About this file
This is a structural permit set of drawings for a new 28,000 square-foot recreation center to be constructed in Palm Harbor, Florida for Pinellas County Parks and Recreation. The project is located at 1500 16th Street, Palm Harbor, Florida 34683, and is designed to serve dual purposes as a community recreational facility and an at-risk hurricane shelter capable of accommodating approximately 800 general population shelter spaces during storms. The facility will replace an existing building originally constructed in 1979 and is intended to serve approximately 60,000 residents of unincorporated Palm Harbor. The project includes comprehensive structural systems consisting of cast-in-place concrete foundations and slabs, concrete and masonry walls, composite metal floor decking with concrete topping, open web steel joists, and structural steel framing. The contract term is established for 425 consecutive calendar days from the Notice to Proceed, with liquidated damages assessed at $487.07 per calendar day for delays. A non-mandatory site visit and pre-bid conference are scheduled for October 29, 2025, with questions from potential bidders due by November 4, 2025. Bid submission deadlines are November 11, 2025 for Step 1 and November 20, 2025 for Step 2 of the two-step qualification process.
The structural design incorporates the Florida Building Code (Eighth Edition 2023), with wind design for basic wind speeds of 170 mph ultimate and 132 mph allowable stress design, and the facility is designed as a hurricane storm shelter in accordance with ICC 500-20 standards. Design standards include ACI 318-19 for reinforced concrete, TMS 402-16 for masonry, AISC 360-16 for structural steel, and ASCE 7-22 for minimum design loads. The project includes allowances of 25 cubic yards of 4,000 PSI structural concrete, 2 tons of reinforced steel, and 2 tons of structural steel framing, with the contractor required to credit the owner for any unused portions. A qualified special inspector registered as a Florida professional engineer must be retained to verify that the primary structural frame is constructed in substantial accordance with the permitted contract documents. The contractor is responsible for all dimensional coordination and must verify all dimensions and details before proceeding with work, with any discrepancies brought to the immediate attention of the architect and engineers. Shop drawings must be submitted electronically in PDF format, with a minimum of 10 working days for engineer review, plus additional time required for architectural and owner review.
View the file
Other files for this state and local contract opportunity
Show all 50
Palm Harbor Recreation Center Addition has more files on GovTribe.
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
GENERAL STRUCTURAL NOTES
GENERAL NOTES:
1. CONTRACTOR IS RESPONSIBLE FOR AND SHALL VERIFY AND COORDINATE ALL
DIMENSIONS AND DETAILS BEFORE PROCEEDING WITH WORK. ANY DISCREPANCIES
SHALL BE BROUGHT TO THE IMMEDIATE ATTENTION OF THE ARCHITECT AND ENGINEERS.
2. DETAILS SHOWN IN ANY SECTION APPLY TO ALL SIMILAR SECTIONS AND CONDITIONS
UNLESS NOTED OTHERWISE.
3. CONTRACTOR SHALL FULLY BRACE AND OTHERWISE PROTECT ALL WORK IN PROGRESS
UNTIL THE BUILDING IS COMPLETED.
4. ALL STRUCTURAL ITEMS FOR THIS PROJECT HAVE BEEN DESIGNED IN
ACCORDANCE WITH APPROPRIATE PROVISIONS OF EACH OF THE
FOLLOWING:
A. THE FLORIDA BUILDING CODE, (EIGHTH EDITION) 2023.
B. ACI STANDARD 318-19 BUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE.
C. BUILDING CODE REQUIREMENTS FOR MASONRY STRUCTURES (TMS 402-16).
D. AISC "SPECIFICATION FOR THE DESIGN, FABRICATION AND ERECTION OF
STRUCTURAL STEEL FOR BUILDINGS" 360-16.
E. ASCE 7-22 "MINIMUM DESIGN LOADS FOR BUILDINGS AND OTHER STRUCTURES".
F. 2020 ICC 500 ICC/NSSA STANDARD FOR THE DESIGN AND CONSTRUCTION OF STORM
SHELTERS.
5. THE STRUCTURAL DRAWINGS SHALL BE USED IN CONJUNCTION WITH THE
SPECIFICATIONS AND THE ARCHITECTURAL AND MECHANICAL DRAWINGS. IF THERE IS A
DISCREPANCY BETWEEN DRAWINGS, IT IS THE CONTRACTOR'S RESPONSIBILITY TO
NOTIFY THE ARCHITECT PRIOR TO PERFORMING WORK.
6. IN CASE OF CONFLICT BETWEEN TYPICAL DETAILS, PROJECT SECTIONS, AND/OR DETAILS, THE MOST STRINGENT CONDITION SHALL APPLY.
7. ALL DIMENSIONS MUST BE COORDINATED WITH ARCHITECTURAL DRAWINGS AND WITH
EQUIPMENT MANUFACTURER (I.E. WINDOW, DOOR, AIR HANDLER, ETC.). CONTRACTOR
MUST OBTAIN AN ARCHITECTURAL DIRECTIVE IN CASE OF ANY CONFLICT. REFER TO
ARCHITECTURAL DRAWINGS FOR DIMENSIONS NOT SHOWN IN STRUCTURAL DRAWINGS.
8. ROOFTOP EQUIPMENT ANCHORAGE & OUTDOOR RACK MOUNTED EQUIPMENT
ANCHORAGE. ALL ROOF TOP EQUIPMENT CURBS, ROOF TOP MECHANICAL EQUIPMENT,
EQUIPMENT TIE DOWNS, AND CONNECTIONS OF ALL EQUIPMENT TO OUTDOOR RACKS OR
BUILDING STRUCTURE FOR WIND LOADING ARE TO BE DESIGNED AND ENGINEERED BY A
REGISTERED SPECIALTY ENGINEER RETAINED BY THE MECHANICAL EQUIPMENT
SUPPLIER. SIGNED AND SEALED DRAWINGS AND CALCULATIONS ARE TO BE SUBMITTED
TO THE ENGINEER OF RECORD FOR REVIEW AND APPROVAL. THE EQUIPMENT
MANUFACTURER SHALL PROVIDE THE ATTACHMENT OF THE UNIT TO THE STRUCTURE
AND SUBMIT TO THE ENGINEER LOADS, LOCATIONS, AND METHODS OF ATTACHMENT. THE
STRUCTURAL ENGINEER WILL MAKE PROVISIONS IN THE DESIGN OF THE PRIMARY
STRUCTURAL FRAME TO ACCOMMODATE THE LOADS AND ATTACHMENTS SUBMITTED BY
THE MANUFACTURER.
9. ALLOWANCES FOR THIS PROJECT:
A. 25 CUBIC YARDS OF 4,000 PSI STRUCTURAL CONCRETE.
B. 2 TONS REINFORCED STEEL.
C. 2 TONS STRUCTURAL STEEL FRAMING.
D. ALLOWANCES SHALL INCLUDE ALL COST OF MATERIALS AND LABOR.
E. CONTRACTOR SHALL GIVE CREDIT TO OWNER FOR ANY UNUSED PORTION OF THIS
ALLOWANCE AT THE END OF THE PROJECT.
CONCRETE AND REINFORCING:
1. ALL CONCRETE WORK SHALL CONFORM TO THE LATEST ACI "BUILDING CODE
REQUIREMENTS FOR REINFORCED CONCRETE, ACI-318".
2. ALL CONCRETE SHALL HAVE A MINIMUM 28-DAY COMPRESSIVE STRENGTHS AS
INDICATED BELOW:
CONCRETE MAX WATER TYPE
STRENGTH CEMENT RATIO AGGREGATE LOCATION USED
5000 PSI 0.42 STONE CONCRETE U.N.O.
4000 PSI 0.45 STONE FOUNDATIONS
3000 PSI 0.52 STONE SLAB ON GRADE
3. IN CASE A LIGHT WEIGHT MIX IS SPECIFIED, THE STRENGTH AND WATER CEMENT RATIO
SHOULD BE AS INDICATED IN THE TABLE ABOVE.
4. STRUCTURAL LIGHT WEIGHT CONCRETE SHOULD HAVE A DENSITY BETWEEN 80 PCF
AND 115 PC.
5. ALL REINFORCING STEEL SHALL BE INTERMEDIATE GRADE, NEW BILLET STEEL,
DEFORMED BARS, CONFORMING TO ASTM A-615, GRADE 60. ALL BARS SHALL BE
SECURELY SUPPORTED AND WIRED IN PLACE. PRIOR TO POURING CONCRETE. ALL
REINFORCING STEEL TO BE WELDED SHALL CONFORM TO ASTM A-706.
6. ALL WELDED WIRE FABRIC (W.W.F.) IN FLAT SHEETS ONLY AND SHALL CONFORM TO
ASTM A-185.
7. UNLESS NOTED, ALL BARS MARKED CONTINUOUS SHALL BE SPLICED AT ALL LAP
POINTS AND CORNERS AND DEVELOPED AT NON-CONTINUOUS ENDS AS PER TYPICAL
DETAILS. SPLICE CONTINUOUS TOP BARS AT CENTER BETWEEN SUPPORTS AND SPLICE
CONTINUOUS BOTTOM BARS AT SUPPORTS.
8. CONCRETE COVER FOR REINFORCING BARS SHOWN IN TYPICAL DETAILS.
9. UNLESS NOTED, TEMPERATURE REINFORCING (ASTM A-615-60) TO BE 0.0018 X
CONCRETE AREA.
10. PROVIDE #4 @ 12" O.C., WITH STANDARD HOOK, TOP BARS IN ALL SLABS AT
DISCONTINUOUS ENDS UNLESS OTHERWISE NOTED ON PLANS. LENGTH OF BARS 1/4
OF SPAN, MINIMUM 3'-0". UNLESS OTHERWISE NOTED PROVIDE #4 @ 12" O.C IN ALL
CANTILEVERS. BAR LENGTH SHALL BE CANTILEVER SPAN PLUS 10'-0" PLUS STANDARD
HOOK AT CANTILEVER ENDS.
11. WHERE PIPE SLEEVES (UP TO 2" IN DIAMETER) PASS THROUGH CONCRETE BEAMS,
PROVIDE ADDITIONAL STIRRUP EACH SIDE OF SLEEVE, SLEEVES FOR PIPES 2" IN
DIAMETER OR LARGER MUST BE STEEL OR CAST IRON, AND THE LOCATION MUST BE
APPROVED BY THE STRUCTURAL ENGINEER.
12. ALL CONSTRUCTION JOINTS SHALL BE THOROUGHLY CLEANED JUST BEFORE PLACING
NEW CONCRETE IN ACCORDANCE WITH THE BUILDING CODE.
13. FOR CHAMFER OF EXPOSED CORNERS OF BEAMS AND/OR COLUMNS, SEE
ARCHITECTURAL DRAWINGS.
14. CONTRACTOR SHALL COORDINATE PLACEMENT OF, OR BOX OUT FOR, ALL PIPE
SLEEVES, OPENINGS, ETC, REQUIRED FOR VARIOUS TRADES.
15. CONTRACTOR SHALL COORDINATE AND NOTIFY OTHER TRADES IN SUFFICIENT TIME TO
ALLOW THEM TO SET ANCHORS, INSERTS, BOLTS, HANGERS, ETC., AS REQUIRED FOR
THEIR USE.
16. SEE ARCHITECTURAL DRAWINGS FOR DETAILS OF FLASHING REGLETS, FASCIA
DETAILS, ETC.
