About this file
This architectural permit set document contains detailed roof repair plans for the Senior Center building project in the City of Tallahassee, Florida. The plans specify a comprehensive roof replacement system involving the removal of existing mineral-surfaced modified bitumen roofing membrane and the installation of a fully adhered 80 mil fleece-back polyvinyl chloride (PVC) roofing system with 60 mil PVC flashing membrane throughout the structure. The project includes multiple technical specifications and details for various roof penetrations and conditions, including ventilation piping extensions, scupper details for roof drainage, parapet wall treatments, exhaust fan installations, gooseneck conduit details, eyebrow wall base flashing, roof hatch treatments, and pipe penetration flashings. All roofing components are to be installed according to manufacturer requirements, with provisions for silicone sealant applications, stainless steel fastening systems with neoprene washers spaced at eight-inch centers, and prefinished aluminum coping covers with sealed joint laps. The permit set includes nine detailed construction drawings, each scaled at three inches to one foot, prepared by the project consultants and approved for permit purposes with a revision date of August 12, 2025.
The document serves as the technical specification foundation for contractors bidding on the Senior Center roof project, establishing the material standards and installation methodologies required for project completion. All materials specified include high-performance components such as premium acrylic coating systems for ultraviolet protection of exposed piping and lightweight tapered concrete insulation systems for thermal performance. The plans demonstrate a complete roof system replacement addressing structural drainage, weather protection, and long-term durability of the existing building envelope.
View the file
Other files
Show all 21
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
CONSULTANTS
A500
PERMIT SET
PROJ. NO.
DATE
DRAWN
APPROVED
REVISION
REVISION DATE
08/12/2025
DETAILS
CHECKED
171824
KR
RB
JS
CONSULTANTS
TA
LL
A H
A
SS
EE
, F
LO
RI
D A
SE
N
IO
R
C
EN
TE
R
BU
IL
D
IN
G R
O O
F
RE
PA
IR
S
C
ITY
O F
TA
LL
A H
A
SS
EE
EXTEND EXISTING V.T.R. PIPING TO BE
MINIMUM 10" ABOVE FINISHED ROOF
FULLY ADHERED 80 MIL FLEECE BACK
PVC ROOFING SYSTEM
MANUFACTURER'S PVC BOOT
FLASHING PRIME AND PAINT
EXPOSED AREA OF
PIPE WITH PREMIUM
ACRYLIC COATING
SYSTEM TO PROTECT
FROM U.V.
S.S. DRAW BAND
CLEANED EXISTING MINERAL SURFACED
MODIFIED BITUMEN ROOFING MEMBRANE
REINFORCED LIQUID APPLIED FLASHING
VERIFY
EXISTING TAPERED LIGHTWEIGHT
CONCRETE INSULATION SYSTEM NEW LEADERHEAD AND
DOWNSPOUT TO
MATCH EXISTING
SILICONE SEALANT
PREFINISHED ALUMINUM COPING
COVER WITH SEALED JOINT LAPS
ADHERED 60 MIL PVC FLASHING SYSTEM WITH
LIGHTWEIGHT VENTS AT 18' O.C.
PVC CLAD STAINLESS STEEL SCUPPER
THROAT
EXISTING TAPERED LIGHTWEIGHT CONCRETE
INSULATION SYSTEM
CLEANED EXISTING MODIFIED
BITUMEN ROOFING MEMBRANE
FULLY ADHERED 80 MIL PVC FLEECE BACK
ROOFING SYSTEM AND ADHERED 60 MIL
PVC FLASHING SYSTEM
EXISTING NAILED BASE
SHEET
ESCUTCHEON PLATE
STAINLESS STEEL FASTENERS WITH
NEOPRENE WASHERS 8" O.C.
STAINLESS STEEL CLEAT
EXISTING WALL FLASHING WITH FOIL FACING
REMOVED
EXISTING SPLIT FACE BLOCK
EXISTING PARAPET WALL
4" MIN.
STAINLESS STEEL CLEAT
EXISTING PARAPET WALL
PREFINISHED ALUMINUM COPING COVER WITH
SEALED JOINT LAPS
S.S. FASTENERS WITH NEOPRENE
WASHERS AT 8" O.C.
PREFINISHED ALUMINUM COPING
WITH SEALED LAPS
ADHERED 60 MIL PVC
FLASHING SYSTEM WITH
LIGHTWEIGHT VENTS AT 18' O.C.
