754 VA 100.00% 1754 VA TOTAL ESTIMATED DEMAND: 54284 VA

EQUIP 41500 VA 100.00% 41500 VA TOTAL CONNECTED LOAD: 55314 VA

LOAD CLASSIFICATION CONNECTED LOAD DEMAND FACTOR ESTIMATED DEMAND PANEL TOTALS

TOTAL CURRENT (A): 64 A 69 A 67 A

TOTAL LOAD (kVA): 17.8 kVA 19.1 kVA 18.5 kVA

SPARE -- -- -- 20 1 41 0.0 0.0 42 1 20 -- -- -- SPARE

SPARE -- -- -- 20 1 39 0.0 0.0 40 1 20 -- -- -- SPARE

SPARE -- -- -- 20 1 37 0.0 0.0 38 1 20 -- -- -- SPARE

SPARE -- -- -- 20 1 35 0.0 0.0 36 1 20 -- -- -- SPARE

SPARE -- -- -- 20 1 33 0.0 0.0 34 1 20 -- -- -- SPARE

SPARE -- -- -- 20 1 31 0.0 0.0 32 1 20 -- -- -- SPARE

SPARE -- -- -- 20 1 29 0.0 0.0 30 1 20 -- -- -- SPARE

SPARE -- -- -- 20 1 27 0.0 0.0 28 1 20 -- -- -- SPARE

SPARE -- -- -- 20 1 25 0.0 0.0 26 1 20 -- -- -- SPARE

SPARE -- -- -- 20 1 23 0.0 0.0 24 1 20 -- -- -- SPARE

SPARE -- -- -- 20 1 21 0.0 0.0 22 1 20 -- -- -- SPARE

SPARE -- -- -- 20 1 19 0.0 0.0 20 1 20 -- -- -- SPARE

SPARE -- -- -- 20 1 17 0.0 0.0 18 1 20 -- -- -- SPARE

SPARE -- -- -- 20 1 15 0.0 0.0 16 1 20 -- -- -- SPARE

SPARE -- -- -- 20 1 13 0.0 0.0 14 1 20 -- -- -- SPARE

SPARE -- -- -- 20 1 11 0.0 0.0 12 1 20 -- -- -- SPARE

SPARE -- -- -- 20 1 9 0.0 0.0 10 1 20 -- -- -- SPARE

SPARE -- -- -- 20 1 7 0.0 17.8 8

SPARE -- -- -- 20 1 5 0.0 18.5 6

LTNG WORK 3A-315 20 1 3 1.8 17.3 4

3 0 1 T-EP-3A

LTNG ICU PATIENT ROOMS 20 1 1 0.0 0.0 2 1 20…