230534 111324 Asbestos Spot Survey PDF.pdf

PDF 3 MB Posted

Attached to
402-23-794 Modernize Campus Corridors
Solicitation number
36C24126R0120
Issued by

About this file

This is an asbestos testing report for the Togus VA Medical Center in Augusta, Maine, documenting bulk material sampling and analysis conducted by RPF Environmental in October 2024.

The survey identified asbestos-containing material (ACM) in 12 floor tile and mastic samples across the VA Medical Center corridor, with asbestos content ranging from 2% to 7% chrysotile detected via polarized light microscopy analysis. All ACM samples were floor tiles with mastic located in various buildings (Buildings 200, 206, 209, 232) and specific rooms, with locations precisely documented in the report's appendices and blueprints. Additional testing of gypsum board, plaster, ceiling tiles, and cove base glue samples showed no asbestos detected. The report recommends that damaged ACM be repaired at minimum, with abatement specifications prepared and repair versus removal options obtained from qualified licensed contractors. An Operations and Maintenance Program is recommended for safe management of ACM per current OSHA and EPA requirements. The survey was limited to the VS Medical Center corridor with 21 homogeneous groups sampled across 73 total samples analyzed. The report notes that a full inspection of the entire corridor was not performed, and additional pre-construction surveys may be required prior to renovation activity to comply with State of Maine, EPA, and OSHA requirements. All analytical work was performed by Scientific Analytical Institute, Inc. using EPA Methods 600/R-93/116 and gravimetric reduction techniques.

View the file

Other files

File Type Posted
36C24126R0120 0005.pdf PDF
36C24126R0120 0004.docx DOCX document
36C24126R0120 0003.docx DOCX document
21 13 13 - WET-PIPE SPRINKLER SYSTEMS.pdf PDF
36C24126R0120 0002.docx DOCX document
Statement of Items.docx DOCX document
Sign in sheet - Site Visit.pdf PDF
36C24126R0120 0001.docx DOCX document
402-23-794 - Final Specifications.pdf PDF
402-23-794 - ICRA.pdf PDF
ME20260009 WR Determination.pdf PDF
36C24126R0120.docx DOCX document
SOW Attachment - Security Badge form.pdf PDF
Itemized Cost Breakdown.xlsx XLSX spreadsheet
Construction SOW.pdf PDF
SOW Attachment - Seasonal Influenza with Vaccines.pdf PDF
402-23-794 - PCRA.pdf PDF
SOW Attachment - Togus Campus Map.pdf PDF
402-23-794 - Final Bid Drawings.pdf PDF
Show all 19

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

November 14, 2024

Jake Lantz, PE Senior Project Manager Above Group Inc.

170 Commerce Ave Suite 200 Portsmouth, NH 03801

Re: Togus VA Medical Center - 1 VA Center, Augusta, ME Limited Asbestos Testing RPF File No. 230534

Dear Mr. Lantz, In accordance with our scope of work dated October 17, 2023, RPF Environmental (RPF) conducted bulk material sampling of suspect material in the Togus VA Medical Center in Augusta, ME. The survey was limited to the VS Medical Center corridor. The sampling was completed, as designated by you, for analysis to determine possible asbestos content. The sampling was conducted by Conner Jinx & Nick Howard on October 22, 2024, and October 29, 2024, in accordance with current State and federal rules and regulations. The analytical results and sample locations are enclosed with this report and the results were reviewed with you previously.

Asbestos is the name for a group of naturally occurring minerals that separate into strong, very fine fibers. The adverse health effects associated with asbestos exposure have been extensively studied for many years. Results of these studies and epidemiological investigations have demonstrated that inhalation of asbestos fibers may lead to increased risk of developing one or more diseases. In all cases, extreme care must be used not to disturb asbestos-containing materials or to create fiber release episodes.

Twenty-one (21) homogeneous groups of accessible suspect material were sampled during this testing. In accordance with current industry sampling protocols, a total of seventy-three (73) samples were collected and submitted for analysis using polarized light microscopy. Asbestos containing material (ACM) is defined by current EPA regulations as materials having equal to or greater than 1% asbestos content.

As listed in appendix A results as shown, equal to or greater than 1% asbestos was detected in the material samples listed below and these materials are defined as ACM:

• Floor tile & mastic, white/gold, in front of Room 118

• Floor tile & mastic, white/tan, between Rooms 132F & 107

• Floor tile & mastic, white/tan, Northeast of Room 107

• Floor tile & mastic, white/purple, in front of exit

• Floor tile & mastic, white/gold, SW, ramp, entrance to building 201

• Floor tile & mastic, white/green, entrance to Building 232

• Floor tile & mastic, white/gold, Building 206, entry, Northeast, behind door, hallway

Limited Asbestos Testing Project No. 230534 Above Group Inc. – VA Medical Center, Augusta, ME Page 2

• Floor tile & mastic, blue, front of Building 206, exit

• Floor tile & mastic, light gray/white, Building 200, in front of door 16B

• Floor tile & mastic, tan/dark green, Building 209, hallway, in front of emergency exit

• Floor tile & mastic, light gray/white/dark gray, Building 209, in front of Room 153, on hatch

• Floor tile & mastic, tan/white/dark brown, in front of entrance to 206, beside heater

Please note that a full inspection of the VA Medical Center corridor was not performed during this limited testing. In the event that other materials or areas of the building will be impacted by planned upgrades, maintenance activity, renovation or demolition activity, please notify our office to arrange for additional site inspections, testing and analysis.

It is recommended that the damaged ACM be repaired at a minimum. An abatement specification should be prepared for the work, and it is recommended that options for repair versus removal be addressed and bid alternates be obtained from a qualified, licensed asbestos abatement contractor.

Care should be used during the interim to ensure that damage or further damage to the material does not occur and that dust is not created in the immediate area.

In general, ACM should be managed in accordance with current OSHA and EPA requirements, including but not limited to proper hazard communications, labeling, and maintenance of the ACM.

It is recommended that an Operations and Maintenance Program be prepared and implemented to allow for the safe use and maintenance of buildings with ACM present.

Please also reference existing asbestos OSHA hazard communication documentation for this building for details of the accessible ACM and presumed ACM present. Prior to renovation activity, additional pre-construction surveys may / will be required to comply with current State of ME, EPA, and OSHA requirements throughout affected areas. If you would like further assistance or have questions, please call our office.

Sincerely, RPF ENVIRONMENTAL

Conner Jinx EH&S Consultant Licensed Inspector

Enclosures: Appendix A: Sampling Results Appendix B: Pictures Appendix C: Blueprints Appendix D: Limitations

230534 Above Group VAMC 102924

APPENDIX A

Bulk Asbestos Analysis by Polarized Light Microscopy

Gravimetric Reduction EPA Method: 600/R-93/116 and 600/M4-82-020

Lab Order ID:Attn: 10066533Customer: RPF Environmental Inc.