CLEANED EXISTING MODIFIED
BITUMEN ROOFING MEMBRANE
FULLY ADHERED 80 MIL PVC FLEECE BACK
ROOFING SYSTEM
EXISTING NAILED BASE
SHEET
EXISTING WALL FLASHING WITH
FOIL FACING REMOVED
ADHERED 60 MIL PVC
FLASHING SYSTEM
EXISTING TAPERED LIGHTWEIGHT CONCRETE
INSULATION SYSTEM
M
IN
M
IN
EXISTING LARGE EXHAUST FAN
S.S. FASTENERS WITH
NEOPRENE WASHERS
EXISTING CANT STRIP
ADHERED 60 MIL PVC FLASHING SYSTEM
CLEANED EXISTING MINERAL SURFACED
MODIFIED BITUMEN ROOFING MEMBRANE
EXISTING TAPERED
LIGHTWEIGHT CONCRETE
INSULATION SYSTEM
EXISTING NAILED BASE
SHEET
FULLY ADHERED 80 MIL FLEECE
BACK PVC ROOFING SYSTEM
EXISTING WOOD CURB
EXISTING WALL FLASHING
WITH FOIL FACING REMOVED
FULLY ADHERED 80 MIL FLEECE
BACK PVC ROOFING SYSTEM
ADHERED 60 MIL PVC FLASHING
SYSTEM
EXISTING TAPERED LIGHTWEIGHT CONCRETE
INSULATION SYSTEM
CLEANED EXISTING MINERAL SURFACED
MODIFIED BITUMEN ROOFING MEMBRANE
REINFORCED 2-PART
LIQUID APPLIED FLASHING
CLEAN EXIST. EYEBROW SURFACE AND APPLY
REINFORCED WATERPROOFING/ ROOF COATING
EXISTING MODIFIED
BITUMEN MEMBRANE
EXISTING FLASHING
MEMBRANE
EXISTING PREFINISHED
ALUMINUM COUNTERFLASHING
PREMIUM SILICONE SEALANT
EXISTING TERMINATION BAR
WITH FASTENERS 8" O.C.
M
IN
M
IN
EXISTING LARGE EXHAUST FAN
S.S. FASTENERS WITH
NEOPRENE WASHERS
EXISTING CANT STRIP
ADHERED 60 MIL PVC FLASHING
SYSTEM
CLEANED EXISTING MINERAL SURFACED
MODIFIED BITUMEN ROOFING MEMBRANE
EXISTING NAILED BASE SHEET
FULLY ADHERED 80 MIL FLEECE
BACK PVC ROOFING SYSTEM
EXISTING WOOD CURB
EXISTING WOOD DECK
EXISTING RIGID INSULATION SYSTEM
EXISTING WALL FLASHING
WITH FOIL FACING REMOVED
EXISTING ROOF HATCH, CLEAN, PRIME, PAINT
TWO COATS, AND RAISED AS REQUIRED.
FULLY ADHERED 80 MIL FLEECE
BACK PVC ROOFING SYSTEM
ADHERED 60 MIL PVC FLASHING SYSTEM
MANUFACTURER'S WALKPAD
CLEANED EXISTING MINERAL SURFACED
MODIFIED BITUMEN ROOFING MEMBRANE
EXISTING WALL FLASHING
WITH FOIL FACING REMOVED
EXISTING WOOD DECK
EXISTING RIGID
INSULATION SYSTEM
CLEANED EXISTING MINERAL SURFACED
MODIFIED BITUMEN ROOFING MEMBRANE
FULLY ADHERED 80 MIL FLEECE
BACKED PVC MEMBRANE
ADHERED 60 MIL PVC FLASHING SYSTEM
LIQUID APPLIED REINFORCED FLASHING
STAINLESS STEEL DRAW BAND
EXISTING STAINLESS
STEEL UMBRELLA
CUT OUT AND REPLACE
WITH SILICONE SEALANT
EXISTING WOOD DECK
EXISTING RIGID
INSULATION SYSTEM
SCALE: 3" = 1'-0"
1 VTR DETAIL (TYP.)
A500 0 3'' 6'' 9'' SCALE: 3" = 1'-0"
2 SCUPPER DETAIL (ROOF B)
A500 0 3'' 6'' 9'' SCALE: 3" = 1'-0"
3 PARAPET WALL DETAIL (ROOF B)
A500 0 3'' 6'' 9''
SCALE: 3" = 1'-0"
4 EXHAUST FAN DETAIL (ROOF B)
A500 0 3'' 6'' 9'' SCALE: 3" = 1'-0"
5 GOOSENECK CONDUIT DETAIL
A500 0 3'' 6'' 9'' SCALE: 3" = 1'-0"
6 EYEBROW WALL BASE DETAIL
A500 0 3'' 6'' 9''
SCALE: 3" = 1'-0"
7 EXHAUST FAN DETAIL
A500 0 3'' 6'' 9'' SCALE: 3" = 1'-0"
8 ROOF HATCH DETAIL
A500 0 3'' 6'' 9'' SCALE: 3" = 1'-0"
9 PIPE PENATRATION DETAIL
A500 0 3'' 6'' 9''
| 2025-08-13T12:41:51-0400 | |