17. UNDER NO CIRCUMSTANCES SHALL CONCRETE BE PUMPED THROUGH ALUMINUM
PIPES. CONCRETE SHALL NOT BE PLACED IN CONTACT WITH ALUMINUM, ALUMINUM
MIXING DRUMS, TRUCK MIXERS, BUGGIES, CHUTES, CONVEYORS, TREMIE PIPES, AND
OTHER EQUIPMENT MADE OF ALUMINUM SHALL NOT BE USED ON THIS PROJECT.
18. SLUMPS OF OVER 4 INCHES WILL NOT BE PERMITTED UNLESS THE HRWR ADMIXTURE
(SUPER PLASTICIZER) IS USED. MAXIMUM SLUMP IS THEN 8 INCHES UNLESS
OTHERWISE DIRECTED BY THE ENGINEER.
19. NO ADMIXTURE SHALL BE USED IN CONCRETE EXCEPT WITH THE PERMISSION OF THE
ENGINEERS AND AFTER LABORATORY DESIGN MIX APPROVAL. ALL ADMIXTURES SHALL
CONTAIN NO MORE CHLORIDE IONS THAN ARE PRESENT IN MUNICIPAL DRINKING
WATER.
20. WATER REDUCING ADMIXTURE SHALL CONFORM TO THE ASTM C-494, TYPE A, AND
SHALL BE USED IN ALL CONCRETE.
21. AIR ENTRAINING ADMIXTURE SHALL CONFORM TO ASTM C260. AIR CONTENT OF
CONCRETE SHALL BE USED AS FOLLOWS:
A. FOR CONCRETE EXPOSED TO SOIL AND/OR WEATHER, 5%.
B. FOR INTERIOR WALLS, COLUMNS, AND SLABS, 3%.
22. FLY ASH - ASTMC618, TYPE C OR TYPE F SHOULD BE USED BUT NOT TO EXCEED 20%
CEMENTITIOUS CONTENT.
23. ALL EXPOSED CONCRETE SHALL RECEIVE A CURING COMPOUND. THE CURING
COMPOUND SHALL CONFORM TO ASTM C309 AND SHALL HAVE 30% SOLIDS MINIMUM.
WATER/BLANKET CURING AS PER ACI RECOMMENDATION MAY BE USED AS ALTERNATE.
24. UNLESS NOTED IN PROJECT SPECIFICATIONS, A TESTING LAB SHOULD PERFORM THE
FOLLOWING TEST:
• ATTENDANCE AT THE PROJECT SITE DURING ALL CONCRETE PLACING OPERATIONS
• CONTROL THE ADDITION OF MIXING WATER TO MAINTAIN THE REQUIRED
WATER/CEMENT RATIO AND INDICATED IN THE REPORT ANY ADDED WATER TO THE
MIX AND THE LOCATION OF PLACEMENT.
• ENSURE THAT THE CONCRETE IS OF THE PROPER TEMPERATURE WHEN PLACED.
• AIR CONTENT TESTS - AT LEAST TWO TESTS SHALL BE MADE FOR EACH DAY'S
PLACING OR FROM EACH BATCH OF CONCRETE FROM WHICH CYLINDERS ARE
CAST.
• SLUMP TESTS - AT FREQUENT INTERVALS TO PROPERLY CONTROL THE
CONSISTENCY AND AT LEAST ONE AT THE TIME OF CASTING EACH GROUP OF
CYLINDERS AND AT LEAST ONE TEST FOR EVERY 25 CUBIC YARDS.
• CONCRETE COMPRESSION CYLINDERS SHALL BE TAKEN FROM THE CONCRETE OF
EACH STRENGTH PLACED ON ANY ONE DAY AT LEAST ONE SET OF FIVE
REPRESENTATIVE 6" X 12" TEST CYLINDERS. FOR LARGE PLACEMENTS ON ANY ONE
DAY, THERE SHALL BE TAKEN NOT LESS THAN ONE SET OF FIVE REPRESENTATIVE
TYPE CYLINDERS FOR EACH 100 CUBIC YARDS OF CONCRETE OF EACH STRENGTH
PLACED. TWO CYLINDERS ARE TO BE TESTED AT 7 DAYS, TWO AT THE AGE OF 28
DAYS, AND THE FIFTH CYLINDER IN RESERVE FOR FURTHER TESTING. ASCERTAIN
THAT THE TEST SPECIMENS ARE PROPERLY PROTECTED UNTIL SHIPPED TO THE
TESTING LABORATORY. RECORD AND IDENTIFY EACH CYLINDER WITH THE
LOCATION OF THE CONCRETE FROM WHICH THE SPECIMEN WAS TAKEN. KEEP
MARKING IN SEQUENCE.
FOUNDATION NOTES:
1. SITE SOIL FOR THIS PROJECT HAS BEEN INVESTIGATED BY THE FIRM OF DRIGGERS
ENGINEERING SERVICES, INC. AND FOUND, AS PRESENTED IN THEIR REPORT DATED
JANUARY 31, 2025, SUITABLE TO SUPPORT UP TO 2.5 KSF SHALLOW FOUNDATIONS.
FOUNDATIONS HAVE BEEN DESIGNED IN ACCORDANCE WITH THE ABOVE STATED
CRITERIA.
2. FILL AND SUBGRADE PREPARATION SHALL BE IN ACCORDANCE WITH THE
GEOTECHNICAL ENGINEER RECOMMENDATION AS CONTAINED IN THEIR REPORT
STATED IN ITEM 1
3. ALL COLUMN FOOTINGS SHALL BE CENTERED UNDER COLUMN CENTERLINES
UNLESS OTHERWISE NOTED.
4. BACKFILLING AGAINST FOUNDATION WALLS SHALL BE DONE CAREFULLY WITH
SMALL COMPACTION EQUIPMENT, AFTER SLABS ON GROUND ARE IN PLACE AND
CONCRETE HAS SET. NO TRUCKS, BULLDOZERS, ETC. SHALL BE ALLOWED CLOSER
THAN 6'-0" TO ANY FOUNDATION WALL. ANY WALL 3'-0" OR HIGHER MUST BE BRACED
DURING THE CONSTRUCTION PROCESS.
5. NO FOUNDATIONS SHALL BE PLACED ABOVE 1 VERTICAL ON 2 HORIZONTAL SLOPES
EXTENDED FROM THE CLOSEST EDGE OF ANY UNDISTURBED SOIL OR OTHER
FOUNDATION STRUCTURE. BOTTOM OF FOOTINGS SHALL NOT BE LESS THAN
1'-0" BELOW EXISTING GRADE (U.N.O.).
6. FOR FOUNDATIONS SIZE AND REINFORCING SEE SCHEDULE.
7. ELEVATOR PIT DIMENSIONS = VERIFY WITH ELEVATOR MANUFACTURERS APPROVED
SHOP DRAWINGS.
8. WATER PROOFING MATERIALS SHALL BE PROVIDED ON ALL SIDES AND BOTTOM OF
ELEVATOR CORE.
9. TERMITE PROTECTION INCLUDING PIPING SLEEVES MUST FOLLOW THE
REQUIREMENTS OF SECTIONS 1816.1 AND 1816.2 OF THE FLORIDA BUILDING CODE,
7TH EDITION, 2020.
10. CONTRACTOR SHALL DETERMINE THE EXTENT OF CONSTRUCTION DEWATERING
REQUIRED FOR EXCAVATION AND COORDINATE WITH THE GEOTECHNICAL
ENGINEER PRIOR TO BEGINNING EXCAVATION.
MASONRY:
1. DESIGN AND CONSTRUCTION SHALL CONFORM TO BUILDING CODE
REQUIREMENTS FOR MASONRY STRUCTURES TMS 402-16.
2. MINIMUM NET COMPRESSIVE STRENGTH OF BLOCK ASSEMBLY SHALL BE
2000 P.S.I. (f'm) MORTAR FOR MASONRY SHALL BE TYPE "S" OR "M".
3. FOR ALL EXTERIOR AND INTERIOR BEARING, BED JOINTS ARE TO COVER 100% OF
THE MASONRY SURFACES AND ALL HEAD JOINTS ARE TO COVER 100% OF THE
PROJECTED AREA OF THE FACE SHELLS.
4. FILL ALL CELLS AS REQUIRED WITH 3000 P.S.I. GROUT. SLUMP SHALL BE 8 TO 11
INCHES. SUBMIT DESIGN MIX FOR APPROVAL.
5. MINIMUM HORIZONTAL JOINT REINFORCING SHALL BE 9 GAUGE HOT DIP
GALVANIZED TRUSS OR LADDER TYPE JOINT REINFORCING AT 16" O.C., PROVIDE
MANUFACTURE "T" AND "L" SHAPES FOR INTERSECTIONS AND CORNERS,
(MINIMUM LAP 6").
6. MINIMUM VERTICAL REINFORCING SHALL BE (1)-#5 @ 48" OR (1)-#4 @ 32" O.C.,
(U.N.O.).
7. PROVIDE ADDITIONAL VERTICAL REINFORCING BAR AT EVERY CORNER,
INTERSECTION, CONTROL JOINT, AND OPENING EDGES (U.N.O.).
8. MINIMUM SPLICE FOR VERTICAL REINFORCING IS SHOWN IN DETAIL 4-023, SPLICE
FOR HORIZONTAL JOINT REINFORCING = 6".
9. WALLS ARE DESIGNED TO BE BRACED BY FLOOR OR ROOF MEMBERS,
CONTRACTOR SHALL PROVIDE TEMPORARY BRACING DURING CONSTRUCTION.
10. ALL CELLS BELOW FIRST FLOOR FINISHED ELEVATION MUST BE FULLY GROUT
FILLED.
11. ALL KNOCK OUT BLOCK HORIZONTAL BARS SHALL HAVE CORNER BARS AT ALL
CORNERS AND WALL INTERSECTIONS. SIZE AND NUMBER OF CORNER BARS
SHALL BE SAME AS HORIZONTAL BARS.
12. ALL INTERSECTING WALLS AND CORNER WALLS SHALL BE LAID IN AN
OVERLAPPING MASONRY BONDING PATTERN, WITH ALTERNATE UNITS HAVING A
BEARING OF NOT LESS THAN 3 INCHES ON UNIT BELOW.
COMPOSITE METAL FLOOR DECK:
1. STEEL FLOOR DECK SHALL BE AS SPECIFIED IN THE FLOOR FRAMING NOTES ON
THE FLOOR PLAN.
2. ALL STEEL FLOOR DECK SHALL BE GALVANIZED G90.
3. ALL STEEL FLOOR DECK SHALL BE CAPABLE OF SUPPORTING ALL CONSTRUCTION
LOADS.
4. ALL STEEL FLOOR DECK SHALL BE CONTINUOUS OVER FOUR OR MORE
STRUCTURAL SUPPORTS (I.E. DECK SHOULD BE DETAILED FOR A THREE SPAN
CONDITION).
5. STEEL FLOOR DECK SHALL HAVE NESTING SIDE LAPS (ATTACHED BY MECHANICAL
MEANS) AT THE CENTER OF EACH SPAN OR 30" O/C, WHICHEVER IS LEAST
DIMENSION.
6. IF DECK IS CUT IN SINGLE SPAN CONDITION, EACH END OF SUCH SECTIONS SHALL
BE WELDED TO ITS SUPPORT THROUGH WELDING WASHERS IN THE BOTTOM OF
EACH RIB.
7. IN AREAS WHERE THE DECK IS CUT AS PER NOTE 6, THE GAUGE OF THE SINGLE
SPAN DECK SHALL BE ADJUSTED UPWARDS AS REQUIRED BY THE ENGINEER TO
SUPPORT THE LOADS.
8. ANY ELECTRICAL WORK WEIGHING MORE THAN 5 PSF OR 50 LBS SHALL BE HUNG
FROM STEEL BEAMS ONLY. FOR HANGERS, SEE SPECIFICATIONS. ALL MECHANICAL
WORK AND PIPING SHALL BE HUNG FROM STEEL BEAMS. SEE STRUCTURAL STEEL
NOTE 12 (OF STRUCTURAL STEEL NOTES) FOR ADDITIONAL STEEL REQUIRED BY
MECHANICAL/ELECTRICAL TRADES TO SUPPORT THEIR EQUIPMENT.
9. METAL DECK CONTRACTOR TO PROVIDE 18 GAUGE RIDGE PLATE, VALLEY PLATE,
EDGE STRIP, ETC., AS REQUIRED.
10. STEEL FLOOR DECK SHALL BE WELDED AT ENDS AND ALL INTERMEDIATE
SUPPORTING MEMBERS WITH 5/8" DIAMETER PUDDLE WELDS OR ELONGATED
WELDS OF EQUAL STRENGTH SPACED PER SPECIFICATIONS IN THE BOTTOM OF
THE RIB ACROSS THE WIDTH OF THE DECK UNIT.
11. CUT OUT METAL DECK WHERE BOLT PROJECTIONS INTERFERE WITH METAL DECK.
12. ANY SINGLE SPAN FLOOR DECK SHALL BE SHORED AT MIDSPAN DURING CONCRETE
PLACEMENT. SHORES SHALL REMAIN UNTIL CONCRETE HAS REACHED ITS 28-DAY
STRENGTH.
13. DIRECTION OF METAL DECK SHOWN THUS ON PLAN.
STEEL JOIST:
1. STEEL JOIST CONSTRUCTION SHALL CONFORM TO THE LATEST SPECIFICATIONS
OF, AND THE JOISTS SHALL BE APPROVED BY, THE STEEL JOIST INSTITUTE.
2. UNLESS OTHERWISE NOTED, BEAR SHORT SPAN JOISTS MINIMUM OF 2-1/2" ON
STEEL BEAMS AND BEAR LONG SPAN JOIST MINIMUM OF 4" ON STEEL SUPPORTS.
IN CASES WHERE JOISTS BEAR ON BEAMS FROM ONE SIDE ONLY, JOIST SEATS
SHALL EXTEND A MINIMUM OF 1" PAST THE CENTERLINE OF SUPPORTING BEAM.
3. ALL JOISTS BEARING ON BEAMS SHALL BE WELDED OR BOLTED TO THOSE BEAMS.
4. PROVIDE BRIDGING FOR ALL JOISTS AS SHOWN ON PLAN BUT NOT LESS THAN
WHAT IS REQUIRED BY THE STEEL JOIST INSTITUTE OR THE STEEL JOIST DESIGNER.
BRIDGING SHALL CONSIST OF MINIMUM 1-1/4" X 1-1/4" X 7/64" ANGLES, (U.N.O.).
5. ALL BRIDGING SHALL BE PROVIDED AND INSTALLED BY JOIST SUPPLIER.
6. ALL CLIPS AND CONNECTIONS SHALL BE SHOP WELDED.
7. NO FIELD WELDING TO BAR JOISTS EXCEPT ITEMS SPECIFICALLY SHOWN ON
STRUCTURAL DRAWINGS SHALL BE ALLOWED WITHOUT SPECIFIC PERMISSION
FROM THE ENGINEER.
8. NO JOIST SHALL BE FIELD SPLICED.
9. MAXIMUM DEFLECTION OF STEEL JOISTS = L/360 FOR LIVE LOAD.
10. FOR PAINTING OF STEEL JOIST, SEE SPECIFICATIONS.
11. JOIST MANUFACTURER SHALL SUBMIT WITH THE SHOP DRAWINGS HIS CATALOG
USED FOR THE MANUFACTURE OF JOISTS, INDICATING THE LOAD TABLES AND
SIZES OF ALL MEMBERS USED.
12. NO LOADS EXCEEDING 40 POUNDS MAY BE HUNG FROM JOISTS WITHOUT SPECIFIC
PERMISSION FROM THE STRUCTURAL ENGINEER. LOADS LESS THAN 40 POUNDS
MAY BE HUNG AT PANEL POINTS ONLY. ANY COST INVOLVED IN REINFORCING OF
JOISTS SHALL BE BORNE BY THE PRIME CONTRACTOR REQUIRING ADDED LOADS.
13. ALL SHORT SPAN JOISTS, AND DEEP LONG SPAN JOISTS SHALL HAVE UNIFORM
CROSS SECTION, WITH STANDARD DEAD LOAD CAMBER. ROOF PITCH IS
ACCOMPLISHED BY SLOPED JOISTS AND SUPPORT BEAMS. ADJUST JOIST SEATS AS
SHOWN ON DRAWINGS.
14. FOR SPECIFIC JOIST ENDS, SEE ROOF SECTIONS.
15. RIGID CONNECTIONS OF BOTTOM CHORDS OF JOISTS TO COLUMNS SHALL BE MADE
ONLY AFTER THE APPLICATION OF ALL THE DEAD LOADS. PROVIDE LOOSE BOLTED
CONNECTION OF THESE BOTTOM CHORDS DURING ERECTION.
16. JOIST SHALL NOT BE FABRICATED USING ELECTRICAL RESISTANCE WELDING.
17. LONG SPAN ROOF JOISTS AT THE GYMNASIUM SUPPORTING THE SUSPENDED
TRACK SHALL BE DESIGNED FOR VIBRATION IN ACCORDANCE WITH THE AISC
DESIGN GUIDE 11: FLOOR VIBRATION DUE TO HUMAN ACTIVITY.
STEEL ROOF DECK:
1. STEEL ROOF DECK SHALL BE A MINIMUM OF 1-1/2" - 20 GAUGE WIDE RIB FOR SPANS UP
TO 6'-0" OR 3" TYPE N - 20 GAUGE FOR SPANS UP TO 12'-0" . THE SIZE, TYPE AND GAUGE
INDICATED ABOVE SHOULD BE USED UNLESS A DIFFERENT ONE IS INDICATED IN THE
ROOF FRAMING NOTES OF THE ROOF PLAN DRAWING.
2. ALL STEEL ROOF DECK SHALL BE GALVANIZED G90 AS PER ASTM SPECIFICATIONS. ALL
ROOF DECK SHOULD BE VENTED WHEN A LIGHT WEIGHT INSULATING CONCRETE IS
USED FOR ROOFING.
3. ALL STEEL ROOF DECK SHALL BE CAPABLE OF SUPPORTING ALL CONSTRUCTION
LOADS.
4. ALL STEEL ROOF DECK SHALL BE CONTINUOUS OVER FOUR OR MORE STRUCTURAL
SUPPORTS (I.E. DECK SHOULD BE DETAILED FOR A THREE SPAN CONDITION.)
5. STEEL ROOF DECK SHALL HAVE NESTING SIDE LAPS (ATTACHED BY MECHANICAL
MEANS). PROVIDE FASTENER LAYOUT AS PER TYPICAL DETAIL 5-305.
6. IF DECK IS CUT IN SINGLE SPAN CONDITION, EACH END OF SUCH SECTIONS SHALL BE
WELDED TO ITS SUPPORT THROUGH WELDING WASHERS IN THE BOTTOM OF EACH RIB.
7. IN AREAS WHERE THE DECK IS CUT AS PER NOTE 6, THE GAUGE OF THE SINGLE SPAN
DECK SHALL BE ADJUSTED UPWARDS AS REQUIRED BY THE ENGINEER TO SUPPORT
THE LOADS.
8. ANY ELECTRICAL WORK WEIGHING MORE THAN 5 PSF OR 50 LBS CONCENTRATED
SHALL BE HUNG FROM STEEL BEAMS/JOISTS ONLY. FOR HANGERS, SEE
SPECIFICATIONS. ALL MECHANICAL WORK AND PIPING SHALL BE HUNG FROM STEEL
BEAMS/JOISTS.
9. METAL DECK CONTRACTOR TO PROVIDE 18 GAUGE RIDGE PLATE, VALLEY PLATE, EDGE
STRIP, ETC., AS REQUIRED.
10. STEEL ROOF DECK SHALL BE WELDED AT ENDS AND ALL INTERMEDIATE SUPPORTING
MEMBERS WITH 5/8" DIAMETER PUDDLE WELDS OR ELONGATED WELDS OF EQUAL
STRENGTH SPACED PER SPECIFICATIONS IN THE BOTTOM OF THE RIB ACROSS THE
WIDTH OF THE DECK UNIT.
11. CUT OUT METAL DECK WHERE BOLT PROJECTIONS INTERFERE WITH METAL DECK.
12. DIRECTION OF METAL DECK SHOWN THUS ON PLAN.
LIGHTGAUGE METAL FRAMING:
1. ALL STRUCTURAL MEMBERS SHALL BE DESIGNED IN ACCORDANCE WITH AMERICAN
IRON AND STEEL INSTITUTE, "SPECIFICATION FOR THE DESIGN OF COLD FORMED
STRUCTURAL MEMBERS", 2016 EDITION. PROVIDE SIGN AND SEALED CALCULATIONS AND
DRAWINGS FOR ALL LIGHT GAUGE STRUCTURAL ELEMENTS OF THE BUILDING,
INCLUDING THE EXTERIOR METAL STUDS (CURTAIN WALL), AND ALL EXTERIOR CEILINGS.
2. ALL STRUCTURAL STUDS AND JOISTS 22, 20, AND 18 GAUGES SHALL BE FORMED FROM
GALVANIZED STEEL PER ASTM A653, G60 COATING MEETING THE REQUIREMENTS OF
ASTM C955 WITH A YIELD STRENGTH OF 33,000 PSI.
3. ALL STRUCTURAL STUDS AND JOISTS 16, 14, AND 12 GAUGES SHALL BE FORMED FROM
GALVANIZED STEEL PER ASTM A653, G60 COATING MEETING ASTM C955, WITH YIELD
STRENGTH OF 50,000 PSI.
4. ALL STRUCTURAL TRACK AND BRIDGING SHALL BE FORMED FROM GALVANIZED STEEL
PER ASTM A653, G60 COATING MEETING THE REQUIREMENTS OF ASTM C595, WITH
YIELD STRENGTH OF 33,000 PSI.
5. WITH EACH TYPE OF METAL FRAMING REQUIRED, PROVIDE MANUFACTURER'S
STANDARD STEEL RUNNERS (TRACKS), BLOCKING, LINTELS, CLIP ANGELS, SHOES,
REINFORCEMENTS, FASTENERS, AND ACCESSORIES AS RECOMMENDED BY
MANUFACTURER FOR APPLICATIONS INDICATED, AS NEEDED TO PROVIDE A COMPLETE
METAL FRAMING SYSTEM.
6. PROVIDE GALVANIZED FINISH TO METAL FRAMING COMPONENTS COMPLYING WITH
ASTM A653 FOR MINIMUM G60 COATING. ATTACH SIMILAR COMPONENTS BY WELDING.
ATTACH DISSIMILAR COMPONENTS BY WELDING, BOLTING OR SCREW FASTENERS, AS
STANDARD WITH MANUFACTURER. ALL WELDING SHALL BE PERFORMED BY WELDERS
CERTIFIED AND EXPERIENCED IN LIGHT GAUGE STRUCTURAL STEEL FRAMING WORK.