320 1st NH Turnpike Northwood, NH 03261

Analysis:

Date Received:

Sean Smith

PGR

10/25/2024

Project: 230534 Togus VA Medical Center, Augusta,ME

Date Reported: 10/29/2024

Sample ID

Lab Sample ID

Description

Lab Notes

Asbestos ( Wt. % )

Acid Soluble ( Wt. % )

Other Non-Asbestos

( Wt. % )

Organic ( Wt. % )

102224-HG1b

10066533_0002

Floor tile & mastic, white/gold, SW of room

101 - None Detected 93.78%6.22%

102224-HG1c

10066533_0003

Floor tile & mastic, white/gold, in front of room 103 - None Detected 84.40%15.60%

102224-HG3a

10066533_0007

Floor tile & mastic, white/purple, SW of room 132F - None Detected 93.05%6.95%

102224-HG3c

10066533_0009

Floor tile & mastic, white/purple, bottom of staircase 1 - None Detected 80.26%19.74%

102224-HG6a

10066533_0016

Floor tile & mastic, white/tan, building 204, in front of café entrance - None Detected 81.05%18.95%

102224-HG6b

10066533_0017

Floor tile & mastic, white/tan, building 204, NE of café, mid way dow - None Detected 56.91%43.09%

102224-HG6c

10066533_0018

Floor tile & mastic, white/tan, in front of

Patriot Café - None Detected 75.29%24.71%

102224-HG7a

10066533_0019

Floor tile & mastic, building 205, in front of mens bathroom - None Detected 77.70%22.30%

Disclaimer: This report relates only to the samples tested and may not be reproduced, except in full, without the written approval of SAI. This report may not be used by the client to claim product endorsement by NVLAP or any other agency of the U.S. government. Estimated MDL is 0.1%.

Heather Boykin (36)

Analyst Approved Signatory

Page 1 of 5P-F-004 r17 2/28/2027 Scientific Analytical Institute, Inc. 4604 Dundas Dr. Greensboro, NC 27407 (336) 292-3888

Gravimetric Reduction EPA Method: 600/R-93/116 and 600/M4-82-020

Lab Order ID:Attn: 10066533Customer: RPF Environmental Inc.

320 1st NH Turnpike Northwood, NH 03261

Analysis:

Date Received:

Sean Smith

PGR

10/25/2024

Project: 230534 Togus VA Medical Center, Augusta,ME

Date Reported: 10/29/2024

Sample ID

Lab Sample ID

Description

Lab Notes

Asbestos ( Wt. % )

Acid Soluble ( Wt. % )

Other Non-Asbestos

( Wt. % )

Organic ( Wt. % )

102224-HG7b

10066533_0020

Floor tile & mastic, building 205, in front of womens bathroom - None Detected 61.22%38.78%

102224-HG7c

10066533_0021

Floor tile & mastic, dark gold, between Patriot vending and Patriot stor - None Detected 74.24%25.76%

102224-HG8a

10066533_0022

Floor tile & mastic, sandy, building 248, in front of room 110 - None Detected 82.64%17.36%

102224-HG8b

10066533_0023

Floor tile & mastic, sandy, building 248, in front of room 112 - None Detected 56.91%43.09%

102224-HG8c

10066533_0024

Floor tile & mastic, sandy, building 248, in front of room 116 - None Detected 82.86%17.14%

102224-HG9a

10066533_0025

Floor tile & mastic, blue/white, in front of building 248, SE of chap - None Detected 80.19%19.81%

102224-HG9b

10066533_0026

Floor tile & mastic, blue/white, front of door to lot 7 and 9 - None Detected 79.99%20.01%

102224-HG9c

10066533_0027

Floor tile & mastic, blue/white, building 235, in front of chapel - None Detected 51.77%48.23%

Disclaimer: This report relates only to the samples tested and may not be reproduced, except in full, without the written approval of SAI. This report may not be used by the client to claim product endorsement by NVLAP or any other agency of the U.S. government. Estimated MDL is 0.1%.

Heather Boykin (36)

Page 2 of 5P-F-004 r17 2/28/2027 Scientific Analytical Institute, Inc. 4604 Dundas Dr. Greensboro, NC 27407 (336) 292-3888

Gravimetric Reduction EPA Method: 600/R-93/116 and 600/M4-82-020

Lab Order ID:Attn: 10066533Customer: RPF Environmental Inc.

320 1st NH Turnpike Northwood, NH 03261

Analysis:

Date Received:

Sean Smith

PGR

10/25/2024

Project: 230534 Togus VA Medical Center, Augusta,ME

Date Reported: 10/29/2024

Sample ID

Lab Sample ID

Description

Lab Notes

Asbestos ( Wt. % )

Acid Soluble ( Wt. % )

Other Non-Asbestos

( Wt. % )

Organic ( Wt. % )

102224-HG10a

10066533_0028

Floor tile & mastic, white/blue grain, West of chapel, expansion joint - None Detected 79.43%20.57%

102224-HG10b

10066533_0029

Floor tile & mastic, white/blue, between buildings 235 & 210, W - None Detected 80.99%19.01%

102224-HG10c

10066533_0030

Floor tile & mastic, white/blue grain, building 210, in front of - None Detected 53.34%46.66%

102224-HG11a

10066533_0031

Floor tile & mastic, mint green/white/black, building 210, N entrance - None Detected 78.94%21.06%

102224-HG11b

10066533_0032

Floor tile & mastic, mint green/white/black, N corner of main entry to - None Detected 78.67%21.33%

102224-HG11c

10066533_0033

Floor tile & mastic, mint green/white/black, in front of W stairwell - None Detected 56.44%43.56%

102224-HG12a

10066533_0034

Floor tile & mastic, light/dark tan, building

255, in front of building, - None Detected 76.02%23.98%

102224-HG12b

10066533_0035

Floor tile & mastic, white/purple, NW in hallway, between buildin - None Detected 81.53%18.47%

Disclaimer: This report relates only to the samples tested and may not be reproduced, except in full, without the written approval of SAI. This report may not be used by the client to claim product endorsement by NVLAP or any other agency of the U.S. government. Estimated MDL is 0.1%.

Heather Boykin (36)

Page 3 of 5P-F-004 r17 2/28/2027 Scientific Analytical Institute, Inc. 4604 Dundas Dr. Greensboro, NC 27407 (336) 292-3888

Gravimetric Reduction EPA Method: 600/R-93/116 and 600/M4-82-020

Lab Order ID:Attn: 10066533Customer: RPF Environmental Inc.

320 1st NH Turnpike Northwood, NH 03261

Analysis:

Date Received:

Sean Smith

PGR

10/25/2024

Project: 230534 Togus VA Medical Center, Augusta,ME

Date Reported: 10/29/2024

Sample ID

Lab Sample ID

Description

Lab Notes

Asbestos ( Wt. % )

Acid Soluble ( Wt. % )

Other Non-Asbestos

( Wt. % )

Organic ( Wt. % )

102224-HG12c

10066533_0036

Floor tile & mastic, dark/light yellow, front of building 200, S corner - None Detected 73.11%26.89%

102224-HG13a

10066533_0037

Floor tile & mastic, light yellow/white/brown, front of room 25, NE of e - None Detected 77.53%22.47%

102224-HG13b

10066533_0038

Floor tile & mastic, light yellow/white/brown, building 200, NE of roo - None Detected 76.50%23.50%

102224-HG13c

10066533_0039

Floor tile & mastic, light yellow/white/brown, building 200, SW, in fro - None Detected 45.27%54.73%

102224-HG14a

10066533_0040

Floor tile & mastic, light gray/white, building 200, SW, beside door 7 - None Detected 80.18%19.82%

102224-HG14b

10066533_0041

Floor tile & mastic, light gray/white, building 200, in front of door 18 - None Detected 80.20%19.80%

102224-HG15a

10066533_0043

Floor tile & mastic, tan/dark green, front entrance from building 2 - None Detected 70.72%29.28%

102224-HG15b

10066533_0044

Floor tile & mastic, tan/dark green, between buildings 200 & 209, mid - None Detected 74.34%25.66%

Disclaimer: This report relates only to the samples tested and may not be reproduced, except in full, without the written approval of SAI. This report may not be used by the client to claim product endorsement by NVLAP or any other agency of the U.S. government. Estimated MDL is 0.1%.

Heather Boykin (36)

Page 4 of 5P-F-004 r17 2/28/2027 Scientific Analytical Institute, Inc. 4604 Dundas Dr. Greensboro, NC 27407 (336) 292-3888

Gravimetric Reduction EPA Method: 600/R-93/116 and 600/M4-82-020

Lab Order ID:Attn: 10066533Customer: RPF Environmental Inc.

320 1st NH Turnpike Northwood, NH 03261

Analysis:

Date Received:

Sean Smith

PGR

10/25/2024

Project: 230534 Togus VA Medical Center, Augusta,ME

Date Reported: 10/29/2024

Sample ID

Lab Sample ID

Description

Lab Notes

Asbestos ( Wt. % )

Acid Soluble ( Wt. % )

Other Non-Asbestos

( Wt. % )

Organic ( Wt. % )

102224-HG16a

10066533_0046

Floor tile & mastic, light gray/white/dark gray, building 209 entrance, S - None Detected 76.13%23.87%

102224-HG16c

10066533_0048

Floor tile & mastic, light gray/white/dark gray, building 209 entrance, S - None Detected 77.66%22.34%

102224-HG17a

10066533_0049

Floor tile & mastic, tan/white/dark brown, between rooms? 206 & 2 - None Detected 74.37%25.63%

102224-HG17c

10066533_0051

Floor tile & mastic, tan/white/dark brown, between rooms? 206 & 2 - None Detected 74.36%25.64%

Disclaimer: This report relates only to the samples tested and may not be reproduced, except in full, without the written approval of SAI. This report may not be used by the client to claim product endorsement by NVLAP or any other agency of the U.S. government. Estimated MDL is 0.1%.

Heather Boykin (36)

Page 5 of 5P-F-004 r17 2/28/2027 Scientific Analytical Institute, Inc. 4604 Dundas Dr. Greensboro, NC 27407 (336) 292-3888

By Polarized Light Microscopy EPA Method: 600/R-93/116 and

40 CFR, Part 763, Subpart E, App.E

Lab Order ID:Attn: 10066533Customer: RPF Environmental Inc.

320 1st NH Turnpike Northwood, NH 03261

Analysis:

Date Received:

Sean Smith

PLM

10/25/2024

Project: 230534 Togus VA Medical Center, Augusta,ME

Date Reported: 10/29/2024

Sample ID

Lab Sample ID

Description

Lab Notes Asbestos

Fibrous Components

Non-Fibrous Components Treatment

Attributes

102224-HG1a

10066533_0001

Floor tile & mastic, white/gold, in front of room

118 3% Chrysotile 97% Other

Non-Fibrous

Dissolved, Crushed

Black, Gray

Heterogeneous mixed mastic/leveling compound

102224-HG1b

10066533_0002

Floor tile & mastic, white/gold, SW of room 101

Not Analyzed gravimetric reduction

102224-HG1c

10066533_0003

Floor tile & mastic, white/gold, in front of room

103 Not Analyzed gravimetric reduction

102224-HG2a

10066533_0004

Floor tile & mastic, white/tan, between rooms 132F & 107

6% Chrysotile 94% Other

Non-Fibrous

Dissolved

Black

Homogeneous

102224-HG2b

10066533_0005

Floor tile & mastic, white/tan, NE of room 107

2% Chrysotile 98% Other

Non-Fibrous

Dissolved

Tan, Gray

Homogeneous

102224-HG2c

10066533_0006

Floor tile & mastic, white/tan, mid east of room 102

Not Analyzed

102224-HG3a

10066533_0007

Floor tile & mastic, white/purple, SW of room

132F Not Analyzed gravimetric reduction

102224-HG3b

10066533_0008

Floor tile & mastic, white/purple, in front of exit

3% Chrysotile 97% Other

Non-Fibrous

Dissolved

Black

Homogeneous

Disclaimer: Due to the nature of the EPA 600 method, asbestos may not be detected in samples containing low levels of asbestos. We strongly recommend that analysis of floor tiles, vermiculite, and/or heterogenous soil samples be conducted by TEM for confirmation of "None Detected" by PLM. This report relates only to the samples tested and may not be reproduced, except in full, without the written approval of SAI. This report may not be used by the client to claim product endorsement by NVLAP or any other agency of the U.S. government. Analytical uncertainty available upon request. Scientific Analytical Institute participates in the NVLAP Proficiency Testing program.

Unless otherwise noted blank sample correction was not performed. Estimated MDL is 0.1%.

Heather Boykin (51)

Page 1 of 7P-F-002 r15 1/15/2028 Scientific Analytical Institute, Inc. 4604 Dundas Dr. Greensboro, NC 27407 (336) 292-3888

EPA Method: 600/R-93/116 and

40 CFR, Part 763, Subpart E, App.E

Lab Order ID:Attn: 10066533Customer: RPF Environmental Inc.

320 1st NH Turnpike Northwood, NH 03261

Analysis:

Date Received:

Sean Smith

PLM

10/25/2024

Project: 230534 Togus VA Medical Center, Augusta,ME

Date Reported: 10/29/2024

Sample ID

Lab Sample ID

Description

Lab Notes Asbestos

Fibrous Components

Non-Fibrous Components Treatment

Attributes

102224-HG3c

10066533_0009

Floor tile & mastic, white/purple, bottom of staircase 1 Not Analyzed gravimetric reduction

102224-HG4a

10066533_0010

Floor tile & mastic, white/gold, SW, ramp, entrance to building 201 2% Chrysotile 98% Other

Non-Fibrous

Dissolved

Off-white, Tan

Homogeneous

102224-HG4b

10066533_0011

Floor tile & mastic, white/green, entrance to building 232 4% Chrysotile 96% Other

Non-Fibrous

Dissolved

Black

Homogeneous small sample

102224-HG4c

10066533_0012

Floor tile & mastic, white/purple, building 206 entry, SW, hallway Not Analyzed

102224-HG5a

10066533_0013

Floor tile & mastic, white/gold, building 206 entry, NE, behind door, hallway 2% Chrysotile 98% Other

Non-Fibrous

Dissolved

Tan, Gray

Homogeneous

102224-HG5b

10066533_0014

Floor tile & mastic, blue, front of building 206, exit

7% Chrysotile 93% Other

Non-Fibrous

Dissolved

Black

Homogeneous

102224-HG5c

10066533_0015

Floor tile & mastic, white/gold, entry to building

204, NE Not Analyzed

102224-HG6a

10066533_0016

Floor tile & mastic, white/tan, building 204, in front of café entrance Not Analyzed gravimetric reduction

Disclaimer: Due to the nature of the EPA 600 method, asbestos may not be detected in samples containing low levels of asbestos. We strongly recommend that analysis of floor tiles, vermiculite, and/or heterogenous soil samples be conducted by TEM for confirmation of "None Detected" by PLM. This report relates only to the samples tested and may not be reproduced, except in full, without the written approval of SAI. This report may not be used by the client to claim product endorsement by NVLAP or any other agency of the U.S. government. Analytical uncertainty available upon request. Scientific Analytical Institute participates in the NVLAP Proficiency Testing program.

Unless otherwise noted blank sample correction was not performed. Estimated MDL is 0.1%.

Heather Boykin (51)

Page 2 of 7P-F-002 r15 1/15/2028 Scientific Analytical Institute, Inc. 4604 Dundas Dr. Greensboro, NC 27407 (336) 292-3888

EPA Method: 600/R-93/116 and

40 CFR, Part 763, Subpart E, App.E

Lab Order ID:Attn: 10066533Customer: RPF Environmental Inc.

320 1st NH Turnpike Northwood, NH 03261

Analysis:

Date Received:

Sean Smith

PLM

10/25/2024

Project: 230534 Togus VA Medical Center, Augusta,ME

Date Reported: 10/29/2024

Sample ID

Lab Sample ID

Description

Lab Notes Asbestos

Fibrous Components

Non-Fibrous Components Treatment

Attributes

102224-HG6b

10066533_0017

Floor tile & mastic, white/tan, building 204, NE of café, mid way down hallway Not Analyzed gravimetric reduction

102224-HG6c

10066533_0018

Floor tile & mastic, white/tan, in front of Patriot Café

Not Analyzed gravimetric reduction

102224-HG7a

10066533_0019

Floor tile & mastic, building 205, in front of mens bathroom Not Analyzed gravimetric reduction

102224-HG7b

10066533_0020

Floor tile & mastic, building 205, in front of womens bathroom Not Analyzed gravimetric reduction

102224-HG7c

10066533_0021

Floor tile & mastic, dark gold, between Patriot vending and Patriot store Not Analyzed gravimetric reduction

102224-HG8a

10066533_0022

Floor tile & mastic, sandy, building 248, in front of room

110 Not Analyzed gravimetric reduction

102224-HG8b

10066533_0023

Floor tile & mastic, sandy, building 248, in front of room

112 Not Analyzed gravimetric reduction

102224-HG8c

10066533_0024

Floor tile & mastic, sandy, building 248, in front of room

116 Not Analyzed gravimetric reduction

Disclaimer: Due to the nature of the EPA 600 method, asbestos may not be detected in samples containing low levels of asbestos. We strongly recommend that analysis of floor tiles, vermiculite, and/or heterogenous soil samples be conducted by TEM for confirmation of "None Detected" by PLM. This report relates only to the samples tested and may not be reproduced, except in full, without the written approval of SAI. This report may not be used by the client to claim product endorsement by NVLAP or any other agency of the U.S. government. Analytical uncertainty available upon request. Scientific Analytical Institute participates in the NVLAP Proficiency Testing program.

Unless otherwise noted blank sample correction was not performed. Estimated MDL is 0.1%.

Heather Boykin (51)

Page 3 of 7P-F-002 r15 1/15/2028 Scientific Analytical Institute, Inc. 4604 Dundas Dr. Greensboro, NC 27407 (336) 292-3888

EPA Method: 600/R-93/116 and

40 CFR, Part 763, Subpart E, App.E

Lab Order ID:Attn: 10066533Customer: RPF Environmental Inc.

320 1st NH Turnpike Northwood, NH 03261

Analysis:

Date Received:

Sean Smith

PLM

10/25/2024

Project: 230534 Togus VA Medical Center, Augusta,ME

Date Reported: 10/29/2024

Sample ID

Lab Sample ID

Description

Lab Notes Asbestos

Fibrous Components

Non-Fibrous Components Treatment

Attributes

102224-HG9a

10066533_0025

Floor tile & mastic, blue/white, in front of building 248, SE of chapel Not Analyzed gravimetric reduction

102224-HG9b

10066533_0026

Floor tile & mastic, blue/white, front of door to lot 7 and 9 Not Analyzed gravimetric reduction

102224-HG9c

10066533_0027

Floor tile & mastic, blue/white, building 235, in front of chapel Not Analyzed gravimetric reduction

102224-HG10a

10066533_0028

Floor tile & mastic, white/blue grain, West of chapel, expansion joint Not Analyzed gravimetric reduction

102224-HG10b

10066533_0029

Floor tile & mastic, white/blue, between buildings 235 & 210, W of Eucharistic room Not Analyzed gravimetric reduction

102224-HG10c

10066533_0030

Floor tile & mastic, white/blue grain, building 210, in front of main door, South Not Analyzed mastic/leveling compound -gravimetric reduction

102224-HG11a

10066533_0031

Floor tile & mastic, mint green/white/black, building

210, N entrance from hallway Not Analyzed gravimetric reduction

102224-HG11b

10066533_0032

Floor tile & mastic, mint green/white/black, N corner of main entry to building 210 Not Analyzed gravimetric reduction

Disclaimer: Due to the nature of the EPA 600 method, asbestos may not be detected in samples containing low levels of asbestos. We strongly recommend that analysis of floor tiles, vermiculite, and/or heterogenous soil samples be conducted by TEM for confirmation of "None Detected" by PLM. This report relates only to the samples tested and may not be reproduced, except in full, without the written approval of SAI. This report may not be used by the client to claim product endorsement by NVLAP or any other agency of the U.S. government. Analytical uncertainty available upon request. Scientific Analytical Institute participates in the NVLAP Proficiency Testing program.

Unless otherwise noted blank sample correction was not performed. Estimated MDL is 0.1%.

Heather Boykin (51)

Page 4 of 7P-F-002 r15 1/15/2028 Scientific Analytical Institute, Inc. 4604 Dundas Dr. Greensboro, NC 27407 (336) 292-3888

EPA Method: 600/R-93/116 and

40 CFR, Part 763, Subpart E, App.E

Lab Order ID:Attn: 10066533Customer: RPF Environmental Inc.

320 1st NH Turnpike Northwood, NH 03261

Analysis:

Date Received:

Sean Smith

PLM

10/25/2024

Project: 230534 Togus VA Medical Center, Augusta,ME

Date Reported: 10/29/2024

Sample ID

Lab Sample ID

Description

Lab Notes Asbestos

Fibrous Components

Non-Fibrous Components Treatment

Attributes

102224-HG11c

10066533_0033

Floor tile & mastic, mint green/white/black, in front of

W stairwell Not Analyzed gravimetric reduction

102224-HG12a

10066533_0034

Floor tile & mastic, light/dark tan, building 255, in front of building, in hallway Not Analyzed gravimetric reduction

102224-HG12b

10066533_0035

Floor tile & mastic, white/purple, NW in hallway, between buildings 255 & 200, at expansion joint Not Analyzed gravimetric reduction

102224-HG12c

10066533_0036

Floor tile & mastic, dark/light yellow, front of building 200, S corner of hallway Not Analyzed gravimetric reduction

102224-HG13a

10066533_0037

Floor tile & mastic, light yellow/white/brown, front of room 25, NE of entrance to building 200 Not Analyzed gravimetric reduction

102224-HG13b

10066533_0038

Floor tile & mastic, light yellow/white/brown, building 200, NE of room 19, beside lobby Not Analyzed gravimetric reduction

102224-HG13c

10066533_0039

Floor tile & mastic, light yellow/white/brown, building 200, SW, in front of room 3 Not Analyzed gravimetric reduction

102224-HG14a

10066533_0040

Floor tile & mastic, light gray/white, building 200, SW, beside door 7 Not Analyzed gravimetric reduction

Disclaimer: Due to the nature of the EPA 600 method, asbestos may not be detected in samples containing low levels of asbestos. We strongly recommend that analysis of floor tiles, vermiculite, and/or heterogenous soil samples be conducted by TEM for confirmation of "None Detected" by PLM. This report relates only to the samples tested and may not be reproduced, except in full, without the written approval of SAI. This report may not be used by the client to claim product endorsement by NVLAP or any other agency of the U.S. government. Analytical uncertainty available upon request. Scientific Analytical Institute participates in the NVLAP Proficiency Testing program.

Unless otherwise noted blank sample correction was not performed. Estimated MDL is 0.1%.

Heather Boykin (51)

Page 5 of 7P-F-002 r15 1/15/2028 Scientific Analytical Institute, Inc. 4604 Dundas Dr. Greensboro, NC 27407 (336) 292-3888

EPA Method: 600/R-93/116 and

40 CFR, Part 763, Subpart E, App.E

Lab Order ID:Attn: 10066533Customer: RPF Environmental Inc.

320 1st NH Turnpike Northwood, NH 03261

Analysis:

Date Received:

Sean Smith

PLM

10/25/2024

Project: 230534 Togus VA Medical Center, Augusta,ME

Date Reported: 10/29/2024

Sample ID

Lab Sample ID

Description

Lab Notes Asbestos

Fibrous Components

Non-Fibrous Components Treatment

Attributes

102224-HG14b

10066533_0041

Floor tile & mastic, light gray/white, building 200, in front of door 18 Not Analyzed gravimetric reduction

102224-HG14c

10066533_0042

Floor tile & mastic, light gray/white, building 200, in front of door 16B 4% Chrysotile 96% Other

Non-Fibrous

Crushed, Dissolved

Black, Yellow

Heterogeneous very small sample -mastic/leveling compound

102224-HG15a

10066533_0043

Floor tile & mastic, tan/dark green, front entrance from building 200 to building 209 Not Analyzed gravimetric reduction

102224-HG15b

10066533_0044

Floor tile & mastic, tan/dark green, between buildings 200

& 209, middle of hallway Not Analyzed gravimetric reduction

102224-HG15c

10066533_0045

Floor tile & mastic, tan/dark green, building 209, hallway, in front of emergency exit 3% Chrysotile 97% Other

Non-Fibrous

Dissolved

Black

Homogeneous

102224-HG16a

10066533_0046

Floor tile & mastic, light gray/white/dark gray, building 209 entrance, SE, under stairs Not Analyzed gravimetric reduction

102224-HG16b

10066533_0047

Floor tile & mastic, light gray/white/dark gray, building 209, in front of room 153, on hatch 3% Chrysotile 97% Other

Non-Fibrous

Dissolved

Black

Homogeneous

102224-HG16c

10066533_0048

Floor tile & mastic, light gray/white/dark gray, building 209 entrance, SE, under stairs Not Analyzed gravimetric reduction

Disclaimer: Due to the nature of the EPA 600 method, asbestos may not be detected in samples containing low levels of asbestos. We strongly recommend that analysis of floor tiles, vermiculite, and/or heterogenous soil samples be conducted by TEM for confirmation of "None Detected" by PLM. This report relates only to the samples tested and may not be reproduced, except in full, without the written approval of SAI. This report may not be used by the client to claim product endorsement by NVLAP or any other agency of the U.S. government. Analytical uncertainty available upon request. Scientific Analytical Institute participates in the NVLAP Proficiency Testing program.

Unless otherwise noted blank sample correction was not performed. Estimated MDL is 0.1%.

Heather Boykin (51)

Page 6 of 7P-F-002 r15 1/15/2028 Scientific Analytical Institute, Inc. 4604 Dundas Dr. Greensboro, NC 27407 (336) 292-3888

EPA Method: 600/R-93/116 and

40 CFR, Part 763, Subpart E, App.E

Lab Order ID:Attn: 10066533Customer: RPF Environmental Inc.

320 1st NH Turnpike Northwood, NH 03261

Analysis:

Date Received:

Sean Smith

PLM

10/25/2024

Project: 230534 Togus VA Medical Center, Augusta,ME

Date Reported: 10/29/2024

Sample ID

Lab Sample ID

Description

Lab Notes Asbestos

Fibrous Components

Non-Fibrous Components Treatment

Attributes

102224-HG17a

10066533_0049

Floor tile & mastic, tan/white/dark brown, between rooms? 206 & 208, under staircase Not Analyzed gravimetric reduction

102224-HG17b

10066533_0050

Floor tile & mastic, tan/white/dark brown, in front of entrance to 206, beside heater 3% Chrysotile 97% Other

Non-Fibrous

Dissolved

Black

Homogeneous

102224-HG17c

10066533_0051

Floor tile & mastic, tan/white/dark brown, between rooms? 206 & 208, under staircase Not Analyzed gravimetric reduction

Disclaimer: Due to the nature of the EPA 600 method, asbestos may not be detected in samples containing low levels of asbestos. We strongly recommend that analysis of floor tiles, vermiculite, and/or heterogenous soil samples be conducted by TEM for confirmation of "None Detected" by PLM. This report relates only to the samples tested and may not be reproduced, except in full, without the written approval of SAI. This report may not be used by the client to claim product endorsement by NVLAP or any other agency of the U.S. government. Analytical uncertainty available upon request. Scientific Analytical Institute participates in the NVLAP Proficiency Testing program.

Unless otherwise noted blank sample correction was not performed. Estimated MDL is 0.1%.

Heather Boykin (51)

Page 7 of 7P-F-002 r15 1/15/2028 Scientific Analytical Institute, Inc. 4604 Dundas Dr. Greensboro, NC 27407 (336) 292-3888

Gravimetric Reduction EPA Method: 600/R-93/116 and 600/M4-82-020

Lab Order ID:Attn: 10067077Customer: RPF Environmental Inc.

320 1st NH Turnpike Northwood, NH 03261

Analysis:

Date Received:

Nick Howard

PGR

10/31/2024

Project: 230534 Togus VA Medical Center, Augusta, ME

Date Reported: 11/05/2024

Sample ID

Lab Sample ID

Description

Lab Notes

Asbestos ( Wt. % )

Acid Soluble ( Wt. % )

Other Non-Asbestos

( Wt. % )

Organic ( Wt. % )

102424-HG 104A

- A

10067077_0019

Cove Basel Glue, tan, Bottom of stairs at police station 0% None Detected 47.30%52.70% covebase

102424-HG 104A

- B

10067077_0035

Cove Basel Glue, tan, Bottom of stairs at police station 0% None Detected 36.68%63.32% mastic

102424-HG 104B

- A

10067077_0020

Cove Basel Glue, blue, Northwest, Near entrance to building 209 0% None Detected 37.72%62.28% covebase

102424-HG 104B

- B

10067077_0036

Cove Basel Glue, blue, Northwest, Near entrance to building 209 0% None Detected 32.66%67.34% mastic

102424-HG 104C

- A

10067077_0021

Cove Basel glue, gray, Northeast, front of entrance to building 235 0% None Detected 45.24%54.76% covebase

102424-HG 104C

- B

10067077_0037

Cove Basel glue, gray, Northeast, front of entrance to building 235 0% None Detected 43.98%56.02% mastic

102424-HG 104E

10067077_0022

0% None Detected 56.98%43.02%

Disclaimer: This report relates only to the samples tested and may not be reproduced, except in full, without the written approval of SAI. This report may not be used by the client to claim product endorsement by NVLAP or any other agency of the U.S. government. Estimated MDL is 0.1%.

Byron Stroble (7)

Page 1 of 1P-F-004 r17 2/28/2027 Scientific Analytical Institute, Inc. 4604 Dundas Dr. Greensboro, NC 27407 (336) 292-3888

EPA Method: 600/R-93/116 and

40 CFR, Part 763, Subpart E, App.E

Lab Order ID:Attn: 10067077Customer: RPF Environmental Inc.

320 1st NH Turnpike Northwood, NH 03261

Analysis:

Date Received:

Nick Howard

PLM

10/31/2024

Project: 230534 Togus VA Medical Center, Augusta, ME

Date Reported: 11/05/2024

Sample ID

Lab Sample ID

Description

Lab Notes Asbestos

Fibrous Components

Non-Fibrous Components Treatment

Attributes

102424-HG 101A

10067077_0001

Gypsum & compound, Gray/ white finish, South of room

104 None Detected 10% Cellulose 90% Other

Non-Fibrous

Teased

Brown, White

Heterogeneous gypsum board:none detect; joint compound:none detect

102424-HG 101B

10067077_0002

Gypsum & compound, Gray/ white finish, Northeast wall, near patriot clips None Detected 10% Cellulose 90% Other

Non-Fibrous

Teased

Brown, White

Heterogeneous gypsum board:none detect; joint compound:none detect

102424-HG 101C

10067077_0003

Gypsum & compound, Gray/ white finish, east wall, near enterance to bulding 203 None Detected 10% Cellulose 90% Other

Non-Fibrous

Teased

Brown, White

Heterogeneous gypsum board:none detect; joint compound:none detect

102424-HG 101D

10067077_0004

Gypsum & compound, Gray/ white finish.ceiling, front of room 7 None Detected 10% Cellulose 90% Other

Non-Fibrous

Teased

Brown, White

Heterogeneous gypsum board:none detect; joint compound:none detect

102424-HG 101E

10067077_0005

Gypsum & compound, Gray/ white finish, Northeast, front of enteracne to building 235 None Detected 10% Cellulose 90% Other

Non-Fibrous

Teased

Brown, White

Heterogeneous gypsum board:none detect; joint compound:none detect

102424-HG 101F

10067077_0006

Gypsum & compound, Gray/ white finish, Northeast, enterance to building 204 None Detected 10% Cellulose 90% Other

Non-Fibrous

Teased

Brown, White

Heterogeneous gypsum board:none detect; joint compound:none detect

102424-HG 101G

10067077_0007

Gypsum & compound, Gray/ white finish, South wall, front of room 132F None Detected 10% Cellulose 90% Other

Non-Fibrous

Teased

Brown, White

Heterogeneous gypsum board:none detect; joint compound:none detect

102424-HG 102A -

A

10067077_0008

Plaster, gray & white finish, stairs 1, under staircase, None Detected 100% Other

Non-Fibrous

Crushed

White

Homogeneous finish

Disclaimer: Due to the nature of the EPA 600 method, asbestos may not be detected in samples containing low levels of asbestos. We strongly recommend that analysis of floor tiles, vermiculite, and/or heterogenous soil samples be conducted by TEM for confirmation of "None Detected" by PLM. This report relates only to the samples tested and may not be reproduced, except in full, without the written approval of SAI. This report may not be used by the client to claim product endorsement by NVLAP or any other agency of the U.S. government. Analytical uncertainty available upon request. Scientific Analytical Institute participates in the NVLAP Proficiency Testing program.

Unless otherwise noted blank sample correction was not performed. Estimated MDL is 0.1%.

Byron Stroble (37)

Page 1 of 5P-F-002 r15 1/15/2028 Scientific Analytical Institute, Inc. 4604 Dundas Dr. Greensboro, NC 27407 (336) 292-3888

EPA Method: 600/R-93/116 and

40 CFR, Part 763, Subpart E, App.E

Lab Order ID:Attn: 10067077Customer: RPF Environmental Inc.

320 1st NH Turnpike Northwood, NH 03261

Analysis:

Date Received:

Nick Howard

PLM

10/31/2024

Project: 230534 Togus VA Medical Center, Augusta, ME

Date Reported: 11/05/2024

Sample ID

Lab Sample ID

Description

Lab Notes Asbestos

Fibrous Components

Non-Fibrous Components Treatment

Attributes

102424-HG 102A -

B

10067077_0023

Plaster, gray & white finish, stairs 1, under staircase, None Detected 100% Other

Non-Fibrous

Crushed

Gray

Homogeneous base

102424-HG 102B -

A

10067077_0009

Plaster, gray & white finish, Southeast, middle of hallway

None Detected 100% Other

Non-Fibrous

Teased

White

Homogeneous compound

102424-HG 102B -

B

10067077_0024

Plaster, gray & white finish, Southeast, middle of hallway

None Detected 100% Other

Non-Fibrous

Crushed

White

Homogeneous finish

102424-HG 102B -

C

10067077_0025

Plaster, gray & white finish, Southeast, middle of hallway

None Detected 100% Other

Non-Fibrous

Crushed

Gray

Homogeneous base

102424-HG 102C -

A

10067077_0010

Plaster, gray & white finish, Northwest wall, under hearter

None Detected 100% Other

Non-Fibrous

Teased

White

Homogeneous compound

102424-HG 102C -

B

10067077_0026

Plaster, gray & white finish, Northwest wall, under hearter

None Detected 100% Other

Non-Fibrous

Crushed

White

Homogeneous finish

102424-HG 102C -

C

10067077_0027

Plaster, gray & white finish, Northwest wall, under hearter

None Detected 100% Other

Non-Fibrous

Crushed

Gray

Homogeneous base

102424-HG 102D

- A

10067077_0011

Plaster, gray & white finish, East wall, Entracne to building 21 0 None Detected 100% Other

Non-Fibrous

Teased

White

Homogeneous compound

Disclaimer: Due to the nature of the EPA 600 method, asbestos may not be detected in samples containing low levels of asbestos. We strongly recommend that analysis of floor tiles, vermiculite, and/or heterogenous soil samples be conducted by TEM for confirmation of "None Detected" by PLM. This report relates only to the samples tested and may not be reproduced, except in full, without the written approval of SAI. This report may not be used by the client to claim product endorsement by NVLAP or any other agency of the U.S. government. Analytical uncertainty available upon request. Scientific Analytical Institute participates in the NVLAP Proficiency Testing program.

Unless otherwise noted blank sample correction was not performed. Estimated MDL is 0.1%.

Byron Stroble (37)

Page 2 of 5P-F-002 r15 1/15/2028 Scientific Analytical Institute, Inc. 4604 Dundas Dr. Greensboro, NC 27407 (336) 292-3888

EPA Method: 600/R-93/116 and

40 CFR, Part 763, Subpart E, App.E

Lab Order ID:Attn: 10067077Customer: RPF Environmental Inc.

320 1st NH Turnpike Northwood, NH 03261

Analysis:

Date Received:

Nick Howard

PLM

10/31/2024

Project: 230534 Togus VA Medical Center, Augusta, ME

Date Reported: 11/05/2024

Sample ID

Lab Sample ID

Description

Lab Notes Asbestos

Fibrous Components

Non-Fibrous Components Treatment

Attributes

102424-HG 102D

- B

10067077_0028

Plaster, gray & white finish, East wall, Entracne to building 21 0 None Detected 100% Other

Non-Fibrous

Crushed

White

Homogeneous finish

102424-HG 102D

- C

10067077_0029

Plaster, gray & white finish, East wall, Entracne to building 21 0 None Detected 100% Other

Non-Fibrous

Crushed

Gray

Homogeneous base

102424-HG 102E -

A

10067077_0012

Plaster, gray & white finish, South wall, front of room

132F None Detected 100% Other

Non-Fibrous

Teased

White

Homogeneous compound

102424-HG 102E -

B

10067077_0030

Plaster, gray & white finish, South wall, front of room

132F None Detected 100% Other

Non-Fibrous

Crushed

White

Homogeneous finish

102424-HG 102E -

C

10067077_0031

Plaster, gray & white finish, South wall, front of room

132F None Detected 100% Other

Non-Fibrous

Crushed

Gray

Homogeneous base

102424-HG 102F -

A

10067077_0013

Plaster, gray & white finish, Northwest comer, entracne to mailroom None Detected 100% Other

Non-Fibrous

Teased

White

Homogeneous compound

102424-HG 102F -

B

10067077_0032

Plaster, gray & white finish, Northwest comer, entracne to mailroom None Detected 100% Other

Non-Fibrous

Crushed

White

Homogeneous finish

102424-HG 102F -

C

10067077_0033

Plaster, gray & white finish, Northwest comer, entracne to mailroom None Detected 100% Other

Non-Fibrous

Crushed

Gray

Homogeneous base

Disclaimer: Due to the nature of the EPA 600 method, asbestos may not be detected in samples containing low levels of asbestos. We strongly recommend that analysis of floor tiles, vermiculite, and/or heterogenous soil samples be conducted by TEM for confirmation of "None Detected" by PLM. This report relates only to the samples tested and may not be reproduced, except in full, without the written approval of SAI. This report may not be used by the client to claim product endorsement by NVLAP or any other agency of the U.S. government. Analytical uncertainty available upon request. Scientific Analytical Institute participates in the NVLAP Proficiency Testing program.

Unless otherwise noted blank sample correction was not performed. Estimated MDL is 0.1%.

Byron Stroble (37)

Page 3 of 5P-F-002 r15 1/15/2028 Scientific Analytical Institute, Inc. 4604 Dundas Dr. Greensboro, NC 27407 (336) 292-3888

EPA Method: 600/R-93/116 and

40 CFR, Part 763, Subpart E, App.E

Lab Order ID:Attn: 10067077Customer: RPF Environmental Inc.

320 1st NH Turnpike Northwood, NH 03261

Analysis:

Date Received:

Nick Howard

PLM

10/31/2024

Project: 230534 Togus VA Medical Center, Augusta, ME

Date Reported: 11/05/2024

Sample ID

Lab Sample ID

Description

Lab Notes Asbestos

Fibrous Components

Non-Fibrous Components Treatment

Attributes

102424-HG 102G

- A

10067077_0014

Plaster, gray & white finish, South wall, front of police station None Detected 100% Other

Non-Fibrous

Crushed

White

Homogeneous finish

102424-HG 102G

- B

10067077_0034

Plaster, gray & white finish, South wall, front of police station None Detected 100% Other

Non-Fibrous

Crushed

Gray

Homogeneous bae

102424-HG 103A

10067077_0015

Pin hole/ceiling tile, white, front of police station

None Detected 45% 45%

Cellulose Mineral Wool

10% Other

Fibrous

Ashed, Teased

White, Gray

Homogeneous

102424-HG 103C

10067077_0016 textured/ ceiling tile, white, Northwest, front of room 18

None Detected 45% 45%

Cellulose Mineral Wool

10% Other

Fibrous

Ashed, Teased

Gray, White

Homogeneous

102424-HG 103D

10067077_0017 double dot/ ceiling tile, white, north, front of rom 20

None Detected 45% 45%

Mineral Wool Cellulose

10% Other

Fibrous

Teased, Ashed

White, Gray

Homogeneous

102424-HG 103E

10067077_0018

Deep fissured/ ceiling tile, white, Northeast, front of room 24 None Detected 80% 10%

Mineral Wool Cellulose

10% Other

Fibrous

Ashed, Teased

White, Gray

Homogeneous

102424-HG 104A -

A

10067077_0019

Cove Basel Glue, tan, Bottom of stairs at police station

Not Analyzed cove base-gravimetric reduction

102424-HG 104A -

B

10067077_0035

Cove Basel Glue, tan, Bottom of stairs at police station

Not Analyzed mastic-gravimetric reduction

Disclaimer: Due to the nature of the EPA 600 method, asbestos may not be detected in samples containing low levels of asbestos. We strongly recommend that analysis of floor tiles, vermiculite, and/or heterogenous soil samples be conducted by TEM for confirmation of "None Detected" by PLM. This report relates only to the samples tested and may not be reproduced, except in full, without the written approval of SAI. This report may not be used by the client to claim product endorsement by NVLAP or any other agency of the U.S. government. Analytical uncertainty available upon request. Scientific Analytical Institute participates in the NVLAP Proficiency Testing program.

Unless otherwise noted blank sample correction was not performed. Estimated MDL is 0.1%.

Byron Stroble (37)

Page 4 of 5P-F-002 r15 1/15/2028 Scientific Analytical Institute, Inc. 4604 Dundas Dr. Greensboro, NC 27407 (336) 292-3888

EPA Method: 600/R-93/116 and

40 CFR, Part 763, Subpart E, App.E

Lab Order ID:Attn: 10067077Customer: RPF Environmental Inc.

320 1st NH Turnpike Northwood, NH 03261

Analysis:

Date Received:

Nick Howard

PLM

10/31/2024

Project: 230534 Togus VA Medical Center, Augusta, ME

Date Reported: 11/05/2024

Sample ID

Lab Sample ID

Description

Lab Notes Asbestos

Fibrous Components

Non-Fibrous Components Treatment

Attributes

102424-HG 104B -

A

10067077_0020

Cove Basel Glue, blue, Northwest, Near entrance to building 209 Not Analyzed cove base-gravimetric reduction

102424-HG 104B -

B

10067077_0036

Cove Basel Glue, blue, Northwest, Near entrance to building 209 Not Analyzed mastic-gravimetric reduction

102424-HG 104C -

A

10067077_0021

Cove Basel glue, gray, Northeast, front of entrance to building 235 Not Analyzed cove base-gravimetric reduction

102424-HG 104C -

B

10067077_0037

Cove Basel glue, gray, Northeast, front of entrance to building 235 Not Analyzed mastic-gravimetric reduction

102424-HG 104E

10067077_0022

Not Analyzed gravimetric reduction

Disclaimer: Due to the nature of the EPA 600 method, asbestos may not be detected in samples containing low levels of asbestos. We strongly recommend that analysis of floor tiles, vermiculite, and/or heterogenous soil samples be conducted by TEM for confirmation of "None Detected" by PLM. This report relates only to the samples tested and may not be reproduced, except in full, without the written approval of SAI. This report may not be used by the client to claim product endorsement by NVLAP or any other agency of the U.S. government. Analytical uncertainty available upon request. Scientific Analytical Institute participates in the NVLAP Proficiency Testing program.

Unless otherwise noted blank sample correction was not performed. Estimated MDL is 0.1%.

Byron Stroble (37)

Page 5 of 5P-F-002 r15 1/15/2028 Scientific Analytical Institute, Inc. 4604 Dundas Dr. Greensboro, NC 27407 (336) 292-3888

APPENDIX B

PHOTOGRAPHS

Site Address:

1 VA Center, Augusta, ME 04330 www.airpf.com 603-942-5432

Project No. 230534

1. 12” White and gold swirl floor tile, front of room 118, Prime 1 2. 12” white, and purple watercolor floor tile, southwest, near room 132F, prime 3

3. 12” blue floor tile, front of exit, near building 206, prime 5 4. 12” green and purple wavey tile, entrance to building 232, prime 4 www.airpf.com

5. 12” White and tan Mult floor tile, prime 6 6. 12” White and blue Mult, southeast, of chaple, front f building 248

7. 12” light and gray grain floor tile, southeast front of entrance to building 153, prime 16 8. 12” Dark yellow floor tile, front of entrance to building

200, prime 13 www.airpf.com

9. 12” light yellow, white grain floor tile, front of toom 25, entrance to building 200, prime 13 10. 12” tan, white and dark brown gran floor tile, between buildings 206 & 208, prime 17

APPENDIX C

Conner Callout Prime 1

HG1A, HG1B, HG1C

Conner Rectangle

Conner Rectangle

Conner Callout Prime 2

HG2A

HG2B

HG2C

Conner Rectangle

Conner Callout Prime 3

HG3A

HG3B

HG2C

Conner Rectangle

Conner Callout Prime 4

HG4A

HG4B

HG4C

Conner Rectangle

Conner Callout Prime 5

HG5A

HG5B

HG5C

Conner Rectangle

Conner Callout Prime 17

HG17A

HG17B

HG17C

Conner Rectangle

Conner Callout Prime 6

Conner Rectangle

Conner Callout Prime 7

Conner Rectangle

Conner Callout Prime 8

Conner Rectangle

Conner Callout Skipped

Conner Rectangle

Conner Callout Prime 9

Conner Polyline

Conner Callout Prime 10

Conner Polyline

Conner Callout Prime 11

Conner Rectangle

Conner Rectangle

Conner Rectangle

Conner Rectangle

Conner Callout Prime 12

Conner Callout Prime 15

HG15A

HG15B

HG15C

Conner Line

Conner Callout Prime 13

Conner Callout Prime 14

HG14A

HG14B

HG14C

Conner Callout Prime 16

HG16A

HG16B

HG15C

Callout Prime 1

Conner Rectangle

Conner Rectangle

Conner Callout Prime 2

Conner Rectangle

Conner Callout Prime 3

Conner Rectangle

Conner Callout Prime 4

Conner Rectangle

Conner Callout Prime 5

Conner Rectangle

Conner Callout Prime 17

Conner Rectangle

Conner Callout Prime 6

Conner Rectangle

Conner Callout Prime 7

Conner Rectangle

Conner Callout Prime 8

Conner Callout Skipped

Conner Rectangle

Conner Callout Prime 9

Conner Polyline

Conner Callout Prime 10

Conner Polyline

Conner Callout Prime 11

Conner Rectangle

Conner Rectangle

Conner Rectangle

Conner Rectangle

Conner Callout Prime 12

Conner Callout Prime 16

Conner Callout Prime 15

Conner Line

Conner Callout Prime 13

Conner Callout Prime 14

Conner Polyline

Conner Polyline

Conner Polyline

Conner Polyline

Conner Rectangle

Conner Rectangle

Conner Line

Conner Textbox Key

Conner Textbox Sections -

Conner Rectangle

Conner Textbox Plaster walls -

Conner Line

Conner Textbox Plaster ceiling -

Line

APPENDIX D

LIMITATIONS

1. The observations and conclusions presented in the Report were based solely upon the services described herein, and not on scientific tasks or procedures beyond the RPF Environmental, Inc. Scope of Work

(SOW) as discussed in the proposal and/or agreement. The conclusions and recommendations are based on visual observations and testing, limited as indicated in the Report, and were arrived at in accordance with generally accepted standards of industrial hygiene practice and asbestos professionals. The nature of this survey or monitoring service was limited as indicated herein and in the report or letter of findings.

Further testing, survey, and analysis is required to provide more definitive results and findings.

2. For site survey work, observations were made of the designated accessible areas of the site as indicated in the Report. While it was the intent of RPF to conduct a survey to the degree indicated, it is important to note that not all suspect ACBM material in the designated areas were specifically assessed and visibility was limited, as indicated, due to the presence of furnishings, equipment, solid walls and solid or suspended ceilings throughout the facility and/or other site conditions. Asbestos or hazardous material may have been used and may be present in areas where detection and assessment is difficult until renovation and/or demolition proceeds. Access and observations relating to electrical and mechanical systems within the building were restricted or not feasible to prevent damage to the systems and minimize safety hazards to the survey team.

3. Although assumptions may have been stated regarding the potential presence of inaccessible or concealed asbestos and other hazardous material, full inspection findings for all asbestos and other hazardous material requires the use of full destructive survey methods to identify possible inaccessible suspect material and this level of survey was not included in the SOW for this project. For preliminary survey work, sampling and analysis as applicable was limited and a full survey throughout the site was not performed. Only the specific areas and /or materials indicated in the report were included in the SOW.

This inspection did not include a full hazard assessment survey, full testing or bulk material, or testing to determine current dust concentrations of asbestos in and around the building. Inspection results should not be used for compliance with current EPA and State asbestos in renovation/demolition requirements unless specifically stated as intended for this use in the RPF report and considering the limitations as stated therein and within this limitations document.

4. Where access to portions of the surveyed area was unavailable or limited, RPF renders no opinion of the condition and assessment of these areas. The survey results only apply to areas specifically accessed by

RPF during the survey. Interiors of mechanical equipment and other building or process equipment may also have asbestos and other hazardous material present and were not included in this inspection. For renovation and demolition work, further inspection by qualified personnel will be required during the course of construction activity to identify suspect material not previously documented at the site or in this survey report. Bordering properties were not investigated and comprehensive file review and research was not performed.

5. For lead in paint, observations were made of the designated accessible areas of the site as indicated in the

Report. Limited testing may have been performed to the extent indicated in the text of the report.

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .