16-Attachment E - Senior Center Roof Plans - A01-G100.pdf
PDF 3 MB Posted
- Attached to
- Senior Center Roof Project
- Solicitation number
- IFB-032-26-KM
- Issued by
- Leon County, Florida
About this file
This is a roof repair plan document prepared by MLD Architects for the City of Tallahassee, Florida, detailing specifications for the Senior Center Building roof repairs located at 1400 N. Monroe Street, Tallahassee, Florida 32303. The project scope includes cleaning and patching the existing mineral surface low slope roofing system, removing parapet wall base flashing, and fully adhering an 80 mil polyvinyl chloride (PVC) fleece backed cap sheet roofing with a high solar reflectance index (SRI) and 60 mil PVC flashing membrane system. The work also encompasses installation of new prefinished aluminum parapet coping with sealed joint caps over existing stone coping, installation of new PVC clad scuppers, and replacement of damaged skylight(s) at the Annex location as indicated on the plans. The project is designed to comply with the Florida Building Code (8th Edition, 2023), Florida Accessibility Code, Florida Existing Building Code, and National Electrical Code (2020 Edition), with the roofing system to provide a roofing manufacturer's 20-year non-delegated labor (NDL) system warranty.
The permit set plans include a title sheet, roofing schedule and notes, roof plan, and detailed specifications across multiple drawing sheets (A000, A100, A500, A501, A700). Contractors must provide documentation verifying that all exterior envelope components meet product approval requirements per Florida Statute 553.842 and comply with roofing manufacturer's installation recommendations. The drawings are dated August 12, 2025, and were prepared by MLD Architects, a building envelope consultants firm based in Tallahassee. These documents are the proprietary property of MLD Architects and are intended for use specifically on this project; electronic distribution and reproduction for other projects are not authorized without written approval from the project architect.
View the file
Other files
Show all 21
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
AR96289
BUILDING ENVELOPE
211 JOHN KNOX RD, SUITE 105
TALLAHASSEE, FL 32303
PH: (850) 385 9200
MLDARCHITECTS.COM
CONSULTANTS
G100
PERMIT SET
PROJ. NO.
DATE
DRAWN
CHECKED
APPROVED
REVISION
REVISION DATE
171824
08/12/2025
KR
RB
JS
TITLE SHEET
TA
LL
A H
A
SS
EE
, F
LO
RI
D A
SE
N
IO
R
C
EN
TE
R
BU
IL
D
IN
G R
O O
F
RE
PA
IR
S
C
ITY
O F
TA
LL
A H
A
SS
EE
N
G100 TITLE SHEET
A000 A100 A500 A501 A700
ROOFING SCHEDULE & NOTES
ROOF PLAN
DETAILS
DETAILS
Layout
1400 N. MONROE STREET
TALLAHASSEE, FLORIDA 32303
DRAWING INDEX
SENIOR CENTER BUILDING ROOF REPAIRS
CITY OF TALLAHASSEE
TALLAHASSEE, FLORIDA
BUILDING AND FIRE CODES
THESE DRAWINGS AND SPECIFICATIONS ARE THE CONFIDENTIAL AND PROPRIETARY PROPERTY OF MLD ARCHITECTS AND SHALL NOT BE COPIED OR REPRODUCED WITHOUT WRITTEN AUTHORIZATION. THE CONTRACT DOCUMENTS WERE PREPARED FOR THE USE ON THIS SPECIFIC SITE IN CONJUNCTION WITH ITS ISSUE DATE AND ARE NOT SUITABLE FOR USE ON A DIFFERENT SITE OR AT A LATER TIME. USE OF THESE DRAWINGS FOR REFERENCE OR EXAMPLE ON ANOTHER PROJECT REQUIRES THE SERVICES OF PROPERLY LICENSED ARCHITECTS AND ENGINEERS. REPRODUCTION OF THE
CONTRACT DOCUMENTS FOR REUSE ON ANOTHER PROJECT IS NOT AUTHORIZED.
ELECTRONIC DISTRIBUTION OF THESE DOCUMENTS IS NOT AUTHORIZED, UNLESS SPECIFICALLY APPROVED BY PROJECT
ARCHITECT IN WRITING.
VICINITY MAP
AERIAL PHOTO
DISCLAIMER
SCOPE OF WORK
FLORIDA BUILDING CODE (FBC), 8TH EDITION (2023)
FLORIDA ACCESSIBILITY CODE (FAC), 8TH EDITION (2023)
FLORIDA EXISTING BUILDING CODE (FBC-EB), 8TH EDITION (2023)
FLORIDA FUEL GAS CODE (FBC-FG), 8TH EDITION (2023)
FLORIDA MECHANICAL CODE (FBC-M), 8TH EDITION (2023)
FLORIDA PLUMBING CODE (FBC-P), 8TH EDITION (2023)
FLORIDA FIRE PREVENTION CODE (FFPC), 8TH EDITION (2023)
NATIONAL ELECTRICAL CODE (NEC), 2020 EDITION
FLORIDA PRODUCT APPROVAL:
CONTRACTOR SHALL MAKE AVAILABLE TO THE BUILDING INSPECTOR DOCUMENTATION NECESSARY TO VERIFY THAT ALL EXTERIOR ENVELOPE COMPONENTS REQUIRING PRODUCT APPROVAL PER FS 553.842 ARE IN COMPLIANCE WITH
PRODUCT APPROVAL INSTALLATION REQUIREMENTS.
BRIEFLY AND WITHOUT FORCE AND EFFECT UPON THE CONTRACT DOCUMENTS, THE WORK OF THE CONTRACT CAN BE
SUMMARIZED AS FOLLOWS:
WORK TO INCLUDE: CLEANING AND PATCHING THE EXISTING MINERAL SURFACE LOW SLOPE ROOFING SYSTEM, REMOVING THE PARAPET WALL BASE FLASHING, FULLY ADHERING A HIGH SOLAR REFLECTANCE INDEX (SRI), 80 MIL POLYVINYL CHLORIDE (PVC) FLEECE BACKED CAP SHEET ROOFING AND 60 MIL PVC FLASHING MEMBRANE SYSTEM.
COMPLY WITH THE CURRENT FLORIDA BUILDING CODE (FBC) AND THE ROOFING MANUFACTURER'S RECOMMENDATIONS TO PROVIDE A ROOFING MANUFACTURER'S 20-YEAR NDL SYSTEM WARRANTY. ALSO INCLUDE INSTALLING NEW PREFINISHED ALUMINUM PARAPET COPING WITH SEALED JOINT CAPS OVER THE EXISTING STONE COPING CAP.
INSTALLING NEW PVC CLAD SCUPPERS. AT ANNEX ONLY REPLACE THE DAMAGED EXISTING SKYLIGHT WHERE INDICATED.