7. INSTALL METAL FRAMING SYSTEMS IN ACCORDANCE WITH MANUFACTURER'S PRINTED
OR WRITTEN INSTRUCTIONS AND RECOMMENDATIONS, UNLESS OTHERWISE INDICATED.
8. INSTALL CONTINUOUS TRACKS SIZED TO MATCH STUDS.
9. SET STUDS PLUMB, EXCEPT AS NEEDED FOR DIAGONAL BRACING OR REQUIRED FOR
NON-PLUMB WALLS OR WARPED SURFACED AND SIMILAR REQUIREMENTS.
10. WHERE STUD SYSTEM ABUTS STRUCTURAL COLUMN OR WALLS, INCLUDING MASONRY
WALL, ANCHOR ENDS OF STIFFENERS TO SUPPORTING STRUCTURE.
11. SECURE STUDS TO TOP AND BOTTOM RUNNER TRACKS BY EITHER WELDING OR SCREW
FASTENERS AT BOTH INSIDE AND OUTSIDE FLANGES.
SHOP DRAWINGS:
1. NO STRUCTURAL DRAWINGS SHALL BE REPRODUCED FOR USE AS SHOP
DRAWINGS.
2. ALL DIMENSIONAL COORDINATION SHALL BE DONE BY THE CONTRACTOR
AND/OR HIS DETAILER.
3. DETAILER SHALL CHECK ALL ARCHITECTURAL AND MECHANICAL DRAWINGS
FOR ALL ATTACHMENTS, CLIPS, OPENINGS, OR DUCT WORK AFFECTING
STRUCTURAL MEMBERS. ALL ITEMS SHALL BE SHOWN ON SHOP DRAWINGS.
4. ALL SHOP DRAWINGS SHALL BE SUBMITTED ELECTRONICALLY IN PDF
FORMAT. DISTRIBUTION AS PER ARCHITECT INSTRUCTIONS.
5. PROVIDE SUFFICIENT SPACE ON SHOP DRAWINGS NEAR TITLE BOX (ABOUT 40
SQUARE INCHES) FOR STAMPS AND ENGINEERS COMMENTS.
6. THE SHOP DRAWINGS SHALL BEAR INITIALS OF DETAILER'S CHECKER AND
CONTRACTOR PRIOR TO SUBMISSION.
7. COMPLETED ERECTION PLANS SHALL BE SUBMITTED PRIOR TO OR IN
CONJUNCTION WITH DETAIL DRAWINGS. BUT IN NO CASE SHALL DETAIL
DRAWINGS BE SUBMITTED PRIOR TO ERECTION PLANS.
8. DETAILER SHALL SUBMIT AN INDEX OF THE DETAIL DRAWINGS WITH EACH
SHOP DRAWING SUBMITTAL.
9. SHOP DRAWINGS NOT COMPLYING WITH ALL THE ABOVE ITEMS SHALL BE
RETURNED FOR CORRECTIONS WITHOUT PROCESSING.
10. RESUBMITTED SHOP DRAWINGS SHALL HAVE THE FOLLOWING CHANGES
INCORPORATED: FIRST RESUBMISSION TO HAVE LETTER "A" ADDED TO
DRAWING
A. NUMBER AND ANY CHANGES MARKED ON THE DRAWING MARKED 1 AT
EACH ITEM CHANGED. ALL ITEMS TO BE NOTED IN REVISION BOX.
B. SUBSEQUENT RESUBMISSION SHALL BEAR CHANGES "B" AND 2 AND 3
ETC. AS IN 11A.
11. CONTRACTOR SHALL HAVE SHOP DRAWINGS WHICH HAVE BEEN
SATISFACTORILY REVIEWED BY THE ARCHITECT AND/OR ENGINEER AND
CONFIRMED BY THE CONTRACTOR BEFORE PROCEEDING WITH ANY WORK.
12. DETAILER SHALL USE THE SAME STRUCTURAL ELEMENTS NUMBERS IN HIS
DETAILS AS THOSE SHOWN ON CONTRACT DRAWINGS.
13. SHOP DRAWINGS FOR ALL STRUCTURAL ELEMENTS SHOULD BE SUBMITTED
TO MCE WITH A MINIMUM TIME TO BE REVIEWED OF 10 WORKING DAYS. IN
CASE OF A LARGE SUBMITTAL OR MORE THAN ONE SUBMITTAL FOR THE
SAME PROJECT, AN ADDITIONAL WORKING DAY IS REQUIRED FOR EVERY 5
DRAWINGS/SHEETS OVER 30 DRAWINGS/SHEETS. THE TIME INDICATED ABOVE
IS FOR MCE REVIEW ONLY, CONTRACTOR MUST INCLUDE ENOUGH TIME FOR
DELIVERY, ARCHITECTURAL REVIEW, AND OWNERS REVIEW AND WORK THIS
TIME IN THE PROJECT SCHEDULE AS NEEDED.
14. THERE SHALL BE NO DEVIATION FROM THESE CONSTRUCTION DOCUMENTS.
IF ANY CHANGES ARE PROPOSED BY THE CONTRACTOR OR THE PROVIDER
OF THE SHOP DRAWINGS, THEY SHOULD BE CLEARLY INDICATED, SIGNED
AND SEALED DRAWINGS AND CALCULATIONS BY A FLORIDA PROFESSIONAL
ENGINEER MUST BE PROVIDED. ANY CHANGES WITHOUT PROPER
DOCUMENTATION INDICATED ABOVE WILL RESULT IN SOME REVISIONS BY
THE ENGINEER OF RECORD AND/OR ARCHITECT. THE COST FOR THESE
REVISIONS INCLUDING ENGINEER AND ARCHITECTURAL FEES SHALL BE PAID
BY THE CONTRACTOR.
STRUCTURAL STEEL:
1. ALL STRUCTURAL STEEL WORK SHALL BE FABRICATED AND ERECTED IN
ACCORDANCE WITH THE LATEST A.I.S.C. SPECIFICATIONS.
2. STRUCTURAL STEEL SHALL CONFORM TO:
WIDE FLANGE (WF) ASTM A992 (50 KSI)
SHAPES (L,T,C,PL) ASTM A36
EMBED PLATES ASTM A572 (50 KSI)
STRUCTURAL TUBE (HSS) ASTM A500 (46 KSI)
STEEL PIPE (HSS) ASTM A500 (42 KSI)
ANCHOR BOLTS ASTM F1554 (36 KSI) U.N.O.
IN PLANS, OR SECTIONS.
FRAMING BOLTS ASTM A325 OR A490
SHEAR STUDS ASTM A108
WELDING ELECTRODES E70XX
3. ALL HIGH STRENGTH BOLTS SHALL CONFORM TO ASTM SPECIFICATION A325 AND
SHALL BE PROVIDED WITH HARDENED WASHERS UNDER THE TURNED ELEMENT
(NUT OR BOLT HEAD).
4. INSTALLATION AND TIGHTENING OF ALL HIGH STRENGTH BOLTS SHALL CONFORM TO
THE "SPECIFICATION FOR STRUCTURAL JOINTS USING ASTM A325 OR A490 BOLTS".
5. SHOP CONNECTIONS MAY BE WELDED OR HIGH STRENGTH BOLTED. ALL BOLTS
SHALL BE 3/4" DIAMETER MINIMUM. ALL CONNECTIONS SHALL CONFORM TO THE
TYPICAL CONNECTION DETAILS SHOWN ON THE PLANS UNLESS SPECIFICALLY
APPROVED BY THE ENGINEER.
6. ALL FIELD CONNECTIONS SHALL BE BOLTED WITH HIGH STRENGTH BOLTS, SLIP-
CRITICAL (FRICTION) TYPE EXCEPT WHERE SLOTTED HOLES ARE SPECIFIED OR
WHERE MOVEMENT OF THE CONNECTED MEMBERS IS EXPECTED. IN THESE CASES
PROVIDE OVERSIZED WASHER, HAND TIGHTEN BOLTS, AND TACK WELD WASHER TO
NUT TO VERIFY ASSEMBLY IS HELD TOGETHER.
7. ALL WELDING SHALL CONFORM TO THE AMERICAN WELDING SOCIETY CODE, ANS01.1,
ALL WELDING SHALL BE PERFORMED USING E7OXX U.N.O.
8. CUTS, HOLES, COPINGS, ETC. REQUIRED IN STRUCTURAL STEEL MEMBERS FOR THE
WORK OF OTHER TRADES SHALL BE SHOWN IN THE STRUCTURAL STEEL SHOP
DRAWINGS AND SHALL BE MADE IN THE SHOP. HOLES SHALL BE REINFORCED AS
REQUIRED BY THE ENGINEER.
9. BURNING OF HOLES, CUTS, ETC. IN STRUCTURAL STEEL MEMBERS IN THE FIELD WILL
NOT BE PERMITTED, EXCEPT WITH THE SPECIFIC APPROVAL OF THE ENGINEER.
10. ALL STEEL MEMBERS (SUCH AS BEAMS, COLUMNS, PLATES, BOLTS, LINTELS, DOOR
JAMBS, ETC.) EXPOSED TO WEATHER AND ALL MEMBERS IN AN EXTERIOR ENCLOSED
NON-AIR-CONDITIONED AREA, SHALL BE HOT DIPPED GALVANIZED.
11. FOR MISCELLANEOUS STEEL, SEE ARCHITECTURAL DRAWINGS.
12. ANY STEEL MEMBERS REQUIRED BY THE ELECTRICAL OR MECHANICAL TRADES FOR
THE SUPPORT OF THEIR EQUIPMENT, WHICH ARE NOT SHOWN ON ARCHITECTURAL
OR STRUCTURAL DRAWINGS, SHALL BE PROVIDED BY THE TRADE REQUIRING SUCH
SUPPORT.
13. SEE SPECIFICATIONS FOR PAINTING OF STRUCTURAL STEEL. ALL FABRICATION AND
ERECTION MARKS SHALL BE COVERED DURING FIELD TOUCH-UP PAINTING.
14. ALL CONNECTIONS TO BE DOUBLE ANGLE FRAMED BEAM CONNECTION PER AISC
UNLESS NOTED OTHERWISE. ALL BOLTS TO BE 3/4" MINIMUM DIAMETER UNLESS
NOTED OTHERWISE. SHOP CONNECTIONS MAY BE WELDED OR BOLTED. WELDS ARE
TO BE EQUAL IN STRENGTH TO BOLTS.
15. DESIGN CONNECTIONS FOR HALF THE MAXIMUM SHEAR (V IN KIPS) LISTED IN THE
TABLE 3-6 "MAXIMUM TOTAL UNIFORM LOAD" AT THE BOTTOM OF EACH PAGE IN THE
"BEAM PROPERTIES" OF THE AISC 360-16" MANUAL OF STEEL CONSTRUCTION.
"MINIMUM CONNECTION SHALL CONSIST OF TWO 3/4"Ø A325 BOLTS. REACTIONS
SHOWN ARE BASED ON UNFACTORED LOADS. PROVIDE SIGNED AND SEALED
DRAWINGS AND CALCULATIONS BY A PROFESSIONAL ENGINEER.
16. DESIGN BASE PLATE ANCHOR BOLTS FOR LATERAL MEMBERS USING FORCES
INDICATED IN DRAWINGS. PROVIDE SIGNED AND SEALED DRAWINGS AND
CALCULATIONS BY A PROFESSIONAL ENGINEER.
