24-HVAC Building A and C.pdf

PDF 1 MB Posted

Attached to
DPD Oakman Renovation – Building A & C at 1180 Oakman
Solicitation number
542713
Issued by
Wayne County, Detroit City, Michigan

About this file

This is a schematic design document for HVAC renovations at the City of Detroit's Detroit Police Department facility located at 1180 Oakman Boulevard, involving Buildings A and C. The proposed work includes installation of new exhaust systems for shower rooms (120C and 120D in Building A), replacement of the HVAC control system, and replacement of grilles as specified. Building A encompasses multiple floors with designated areas including offices, mechanical rooms, locker rooms, interview spaces, and support facilities, while Building C includes armory spaces, offices, corridors, and drive aisles. The schematic design review was issued on January 30, 2025, with floor plans provided at a scale of 3/32 inches equals 1 foot, covering the first and second floors of Building A and the main floor of Building C. General notes indicate that no special HVAC requirements are assumed for certain armory spaces (101, 102, 103), with the design of Armory 104 to be completed by others and not included in the current contract scope.

The document does not contain specific pricing information, contract award dates, response deadlines, or other commercial terms. The schematic design represents an early phase of the project development process and serves as a foundation for detailed design and eventual construction. No information regarding incumbents, funding sources, set-asides, or renewal options is included in this technical drawing package.

View the file

Other files

File Type Posted
3-Attachment D-1 Required Forms Affidavits.pdf PDF
26-RFP 542713 DPD Oakman.pdf PDF
10-Attachment F-3 - Bid Bond.pdf PDF
4-Attachment D-2 - Conditions of Award.pdf PDF
9-Attachment F-1 - Performance Bond.pdf PDF
8-Attchment C1 Price Proposal.xlsx XLSX spreadsheet
19-Arch Building A.pdf PDF
16-Fire Suppression Building C 3.pdf PDF
11-Attachment F-2 - Payment Bond.pdf PDF
14-Attachment G1 Organizational Chart (10).docx DOCX document
6-Attachment B - Respondent Proposal Introduction and Solution Approach.docx DOCX document
17-Attachment I Leadership Team (9).docx DOCX document
23-Fire Suppression Building C 3.pdf PDF
25-Electrical Building A.pdf PDF
22-Fire Suppression Building C 1.pdf PDF
12-Attachment H Committed Work Capacity (7) (1).xlsx XLSX spreadsheet
1-Attachment E - Professional Service Contract Sample.docx DOCX document
15-Attachment J Experience References (7) (1).xlsx XLSX spreadsheet
5-Attachment A - Respondent Questionnaire RFP.docx DOCX document
13-Attachment G2 Staff Roster (7).xlsx XLSX spreadsheet
7-Attchment C2 Price Proposal.xlsx XLSX spreadsheet
18-Arch Building C (1).pdf PDF
21-Fire Suppression Building C 2.pdf PDF
20-Electrical Building C.pdf PDF
2-Equalization Credit Statement.pdf PDF
Show all 25

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

WALKWAY ABOVE WALKWAY ABOVE

NOT IN CONTRACT

CORR.

120B

VEST

119E

CLO

119D

CLO

119C

MENS

TOILET

119B

WOMENS

TOILET

119A

LOBBY

120G

OFFICE

120S

TOILET

120F

TOILET

120E

SHOWER

120D

SHOWER

120C

BREAK

ROOM

120H

GYM

120A

VESTIBULE

OFFICE

OFFICE

MECH

CLO

115A

OFFICE

STAIR

STAIR

POLICE

RECORDS

TEL/COM

113B

MECHANICAL

ROOM

113A

DPD

RECORDS

ROOM

MECHANICAL

ROOM

ELECTRICAL

ROOM

TEL/COM

121C

ELEV.

EQUIP.

CLO.

102D

OPEN

OFFICE

TOILET

100D

INTERVIEW

001C

LOBBY

100B

VEST.

100A

STAIR

OFFICE

121B OFFICE

121A

OFFICE

CONF.

MECH

VEST

103E

CLO

103D

CLO

103C

MENS

TOILET

103B

WOMENS

TOILET

103A

TOI

102G

TOI

102F

VEST.

102E

OFFICE

102COFFICE

102B

OFFICE

102A

DoIT

RECORDS

106B

DoIT

RECORDS

BREAK

ROOM

109B

KITCH

109A

STAIR

OFFICE

107A

DoIT

RECORDS

OFFICE

108A

DoIT

RECORDS

OFFICE

108B

DoIT

RECORDS

OFFICE

108C

VEST.

107B

DoIT

RECORDS

106A

NOT IN SCOPE

1180 OAKMAN

SHEET NO.

FILE NO.

