20-Attachment E - Senior Center Roof Plans - A05-A501.pdf
PDF 536 KB Posted
- Attached to
- Senior Center Roof Project
- Solicitation number
- IFB-032-26-KM
- Issued by
- Leon County, Florida
About this file
This is a permit set of architectural roof repair plans for the City of Tallahassee Senior Center building roof repairs project. The plans detail the complete roof replacement specification for the facility located at 1400 N Monroe Street, Tallahassee, Florida. The project scope includes cleaning and patching the existing mineral surface low slope roofing system, removing parapet wall base flashing, and installing a fully adhered 80 mil polyvinyl chloride (PVC) fleece backed cap sheet roofing system with a 60 mil PVC flashing membrane system. The plans incorporate nine detailed specifications, including skylight curb details, vent termination roof (VTR) details, wall base flashing, roof drain details, edge details, parapet wall details, roof gutter edge details, and transition details. All specifications are drawn to scale of 3 inches equals 1 foot and indicate required materials such as prefinished aluminum counterflashing, premium silicone sealant, stainless steel components, reinforced liquid-applied flashing, and manufactured components with factory-installed fiberglass insulation.
The plans specify the use of high solar reflectance index (SRI) materials for the roofing system and require adherence to roofing manufacturer's requirements throughout installation. Existing structural elements including wood decking, rigid insulation systems, mineral surfaced modified bitumen roofing membranes, and masonry walls will be retained where applicable. The project requires cleaning and priming of existing components, installation of new metal basket strainers, and protection of exposed piping with premium acrylic coating systems. The permit set was prepared by consultants in Tallahassee, Florida, with project number 171824, dated August 12, 2025, and reviewed by multiple approval parties.
View the file
Other files
Show all 21
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
CONSULTANTS
A501
PERMIT SET
PROJ. NO.
DATE
DRAWN
APPROVED
REVISION
REVISION DATE
08/12/2025
DETAILS
CHECKED
171824
KR
RB
JS
CONSULTANTS
TA
LL
A H
A
SS
EE
, F
LO
RI
D A
SE
N
IO
R
C
EN
TE
R
BU
IL
D
IN
G R
O O
F
RE
PA
IR
S
C
ITY
O F
TA
LL
A H
A
SS
EE
VERIFY V
ER
IF
Y
EXISTING TAPERED LIGHTWEIGHT
CONCRETE INSULATION SYSTEM
FULLY ADHERED 80 MIL FLEECE
BACK PVC ROOFING SYSTEM
EXISTING GRANULATED
MODIFIED BITUMEN ROOFING
MEMBRANE
ADHERED 60 MIL PVC FLASHING
SYSTEM
PRE-MANUFACTURED SKYLIGHT
CURB WITH FACTORY INSTALLED
FIBERGLASS INSULATION MANUFACTURER'S CURB MOUNTED
DOUBLE DOME SKYLIGHT
2X PT NAILER
EXISTING NAILED BASE SHEET
3/8" GYPSUM GOARD ON LIGHT
GAUGE METAL STUDS
EXTEND EXISTING V.T.R. PIPING TO BE
MINIMUM 10" ABOVE FINISHED ROOF
FULLY ADHERED 80 MIL FLEECE BACK
PVC ROOFING SYSTEM
MANUFACTURER'S PVC BOOT
FLASHING PRIME AND PAINT
EXPOSED AREA OF
PIPE WITH PREMIUM
ACRYLIC COATING
SYSTEM TO PROTECT
FROM U.V.
S.S. DRAW BAND
CLEANED EXISTING MINERAL SURFACED
MODIFIED BITUMEN ROOFING MEMBRANE
REINFORCED LIQUID APPLIED FLASHING
EXISTING WOOD DECK
EXISTING RIGID
INSULATION SYSTEM
NEW METAL BASKET STRAINER
PRIME AND PAINT 2 COATS
EXISTING ROOF DRAIN ANCHORED
TO STRUCTURAL ROOF DECKING.
CLEAN PRIME AND PAINT
S.S. BOLTS IN
CLAMPING RING
EXISTING STRUCTURAL ROOF
DECK
30"x30" MIN. LEAD SHEET FLASHING SET
IN A BED OF MASTIC. MALLET TO FIT AND
EXTENDED 1" MIN. INTO DRAIN BOWL.
ADHERED 60 MIL PVC FLASHING SYSTEM
W/ HEAT WELDED LAPS AND SEAMS
FULLY ADHERED 80 MIL FLEECE BACK
PVC ROOFING SYSTEM
CLEANED EXISTING MINERAL SURFACED
MODIFIED BITUMEN ROOFING MEMBRANE
EXISTING RIGID INSULATION SYSTEM
CLEANED EXISTING MINERAL SURFACED
MODIFIED BITUMEN ROOFING MEMBRANE
ADHERED 60 MIL PVC FLASHING SYSTEM
FULLY ADHERED 80 MIL FLEECE
BACKED SINGLY PLY PVC MEMBRANE
PREFINISHED ALUMINUM COUNTERFLASHING
WITH PREMIUM SILICONE SEALANT
TERMINATION BAR FASTENED AT 8" O.C.