17. WHEN STEEL MEMBERS ARE WELDED TO EMBED PLATES IN CONCRETE, WELDING
PROCESS SHOULD BE PERFORMED IN SUCH WAY THAT EMBED PLATE DOES NOT
OVERHEAT AND EXPAND. SUCH EXPANSION WILL CRACK THE CONCRETE
SURROUNDING THE EMBED PLATE AND MAY WEAKEN THE STRUCTURAL CAPACITY
OF THE CONNECTION. WE RECOMMEND TO PROVIDE SEVERAL SINGLE PASSES TO
BUILT UP THE WELD SIZE REQUIRE WITH COOLING OFF PERIODS TO AVOID THE
EMBED PLATE EXPANSION. UNDER NO CIRCUMSTANCES PROVIDE MORE THAN 6" OF
1/4" WELD WITHOUT ALLOWING A COOLING OFF PERIOD.
18. EXPOSED ENDS OF STRUCTURAL TUBES OR PIPES SHALL BE CAPPED WITH A
MINIMUM 1/4" PLATE U.N.O.
19. ALL WELDS SHALL BE VISUALLY INSPECTED AND COMPLIANT WITH AWS D1.1
ACCEPTANCE CRITERIA. ALL COMPLETE JOINT PENETRATION WELDS SHALL BE
TESTED FOR THEIR FULL LENGTH BY MEANS OF AN APPROVED NONDESTRUCTIVE
TEST IN ACCORDANCE WITH AWS D1.1.
POST-INSTALLED ANCHORS
1. POST-INSTALLED ANCHORS SHALL ONLY BE USED WHERE SPECIFIED ON THE
CONSTRUCTION DOCUMENTS. SPECIAL INSPECTIONS ARE REQUIRED PER
THE PROVISIONS SET FORTH BELOW. CONTRACTOR TO CONTACT
MANUFACTURER'S REPRESENTATIVE FOR PROPER PRODUCT INSTALLATION
TRAINING ON INITIAL ANCHORS.
2. SUBSTITUTION REQUESTS, FOR PRODUCTS OTHER THAN THOSE SPECIFIED
BELOW, SHALL BE SUBMITTED BY THE CONTRACTOR TO THE ENGINEER-OF-
RECORD ALONG WITH CALCULATIONS THAT ARE PREPARED & SEALED BY A
REGISTERED PROFESSIONAL ENGINEER. THE CALCULATIONS SHALL
DEMONSTRATE THAT THE SUBSTITUTED PRODUCT IS CAPABLE OF ACHIEVING
THE PERTINENT EQUIVALENT PERFORMANCE VALUES (MINIMUM) OF THE
SPECIFIED PRODUCT USING THE APPROPRIATE DESIGN PROCEDURE AND/OR
STANDARD(S) AS REQUIRED BY THE BUILDING CODE.
3. EXPANSION ANCHORS SHALL BE STUD TYPE WITH A SINGLE PIECE OF THREE
SECTION WEDGE AND ZINC PLATED IN ACCORDANCE WITH ASTM B633. THE
ANCHORS SHALL MEET FEDERAL SPECIFCATION FF-S-325, GROUP II, TYPE 4,
CLASS I FOR CONCRETE EXPANSION ANCHORS. ANCHORS SHALL BE HILTI
KWIK BOLT 3 AS SUPPLIED BY HILTI INC. TULSA OKLAHOMA. ANCHORS SHALL
BE INSTALLED IN HOLES DRILLED WITH HILTI CARBIDE TIPPED DRILL BITS OR
MATCHED TOLERANCE DIAMOND CORE BITS. ANCHORS SHALL BE INSTALLED
IN ACCORDANCE WITH MANUFACTURE'S RECOMMENDATIONS.
4. INJECTED ADHESIVE ANCHORS SHALL BE USED FOR INSTALLATION OF
THREADED RODS. ADHESIVE SHALL BE FURNISHED IN A SIDE BY SIDE REFILL
PACK WHICH KEEP COMPONENT A AND B SEPARATE. INJECTION ADHESIVE
SHALL BE HILTI HIT HY 200 AS SUPPLIED BY HILTI INC. TULSA OKLAHOMA.
ANCHOR RODS MEET ASTM F1554 (36 KSI). NUTS AND WASHERS SHALL BE
FURNISHED TO MEET THE REQUIREMENTS OF AN ASTM F1554 (36 KSI) STEEL
ROD.
5. POST-INSTALLED ANCHOR LOCATIONS, MINIMUM EDGE/END DISTANCES AND
MINIMUM CAPACITIES SHALL MEET THE MANUFACTURER'S SPECIFICATIONS.
DELEGATED DESIGN
1. SELECT SCOPE ITEMS IN THE PROJECT ARE CUSTOM DESIGNED AND
ENGINEERED. THE ENGINEERING RESPONSIBILITY IS DELEGATED TO THE
CONTRACTOR AND RELATED SUBCONTRACTORS.
2. CONTRACTOR SHALL SUBMIT SIGNED AND SEALED SHOP DRAWINGS AND
CALCULATIONS FOR SUCH ELEMENTS DESIGNATED TO BE DESIGNED BY A
DELEGATED ENGINEER.
3. DELEGATED ENGINEERING WILL ADDRESS ALL LOADING REQUIREMENTS
INCLUDING WIND PRESSURES IN ACCORDANCE WITH THE LATEST FLORIDA
BUILDING CODE. REFER TO THE COMPONENTS AND CLADDING PRESSURES
PROVIDED FOR DESIGN PRESSURES ELEMENTS SHALL BE IN CONFORMANCE
WITH.
4. DELEGATED ENGINEERED DRAWINGS SHALL DEFINE MATERIAL THICKNESS,
SIZING, CONNECTIONS, ETC. OF THE SUBMITTED SYSTEM.
5. DELEGATED ENGINEERED DRAWINGS AND CALCULATIONS WILL BE
REVIEWED AS PART OF THE SUBMITTAL PROCESS.
6. BUILDING COMPONENTS THAT ARE NOT SPECIFIED AS DELEGATED TO
OTHER ENGINEERS SHALL BE SUBMITTED WITH APPROPRIATE FLORIDA
PRODUCT APPROVAL INFORMATION IN THE SUBMITTAL. WHERE A FLORIDA
PRODUCT APPROVAL DOES NOT EXIST FOR A COMPONENT REQUIRING
APPROVAL, THE DESIGN SHALL BE DELEGATED TO AN ENGINEER ON THE
CONTRACTOR'S TEAM.
7. DELEGATED ENGINEERING AND DEFERRED SUBMITTALS:
A. DEFERRED SUBMITTALS SHALL HAVE THE SHOP DRAWINGS AND
DELEGATED DESIGN SUBMITTALS (INCLUDING CALCULATIONS) SIGNED
AND SEALED BY A PROFESSIONAL ENGINEER REGISTERED IN THE STATE
OF FLORIDA.
B. DOCUMENTS FOR DEFERRED SUBMITTAL ITEMS SHALL BE SUBMITTED TO
THE REGISTERED DESIGN PROFESSIONAL FOR REVIEW AND SHALL BE
FORWARDED TO THE BUILDING OFFICIAL.
C. DEFERRED SUBMITTAL ITEMS SHALL NOT BE INSTALLED UNTIL THE
DEFERRED SUBMITTAL DOCUMENTS HAVE BEEN APPROVED BY THE
BUILDING OFFICIAL.
D. THE FOLLOWING ITEMS ARE CONSIDERED DEFERRED SUBMITTALS BY
THE REGISTERED DESIGN PROFESSIONAL:
a. EXTERIOR OR LOAD BEARING COLD FORMED METAL FRAMING
b. EXTERIOR CURTAIN WALL SYSTEM
c. EXTERIOR AWNINGS, SUNSHADES, EYEBROWS AND CANOPIES
d. ARCHITECTURAL PRECAST CONCRETE
e. METAL FABRICATIONS, RAILINGS, LADDERS AND GRATINGS
f. STEEL STAIRS
g. MECHANICAL PIPING SUPPORTS
h. STRUCTURAL STEEL CONNECTIONS
i. STEEL BAR JOISTS
j. METAL DECKING
k. ROOF TOP EQUIPMENT AND ANCHORAGES
l. WINDOW WASHING AND FALL ARREST SYSTEMS
DEMOLITION NOTES:
1. PROVIDE AND MAINTAIN SHORING, BRACING OR STRUCTURAL SUPPORT TO
PRESERVE STABILITY AND PREVENT MOVEMENT, SETTLEMENT, OR COLLAPSE
OF CONSTRUCTION TO REMAIN, AND TO PREVENT UNEXPECTED OR
UNCONTROLLED MOVEMENT OR COLLAPSE OF CONSTRUCTION BEING
DEMOLISHED.
2. PROCEED WITH SELECTIVE DEMOLITION SYSTEMATICALLY, FROM HIGHER TO
LOWER LEVEL. COMPLETE SELECTIVE DEMOLITION OPERATIONS ABOVE EACH
FLOOR OR TIER BEFORE DISTURBING SUPPORTING MEMBERS ON THE NEXT
LOWER LEVEL.
3. NEATLY CUT OPENINGS AND HOLES PLUMB, SQUARE AND TRUE TO
DIMENSIONS REQUIRED. USE CUTTING METHODS LEAST LIKELY TO DAMAGE
CONSTRUCTION TO REMAIN OR ADJOINING CONSTRUCTION. USE HAND TOOLS
OR SMALL POWER TOOLS DESIGNED FOR SAWING OR GRINDING, NOT
HAMMERING OR CHOPPING, TO MINIMIZE DISTURBANCE OF ADJACENT
SURFACES. TEMPORARILY COVER OPENINGS TO REMAIN.
4. REMOVE STRUCTURAL FRAMING AND LOWER STRUCTURAL MEMBERS TO
GROUND BY METHOD SUITABLE TO AVOID FREE FALL AND TO PREVENT
GROUND IMPACT OR DUST GENERATION.
5. LOCATE SELECTIVE DEMOLITION EQUIPMENT AND REMOVE DEBRIS AND
MATERIALS SO AS NOT TO IMPOSE EXCESSIVE LOADS ON SUPPORTING
WALLS, FLOORS, OR FRAMING.
6. NEW OPENINGS NOT SHOWN ON STRUCTURAL DRAWINGS ARE NOT
PERMITTED.
TH
IS
D R
AW
IN
G A
N D
A
LL
IN
FO
R M
AT
IO
N C
O N
TA
IN
ED
H
ER
EI
N
IS
TH
E
SO
LE
P R
O
PE
R
TY
O F
M
AS
TE
R
C O
N
SU
LT
IN
G E
N G
IN
EE
R S, IN
C
. A N
D M
AY
N
O T
BE
R
EP
R
O D
U C
ED
, C
O
PI
ED
, A
LT
ER
ED
O
U
SE
D
IN
A N
Y W
AY
W
IT
H
O U
T
TH
E
EX
PR
ES
S W
R
IT
TE
AU
O R
IZ
AT
IO
N
F R
O M
M
AS
TE
R
C O
N
SU
LT
IN
G E
N G
IN
EE
R S, IN
C
W E
S T
C Y
P R
E S
S S
T
S T
E .2
T
A M
P A
, F
LO
R
ID
A
-1
P
3.
7.
F
3.
7.
C A
TO THE BEST OF OUR KNOWLEDGE, INFORMATION
AND BELIEF, THESE STRUCTURAL PLANS CONFORM
TO AND SATISFY, THE FLORIDA BUILDING CODE,
EIGHTH EDITION 2023, ACI 318-19 AND LOCAL CODES
AS APPLICABLE
S T
E V
IE
W
L O
C K
H A
R T
P
.E
F L L
IC
N o
T H
E A
R C
H
IT
E C
T 'S
C O
M M
O N
L A
W C
O P
Y R
IG
H
T A
D
T
H E
R P
R O
P E
R T
Y R
IG
H
T S
A R
E H
E R
E B
Y R
E S
E R
V
H E
I D
E A
S
D E
S
IG
N S
P L A
N S
D
R A
W
IN
G S
A
S P
E C
IF
IC
A T
IO
N
S P
R O
D U
C E
D B
Y T
H E
A R
C H
IT
E
C T
T H
E S E
I D
E A
S
D E
S
IG
N S
P
L A
N S
D
R A
W
IN
G S
A
E C
IF
IC
A T
IO
N
S S
H A
LL
N
O T
B E
R E
P R
O D
U C
E D
N V
E Y
E D
I N
A N
Y M
A N
N E
R N
O R
A S
S
IG
N E
D
A
Y T
H
IR
D P
A R
T Y
W
IT
H O
U T
F
IR
S T
O B
T A
IN
IN
G T
H
X
P R
E S
S W
R
IT
T E
N P
E R
M
IS
S
IO
N O
F T
C H
IT
E
C T
C
O N
S E
N T
I S
H E
R E
B Y
G R
A N
T E
D
G
V E
R N
M E
N T
A L
A G
E N
C
IE
S T
O R
E P
R O
D U
C E
T
N S T
R U
C T
IO
N
D R
A W
IN
G
S I
N C
O M
P
LI
A N
C E
W
IT
E S
T A
T E
S T
A T
U T
E S
T
O T
H E
B E
S T
O F
T
C H
IT
E
C T
'S O
F E
N G
IN
E
E R
'S K
N O
W
LE
D G
E
T
LA
N S A
N D
S P
E C
IF
IC
A T
IO
N
S C
O M
P
LY
W
IT
H T
P
LI
C A
B L E
M
IN
IM
U
M B
U
IL
D
IN
G C
O D
E S
A N
D T
P
LI
C A
B L E
F
IR
E S
A F E
T Y
S T
A N
D A
R D
S
T E
R M
IN
E
D B
Y T
H E
L O
C A
L A
U T
H O
R
IT
Y I
C O
R D
A N
C E
W
IT
H C
H A
P T
E R
S
A N
D
E F
L O
R
ID
A S
T A
T U
T E
S
W J
A rc hi te ct s
A R
(7
2-w w .w ja rc
.c om
W an ne m ac he r
Je ns en A rc hi te ct s, In c.
Project number
P R
O J
N O
-1
-1
S-101
GENERAL
STRUCTURAL NOTES
P A
L M
H A
R B
O R
P A
R K
S A
N D
R E
C R
E A
T
IO
N
P
IN
E
LL
A S
C O
U N
T Y
6T
H S
T R
E E
T , P
A
LM
H A
R B
O R
F L
N E
W R
E C
R E
A T
IO
N
C E
N T
E R
PERMIT SET 9-15-25
STRUCTURAL SHEET INDEX
SHEET NUMBER SHEET NAME
S-101 GENERAL STRUCTURAL NOTES
S-102 WIND DESIGN DATA AND LOAD SCHEDULE
S-103 THRESHOLD INSPECTION PLAN
S-104 ISOMETRIC VIEWS
S-201 FOUNDATION PLAN
S-202 SLAB ON GRADE PLAN
S-203 2ND FLOOR FRAMING PLAN
S-204 ROOF FRAMING PLAN
S-205 ENLARGED PLANS & DETAILS
S-301 TYPICAL DETAILS - CONCRETE
S-302 TYPICAL DETAILS - CONCRETE
S-303 TYPICAL DETAILS - CONCRETE
S-304 TYPICAL DETAILS - MASONRY
S-305 TYPICAL DETAILS - MASONRY
S-306 TYPICAL DETAILS - MASONRY
S-307 TYPICAL DETAILS - STEEL
S-308 TYPICAL DETAILS - STEEL
S-309 TYPICAL DETAILS - STEEL
S-310 TYPICAL DETAILS - STEEL
S-401 SECTIONS
S-402 SECTIONS
S-403 SECTIONS
S-404 SECTIONS
S-405 SECTIONS
S-406 SECTIONS
S-500 WALL ELEVATIONS KEY PLAN
S-501 WALL ELEVATIONS
S-502 WALL ELEVATIONS
S-503 WALL ELEVATIONS
S-504 WALL ELEVATIONS
S-505 WALL ELEVATIONS
S-506 WALL ELEVATIONS
S-507 WALL ELEVATIONS
S-508 WALL ELEVATIONS
S-509 WALL ELEVATIONS
S-510 WALL ELEVATIONS
S-601 SCHEDULES
S-602 SCHEDULES
REV DESCRIPTION DATE
T hi s ite m h as b ee n di gi ta lly s ig ne d an d se al ed by
S te vi e
W . L oc kh ar t, P .E
. o n
9/
/2 us in g a di gi ta l s ig na tu re . P rin te d co pi es o f t hi s do cu m en t a re n ot c on si de re d si gn ed a nd se al ed a nd th e
S H
A a ut he nt ic at io n co de m us t be v er ifi ed o n an y el ec tr on ic c op ie s.
NOTE:
THIS DIAGRAM IS A GENERIC AND SIMPLIFIED WALL
PRESSURE DIAGRAM. LOCATION AND WIDTH OF
CORNER ZONES (ZONE 5) CORRESPOND TO ZONE 3
OF THE ACTUAL BUILDING AS SHOWN IN THE ROOF
PRESSURE DIAGRAM ON THIS SHEET.
14'-0", TYP
WIND DESIGN DATA:
BASIC WIND SPEED
CATEGORY (RISK)
EXPOSURE
ENCLOSURE CLASSIFICATION
INTERNAL PRESSURE COEFFICIENT
170 mph (Vult) 132 mph (Vasd)
IV
C
ENCLOSED
± 0.18
CODE:
FLORIDA BUILDING CODE, 2023, ASCE 7-22, ICC 500-20
NOTES:
1. THIS STRUCTURE HAS BEEN DESIGNED AS A HURRICANE STORM SHELTER IN
ACCORDANCE WITH ICC 500-20.
2. GLAZED OPENINGS IN RISK CATEGORY II, III, IV LOCATED IN HURRICANE PRONE
REGIONS SHALL BE PROTECTED IN ACCORDANCE WITH FBC 2023 SEC. 1609.1.2
AND ICC 500-20.
NOTE:
1. ALL EXTERIOR DOORS & WINDOW ASSEMBLIES SHALL SATISFY THE REQUIREMENTS OF THE FLORIDA BUILDING CODE (EIGHTH EDITION 2023, SECTION 1709.5) AND ICC 500-20. ALL CONNECTIONS TO BUILDING STRUCTURE SHALL HAVE THE CAPACITY TO WITHSTAND THE PRESSURES
INDICATED ON SCHEDULES.
2. PLUS AND MINUS SIGNS SIGNIFY PRESSURES ACTING TOWARD AND AWAY FROM THE SURFACES, RESPECTIVELY.
3. ALL WIND PRESSURE VALUES INDICATED ARE IN POUNDS PER SQUARE FOOT (PSF). MULTIPLY ULTIMATE WIND PRESSURE BY 0.60 FOR ASD
PRESSURE.
4. FOR NET UPLIFT CALCULATION, THE WEIGHT OF THE STRUCTURAL MEMBER AND THE STRUCTURAL DECK SUPPORTED ARE THE ONLY TWO
LOADS THAT CAN BE DEDUCTED FROM THE UPLIFT PRESSURES INDICATED ON SCHEDULES.
5. FOR PARAPET WIND PRESSURES:
A. ZONE 4 WINDWARD PARAPET = ZONE 2 ROOF NEGATIVE PRESSURE PLUS ZONE 4 WALL POSITIVE PRESSURE.
B. ZONE 4 WIND LEEWARD PARAPET = ZONE 4 WALL POSITIVE PRESSURE PLUS ZONE 4 NEGATIVE WALL PRESSURE.
C. ZONE 5 WINDWARD PARAPET = ZONE 3 ROOF NEGATIVE PRESSURE PLUS ZONE 5 WALL POSITIVE PRESSURE.
D. ZONE 5 WIND LEEWARD PARAPET = ZONE 5 WALL POSITIVE PRESSURE PLUS ZONE 5 NEGATIVE WALL PRESSURE.
TYP.
21' - 0"
TYP.
7' - 0"
T Y
P
TYP.
7' - 0"
T Y
P
23 3
3oh
3oh
3oh
2oh
2oh
1'
2oh
3oh
2oh
3oh
3oh
2oh
TH
IS
D R
AW
IN
G A
N D
A
LL
IN
FO
R M
AT
IO
N C
O N
TA
IN
ED
H
ER
EI
SO
LE
P R
O
PE
R
TY
O F
M
AS
TE
R
C O
N
SU
LT
IN
G E
N G
IN
EE
. A N
D M
AY
N
O T
BE
R
EP
R
O D
U C
ED
, C
O
PI
ED
, A
LT
ER
ED
D
IN
A N
Y W
AY
W
IT
H
O U
T
TH
E
EX
PR
ES
S W
R
IT
O R
IZ
AT
IO
N
F R
O M
M
AS
TE
R
C O
N
SU
LT
IN
G E
N G
IN
EE
R S, IN
C
W E
S T
C Y
P R
E S
S S
T
S T
E .2
T
A M
P A
, F
LO
R
ID
A
-1
P
3.
7.
3.
7.
C A
TO THE BEST OF OUR KNOWLEDGE, INFORMATION
AND BELIEF, THESE STRUCTURAL PLANS CONFORM
TO AND SATISFY, THE FLORIDA BUILDING CODE,
EIGHTH EDITION 2023, ACI 318-19 AND LOCAL CODES
AS APPLICABLE
S T
E V
IE
W
L O
C K
H A
R T
P
.E
F L L
IC
N o
T H
E A
R C
H
IT
E C
T 'S
C O
M M
O N
L A
W C
O P
Y R
IG
H
T A
H E
R P
R O
P E
R T
Y R
IG
H
T S
A R
E H
E R
E B
Y R
E S
E R
V
H E
I D
E A
S
D E
S
IG
N S
P L A
N S
D
R A
W
IN
G S
A
E C
IF
IC
A T
IO
N
S P
R O
D U
C E
D B
Y T
H E
A R
C H
IT
E
C T
T H
E S E
I D
E A
S
D E
S
IG
N S
P
L A
N S
D
R A
W
IN
G S
A
E C
IF
IC
A T
IO
N
S S
H A
LL
N
O T
B E
R E
P R
O D
U C
E D
N V
E Y
E D
I N
A N
Y M
A N
N E
R N
O R
A S
S
IG
N E
D
Y T
H
IR
D P
A R
T Y
W
IT
H O
U T
F
IR
S T
O B
T A
IN
IN
G T
P R
E S
S W
R
IT
T E
N P
E R
M
IS
S
IO
N O
F T
C H
IT
E
C T
C
O N
S E
N T
I S
H E
R E
B Y
G R
A N
T E
D
V E
R N
M E
N T
A L
A G
E N
C
IE
S T
O R
E P
R O
D U
C E
T
N S T
R U
C T
IO
N
D R
A W
IN
G
S I
N C
O M
P
LI
A N
C E
W
E S
T A
T E
S T
A T
U T
E S
T
O T
H E
B E
S T
O F
T
C H
IT
E
C T
'S O
F E
N G
IN
E
E R
'S K
N O
W
LE
D G
E
T
N S A
N D
S P
E C
IF
IC
A T
IO
N
S C
O M
P
LY
W
IT
H T
P
LI
C A
B L E
M
IN
IM
U
M B
U
IL
D
IN
G C
O D
E S
A N
D T
P
LI
C A
B L E
F
IR
E S
A F E
T Y
S T
A N
D A
R D
S
T E
R M
IN
E
D B
Y T
H E
L O
C A
L A
U T
H O
R
IT
Y
C O
R D
A N
C E
W
IT
H C
H A
P T
E R
S
A N
D
E F
L O
R
ID
A S
T A
T U
T E
S
W J
A rc hi te ct s
A R
(7
2-w .w ja rc
.c om
W an ne m ac he r
Je ns en A rc hi te ct s, In c.
