21-Attachment E - Senior Center Roof Plans - A06-A700.pdf
PDF 6 MB Posted
- Attached to
- Senior Center Roof Project
- Solicitation number
- IFB-032-26-KM
- Issued by
- Leon County, Florida
About this file
This is an architectural roof plans document for the City of Tallahassee's Senior Center Building Roof Repairs project located at 1400 N Monroe Street, Tallahassee, Florida 32303. The project scope includes high-pressure washing of the existing roof surface, full adhesion of a new 80 mil fleece-backed single-ply polyvinyl chloride (PVC) membrane roofing system with low-rise foam, and heat welding of seams and laps per roofing manufacturer specifications. Additional work encompasses removal and replacement of existing wall base flashing, skylight roof hatch, and exhaust fan curb flashing with 60 mil PVC membrane flashing; application of liquid-applied flashing at ventilation and roof penetrations with manufacturer-approved PVC boots; cleaning, priming, and painting of roof drains, bowls, clamping rings, and metal basket strainers with stainless steel bolt replacements; installation of reinforced liquid-applied membrane flashing; and installation of new reinforced aluminum gutters and downspouts. The plans document is dated August 12, 2025, with project number 171824 and was prepared by MLD Architects of Tallahassee, Florida.
The architectural plans provided include a legend identifying work items typical to the scope and reference additional details, drawings, and specifications contained in other contract documents. The plans contain twelve photo markers referencing site condition documentation on sheet A700, though the actual photographs are not included in this document. The scope of work described in the roof plans is intended to supplement the drawings and clarify the complete scope of work, though it is noted that work legend items are typical for the situations shown and may not be all-inclusive unless otherwise specified in the solicitation documents.
View the file
Other files
Show all 21
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
D# 3'x7'
W#
A500
EXISTING CMU WALL
EXISTING CMU WALL TO BE REMOVED
EXISTING PARTITION WALL TO BE REMOVED
INTERIOR WALL - 3 5/8" METAL STUDS WITH
5/8" GYPSUM BOARD BOTH SIDES. PRIME
AND PAINT TWO COATS.
INFILLED SECTION OF WALL/ DOOR/
WINDOW. INFILL ALL INDICATED OPENINGS
TO MATCH EXISTING CONSTRUCTION AND
FINISH.
ELEVATION/SECTION NUMBER
SHEET NUMBER
WORK LEGEND NOTE
PHOTO MARKER
PHOTO # / SHEET #
N.I.C.
A.F.F.
SIM.
TYP.
MIR.
NEW DOOR, SEE DOOR
SCHEDULE, SHEET A000
EXISTING DOOR TO
REMAIN
EXISTING DOOR TO BE
REMOVED
NEW WINDOW, SEE
WINDOW SCHEDULE,
SHEET A000
EXISTING WINDOW TO
REMAIN
EXISTING WINDOW TO
BE REMOVED
ROOM NAME & NUMBER
NOT IN CONTRACT
ABOVE FINISH FLOOR
SIMILAR
TYPICAL
MIRROR
1/A100
ROOM
AR96289
BUILDING ENVELOPE
211 JOHN KNOX RD, SUITE 105
TALLAHASSEE, FL 32303
PH: (850) 385 9200
MLDARCHITECTS.COM
LEGEND
CONSULTANTS
A700
PERMIT SET
PROJ. NO.
DATE
DRAWN
CHECKED
APPROVED
REVISION
REVISION DATE
171824
08/12/2025
KR
RB
JS
Layout
CONSULTANTS
TA
LL
A H
A
SS
EE
, F
LO
RI
D A
SE
N
IO
R
C
EN
TE
R
BU
IL
D
IN
G R
O O
F
RE
PA
IR
S
C
ITY
O F
TA
LL
A H
A
SS
EE
1 HIGH PRESSURE WASH THE EXISTING ROOF SURFACE TO BE FREE OF DEBRIS AND LOOSE
ROOFING GRANULES. FULLY ADHERE NEW 80 MIL FLEECE BACKED SINGLE-PLY POLYVINYL
CHLORIDE (PVC) MEMBRANE ROOFING WITH LOW RISE FOAM. HEAT WELD SEAMS AND
LAPS IN ACCORDANCE WITH ROOFING MANUFACTURER'S RECOMMENDATIONS.
REMOVE EXISTING WALL BASE FLASHING, SKYLIGHT ROOF HATCH AND EXHAUST FAN
CURB FLASHING AND FULLY ADHERE 60 MIL PVC MEMBRANE FLASHING.
APPLY LIQUID APPLIED FLASHING AT VTR BASE, INSTALL MANUFACTURER'S APPROVED
PVC BOOT WITH DRAW BAND. SEAL TOP EDGE OF BOOT AND APPLY TWO COATS
PREMIUM ACRYLIC PAINT ON EXPOSED PIPE.
CLEAN, PRIME AND PAINT 2 COATS ROOF DRAINS, BOWLS, CLAMPING RINGS AND METAL
BASKET STRAINERS. REPLACE EXISTING BOLTS WITH STAINLESS STEEL BOLTS.
APPLY REINFORCED LIQUID APPLIED MEMBRANE FLASHING PER THE MANUFACTURER'E
REQUIREMENT.
REINSTALL SALVAGED METAL COPING WITH SEALED JOINT COVERS.
INSTALL NEW REINFORCED ALUMINUM GUTTER AN DOWNSPOUTS.
THESE WORK ITEMS ARE TYPICAL AND MAY NOT BE ALL INCLUSIVE BUT INTENDED TO
SUPPLEMENT THE DRAWINGS AND DETAILS AND CLARIFY THE SCOPE OF WORK. WORK LEGEND
ITEMS ARE TYPICAL FOR SITUATIONS AND WORK SCOPE SHOWN. WORK LEGEND SYMBOLS ARE
NOT SHOWN AT EVERY SPECIFIC LOCATION WHICH SCOPE IS TO BE COMPLETED, UNLESS
OTHERWISE NOTED.
2 PHOTO 2
A700
3 PHOTO 3
A700
4 PHOTO 4
A700
5 PHOTO 5
A700
6 PHOTO 6
A700
7 PHOTO 7
A700
8 PHOTO 8
A700
1 PHOTO 1
A700
10 PHOTO 10
A700
11 PHOTO 11
A700
12 PHOTO 12
A700SCALE: 1:6.43
9 PHOTO 9
A700
7 11
11 11
WORK NOTES
| 2025-08-13T12:41:34-0400 | |
| Jerry A Scott |
File details come from the government source that posted it. Updated .