APPROVED

CHECKED

DRAWN BY

SCALE:

SHEET TITLE

DATEISSUED FOR

BUILDING C

BUILDING A

DETROIT, MI 48204

RENOVATIONS

DPD OAKMAN

BUILDING A

PROPOSED HVAC

FIRST FLOOR PLAN

AS NOTED

MH-201

SCHEMATIC DESIGN REVIEW 01/30/2025

SCALE:

BUILDING A FIRST FLOOR HVAC

3/32"=1'-0"

1. SCOPE OF WORK INCLUDES:

HVAC GENERAL NOTES:

NEW EXHAUST SYSTEM FOR NEW SHOWER ROOMS 120C.D

REPLACEMENT OF CONTROL SYSTEM

REPLACEMENT OF GRILLES ONLY*

AutoCAD SHX Text

NORTH

AutoCAD SHX Text

KEY PLAN

AutoCAD SHX Text

TRUE NORTH

OPEN TO BELOW

OPEN TO BELOW

889 SQ. FT.

1,116 SQ. FT.

867 SQ. FT.

STO.

OFFICE

221K

OFFICE

221J

OFFICE

221H

OFFICE

OFFICE

221GOFFICE

221F

OFFICE

221E

OFFICE

221D

OFFICE

221C

OFFICE

221B

OFFICE

221A

OPEN

OFFICE

219OFFICE

OPEN

OFFICE

MENS

TOILET

216B

STAIR

IT

CLO.

212B

MECHANICAL

WALKWAY

230B

WALKWAY

230A

VEST

216E

CLO

216D

CLO

216C

WOMENS

TOILET

216A

OPEN

OFFICE

OPEN

OFFICE

OPEN

OFFICE

OPEN

OFFICE

212A

STAIR

STAIR

MECHANICAL

STORAGE

211 MECHANICAL

STAIR

OPEN

OFFICE

OPEN

OFFICE

WALKWAY

230D

WALKWAY

230C

OPEN

OFFICE

WOMENS

LOCKER

ROOM

VEST

205E

CLO

205D

CLO

205C

MENS

TOILET

205B

WOMENS

TOILET

205A

MENS

LOCKER

ROOM

BREAK

ROOM

203C

OFFICE

203OFFICE

203A

STO

202B

OPEN

OFFICE

202A

TASER

STO.

LOBBY

200B

NOT IN SCOPE

1180 OAKMAN

SHEET NO.

FILE NO.

APPROVED

CHECKED

DRAWN BY

SCALE:

SHEET TITLE

DATEISSUED FOR

BUILDING C

BUILDING A

DETROIT, MI 48204

RENOVATIONS

DPD OAKMAN

BUILDING A

PROPOSED HVAC

SECOND FLOOR PLAN

AS NOTED

MH-202

SCHEMATIC DESIGN REVIEW 01/30/2025

SCALE:

BUILDING A SECOND FLOOR HVAC

3/32"=1'-0"

1. SCOPE OF WORK INCLUDES:

HVAC GENERAL NOTES:

NEW EXHAUST SYSTEM FOR NEW SHOWER ROOMS 120C.D

REPLACEMENT OF CONTROL SYSTEM

REPLACEMENT OF GRILLES ONLY*

AutoCAD SHX Text

NORTH

AutoCAD SHX Text

KEY PLAN

AutoCAD SHX Text

TRUE NORTH

WOMEN

CLOSET

LOBBY

MEN

OPEN

OFFICE

CLOSET

CORR.

CORR.

CORR.

IT.

CLOSET

CLOSET

IT. CLOSET

BREAK

ROOM

OFFICE

OFFICE

OFFICE

OFFICE

STORAGE

STORAGE

OFFICE

OFFICE

OFFICE

OFFICE

OPEN

OFFICE

OPEN

OFFICE

DRIVE

AISLE

DRIVE

AISLE

CORRIDOR

DRIVE

AISLE

ARMORY

ARMORY

ARMORY

OFFICE

VEST.

TOILET

TOILET

ARMORY

VEST.

10987654321

A

A.2

B

C

D

T

T

ECUH-1

T

RTU-1

RTU-2

T

T

NOT IN SCOPE

UP TO

ROOFEF

RTU-5RTU-4

UP TO

ROOFEF

UP TO

ROOF

RTU-3

DRIVE

AISLE

1180 OAKMAN

SHEET NO.

FILE NO.

APPROVED

CHECKED

DRAWN BY

SCALE:

SHEET TITLE

DATEISSUED FOR

BUILDING C

BUILDING A

DETROIT, MI 48204

RENOVATIONS

DPD OAKMAN

BUILDING C

PROPOSED HVAC

FLOOR PLAN

AS NOTED

MH-210

SCHEMATIC DESIGN REVIEW 01/30/2025

SCALE:

BUILDING C FIRST FLOOR HVAC

3/32"=1'-0"

1. WE ASSUME NO SPECIAL HVAC REQUIREMENTS

FOR ARMORY 101, 102, 103

HVAC GENERAL NOTES:

2. DESIGN OF ARMORY 104 BY OTHERS- NIC

AutoCAD SHX Text

NORTH

AutoCAD SHX Text

KEY PLAN

AutoCAD SHX Text

TRUE NORTH

bautistar Polygon Sketch to Scale

0.97 sf bautistar Architect

NOTE IN SCOPE

Sheets and Views
MH-201
Sheets and Views
M-202
Sheets and Views
MH-210

File details come from the government source that posted it. Updated .