EXISTING MASONRY WALL
EXISTING WOOD DECK
EXISTING WALL FLASHING
WITH FOIL FACING REMOVED
EXISTING RIGID INSULATION SYSTEM
FULLY ADHERED 80 MIL FLEECE
BACKED SINGLY PLY MEMBRANE
ADHERED 60 MIL PVC FLASHING SYSTEM
CLEANED EXISTING MINERAL SURFACED
MODIFIED BITUMEN ROOFING MEMBRANE
EXISTING WOOD DECK
PVC CLAD EDGE METAL FLASHING
PREFINISHED ALUMINUM GUTTER
AND DOWNSPOUT ATTACHED AT
TOP MIDDLE AND BOTTOM
EXISTING RIGID INSULATION SYSTEM
EXISTING BRICK COLUMN
EXISTING DECK
METAL BASKET STRAINER
PRIME AND PAINT 2 COATS
EXISTING ROOF DRAIN ANCHORED
TO STRUCTURAL ROOF DECKING.
CLEAN PRIME AND PAINT
S.S. BOLTS IN CLAMPING RING
CLEANED EXISTING MINERAL
SURFACED MODIFIED BITUMEN
ROOFING MEMBRANE
TWO PART REINFORCED LIQUID
APPLIED FLASHING
EXISTING FLASHING WITH FOIL
FACED TO BE REMOVED
EXISTING EDGE METAL
FULLY ADHERED 80 MIL FLEECE
BACKED SINGLY PLY PVC MEMBRANE
ADHERED 60 MIL PVC FLASHING SYSTEM
W/ HEAT WELDED LAPS AND SEAMS
TERMINATION BAR FASTENED AT 8"
O.C. WITH PREMIUM SILICONE SEALANT
CLEANED EXISTING MINERAL SURFACED
MODIFIED BITUMEN ROOFING MEMBRANE
FULLY ADHERED 80 MIL FLEECE
BACKED PVC MEMBRANE
ADHERED 60 MIL PVC FLASHING SYSTEM
PVC CLAD EDGE METAL FLASHING WITH
CONTINUOUS CLEAT
EXISTING WOOD DECK
EXISTING RIGID
INSULATION SYSTEM
CLEANED EXISTING MINERAL SURFACED
MODIFIED BITUMEN ROOFING MEMBRANE
ADHERED 60 MIL PVC FLASHING SYSTEM
FULLY ADHERED 80 MIL FLEECE
BACKED SINGLY PLY PVC MEMBRANE
TERMINATION BAR FASTENED AT 8" O.C.
WITH PREMIUM SILICONE SEALANT
EXISTING COPING STONE
EXISTING WOOD DECK
REINFORCED 2-PART
LIQUID APPLIED FLASHING
EXISTING ALUMINUM
EDGE METAL
EXISTING WALL FLASHING
WITH FOIL FACING REMOVED
EXISTING WALL FLASHING
WITH FOIL FACING REMOVED
EXISTING RIGID INSULATION SYSTEM
ADHERED 60 MIL PVC FLASHING SYSTEM
CLEANED EXISTING MINERAL SURFACED
MODIFIED BITUMEN ROOFING MEMBRANE
ADHERED 60 MIL PVC FLASHING SYSTEM
FULLY ADHERED 80 MIL FLEECE
BACKED SINGLY PLY PVC MEMBRANE
PREFINISHED ALUMINUM COUNTERFLASHING
WITH PREMIUM SILICONE SEALANT
TERMINATION BAR FASTENED AT 8" O.C.
EXISTING COMPOSITE ROOF PANEL
EXISTING RIGID INSULATION SYSTEM
REINFORCED APPLIED FLASHING
EXISTING WOOD DECK
SCALE: 3" = 1'-0"
2 SKYLIGHT CURB DETAIL (ROOF B)
A501 0 3'' 6'' 9''SCALE: 3" = 1'-0"
1 VTR DETAIL (TYP.)
A501 0 3'' 6'' 9''
SCALE: 3" = 1'-0"
4 ROOF DRAIN DETAIL (ROOF D)
A501 0 3'' 6'' 9''
SCALE: 3" = 1'-0"
3 WALL BASE FLASHING
A501 0 3'' 6'' 9''
SCALE: 3" = 1'-0"
7 ROOF GUTTER EDGE DETAIL
A501 0 3'' 6'' 9'' SCALE: 3" = 1'-0"
8 ROOF DRAIN DETAIL
A501 0 3'' 6'' 9''
SCALE: 3" = 1'-0"
5 EDGE DETAIL
A501 0 3'' 6'' 9'' SCALE: 3" = 1'-0"
6 PARAPET WALL DETAIL
A501 0 3'' 6'' 9''
SCALE: 3" = 1'-0"
9 TRANSITION DETAIL
A501 0 3'' 6'' 9''
| 2025-08-13T12:41:17-0400 | |
| Jerry A Scott |
File details come from the government source that posted it. Updated .