18-Attachment E - Senior Center Roof Plans - A03-A100.pdf
PDF 431 KB Posted
- Attached to
- Senior Center Roof Project
- Solicitation number
- IFB-032-26-KM
- Issued by
- Leon County, Florida
About this file
This is a roof plan document prepared by MLD Architects for the City of Tallahassee's Senior Center Building Roof Repairs project located at 1400 N Monroe Street, Tallahassee, Florida. The project scope includes high-pressure washing of the existing roof surface, installation of an 80 mil fleece-backed single-ply polyvinyl chloride (PVC) membrane roofing with low-rise foam adhesive, heat-welded seams, and replacement of flashing systems including removal and reinstallation of wall base flashing, skylight flashing, and exhaust fan curb flashing with 60 mil PVC membrane. Additional work includes application of liquid-applied flashing at the vertical turbine riser (VTR) base with manufacturer-approved PVC boots, painting of roof drains and metal components with stainless steel bolt replacement, installation of reinforced aluminum gutters and downspouts, and reinstallation of salvaged metal coping with sealed joint covers. The roof plan drawing (A100) is dated August 12, 2025, and identifies nine distinct roof sections (Roofs A through I) with corresponding work details and reference sheets for supplemental drawings and specifications.
The document serves as the permit set architectural drawing for the roofing project with a project number of 171824. The plan indicates that work items shown in the roofing legend are typical applications intended to supplement the full drawings and specifications, with additional details and sections referenced throughout the construction documents. The scope emphasizes adherence to roofing manufacturer's requirements for material installation and sealing applications, indicating a performance-based approach to material and workmanship standards.
View the file
Other files
Show all 21
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
AR96289
BUILDING ENVELOPE
211 JOHN KNOX RD, SUITE 105
TALLAHASSEE, FL 32303
PH: (850) 385 9200
MLDARCHITECTS.COM
A500
VTR
LOW PARAPET WALL
EXHAUST FAN
ABANDONED CAPPED
ROOD CURB
EXISTING SKYLIGHT N.I.C.
NEW SKYLIGHT
VTR
SCUPPER
ABANDONED SLEEPERS TO
BE REMOVED
ROOF DRAIN
ABANDONED SOLAR PANEL
TO BE REMOVED
SLOPE
PHOTO MARKER
PHOTO # / SHEET #
CRICKET
SECTION #
SHEET #
LOW/HIGH
WORK LEGEND NOTE
NOT IN CONTRACT
SIAMESE FIRE HOSE
CONNECTION / STAND PIPE
CHIMNEY
EQUIPMENT HATCH
GUTTER & DOWNSPOUT
ANTENNA TO BE REMOVED
L
1/A700
EF
N.I.C.
S
EX
RD
DS
A
1 HIGH PRESSURE WASH THE EXISTING ROOF SURFACE TO BE FREE OF DEBRIS AND LOOSE
ROOFING GRANULES. FULLY ADHERE NEW 80 MIL FLEECE BACKED SINGLE-PLY POLYVINYL
CHLORIDE (PVC) MEMBRANE ROOFING WITH LOW RISE FOAM. HEAT WELD SEAMS AND
LAPS IN ACCORDANCE WITH ROOFING MANUFACTURER'S RECOMMENDATIONS.
REMOVE EXISTING WALL BASE FLASHING, SKYLIGHT ROOF HATCH AND EXHAUST FAN
CURB FLASHING AND FULLY ADHERE 60 MIL PVC MEMBRANE FLASHING.
APPLY LIQUID APPLIED FLASHING AT VTR BASE, INSTALL MANUFACTURER'S APPROVED
PVC BOOT WITH DRAW BAND. SEAL TOP EDGE OF BOOT AND APPLY TWO COATS
PREMIUM ACRYLIC PAINT ON EXPOSED PIPE.
CLEAN, PRIME AND PAINT 2 COATS ROOF DRAINS, BOWLS, CLAMPING RINGS AND METAL
BASKET STRAINERS. REPLACE EXISTING BOLTS WITH STAINLESS STEEL BOLTS.
APPLY REINFORCED LIQUID APPLIED MEMBRANE FLASHING PER THE MANUFACTURER'E
REQUIREMENT.
REINSTALL SALVAGED METAL COPING WITH SEALED JOINT COVERS.
INSTALL NEW REINFORCED ALUMINUM GUTTER AN DOWNSPOUTS.
THESE WORK ITEMS ARE TYPICAL AND MAY NOT BE ALL INCLUSIVE BUT INTENDED TO
SUPPLEMENT THE DRAWINGS AND DETAILS AND CLARIFY THE SCOPE OF WORK. WORK LEGEND
ITEMS ARE TYPICAL FOR SITUATIONS AND WORK SCOPE SHOWN. WORK LEGEND SYMBOLS ARE
NOT SHOWN AT EVERY SPECIFIC LOCATION WHICH SCOPE IS TO BE COMPLETED, UNLESS
OTHERWISE NOTED.
ROOFING LEGEND
CONSULTANTS
A100
PERMIT SET
PROJ. NO.
DATE
DRAWN
CHECKED
APPROVED
REVISION
REVISION DATE
171824
08/12/2025
KR
RB
JS
ROOF PLAN
WORK NOTES
CONSULTANTS
TA
LL
A H
A
SS
EE
, F
LO
RI
D A
SE
N
IO
R
C
EN
TE
R
BU
IL
D
IN
G R
O O
F
RE
PA
IR
S
C
ITY
O F
TA
LL
A H
A
SS
EE
VTR
VTR
VTR
EF
EF
EF
EF
HATCH
VTR
ROOF A
A
DS DSDS DS
VTR
EF
EF
S
S
EX
L
ROOF B
R O
O F
C
ROOF D
ROOF F ROOF G ROOF H
ROOF E
DS DS
RD
RD RD RD
RDRDRD
CHIM
DS
DS
DS
L
L L
ROOF I
N.I.C.
H
L
H1 A500
A501
A501
A501
A500
A500
A500
A500
A500
A500
A500
A500
A500
A500
A501
A501
A500
A500
A501
A501
A501
A501
A501
A501
A501
A500
±16' ±14' ±88' ±14' ±16' ±3'-8"±31'-6"
'-6
'-1
±2'-6"
A500
A500
A500
A501
A501
A501
A501
A501
A501
N
SCALE: 1/8" = 1'-0"
1 ROOF PLAN
A100 0 4' 8' 16'
SEE STRUCTURAL DRAWINGS
PROVIDED BY OWNER
| 2025-08-13T12:42:29-0400 | |
| Jerry A Scott |
File details come from the government source that posted it. Updated .