S06 Eaton-93pm-ups-brochure and specs.pdf

PDF 1 MB Posted

Attached to
Y1GC--523A5-24-011 MRI Generator UST
Solicitation number
36C24124B0030
Issued by

About this file

This document is a product brochure for the Eaton 93PM uninterruptible power supply (UPS) system. The 93PM UPS is a three-phase solution designed for data centers, featuring industry-leading efficiency of up to 99% in Energy Saver System (ESS) mode and up to 97% in double-conversion mode. Key features include vertical scalability, internal redundancy, a compact footprint, and easy deployment and management through user-friendly controls and connectivity options. The 93PM supports power capacities from 10-400 kW across 208V, 400V, and 480V configurations, with options for integrated maintenance bypass, distribution cabinets, battery cabinets, and UL 924 certification for emergency lighting applications. The document outlines the 93PM's technical specifications, efficiency savings, and integrated power management capabilities.

The related federal contract opportunity is a solicitation (Solicitation Number: 36C24124B0030) for an MRI Generator Upgrade and Underground Storage Tank (UST) project at the VA Medical Center in Brockton, Massachusetts. The solicitation is an invitation for bid, with the Department of Veterans Affairs as the procuring agency.

View the file

Other files

File Type Posted
S06 RFI 523A5-24-011 MRI Generator UST 5-22-24.pdf.pdf PDF
36C24124B0030 0005.docx DOCX document
S02 MA20240012 03-22-24.pdf PDF
S06 523A5-24-011 Bid Opening Conference line Amend 5.pdf PDF
36C24124B0030 0004.docx DOCX document
36C24124B0030 0003.docx DOCX document
36C24124B0030 0002.docx DOCX document
S02 WD MA20240012 - 4-17-2024.pdf PDF
S06 Site Visit Sign In 523A5-24-011 MRI.pdf PDF
S06 RFI Q-A 523A5-24-011 MRI Generator UST 4-16-24 Final.pdf PDF
S06 Eaton 93PM 180kW 3-Wire Maintenance Bypass Sidecar Installation Information 7-21-16 Red-Lined.pdf PDF
S06 Bid Opening Conference Line 36C24124B0030.pdf PDF
S06 Eaton 93PM 180kW 3-Wire UPS Installation Information 7-29-16 Red Lined.pdf PDF
36C24124B0030 0001.docx DOCX document
36C24124B0030_1 Final Re-Issue.pdf PDF
S02 26321l-Enginer-Generator-Startup_2020-11-30( COR).pdf PDF
S02 A4.1_EnlargedFloorPlans-Level1.pdf PDF
S02 261219-Engine-Generator-Re-Submittal-Review_2018-09-06 (COR).pdf PDF
S02 523A5-24-011 SOW r3 8-24-23.pdf PDF
36C24124B0030_1.docx DOCX document
S02 523A5-24-011 - Emg Gen BOUND DRAWINGS-211221.pdf PDF
S02 MRI Emg Generator Specs.pdf PDF
S02 523A5-24-003_PCRA and ICRA signed.pdf PDF
S02 BLDG 3 Radiology Addition104 E2.03.pdf PDF
Show all 24

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Product brochure 10–400 kW

Eaton 93PM UPS Efficient. Scalable. Innovative.

2 EATON 93PM UPS

The Eaton 93PM UPS combines unprecedented efficiency and reliability with an eye-catching design. A space-saving, scalable and flexible device that’s as easy to deploy as it is to manage, it’s the perfect three-phase white or grey space solution for today’s data center.