Project number
P R
O J
N O
-1
-1
S-102
WIND DESIGN DATA
AND LOAD SCHEDULE
P A
L M
H A
R B
O R
P A
R K
S A
N D
R E
C R
E A
T
IO
N
P
IN
E
LL
A S
C O
U N
T Y
6T
H S
T R
E E
T , P
A
LM
H A
R B
O R
F L
N E
W R
E C
R E
A T
IO
N
C E
N T
E R
PERMIT SET 9-15-25
SCALE: 1/8" = 1'-0"
WALL PRESSURES DIAGRAM
PARTITIONS 15.0 PSF
MECHANICAL EQUIPMENT 150.0 PSF
STORAGE LIGHT 125.0 PSF
CORRIDORS 80.0 PSF
LOBBIES 100.0 PSF
OFFICE 80.0 PSF
FLOOR FRAMING LIVE LOAD
TOTAL DEAD LOAD - FLOOR FRAMING 87.0 PSF
TOTAL SUPERIMPOSED DEAD LOAD - FLOOR FRAMING 30.0 PSF
MISCELLANEOUS 10.0 PSF
CEILING (5/8" DRYWALL) 3.0 PSF
FIRE SPRINKLERS 3.0 PSF
PLUMBING 3.0 PSF
ELECTRICAL 2.0 PSF
MECHANICAL DUCT ALLOWANCE 4.0 PSF
STEEL FRAMING 5.0 PSF
TOTAL THICKNESS 5 1/2" - REINF. W/ WWF 6X6XW2.1XW2.1
TOPPING OVER BEAMS SPACED AT MAX 8'-0" APART
2" COMPOSITE 20 GAGE DECK W/ 3 1/2" REGULAR WEIGHT CONC. 57.0 PSF
FLOOR FRAMING DEAD LOAD
FLOOR LOAD SCHEDULE
STEEL FLOOR FRAMING
LIVE LOAD (PER ICC 500-20) 50.0 PSF
ROOF FRAMING LIVE LOAD
DEAD LOAD FOR UPLIFT CALCULATION 8.0 PSF
TOTAL DEAD LOAD - ROOF FRAMING 38.0 PSF
MISCELLANEOUS 3.0 PSF
CEILING (5/8" DRYWALL) 3.0 PSF
FIRE SPRINKLERS 3.0 PSF
PLUMBING 3.0 PSF
ELECTRICAL 2.0 PSF
MECHANICAL DUCT ALLOWANCE 4.0 PSF
ROOFING AND INSULATION 12.0 PSF
ROOF METAL DECK 3.0 PSF
STEEL JOISTS / STRUCTURAL FRAMING 5.0 PSF
ROOF FRAMING DEAD LOAD
ROOF LOAD SCHEDULE
STEEL ROOF FRAMING
3oh -215 PSF -191 PSF -160 PSF -136 PSF -113 PSF -82 PSF
2oh -158 PSF -144 PSF -126 PSF -113 PSF -99 PSF -82 PSF
1oh -120 PSF -118 PSF -115 PSF -113 PSF -100 PSF -82 PSF
3 +31 PSF/-215PSF +29 PSF/-194PSF +26 PSF/-168PSF +25 PSF/-147PSF +25 PSF/-127PSF +25 PSF/-101PSF
2 +31 PSF/-158PSF +29 PSF/-147PSF +26 PSF/-134PSF +25 PSF/-124PSF +25 PSF/-114PSF +25 PSF/-101PSF
1 +31 PSF/-120PSF +29 PSF/-112PSF +26 PSF/-101PSF +25 PSF/-93PSF +25 PSF/-86PSF +25 PSF/-75PSF
1' +31 PSF/-69PSF +29 PSF/-69PSF +26 PSF/-69PSF +25 PSF/-69PSF +25 PSF/-59PSF +25 PSF/-47PSF
10 sf 20 sf 50 sf 100 sf 200 sf 500 sf
PATTERN ZONE
EFFECTIVE WIND AREA
COMPONENTS AND CLADDING (ULTIMATE) ROOF PRESSURE SCHEDULE
MAIN BUILDING- ROOF
5 +69 PSF/-92PSF +66 PSF/-86PSF +62 PSF/-78PSF +59 PSF/-72PSF +56 PSF/-65PSF +52 PSF/-57PSF
4 +69 PSF/-75PSF +66 PSF/-72PSF +62 PSF/-68PSF +59 PSF/-65PSF +56 PSF/-61PSF +52 PSF/-57PSF
10 sf 20 sf 50 sf 100 sf 200 sf 500 sf
PATTERN ZONE
EFFECTIVE WIND AREA
COMPONENTS AND CLADDING (ULTIMATE) WALL PRESSURE SCHEDULE
MAIN BUILDING - WALLS
SCALE: 1/16" = 1'-0"
ROOF UPLIFT PRESSURES PLAN
REV DESCRIPTION DATE
T hi s ite m h as b ee n di gi ta lly s ig ne d an d se al ed by
S te vi e
W . L oc kh ar t, P .E
. o n
9/
/2 us in g a di gi ta l s ig na tu re . P rin te d co pi es o f t hi s do cu m en t a re n ot c on si de re d si gn ed a nd se al ed a nd th e
S H
A a ut he nt ic at io n co de m us t be v er ifi ed o n an y el ec tr on ic c op
STRUCTURAL INSPECTION PLAN
PART I
1.01 SCOPE OF WORK
THIS PLAN DESCRIBES WORK REQUIRED TO COMPLY WITH THE THRESHOLD LAW; CHAPTER 553 OF THE FLORIDA STATUTES. THE OWNER SHALL RETAIN A QUALIFIED SPECIAL INSPECTOR TO PERFORM THE WORK DESCRIBED HEREIN. PROPOSALS FOR SPECIAL INSPECTION SERVICES SHALL BE SEPARATE AND INDEPENDENT FROM ALL OTHER PROPOSALS FOR MATERIALS TESTING AND OTHER QUALITY ASSURANCE SERVICES. THE SPECIAL INSPECTOR SHALL VERIFY THAT THE PRIMARY STRUCTURAL FRAME (ALL THOSE MEMBERS WHICH TRANSMIT LOADS TO THE GROUND) IS CONSTRUCTED IN SUBSTANTIAL ACCORDANCE WITH THE PERMITTED OFFICIAL CONTRACT DOCUMENTS, EXCEPT AS VARIATIONS THERE FROM ARE PERMITTED IN WRITING BY THE STRUCTURAL ENGINEER OF RECORD. THIS PLAN MAY BE SUPPLEMENTED BY ADDITIONAL REQUIREMENTS OF THE MUNICIPALITY OR BY THE OWNER AS DEEMED NECESSARY DURING THE COURSE OF THE WORK. THIS DOES NOT INCLUDE INSPECTION OF ANY SAFETY PROVISIONS AS REQUIRED BY OSHA OR OTHER SAFETY STANDARDS WHICH APPLY DURING THE CONSTRUCTION PERIOD, TO ELEMENTS SUCH AS RAILINGS, FIRE PROTECTION, ROOFING, GLAZED WINDOW SYSTEMS, ARCHITECTURAL PRECAST PANELS, MECHANICAL/ELECTRICAL SYSTEMS, ARCHITECTURAL COMPONENTS, SITE WORK AND OTHER ELEMENTS NOT CONTRIBUTING TO THE CAPACITY OF THE PRIMARY STRUCTURAL BUILDING FRAME. THE OFFICIAL CONTRACT DOCUMENTS ARE DEFINED AS THE PERMITTED PLANS, RECORDED ADDENDA, PROJECT SPECIFICATIONS, AMENDMENTS AND THE STRUCTURAL INSPECTION
PLAN.
F. DAILY FIELD REPORTS SHALL BE SUBMITTED ON A WEEKLY BASIS TO THE ENFORCING AGENCY, OWNER'S REPRESENTATIVE, ARCHITECT AND STRUCTURAL ENGINEER OF RECORD, UNDER A COVER LETTER SIGNED AND
SEALED BY THE SPECIAL INSPECTOR.
G. AN INSPECTION LOG SUMMARIZING ALL INSPECTIONS SHALL BE POSTED AT THE JOB SITE AND FILLED OUT EACH DAY AN INSPECTION IS MADE. IT SHALL CONTAIN, AS A MINIMUM: PROJECT NAME, LOCATION, PERMIT NUMBER, SPECIAL INSPECTOR'S NAME, OWNER, CONTRACTOR, DATE OF INSPECTION, CONSTRUCTION PHASE, WORK DESCRIPTION, COMMENTS, APPROVED OR REJECTED AND BE SIGNED BY THE SPECIAL INSPECTOR.
H. UPON COMPLETION OF THE BUILDING AND PRIOR TO THE ISSUANCE OF A CERTIFICATE OF OCCUPANCY, THE SPECIAL INSPECTOR SHALL SUBMIT TO THE ENFORCING AGENCY, OWNER, ARCHITECT AND STRUCTURAL ENGINEER OF RECORD A SIGNED AND SEALED STATEMENT STATING THAT THE PART OF THE PROJECT UNDER HIS INSPECTION RESPONSIBILITIES HAS BEEN CONSTRUCTED IN SUBSTANTIAL ACCORDANCE WITH THE OFFICIAL CONTRACT DOCUMENTS. THIS STATEMENT SHALL BE IN ACCORDANCE WITH SECTION 553.79(7)a OF
THE FLORIDA STATUTES.
I. SINCE THE SPECIAL INSPECTOR DOES NOT CERTIFY THAT THE OFFICIAL CONTRACT DOCUMENTS ARE IN COMPLIANCE WITH THE GOVERNING CODES, ALL STATEMENTS ISSUED WILL REFER TO COMPLETED WORK IN
SUBSTANTIAL ACCORDANCE WITH THE OFFICIAL CONTRACT DOCUMENTS.
1.05 CONTRACTOR REQUIREMENTS
A. THE CONTRACTOR SHALL COOPERATE WITH AND ASSIST THE SPECIAL INSPECTOR IN PERFORMING HIS INSPECTION DUTIES AS SPECIFIED HEREIN. THE SPECIAL INSPECTOR SHALL HAVE FREE ACCESS TO THE
PROJECT AT ALL TIMES.
B. THE CONTRACTOR SHALL ADVISE THE SPECIAL INSPECTOR, IN ADVANCE, OF CONSTRUCTION SCHEDULES AND PLANNED OPERATIONS IN ORDER TO ASSURE TIMELY AND APPROPRIATE OBSERVATION AND INSPECTION OF ITEMS SPECIFIED HEREIN. THE MINIMUM NOTICE GIVEN THE SPECIAL INSPECTOR SHALL BE 24 HOURS PRIOR TO THE TIME OF THE INSPECTION. FURTHER, THE SCHEDULED INSPECTION TIME FOR REINFORCING STEEL SHALL
BE NOT LESS THAN ONE HOUR PRIOR TO THE SCHEDULED CONCRETE PLACEMENT.
C. THE CONTRACTOR SHALL FURNISH IN A TIMELY MANNER TO THE SPECIAL INSPECTOR, COPIES OF ALL REVIEWED AND ACCEPTED SUBMITTALS (EXCLUDING CALCULATIONS) FOR THE STRUCTURAL ELEMENTS OF THE
PROJECT.
D. THE CONTRACTOR SHALL PROVIDE THE SPECIAL INSPECTOR WITH OFFICE FACILITIES AT THE CONSTRUCTION SITE TO ACCOMMODATE HIS NEEDS. AS A MINIMUM, THIS OFFICE, IS TO BE EQUIPPED WITH THE FOLLOWING ITEMS: DESK, CHAIR, PLAN TABLE, PLAN RACK, FILING CABINET, TELEPHONE, UTILITIES, AIR CONDITIONING AND
JANITORIAL SERVICES.
E. SPECIAL INSPECTIONS DO NOT RELIEVE THE CONTRACTOR OF HIS RESPONSIBILITY TO COMPLY WITH THE CONTRACT DOCUMENTS, ANY STATUTORY OR CONTRACTUAL OBLIGATIONS, NOR HIS RESPONSIBILITIES TO CARRY OUT HIS QUALITY CONTROL INSPECTIONS AND TESTING. THE CONTRACTOR HAS THE SOLE RESPONSIBILITY FOR ANY DEVIATIONS FROM THE OFFICIAL CONTRACT DOCUMENTS AND THE COSTS OF
RECTIFYING THOSE DEVIATIONS.
F. WORK WHICH IS IN NON-COMPLIANCE WITH THE OFFICIAL CONTRACT DOCUMENTS MAY BE CORRECTED BY THE CONTRACTOR OR THE CONTRACTOR MAY SUBMIT TO THE ARCHITECT/ENGINEER A REQUEST FOR ACCEPTANCE
OF THE DEVIATION.
G. CONSTRUCTION PERFORMED WITHOUT INSPECTION AND THAT IS UNABLE TO BE INSPECTED MAY REQUIRE
TESTING OR REMOVAL AS DETERMINED BY THE STRUCTURAL ENGINEER OF RECORD.
H. THE SPECIAL INSPECTOR CAN NOT MAKE THE REQUIRED COMPLETION STATEMENT AND THE BUILDING WILL NOT RECEIVE A CERTIFICATE OF OCCUPANCY IF WORK IS NOT IN SUBSTANTIAL ACCORDANCE WITH THE OFFICIAL CONTRACT DOCUMENTS, OR IF CONSTRUCTION IS PERFORMED WITHOUT INSPECTION AND IS UNABLE
TO BE INSPECTED.
I. INSTALLATION OF ALL SHORING AND RE-SHORING SHALL BE IN ACCORDANCE WITH THE SIGNED AND SEALED SHORING AND RE-SHORING DRAWINGS PREPARED BY THE DELEGATED SHORING ENGINEER. THE DELEGATED SHORING ENGINEER OR HIS AUTHORIZED REPRESENTATIVE SHALL INSPECT AND ENSURE THAT THE DRAWING REQUIREMENTS AND SPECIFICATIONS ARE ADHERED TO, AND PROVIDE HIS WRITTEN REPORT TO THE SPECIAL INSPECTOR PRIOR TO ALL CONCRETE POURS. THE SPECIAL INSPECTOR IS TO VERIFY THAT THE INSPECTION IS PERFORMED AND IS TO OBSERVE THAT THE WORK APPEARS TO BE IN COMPLIANCE WITH THE DRAWINGS.
D. BEAMS:
INSPECT REINFORCING STEEL. CHECK TIE SPACING, INCLUDING LOCATION OF FIRST TIE. CHECK FOR HOOKED
BOTTOM BARS. CHECK THAT HOOKED BARS EXTEND TO FAR FACE OF SUPPORT.
E. ONE WAY SLABS:
INSPECT REINFORCING STEEL, INCLUDING TEMPERATURE STEEL. CHECK THAT HOOKED BARS EXTEND TO FAR
FACE OF SUPPORT.
F. TWO WAY SLABS:
INSPECT REINFORCING STEEL. CHECK FOR PROPER LAYERING. CHECK PLACEMENT OF TOP BARS THROUGH COLUMNS STRIP FOR UNIFORM SPACING (BARS ARE NOT TO BE TO TIED TOGETHER). CHECK THAT ADDED TOP BARS ARE PLACED WITHIN THE VICINITY OF THE COLUMNS. CHECK THAT ADDED BOTTOM BARS EXTEND TO FACE OF COLUMN, UNLESS OTHERWISE SHOWN ON CONTRACT DOCUMENTS, AND THAT THEY ARE WITHIN THE COLUMN STRIP. CHECK HOOK BAR REQUIREMENTS, TOP AND BOTTOM. CHECK THAT HOOKS ARE PLACED AT
FAR FACE OF SUPPORT. CHECK POSITION OF BARS AT SLAB OFFSETS AND DEPRESSIONS.
G. POST-TENSIONING: (NOT USED)
H. PRECAST/PRESTRESSED COMPOSITE CONCRETE: (NOT USED)
I. STRUCTURAL PRECAST CONCRETE: (NOT USED)
J. CHECK THAT EXPANSION JOINT MATERIAL, ANCHORS AND OTHER EMBEDDED ITEMS ARE CORRECT AND HAVE
BEEN POSITIONED AND SECURED IN PLACE SO THAT DISPLACEMENT IS NOT POSSIBLE.
1. CHECK THAT CONDUITS PLACED IN THE SLAB ARE REASONABLY SPACED TO ENSURE INTEGRITY OF THE
SLAB.
2. CONFIRM THAT LOAD CARRYING EMBEDDED ITEMS ARE PLACED IN COMPLIANCE WITH THE CONTRACT
DOCUMENTS. RELOCATION OF EMBEDDED ITEMS IN CONFLICT WITH REINFORCING WILL NOT BE
PERMITTED WITHOUT PRIOR APPROVAL OF THE ARCHITECT/ENGINEER.
K. CHECK THAT CONSTRUCTION JOINTS, INCLUDING DOWELS, KEYS AND BULKHEADS, ARE IN CONFORMANCE WITH THE CONTRACT DOCUMENTS. REVIEW THE LOCATION OF CONSTRUCTION JOINTS IN BEAMS AND SLABS FOR COMPLIANCE WITH THE CONSTRUCTION JOINT LOCATION PLAN SUBMITTED BY THE CONTRACTOR TO THE
ARCHITECT/ENGINEER.
L. OPENINGS:
1. REPORT ALL SLAB OPENINGS LARGER THAN 12" AND NOT SHOWN ON THE CONTRACT DOCUMENTS TO THE ARCHITECT/ENGINEER. CHECK PLACEMENT OF ADDITIONAL REINFORCEMENT AROUND OPENINGS. NO
SLEEVES OR OPENINGS WILL BE PERMITTED IN BEAMS WITHOUT PRIOR APPROVAL OF THE
ARCHITECT/ENGINEER.
M. CHECK THAT ALL FOREIGN MATERIAL HAS BEEN REMOVED FROM SPACES WHICH CONCRETE IS TO OCCUPY.
2.06 STRUCTURAL STEEL
A. INSPECT STRUCTURAL STEEL PRIOR TO CONCEALMENT TO VERIFY GRADE, SIZES, CONNECTIONS, STRAIGHTNESS AND FINISH. CHECK WITH CONTRACT DOCUMENTS AND SHOP DRAWINGS.
B. INSPECT SETTING OF ANCHOR BOLTS, EMBEDS AND OTHER MISCELLANEOUS STRUCTURAL ITEMS PRIOR TO
CONCRETING. VERIFY, SIZE, QUANTITY AND FINISH.
C. INSPECT CONNECTIONS FOR THE FOLLOWING:
1. BOLTED CONNECTIONS: TYPE, SIZE AND NUMBER OF BOLTS. CHECK THAT BOLTS ARE CLEAN AND LUBRICATED AND HAVE PROPER WASHERS AND THAT THEY CONFORM TO THE SPECIFICATIONS. CHECK THAT BOLT HOLES ARE THE SPECIFIED TYPE AND SIZE. VERIFY THAT BOLTS ARE PROPERLY TIGHTENED.
FOR SLIP-CRITICAL BOLTS WITH LOAD INDICATOR WASHERS, CHECK ALL BOLTS VISUALLY AND 10% WITH A
FEELER GAUGE. "TURN OF THE NUT" METHOD IS NOT ACCEPTABLE.
2. WELDED CONNECTIONS: VERIFY THAT WELDERS ARE AWS CERTIFIED FOR THE TYPE OF WELDS BEING MADE. VISUALLY EXAMINE ALL WELDS FOR TYPE, SIZE AND LENGTH FOR COMPLIANCE WITH THE STRUCTURAL DRAWINGS. VERIFY THAT REQUIRED NON-DESTRUCTIVE TESTING IS PERFORMED BY THE TESTING AGENCY. VERIFY THAT WELDS ARE CLEAN, FREE FROM SLAG, AND THAT RUST PROTECTION HAS
BEEN APPLIED AS PER SPECIFICATIONS.
1.02 QUALIFICATIONS OF THE SPECIAL INSPECTOR
A. SPECIAL INSPECTOR SHALL BE A FLORIDA REGISTERED ENGINEER EXPERIENCED IN STRUCTURAL ENGINEERING AND CERTIFIED AS REQUIRED BY CURRENT LEGISLATION. SPECIAL INSPECTOR MUST BE
CURRENTLY ACTIVE IN THE DESIGN OF BUILDING STRUCTURES.
B. SPECIAL INSPECTOR SHALL NOT PERFORM THE MATERIAL TESTING FOR THE PROJECT.
C. THE SPECIAL INSPECTOR MAY SEND A FULL-TIME EMPLOYEE AS HIS AUTHORIZED REPRESENTATIVE TO THE PROJECT, BUT THAT PERSON SHALL BE EXPERIENCED AND KNOWLEDGEABLE IN THE STRUCTURAL SYSTEM BEING USED AND THE APPROPRIATE PORTIONS OF THE GOVERNING CODES AND STANDARDS.
AUTHORIZED REPRESENTATIVE SHOULD HAVE AS A MINIMUM AN ENGINEERING DEGREE FROM AN
ACCREDITED COLLEGE.
D. THE SPECIAL INSPECTOR SHALL HAVE A MINIMUM OF SEVEN (7) YEARS OF EXPERIENCE IN DESIGN AND INSPECTION OF SIMILAR STRUCTURES AND SHALL HAVE BEEN ENGINEER OF RECORD IN AT LEAST (4) SIMILAR STRUCTURES. THE SPECIAL INSPECTOR'S REPRESENTATIVE SHALL HAVE ENGINEERING COLLEGE DEGREE AND OBTAINED HIS "EI", SHALL HAVE DESIGN AT LEAST (1) SIMILAR STRUCTURE AND HAVE AT LEAST (3) YEARS OF EXPERIENCE IN INSPECTION OF SIMILAR STRUCTURES. RESUMES OF BOTH THE SPECIAL INSPECTOR AND SPECIAL INSPECTOR'S REPRESENTATIVE SHALL BE SUBMITTED TO
THE OWNER'S REPRESENTATIVE, THE ENFORCING AGENCY HAVING JURISDICTION AND THE
STRUCTURAL ENGINEER OF RECORD FOR REVIEW…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .