AE501 - rev 1 - with VA red-marks.pdf

PDF 1 MB Posted

Attached to
Y1DA--528A7-20-705 RENOVATE 2nd FLOOR ROME CBOC FOR PACT
Solicitation number
36C24221B0053
Issued by

About this file

This document contains details for a federal construction contract opportunity to renovate the second floor of the Rome, New York VA Community Based Outpatient Clinic for Primary Care following Patient Aligned Care Team guidelines. The renovation project includes abatement of asbestos and hazardous materials, demolition of existing walls, electrical, lighting, ceilings, floors, mechanical equipment and ductwork/piping, and construction of a new Primary Care clinic with exam rooms for primary care, women's health and clinical video telehealth, in addition to procedure room suites, staff and administrative support areas totaling approximately 25,000 square feet. The North American Industry Classification System code is 236220 with a small business size standard of $39.5 million. The construction value is estimated between $5-10 million. The Department of Veterans Affairs Veterans Health Administration VISN 2 will issue an Invitation for Bid on or around July 22, 2021 via beta.SAM.gov.

View the file

Other files

File Type Posted
Amendment 0017.docx DOCX document
Amendment 0016.docx DOCX document
EY121B - Rev 1.pdf PDF
Amendment 0015.docx DOCX document
EP121B - Rev 2.pdf PDF
E-604 - Rev 2.pdf PDF
Amendment 0014.docx DOCX document
AE601 - Rev 2.pdf PDF
EY121C - Rev 1.pdf PDF
08 36 16 Sliding Door and Frames - Rev 1.pdf PDF
E-501 - Rev 1.pdf PDF
E-605 - Rev 1.pdf PDF
EY111 - Rev 1.pdf PDF
EY121A - Rev 1.pdf PDF
AE801 - rev 1.pdf PDF
Amendment 0013.docx DOCX document
AE802 - rev 1.pdf PDF
Amendment 0012.docx DOCX document
EL121C - Rev 1 - 211101.pdf PDF
EL121A - Rev 1 - 211101.pdf PDF
AE701 - rev 2.pdf PDF
AE121.A - rev 1.pdf PDF
RFI - Electric RFI.pdf PDF
EL121B - Rev 1 - 211101.pdf PDF
spec revised section - 09 06 00 Schedule of Finishes - rev 1.pdf PDF
AE121.C - rev 1.pdf PDF
AE121.B - rev 1 - with VA red-marks.pdf PDF
AE405 - Rev 1.pdf PDF
AE404 - Rev 1 - with VA red-marks.pdf PDF
AE406 - Rev 1.pdf PDF
Amendment 0011.docx DOCX document
AE407 - Rev 1.pdf PDF
AE408 - Rev 1.pdf PDF
AE403 - Rev 1.pdf PDF
AE508 - Rev 1.pdf PDF
AE409 - Rev 1.pdf PDF
AE401 - rev 1.pdf PDF
Amendment 0010.docx DOCX document
AE402 - rev 1.pdf PDF
spec added section - 11 73 00 Ceiling Mounted Patient Lift System.pdf PDF
AE507 - rev 1.pdf PDF
AE601 - rev 1.pdf PDF
spec revised section - 10 21 23 Cubicle Curtain Tracks and Curtains - REV 1b.pdf PDF
Asbestos - Lead-based Paint - Regulated Materials - 3-29-2019 report by Skelly and Loy - 92 pages.pdf PDF
spec added section - 08 31 13 Access Doors and Frames.pdf PDF
Amendment 0009.docx DOCX document
AE701 - rev 1.pdf PDF
EL111 - rev 1.pdf PDF
AE702 - rev 1.pdf PDF
Amendment 0008.docx DOCX document
Show 40 more

Latest 50 of 84 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

UL DETAIL W-L-2038 UL DETAIL C-AJ-1254

PARTITION TYPES AND DETAILS

AE501

RENOVATE 2ND FLOOR

ROME CBOC FOR PACT

VA ROME OUTPATIENT CLINIC

ROME, NY

528A7-20-705 o n e e ig h th in ch o n e f o o t

C th re e in ch e s o n e f o o t 6 o n e a n d o n e h a lf in ch e s o n e f o o t o n e in ch o n e f o o t th re e q u a rt e rs in ch o n e f o o t o n e h a lf in ch o n e f o o t th re e e ig h th s in ch o n e f o o t 4 o n e q u a rt e r in ch o n e f o o t

VA FORM 08-6231

1 2 3 4 5 6 87 9

E

D

C

B

A

97 8654321

Revisions Date

Reviewed:

Reviewed:

Drawing Title Project Title

Location

Building Number Checked

Project No.

DRAWING NO.Drawn

Date

Approved: Project Director

Reviewed: Facility Director

Reviewed: Facility Manager

FULLY SPRINKLERED

PRINTS OF THIS DRAWING SHALL NOT BE USED FOR ANY PURPOSE WHATSOEVER

WITHOUT THE SEAL AND SIGNATURE OF THE PROFESSIONAL ENGINEER.

Miller-Remick LLC

1010 KINGS HIGHWAY SOUTH

CHERRY HILL, NEW JERSEY 08034

PHONE: (856)429-4000

FAX: (856)429-5002

M.E.P. & Structural Engineering A Service Disabled Veteran Owned Small Business

A Ser vi ce D is ab led Vet eran Owned Sma ll Business

SDVOSB

CVE

MR PROJECT NO: 0499-0139

2021-08-06

ISSUED FOR BID

AutoCAD SHX Text

RATED PARTITION UL W-L-2038

AutoCAD SHX Text

GWB PER PARTITION TYPE

AutoCAD SHX Text

ONE-PART FIRE- STOPPING SEALANT

AutoCAD SHX Text

WIRE MESH

AutoCAD SHX Text

ELEC CONDUIT MAX 1-1/4" DIA

AutoCAD SHX Text

AutoCAD SHX Text

CONDUIT PENETRATION DETAIL

AutoCAD SHX Text

NON-RATED PARTITION

AutoCAD SHX Text

ACOUSTICAL SEALANT ALL AROUND EA SIDE

AutoCAD SHX Text

MTL STUD TRACK WHERE PIPE EXCEEDS 3" DIA

AutoCAD SHX Text

CONDUIT SPRINKLER PIPE OR INSUL PIPE - SEE MEP DWGS

AutoCAD SHX Text

AutoCAD SHX Text

PENETRATION DETAIL

AutoCAD SHX Text

LOWEST PRIORITY

AutoCAD SHX Text

TAPE AND JOINT COMPOUND, TYP

AutoCAD SHX Text

HIGHEST PRIORITY

AutoCAD SHX Text

HM DOOR FRAME

AutoCAD SHX Text

TAPE AND JOINT COMPOUND, TYP

AutoCAD SHX Text

LOWEST PRIORITY

AutoCAD SHX Text

HIGHEST PRIORITY

AutoCAD SHX Text

WALL PRIORITY LEGEND

AutoCAD SHX Text TWO HOUR FIRE & SMOKE WALL TWO HOUR FIRE RATED WALL TWO HOUR SHAFTWALL ONE HOUR FIRE & SMOKE WALL ONE HOUR FIRE RATED WALL NON-RATED WALL

AutoCAD SHX Text

PRIORITY 1 - HIGHEST PRIORITY 2 PRIORITY 3 PRIORITY 4 PRIORITY 5 - LOWEST

AutoCAD SHX Text

AutoCAD SHX Text

WALL PRIORITY DETAILS

AutoCAD SHX Text NOTE: PROVIDE BLOCKING AS SHOWN FOR GRAB BARS, HANDRAILS, CABINETS, SHELF STANDARDS, TACK BOARDS AND OTHER WALL MOUNTED EQUIPMENT AND FOR SECURING PLUMBING PIPING AND OTHER ITEMS CONCEALED IN WALL.

AutoCAD SHX Text

MTL STUDS

AutoCAD SHX Text

KERF BLOCKING TO CLEAR BACK-BEND ON STUD FLANGE

AutoCAD SHX Text

SCREW THRU STUD TO ANCHOR BLOCKING

AutoCAD SHX Text 2x8 FR WOOD BLOCKING

AutoCAD SHX Text

AutoCAD SHX Text

BLOCK DETAIL (TYP.)

AutoCAD SHX Text

NTS

AutoCAD SHX Text

PARTITION TYPES

AutoCAD SHX Text

GA

AutoCAD SHX Text

STRUCTURAL DECK

AutoCAD SHX Text

CEILING PER FINISH SCHEDULE

AutoCAD SHX Text

20 GA MTL STUDS @ 16" OC

AutoCAD SHX Text

5/8" TYPE "X" GWB, BOTH SIDES (CBB AT TILE FINISH)

AutoCAD SHX Text

BASE AND FLOOR FINISH PER FINISH SCHEDULE

AutoCAD SHX Text

BACKER ROD AND SEALANT, BOTH SIDES

AutoCAD SHX Text

SET RUNNERS ON SEALANT, TYP

AutoCAD SHX Text

BACKER ROD AND SEALANT, BOTH SIDES

AutoCAD SHX Text

GA3

AutoCAD SHX Text

3-5/8" MTL STUDS

AutoCAD SHX Text

ACOUSTICAL INSULATION

AutoCAD SHX Text

CEILING PER FINISH SCHEDULE

AutoCAD SHX Text

GC

AutoCAD SHX Text

STRUCTURAL DECK

AutoCAD SHX Text

20 GA MTL STUDS @ 16" OC

AutoCAD SHX Text

5/8" TYPE "X" GWB, BOTH SIDES (CBB AT TILE FINISH)

AutoCAD SHX Text

BASE AND FLOOR FINISH PER FINISH SCHEDULE

AutoCAD SHX Text

BACKER ROD AND ACOUS SEALANT, BOTH SIDES

AutoCAD SHX Text

SET RUNNERS ON SEALANT, TYP

AutoCAD SHX Text

BACKER ROD AND ACOUSTICAL SEALANT, BOTH SIDES

AutoCAD SHX Text

GC3

AutoCAD SHX Text

3-5/8" MTL STUDS

AutoCAD SHX Text

SOUND RATED PARTITION STC 45

AutoCAD SHX Text

GD

AutoCAD SHX Text

STRUCTURAL DECK

AutoCAD SHX Text

20 GA MTL STUDS @ 24" OC

AutoCAD SHX Text

BASE AND FLOOR FINISH PER FINISH SCHEDULE

AutoCAD SHX Text

BACKER ROD AND ACOUS SEALANT, BOTH SIDES

AutoCAD SHX Text

SET RUNNERS ON SEALANT, TYP

AutoCAD SHX Text

CEILING PER FINISH SCHEDULE

AutoCAD SHX Text

SOUND RATED SMOKE PARTITION STC 54

AutoCAD SHX Text

BACKER ROD AND ACOUSTICAL SEALANT, BOTH SIDES

AutoCAD SHX Text

GD3

AutoCAD SHX Text

EXAM ROOMS

AutoCAD SHX Text

(1) LAYER 5/8" TYPE "C" CORE GWB

AutoCAD SHX Text

GG

AutoCAD SHX Text

STRUCTURAL DECK

AutoCAD SHX Text

20 GA MTL STUDS @ 16" OC

AutoCAD SHX Text

5/8" TYPE "X" GWB, BOTH SIDES (CBB AT TILE FINISH)

AutoCAD SHX Text

BASE AND FLOOR FINISH PER FINISH SCHEDULE

AutoCAD SHX Text

BACKER ROD AND SEALANT, BOTH SIDES

AutoCAD SHX Text

SET RUNNERS ON SEALANT, TYP

AutoCAD SHX Text

CEILING PER FINISH SCHEDULE

AutoCAD SHX Text

SMOKE PARTITION

AutoCAD SHX Text

BACKER ROD AND SEALANT, BOTH SIDES

AutoCAD SHX Text

GG3

AutoCAD SHX Text

3-5/8" MTL STUDS

AutoCAD SHX Text

(1) LAYER " TYPE "C" 58" TYPE "C" CORE GWB ON " (RC-1) 12" (RC-1) RESILIENT CHANNEL SPACED 24" O.C. ON METAL STUD

AutoCAD SHX Text

3" THERMAFIBER SAFB MINERAL WOOL INSULATION BATT

AutoCAD SHX Text

CEILING PER FINISH SCHEDULE

AutoCAD SHX Text

STRUCTURAL DECK

AutoCAD SHX Text

20 GA MTL STUDS @ 16" OC

AutoCAD SHX Text

5/8" TYPE "X" GWB, BOTH SIDES (CBB AT TILE FINISH)

AutoCAD SHX Text

BASE AND FLOOR FINISH PER FINISH SCHEDULE

AutoCAD SHX Text

BACKER ROD AND ACOUS SEALANT, BOTH SIDES

AutoCAD SHX Text

SET RUNNERS ON SEALANT, TYP

AutoCAD SHX Text

BACKER ROD AND ACOUSTICAL SEALANT, BOTH SIDES

AutoCAD SHX Text

GN15

AutoCAD SHX Text

3-5/8" MTL STUDS

AutoCAD SHX Text

ACOUSTICAL INSULATION

AutoCAD SHX Text

TOILET ROOM

AutoCAD SHX Text

GN

AutoCAD SHX Text

GD4

AutoCAD SHX Text

AT SMOKE PARTITIONS SOUND RATED

AutoCAD SHX Text

GC6

AutoCAD SHX Text

6" MTL STUDS

AutoCAD SHX Text

SOUND RATED PARTITION

AutoCAD SHX Text

NON-RATED PARTITION

AutoCAD SHX Text

GK

AutoCAD SHX Text

STRUCTURAL DECK

AutoCAD SHX Text

20 GA MTL STUDS @ 16" OC

AutoCAD SHX Text

5/8" TYPE "X" GWB (CBB AT TILE FINISH)

AutoCAD SHX Text

BASE AND FLOOR FINISH PER FINISH SCHEDULE

AutoCAD SHX Text

BACKER ROD AND SEALANT, BOTH SIDES

AutoCAD SHX Text

SET RUNNERS ON SEALANT, TYP

AutoCAD SHX Text

CEILING PER FINISH SCHEDULE

AutoCAD SHX Text

GK1

AutoCAD SHX Text

1-1/2" MTL STUDS

AutoCAD SHX Text

BACKER ROD AND SEALANT

AutoCAD SHX Text

EXISTING OR ADJACENT WALL, WHERE APPLICABLE

AutoCAD SHX Text

GK2

AutoCAD SHX Text

2-1/2" MTL STUDS

AutoCAD SHX Text

GK3

AutoCAD SHX Text

3-5/8" MTL STUDS

AutoCAD SHX Text

FURRING

AutoCAD SHX Text

GE

AutoCAD SHX Text

STRUCTURAL DECK

AutoCAD SHX Text

34" EXISTING FINISH PLASTER VENEER SHALL BE PATCHED, REPAIRED AND REFINISHED

AutoCAD SHX Text

BASE AND FLOOR FINISH PER FINISH SCHEDULE

AutoCAD SHX Text

RESURFACING SELF LEVELING COMPOUND

AutoCAD SHX Text

CEILING PER FINISH SCHEDULE

AutoCAD SHX Text

GE

AutoCAD SHX Text

EXISTING

AutoCAD SHX Text

34" PLASTER VENEER APPLIED TO EXISTING SUBSTRATE

AutoCAD SHX Text

EXISTING MASONRY WALL, WHERE APPLICABLE

AutoCAD SHX Text

EXISTING PLASTER FINISH

AutoCAD SHX Text

PLASTER VENEER

AutoCAD SHX Text

FINISHING TRIM AT 6" ABOVE CEILING - PER FINISH SCHEDULE

AutoCAD SHX Text

GK0

AutoCAD SHX Text

7/8" MTL FURRING

AutoCAD SHX Text

PLASTER VENEER FINISH TO REMAIN ON EXTERIOR WALLS. TYP. @ GK1 PARTITION TYPE.

AutoCAD SHX Text

DOOR OPENING

AutoCAD SHX Text

DOUBLE DOOR OPENING

AutoCAD SHX Text

ABOVE CEILING OPENING

AutoCAD SHX Text

BELOW CEILING OPENING

AutoCAD SHX Text

LARGE BELOW CEILING OPENING

AutoCAD SHX Text

LARGE ABOVE CEILING OPENING

AutoCAD SHX Text

OPENING ABOVE CEILING WHICH INTERRUPTS LOWER OPENING JAMB STUDS

AutoCAD SHX Text

DOOR OPENING

AutoCAD SHX Text

DOUBLE STUDS (FULL HEIGHT)

AutoCAD SHX Text

DOUBLE STUDS (FULL HEIGHT)

AutoCAD SHX Text

DOUBLE STUDS (FULL HEIGHT)

AutoCAD SHX Text

DOUBLE STUDS (FULL HEIGHT)

AutoCAD SHX Text

22 GA BOTTOM TRACK (TYP)

AutoCAD SHX Text

CEILING LINE

AutoCAD SHX Text

22 GA METAL TOP TRACK W/ DEFLECTION TRACK (TYP)

AutoCAD SHX Text 2" x 22 GA METAL STRAP

AutoCAD SHX Text

DOUBLE STUDS (FULL HEIGHT)

AutoCAD SHX Text

DOOR OPENING

AutoCAD SHX Text

DOUBLE DOOR OPENING

AutoCAD SHX Text

BELOW CEILING OPENING

AutoCAD SHX Text

LARGE BELOW CEILING OPENING

AutoCAD SHX Text

DOUBLE STUDS

AutoCAD SHX Text

DOUBLE STUDS

AutoCAD SHX Text

DOUBLE STUDS

AutoCAD SHX Text

PROVIDE DIAGONAL BRACING OF TOP TRACK AT 48" O.C. MAX BETWEEN FULL HEIGHT STUDS

AutoCAD SHX Text GENERAL NOTES: : A. ALL STUDS ARE SPACED 16" O.C. MAXIMUM. ALL STUDS ARE SPACED 16" O.C. MAXIMUM. B. ALL STUDS SHALL BE `C' STUDS WITH " ALL STUDS SHALL BE `C' STUDS WITH " 14" FLANGE MINIMUM. C. IN NO CASE SHALL DOUBLE STUDS AT SIDES IN NO CASE SHALL DOUBLE STUDS AT SIDES OF OPENING BE CUT FOR DUCTWORK OR OTHER MECHANICAL SYSTEM. D. AT LEAD LINED PARTITIONS STUDS SHOULD BE AT LEAD LINED PARTITIONS STUDS SHOULD BE 20 GA.

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

REVISION

AutoCAD SHX Text 10/13/21

VHASYRBauerD3 Typewritten Text

SEE NOTE #1

VHASYRBauerD3 Callout NOTE #1 - EXISTING WALL ON GRID LINE [1] DOES NOT HAVE EXISTING 3/4-INCH PLASTER. PROVIDE METAL LATH PLUS PLASTER ON INSIDE FACE OF EXISTING C.M.U.

VHASYRBauerD3 Callout

NOTE: [GD] IS THE TYPICAL PARTITION WHERE PARTITION TYPE IS NOT NOTED ON PLANS

VHASYRBauerD3 Callout NOTE: SHIM FURRING WHERE THERE IS NO EXISTING PLASTER OR WHERE EXISTING PLASTER IS DAMAGED.

Sheets and Views
A-501 PARTITION TYPES AND DETAILS-A-501 PARTITION TYPES AND DETAILS
UL DETAIL WL
UL DETAIL CA
RATED PARTITION
NONRATED PARTITION
PARTTITION
DETAIL 9
WALL PARTITION
FRAMING ELEV-1
FRAMING ELEV-2

File details come from the government source that posted it. Updated .