93PM features and benefits

Load % Legacy UPS efficiency

93PM ESS

efficiency

93PM ESS

annual savings($)*

93PM double-conversion efficiency

93PM double-conversion annual savings ($)*

25% 84.0% 98.4% $27,470 95.8% $23,121

50% 90.6% 98.9% $29,212 96.8% $22,294

75% 92.5% 99.1% $34,059 97.0% $23,724

100% 93.0% 99.1% $41,746 96.8% $26,623

* Savings calculated using $0.10 kW/hr. and 80% cooling ratio (currency in US dollars) ** Table data is specific to the 480V 93PM UPS

Table showing 400 kW efficiency savings comparison**

The 93PM’s vertical scalability, internal redundancy and compact footprint design

1. Lowest TCO (Total Cost of Ownership)

• Conserves valuable data center floor space with its compact footprint and internal redundancy design

• Reduces cost and unexpected future growth risks with its vertical scalability, enabling you to scale as you grow

• Reduces power and cooling OPEX through industry-leading energy-efficiency

• 99% efficiency with ESS

• Up to 97% efficiency in double-conversion mode

The 93PM ESS energy cost savings pay for the UPS in less than 3 years.

Calculate your 93PM savings with ESS at Eaton.com/ESS.

The 93PM double-conversion energy savings pay for the UPS in less than 3 years.

Eaton 93PM efficiency in double conversion and ESS UPS load (%)

U P

S e ff ic ie n cy

10 20 30 40 50 60 70 80 90 100

ESS

Double-conversion mode

Legacy UPS

Typical Operating Range

Eaton UPS with redundancy

Redundant 50 kW

50 kW

50 kW

93PM

battery cabinet

93PM

redundant

UPS

93PM

maintenance bypass

93PM

distribution cabinet

Legacy system with UPS redundancy http://Eaton.com/ESS

3EATON 93PM UPS

2. Easy deployment

• Maximizes deployment flexibility by providing flexible configurability

The 93PM also supports front-to-back ventilation making it great for hot/ cold aisle configuration.

The 93PM supports front-to-top ventilation, ideal for against the wall configuration.

Front-to-top ventilation feature also makes the 93PM a perfect fit for in-row configurations that support slim chimneys.

4 EATON 93PM UPS

3. Easy management

• Provides easier access to detailed status information through its large, user-friendly LCD touchscreen interface

With the 93PM’s graphical LCD interface you can track stats on energy savings, battery time, outage tracking, load profiling and much more.

The green/yellow/red LED light-bars make system status visible from a distance in data centers.

• Integrates with the leading virtual platforms through its full suite of power management and connectivity software

Designed for the most advanced IT environments, the 93PM supports optional communication cards that allow remote access via the HTTP(S), SNMP, MODBUS TCP/IP, Modbus RTU and BACnet IP protocols. In addition, Eaton’s Power Xpert® software and Intelligent Power® Software Suite give you all the tools you need to manage power devices in your physical or virtual environment.

Learn more at Eaton.com/intelligentpower.

• Increases uptime through its 24x7 remote monitoring and reporting capabilities

Eaton’s PredictPulse™ remote monitoring and management service provides real-time monitoring of the 93PM and alerts service technicians to take necessary measures when a problem is detected. Learn more at Eaton.com/PredictPulse.

LED

light bars

Red light bars showing alerts on system. Yellow light bars indicate battery and bypass status.

Communication card

Intelligent Power Manager® (IPM) is a world class power management software platform. It seamlessly monitors power and environmental conditions while providing business continuity for workloads using VMware®, Citrix® and Microsoft® platforms.

IPM also optimizes power and environmental conditions for data centers using OpenStack® or HPE OneView®.

Green light bars showing healthy UPS

Connectivity options:

• Power Xpert Gateway Mini-slot communication card

• Industrial relay card http://Eaton.com/intelligentpower http://Eaton.com/PredictPulse

5EATON 93PM UPS

A

B C

D

I

J

E F G

H

Overhead cable management solutions

Thermal management solutions

Busway ePDUs

Aisle based power management solutions (UPSs)

Rack monitoring solutions

Rack-based power management solutions (UPSs)

IT enclosures

Customized service plans

Management software

A

B

C F

G D

E

H

I

J

Eaton’s comprehensive portfolio Integrated data center products and services

Eaton.com/datacenters http://Eaton.com/datacenters

Eaton, ABM, Intelligent Power Manager, Power Xpert and PredictPulse are registered trademarks.

All other trademarks are property of their respective owners.

Eaton 1000 Eaton Boulevard Cleveland, OH 44122 United States Eaton.com

© 2019 Eaton All Rights Reserved Printed in USA

BR153033EN / GG

January 2019

A

B

C

D

E

F

Cable entry Top and bottom cable entry options available

Communications and connectivity

• Built-in device and host USB

• Five alarm inputs and dedicated EPO

• Alarm relay output

• Four communication slots

Serviceable redundant fan assembly Contained within each power module

Swappable power modules (50 kW) with independent control and power

Soft start controls Contained within each power module

Input/output connections

Learn more at Eaton.com/93PM

EATON 93PM UPS TECHNICAL SPECIFICATIONS*

Power modules Power offering (kW) 10–200 kW in 5 kW increments at 208/220V

20–160 kW in 10 kW increments at 400V 20–200 kW in 10 kW increments at 480V 200–400 kW in 50 kW increments at 480V (optional internal redundancy available)

General characteristics

Efficiency in Energy Saver System (ESS)

Up to 99%

Efficiency in double-conversion mode

Up to 97%

Parallel capability Four distributed, contact factory for more information

Input characteristics 480V models 400V models 208V models

Voltage 480/277V 4-wire 480V 3-wire

380/220V 4-wire 400/230V 4-wire 415/240V 4-wire

208/120V 4-wire 220/127V 4-wire

Voltage range: +10%/-15% +10%/-10% +15%/-15% @ 208V, +10%/-15% @ 220V

Frequency range 50/60 Hz 50/60 Hz 50/60 Hz

Power factor > .99 > .99 > .99

Input current distortion < 3% @ 100% load capacity

< 3% @ 100% load capacity

≤ 3.5% @ 100% load capacity

Battery 480V models 400V models 208V models

Battery voltage 432V, 480V 480V 480V

Charging method ABM® or float technology

ABM® or float technology

ABM or float technology

Output 480V models 400V models 208V models

Voltage 480 3-phase 3-wire or 4-wire 208/120V with IAC-D up to 200 kW

380V, 400V or 415V 3-phase 3-wire or 4-wire

208V or 220V 3-phase 3-wire or 4-wire

Frequency range 50/60 Hz 50/60 Hz 50/60 Hz

Regulation ±1% steady state ±1% steady state ±1% steady state

Voltage THD < 1% (100% linear load) < 5% (non-linear load)”

< 1% (100% linear load) < 5% (non-linear load)”

< 1.6% (100% linear load) < 5% (non-linear load)

Load power factor range Unity with the ability to support 0.8 leading to 0.8 lagging without de-rating

Unity with the ability to support 0.8 leading to 0.8 lagging without de-rating

Unity with the ability to support 0.8 leading to 0.8 lagging without de-rating

Certification 480V models 400V models 208V models Safety UL 1778, cULus, UL 924 Emergency, UL 924 Auxiliary

UL 1778, cULus UL 1778, cULus

EMC FCC Part 15 subpart B class A

FCC Part 15 subpart B class A

FCC Part 15 subpart B class A

Surge IEC 61000-4-5 IEC 61000-4-5 IEC 61000-4-5

Optional accessories

• Integrated maintenance bypass

• Integrated distribution cabinet (with input and output transformer options)

• Integrated power distribution cabinet

• Integrated parallel tie cabinet

• Integrated battery cabinet (small and large)

• Wall mounted or floor mounted bypass

• Lithium battery cabinet

UL 924 certification

The 93PM meets the strict standards for UL 924 compliance for emergency lighting applications when ordered with an emergency lighting SKU.

For more information, visit Eaton.com/UL924UPS

UPS dimensions

Height 74"

Depth 42"

Width 22” 20–150 kW (480V), 20-120 kW (400V) and 10–120 kW (208/220V)

32” 160–200 kW (480V) and 120-160 kW (400V) 34.4" 10–160 kW (208/220V) 43.3" 10–200 kW (208/220V) 64" 250–400 kW (480V)

* Due to continued improvements, specifications are subject to change.

The functional core of the 93PM UPS

B A

D E

Open front view of 400 kW unit

F

C http://Eaton.com http://Eaton.com/93PM http://Eaton.com/UL924UPS