This document provides details for a federal construction contract opportunity to renovate buildings 3A and 3B of the VA Medical Center in Martinsburg, West Virginia. The Department of Veterans Affairs seeks a prime contractor for project no. 613-19-100 with an estimated cost between $10-20 million to provide general construction and alteration services, including millwork, equipment installation, and interior finishes. The solicitation is a 100% set-aside for Service-Disabled Veteran Owned Small Businesses. Interested firms must be approved in NAICS 236220 for general building construction with a size standard of $39.5 million. The pre-bid site visit will be held on June 9, 2021, with any questions due by June 17th. Sealed bids for the opportunity are due on July 14, 2021. The awarded contractor must be registered on SAM.gov and VetBiz.gov and in compliance with VETS-4212.
View the file
Other files
Show all 38
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Bldg. 500 – Renovate 3B 05-01-15 Project No. 613-19-101
12 31 00 - 1 Submission Bid Documents July 16, 2020
SECTION 12 31 00
MANUFACTURED METAL CASEWORK
PART 1 - GENERAL
1.1 DESCRIPTION:
A. This section specifies metal casework, VA standard cabinets and related accessories, including base cabinets, wall cabinets, and full height cabinets.
B. Medical Storage cabinets and PPE cabinets
1.2 RELATED WORK:
A. Sealants: Section 07 92 00, JOINT SEALANTS.
B. Color of Casework Finish: Section 09 06 00, SCHEDULE OF FINISHES.
C. Resilient Base: Section 09 65 13, RESILIENT BASE AND ACCESSORIES.
D. Backing Plates for Wall Mounted Casework: Section 09 22 16, NON-STRUCTURAL METAL FRAMING.
E. Standard Manufactured Wood Casework: Section 12 32 00, MANUFACTURED WOOD
CASEWORK.
F. Countertop Construction and Materials and Items Installed in
Countertops: Section 12 36 00, COUNTERTOPS.
G. Plumbing Requirements Related to Casework: Division 22, PLUMBING.
H. Electrical Lighting and Power Requirements Related to Casework:
Division 26, ELECTRICAL.
1.3 QUALITY ASSURANCE:
A. Approval by Contracting Officer Representative (COR) is required of manufacturer and installer based upon certification of qualifications specified.
B. Manufacturer’s Qualifications:
1. Manufacturer is regularly engaged in design and manufacture of metal of scope and type similar to requirements of this project for a period of not less than five (5) years.
2. Manufacturer has successfully completed at least three (3) projects of scope and type similar to requirements of this project.
3. Submit manufacturer’s qualifications and list of projects.
C. Installer Qualifications:
1. Installer has completed at least three (3) projects in least five (5) years in which these products were installed.
2. Submit installer qualifications.
12 31 00 - 2 Submission Bid Documents July 16, 2020
1.4 SUBMITTALS:
A. Submit in accordance with Section 01 33 23, SHOP DRAWINGS, PRODUCT
DATA, AND SAMPLES.
B. Certificates:
1. Manufacturer's Certificate of qualifications specified.
2. Certificate of installer’s qualifications specified.
C. Manufacturer's Literature and Data:
1. Brochures showing name and address of manufacturer, and catalog or model number of each item incorporated into the work.
2. Manufacturer's illustration and detailed description.
3. List of deviations from contract specifications.
4. Locks, each kind.
D. Shop Drawings (1/2 Full Scale):
1. Showing details of casework construction, including kinds of materials and finish, hardware, accessories and relation to finish of adjacent construction, including specially fabricated items or components.
2. Fastenings and method of installation.
3. Location of service connections and access.
E. Samples:
1. Metal plate, 152 mm (6 inch) square, showing chemical resistant finish, in each color.
F. Manufacturer’s warranty.
1.5 WARRANTY:
A. Construction Warranty: Comply in accordance with contract.
B. Manufacturer Warranty: Manufacturer shall warranty their wood casework for a minimum of five (5) years from date of installation and final acceptance by the Government. Submit manufacturer warranty.
1.6 APPLICABLE PUBLICATIONS:
A. Publications listed below form a part of this specification to extent referenced. Publications are referenced in the text by basic designation only.
B. American Society for Testing and Materials (ASTM):
A36/A36M-14.............Carbon Structural Steel
A240/A240M-14...........Chromium and Chromium-Nickel Stainless Steel
Plate, Sheet, and Strip for Pressure Vessels and for General Applications
12 31 00 - 3 Submission Bid Documents July 16, 2020
A283/A283M-13...........Low and Intermediate Tensile Strength Carbon
Steel Plates
A568/A568M-14...........Steel, Sheet, Carbon and High-Strength, Low-
Alloy Hot-Rolled and Cold-Rolled, General
Requirements
A794/A794M-12...........Standard Specification for Commercial Steel
(CS), Sheet, Carbon (0.16% Maximum to 0.25%
Maximum) Cold Rolled
B456-11.................Electrodeposited Coatings of Copper Plus Nickel
Plus Chromium and Nickel Plus Chromium
C1036-11(R2012).........Flat Glass
C1036-12e1..............Heat-Strengthened and Fully Tempered Flat Glass
C1172-14................Laminated Architectural Flat Glass
C. American National Standard Institute:
Z97.1-09(R2010).........Safety Glazing Material used In Buildings
D. Builders Hardware Manufacturers Association (BHMA):
A156.1-13...............Butts and Hinges
A156.9-10...............Cabinet Hardware
A156.5-14...............Auxiliary Locks and Associated Products
A156.11-14..............Cabinet Locks
A156.16-13..............Auxiliary Hardware
E. American Welding Society (AWS):
D1.1/D1.1M-10...........Structural Welding Code Steel
D1.3/D1.3M-05(R2008)....Structural Welding Code Sheet Steel
F. National Association of Architectural Metal Manufacturers (NAAMM):
AMP 500 Series..........Metal Finishes Manual
G. U.S. Department of Commerce, Product Standard (PS):
PS 1-09.................Construction and Industrial Plywood
H. Underwriters Laboratories Inc. (UL):
325-06(R2013)...........Door, Drapery, Gate, Louver, and Window
Operators and Systems
437-08(R2013)...........Key Locks
I. Federal Specifications (Fed. Spec.):
A-A-55615...............Shield, Expansion; Nail Expansion (Wood Screw and Lag Bolt Self-Threading Anchors)
J. Scientific Equipment and Furniture Association (SEFA):
2.3-10..................Installation of Scientific Laboratory Furniture and Equipment
12 31 00 - 4 Submission Bid Documents July 16, 2020
PART 2 - PRODUCTS
2.1 MATERIALS:
A. Basis of design:
1. Meds Storage Cabinets, Semi-Recessed, push button lock with secondary push button narcotic lock and drop down work surface, OD:
23.125”W x 25.125”H x 7”D; ID: 21.125”W x 23.125”H x 7”D; Weight 35 lbs.; Housing Construction: 14 Gauge (0.075) Steel; Door
Construction: 18 Gauge (0.048); Lock outer Cabinet: Keyless; Lock inner narcotic: Keyless; Finish: powder coat and laminate door, or equal approved. Alternative product as follows:
Bidding on:
Manufacturer Name: _______________________
Brand: __________________________________
No.: ____________________________________
2. PPE Cabinets, Semi-Recessed, contents face masks, glove boxes and bulk pack insolation gowns, OD: 26”W x 29”H x 5”D; ID: 24”W x 27”H x
5”D; Weight: 40 lbs.; Housing Construction: 14 Gauge (0.75) Steel;
Door Construction: 18 Gauge (0.048); Lock: Available key or keyless;
Finish: Powder coat and laminate, or equal approved. Alternative product as follows:
Bidding on:
Manufacturer Name: _______________________
Brand: __________________________________
No.: ____________________________________
B. Sheet Steel:
1. ASTM A794/A794M, cold rolled, Class 1 finish, stretcher leveled.
2. Other types of cold rolled steel meeting requirements of
ASTM A568/A568M are acceptable for concealed parts.
C. Stainless Steel: ASTM A240/A240M, Type 302B.
F. Glazing Cushions:
1. Channel shaped, of rubber, vinyl or polyethylene plastic, with vertical flanges not less than 2 mm (3/32 inch) thick and horizontal web 3 mm (1/8 inch) thick.
2. Flanges may have bulbous terminals above the glazing heads or terminate flush with top of beads.
H. Fasteners:
12 31 00 - 5 Submission Bid Documents July 16, 2020
1. Exposed to View: Chrome plated steel or stainless steel, or finished to match adjacent surface.
2. Provide round head or countersunk fasteners where exposed in cabinets.
3. Expansion Bolts: Fed Spec. A-A-55615. Do not provide lead or plastic shields.
4. Nuts: Fed Spec FF-N-836. Type III, Style 15 where exposed.
5. Sex Bolts: Capable of supporting twice the load.
2.2 MANUFACTURED PRODUCTS:
A. When two (2) or more units are required, use products of one (1) manufacturer.
B. Manufacturer of casework assemblies is to assume complete responsibility for the final assembled unit.
C. Provide products of a single manufacturer for parts which are alike.
2.3 CASEWORK FABRICATION:
A. General:
1. Welding: Comply with AWS Standards D1.1/D1.1M and D1.3/D1.3M.
2. Reinforce with angles, channels, and gussets to support intended loads, notch tightly, fit and weld joints.
3. Constructed of sheet steel, except where reinforcing required.
B. Minimum Steel Thickness:
0.89 mm (0.035 inch) (20 gage)
Drawer fronts, backs, bodies, closure plates or scribe and filler strips less than 75 mm (3 inches) wide, sloping top, shelf reinforcement channel and shelves. Toe space or casework soffits and ceilings under sloping tops.
1.20 mm (0.047 inch) (18 gage)
Base pedestals, casework top sides, back, and bottom panels, closure scribe and filler strips 75 mm (3 inches) or more. Reinforcement for drawers with locks. Tables legs, spreaders and stretchers, when fabricated of cold rolled tubing. Metal for desks;
except legs and aprons. Door exterior and interior panels, flush or glazed. Cross rails of base units.
Front bottom rails, back bottom rails; rails shall be 1.49 mm (0.059 inch) (16 gage) thick. Uprights or posts. Top corner gussets.
1.49 mm (0.059 inch) (16 gage)
Aprons, apron division, reinforcing gussets, table legs, desk legs and aprons, spreaders and stretchers when formed without welding. Toe base gussets, drawer slides, and other metal work. Front top rails and back rails except top back rails shall be 1.2 mm (0.047 inch) (18 gage) thick.
12 31 00 - 6 Submission Bid Documents July 16, 2020
1.88 mm (0.074 inch) (14 gage)
Drawer runners door tracks.
2.64 mm (0.104 inch) (12 gage)
Base unit bottom corner gussets and leg sockets.
3 mm (0.12 inch) (11 gage)
Reinforcement for hinge reinforcement inside doors and cabinets.
C. Casework Construction:
1. Welded assembly.
2. Fabricate with enclosed uprights or posts full height or width at front. Include sides, backs, bottoms, soffits, ceilings under sloping tops, headers and rail, assembled to form an integral unit.
3. Form sides to make rabbeted stile, 19 to 28 mm (3/4 to 1-1/8 inch) wide, closed by channel containing shelf adjustment slots.
4. Make bottom of walls units flush, double panel construction.
5. Make top and cross rails of "U" shaped channel.
6. Provide enclosed backs and bottoms in cabinets, including drawer units.
7. Provide finish panel on exposed cabinet backs.
8. Do not install screws and bolts in construction or assembly of casework, except to secure hardware, applied door stops, accessories, removable panels, and where casework is required to be fastened, end to end or back to back.
9. Fabricate casework, except benches, and desks with finished end panels.
10. Close flush exposed soffits of wall hung shelving, knee spaces in counters, and toe spaces at bases.
14. Provide reinforcing for hardware.
15. Size Dimensions:
a. Use dimensions shown on construction documents or within tolerances specified.
b. Tolerance:
Depth Nominal Dim
(mm (inch))
Plus
Tolerance
(mm (inch))
Minus
Tolerance
(mm (inch))
Depth 305 (12) 1 (25) 0 (0)
12 31 00 - 7 Submission Bid Documents July 16, 2020
Width - - 0 (0) 1 (25)
Wall
Hung
Cabinet
Height - - 1 (25) 1 (25)
Counter
Mounted
Cabinet
Height - - 1 (25) 1 (25)
Floor
Standing
Cabinet
Height - - 1 (25) 0 (0)
1) Manufacturer's Tolerance for the same Length, Depth or Height of Cabinet: Not to exceed 1.58 mm (0.0625 inches).
E. Doors:
1. Hollow metal type, flush and glazed doors not less than 16 mm
(5/8 inch) thick.
2. Fabricate flush metal doors of two (2) panels formed into pans with corners welded and ground smooth. Provide flush doors with a sound deadening core.
3. Fabricate glazed metal doors with reinforced frame and construct either from one (1) piece of steel, or have separate stiles and rails mitered and welded at corners, and welds ground smooth.
a. Secure removable glazing members with screws to back of doors.
b. Install glass in rubber or plastic glazing channels.
4. Provide sheet steel hinge reinforcement inside doors.
6. Doors removable without use of tools except where equipped with locks.
H. Shelves:
1. Capable of supporting an evenly distributed minimum load of
122 kg per square meter (25 pounds per square foot) without visible distortion.
2. Flange shelves down 19 mm (3/4 inch) on edges, with front and bearing edges flanged back 13 mm (1/2 inch).
4. Weld shelves to metal back and ends unless shown on construction documents as adjustable.
5. Provide means of positive locking shelf in position, and to permit adjustment without use of tools.
12 31 00 - 8 Submission Bid Documents July 16, 2020
I. Closures and Filler Strips at Pipe Spaces:
1. Flat steel strips or plates.
2. Openings less than 203 mm (8 inches) wide: 1.2 mm (0.047 inch) thick.
3. Openings more than 203 mm (8 inches wide 0.9 mm (0.359 inches) wide.
2.4 ACCESSORIES:
A. Card or Label Holders for Shelves:
1. Fabricate of 0.6 mm (0.0239 inch) thick steel approximately 125 mm
(5 inches) long, or continuous where shown on construction documents, having top and bottom edges bent over on face and welded to shelf.
2. Finish exposed surfaces in same color as shelf.
B. Shadow Boards:
1. Plywood of size and thickness shown on construction documents with exposed edges chamfered.
2. Secure boards to back of exterior metal doors and cabinet back with screws.
3. Use pivot top and bottom hinges on intermediate boards with pulls on each leaf.
4. Paint exposed surfaces of shadow boards two shop coats of white semi-gloss paint.
C. Dispensing Trays and Bins
1. Design trays and bins to fit cabinets where shown on construction documents.
2. Fabricate of steel, polypropylene, fiberglass reinforced polyester resin, or other suitable material.
3. Lock securely in place without the use of tools.
4. Fit at angle to provide gravity feed where shown on construction documents.
5. Dispensing Trays:
a. Equip trays with two (2) longitudinal dividers adjustable to three (3) positions.
b. Approximate dimensions: 152 mm (6 inches) in width 76 mm
(3 inches) in depth, and length to suit cabinets depth furnished.
6. Dispensing Bins:
a. Open front, except for retaining rim.
12 31 00 - 9 Submission Bid Documents July 16, 2020
b. Approximate dimensions: 152 mm (6 inches) in width, 127 mm
(5 inches) in depth, and length to suit cabinets furnished.
2.5 HARDWARE:
A. Factory installed.
B. Exposed hardware, except as specified otherwise, satin finished chromium plated brass or nickel plated brass or anodized aluminum.
C. Cabinet Locks:
1. Where locks are shown on construction documents.
2. Locked pair of hinged door over 915 mm (36 inches) high:
a. ANSI/BHMA A156.5, similar to E0261, Key one (1) side.
b. On active leaf use three (3) point locking device, consisting of two (2) steel rods and lever controlled cam at lock, to operate by lever having lock cylinder housed therein.
c. On inactive leaf provide dummy lever of same design.
d. Provide keeper holes for locking device rods and cam.
3. Key locks differently for each type casework and master key for each service, such as Nursing Units, Psychiatric, Administrative, Pharmacy.
a. Key drug locker inner door different from outer door.
b. Furnish two (2) keys per lock.
c. Furnish six (6) master keys per service or Nursing Unit.
4. Marking of Locks and Keys:
a. Name of manufacturer, or trademark which can readily be identified legibly marked on each lock and key change number marked on exposed face of lock.
b. Key change numbers stamped on keys.
c. Key change numbers to provide sufficient information for manufacturer to replace key.
D. Cabinet Hardware: ANSI BHMA A156.9.
1. Door in seismic zones: B03352.
a. Do not provide thumb latch on doors equipped with three (3) point locking device.
b. Provide lever operated two (2) point latching device on paired doors over 915 mm (36 inches) high if three (3) point locking or latching device is not used.
2. Cabinet Door Catch:
b. Omit on doors with locks.
3. Butt Hinges:
12 31 00 - 10 Submission Bid Documents July 16, 2020
a. B01351, minimum 1.8 mm (0.072 inch) thick chrome plated steel leaves.
b. Minimum 3.5 mm (0.139 inch) diameter stainless steel pins.
c. Full mortise type, five (5) knuckle design with 63 mm
(2 1/2 inch) high leaves and hospital type tips.
d. Two (2) hinges per door except use three (3) hinges on doors
1220 mm (48 inches) and more in height. Use stainless steel leaves for tilting bin doors.
f. Do not weld hinges to doors or cabinets.
4. Pivot hinges: ANSI/BHMA A156.1 A875B.
5. Shelf Supports:
a. Install in casework where adjustable shelves are noted on construction documents.
b. Adjustable Shelf Standards: B04061 with shelf rest B04081.
c. Vertical Slotted Shelf Standard: B04102 with shelf brackets
B04112 sized for shelf depth.
6. Auxiliary Hardware: ANSI A156.16.
7. Door silencers: LO3011 or LO3031.
a. Install two (2) rubber bumpers each door.
b. Silencers set near top and bottom of jamb.
8. Closet Bar: L03131 chrome finish of required length.
2.6 METAL FINISHES:
A. Comply with NAAMM AMP 500 series and as specified.
B. Steel Cabinets including Closures and Filler Strips:
1. Acid resisting finish except hardware and stainless steel.
2. After fabrication of cabinet submerge in a degreasing bath, and thoroughly rinse to remove dirt and grease, and other foreign matter.
3. Apply non-metallic phosphate coating, then finish with baked-on acid resisting enamel not less than 1 mil (0.001 inch) thick.
4. Finish resistant to action of the following reagents when 0.5 cm3
(10 drops) are applied to the surface and left open to the atmosphere for period of one (1) hour.
Hydrochloric Acid 37 percent Ethyl Alcohol
Phosphoric Acid 75 percent Methylethyl Keytone
Sulfuric Acid 25 percent Acetone
Glacial Acetic Acid Ethyl Acetate
12 31 00 - 11 Submission Bid Documents July 16, 2020
Sodium Hydroxide 10 percent Ethyl Ether
Sodium Hydroxide (concentrated) Carbon Tetrachloride
Hydrogen Peroxide 5 percent Xylene
Formaldehyde 37 percent Phenol 85 Percent
5. Color of finish is specified in Section 09 06 00, SCHEDULE FOR
FINISHES.
C. Aluminum: Chemically etched medium matte, clear anodic coating, Class II, Architectural, 0.4 mils (0.0004 inches) thick.
2.7 VA STANDARD CABINETS:
A. Hospital Casework, including metal casework of the following types:
1. Wardrobe Cabinet, Metal, 5A (VA Standard Detail SD123100-02).
2. Wall Cabinet, Metal, 5B (VA Standard Detail SD123100-01).
2.8 PRODUCTS OF OTHER COMPONENTS DIRECTLY RELATED TO CASEWORK:
A. Refer to Section 07 92 00, JOINT SEALANTS for work related to sealants used in conjunction with joints of countertops, casework systems, and adjacent materials.
B. Refer to Section 09 65 13, RESILIENT BASE AND ACCESSORIES for work related to rubber base adhered to casework systems.
C. Refer to Section 09 22 16, NON-STRUCTURAL METAL FRAMING for backing plates used in conjunction with wall assemblies for the attachment of casework systems.
D. Refer to Section 12 36 00, COUNTERTOPS for work related to plastic laminate, molded resin, and/or shelving used in conjunction with casework systems. When countertop materials are provided by the casework manufacturer, they are to include the following features:
1. Capable of being suspended from vertical support rails or horizontal wall strips or service modules.
2. Provided with rounded corners and impact resistant material on exposed edges.
3. Capable of being easily relocated and installed without tools.
4. Capable of being suspended and easily changed under counter mounted storage units.
5. Provide leveling adjustment capability so units can be brought into a level position.
6. Secured using fasteners. Show detail on shop drawings.
E. Refer to Section 12 36 00, COUNTERTOPS for work related to and integral with countertop systems such as pegboards, funnel and graduate racks.
12 31 00 - 12 Submission Bid Documents July 16, 2020
F. Refer to Division 22, PLUMBING for the following work related to casework systems:
1. Sinks, faucets and other plumbing service fixtures, venting, and piping systems.
2. Compressed air, gas, vacuum and piping systems.
G. Refer to Division 26, ELECTRICAL for the following work related to casework systems:
1. Connections and wiring devices.
2. Connections and lighting fixtures except when factory installed by the manufacturer.
PART 3 - EXECUTION
3.1 COORDINATION:
A. Begin only after work of other trades is complete, including wall and floor finish completed, ceilings installed, light fixtures and diffusers installed and connected, and area free of trash and debris.
B. Verify location and size of mechanical and electrical services as required and perform cutting of components of work installed by other trades.
C. Verify reinforcement of walls and partitions for support and anchorage of casework.
D. Coordinate with other Divisions and Sections of the specification for work related to installation of casework systems to avoid interference and completion of service connections.
3.2 INSTALLATION:
A. Install casework in accordance with manufacturer’s written instructions and per SEFA 2.3 recommendations.
1. Install in available space; arranged for safe and convenient operation and maintenance.
2. Align cabinets for flush joints except where shown otherwise on construction documents.
3. Install with bottom of wall cabinets in alignment and tops of base cabinets aligned level, plumb, true, and straight to a tolerance of
3.2 mm in 2438 mm (1/8 inch in 96 inches).
4. Install corner cabinets with hinges on corner side with filler or spacers sufficient to allow opening of drawers.
B. Support Rails:
12 31 00 - 13 Submission Bid Documents July 16, 2020
1. Install true to horizontal at heights shown on construction documents; maximum tolerance for uneven floors is plus or minus 13 mm (1/2 inch).
2. Shim as necessary to accommodate variations in wall surface not exceeding 5 mm (3/16 inch) at fastener.
C. Wall Strips:
1. Install true to vertical and spaced as shown on construction documents.
2. Align slots to assure that hanging units shall be level.
D. Plug Buttons:
1. Install plug buttons in predrilled or prepunched perforations not used.
2. Use chromium plate plug buttons or buttons finish to match adjacent surfaces.
E. Seal junctures of casework systems with mildew-resistant silicone sealants as specified in Section 07 92 00, JOINT SEALANTS.
3.3. CLOSURES AND FILLER PLATES:
A. Close openings larger than 6 mm (1/4 inch) wide between cabinets and adjacent walls with flat, steel closure strips, scribed to required contours, or machined formed steel fillers with returns, and secured with sheet metal screws to tubular or channel members of units, or bolts where exposed on inside.
B. Secure filler plates to casework top members, unless shown otherwise on construction documents.
C. Secure filler plates more than 152 mm (6 inches) in width top edge to a continuous 25 x 25 mm (1 x 1 inch) 0.889 mm (1/16 inch) thick steel formed steel angle with screws.
D. Install closure strips at exposed ends of pipe space and offset opening into concealed space.
E. Finish closure strips and fillers with same finishes as cabinets.
3.4 FASTENINGS AND ANCHORAGE:
A. Do not anchor to wood ground strips.
B. Provide hat shape metal spacers where fasteners span gaps or spaces.
C. Use 6 mm (1/4 inch) diameter toggle or expansion bolts, or other appropriate size and type fastening device for securing casework to walls or floor. Use expansion bolts shields having holding power beyond tensile and shear strength of bolt and breaking strength of bolt head.
D. Use 6 mm (1/4 inch) diameter hex bolts for securing cabinets together.
12 31 00 - 14 Submission Bid Documents July 16, 2020
E. Use 6 mm (1/4 inch) by minimum 38 mm (1-1/2 inch) length lag bolt anchorage to wood blocking for concealed fasteners.
F. Use not less than No. 12 or 14 wood screws with not less than 38 mm (1
1/2 inch) penetration into wood blocking.
G. Space fastening devices 305 mm (12 inches) on center with minimum of three (3) fasteners in 915 or 1219 mm (3 or 4 foot) unit width.
H. Anchor floor mounted cabinets with a minimum of four (4) bolts through corner gussets. Anchor bolts shall be combined with or separate from leveling device.
I. Secure cabinets in alignment with hex bolts or other internal fastener devices removable from interior of cabinets without special tools. Do not use fastener devices which require removal of tops for access.
J. Where units abut end to end, anchor together at top and bottom of sides at front and back. Where units are back to back, anchor backs together at corners with hex bolts placed inconspicuously inside casework.
K. Where type, size, or spacing of fastenings is not shown or specified on construction documents, show on shop drawings proposed fastenings and method of installation.
3.5 ADJUSTMENTS:
A. Adjust equipment to insure proper alignment and operation.
B. Replace or repair damaged or improperly operating materials, components or equipment.
3.6 CLEANING:
A. Immediately following installation, clean each item, removing finger marks, soil and foreign matter resulting from work of this section.
B. Remove from job site trash, debris and packing materials resulting from work of this section.
C. Leave installed areas clean of dust and debris resulting from work of this section.
3.7 INSTRUCTIONS:
A. Provide operational and cleaning manuals and verbal instructions in accordance with Article INSTRUCTIONS, SECTION 01 00 00, GENERAL
REQUIREMENTS.
B. Provide in service training both prior to and after facility opening.
Coordinate in service activities with COR.
C. Commencing at least seven (7) days prior to opening of facility, provide one (1) 4-hour day of on-site orientation and technical
12 31 00 - 15 Submission Bid Documents July 16, 2020 instruction on use and cleaning procedures application of products and systems specified herein.
- - - E N D - - -